HomeMy WebLinkAboutPARADISE VALLEY BLK 6 LT 4Paradise Volley
Block 6
Lot 4
#020-412-21
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Pump Installation Log
Well Drilling Permit Number: SW141141 Date of Issue: 06.03 -14
Parcel Identification Number: 020 _ 412 _ 21
Legal Description
Paradise Valley
Block
6
Lot
4
Property Owner Name & Address:
Pisonth & Vanida Keyuravong.
13201 Westwind Drive.
Anchorage Alaska 99516-3406
Pump Installation Date: 10 - 25 -23
Pump Intake Depth Below Top of Well Casing: 280
feet
PENTAIR 4" submersible pump
Pump Manufacturer's Name:
Pump Model: B7P4JP05221-02 7196097
1 /2
Pump Size: hp
4
Pitless Adapter Burial Depth: feet
Pitless Adapter Manufacturer's Name: MERRILL SSMB200 IMP
Pitless Adapter Installer:
__._--- ___._,___ .____ __
Well Disinfected Upon Completion? ❑ Yes ❑ No
Method of Disinfection: Chlorine slow release tablets
Comments:
Encounter shallow bed rock. Stick up will be extend to 2 feet above a new established grade.
Pump Installer Name: Pisonth Keyuravong PE.
Company: Owner
Mailing Address: 13201 Westwind Drive.
City: Anchorage
State: Alaska Zip: 99516.
Attention: The pump installer shall provide a pump installation log to On -site within 30 days of pump installation.
Pisonth and Vanida Keyuravong
13201 Westwind Dr
Anchorage, AK 99516
907-562-1252
pisonthkey&hotmail.com
vanida kna,hotmail.com
January 15, 2019
Ms. Rebecca Carroll
Development Services Department
On -Site Water and Wastewater Section
Municipality of Anchorage
PO Box 196650
Anchorage, AK 99519-6650
RE: Well Permit # OSP141141
Dear Ms. Carroll:
In response to your certified letter dated January 9, 2019, we would like to provide you
with our current well development plan. Our well was drilled by David Harper of Alpine
Drilling The pump, pipes, and electrical system have not yet been installed. We were
advised to not install these items until we were ready to operate because it could cause
problems with our ongoing construction.
We are now traveling and will not return until mid-March 2019. Our house construction
work will restart in the spring of 2019. We will install the pump, water system, submit a
well log, water quality test results, and fulfill any other requirements items as deemed
necessary by MOA when our house construction is completed.
We hope this letter will satisfy your questions. Thank you for your concern and
understanding .
Sincerely,
pl. �k
Pisonth and Vanida Keyuravong
1 is
Permit Number: #SW 141141 Date of Issue: 6-3-14 Parcel Identification Number: 02041221000
Date Started: 6-2-15 Date Completed: 6-3-15 Is well located at approved permit location? x Yes ❑ No
Legal Description: Paradise Valley Block 6 Lot 4
Property Owner Name & Address: Keyuravong Pisonth & Vanida
13201 Westwind Drive
Anchorage, Alaska 99516-3406
Borehole Data: Depth (ft)
Method of Drilling x air rotary ❑ cable tool
Soil Type, Thickness & Water Strata From
To
Casing type: steel
Stick-up 0
2
Wall Thickness..250 inches
Bedrock 2
�87
Diameter: 6 inches Depth: 43 feet
Liner Type:
Diameter: inches Depth: feet
H2O 79
81
Casing stickup above ground: 2 feet
Static water level (from ground level): 71 feet
H2O 260 265
Pumping level: 280 feet after
2 hours pumping 2_5 gpm
Recovery Rate: 2_5 gpm
Method of Testing: air liLt
Well Intake Opening Type:
❑ Open End x Open Hole
❑ Screened Start feet Stopped feet
su
WATER QUALITY TESTING
❑ Perforations Start feet Stopped feet
Grout Type: bentonite Volume: 4
4olifiorm �F. Ci �jj1
Depth: Start 0 feet Stopped 41 feet
Pump: Intake Depth feet
Pump size hp Brand Name
Nitrates ,moo M9&
Arsenic S• h
Well Disinfected Upon Completion? x Yes ❑ No
Method of Disinfection: chlorine tablets
�Z y
Comments:
Well Driller: Alpine Drilling & Enterprises
PO Box 110496
__...___.__.._......._._
Please save for your engineer.
