Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BERNARD BLK 3 LT I-1A
Bernard Block 3 Lot I -1A #060-321-15 umber P111° Dotty- Z- /3 .x1.27 2312 1 '6PW 2a rre : i`^ifigri rg G;rOIJC A STI LS. STS 5`+.119 DELI 57.67 59.69 CCI RTI 7x.41 7651 ODS 134.06 Mfg 134911 CO3 17.19 MT3 6795 CO4 127.71 MT+ 126.03 N3.5215 F. ROOIMD S/4; TRACT F-1 C THE COITRICIOR EXCAIUTFC T11E oa ARSE SST1Fa T! HOLISC ma won Nor Laa mc COOLO ROT FOC A WIC 'IMIC OR ISADMILLO or Am Mt IT a SSLLVC TUT OILY A dr PERFROL a MFT talo T; romanoa aFTP THS FIAT* Mit SIRS. ALL OW PMYIC !l! ASYIODico. 8 q 19.611 3943 21.31- 29.' 2327 22.66 61.23 75.61 32.>7 32.95 ROAR U.46 LVt 711 INOLL AT I3E£ ATSq� SOIL L LOGC A /TRFA7A6'J/f b mono Miffing.. or rpi ©reap OMR A/FalAt LOC4701 OF remota MEM fl 1 1 1 f GARNESS ENGIN sumo GONSIU.aIn* a W 6rd 1W1 MP • 01100.11. Al Imb •q PREPMSD FOR: NATHAN GUBSER Tre 059CSW'llolk BERNARD S/D; BLOCK 3, LOT WIT OF a AS—BUILT DRAWING OF KEW S at Mt 1A J.L. TIC SYSTEM 10/25/2011 e Pang onP11 AMA s AS -BUILT DRAWING mail Knee 060-321-15 TOP ov TAN AT RtET . 94.01 S1! Ta a MAK O At OUTLET - 94.0e NEW 1500 GALLOP! SEPTIC TANK Mtn OF OtPC - 1430 TOP Cr SIO 0370 i.�aak 0777011 OF WSW, - 01.70 MAINE ELEM ON OF BOTIO11 OF MIIIHD1.¢ . 0490 (OKeJ GLIBNESS ENGIN sat catstnnwT8 a, fpr 1.101-m rpW% •.eros a *Rat PREMED _ - NATHAN GUBSER BERNARD S/0; BLOCK 3, LOT TYPE OF *Opti PROFILE AS BUILT DRAWING SEPTIC SYSTEM 10/25/2011 GARNESS ENGINEERING GROUP, Ltd. June 26, 2013 CONSULTANTS & GENERAL CONTRACTORS Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Waiver Request From Well to Septic Service Line on Bernard Subdivision; Block 3, Lot I -1A, (SW080255) To whom it may concern: A home has been recently constructed on the referenced property. During the construction a new sewer service line was installed to from the new construction to the existing private sewer system. It is assumed now that the sewer service line has an approximate separation distance of 15 feet to the existing well. According to the owner (Nathan Gubser), he had a meeting with MOA employees; Jay Crewdson, Jeff Poet, & Deb Wockenfuss in which they stated that a possible waiver could be issued if he had; • A letter from the installer/contractor stating that the sewer service line was glued at all joints (see attached letter from Curt Whitters). • The pitless adapter needs to be sealed with bentonite (see attach quote to perform work). At this time we request that your department issue a 15' waiver from the well to the sewer service line. We are unaware of any adverse impacts this waiver would have on adjacent wells or septic systems. If you have any qus ions, please contact us at 337-6179. Thank you for your assistance. Je Pres P.E., M.S. 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com WED/JUN/26/2013 15:52 Re: 8182 Stewart Mountain Dr. Eagle River, AK 99577 To Whom It May Concern, FAX No. P. 003 The purpose of this letter is to acknowledge that while the main sewer line from the house cleanout to the septic was installed so that it does encroach within 25' of the existing well on this property, I affirm that this line was glued at all joints. Sincerely, Curt Whitters — Whitters Excav ' (907) 696-0822 SC.. b_26_ LS suaMIMI 'NICE - ARCTIC PUMP & WELL INC. Jim Sullivan, CPI PO Box 770197 Eagle River, AK 99577 (907) 688-2510 (907) 258-2510 (907) 745-2510 aew(gei.net Pump Installation Log Well Drilling Permit Number: SW080255 Parcel Identification Number: 060-321-15 Date of Issue: 12-16-08 Arctic Pump & Well, Inc. Page 1 of 1 Legal Description:Bernard Lot:1-la Block:3 Property Owner Name & Address: Bernard Stewart 8182 stewart Mt Dr Facile River ATC 00577 Pump Installation Date: 9-18-09 Pump Intake Depth Below Top of Well Casing:199 Feet Pump Manufacturer's Name: Franklin Pump Mode1:20SDQ-1.5 Pump Size:1.5 hp Pitless Adapter Burial Depth: feet Pitless Adapter Manufacturer's Name: Pitless Adapter Installer: UK Well Disinfected Upon Completion? Yes Method of Disinfection: Chlorine Comments: Pump Installer Name: Arctic Pump & Well, Inc. Arctic Pump & Well, Inc. Page 1 of 1 (tallith Orating log by DOC CO. dba SULLIVAN WATER WELLS P.O. BOX 670272, CHUGIAK, ALASKA 99567 • TELEPHONE 688-2759 OWNER OF LAND. tileAdJ.41C- `% s Eta..:4 ADDRESS. LEGAL DESCRIPTION. /3 Et4✓ 1:00 -%i Di d.. i .4 DATE: r v PERM IT NUMBIER:,✓: C)2253— Date of Issue/.l -tL -t2- TAX IDENTIFICATION NUMBER- a60 - - /J Is welt located at approved permit location? y 15 No Method of Drilling: aai rotary LI cable tool Depth of well. %U' Casing Type .5 rC/ Wall Thickness •:1S L' inches II Diameter b inches, depth 6 €/ feet Liner Type: ,;(11ivi-% ?t/rW i i iD3Jdj= Casing Stickup Above Ground. Static Water Level. 1// Recover Rate• .ei J gpm Method of Testing' feet feet Well Intake Opening Type: open end 3 open hole ❑ Screened; Start feet Stopped ❑ Perforations Start fe_ Stopped Grout Type- $r a .' "'° t; gaVolu!fi d me Depth: from 0 feet, to feet feet ;It Weil Disinfected Upon Completion? 04s ❑ No Method of Disinfection: a%.ddi 3-6 I ;42M feet Comments: BOFC HOLE DATA DEPTH From To 0 v2 4 !'1 /7 /9, 7S' //2 /102 ;13,2 O 13t.JL /C.1cJ%O 554.)o 64r4.t S 4 S>. 344.1& 1%,et9-1'e dc4.*€, s- se 4f -cast ' .js_.9 A Lac eY</it 41 Al Act:e a_ 64,11) €✓aC)CAC a5 3 deer: RAt Driller's Name z,)AtE 't•-) ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. Matsu Borough: Department of Environmental Conservation. 6'd 69LZ 889 L06 slleM ae}eM uenlllnS dLo:co 60 170 oe❑ cocci > co LLI J LL 0 Q 00 CV °O 0 Z cko J0 vo ..SeQ Poo se Ara • 0 wgRT 44 IA At 24739 o kF SsoU 550. \ N CO Gravel driveway — — Rock wall (typ) 2 Story Frame Shop 10 ryv 58. StoryQ41.Obra e Nouse ck //® LOT I -1A 0) 4. 0 L 0 F 1 112.5 LOT 1-1B \?s 1.22,\ �, • 9ti• ••• •• \ \ "0 83541 yr •\ • • •• \• \ SCALE 1"= 40' EASEMENT'S OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED PLAT ARE NOT SHOWN HEREON. Fb 12-7, pg 65 N89°56'30"E 310.41 20' ALLEY d� of .••4611 d U� • • • . Y.Y. S,t! • !!< .: cc. Fred Walatka • o 0,0 C V•. No. 3255-5 .' � t• \ • REVISED 6-05-13 ADDED CLEANOUT ({rV' AS -BUILT NO CORNERS SET THIS DATE I hereby certify that I have performed a Mortgagee's inspection of the following described property: LOT I -1A, BLOCK 3 BERNARD SUBDIVISION Anchorage Recording Precinct, Alaska, and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Anchorage, Alaska this 1st day of November 2012 FRED WALATKA & ASSOCIATES Engineers and Surveyors BE (907-248-1666) On -Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP111045 Tax Code Number: 06032115000 Work Type: WellSeptic Upgrade Permit Effective Dates: May 05, 2011 to May 04, 2012 Design Engineer: GARNESS ENGINEERING GROUP LTD Subdivision: BERNARD Site Legal Address: BERNARD BLK 3 LT I -1A G:0254 Owner/Address: GUBSER NATHAN D & KARISSA L PO BOX 671341 CHUGIAK AK 995670000 Site Mailing Address: 8182 STEWART MOUNTAIN DR, Eagle River Lot Size in Sq Ft: 65630 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: The entire subsurface disposal field is not within 30 feet of a percolation test. The Engineer needs to do an additional percolation test prior to the construction of the septic field. Please submit stamped and signed results with the As -built Inspection Report. If the results require a design change, construction of the system will stop pending On -Site review and approval. Received By: �c Issued By: /� t' Date: Date: 3 i Municipality of Anchorage P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 http://www.muni.orq/Onsite Development Services Department On -Site Water and Wastewater Program Department * * * * VARIANCE/WAIVER REVIEW * * * * WR#: OSP111046 HA#: Permit#: OSP111045 PID#: 060-321-15 Legal Description: Bernard, Block 3, Lot I -1A Engineer: GEG Applicant: Nathan Gubser Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 0.0 feet. