HomeMy WebLinkAboutTHE SHIRE LT 2 THE SHIRE CONDOMINIUMSOnsite File The AWWTS system has been changed to a CAT II configurationand has beenapproved a bedrooms. -See the attached engineers letter. GARNESS ENGINEERING GROUP, Ltd CIVIL & ENVIRONMENTAL ENGINEERS December 8, 2017 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Rd. P.O. Box 196650. Anchorage, AK 99519-6650 (907) 343-7904 Attn: Deb Wockenfuss 0,ua S Advanced T-cv[ment Sy tem � rr.z+ D -: Ref: The Shire S/D; Lot 2 - Memo concerning converting CAT III AWWTS to CAT II AWWTS septic system Ms. Wockenfuss: The permitted septic system was installed on the referenced property in 2007 and started -up in the summer of 2008. The system was originally installed to serve a 4 bedroom single family home with future plans to convert the home into a 7 bedroom duplex. In 2009, an addition was added to the home which made the structure into a duplex. Based upon MOA tax records, the total number of bedroom is now 6 bedrooms. On 11/9/2017, the drainfield monitoring tubes were checked and found to be dry by GEG Consultant, Jody Maus. In order to simplify the operation and maintenance of the system, we are proposing that this unit be permanently configured as a CAT I I system Our justifications are as follows, • The receiving soil f o r T H#2 perked at 5 minute per inch and the CAT I I soil application rate is 4.0 gpd/sq.ft. • The duplex has a total of 6 bedrooms, so 225 sq./ft. of absorption area is what we are proposing for this CAT II system (900 gpd/4.0 = 225 ft2). The existing 2007 drainfield has 480 sq./ft of absorption area. The following information should supersede the GEG's Inspection Report dated 7/30/2008 and approved on 8/7/2008. - Number of bedrooms: 6 bedroom (total) — This is now a duplex - This is a Quanics Cat 11 Aerocell System At this time we request that your department allow for the Quanics system at this property to be operated in a CAT II configuration. Upon your concurrence, we will 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com Page 2 of 2 insure the jandy valve is e i t h e r I eft i n t h e open position or completely removed, and we will place a CAT II sticker on the control panel. ly, Jeffrey A. arness, E., M.S. President 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www. garnessengineering.com ALA-1-%.,SK\,ASTIL`�'�[`E Sarah Palin, GOVERNOR 555 VA DEPT. OF ENVIRONMENTAL CONSERVATION ANCHORAGE, AK 99501 DIVISION OF AVATER Phone: (907)269-7519 WASTEWATER DISCIIARGE PROGRAM Fax: (907) 269-3487 hup://www.suu.akus/dec/ April 22, 2009 Jeffrey A. Gamess, P.E. Gayness Engineering Group, Ltd. 3701 E. Tudor Road, Suite 101 Anchorage, Alaska 99507 Re: The Shire, Lot 2-Chugiak near Eagle River -Final Approval of an Advanced Wastewater Treatment and Onsite Soil Absorption System and Create a Class "C" Public Water System-ADEC Plan Tracking Number 7668 Dcar Mr. Gamess: On April 20, 2009 the Department received an engineered plan submittal for an existing advanced onlot wastewater treatment system serving a two -unit condominium (with a total of seven bedrooms). A new 2,500 gallon septic tank and two 650 gallon per day Quanics Aerocell Units were installed along with a new soil absorption system (450 square foot bed). The soils information for the lot resulted in percolation test results of 5 -minute per inch. The advanced treatment (level III) and the existing soils being SM & GM type would require a 350 square foot bed (minimum). The use of a 450 square foot bed is satisfactory. The Class "C" public water system was reviewed, the water samples and the separation distances were within standards and are acceptable. This information will be on file with the wastewater system. The Department has reviewed the engineered plans submitted for the onsite wastewater disposal and treatment system in accordance with Wastewater Regulations 18 AAC 72.240 final operational approval for the proposed system is hereby issued. A final approval completed "Certificate to Construct" for the community wastewater system is enclosed. Please use the referenced plan number in correspondence regarding this System. This approval does not imply the granting of additional authorizations nor obligate any state, federal or local regulatory body to grant required authorizations. Any person who disagrees with this decision may request an adjudicatory hearing in accordance with 18 AAC 15.195- 18 AAC 15.340 or an informal review by the Division Director in accordance with 18 AAC 15.185. Informal review requests must be delivered to the Division Director, 555 Cordova Street, Anchorage, Alaska 99501, within 15 days of receiving the decision. Adjudicatory hearings requests must be delivered to the Commissioner of the Department of Environmental Conservation, 555 Cordova Street, Anchorage, Alaska 99501, within 30 days of the decision. If a hearing is not requested within 30 days, the right to appeal is waived. Thank you for your cooperation. If you have any questions please do not hesitate to contact me at 269-7519. Respectfully, William R. Rieth, P.E. Environmental Engineer Enclosure: As stated cc: William Smyth, WW, w/o enc. STATE OF ALASKA DEPARTMENT OF ENVIRONMENTAL CONSERVATION CONSTRUCTION AND OPERATION CERTIFICATE FOR DOMESTIC WASTKIVATER DISPOSAL SYSTEMS A. APPROVAL TO CONSTRUCT I1 DEG /-� %% Ala* •Pius 7668 Plans for the construction or wastewater disposal system. by _ 6.aAir.