Anchorage AK 99511
This is needed for yopr COSA.
G ,� f 1 r
On -Site Water System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP141141
Tax Code Number: 02041221000
Work Type: Well Initial
Permit Effective Dates: June 03, 2014 to June 03, 2015
Design Engineer:
Subdivision: PARADISE VALLEY
Site Legal Address: PARADISE VALLEY BILK 6 LT 4 G:3538
Owner/Address: KEYURAVONG PISONTH & VANIDA
13201 WESTWIND DR ANCHORAGE AK 995163406
Site Mailing Address: 18000 Norway CIR, Anchorage
This permit is for the construction of:
Lot Size in Sq Ft: 19468
Total Bedrooms: 4
N Disposal Field N Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Issued By: Ll Z41
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. O!Jr, 412 21
Propertyowner(s) icE%'IiRAVnL4j& ( 4PI.5GI�% VANVW Day phone 562-19-52
Mailing address 132QI WI;iU3tfAb i e ti1KQ-y"16_P_
Site address VktAN'T 1 kj, b
Legal description (Sub'd., Block & Lot) WA111.4F� LLDO i:� i , LO -FA
Legal description (Township, Range & Section)
Lot Size IQ 4(&i Sq. Ft.
APPLICATION IS FOR:
(® all that apply)
Absorption Field
❑
Septic Tank
❑
Holding Tank
❑
Privy
❑
Private Well
Upgrade ❑
Water Storage
❑
Number of Bedrooms 4
APPLICATION IS AN:
TYPE OF DWELLING:
Initial 54
Single Family (SF)
(w/wo ADU)
Upgrade ❑
Duplex (D)
El
El
Multiple Dwellings
❑
(SF and/or D)
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
a'LCz L 2R iit
(Signature of prope wner or aWhorized agent)
Permit/Rush Fees: 42-15 Waiver Fees:
Date of Payment: 5 jZ111q Date of Payment:
Receipt Number: #- 1pno&o Receipt Number:
Permit No. 195P IL4I I u1 Waiver No.
Permit App_:- : .
c
o m
A �
M —
r�i o
u
OCL
csq!:E
L
On -Site Water System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP121308
Tax Code Number: 02041221000
Work Type: Well Renewal
Permit Effective Dates: September 28, 2012 to September 28, 2013
Design Engineer:
Subdivision: PARADISE VALLEY
Site Legal Address: PARADISE VALLEY BILK 6 LT 4 G:3538
Owner/Address: KEYURAVONG PISONTH & VANIDA
13201 WESTWIND DR ANCHORAGE AK 995163406
Site Mailing Address: 18000 Norway CIR, Anchorage Lot Size in Sq Ft: 19468
Total Bedrooms: 4
This permit is for the construction of:
N Disposal Field N Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received Bu: V �h&
Issued By:
47�1129'1J'
MUNICIPALITY OF
Community Development Department
Development Services Division C*
On -Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWERNVELL PERMIT APPLICATION
Parcel l.D. 62b--412-
Property owner(s) j `U_L�VoW6 i -OW 1-1-}NP**Dayphone 5az-12S72
Mailing address
Site address 4
'k.
Legal description (Sub'd., Block & Lot) ORADVE \IRL,LEY .gLMY, �: 1.614
Legal description (Township, Range & Section)
Lot Size 19,,49 Sq. Ft.
APPLICATION IS FOR:
(® all that apply)
Absorption Field
❑
Septic Tank
❑
Holding Tank
❑
Privy
❑
Private Well
N
Water Storage
❑
Number of Bedrooms 4
APPLICATION IS AN:
TYPE OF DWELLING:
Initial ❑
Single Family (SF)
(w/wo ADU)
Upgrade ❑
Duplex (D). ❑
Renewal
Multiple Dwellings ❑
(SF and/or D)
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
signature of propeM owner or
Permit/Rush Fees: /Jo
Date o� a l tt la
�ese;pt-r ,ber'_ N 1 R
Permit No.05fjD1308
Permit App_9-1-12.doc
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
MUNICIPALITY OFANCHORAGE
Development Services Department
On -Site Water d Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT
Initial
Date Issued: Jan 20, 2009
Expiration Date: Jan 20, 2010
Permit Number: SW090008 Parcel ID: 020-412-21
Legal Description: PARADISE VALLEY BLOCK 6 LOT 4
Design Engineer: 0014 ANDERSON ENGINEERING Site Address: NHN NORWAY DRIVE
Owner Name: PISONTH & VANIDA KEYURAVONG Lot Size: 0 SO. FT.