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: Date: 5/5/11 Approved by:,/ *� Name of Reviewer Rec#: 073325 Amount: $200.00 Date Paid: 5/2/2011 **** VARIAN C E/WAIVER REVIEW **** Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON—SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 060-321-15 Property owner(s) NATHAN GUBSER Day phone 317-1975 Mailing address 8182 STEWART MOUNTAIN DRIVE *EAGLE RIVER, AK 99577 Site address Zip Code 99516 Legal description (Sub'd, Block & Lot) BERNARD S/D: BLOCK 3, LOT I -1A Legal description (Township, Section & Range) N/A Lot Size Sq.Ft. Number of Bedrooms 4 THIS APPLICATION IS FOR (®aII that apply): THIS APPLICATION IS AN: Absorption Field Initial ❑ Septic Tank ® Upgrade Holding Tank n Renewal n Privy Private Well Water Storage THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: LOT LINE WAIVER I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. Permit1Rush Fees: 73 Waiver Fees: Date of Payment: _'� " r 1 Date of Payment:•ID- Receipt Number: 0 1 Receipt Number: (Rev. 11/05) U 1 377);-_Y:)--- t-,-)5C 3c T) GAR.] ESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS April 22, 2011 REVISED SW080255 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Revised Septic Design Upgrade for Bernard Subdivision; Block 3, Lot I -1A, (SW080255) To whom it may concern: The expired sewer permit (SW080255) for this property called for the installation of a Quanics Aerocell system. The new property owner would like to install a conventional septic system and is willing to abandon a portion of the round -about driveway in order to achieve this. We are now proposing to install a 1250 gallon septic tank and a dual 5 -wide trench type drainfields. One test hole was excavated on the property previously and a second confirmation test hole was recently excavated which we were not present for. The excavator did however install a monitoring tube to a depth of 13.5 feet and left the hole benched to a depth of 6 feet. The stockpile was inspected and it appeared to reflect the same as TH #1. The drainfield will be designed around the 30 foot radii of these test holes. Comments regarding the design are summarized as follows: 1. SOILS: See the attached logs which show the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system. 4. TOPOGRAPHY: As can be seen on the attached design drawing the average topography in the area below the drainfield is approximately 5-10% running south to north. In short, there are no slope concerns with this installation. 5. LOT LINE WAIVER: Due to site constraints, we are requesting a 01+ lot line waiver from the north lot line to the proposed drainfield. There are no neighboring drainfields with in 10 feet of the proposed waiver. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any qi4 estions, please contact us at 337-6179. Thank you for your assistance. 11 V ,5.iacemiy9 Jeffrey A. gapess, P.E., M.S. Presid nt 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com PROPOSED SEPTIC SYSTEM \wqR' Moo / Nr / TH#1\�N\O / i TH#2 (CON�FIRMATIO / / BERNARD S/D; TRACT F-1 42411,7 TRAILER A r 1 EXISTING HOUSE 100° PROPOSED WELL RADIUS \ / \� til /I I , BERNARD S/D; BLOCK 3, 1-1B / [SEPTIC AREA-) BERNARD S/D; TRACT E-1 / vik OP°Ssoizrx � w \ / \ \ // \\ \ / \ \ / \ N \ — / 7 \ \ \ \ \ / \ \ I \ \ \ 100° WELL RADIUS \ \ \\ (PROPOSED) / SEPTIC AREA (PROPOSED) BERNARD S/D; BLOCK 3, LOT 3A BERNARD S/D; BLOCK 3, LOT 9 PGP \I BERNARD BLOCK 3, LOT/10 f\ / GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS 701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507 • PHONE (907)337-6179 • FAX (907)338-3246 WEBSITE: www.gamessengineering.eom PREPARED FOR: NATHAN GUBSER PHONE NUMBER: 317-1975 LEGAL DESCRIPTION: BERNARD S/D; BLOCK 3, LOT I -1A TYPE OF WORK: SITE PLAN DESIGN (Rev. 01/05) PAGE NUMBER: 1 OF 3 DRAWN BY: PNB DATE: 4/27/11 SCALE: DESIGN CRITERIA: 1.0 GPD 2 FEET NUMBER OF BEDROOMS: 4 GALLONS PER DAY (GPD): 600 PERCOLATION RATE/S: <1 MIN/IN PROPOSED APPLICATION RATE: MINIMUM DRAINFIELD SQ.FT.: 600 DRAINFIELD DESIGN: MAXIMUM DEPTH: 9 FEET WIDTH: 5 FEET LENGTH: 2 ® 60=120FEET M.O.A. APPROVED SAND FILTER: EFFECTIVE: 0.5 FEET REDUCTION FACTOR: N/A ACTUAL SQ.FT.: 600 rn 13' SECTION LINE EASEME` "4".. cn /.;� or RESERVE DESIGN CRITERIA NUMBER OF BEDROOMS: 4 GALLONS PER DAY (GPD): 600 PERCOLATION RATE/S: <1 MIN/IN PROPOSED APPLICATION RATE: *5.0 GPD MINIMUM DRAINFIELD SQ.FT.: 120 *ADVANCED TREATMENT RESERVE DRAINFIELD DESIGN: MAXIMUM DEPTH: 9 FEET WIDTH: 5 FEET LENGTH: 24 FEET M.O.A. APPROVED SAND FILTER: 2 FEET EFFECTIVE: 0.5 FEET REDUCTION FACTOR: N/A ACTUAL SQ.FT.: 120 GEG, Ltd. HAS A 7 PAGE SPECIFICATION LETTER THAT PERTAINS TO THIS DESIGN. TO OBTAIN A COPY OF THE LETTER CONTACT GEG. BY PROCEEDING FORWARD WITH THIS INSTALLATION, THE ENGINEER, WELL DRILLER, CONTRACTOR AND PROPERTY OWNER AGREE THAT THEY HAVE READ THESE SPECIFICATIONS AND AGREE TO ACCEPT THE TERMS AND CONDITIONS OUTLINED. NOTE: THE CONTRACTOR SHALL HAVE THE NORTH LOT LINE, WEST EASEMENT, AND WELL RADII FLAGGED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION. ORTION OF DRIVEWAY TO BE ABANDONED SFD BERNARD S/D; TRACT F-11 MT APPROXIMATE LOCATION OF EXISTING UNDOCUMENTED CRIB TO BE COMPLETELY ABANDONED / FLOW `� SPLITTER EXISTING 4 BEDROOM HOUSE L REQUIRE ADVANCED TREATMENT SCALE: 1" = 40' WELL \ \ W F-\ Z APPROXIMATE LOCATION OF EXISTING COMMUNITY WATER LINE, TO BE ABANDONED COMPLETELY \ \ 7 GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS 3701 E. TUDOR ROAD. SURE 101 • ANCHORAGE. AK 99507 • PHONE (907)337-6179 • FAX (907)338-3246 • WEBSRE: www.gomessengineering.com PREPARED FOR: NATHAN GUBSER PHONE NUMBER: 907-317-1975 PAGE NUMBER: 2 OF 3 LEGAL DESCRIPTION: BERNARD S/D; BLOCK 3, LOT I -1A TYPE OF WORK: REVISED DESIGN OF NEW SEPTIC SYSTEM (Rpm nl/n61 DRAWN BY: P.N.B DATE: 4/22/11 Awl. GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AX. 99507 • PHONE: (907)337-6179 • FAX: (907)338-3246 • WEBSITE: gameeeengtneering.co LEGAL DESCRIPTION: PERFORMED FOR: DEPTH (feet) 1 2 3 4 5 6 8 12 13 14 15 — 16- 17 — 18 — 19 — B.O.H. SOIL LOG - PERCOLATION TEST BERNARD S/D; BLOCK 3, LOT 11A BERNARD STEWART ORGANICS GP—GM 20 SOILS LOGGED BY: COMMENTS• TEST HOLE #1 SOIL CLASSIFICATIONS oo°°o606 /.1;d./ o°oo°oa0 ': ••.:• GW GP GM GC SW SP SM SC DATE: 10/14/2008 ORG ML CL OL MH CH OH DEPTH TO GROUNDWATER DATE DRY 10/14/08 DRY 10/17/08 Dal 4%29// DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 10/17/08 / Sp.O S.