&44r Xpw ,G ❑ approved as submitted F eu been reviewed and are s.7,% e) vy env om�q accordance with 18 AAaC 72.225 ta conditionally approved (see attached letter) Un C_.e. L�stas,�ess/9�i 7—Z 2, 6) Q9 (Renewing Engineer) ,Q,rC (Tac) (mof�7 - If applicant fails to construct, alter, install, or modify the system within two years of the date of approval to construct, approval is void, and plans must be resubmitted for Department review and approval. B. APPROVED CHANGE ORDERS Change (contract order number or descriptive reference) (R"iewmg Engineer) (Title) (Date of Approval) C. APPROVAL TO OPERATE The "Interim Approval to Operate" section must be completed and signed by the Department before this domestic wastewater disposal system is made available for use. Interim Approval to Operate: The construction of domestic wastewater disposal system was completed on The system is hereby granted 1ATERLtf APPROIAL TO OPERATE for 90 days following the completion date. It is illegal to operate the domestic wastewater disposal system beyond 90 days without Final Approval to Operate from the Department. (R\vrcwmg Engineer) (Tide) (Daic of Appm\'al) Final Approval to Operate: Record drawings and other documents submitted to the Department, or an inspection by the Department, has confirmed that the domestic wastewater disposal system was constructed in substantial conformance with the approved plans. The system is hereby granted FIXAL APPROI AL TO OPERATE. �/.✓..�.�/ h%��F..,vyatex�„e..�..�f�r.�c«cu� >g � 2� (Re\oew,ng Enginca) (1 nle) (U to of Appnr\al)� — Municipality of Anchorage lie Development Services Department Building Safety Division On -Site Water 8 Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage. AK 99519.6650 www.ci.anchorage.ak.us (907) 343-7904 Page 1 of 3 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number. SWO70186 PID Number. 051-293-55 Nome: DANIEL GRAY Wastewater System: ■ New ❑ Upgrade Address: 18518 TALARIK DRIVE a EAGLE RIVER, AK ABSORPTION FIELD Phone: No. of Bedrooms: (907) 360-4603 e4 0Deep Trench OShallow Trench ■Bed OMound OOlher LEGAL DESCRIPTION sae Rating: •e3.0 Gpo/sa FL ldd Depth 4«n «/poet rw6w 1' MAX TO TOP OF SAND Block: Lot: Subdivision: Do" to pi" bh«n Iron or" yede: Grow depth Smooth pipe: — 2 eeeTHE SHIRE SEE DWG. rt. 1.08 FL Township: Range: Section: — — — N eddb obw "Inel grade: Ware/ kwpn: 32 SEE DWG. n n cre.M eMh Numb« ofknee: DMI«we k.tee.n Snee: 5 WELL: ■ New ❑ Upgrade 15 i< 3 rt Cweeilico4on porde. AB.0 : PRIVATE Told opN:Cased 300 To:1pm,pag 44 Tad abearpt%o^ area: •480 PDe mdeNd: D 3034/ F-810/SCH 40 r< so. rt Drillr.. SULLIVAN WATER WELLS We odm d: 2/27/2007 st wwd« Le.el: 30 W~ DAN GREEN We Moo W: 11/14-17/2007 R Ywld: 2.5 Set At: 283 Co"n Negnt Above Cmune: 18+ TANK cptlp R M. SEPARATION DISTANCES 0Septic 0Holding OS.T.E.P. ■Other e To Septic Absorption Lift Holding blk/prlvote M'v'ladef�'' GREER cepealtr N 9� 2500 From Tank Fmld Station Tank sew« Ung Well 100'+ 100'+ 100'+ — 25'+ STEEL Nembe d mmp«tm.n4 2 Surface water 100'+ 100'+ 100'+ — — LIFT STATION Lot Line 5'+ 10'+ 10'+ — — gee M ql a 2500 twaetadanr: OUANICS GREER en M.d d: wro dl level oL Nqn ed« alarm ab Foundation 5'+ 10'+ 10'+ - - TIMER TIMER 44N pulnp Mab t Model: EW of kwpectkew Werned br: Curtain Droin NONE KNOWN P—TE-30—PLUS I RISING SON ELECTRIC Remarks: *SEPTIC SYSTEM SIZED FOR 7 BEDROOMS BENCH MARK t wn ad Deeerlpkera FOR POSSIBLE FUTURE ADDITION. TOP OF MANHOLE LID "THIS IS A OUANICS AEROCELL SYSTEM ***PREVIOUS LEGAL: T15N, RIW, SECTION 30, LOT 58A Mwnwd FM.otoa: 96.11 n ENGINEER'! SEAL Inspections performed by: GEG, Ltd. Dates: 1st 11/14/2007 ogOdO�� 4 o OF. A 0 2nd 11/15/2007 S�O�Q 3rd 11/17/2007 vv Development Services Department Approval °.:....9 . ...... ...:.*..0 D Conditional approval: Date: p, am ss —79$ :v 30 ON 4���� Prof Date: 7 -DS Reviewed and approved by: esslof Q�I�OQOpO (R«. 4/0e) 140, PERMIT NUMBER: SW070186 - AS—BUILT DRAWING PARCEL ID NUMBER: 051-293-55 FINAL GRADE TOP OF MAN . 95.11 HOLE .96.11 ,ANDY VALVE DUAL 650 OUANICS AEROCELL UNITS I INSULATION 617 IV TOP OF TANK - INLET . 91.16 TO DRAINFIELD INVERTOF BUNG INLET --_-------- TOP TANK . 90.87 ET .91.19 OUTLET -- Q 2500 GALLON S.T.E.P TANK ORGANICS PLACED OVER MOUND AND SEEDED TOP OF SAND . NOTE: ALL LINES ARE INSULATED WITH 2 INCHES OF INSULATION -FINAL GRADE . 98.49-99.75 %INSULATION / rFlLTER FABRIC 15' WIDE RELATIVE ELEVATION OF BOTTOM OF TEST HOLE • 68.67 (NO H20) ORIGINAL GRADE I 96.17 J.7 VERT OF DISTRIBUTION UNE . 96.25 (AVO.) BOTTOM . 91.1 GARNGSS GNGINGLRING GROUP, Ltd. vi'lo, ------CONSULTANTS3 GENERAL CONTRACTORSJM1 L 11OM 00•A fll[ 101 YICIIMULL M OOJ01 IIgK (OO1W1-011/ IM (001}UO-SSN OOR w�-p..pr��n DVA PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ••••••• .••••;.... DANIEL GRAY 907-360-4603 3 OF 3 I E-7951 65s: e`p� LEGAL DESCRIPTION: DRAWN BY: p$ THE SHIRE, LOT 2 K.D.M. OpO Bpd 13 s1o�°oma TYPE OF WORK: DATE: QQ4pO��oQo PROFILE AS—BUILT OF NEW SYSTEM 7/30/2008 . 01,05) \ \ m �\ "'• \ or r� cm I I \\ �,..•. \\� mMtntotn / \ o °• Ul Ln rn I I Y. cDn m \ >to \ _ — o�....�.. ,. I Z I I mU II 0 I g� 00 II z0 z O I INV) I I I I10 r)- A Y 00 // \,00 d N `• O CC ^' 0 v � z m Zb� I0 m z m m m r O < o O O p Q Q O -�I = -I CO {' O N O� m tD O� W •A D W v O� Ln N N Oo rn rs W c,, Do 00 CO moo cD (D — cD CD v 0) L4 CD (Ji W � (DD C) o) W N00 (Ln 0 WD Cn D) O O N N Na N 0 00 W _0060 4 CD W N O Cn N Ln CD W W N n � co oN N o CWC) CCD 00 •A• w rn `fid p0 UAIE: RAWN BY: O. .... ...... ...... 30/2008 K.D.M. 0 GAL DESCRIPTION: y }�• ••• •••• .•••• THE SHIRE. LOT 2 A. Ca ess:' O GARNESS ENGINEERING GROUP, Ltd. pp CE- 3 .`per TYPE OF WORK: CONSULTANTS &GENERALCOVTFACTORS Q e�,PO AS -BUILT DRAWING OF NEW SEPTIC SYSTEM ..,� w..ob..,..........,,.�y,.,OQe�e ''-7A- &lvSF,o°d PREPARED fOR:PHONE NUMBER: PACE: Do DANIEL GRAY 360-4603 2 OF 3 �4Opo�oo60 02/e5/2008 15:46 6882259 SULIVAN PAGE el/01 t'rerrittEbxtttt 09 by DOC Co. eco SULLIVAN 'WATER 'WELLS p.0. BOX 670272. CHUGIAK, ALASKA 99507-TLLEPHONE 609.2759 ADDRESS: LEGAL DESCRIPTION: rj R rL.J SSS - ? DAT[: "7 �f PERMIT NUMOER: �7o e r / Date of issue-ra.-lbw.--D3 TAX IDENTIFICATION NUMBER: O f ---=--�— Is well located at approved permit location? O Yes O No Method of Drilling: Mary O cable tool Depth o1 well: t)O Casing TypeL W1ti Thlekness—s Diameter All Incites. depth y feet Liner Type: .J Jw E Casing Stickup Above Ground:, J • feet Static water Level: 'So feet Recover Rate: _s,5._9pm Method of Testing:'""1�ra" ^'Well Intake Opening Typo: U open end C open twle O Screened: Startfeet Stoppod feet D Perforations Start to L,Stoppetl feet r7 Grout Type: iw CNofume Deptrc from [7 feet, to -.