Loading...
HomeMy WebLinkAboutCONIFER HEIGHTS BLK 2 LT 14Conifer Heights Block Lot 14 #015-093-23 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: _______________ Date of Issue: ____-____-____ Parcel Identification Number: ____-____-____ Legal Description Block Lot Property Owner Name & Address: Pump Installation Date: _____-_____-_____ Pump Intake Depth Below Top of Well Casing: __________ feet Pump Manufacturer’s Name: ___________________________ Pump Model: _____________________________________ Pump Size: ____________hp Pitless Adapter Burial Depth: _________ feet Pitless Adapter Manufacturer’s Name: _________________________ Pitless Adapter Installer: ____________________________ Well Disinfected Upon Completion? XX Yes No Method of Disinfection: _____________________________ Comments: Pump Installer Name: __________________________________ Company: ___________________________________________ Mailing Address: ______________________________________ City: ___________________ State: __________Zip: _________ Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 8:25 L Street- Anchorage. Alaska 99501 Telephone 264-4'/20 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT · [] UPGRADE MAILING ADDRESS ~ DISTANCE TO: [0~~ ~ M~ufacturer~ Mete~ No. ofcompartme.t, ~ /~O IF HOME.DE: Length W,dt~ ~pth PERMIT ~ DISTANCE TO: ~ DISTANCE TO: Building foundation Se~r li~e Septic tank Absorption erea(s} OTHER ~'~ PIPE MATERIALS t REMA S 72~13 {Rev. 3178) ) I-'lLIr--I T C 1' Fr'~L 1' T'T' C'F RI",II__-~HC '~:F-IL~E ~[~'~9 '~ DEPRRTHENT OF HERLTH FIHD ENVIRONHE~'!TFIL PRUTEC:TIOH "~-~-"~ · . 825 'L' STREET., RHCHORF~GE., AK. 9~501 -- ~----/ I..IELL F41'4D ,_"~1'-4--S I TE SEI-IEF: PERt-1 1' 1~----~.-.'~x/~ j_']9 F'ERMIT fiE1 < 79025E: ) 0,0/'-, "'~'-/'~¢- LOC:AT I ON CONIFER HTS LEGAL L14 E:2 CONIFER FITS LOT SIZE ~SQURRE FEET T'¢F'E OF SOIL FIBSORBTIOrl SVSTEH IS: TRENCH HRMIf'IUM NUMBER OF BEDROOMS : 4 SOIL RRTING 7HE RE6!LIIRED SIZE OF THE SOIL RBSORPTIOfI SYSTEM IS: [:. [E P T !-t = :1.£~ L E 1'-4 I.S T H = 51¢ G F;: R'...' E i_ P_-, E F' T !-I =~ 5. THE LENGTH DIf'IENSION IS THE LEHGTH (IN FEET) OF THE TREfICH OR DRRINFIELD. THE DEPTH OF Ft TRENCH OR PIT IS THE DISTFifICE BETHEEfl THE SURFFiCE OF THE GROLIHD RN[:, THE BOTTOM OF THE EXCFIVFITION (Ill FEET). THERE IS riO SET HIDTH FOR TRENCHES. THE GRFIVEL DEPTH IS THE HINIHUM DEPTH OF GRI-3VEL E:ETNEEfl THE OUTFRLL PIPE FiNE', THE BOTTOH OF THE EXCRVRTION (IH FEET). f~:bZm2m_l I F;EC, SEPT I C TR I'-.i t=.-:. S I ZE= -1 2:-~_-~£~ GRLLLnI'-.I'L----_. F'EF:MIT RPPLICFiHT HRS THE RESPOHSIBILIT'¢ TO IHFORM THIS DEF'RRTMENT [:,URIHG THE IHSTFiLLRTIOfl INSPECTIOfIS OF RfI'¢ HELLS Fi[>..TRCEHT TO THIS PROPERTY AND THE HUMBER OF RESIE:,EHCES THAT THE WELL I,IILL SERVE. Tl4ra < 2 ) I I'--ISPEOT I 01'-,15 RF-:E F-:E _r--ibm I F-.'E 13, E:RC:t(FILLING OF FiNY SYSTEH HITHOUT FINRL IHSPECTION RHD FiF'PF:OVFIL BY THIS DEF'Fi~TMENT MILL E:E SUB..lrECT TO PROSECUTIOH. I'IlIIIMUM DISTRfICE BETI,IEEN R PlELL FifID RHY OH-SITE SEHRGE DISF'OSRL SYSTEH IS lO0 FEET FOR R PRIVFITE ~IELL.; OR 150 TO 200 FEET FROr'I R PUE:LIC NELL DEPEf~DING UPON THE TYPE OF PUBLIC HELL HELL LOGS RRE REQUIRED RfID MUST BE RETURHE[:, TO THE [:,EF'RF'TI.1EfIT I,IITHIN 30 DRVS OF THE HELL COMPLETION. OTFIER REQUIREHENTS MFI'T' RPPLV. SPECIFICFiTIONS RfID COHSTRLIC:TIOfl DIRGRFiMS FiRE R'.,,'RILFiE:LE TO IHSURE PROPER INSTFiLLFiTIOH. F'EF-:f-1 I T E×P I RES I2-.ECEY'IBER 3'i.. l_'S-" 79 I t: FORTH BY THE HUHICIPFiLITM OF RNCHCiRRGE. 2: I P~ILL IfISTFILL THE SYSTEM IN FICCOF:DRfICE HITH THE CODES. . 