� P S FP SSR CEO PERCOLATION RATE TEST RUN BETWEEN 4.0 FT. AND 5.0 FT. <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES • NO JODY MAUS PERCOLATION TEST PERFORMED BY: KYLE MAUS PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS _ :;. 3701 E. TUDOR ROAD. SUITE 101 • ANCHORAGE. AK. 99507 • PHONE: (907)337-6179 • FAX: (907)335-3246 • WEBSRE: gomessengineering.eom LEGAL DESCRIPTION: PERFORMED FOR: SOIL LOG — PERCOLATION TEST BERNARD S/D; BLOCK 3, LOT I -1A NATHAN GU BSER 20 DATE: 4/21/11 TESTHOLE #2 (CONFIRMATION) LOGGED SOILS TO 6.5' THROUGH OPEN BENCH. NOT PRESENT DURING EXCAVATION. SOILS APPEARED CONSISTENT BASED UPON MATERIAL STOCKPILED ON SURFACE OF GROUND NEXT TO TESTHOLE. SOIL CLASSIFICATIONS e 00 00 0 00 0 ob •••• GW GP GM GC SW SP SM SC J% ORG ML CL OL MH CH OH DEPTH TO GROUNDWATER DATE DRY 4/21/11 Val 41 zq )ii �jTfrey GaRness: 9 CE—3 • '���p lila III' o pro f ession o DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) s'—D- 0N Q�� PERCOLATION RATE N/A (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 6.0 FT. AND 7.0 FT. A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES I 1 NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: N/A COMMENTS° VISUALLY APPEARED THE SAME AS TH#1 PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WA PE FORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: q 7,7/ MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SW080255 Legal Description: BERNARD BLOCK 3 LOT I -1A Design Engineer: 0855 GARNESS ENGINEERING GROUF Owner Name: BERNARD STEWART Owner Address: 8182 STEWART MOUNTAIN DRIVE EAGLE RIVER , AK 99577 - Date Issued: Dec 16, 2008 Expiration Date: Dec 16. 2009 Parcel ID: 060-321-15 Site Address: 8182 STEWART MOUNTAIN DRIVE Lot Size: 65630 SO. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: ❑✓ Disposal Field E Septic Tank ❑ Holding Tank fl Privy Q Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. A. Absorption field drain rock shall be no deeper than 8 feet maximum. B. This is a conditional approval. Unconditional approval is pending replacement of fax copy of maintenance agreement with an original. JC 1/8/09 Received By: Date: Issued By:avll/j 1, 1 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Elmore St. P.O. Box 196650 Anchorage, AK 99519-6650 www.clanchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: GEG Legal description: Bernard: Block 3; Lot I -1A ®Permit ❑C.O.S.A. ❑Inspection Report The attached paperwork has been reviewed and is being returned for the following reasons: 1. AWWTS Maintenance Agreement: Please provide an original of the AWWTS maintenance agreement bearing the owner's notarized signature. Name of reviewer: 4y Date: 12116/08 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.clanchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. Von -302 1— /5- BERNARD SBERNARD STEWART Day phone 8182 STEWART MOUNTAIN DRIVE • EAGLE RIVER. AK Property owner(s) Mailing address Site address Zip Code 907-694-3305 99577 Legal description (Sub'd, Block & Lot) BERNARD SUBDIVISION: BLOCK 3. LOT I -1A Legal description (Township, Section & Range) N/A Lot Size tG' 0 Sq.Ft. Number of Bedrooms 4 THIS APPLICATION IS FOR (® all that apply): Absorption Field Septic Tank Holding Tank Privy Private Well Water Storage THIS APPLICATION 1S AN: Initial Upgrade Renewal I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Gignoturc of property owner or outhorized-egent}- Permit/Rush Fees. Date of Payment: Receipt Number: (Rev. 11/05) serbC. LUF I I Lie, 0 4 /-9,s, Waiver Fees: Date of Payment: Receipt Number: GARNESS ENGINEERING GROUP Ltd. CONSULTANTS & GENERAL CONTRACTORS January 6, 2009 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Proposed Septic Upgrade for Bernard Subdivision; Block 3, Lot I -IA, To whom it may concern: The existing 4 bedroom house is served by a community water system that is being abandoned. We are proposing to install a private well. The existing septic system is undocumented and needs to be upgraded. We are proposing to install a 1500 gallon S.T.E.P. tank with Quanics controls/floats, a 650 Aerocell unit, and a 5 -wide trench type drainfield. One test hole was excavated on the property. The drainfield will be designed around the 30 foot radius of the test hole. Comments regarding the design are summarized as fol lows: 1. SOILS: Sec the attached logs which show the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system. 4. TOPOGRAPIIY: As can be seen on the attached design drawing the average topography in the area below the drainfield is approximately 5-10% running south to north. In short, there are no slope concerns with this installation. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any que j . ns, please contact us at 337-6179. Thank you for your assistance. Jeffr,., M.S. Pres NOTE: Attached it a site plan drawing, a design drawing, two detail drawings, and one soil log, which are all part of the design package for this septic system. (Contact G.E.G. Ltd. for 7 page construction specification letter.) 3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507-1259 Ph: (907) 337-6179 • Fax: (907) 338-3246 • Website: www.gamesscngineering.com >F5IIGN GRILL ( IA: NUMBER OF BEDROOMS: 4 _11 GALLONS PER DAY (CPD): 600 PERCOLATION RATE/S: <1 MIN/IN PROPOSED APPLICATION RATE: e4.0 GPD MINIMUM DRAINFIELD SO.FT.: 125 •ADVANCED TREATMENT STILM DRAINFIFI D DESIGN: MAXIMUM DEPTH: 9 FEET WIDTH: 5 FEET LENGTH: 40 FEET M.O.A. APPROVED SAND FILER: 2 FEET EFFECTIVE: 0.5 FEET REDUCTION FACTOR: N/A ACTUAL SO.FT.: 200 CEG. Ltd. HAS A 7 PACE SPECIFICArJON LETTER THAT PERTAINS TO THIS DESIGN. TO ODTAIN A COPY OF THE LETTER CONTACT GEC. BY PROCEEDING FORWARD WITH THIS INSTALLATION. THE ENGINEER. WELL DRILLER. CONTRACTOR AND PROPERTY OWNER AGREE THAT THEY 1 HAVE READ THESE SPECIFICATIONS AND AGREE TO ACCEPT THE TERMS AND CONDITIONS OUTLINED PROPOSED DRAINFI ALTERNATE SITE PROPOSED 1500 S.T.E.P. TANK EXISTING SHED NOTE: THE CONTRACTOR SHALL HAVE THE NORTH LOT LINE AND WEST LOT LINE FLAGGED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION. IBERNARD 5/0; TRACT F-11 O\ APPROXIMATE LOCATION OF EXISTING UNDOCUMENTED CRIB TO BE COMPLETELY A@4NDONED INSTALL FOUNDATION CLEANOUT APPROXIMATE LOCATION OFEXISTING WERUNE. TO BE TM ABANDONED COMPLETELY et GARNESS ENGINEERING GROUP, Ltd. •- - - • CONSULTANTS d GENERAL CONTRACTORS - 3701 1. TJ0011 71C1W0. SUIT 101 • ANC CR.OT. * 00107 •'ICK (007)337-4170 • ,n 007)33e -33M • *U9R: *".001"0"0.0.011.110." PREPARED FOR: PHONE NUMBER: PACE NUMBER: BERNARD STEWART 907-694-3305 2 OF 3 LEGAL DESCRIPTION: BERNARD S/D; BLOCK 3, LOT I -1A TYPE OF WORK: DESIGN OF NEW SEPTIC SYSTEM (Rev. 01105) IDRAWN BY: A.J.G. DATE: 11/13/2008 PROPOSED SEPTIC sTS1tM CPQ BERNARD S/D; TRACT F-1 TRAILER BERNARD 5/0; TRACT E-1 CP Q, - • / / \9RT / Nod mil' ��(4NT / / \\N/ / ,R \0 / \ 1/ A 11 EXISTING \ HOUSE 1 \1 / 111 1100' PROPOSED /1 / / 1 11 // / ARS 6 gto • BERNARD 5/1); BLOCK 3. 1-1B ( SEPTIC ARE!) PROPOSED) \ \ • • / \ \\ ( \\ \ 100' WELL RADIUS i\ \ (PROPOSED) BERNARD S/D; BLOCK 3, LOT 3A BERNARD 5/1); BLOCK 3, LOT 9 C,� I BERNARD BLOCK 3, LOT/10 1 \� GARNESS ENGINEERING GROUP, Ltd. • • • • - • - CONSULTANTS d GENERAL CONTRACTORS..n 71 t VDDR 0010. 