�J!12 feet Well Disinfected Upon Completion? 6.19 O No Method of Disinfection: Sy& n 12,W L' J L 11?1-4 Comments Te /.f 6.4$.au, neylar j: CNnt4C,in IDriller's Namo ATTENTION: It Is tho responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Ancnorooe: Department of Health d. Human Services and/or Department of Envlmnmental Conservation. MatSu Borough: Department of Environmental Conservatan. ARCTIC PUMP & WELL INC. Jim Sullivan, CPI PO Box 770197 oun m� Eagle River, AK 99577 aatano -� (907)688-2510 (907)258-2510 (907)745-2510 amv-^n eci.nel Pump Installation Log Well Drilling Permit Number: SW Parcel Identification Number: Date of Issue: Legal Description:The Shire Property Owner Name & Address: Lot:2 19401 Monastery [flock: Eagle River A 1C 0"77 Pump Installation Date: 6-6-08 Pump Intake Depth Below Top of Well Casing:283 Feet Pump Manufacturer's Name: Dempster Pump Modcl:LBF2-100-S2 Pump Size:1 hp Pitless Adapter Burial Depth: 10 feet Pitless Adapter Manufacturer's Name: Pitless Adapter Installer: U/K Well Disinfected Upon Completion? Yes Method of Disinfection: Chlorine Comments: Pump Installer Name: Arctic Pump & Well, Inc. Arctic Pump & Well, Inc. Page 1 of I 04 2008 12:36PM Rising Son Electric, Inc. 907-622-6777 Rising Son Qlectric, Inc. 14Qi6 \//ooc�lanJ give �=agle River, AK 99577 (907) 622.6777 August 4, 2008 Gamess Engineering Group Attn: Andrew 3701 E. Tudor Road, Ste. #101 Anchorage, AK 99507 Re: The Shier Lot 2 Dear Kyle: P.1 The lift station at the above referenced property has been wired In accordance with NEC and State/Local codes. Thank you. Sincerely, J [;�t.►cw�-sig. yvrr� Kevin S. HornbucIde, Owner Administrator Llcense Number 1284 Specialty Contractor License Number 27285 cc: file MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 995M6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Permit Number: SW070186 Date Issued: Aug 02, 2007 Expiration Date: Aug 01, 2008 Parcel ID: 051-293-55 Legal Description: T1 5N Rt W SECTION 30 LOT 58A Design Engineer: 0855 GARNESS ENGINEERING GROUF Site Address: 19431 MONASTERY DRIVE Owner Name: DAN GRAY Lot Size: 115083 SO. FT. Owner Address: 18518 TALARIK DRIVE Total Bedrooms: 4 Permit Bedrooms: 4 EAGLE RIVER, AK 99577 - This permit is for the construction of: ❑✓ Disposal Field ❑? Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by catling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. THE UPPER 6" OF THE MOUND SYSTEM IS TO HAVE TOP SOIL AND BE VEGETATED SUFFICIENTLY TO . PREVENT EROSION. i Received By. �' / �%L/Z Date: ° Issued ByDate: Z O Municipality of Anchorage Development Services Department Building Safety Division."/' On -Site Water & Wastewater Program 4700 Bragaw Sl. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. i75 1 • a93-55 Property owner(s) _DAN GRAY Day phone 360-4603 Mailing address 18518 TALARIK DRIVE ' EAGLE RIVER, AK Site address A 14 �9 fflt)oa-_-df_-V(4 M_ Zip Code 99577 cj Legal description (Sub'd, Block & Lot ) LOT 58A Legal description (Township, Section & Range) T15N. SECTION 30, R1 W Lot Size 1151 D$'3 Sq. Ft. Number of Bedrooms 4 hl,LAr THIS APPLICATION IS FOR ( ®all that apply): Absorption Field 9 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well Water Storage ❑ THIS APPLICATION IS AN: Initial 9 Upgrade ❑ Renewal ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. Permit/Rush Fees: �/('d i J 1 C1l Date of Payment::ZLit, 'lo -7 Receipt Number: H -70 (Rev. 11/05) Waiver Fees: Date of Payment: Receipt Number: GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS. July 25, 2007 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907)343-7904 Ref: Proposed Well for T15N, R1W, Section 30; Lot 58A To whom it may concern: The proposed 4 bedroom house is to be served by a private well and septic system. A exploratory well was permitted and drilled on the property. Attached is a site plan and design drawing showing the new well location. The property owner has plans to add a 3 bedroom addition in the future and convert the building into a duplex. This would bring the total house size to a total of 7 bedrooms. Per the request of the owner, we have sized the septic system to accommodate this proposed addition. It will the responsibility of the property owner to obtain approval of all required agencies at the time of the addition. We are proposing that a 2500 gallon septic tank, a Quanics Aerocell Treatment system, which includes a 36 inch pump vault, two 650 Aerocell units and Jandy valve basin; and bed type drainfield be installed. A total of three test holes have been excavated on the property. The drainfield will be designed around the 30 foot radius of test hole #2. It is our understanding that the property is proposing to subdivided the property also in the future. Comments regarding the design are summarized as follows: 1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring, and the percolation test results. It is our opinion that an application rate of 3.0 gallons/day/112 should be used. 2. BED DESIGN: See attached design drawing for drainfield specifications 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system. 4. TOPOGRAPHY: The area for the proposed septic system is generally flat. In short, there are no slope concerns. 3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507-1259 Ph: (907) 337-6179 • Fax: (907) 338-3246 • Website: www.gamesscnginecring.com We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. Sincerely, P.E., M.S. NOTE. A site plan drawing, a design drawing, two detail drawings, three soil logs, and a 7 page construction specification letter which are all part of the design package for this septic system. 3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507-1259 Ph: (907) 337-6179 • Fax: (907) 338-3246' Website: www.gamcmngincering.com i--4 I I I I i I I I I I I I I I I I I 1 oil IT! 3 � / f 1A�«YIP 2 b�1111 jig b W b FF R i ! ZP 4 r r 1 7/24/2007 J.L.M. LEGAL DESCRIPTION: T15N, RiW, SECTIN 30, BLM LOT 58A TYPE OF WORK: DESIGN OF QUANICS AEROCELL SYSTEM PkLPARED FOR: PHO DANIEL GRAY I 3 0 r m z 0 ly a m 0 a Z s F R? 4 v '•J. A. GGrn ss.: GARNLSS ENGINEERING GROUP, Ltd. �0 E e, CONSULTANTS 6 GENERAL CONTFACrOFs�.