Owner Address: 13201 WESTWIND DRIVE Total Bedrooms: 4 Permit Bedrooms: 4
ANCHORAGE, AK 99516 -
This permit is for the construction of:
Q Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
A. Permit includes waiver #W R090006, allowing a V absorption field to south property line separation distance.
Received By
Issued By
Date: I^ DL "65
Date: % �)
Municipality of Anchorage
P.O. lAxc 119;650 • AnchomGc, Alaska VA19-fifi,50 * 47(X) lilmnrc R.uid
Oaicc: CM) 333-K901 • rnx: ((X)7)=.820(X) help://x���anumi.ury;
31att Claman, Development Scr%iccs Dcl)artrncnt
doing Mayor
January 21, 2009
Alike E. Anderson, F.E.
Anderson Engineering
Subject: Waiver Request for Paradise Valley; Block 6; Lot 4
Waiver Request Number: WR090006
Parcel ID: 020412-21
Permit Number: SW090008
Dear Mike E. Anderson, P.E.:
Your waiver request for the item(s) listed below;
• I foot absorption field to south property line separation distance
has been approved.
?N,ENT S
z-
� o
m
O e a
DEPARTMENT
This waiver approval applies to the item(s) listed above only. Any future upgrade to the
on-site wastewater disposal system will require all separation distances be met or another
approval from this department.
If there are any further concerns or questions regarding this waiver, please call our office
at 343-7904.
Yly,
Jay" Crewdson, P.E.
Civil Engineer
On -Site Water & Wastewater Program
Connnfill ity, Security, Prosperity
Municipality of Anchorage
Development Services Department
Building SafLty Division
On -Site WatLv and Wastewater Program
4700 Bragaw Street
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchoragc.ak.us
(907)343-7904
Waiver Review Worksheet
Waiver# WR090006 PID# 020412-21 Permit# SW090008
Date Received: November 17, 2006
Legal Description: Paradise Valley; Block 6; Lot 4
Engineer. Mike E. Anderson, P.E.
Applicant: Plsonth S Varlda Keyuravong
Waiver Requested: 1' absorption field to south property line separation distance.
Criteria: Geology Points:
A. Water Table
B. Soil Sorption
C. Permeability
D. Water Table Gradient
E. Horizontal Separation
Total:
............................... Monson ... awesome ... ones ... ......@.... @soon
Waiver is Granted: X Waiver is not Granted.
List Conditions or Reasons for above:
Adjacent property is vacant. See design for more detail.
Date: 1121109 By: Jay Crewdsonn
Name of Reviewer
............................................ *sea, ...
....................•
Rec#: 045978 Amount: $ 175.00 Date Paid:11 117108
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 FAX
November 11, 2008
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 4, Block 6, Paradise Valley Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 4, Block 6, Paradise Valley Subdivision intends to construct a new
four-bedroom home on the lot. A new shop will also be constructed with plumbing
facilities. We are therefore requesting a permit be issued for the construction of a new
well and septic system to accommodate the home and shop. The attached Site Plan
and backup documentation identify the location and configuration of the proposed
septic system along with the alternate site. No existing wells or septic systems are
closer than 100' from the proposed well or septic system. Drainage arrows are shown
on the site plan showing the grade and direction of flow on the lot. The drainage
pattern will not be changed as a result of this project.
The test holes placed on the lot in the area of the absorption trench and alternate site
indicated gravel with sand and silt (GM/GP). The percolation rate of the soil was
determined to be between 1 and 5 minutes per inch. No groundwater was found during
the placement of the test holes and none was noted during the monitoring period.
Bedrock was found in both test holes at 7' below the surface. An application rate of 1.2
gallons per day per square foot was used in the design of the absorption system. We
are proposing to place a new 1,500 -gallon STEP tank and a total of 100' long in 3
segments by 5' wide by .5' effective depth absorption trenches to treat and dispose of
the effluent generated in the house. The elevation of the distribution line in the
absorption trench will be .5' below the surface and the total depth will be 1'. A minimum
of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trenches and
4' over the STEP tank.