2: I UNE:,ERSTRND THAT THE OH-SITE SEHER SVSTEM I'IAV REQUIRE EHLRRGEMEHT/IF THE PESIDErlC:E IS REMCiE:,ELED TO IHC:LU[:,E HORE THRH 4 BEDROOMS. ~¢/~/~---- RPPL I~NT FiOE:ERT MILE, ' I CERTIFY THAT I RM FFIHILIFIR HITH THE REOUIREMEHTS FOR OH-SITE SEHERS FIflD HELLS FiS SET HUN I C~'~ F::'I-3L 't T¥ OF' ~:~ ~4/"~-! 0 R i:t L] , DEPARTMEN~ OF HEALTH AND ENVIRONMENTAL PROTECTION, , ' 825' 'L' STREET, ANCHORAGE, AK. 9.9501 264-4?20 WELL AND Or~--SITE SEI--JER: PERP1 PERMIT riO. LOCATION TYPE OF SOIL ABSORBTION SYSTEM IS: LOT SIZE~dO 6 SQUARE FEE~ MR;<IMUM NUMBER OF BEDROOMS = ~ SOIL RATING THE REQUIRED SIZE OF THE. SOIL RBSORPTIOI'I SYSTEI"I IS: DEF'TH= /0 EEt-4GTH= ~"'0 ~RR%-'EL DEPTH= THE LENGTH DIHENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAINFIEED. THE DEPTH OF A TRENCH. OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE OROUHD AND THE BOTTOM, OF THE EXCAVATION (IN FEET). THERE IS NO SET WIDTH. FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFRLL PIPE AND THE BOTTOM OF THE EXCAVATION (IH FEET). REQLI I RED SEPT T I; TANK '-='~ I----"E= /~0 GRLLt_'-IN$ PERMIT APPLICANT HAS THE. RESPONSIBILITY TO INFORM THIS DEPFIRTMENT DURING THE INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. ------ TNm3 ( 2 ) '1' t~l_C;,PECT I C~t~i$ ARE REQLI I F;ED BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WIL[i BE SUBJECT TO PROSECUTION, MINIMUM DISTANCE BETWEEN'A WELL AND R~IY ON-SITE SEWAGE DISPOSAL SYSTEM IS · 00 FEET FOR A PRIVATE WELL; OR 150 TO 200 FEET FROM R PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. WELL LOGS RRE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN 30 DAYS OF THE WELL COMPLETION. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS ArID CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. F'ERf'I I T EXP I RES DECEr'IBEF.' ~-1-: .- '1 §7--~.~. I CERTIFY THAT 1: I RM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS RS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. 3: I UNDERSTAND THAT THE 'ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN 8 BEDRO0~IS. Applicant / - 4040 "B" STREET ANCHORAGE, ALASKA 99503 (907) 278-1551 April 16, 1979 W.O.# A18820 Grid: 2440 ~. Neal Burleson 3318 Illiamna Anchorage, AK .99503 Subject: Percolation Test - Lot 14, Block 2, Conifer Heights Subdivision Dear Mr. Burleson: At your request we have completed a percolation test on Lot 14 Block 2 of Conifer Heiqhts Subdivision in the hillside area of Anchorage. The boring location is shown on Figure 1. It was drilled using a continuous flight solid stem auger drill rig mounted on a Nodwell carrier. The rig is owned and is operated by Denali Drilling Inc. Drilling was supervised, the test hole logged and percolation test performed by Mr. O.M. Hatch, Alaska Testlab geologist. The log of the test hole is included as Table A'of this report. In interpreting the log, it would be helpful to utilize the explanatory information contained on Sheets 1-3 of the report. ~'~en driling was completed a 3/4" slotted PVC pipe was inserted in the hole to aid in determining the free water level. For the percolation test the test hole was filled with water and left overnight to saturate. On returning the next day, the hole was refilled with water and the water level carefully monitored for the next 60 minutes. This procedure is not a standardized percolation test, however, we understand the Municipality of Anchorage, Dept. of ]]ealth & Environmental Protection prefers performed in this manner to evaluate the site for proposed on-site sewerage systcm. ~. Nea~ Burleson April 16, 1979 Page 2 Using the above test ~he observed minimum percolation