+.�.�+ o� '• .y'• �8L . c ,m c e. wnc «.. noo.z .� wm wo.c 1<n Wn ,nfl n Mn a« n« . wwm .-.. w�. 04 4e 2s O' F.cQo 0 PA0 3 OF 4 E: O pro re sslo^Oo ��Opppo�� yy 4 M i L oil IT! 3 � / f 1A�«YIP 2 b�1111 jig b W b FF R i ! ZP 4 r r 1 7/24/2007 J.L.M. LEGAL DESCRIPTION: T15N, RiW, SECTIN 30, BLM LOT 58A TYPE OF WORK: DESIGN OF QUANICS AEROCELL SYSTEM PkLPARED FOR: PHO DANIEL GRAY I 3 0 r m z 0 ly a m 0 a Z s F R? 4 v '•J. A. GGrn ss.: GARNLSS ENGINEERING GROUP, Ltd. �0 E e, CONSULTANTS 6 GENERAL CONTFACrOFs�.+.�.�+ o� '• .y'• �8L . c ,m c e. wnc «.. noo.z .� wm wo.c 1<n Wn ,nfl n Mn a« n« . wwm .-.. w�. 04 4e 2s O' F.cQo 0 PA0 3 OF 4 E: O pro re sslo^Oo ��Opppo�� NUMBER OF BEDROOMS: 4 (•7) LETTER OTHATI A( GALLONS PER DAY (CPD): 600 (•1050) CONTACT CEC. I PERCOLATION RATE/S: 5 MIN./INCH WITH THIS INST. PROPOSED APPLICATION RATE: 3.0 WELL DRILU _ MINIMUM DRAINFlELD SO.FF.: 200 (•350) PROPERTY ON -SYSTEM SIZED OR POSSIBLE ADDITION HAVE READ THI AGREE TO A( DRAINFIELD DESIGN: \ MAXIMUM DEPTH: 3 FEET / \ WIDTH: 15 FEET LENGTH: 30 FEET M.O.A. APPROVED SAND FILTER: 2.0 EFFECTIVE: 1 FOOT ACTUAL SOFT.: 450 / \ \ PROPOSED 36 INCH PUMP VAULT \ \ WITH OUANICS PUMP AND FL / \OPOSED CS00 GALLON \ /l�(EV INCHES OF RICID I BY EEO WIDE ON PIPE OVER ALL UNDER DRIVEWAY. 1 • •• • : •• •r' •j• 1 T .±'� �i•' 1 -INSTALL FOUNDATION i o .; ..: �.�"•'':i �•.t .,.: i. CLEANOUT i DESIGN. LETTER POSSIBLE NEW PROPERTY LINES WITH FILING OF PRELIMINARY PLAT f— TERNATE SITE E� I I 0H 2 J — _ MT AREA FOR �ROPOSED PROPOSED 4 BEDROOM PROPOSED PROPOSEDr DRAINFlELO DUPLEX HOUSE GARAGE 1 ADDITION 11 TWO (2) 650 CPD OUANICS A IN 1 �� UNITS WITH DANDY VAI' -NEW WELL 20 UBLIC USEEASEMENT / 15' UTILITY EASEMENT MONASTERY DRIVE _ / GARNESS ENGINEERING GROUP, Ltd. 11re . 4 CONSULTANTS & GENERAL CONTRACTORS Q• 3A1 L 110011 0010. WR 101PREPARED FOR: PHONE NUMBER: PAGE NUMBER: .•• ••......DANIEL GRAY 360-4603 2 OF 4 p• D ';�ness. T15N, R1W, SECTION 30, BLM LOT 58A J.L.M. 'UOf, VV'•.TI"' OF WORK: DATE: 44�Opo0 DESIGN OF PROPOSED SEPTIC SYSTEM 7/24/2007 (Rev. 01)05) 1 4' MONITORING TUBE r — — — — — — — — — — — — — — — — — — - — — —�' 4' MONITORING La------ ---------------- -26 FEET LONG LATERALS 30 FEET LONG 4' CLEANOUT `ANAL GRADE /�-4 CLEANOUT /ry CLEANOUT 4' MONITORING TUBE' \ / / �--4' MONITORING TUBE NOTE: MOUND UI HAVE TOPSOIL AND SEEDED FABRIC ^+h ,v..'\ �' +� ivy,,: �`�"`'` •4"•*i.4�4� `?�`.:y�:::• 3 FEET OE P MAXIMUM f OF EFFECTNE� �.<.a+rz�y�Gj W ii iw.i n yip's. �L�IV 2 FEET OF M.OA J APPROVED SAND FILTER --15 FEET MADE GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS sm L AOM bio. be[ to, • /UOe•eL ee eH01 • e.a.[ op)lU)-4.r • fN (W�S.Y-.))4 • ISR: w f.�••ry�••rtis• PREPARED FOR: PHONE NUMBER: PACE NUMBER: DANIEL GRAY 360-4603 4 OF 4 LEGAL DESCRIPTION: DRAWN BY: T15N. RiW. SECTION 30. BLM LOT 58A I J.L.M. TYPE OF WORK: DETAIL OF PROPOSED DRAINFIELD (Rev. olms) 7, WIDE =::..x:fil.r. �r•.......... ...... fIESS' _ooaooppp0 20 GARNESS ENGINEERING GROUP, Ltd. ? 0 QO �•�.•r�—� CONSULTANTS & GENERAL CONTRACTORS i 4 ' T 6 Ml L 360gi WN), 61MR 161 • NCHDR G_ W. 90W7 n,a•[: W) 7—Uri • 7M: (W74346 • •CBS�IC por,ww4rgiwr0p.cgn �• • • • • • . • • • • • • • • • • • • • .D SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: T15N, R1W, SECTION 30, BLM LOTS 56A & LOT 133, P fey or ss: a PERFORMED FOR: DANIEL CRAY DATE: / 5 2007 r� •'•., Zb•' �Fo0� DEPTH ---- olesslo^°oma (feet) ____ ORGANICS TEST HOLE#21���p000�o SOIL CLASSIFICATIONS I ORG 3 `GP ML GM CL q GC OL y GM—SM oe goo o SW MH �N : SP CH 5 SM . ; off SEE ATTACHED 6 SC SITE PLAN 7 8 DEPTH TO BEDROCK B.O.H. 9 DRY 5/7/2007 s® 3' .300' 10 11 DATE READING CLOCK NET TIME WATER LEVEL NET DROP 12 13 14 15 16 17 18 19 PERCOLATION RATE 5 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 2.0 FT. AND 2.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: ® YES ❑ NO SOILS LOGGED BY: CALEB GALL PERCOLATION TEST PERFORMED BY: CALEB GALL COMMENTS: PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: L6 lcq GROUNDWATER DATE DRY 1/5/2007 DRY 1/12/2007 1 8/2007 1 2:45 — TIME (MINUTES) READING (INCHES) 1 8/2007 1 2:45 — 6" — 2 3:15 30 0" 6" 3 3:15 — 6" — 4 3:45 30 0" 6" 5 3:45 — 6" — 6 4:15 30 0" 6" GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS --��• SOIL LOG — PERCOLATION TEST LEGAL DESCRIPTION: T15N. R1W, SECTION 30, BLM LOT 58A k PERFORMED FOR: DANIEL CRAY DEPTH (feet) TEST HOLE 1 1 ORGANICS 2 3 4 5 GW -SW 6-IlMltitTi GM -SM 7 8 9 10 11 12 13 14 15 16 17 18 OIL CLASSIFICATIONS DEPTH TO GROUNDWATER DATE 5.0' 1/5/2007 1111m, 1/12/2007 34' 5/7/2007 2 0o. 0' HNH lzr • - - 6- 01 VON, - 7 1� •i 6- Y/i i • 6- 6 - 7 DEPTH TO GROUNDWATER DATE 5.0' 1/5/2007 DRY TO 4.5' 1/12/2007 34' 5/7/2007 2 - 7 Q A SEE ATTACHED SITE PLAN DATE READING CLOCK NET TIME TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 1/8/2007 1 - - 6" - 2 - 7 0' 6' 3 - - 6- 4 - 7 0' 6- 5 - - 6- 6 - 7 0' 6- 19� PERCOLATION RATE 1.17 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 2.0 FT. AND 2.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES ® NO SOILS LOGGED BY: CALEB CALL PERCOLATION TEST PERFORMED BY: CALEB CALL COMMENTS: N�,7 54ir�c.4Lr= %rLyim,S,qc- CepT-iL PERFORMED BY GEC, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WA PER ORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: Z f. ��c•• �F•. ' '95;00 GAR1`ESS ENGINEERING GROUP, Ltd. 74 ���•�� CONSULTANTS & GENERAL CONTRACTORS tr oO 3701 L •won uao. SUFE 161 • NCHDRAGr, 6«. 6uw7 • P L (W)MI-Gin • fu: W7 -3246 • wr L ,...