The ground surface on the lot in the area of the absorption trenches slopes to the
southwest at a grade approximating 20%. The new trenches will be constructed
Lot 4, Block 6, Paradise Valley Subdivision
November 11, 2008
Page Two
paralell with the slope contours as much as possible in conformance with Municipal
requirements. The new septic system will be constructed a minimum of 100' from all
wells and any surface water and 10' from the proposed and existing water services in
the area. The house, shop and STEP tank will be lower than the absorption trenches
with the septic effluent pumped to the absorption area through a 1.25" PVC line.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely, e
"fes- ZE
Michael E. Anderson, P.E.
Attachments
s _ s
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
622-7773 677-7766 FAX
November 11, 2008
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
P.O. Box 196650
Anchorage, AK 99519-6650
Subject: Lot 4, Block 6, Paradise Valley Subdivision
Separation Distance Waiver
Absorption Trench to Lot Line
Dear On Site Services Engineer.
Lot 4, Block 6, Paradise Valley Subdivision is plagued by bedrock at shallow depths
which restricts the area available for an absorption trench. Test holes recently placed
at the northeast comer indicate bedrock at sufficient depth to support an absorption
system. This area, however, encroaches into the 10' setback from the property line.
Soils at this location are well to poorly graded gravel with silt which is normally effective
in the absorption and treatment of septic effluent. Placement of the absorption
trenches within 1' of the southern lot line will not adversely affect neighboring lots. The
lot to the south is currently vacant and no area has yet been found which will support an
on site septic system. We hereby recommend a lot line waiver be issued allowing
placement of the absorption system within 1' of the southern lot line.
Sincerely, n
Michael E. Anderson, P.E.
49th
WCNAEL E. ANDERSON
t
t
I
I
t
LOT 13, BLOCK 6 i
KENO HILLS NO. 6
I
1
t
t
i
E
,
1
1
1
1
1 LOT 6, BLOCK 6
KENO HILLS NO. 5
'
,
t
t
1
I LOT 3IBL�K 6
PARADSE VALLEY
\ 4
T
LOT 5, BLOCK 6
C I j
PARADISE VALLEY
I 1\
T \
Vacant
� O
/ \ 2
r�
6
A
} �
1
2
3
�..�gro�lLi
•64q
b+P�F.•0F
d* • 49� Y *�o
AREA
MAP
......
�
D iJ .
SCALE
1 = 100'
O�i�.:•//j4381
•
I m�
I 3 i `•� E ' ��•i
s: 6 4 �
i +'e id
I �-.e o F o o ,��i\�i�••
9A go'_g o X50
3Y = E c x
c 2'o $X
Z
CO U0
Li
M Y� r
�>-m� I w
v I €y J
c
ti0 Lu
r U
m
LLJ OJ
V) I a
p I
Q U
ry I LL
n I D
I
I
I
I s®
I
I v�
503' 14'OO�E dJ
103.03 '/6\
�d
0,y
LOT 4, BLOCK 6, PARADISE VALLEY SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Four Bedroom Home 5' Wide Trench System
Perc. Rate: 1-5 Min./Inch 1,500 Gallon STEP Tank
Application Rate: 1.2 GPD/SF .5' Drainfield Rock
4 Bedrooms' 150 GPD/Bedroom = 600 SF Absorption Area
600 SF/1.2 GPD/SF/5 SF (Width)= 100 LF Trench Length
THEREFORE: Construct 3 Trenches a Total of 100' Long x 5' Wide x .5' Effective Depth.
Flow Line Elevation in Trenches to be .5' Below Original Ground Surface. Total Depth to be
1.0' Below Existing Ground. Provide 3' Cover Over Absorption Trench and 4' Cover Over
Septic Tank. Remove Organic Material as Necessary and Replace with Clean Coarse Sand.
Existing Ground
4" Topsoil and Seed
Natural Backfill
(3' Min.)
_ Geotextile
6 t
6" 0-
5 -
Remove
5'Remove Organic Material
As Necessary & Replace
w/Clean, Coarse Filter Sand
1" Perforated
PVC (Holes Down)
3/16" Holes @ 3.5' Spacing
TYPICAL 5' WIDE TRENCH SECTION
(NO SCALE)
NOTE: Grade Area Over Trench to Drain Away.
Minimum 6' Separation From Bedrock.
Minimum 4' Separation From Groundwater.
Minimum 100' Separation From Private Wells in the Area.
Minimum 100' Separation From Surface Water or Streams.