411111T 101 • M0106MX. Mf 09507 • NR41i (1107)331-4117 • In (.07)336-314 6fWt eanmemeesweving..ewe PREPARED FOR:PHONE NUMBER: PAGE NUMBER: BERNARD STEWART 907-694-3305 1 OF 3 LEGAL. DESCRIPTION: BERNARD S/D; BLOCK 3, LOT 11A TYPE OF WORK: SITE PLAN DESIGN (Rev. 01/05) DRAWN BY: A.J.G. S E: 1- 100 o P... °pc •4•T/ifi,77* DATE: 11/13/2008 0' A. Carness E— ••1.1.5 ep .(27 it co 10/essiongo 'CIC=1SSo GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS 01 C. 11COl1 ROAD. $OIIC 101 • M1CIa G4 M. 09507 • LEGAL DESCRIPTION: PERFORMED FOR: 20 SOILS LOGGED BY: COMMENTS' -6179 • 14.4: 7 .-}]N • KBLTL jSOIL LOG - PERCOLATION TEST) BERNARD S/D; BLOCK 3, LOT j 1A BERNARD STEWART ORGANICS GP—CM TEST HOLE #1 SOIL CLASSIFICATIONS GW GP GM GC SW SP SM SC DATE: 10/14/2006 ORG ML CL OL MH CH OH DEPTH TO GROUNDWATER DATE DRY 10/14/08 DRY 10/17/08 0 e 1 A. WI V ss.. E-7953 .5p efessientg O�0p0o DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 10/17/08 OOEO PS PS 0ER PeSORgC.,O PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 4.0 FT. AND 5.0 FT. A FOUR HOUR PRESOAK WAS PERFORMED: 0 YES • NO JODY MAUS PERCOLATION TEST PERFORMED BY: KYLE MAUS PERFORMED BY CEG. Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: DATE: 1/6/2009 A ti 2 1 1 1 C s. 0 �i C y N rl P 8 DRAWN BY: K.D.M. LEGAL DESCRIPTION: BERNARD SUBDIVISION. BLOCK 3. LOT I -1A TYPE OF WORK: DESIGN OF QUANICS AEROCELL SYSTEM REPAREU FOR: BERNARD STEWART GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTFACTOFS. ,n. C IMO b* en .61. SOn - NK/ MO[: RN 07-417* (W 1Y AM . til w•I•••••••••.Mp••• PHONE NUMBER: 694-3305 PACE: 3 OF 3 min. 8. 2009 3:144 Garness Engineering Group, Ltd. T-0TN0.5232,008P• tie ADVANCED WASTEWATER TREATMENT SYSTEM MAI\TENANCF AND REPAIR ACREEMENT MEMORANDUM OF UNDERSTANDD G BETWEEN MUNICIPALITY OF ANCHORAGE AND I7frnarla 5}ctna.-f- THIS MEMORANDUM OF UNDERSTANDING made and entered into as of this l6}1'Dayof Ore yen loer of20 by and between !SUrnauc,/ 5i-ewar 4 - herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY." In consideration of the mutual covenants contained herein, the parties to this Memorandum of Understanding agree as follows: 1. ADVANCED WASTEWATER TREATMENT SYSTEMS. Municipality grants permission to Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as /na'tarcn� e $ Act(leII located at R r rem rd 5 4 e Loa r 7— 1 L J—Ili Anchorage, Alaska. 2. Definitions. A. Alteration. Any change to the design or function of an A W WTS that Includes the installation or removal of any parts. components or pieces not included In the original construction permit and design. Prior to performing any alterations to an AWWTS the owner must obtain a Wastewater Disposal System Construction Permit from the Municipality pursuant to Anchorage Municipal Code (hereinafter, "AMC") 15.65. B. Certificate of On -Site Systems Approval. An approval by the Municipality of existing wafer and wastewater disposal systems given at the time of property sale and title transfer in accordance with AMC 15.65. JANJan• 8. 2009 3:14PM Garness Engineering Group, Ltd. T-00.5232/0oeP• 341 These approvals certify that the systems are adequate for the homes that they support and meet the codes that were in place at the time of system construction. C. Damage. Any man-made or natural change in a system that would inhibit the system from performing as designed. D. Maintenance and Repair. The scheduled and as needed replacement of existing pans, components and pieces of an AWWTS that were included in the original design which would allow the AWWTS to continue to perfottn as designed, E.*. Permit (Construction) An On -Sits Wastewater Disposal System Construction Permit as defined by AMC 15.65. F. Permit (Operating) An Advanced Wastewater Treatment System Operating Permit An annual permit, issued by the Municipality, that allows the Owner to operate an AWWTS. upon meeting all the requiremcnu of this ao cement, the conditions of Operating Permit, the requirements oftbc On•Site Wastewater System Construction Permit and all relevant provisions of AMC 15.65 3. Fee. Owner shall pay to Municipality an annual fee of O ($ 0 .00) payable on or before the issuance of the operating permit and annually thereafter. The annual fee is due on or before the anniversary date of the approval by the Municipality of installed system. 4. Term. The term of this Memorandum of Understanding shall be for dee life of the AWWES. ANian. 8. 2009 3:I4PM Garness Engineering Group, Ltd. T-OIll0.5232,0es P • 44e The term begins on the date of approval by the Municipality of the installed system and shall continue while the AWWTS system is in use or operational or until the property is sold or title is transferred by owner and a new certificate of On -Sit: approval Is issued to the new owner or transferee of the property. 5. Atterrationc, Installation and Removal of Additional F4uipment. Owner agrees not to make any alterations, removal of pans or additions to the AWWTS without a Construction Permit from the Municipality. 6. Maintenance and Rerrairs. A. Throughout the term of this Memorandum of Understanding. the Owner shall maintain AWWTS in good repair. In addition, it shall be the responsibility of'the Owner during the term of this Memorandum of Understanding, and any extensions or renewals thereof, at the owner's sole expense, to pay for any and all: (J) repair(s), (2) maintenance, (3) adjustment(s). (4) replacement costs, and (5) inspection costs. Further, Owner agrees to comply will all applicable ordinance, laws, regulations. rules and orders for the AWWTS. B. Owner agrees to provide the Municipality a written schedule of routine maintenance and repairs which have been performed on the system pursuant to the terms and conditions contained in the Owner's AWWTS Operating Permit This schedule shall he submitted to the Municipality annually upon the renewal of the permit. The schedule of maintenance and repair contained in the Owners AWWTS Operating Permit is: l tw.ice. A year C. Owner acknowledges that the fine schedule for failing to maintain and repair an AWWTS are codified in AMC 14.60. LtNJan. 8. 2009 3:14PM Garness Engineering Group, Ltd. T -o0 0.5232006 P. 518 D. Owmer agrees that only maintenance, repair personnel certified by the Municipality will inspect and Hake any necessary maintenance, repairs or permitted alterations to the system. E. Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS upon 24 hours written notice. F. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. Ct. Owner agrees that the relevant provisions of the standard specification guidebook for AWWTS is the governing professional guidelines for the construction, maintenance end repair ofthe Owner's AWWTS. 7. Nonwaiver. The failure ofeitherparty at any time to enforce a provision of this Memorandum of Understanding shall in no way constitute a waiver of the provisions, nor in any way effect the validity of the Memorandum of understanding or any part hereof, or the right of such party thcrestter to enforce each and every provision hereof. 