�wq.rvq.o•iw ) 4 4 4 4.. .. • • • • • • • • • •. SOIL LOG — PERCOLATION TEST ••• LEGAL DESCRIPTION: T15N. R1W, SECTION 30, BLM LOT 56A k LOT 133 P (r Y A. arnessr Q PERFORMED FOR: DANIEL GRAY DATE: 23 200 ° CE -7953 :p 5 ec iv..Z6�or%�oo (feet) __-- ORGANICS ����0000�1% TEST HOLE 3 SOIL CLASSIFICATIONS 2 b`y =__ .ra.. GW = ORG T �4aE warans 3 �:a* is GP ML ` AkE APMXI"TE GM CL 4 SM 6, 6 GC OL 7H#3 e•66 SW MH 5 • SP Chi SM OH t 6 SC i � / q 7 BEDROCK / _ B TH#2+ .' �v sr O v 9 SCALE: 10 11 12 13 14 15 16- 17 18 19 PERCOLATION RATE 5 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 2.0 FT. AND 3.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑ NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: BENNY MAUS COMMENTS: RECOMMEND USING A 0.6 APPLICATION RATE PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: b/26/0q DEPTH TO GROUNDWATER DATE DRY 5/23/2007 DRY 5/30/2007 5/25/2007 1 4:00 - DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 5/25/2007 1 4:00 - 6' - 2 4:30 30 0" 6" 3 4:30 - 6" - 4 5:00 30 0" 6" 5 5:00 - 6" - 6 5:30 30 0" 6' MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WATER SUPPLY PERMIT Initial Date Issued: Feb 16, 2007 Expiration Date: Feb 16, 2008 Permit Number: SW070011 Parcel ID: 051-293-55 Legal Description: T1 5N R1 W SECTION 30 LOT 58A Design Engineer: 0855 GARNESS ENGINEERING GROUF Site Address: 19431 MONASTERY DRIVE Owner Name: DAN GRAY Lot Size: 115083 SO. FT. Owner Address: 18518 TALARIK DRIVE Total Bedrooms: 0 Permit Bedrooms: 0 EAGLE RIVER. AK 99577 - This permit is for the construction of: ❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specked in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. ANOTHER PERMIT MUST BE OBTAINED TO DRILL ANY ADDITIONAL WELLS ON THIS PROPERTY. WHEN THE WELL HAS BEEN COMPLETED AND SATISFACTORY WATER PRODUCTION HAS BEEN DETERMINED, THE WELL DRILLER SHALL PLACE AN APPROVED SANITARY SEAL ON THE WELL HEAD AND NO PITLESS ADAPTER OR PUMP SHALL BE INSTALLED UNTIL AN APPROVED WASTEWATER DISPOSAL SYSTEM HAS BEEN CONSTRUCTED. I Received By: RariAMn,917r�� Date: Date: Z / O Municipality of Anchorage Development Services Department •xl.��� lcrh- Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON—SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 05t- c) -q:5-55 Property owner(s) DAN GRAY Day phone 360-4603 Mailing address 18518 TALARIK DRIVE • EAGLE RIVER. AK Site address (q Ll 3 ( m D Yl ) ST E2:�4 Oy% Zip Code 99577 Legal description (Sub'd, Block & Lot) LOT 58A Legal description (Township, Section & Range) T15N. SECTION 30, R1 W Lot Size list 0$ 3 Sq.Ft. Number of Bedrooms N/A THIS APPLICATION IS FOR( ®all that apply): Absorption Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well LP.L, Water Storage ❑ THIS APPLICATION IS AN: Initial Upgrade ❑ Renewal ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. Permit/Rush Fees: lU 17 5L d0 Date of Payment: 1 — 5 _ L -7 Receipt Number: - 5 7.6 (Rev. 11/05) Waiver Fees: Date of Payment: Receipt Number: GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS rr=—����—® February 13, 2007 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907)343-7904 Ref: Proposed Well for T15N, R1 W, Section 30; Lot 58A To whom it may concern: The referenced property is currently undeveloped and the owner is interested in subdividing it. Two test holes were excavated on the property and soils suitable to support on-site septic systems were encountered. Seasonal high groundwater monitoring will need to be done on May 15, 2007. Attached is the soils report. The owner would like to drill a exploratory well on the property to confirm there is an adequate water supply. Attached is a site plan which shows two possible well locations. This area is known for low producing wells and "dry" wells so we have provided two well sites. It will be the responsibility of the well driller to inform your department if the second well site is to be drilled. The well driller will be Sullivan Water Wells and it is our understanding that Mr. Sullivan has faxed a letter to your department (attention: Jeff Poet), giving justification for the exploratory well/s. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. A Sincerely, P.E., M.S. 3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507-1259 Ph: (907) 337-6179' Fax: (907) 338-3246 4 Website: www.gamessenginecring.com ir. I / I 150' WELL RADIUS / -I I / L: DRAWN BY: ... 2/13/2007 J.L.M. AL DESCRIPTION: T15N, RiW, SECTION 30, BLM LOT 58A GARNESS ENGINEERING GROUP, Ltd. 'E OF WORN: CCNSULTANIS d GENERAL CONTFACTOFS SITE PLAN PARED FOR: PHONE NUMBER: PAGE DANIEL GRAY 360-4603 1 OF 1 / H N z f N z u 0 0 N ffwiw uw Je .... V fj It y tCnc�ess: V v —795310 ' .........• . e°''c 0 m I / \ / 1 I I I I \ I I\ I \. I / I 150' WELL RADIUS / -I I / L: DRAWN BY: ... 2/13/2007 J.L.M. AL DESCRIPTION: T15N, RiW, SECTION 30, BLM LOT 58A GARNESS ENGINEERING GROUP, Ltd. 'E OF WORN: CCNSULTANIS d GENERAL CONTFACTOFS SITE PLAN PARED FOR: PHONE NUMBER: PAGE DANIEL GRAY 360-4603 1 OF 1 / H N z f N z u 0 0 N ffwiw uw Je .... V fj It y tCnc�ess: V v —795310 ' .........• . e°''c Municipality of Anchorage onsite water and wastewater Program Anchorage, AK Sullivan water wells P.O. Box 670272 Chugiak, AK 99567 Pebtuary 7,2007 To whom it may concern This letter is in regards to a request for an exploratory aster well drilling peratit for T15N R1P1 Section 30 Lot 58A. This lot is located on Manastery Drive in Chugiak. The well is to be drilled for Daniel Gray, 18518 Talarik Drive, Eagle River, Alaska. it is my considered opinion, as it well driller in the arca for over 30 years, with as cdcasive history of wells drilled in the aforementioned arca, that obtaining water for this lot may not be possible. The public records, as well as nay own, will show that wells within a half mile radius of this lot are very deep and usually dry. I hope you will take these Wars into account and grant an cVlomtoty permit for this lot. Sincerely, Charles W. (Bill) Sallivan T8/To 30vd MIHl1I-rM 69ZZ889 4h:TT LooZ/Lo/Zo MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION Environmental Health Division CASE REVIEW WORKSHEET CASE NUMBER: S-8572 DATE RECEIVED: I November 5, 1986 COMMENTS DUE BY: December 1, 1986 SUBDIVISION OR PROJECT TITLE: T15N R1W Section 30 Lot ��{{ 58 ( ) PUBLIC WATER AVAILABLE ( ) COMMUNITY WATER AVAILABLE ( ) PUBLIC SEWER AVAILABLE COMMENTS: (/G its I2/Z J f % 71-014 (Rev. 5/89) PRELIMINARY PLAT APPLICATION OFFICE USE h¢-- Municipality of Anchorage �. DEPARTMENT OF COMMUNITY PLANNING dd P.O. Box 6650 VERIFY OV N Anchorage, Alaska 99502-0650 A. Pleas- hu In !