LOT 4, BLOCK 6, PARADISE VALLEY SUBDIVISION
ALTERNATE SITE
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Four Bedroom Home 5' Wide Trench System
Perc. Rate: 1-5 Min./Inch 4 Bedroom Advantex Treatment System
Application Rate: 4 GPD/SF .5' Drainfield Rock
4 Bedrooms' 150 GPD/Bedroom = 600 SF Absorption Area
600 SF/6 GPD/SF/5 SF (Wdth)= 20 LF Trench Length
THEREFORE: Construct an Absorption Trench a 20' Long x 5' Wide x .5' Effective Depth.
Flow Line Elevation In Trench to be .5' Below Original Ground Surface. Total Depth to be
1.0' Below Existing Ground. Provide 3' Cover Over Absorption Trench and 4' Cover Over
Septic Tank.
Existing Ground
I
4" Topsoil and Seed
Natural Backfill
(3' Min.)
_ Geotextile
5'
WIDE TRENC
(NO SCALE)
1" Perforated
PVC (Holes Down)
3/16" Holes @ 3.5' Spacing
41M
LI
Grade Area Over Trench to Drain Away.
Minimum 6' Separation From Bedrock.
Minimum 4' Separation From Groundwater.
Minimum 100' Separation From Private Wells in the Area.
Minimum 1 00'Separation From Surface Water or Streams:
4ft
MCIUELLMXR9
No. CES l
Municipality of Anchorage �* .''U4�Jy!'vf
Development Services Department e..•.•�•�• ••••�A••
Building Safety Division / .......... ..�(•;
On -She Water and Wastewater Program "". •"
4700 South Bragaw St. 0, o .MIOWL ! ANMS0N' W
P.O. Box 195650 Anchorage, AK 99519-6650I •, CE -4381 •: V�?.
www.cl
k.us �9 0��*4 "Y
t907 04 ) �4 V.
�rESSt�t 4'
Soils Log - Percolation Test
Performed For. _Dale Performed: 3 O $
Legal Descri lion:. Paridi! a Valley SUbd., Lot 4, Bik 6 Range, Section:,
, Site Plan
(Feet) OG
1-
oL
3-
4-1
5-
7-
4-
5-
11-
12-
13-
11-
12-
13-
15-
16-
17-
18 -
15-
16-
17-
18 -
COMMENTS
COMMENTS
WAS GROUND WATER
ENCOUNTERED?
S
IF YES, AT WHAT DEPTH? L
Depth to Water After v p
N
Monitoring? WA1M E
Date: 7 :p$
Reading
Date
Gross Time
Net Tune n
Death to Wales(
Net Drop
S Joe;
IQ34y
4 -'5v�
2c'.0V18
ZC: 10
.ir3
'LSSo
ZI 'CI'Di0
��
o. q4
PJ
PERCOLATION RATE Yom'✓ ImMe✓nen) PERC HOLE DIAMETER o0i,'
TEST RUN BETWEEN 3• y FT AND —&C FT
PERFORMED BY: I CERTIFY THAT THIS TEST WAS
PERFORMED IN ACCC' R ANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
Municipality of Anchorage
Development Services Department
Building Safety Division
i2 On -Site Water and Wastewater Program
4700 South Bragaw SL
P.O. Box 195650 Anchorage, AK 99519-6650
www.ci. anchorage ak.us
(907) 343.7904
Soils Log - Percolation Test
Performed For.
Leal on:
Depth
eU
* (49U_EE fN---AQ .*
9. ANDERSON
-4381
/9 -or.
_ `ii
_Date Performed:
Paridise Valley Subd., Lot 4, 131k.6 - .i Range, section:,
Slnne Site Plan
3-
4 _
5
6-
-t�<a rock
COMb1ENTS 110'
Reading
Date
YJAS GROUND WATER
9-
Depth to Water
ENCOUNTERED? 1
5
10-
IF YES. AT WHAT DEPTH? f0ge %C, 0
DepthWater After P
11-
Slo
Mon
Monitoring? E
.ice
12-
Dale:
COMb1ENTS 110'
Reading
Date
Gross Time
Net Time a
Depth to Water
Net Drop 4
20 16.33I'L
Slo
o.ul';L
2 '
2r32,
4'1
PERCOLATION RATE `r' -Li (m Os/mth) PERC HOLE DIAMETER
TESTRUNBETWEEN 'L•Iy FT 'AND. FT
PERFORMED BY: AA� . I CERTIFY THAT THIS TEST WAS
PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 4, BLOCK 6, PARADISE VALLEY SUBDIVISION
GENERAL:
The scope of this project includes the procurement and installation of a
new 1,500 gallon STEP Tank at the location shown on the site plan.