was 5 minutes per inch. We suggest that the system the on~ wastewater system be designed for an absorptio~ area ~l~u square feet per bedroom. This recommendation is based~on criteria in the "Manual of Septic Tank Practice" U.S. Dept. of llealth Education & Welfare, Public }lealth Service. We recommend the absorption trenches be inspected prior to installing the system as the above recommendations are based on the result of the six-inch test hole. The seepage trench will provide a much clearer picture of the subsurface conditions than the test hole. If the soil conditions turn out to be more favorable than predicted, it may be possible to economize the system by reducing'the length of the trench. Conversely, if the soil appears tighter than anticipated, then it may be necessary to enlarge the system or to use an alternate location on the lot. The chief value of the drill hole is in establishing the feasibility of on-site systems, while examination of the trench is expected to provide better specific information. The following items are attached and complete this report: Table A Sheets 1-3 Site Plan Test Boring Log Standard Explanatory Information We trust this report meets your present needs. If we can be of further service please feel free to contact us. Sincerely, ALASKA T E S TLAB James R. Finley, Jr. Geotechnical Engineer Approved: Melvin R. Nichols, PP. Laboratory Manager · JRF :mfm Attachments Test llole ~1 Table A NO ~A18820 Date: 4r9-79 Logged by: O.M.Hatch Depth in Feet From To 0.0 1.0 1.0 2.5 2.5 16.0 Soil Description Brown Peat, damp, soft, Pt Brown Gravelly very Sandy Silt, damp, stiff, non-plastic, ML F-l, brown slightly Silty Sandy Gravel with trace of cobbles, damp, medium dens----6; maximum particle size ~pprox..6", GM Bottom of Test }lole: Frost Line: Free Water Level: 16.0 ft. 2.0 ft. None observed Sa. NO. Depth 1 5.0 2 10.0 3 15.0 Type of Sample Unified G GM G GM G GM · Remarks: 1. 3. 4. 5. 6. Type of Sample, G=Grab, SP = Standard Penetration, U = Undisturbed. Dry Strength, N=None, L=L6w, M=Medium, It=lligh. Group refers to similar material, this s~udy only. General Information, see Sheet 1. Frost and Textural Classification, see Sheet 2. Unified Classification, see Sheet 3. M-W DRILLING, Inc. P.O. Box,l-1224 · 1310C International Airport Road (907) 274-46l I ANCHORAGE, ALASKA 99509 DRILLING LOG Well Owner Robert Mtlby UseofWell Domestic Location (address of: Township, Range, Section, if known; or distance main road Lot 14 Block 2 Conifer Heights, Anchorage Size of casing. 6" Depth of Hole Static water level 200 ft. ~a'~ Screen ( ); Perforated ( Describe screen or perforation N/A Well pumping test at 1/2 gallons per ~Y~i~)'~ (minute) for 1 of drawdown from static level. Da're of completion 7/20/79 500 feet Cased to 182 feet (below) land surtace. Finish of well (check one) open end ( XX ); ). hours with 100% ~. WELL LOG Depth in feet from ground surface Give details of formations penetrated, size of material, color and hardness 0 .TO 2 Casing stickup 2 .TO Organics __.TO __.TO __.TO. __.TO__ TO__ __.TO .TO. .TO. .TO. · .TO. __.TO. .TO .TO 4 11 26 26 36 36 65 ._6.~ 157 157 182 182 500 11 Silty gravel Loose gravel Sand __Loos~_gr~vel _~an~_gr~a~el.