�- -formation requested below. Print one letter or number per block. Do not write in the shaded blocks. 0 Case Number (IF KNOWN) 1. Vacation Code IEl 2. New abbrev*:ed legal description (T12N R2W SEC 2 LOT 45 OR SHORT SUB B1K 3 LOTS 34). rm c• -r ..- T 1 1 N. 1 1. JSEC 3 10 1. IL IT 15 3. w - c� Existing attrevtated legal description (T12N R2W SEC 2 LOT 45 OR SHORT SUB BLK 3 LOT 34) full legal on back pace. a Fc . r 's %,r?e (Las; - Firs /% ! �A 4D 701_;IJ Address e^�8 .. * rarel.,,a r City — -AnehoStale rage St Ataska- --___-- " Address W^ �4D C, 5. Petitioner's Representative 401 East Fireweed Lane City Anchorage State Alaska Phone Ns —276 3770 — BillMe -N17—Phone No. 276-3770 Bill Me NO Representing M.O.A. - Property Management - Contact, Roy Dudley or Charlie O'Neall 6 Pat,', -- area 7. Proposed 8. Existing 9. Traffic 10. Grid Number 11. Zone Acrear+ Number Number Analysis Zone Lots fLoltss I 2 I, ig 13 i _i � L_1J..: 5 9 N W 7 5 5 R - 7 S L 12. Fee ; MUNI - 0409-7285-M45R76 13. Community Council CHUGACH B. I hereby ce: t,'y tl at if am) (I have been authorized to act for) the owner of the property described above and that I desire to subc.v!oe I! In conformance with Chapter 21 of the Anchorage Municipal Code of Ordinances. l understand that payment of the tzs;c sutcl�:slon fee is nonrefundable and is to cover the costs associated with processing this application, that It does no; assure approval of the subdivision. I also understand that additional fees may be assessed if the Municipality s costs to pieces-, !h,s application exceed the basic tee. I further understand that assigned hearing dates are tentative and may be have!o Ccst; oned by Planning Staff, Platting Board, Planning Commission, or the Assembly due to administrative reascr-. Date: �� Z�� �1�.>'. lc•Ccs—� Signature $ 8 5 ? 2 DEC 17 1986 'Agents must provide written proof or authorization. A-Kj Floe: I: 1- C. Please check or till in the following: 1. Comprehensive Plan — Land Use Classification Residential Marginal Land Commercial Parks/Open Space Transportation Related 2. Comprehensive Plan — Land Use Intensity Commercial/Industrial Alpine;Slope Affected Industrial Public Lands/Institutions Special Study Dwelling Units per Acre Special Study Alpine/Slope Affected 3. Environmental Factors (if any): N/A a. Wetland b. Avalanche 1. Developable c. Floodplain 2. Conservation 3. Preservation d. Seismic Zone (Harding/Lawson) D. Please indicate below it any of these events have occurred in the last three years on the property. Rezoning Case Number Subdivision Case Number Conditional Use Case Number Zoning Variance Case Number Enforcement Acton For Building/Land Use Permit For _ Army Corp of Engineers Permit E. Legal description for advertising ctioL.M. Alaska n T.15 N. R.1 W. Seward Meridian, F. Checklist 30 Copies of Plat Reduced Copy of Plat (8'. x 11) Certificate to Plat C Fee Topo Map 3 Copies Soils Report 4 Copies t Aerial Photo Housing Stock Map Zoning Map Water: Sewer: l w, ba«001 Waiver 0409-7285-M45R76 Community �privateWens-�'�� Y Well Public Utility Private Septic Community Sys. Public Utility APPLICATION FOR VACATION OF PUBLIC R.O.W. OR EASEMENT SUBMIT TO: Municipality of Anchorage (*D7, Department of Community Planning 632 W. 6th Avenue • Anchorage, Alaska 99502-0650 Phone: 264-4267 REOUEST: Theunderslgned hereby applies to the Municipality of Anchorage for approval of lnpvdcaDon of the following (give complete legal description) and as shown on the attached sketch. SUBDIVISION NAME B.L.M. LOT 56 Located In the N.E. QUARTER (allouot part) of Section 30 . Township 1 N. Range 1 N' . S M . Alaska Are utility lines or service easements within the vacation request area? YESU NO (If yes, these must be shown On the accompanying map I CERTIFICATION: I (we) hereby certify that I (we) are the owners of the majority of the front feet of the land fronting the part of the public nghl-of-way or easement described above and I (we) request approval Of this vacation. 1 (We) understand that the fees paid as part of this application are to cover processing expenses and do not assure approval of our request. IDESIGNATE PRIMARY APPLICANT (MAIN PERSOtjjTO CONTACT) BY ASTERISK(. KENNETH LEE HORTON / ELM LOT 58 Ovine', name IV..,) fi �,'.Iural ... _.1a ,� Progeny ornea P.O. Rnx 337. sOUTH BENn N Aaw", Im4I•n2I NA. 98586 Pnon1 N..W' Owner s nlme Igrmq AddFess lmxmrpl s no" Iprmq ISgaturel Peon! Numew Is'gnelme) P,oMny owrlea Progeny *v,vHJ ImMi•ng1 Pito. NurnOer Progeny Own NOTE: All persons applying for this vacation should be aware of the fact that one Of the conditions for approval of the vacation is the filing of a suitable replat within an eighteen (18) month period. A suitable replat can be interpreted as meeting all the conditions specified in the Land Subdivision Regulations This includes. but Is not limited to. entering into Subdivision Agreements for paving of streets, providing underground utilities. sewer and water, etc. Additionally all parties affected by this vacation will have to sign the replat. as well as any Subdivision Agreement. It should be noted that the survey or engineering expense Is borne by the property owners and a guarantee of an acceptable replat Is not granted merely because the subject property is vacated. Staff asks you to weigh these facts and conditions and review the Subdivision Regulations carefully prior to submitting this vacation request I have read the above statement and recognize that a suitable replat is subject to approval of the Platting Board and conformance with the Land Subdivision Regulations. Signed DO NOT WRITE BELOW THIS LINE SUPPORTING (required at time of submittal) DATA: ��..pp Statement of Justification Received by ' (Date) ' ` '-(30 copies of map Received by (Date) \\�' 'Fee. 0409-7 85-M45R76 Received by (Date) 'aas•cFw AOOn.onlrgnlrgymrybNvIad MunK•p1lLOSIf LgMOIMDIPC In AOOA•MIKnMp<s w11W D•nM M019 In- IMI S 8 572 DEC 171986 JUSTIFICATION: The Anchorage Municipal Code requires the petit oner to provide the burden of proof that the area to be vacated has no value to the Municipality Please provide your justification for the vacation below or on a separate sheet. (AMC 21.15 130) THEjA$EMENT ON THE NORTHERLY BOUNDARY OF BLM LOT SE _j5_BLMQ VACAUj) TO AL_LQW THE_GREAJLON OF AN EASEMENT _—oN THESQuIHERLY BQMARY.