8. Amendment. A. This Memorandum of Understanding shall only be amended, modified or changed by a writing, executed by authorized representatives of the parties, with the same formality of this Memorandum of Understanding was executed and such waiting shall be attached to this Memorandum of Understanding as an amendment. B. For the purposes of any amendment modification or change to the terms and conditions of this contract, the only authorized representatives of the parti:s aro: » Jan. 8. 2009 3:14PM 1� Garness Engineering Green. Ltd. Uec. Ib. luut o:uorn 04111944 tl.0 ...... ..._ _. Owner. C. tri ei5 S tA.)0_r 4— I-ol1Jo.5232'006 P. 6ie Anchorage: Purcha.ting Officer C. Any attempt to amend, modify, or change this contract by either an unauthorized representative or unauthorized means shall be void. 9. Jurisdiction: Choice of Law. Any civil action arising from this Memorandum of Understanding shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Memorandum of Understanding. ID. Severability. Any provisions of this Memorandum of Understanding decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Memorandutn of Understanding. OWI ER: MUNICIPALITY: Date: I," J` e T STATE OF ALASKA THIRD JUDICIAL DISTRICT By: Title: Date: ) ss. The foregoing instrument was acknowledged before 206S,by Ftornard D. SfeLUQrf`- m 4 „_, 001 &4e NOTARY PUBLIC FOR ALASKA My Commission expires' C , - a4 -04 Parcel I.D. 060-321-15 Certificate of On -Site Systems Approval Expiration Date: 7" 1- 2 0 2- 0 1. GENERAL INFORMATION Complete legal description Bernard B 3 L I-1 A Location (site address) 8182 Stewart Mountain Drive Eagle River 99577 Current property owner(s) Henry Vivlamore Day: phone Mailing address 8182 Stewart Mountain Dr Eagle River 99577 Real estate agent Day phone 2. TYPE OF DWELLING: Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well 0 Private Septic 0 Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer: ❑ Waiver request for: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. Distance: COVED -19 25% DISCOUNT APPLIED 5. STATEMENT'OF INSPECTION BY ENGINEER As cerlified.by my seal affixed hereto and as of the validation date.shown below, I verify that my investigation, based on procedures outlined in''. the `Certificate of On -Site Systems Approval Guidelines for this . application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number'of bedrooms and type of structure indicated herein. 1 further verify that based on.the information obtained from the Municipality:of Anchorage..files`and from'my'investigation and inspection, the on-site waier supply andfor.wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations'in,effect at the time of installation. In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features.. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Phone (907) 745-8200 Address P.O. Box 1807 Palmer, AK 99645 Engineer's Printed Name Steven R Pannone Date 8/15/2018 OF A[- i C DSD SIGNATURE TH • • • .1' ��,• / System #1 Approved for bedrooms ... Steve '` R(S n . onnone •` � stem #2 Approved for bedrooms CE -8149S ���cys•. •�,®, ��� Disapproved �i) St Conditional approval for bedrooms, with the following stipulations: 3 . WATER AND WASTE c . Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph S by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Septic System Advisory Well Flow Advisory COSA blue sheet—E _ Nitrate Advisory Arsenic Advisory Other If more than 1 septic system is on the lot: COSA Checklist # 1 of Structure served by this system 1 Certificate of On -Site Systems Approval Checklist Legal Description: Bernard Block 3 Lot I -1A Parcel ID: 060-321-15 A. WELL DATA Well type Private If A, 8, or C provide PWSID 4 Well Log (YIN) Y Date completed 2/10/09 Sanitary seal (YIN) Y Wires properly protected (YIN) Y Total depth 240 ft. Cased to 64 ft. Casing height (above ground) 24 in. FROM WELL LOG Date of test 2/10/09 Static water level 19 Well production 30 AT INSPECTION 7/31/2018 21.9 g.p.m. 4.17 WATER SAMPLE RESULTS: / �' Coliform EG I colonies/100 mL Nitrate mgI_ s dzO Arsenic ND uo/L Date of sample 7 8 Collected by: PES B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Tank size 1500 gal Number of Compartments 2 Foundation cleanout (YIN) Y Depression over tank (YIN) N Date of pumping _' Pumoer JR'S SEPTIC C. ABSORPTION FIELD DATA Date installed 5/11/2011 Cleanouts (YIN) Y High water alarm (YIN) N Date installed °/12/2011 Soil rating (g.p.dJft2 orft2lbdrm) 1'0 9Pd/it2 System type dual fr@nCil Length 60/60 ft Width 5.0/5.0 , ft. Gravel belft ow pi Total depth 3'9/5'8 ft. Eff. absorption area 600 ftZ Monitoring tube Y Depression oD rg(d �� Date of adequacy test 7/31/2018 ResultsPass/Fail PASS** ,4. ( ) For bedrooms Fluid depth in absorption field before test 0/0/014 in Water added 600 gal New depth 010/0/6 in Elapsed Time: 1440 min. Final fluid depth 0/0/014 in. Absorption rate >= 600T ------ g. p. d. Any rejuvenation treatment (past 12 mo.) (YIN & type) N if yes, give date D. LIFT STA TION Date installed Size in gallons _ "Pump on" level at in. "Pump or' level at Datum Cycles tested E. SEPARATION DISTANCES VVELL ONI LOT TO: Septic tank/lii station on lot 00+ , Absorption field on lot i 00+ Public sewer main 75+ r Sewer /septic service fine 0+ Animal containment areas 50 -- SEPT] C/IHOLDING 0+ SEPTIC/HOLDING TANK ON LOT TO: 10+ 5' Building foundation Water main 10-1 V:fells on adjacent lots 1 Manhole/Access (YIN) in. High water alarm level at in. Meets alarm & circuit requirements? On adjacent lots 100+ On adjacent lots 100+ Public sewer manho!e/cleanout 100+ Holdino tank 100+ ivlanure/animal excrete storage areas _ ' Properly line Water service line 10+ ABSORPTION FIELD ONI LOT TO: Property line 0Y Buildinc foundation 10-~- }•'Vater Service line 1 Surface water 100+ Curtain drain 00- Wells on adjacent lots 100+ Absorption field 5+ Surface stater 100+ VVater main '10 - Driveway, parkingivehiclestgrage I+ F. COMMENTS �I � ��1��� .' �1 f I 1 oAu , &Mv�o '' *The north field flooded with the introduction of 130 gallons the south trench remained dry the remaining 470 gallons aeras introduced directly into the south trench which remained dry. _ M 1 ��G'`S" a t�u��, .l ; t��r >l�tTj S Owl), . G. ,ENGINEER'S CERTIFICATION Celifi f that ! have determined through field inspeCu0ns and review of Municipal records that' the above systems are in conformance v1ith MOA COSA guidelines in effect on this date. Engineer's Printed Name Steven Pannone Date COSA canary shee�_2-5-15.doc 9/12/2018 r Steven R. Pannone �¢c.. CE -8149E > 3 10 77 • • W 3- •FF `##`yy �-{ Municipality of Anchorage oaF`f'xa r.., i �tx {z .11S 8 3 • On-Site Water and Wastewater Program +lo�11'4 (907) 343-7904 12111 E,. C h� Certificate of On-Site Systems Approval !� °� 6 8 9 Parcel I.D. 060-321-15 Expiration Date: ( ` '3 ( 1. GENERAL INFORMATION Complete legal description Bernard Block 3 Lot I-1 A Location (site address) 8182 Stewart Mountain Drive Current Property owner(s) Henry & Kunsulu Vivlamore Day phone Mailing address 8182 Stewart Mountain Drive Eagle River, AK 99577 Real Estate Agent Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: h / \ f Received b .