-lmose Hard pan Bedrock: water see_~ps in sporadic I--CUSTOMER 825 L St~t - Anchor~, Alaska 99501 D:WS:O. AUG 1 0 1979 Telephone 2~720 RECEIVED ~ REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTION$: Complete all parts on page 1. Incomplete request~ will not be processed. Pleas~ allow ten (10) days for processing. PROPER,T E MAILING ~[DORESS MAILING ~DDRESS 4. REALTOR/AGENT MAILING A~D~ESS STREET LOCATI~'N 6. TYPEOF RESIDENCE SINGLE FAMILY MULTIPLE FAMILY 7. WATER SUPPLY ::'~ INDIVIDUAL* COMMUNITY I-'1 PUBLIC UTI LITY 8. SEWAGE DISPOSAL SYSTEM INDIVIDUAL/ON-SITE** PUBLIC UTILITY PRONE PHONE IPRONE NUMBER OF BEDROOMS r--I One r--I Four r-I' Other r-i ;Two I'-I Five ~ ~ ,Thr~e ~ Six · ATTACH WELL LOG. A well log is required for all wells drilled since :June 1975. For wells drilled prior to that date, give well de~th' (~ttach log if ~vailable.) '·If ind!vidual/on-site, give installation date ,~...~ If ~yste~ is over two (2) years old an adequacy test~required - by this Department. ' I NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. ;. 72~)10{3/781 THIS SIDE FOR OFFICIAL USE ONLY DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TiME DATE DATE DATE iNSPECTOR .~ _ , iNSPECTOR INSPECTOR DIRECTIONS: 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS r-I SINGLE FAMILY [] ONE [] THR~E' i [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER suPPLY [] . INDIVIDUAL . · DEPTH OF WELL . [] COMMUNITY , . DATE DRILLED ' . [] PUBLIC UTILITY , Connection Verified LOG RECEIVED , 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER []INDIVIDUAL/ON -SITE DATE iNSTALLED I'-IPUBLIC UTILITY : ' [ Connection Verified INSTALLER []Septic Tar~k~or [:]Holding Tank Size: /~L,~J, IfTankishomemade SOILSRATING '- give dimensions:' ' ' ].~) TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4. DISTANCESwELI~TO: ,/00 E. COMMENTS [I~...~APPROVED FOR ~ BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPROVED DATE BY (Titte) LEGAL DESCRIPTION 72-010 (Rev. 3/'/8) CERTIFICATE FOR A Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 OF ON-SITE SYSTEHS APPROVAL SINGLE FAHILY DWELLING Parcel I.D. 015-093-23 1. GENERAL INFORMATION Expiration Date: / - //-//' Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address CONIFER HEIGHTS S,/D; BLOCK 2, LOT 14 7951 PORT ORFORD DRIVE * ANCHORAGE, AK * 99516 WARREN dACKSON Day phone ,546-5118 7931 PORT ORFORD DRIVE * ANCHORAGE, AK * 99516 Day phone CHARLES BLALOCK W/ PRUDENTIAL Day phone 563-5500 3801 CENTERPOINT DR, #200 * ANCHORAGE, AK * 99503 Unless otherwise requested, COSA will be held by DSD for pickup. NUMBER OF BEDROOMS: 5 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well [] Individual On-site [] Individual Water Storage [] Individual Holding tank [] Community Class Well [] Community On-site [] Public Water System [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this appfication, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 5701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being sen/ed by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. DSD SIGNATURE Approved for ~ Disapproved. Conditional approval for bedrooms. -~ bedrooms, With the following stipulations' Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory (Rev. 11/05) Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other · Original Certificate Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Legal Description: CHECKLIST CONIFER HEIGHTS S/D; BLOCK 2, LOT 14 WE LL DATA Well type F;RIVATE If A, B, or C provide PWSID# . Date completed 7/20/1979 Sanitary seal (Y/N) YES Total depth 500 ft. Cased to 182 ft. Parcel ID: O /,~"-' O q 3 -,,~, ~ Date of test N/A Well Log (Y/N) Wires properly protected (Y/N) Casing height (above ground) YES YES 12+ in. FROM WELL LOG 7/20/1979 Static water level 200 Well production 0.5 WATER SAMPLE RESULTS: Coliform ~colonies/100 mi. .IL. B. SEPTIC/HOLDING TANK DATA AT INSPECTION 8/11/2010 330 ft. g.p.m. 0.41 g.p.m. g./L. Date of sample: 8/20/2010 