Work also includes the construction of 3 new absorption trenches a
total of 100' long by 5' wide by .5' effective depth also shown on the
Site Plan. A 1.25" PVC line must be placed between the lift station
and the new absorption trenches. The distribution pipe for the trench
will be placed at .5' below the ground surface. The total depth of the
trench will be 1'. A minimum of 3' of cover must be placed atop the
trench. A minimum of 4' of cover is required over the Septic Tank and
Lift Station.
2. Construction shall be in accordance with the approved site plan,
design drawings, Municipal Permit with any special provisions or
conditions, and all applicable State and Municipal Wastewater
Disposal Regulations.
3. The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the
location of all lot lines. Contractor is also responsible to verify the
separation distance from the well on this and adjacent lots. Survey
notes must be furnished detailing placement and location of the septic
system.
4. Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
5. Contractors installing wastewater disposal systems must be certified
by the Development Services Department Building Safety Division On -
Site Water and Wastewater Program for system installations. Owners
installing their own systems must receive prior approval from the On -
Site Water and Wastewater Program before beginning system
installation.
SEPTIC TANK/LIFT STATION INSTALLATION
The 1,500 -gallon STEP Tank must be obtained from a Municipally
approved septic tank manufacturer.
2. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
Lot 4, Block 6, Paradise Valley Subdivision
November 11, 2008
Page 2 of 3
3. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
4. Tanks installed without 4' of cover shall have a minimum of 2" of direct
burial insulation.
5. A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drain field.
6. Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAIN FIELD CONSTRUCTION:
The drain field shall be constructed to the dimensions shown on the
design. The bottom of the bed shall be within 2" of level.
2. Distribution piping must be placed level with perforations down atop a
level bed of drain field rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drain field
rock and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion below ground must be perforated.
5. Contractor shall verify the septic tank and drain field are a minimum
100' away from any private water wells in the area, 150' from a Class
"C" Well or 200' from any community well.
6. Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trenches to drain away.
8. A minimum 2' of accepting soil is required below the drain field rock for
a 5' wide trench. All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
The lift station must be constructed by a municipally approved septic
tank manufacturer. An Orenco 20 OSI 05 HHF-5 pump is
recommended.
Lot 4, Block 6, Paradise Valley Subdivision
November 11, 2008
Page 3 of 3
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated
and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
5. A permeable geotextile fabric (Typar. Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5' to 2.5' in diameter with less than 3% passing
the #200 sieve.
FILTER SAND SPECIFICATION:
1. Material for Filter Sand must be classified as a masonry sand and
meet the following gradation:
50% or More Passing the No. 4 Sieve
2% or Less Passing the No. 100 Sieve
1 % or Less Passing the No. 200 Sieve
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These
inspections must be conducted under the supervision of at professional
engineer registered in the State of Alaska. The first inspection must be
conducted after the excavation of trenches, beds or pits and before the
installation of any gravel. A septic tank may be set in place, but may not
be backfilled.
The second inspection must be conducted after the placement of the
geotextile fabric, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as -built of the completed system.
Pisonth Keyuravong
13201 Westwind Drive
Anchorage, AK 99516
May 21, 2009
Municipality of Anchorage
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road
Anchorage, Alaska 99519-6650
Re: Owner Installation of On -Site Wastewater Disposal Systems
Permit No. S W090008
Dear Sir:
1 am a registered professional engineer in state of Alaska, my background
knowledge and experiences are in the industries design and constructions, these includes
mechanical, electrical and process. I am also an experience earth mover machine
operator.
I have completed my training, passed examination and certified as an on site
waste water septic system installer from Alaska Department of Environmental
Conservation. I have successfully design and installed the onsite 1500 gallon bed septic
system in Fairbanks during 2002. The system is presently working successfully.
With my background knowledge, experiences, guidelines, codes and standards
from the Department, and having Mike Anderson, P.E. who has designed and will inspect
during construction and will certify as built for the City for approval, I can assure the
Department that the installed system will meet or exceed the standard set by Municipality
of Anchorage and State of Alaska.
Please grant an owner installation of onsite wastewater disposal systems for my
property located at: 18000 Norway Circle, Anchorage, Alaska.
Sincerely,
V-etl
Pisonth Keyuravong,P.E.