�. o 1 �� I Date: 1111 t 1 Q COSA to be released to the engineer,unless otherwise requester 2y the engineer. COSA Fee $ 5.A4 Waiver Fee $ Date of Payment EV/C/a Date of Payment Receipt Number a 3 90 04 Receipt Number COSA# QVIYilS Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in' the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,and regulations'in effect at the time of installation. In conducting an adequacy test,I attempt to provide a thorough,conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations.The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition,ground water levels that may fluctuate during the year,and the water usage of the family being served by the system.These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system,nor do they guarantee that there are no hidden defects or encroachments.Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Phone (907) 745-8200 Address P.O. Box 1807 Palmer, AK 99645 Engineer's Printed Name Steven R Pannone Date 8/15/2018 OF Aqkk 6. DSD SIGNATURE 49 •p4 ?C System#1 Approved for bedrooms •':Steven R.• ne System#2 Approved for bedrooms rY9•• CE-8149 � Disapproved ��OFESSI�� Conditional approval for bedrooms, with the following stipulations: ON-SITP 1)'s. WATER AND WASTEWAI ER PROGRAM 1 / Original Certificate Date: 9 - ( I The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet r If more than 1 septic system is on the lot: COSA Checklist# 1 of 1 Structure served by this system 1 Certificate of On-Site Systems Approval Checklist Legal Description: Bernard Block 3 Lot I-1A Parcel ID:060-321-15 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (YIN) Y Date completed 2/1 0/09 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Total depth 240 ft. Cased to 64 ft. Casing height(above ground) 24 in. FROM WELL LOG AT INSPECTION Date of test 2/10/09 7/31/2018 Static water level 19 ft. 21 9 ft. Well production 30 g.p.m. 4.17 g.p.m. WATER SAMPLE RESULTS: Coliform NEG colonies/100 mL Nitrate 1.82 mg/L Arsenic ND ug/L Date of sample: 7/31/2018 Collected by: PES B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 5/11/2011 Tank size 1500 gal. Number of Compartments 2 Cleanouts(Y/N) Y Foundation cleanout(Y/N) Y Depression over tank(Y/N) N High water alarm (Y/N) N Date of pumping t -a —1 le Pumper JR'S SEPTIC C. ABSORPTION FIELD DATA Date installed 5/12/2011 Soil rating2 2 1.0 gpolft2 dual trench (g.p.d./ft or ft/bdrm) System type Length 60/60 ft. Width 5.0/5.0 ft. Gravel below pi 0 ft. Total depth 3.9/5.8 ft. Eff. absorption area 600 ft2 Monitoring tube Y Depress] n over NM Date of adequacy test 7/31/2018 Results(Pass/Fail) PASS** For 4 bedrooms Fluid depth in absorption field before test 0/0/0/4 in. Water added 600 gal. New depth 010/0/6 in. Elapsed Time: 1440 min. Final fluid depth 0/0/0/4 in. Absorption rate >= 600+ P g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N &type) N If yes, give date D. LIFT STATION Date installed • Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off'level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100+ On adjacent lots 100+ Absorption field on lot 100+ On adjacent lots 100+ Public sewer main 75+ Public sewer manhole/cleanout 100+ Sewer/septic service line 25+ Holding tank 100+ Animal containment areas 50+ Manure/animal excrete storage areas 100+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 10+ Property line 5'+ Absorption field 5+ Water main 10+ Water service line 10+ Surface water 100+ Wells on adjacent lots 100+ ABSORPTION FIELD ON LOT TO: Property line 0* Building foundation 10+ Water main 10+ Water Service line•10+ Surface water 100+ Driveway,parking/vehicle storage 1+ Curtain drain 50+ Wells on adjacent lots 100+ F. COMMENTS V\acve,{on i4.e ' �Q I I [DAU , S son 4:.Q, . **The north field flooded with the introduction of 130 gallons the south trench remained dry the remaining 470 gallons was introduced directly into the south trench which remained dry. - (NA-TAnaS Ott pk 1�Au ,All ate, MT►s011/4, N.G. .ENGINEER'S CERTIFICATION �. F A4., I certifythat1 �'<P`����AC�s�I� have determined through field inspections and co.. •4. .y f¢ review of Municipal records that the above systems are in ;7*; ,;� I\ .�r conformance with MOA COSA guidelines in effect on this date. •••• •' r(•• Engineer's Printed Name Steven Pannone r •Steven R. Pannone• Date • 9/12/2018 • ��}��y. CE-8149 �� COSA canary sheel_2-6-15.doc Municipality of Anchorage On -Site Water & Wastewater Program (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 060-321-15 1. GENERAL INFORMATION Complete legal description Location (site address) Current Property owner(s) Mailing address Real Estate Agent Expiration Date: BERNARD STEWART S/D; BLOCK 3, LOT 1-1A 3-3-13 8182 STEWART MOUNTAIN DRIVE, EAGLE RIVER, AK, 99577 NATHAN GUBSER Day phone 317-1975 8182 STEWART MOUNTAIN DRIVE, EAGLE RIVER, AK, 99577 CINDY LINDBLOM W/ GREATLAND REALTY 2. TYPE OF DWELLING: • Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System • 4 Day phone 694-9125 TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding tank Community On-site Public Sewer • Received by: ii/R144.n.G�r�S� 7/3/13 COSA to be released to the engineer, unless otherwise requested by the engineer. Date: COSA Fee $ (V° S Date of Payment Receipt Number COSA* 031(16 6- 131z g y Waiver Fee $ c2 Q'O'M Date of Payment Receipt Number Waiver # 05A I r 6 9 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, i verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate fer the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there am no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 6. DSD SIGNATURE System #1 Approved for bedrooms. By: System #2 Approved for bedrooms. Disapproved. Date ``s�'�4`0` OF (tiffs I ON-SITE Conditional approval for bedrooms, with the following stipulations: - WATER AND WASTEWATER PROGRAM i�ln_ ShO Original Certificate Date: 7 )3 The Mtinicip ity or An age Develop,emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist Septic System Advisory Well Flow Advisory (Rev. 11/05) Nitrate Advisory Arsenic Advisory Other 1 ''Ok' • • Signature GARNESS ENGINEERING GROUP, Ltd. July 2, 2013 CONSULTANTS & GENERAL CONTRACTORS Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Rd. P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 Reference: Bernard Stewart B3, L1 -1A, Permit # OSP111045 To Whom It May Concern, Per your departments requirements referenced on the Gayness Engineering Group, Ltd. (GEG) waiver request letter, addressed to your department, and dated 6/26/13, the homeowner worked with a contractor to expose the pitless adapter on the existing well to inspect the presence/absence of a bentonite seal. During the excavation around the well, the owner and contractor experienced dangerous wet sloughing soils that began to slough towards the house. When the sloughing had come within approximately 5' of the house foundation, the owner and contractor made a decision to backfill the excavation to protect the house foundation. It is reasonable to believe that without major excavation which may include excessive trenching, sheet piling, and site drainage work, the pitless cannot be inspected using conventional methods (see attachment from ARM Services). It was then our recommendation that the pitless be inspected from inside the well, to inspect for any leaks. Being that the pitless is currently sitting in groundwater, an inspection of the pitless (if found to be dry) would prove that the seal is free of leaks. After GEG discussed the project with Jay Crewdson, the owner hired Cole Sullivan who pumped down the static water level, and inspected the pitless via camera. The inspection reflected that the pitless is in fact not leaking (see attachment from Sullivan Water Wells). The house has been occupied for several months, utilizing the existing sewer line. It should be noted that GEG pulled water samples on 6/12/13, and the Coliform sample results reflected 0 colonies/100 ml. We request that w.,'ver requested on 6/26/13 be granted at this time. Pres' E., M.S. 