Other bacteri~[al~mm~v, olonies/100 mi. Collected by: GEG Ltd. Tank Type/Material Tank size 1250 gal. Foundation cleanout (Y/N) YES Date of pumping ABSORPTION FIELD DATA Date installed 8/7/1979 Length 50 ft. SEPTIC/STEEL Number of Compartments 2 Depression over tank (Y/N) NO per. ~*BELOW EXISTING GRADEI Soil rating (g.p.d./ft2o~ 150 Width 5-8 ft. Date installed 8/7/1979 Cleanouts (Y/N) YES High water, alarm (Y/N) N/A ISAACS PUMPING System type TRENCH Gravel below pipe 6 Total depth * 13.9 ft. Eft. absorption area 600 ft2 Monitoring tube YES Date of adequacy test 8/1'1/2010 Results (Pass/Fail) PASS Fluid depth in absorption field before test 0 in. Water added 450 gal. Elapsed Time: - min. Final fluid depth 0 in. Absorption rate >= Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN Depression over field NO For 3 bedrooms New depth 0 in. 450+ g.p.d. If yes, give date - D. LIFT STATION Date installed "Pump on" level at.__.in. ~ ~ Cycles tested E. SEPARATION DISTA~NCES SEPARATION DISTANCES FROM WELL ON LOT TO: Size in gallons Manhole/Access (Y__~N_) _----- ''Pump off" leve. L~~ High water alarm level at 100'+ Septic tank/lift station on lot Absorption field on lot 100'+ Public sewer main N/A Sewer/septic service line 25'+ Animal containment areas 50% in. Meets alarm & circuit requirements~ On ~djacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout Holding tank N/A Manure/animal excrete storage areas N/A 100'+ Building foundation Water main Wells on adjacent lots SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: 5'+ Property line 5'+ N/A Water service line, 10'+ 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Absorption field 5'+ Surface water. 100'+ Property line 10'+ Building foundation, 10'+ Water service line 10'+ Surface water 100'4- Curtain drain NONE KNOWN Wells on adjacent lots 100'+ cOMMENTS Water main N/A Driveway, parking/vehicle storage 10'+ G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date ~/3,"//~ COSAFee$ 1~ ~ Date of Payment Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Water Well Advisory Certificate of On-Site Systems Approval (COSA) # 101239 During a recent COSA on-site inspection and test of the potable water supply well on Block 2, Lot 14 of Conifer Hts. subdivision, the well's productivity was determined to be 0.41 gallons per minute. The minimum well productivity required by this Department (AMC 15.55) for a 3-bedroom residence is 0.31 gallons per minute. Although the subject well currently exceeds this minimum requirement, all parties concerned are advised that the production capacity of the well may fluctuate. Restriction of non-critical water uses such as washing cars and watering lawns and gardens may be required. This advisory must be attached to all copies of the subject Certificate of On- Site Systems Approval. SGS ReL# 1104318001 Client Name Garness Engineering Group, Ltd Printed Date/Time 08/26/2010 13:52 Project Name/# 7931 Port Orford dr Collected Date/Time 08/20/2010 13:20 Client Sample ID 7931 Port Orford dr Received Date/Time 08/20/2010 13:40 Matrix Drinking Water Technical Director Stei~hen C. Ede Sample Remarks: Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date Init Metals by ICP/MS Arsenic ND 5.00 ug/L EP200.8 C (<10) 08/23/10 08/24/10 NRB Waters Department Total Nitrate/Nitrite-N ND 0.100 mg/L SM20 4500NO3-F B (<10) 08/23/10 AYC Microbiology Laboratory Eo Coli Negative 1 100mL SM20 9223B A 08/20/10 SDP Total Coliform Negative I 100mL SM20 9223B A 08/20/10 SDP ~m~ ~O--q ---qO .-ro ~m~ m --t 7~m m"rl m o~ O~ -0 m Z z 0 0 z m 03 m m 0 ~9.2 / N N19o N o N N N