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: gamessengineering.com ARM Services, LLC June 29, 2013 Garness Engineering Group 3701 E. Tudor Road Anchorage AK, 99507 Reference: 8182 Stewart Mountain Drive — Well Pitless To Whom It May Concern, On 6.29.13, ARM Services, LLC (ARM) attempted to expose the pitless adapter on the existing well located at the referenced property, to inspect the bentonite seal, or install new bentonite if required. During the attempt, the closest edge of our excavation (9.5' deep) did not extend past the South side of the well casing (towards the house), when wet sloughing soils were encountered. Over the course of the next 45 minutes, soils began to slough off moving rapidly towards the house foundation, intensifying as time went on. When ARM and the home owner became uncomfortable with the sloughing soils near the foundation, a decision was made to quickly backfill the excavation to stop further sloughing. At this time it is our understanding that the pitless on the well cannot be safely exposed or inspected, based upon the location of the well, without the completion of extensive drainage work on the property ($15,000-$20,000 rough estimate), or the installation of sheet piling to protect the house foundation (price unknown). It is our recommendation that a Municipal certified pump and well company (such as Sullivan Water Wells) is hired to inspect the pitless from the inside of the well with a camera. Since we know that the pitless is currently sitting in groundwater (at a depth of approximately 11'+), an inspection of the pitless from the inside of the well should negate the need for inspection via excavation. We believe that an inspection of pitless from the inside will prove that the connection is water tight, and free of leaks. Please feel free to contact me with any questions. Respectfully, Rob Campbell Managing member ARM Services, LLC (907) 317-9433 24738 Chugiak Drive *Chugiak, AK 99567 Ph: (907) 317-9433 office/fax: (907) 688-9433 Email: ARMServicesAK@outlook.com 1� \ \ se pUC S Ngo° \��RT Mo v NT,9iv ?47 fS Itit 'F 2 W CO w Lw O)''Z a0 Z } Cr) O W U J LJJ W CO ih 8 \ '5- o • ors rsego. Po • I 6 Gravel driveway Rock wall (typ) SCO 2 Story Frame Shop 10 • N 2 StoryFS50 34.0 Mouse me LOT 1-1A 24. 0 9 hto / L__ LF w-4 1 112.5 1 \2 N d N ill N I Nco .Z I 12.5 \ \ pct' \ ° \ \ 14i "ILS' \\ • LOT I-1 B 83541 • • • \ • \ \ SCALE 1"= 40' EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED PLAT ARE;NOT SHOWN HEREON. Fb 12-7, pg 65 N89°56'30"E 310.41 20' ALLEY .`-.....ao••\00 <€.9F•.C4s1 1 * /(t,. ...c`�L // •• Fred Walatka 0;� rr (3 •. No. 3255-S _, OFESSIgNg. \ • REVISED 6-05-13 ADDED CLEANOUT AS -BUILT NO CORNERS SET THIS DATE I hereby certify that I have performed a Mortgagee's inspection of the following described property: LOT I -1A, BLOCK 3, BERNARD SUBDIVISION Anchorage Recording Precinct, Alaska, and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Anchorage, Alaska this 1st day of November 2012 FRED WALATKA & ASSOCIATES Engineers and Surveyors BE (907-248-1666) Municipality of Anchorage On -Site Water & Wastewater Program (907) 343-7904 1 ir: as JP— e ' w dm CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 060-321-15 1. GENERAL INFORMATION Complete legal description Location (site address) Current Property owner(s) Mailing address Real Estate Agent Expiration Date: BERNARD S. RT S/D; BLOCK 3, LOT 1-1A 8182 STEWART MOUNTAIN DRIVE, EAGLE RIVER, AK, 99577 NATHAN GUBSER Day phone 317-1975 8182 STEWART MOUNTAIN DRIVE, EAGLE RIVER, AK, 99577 CINDY LINDBLOM W/ GREATLAND REALTY 2. TYPE OF DWELLING: ▪ Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System • 4 Day phone 694-9125 TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding tank Community On-site Public Sewer 1 Y/ Received b : : _�� COSA to be released to the engineer, unless otherwise requested by the engineer. Date: COSA Fee $ S CIO Date of Payment Receipt Number COSA # 7-/qo6 Waiver Fee $ Date of Payment Receipt Number Waiver # 079 64 Q s P/3/109 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK, 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date (c(t6`a Engineer's Comments: 1n conducting this evaluation, GEG, LID. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSO Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local sails condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for Me sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 6. DSD SIGNATURE System #1 Approved for System #2 Approved for Disapproved. V Conditional approval for bedrooms. bedrooms. 0_006000p04 751 *VDO D ey & arness CE 795 ap Qa Professiocoo 04�000�� bedrooms, with the following stipulations: r r P i ' ( 1 /1 / E_ Ccirdu/ ttmt 9- toe re-(�astG( r/,iT,( CJS cc. cjrve-t-/�=�t At r Dn L/ i fl4 / etppro vQ 1 wt 17 12 Lot 1 S'5c0S,a /31/69 vcicc.rfrek 1S airf',3VC/ 1 C.9 . S! (er Vrvct-i UCS DVI; ;hn ( rvi. teC:1ieK fti`.�'vel:- Original Certificate Date: 6- 22- / 7 By: (t The Municiprage Develop,emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist Septic System Advisory Well Flow Advisory (Rev. 11/05) Nitrate Advisory Arsenic Advisory Other If more than 1 septic system is on the lot: COSA Checklist # of Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: BERNARD GTE -WART- S/D; BLOCK 3, LOT 1-1A A. WELL DATA Well type PRIVATE Parcel ID: 060-321-15 *BEDROCK ® 53' If A, B, or C provide PWSID# N/A Well Log (Y/N) YES Date completed 2/10/2009 Sanitary seal (YIN) YES Total depth 232 if. Cased to *64 ft. Wires properly protected (Y/N) YES Casing height (above ground) 18+ in. FROM WELL LOG AT INSPECTION Date of test 2/10/2009 6/12/2013 Static water level 19 ft. 4 ft. Well production 30 g.p.m. 8.08 g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 ml. Nitrate 2.19 mg./L. Collected by: GEG, Ltd. Arsenic: AJ 0 ug./L. Date of sample: 6/12/2013 B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 5/11-12/2011 Tank size 1500 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) N/A Date of pumping NEW Pumper - C. ABSORPTION FIELD DATA *BELOW EXISTING GRADE Date installed 5/11-12/11 Soil rating.p.d./ r ft2/bdrm) 1.0 System type DUAL TRENCH Length 120+ TOTAL ft. Width 5/5 ft. Gravel below pipe 0.5/0.5 ft. *4.1+/ Total depth *4.1 + ft. Eft. absorption area 600+ ft2 Monitoring tube YES Depression over field NO Date of adequacy test **NEW Results (Pass/Fail) PASS For - bedrooms Fluid depth in absorption field before test - in. Water added =gal. New depth - in Elapsed Time: - min. Final fluid depth - in Absorption rate >= - g p d Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date - **SEPTIC SYSTEM WAS INSTALLED IN MAY 2011, BUT HOUSE HAS BEEN OCCUPIED FOR LESS THAN 2 YEARS. D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at a =r alarm level at in. Cycles tested Meets alarm & circuit requirements° E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent Tots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main N/A Public sewer manhole/cleanout N/A Sewer /septic service line ** Holding tank N/A Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line *0'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 1' Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS *WAIVER #OSP111046 **SEE ATTACHED WAIVER REQUEST G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date 6126/!.? (Rev. 11/05) ESCROW HOLDBACK AGREEMENT To: Integrity Title Agency Agreement between:- Henry T. Vlvlamore and Kunsulu Vivlamore, husband and wife Buyers) and Nathan D. Gubser and Karissa 1. Gubser, husband and wife Seiler(s) Amountwithhefd: $3,000.00 The undersigned parties authorized Integrity Title Agency to escrow funds in the amount of $3,000.00 from the Seller. For the purpose of: Well & Septic It is the sole responsibility of the undersigned parties to provide Invoices to Integrity Title Agency for payment. Upon receipt, Integrity Title Agency shall pay invoices for the above-mentioned work. In the event parties are requesting to be reimbursed for invoices they paid out of pocket, Integrity Title Agency will require evidence of paid Invoices before any reimbursement Is paid. if work Is not completed by September 01, 2013, Integrity Title Agency shall disburse the balance of the escrow I hold to Henry & Kunsulu Vivlamore without further consideration. This escrow -hold agreement does not contain a I provision to extend the completion date. • The undersigned parties hereby jointly and severally indemnify and hold Integrity Title Agency harmless from and against all costs, damages, judgments, attorneys' fees, expenses or obligations every kind and descriptions which, in good faith, it may incur or suffer in connection with this escrow, Dated: June 27, 2013 Buyer(s): Henry T. Vivlamore Kunsulu Vlvlamore Seller(s): Nathan D. Gubser Ka ' sa L. Gubs READ AND APPROVED BY: Integrity Title Agency Brenda State 'RreskfeFlt Ma i MSL File No.: 45599-1423 AKC Escrow Holdback Agreement Page t of l i ARM Services, LLC 24738 Chugiak Drive Chugiak AK, 99567 Bill To: Nathan Gubser PO BOX 671341 Chugiak, AK 99567 Description Est. Hours/Qty. Proposal Proposal Date: 6/26/2013 Proposal #: 5 Project: Rate Total This proposal includes the excavation and exposing of the pitless adapter on the existing well casing. The pitless shall be exposed, and encased in bentonite. Per the well drillers recommendation, only 1" of soil shall be removed from underneath the pitless (to be replaced with bentonite) to minimize possible settlement. The owner is responsible for supplying locates for any un -marked underground power lines or utilities. The excavation will be back filled with the existing material removed from the excavation. 1,295.00 1,295.00 Please read and sign the "Residential Addendum A" provided as it applies to this contract 60% down required, remaining balance due upon completion of work. 8182 Stewart Mountain Drive Total $1,295.00 By signing below, the client agrees to the proposed work terms, and price. The client has also read and signed the 'Residential Addendum A" and agrees to the terms. The client acknowledges that ARM Services, LLC has the right to lean this property. SIGNATURE AND DATE ARM Services, LLC Residential Addendum A Unless stated otherwise in writing, this bid does not include the following: • Engineering costs for inspections for the installation or preparation of as -built drawings. • Site clean-up • Importing of additional soils or materials beyond what is required to install the septic system. • Landscaping, topsoil and seeding • Exporting of trees, brush and shrubs removed during this project. These items shall be stockpiled onsite. • Exporting of excess soils • Replacing of items such as sidewalks, fences, decks, sheds and other similar items removed as part of this work • Replacement or repair of unmarked private residential utilities (such as buried power/gas lines between buildings, not located by the locate services) • Prep work required prior to topsoil and seeding and or paving Typically, there is excess soil left over that was displaced by items such as the septic tank and drainrock. This soil will be spread out onsite as required to achieve the proper burial depth of all components, and to achieve positive drainage (rain, melting snow) away from the septic system. This will likely change the original landscape of the yard. The staging location for all imported soils, sewer rock or other materials required for this job will be chosen at the discretion of the contractor unless specified otherwise by the owner in writing. Every attempt shall be made to choose a location that will minimize damage to existing landscaping or driveways and parking surfaces; however in some cases it may be necessary to stage the imported materials (i.e. sewer rock, septic sand or other materials) on paved/unpaved driveway surfaces or landscaped areas. This contract does not include any site cleanup or restoration of the areas damaged by material staging. Large dump trucks and other heavy equipment can have a detrimental effect on paved surfaces. It is possible through the process of moving materials and equipment on site, that graveled or asphalt surfaces may be damaged. ARM Services, LLC assumes no liability for any damages to gravel or asphalt surfaces during construction., In short, there will be no repairs made to any paved or aggregate driving surfaces as part of this contract. 24738 Chugiak Drive *Chugiak, AK 99567 Ph: (907) 317-9433 office/fax: (907) 688-9433 Email: ARMServicesAK@outlook.com ARM Services, LLC The installation will be conducted per the engineer's design. Each design is based upon limited data required per the municipal code. The majority of the time, septic systems are installed without any issues or design changes; however, it's important to note that unforeseen issues can arise, dictating the need for a design change or a change order. Such unforeseen issues include but are not limited to: • Negative or insufficient grade from the structure to the septic system, which may require excessive excavation to acquire grade, dictating the need for a lift station. • Changes in groundwater or soil conditions that dictate design changes. • Unforeseen subsurface conditions such as large boulders, shallow bedrock or excessive sloughing of soils (which require use of excess quantities of drain rock, or the use of trench boxes to protect workers). • Differing soil types and/or groundwater conditions which dictate changes to the design. By signing and dating this document, the owner or authorized representative is agreeing to the terms and conditions of this contract. Signature: Date: Property address/site description: 24738 Chugiak Drive *Chugiak, AK 99567 Ph: (907) 317-9433 office/fax: (907) 688-9433 Email: ARMServicesAK@outlook.com