-IQ—RQADwAY—J�1LL-EYE BE_ _CDIiMIICM__ALo MG_IKLAQRIHERLY_.BQIINDA&Y_WH R AS A_ RMWAY [NRRENTLY EXISTS ALONGSHE—SOUTHERLY DSLDARY. _,HE M NICIPALITY R ECEN_TLY [ORSTRUCTED THE RQADWAY ALOZ(f THE c_QIITHERLY 80UNDARY_AND. IS QyWJERLATTING LM14L1` B�Q—THE—R=YLAY-1AY_BES411IAIKED--KLIHI N_AN MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION Environmental Health Division CASE REVIEW WORKSHEET CASE NUMBER: S -8572A DATE RECEIVED: March 25, 1987 COMMENTS DUE BY: April 20, 1987 SUBDIVISION OR PROJECT TITLE: T15N R1W Section 30 Lot 58A - Condition of Approval Modification ( ) PUBLIC WATER AVAILABLE ( ) COMMUNITY WATER AVAILABLE ( ) PUBLIC SEWER AVAILABLE COMMENTS: 71-010 (Rev. &W) 1057 WEST FIREWEED LANE. SUITE 230 ANCHORAGE. ALASKA 995034736 (907) 276-3770 DATAFAX NO. (907) 279-5092 ANCHORAGE e JUNEAU BETHEL March 23, 1987 Municipality of Anchorage Department of Community Planning 632 West 6th Avenue Anchorage, Alaska 99502 s-3-s'7a,- . .f ME EL .n V. Attention: Jerry Weaver Subject: 5-8572, BLM Lot 58A - Regarding Condition Modification Application Dear Mr. Weaver: Roy Dudley of the Municipality of Anchorage, Department of Property and Facility Management has asked me to write this letter to aid in the completion of S-8572. Mr. Horton, the owner of Lot 58A, has refused to sign the re -plat with the note prohibiting direct vehicular access to the Old Glenn Highway. Mr. Dudley has been in contact with the Alaska DOT/PF and has developed terminology for the note which is acceptable to the State and to Mr. Horton. The revised note is shown on the accompanying attachment. This note would replace comment No. 2 as recommended by the Platting Board on December 17, 1986. Should this plat need to be re -submitted to the Planning Board, please accept this letter as an application for the same. If you have any questions, please contact me at 276-3770. Sincerely, Daniel A. Wohl, R.L.S. Survey Manager DAW/jb S- 85VA M04 &I M97 SUMMARY OF ACTION Platting Board Meeting December 17, 1986 Page 4 The vacation on the west boundary of BLM Lot 24 was denied. The plat was approved subject to: 1. Resolving utility easements. 2. Resolving drainage and drainage easements with Public Works Engineering. 3. Providing a permanent turnaround, type to be resolved with Public Works Engineering. 4. Resolving the location of the sewer system and the well with DHHS. 8. S-8572 BLM LOT 58A The vacation was approved subject to filing a suitable replat within 18 months. The plat was approved subject to: 1. Resolving utility easements. 2. Placing a note on the plat prohibiting direct vehicular access to the Old Glenn Highway. 3. Providing a 10' vegetative easement exclusive of utility easements along the east boundary of Lot 58As landscaping plan to be approved by Community Planning with a bond for its installation. 4. Showing a 30' dedication on the southern boun- dary for Monastery Drive. 5. Showing Cremin's Drive as Monastery Drive on the final plat. 9. S-8576 ORDINANCE AMENDMENT 21.15.125 The ordinance amendment was approved which will allow the Platting Officer rather than the Platting Board to take action on maintenance easement vaca- tions in zero lot line developments. Zoo • f O 1 " i Z• i A 41 1 r r III ► t, �„ �'�,, , �, co e N 1 C=) 1, � I I• a I �n 0 . � 6�1iy 7U j Municipality of Anchorage On -Site Water & Wastewater Program "� < (907) 343-7904 4C� a E RO � 8 9 � CERTIFICATE OF ON-SITESYST MS APP V Parcel I.D. 051-293-72 1. GENERAL INFORMATION Complete legal description Location (site address) Expiration Date: a-gY2'0Z0 THE SHIRE S/D: LOT 2 - THE SHIRE CONDOMINIUM A 19401 MONASTERY DRIVE, EAGLE RIVER, AK 99577 Current Property owner(s) DANIEL GRAY Day phone Mailing address Real Estate Agent 6000 E SHORE DRIVE, PENSACOLA, FL 32505 BARBARA CRITTENDEN 2. TYPE OF DWELLING: ❑ Single Family (w/wo ADU) IN Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 4. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System Day phone 360-4603 689-1802 WaiverNariance request for. N/A Distance: - Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ �5�� Waiver Fee $ Date of Payment % q �� pr—, Date of Payment Receipt Number 0 �� (A Receipt Number COSA #-�� ` �� s Waiver # TYPE OF WASTEWATER DISPOSAL: IN Individual On-site ❑ Individual Holding tank ❑ ❑ Community On-site ❑ ❑ Public Sewer ❑ WaiverNariance request for. N/A Distance: - Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ �5�� Waiver Fee $ Date of Payment % q �� pr—, Date of Payment Receipt Number 0 �� (A Receipt Number COSA #-�� ` �� s Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Address GARNESS ENGINEERING GROUP, Ltd. 3701 E. TUDOR ROAD, SUITE 101 " ANCHORAGE, AK, 99507 Engineer's Printed Name Engineer's Comments: JEFFREY A. GARNESS, P.E. In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the systems on the date/s of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or encroachments may exist that were not identified during the evaluation. The operational life of all wells and septic systems depend on a variety of variables including, but not limited to, soil conditions, groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the systems. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not guarantee future performance of the systems; therefore, GEG makes no warranty (express or implied) regarding the future performance of the well or septic system. GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the current systems fail. The content of this report is for the sole benefit of the persoruparty who retained GEG. Reliance upon the information provided in this report by any other person or party, including but not limited to subsequent property purchasers, is not authorized. In short, GEG disavows any legal duty to anyone other than the person/party who paid for this report. 6. DSD SIGNATURE System #1 Approved for bedrooms. Phone 337-6179 Date )Q ) Z i3 #AtL;LA3tS4 System #2 Approved for bedrooms. �e�,,l�lt((tll(f(ffPr Disapproved. P ��`! OF Conditional approval for bedrooms, with the followinlaticz3_SI,N �, r JJ/ Original Certificate Date: " The Municipality or Anchorage Develop,emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist _ Septic System Advisory Well Flow Advisory (Rev. 10/12/12) Nitrate Advisory Arsenic Advisory Other COSA Checklist Legal Description: THE SHIRE S/D; LOT 2 - THE SHIRE CONDOMINIMUMS A parcel ID: 051-293-72 If more than 1 septic system on lot: COSA Checklist # 1 of 1 Structure served by this system 1 A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 2/27/07 Total depth 300 ft Cased to 44 ft (BEDROCK @ 16) ❑ Sanitary seal is functioning correctly Al Wires are properly protected Casing height (above ground) 18+ in. Date of flow test for COSA 10/1/19 Static water level at beginning of test 20.1 ft. Comments B. TANK DATA Age of tank(s) 12 years Tank type/material STEEL Measured operating fluid level in septic tank ❑ Standpipes/foundation cleanout per record drawing Date of pumping SEE ARM SEPTIC SERVICE MAINTENACE REPORT D. ABSORPTION FIELD DATA BED Which system tested (date installed) 1114 '1710' ❑ ALL standpipes present per record drawing Total measured depth from grade 4.2 ft (max) Measured depth to pipe invert from grade 2.9 ft (min) ❑ N/A — pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective Well production at time of test 1.9 gpm Water storage tank volume NIA gallons Well disinfected for coliform test? . E] Yes ❑ No .Coliform bacteria is Negative Nitrate.,p g mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ;Arsenic less than MRL (ND) Collected by GEG, LTD. Date of Sample 10/1/19 C. LIFT STATION ❑ Required maintenance completed Age of lift station 12 years Lift station material STEEL Comments: 'LIQUID LEVELS NOT REQUIRED TO BE CHECKED PER TIM EKLUND. SEE ARM SEPTIC SERVICE MAINTENACE REPORT FOR DETAILS Adequacy test date F' 10/1/19 Results ❑✓ Pass For 6 bedrooms Fluid depth prior to test 0 in Water added 900 gal New depth 0 in Elapsed time 0 min 0 ❑ Code -required soil cover over field anal fluid depth in Absorption rate 900+ gpd F] System presoaked (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) N/A date of test) Gallons introduced NSA gallons If yes, enter date Comments/Deficiencies: COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' Yes 50+ Community Sewer Manhole/Cleanout > 100' Surface Water > 100' ❑ Yes if No ft ❑r Yes if No ft Neighboring Tank > 100' [Z Yes if No ft Private Sewer/Septic Line > 25' ❑r Yes if No ft Absorption Field on Lot > 100' ❑ Yes if No 50+ ft Holding Tank > 100' ❑✓ Yes if No ft Neighboring Absorption Fields > 100' Water Service Line > 10' Yes Animal Containment > 50' ✓❑ Yes if No ft 0 Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' 0 Yes if No ft ❑✓ Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' Yes if No ft Surface Water > 100' ❑✓ Yes if No ft Property Line > 5' Q Yes if No ft Wells on Adjacent Lots: Wells on Adjacent Lots: Absorption Field > 5' Yes if No ft Private Wells > 100' ❑ Yes if No 50+ ft Water Main > 10'✓❑ Yes if No ft Community Wells > 200' ✓❑ Yes if No ft Water Service Line > 10' Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ❑ Yes if No ft If absorption field is under driveway comment below Property Line > 10' 0 Yes if No ft Wells on Adjacent Lots: Water Main > 10'✓❑ Yes if No ft Private Wells > 100' ❑ Yes if No 50+ ft Water Service Line > 10' ❑r Yes if No ft Community Wells > 200' Yes if No ft Surface Water > 100' ✓❑ Yes if No ft F. ENGINEER'S COMMENTS WATER SOFTNER IN HOUSE. BACKWASH FLOWS INTO SEPTIC SYSTEM. DISCHARGE OF THIS BACKWASH MAY EFFECT THE PERFROMANCE OF THE AEROCELL FOAM MEDIA. RECOMMEND OWNERS CONSULT ARM SEPTIC SERVICES (CERTIFIED SERVICE PROVIDOR) ON THE LONG TERM EFFECTS OF THIS ON THE MEDIA. G. ENGINEER'S CERTIFICATION OF q VU�p� I cert" that I have determined through field inspections and review D � 95�� �Y g p .r�Q : - of Municipal records that the above systems are in conformance with op* �* MOA COSA guidelines in effect on this date. �....:.... / •.Je- (k-795� me _ O / COSA Checklist yellow sheetf �oess�on a #AECC884 MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this lay ofof 20J 1 , by and between Z�VA A P- herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as located.at (legal description) 2. Maintenance,, Repairs and Alterations. (Owner is required to read, understand and initial each section) Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. J,A It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). Owner agrees that only maintenance and repairpersonnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page 1 of 3 3 Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 OWNER: (signature) Dater a1y ar)r 7 1�✓� �2 ✓� dS,J�-� _(Print name) STATE OF ALASKA ) ss. THIRD JUDICIAL DISTRICT } The foregoing instrument was acknowledged before me this day of 1-2( 20j3 by u4 ,Nj, &Qtl OFMKLNOTARY PUBLIC FOR ALASKA , Ma. �r M Commission ex ices: � .`> ' NOfaryPuUc g9100fAWb y p' �� 'V ^-mm. Expires MMCIPALI By: signature) (print name) (rev. 05/18/2018) Date: 1 Title: Page 3 of 3 ARM Services, LLC Maintenance Checklist: Advanced Treatment System Operational Checklist: Advanced Treatment System Legal Description: Street Address: [ct­tOVA En Intruln0 NOW"& V Service provided on: Date: `( Time: OL Service provided by: Company: > `� Employee. �+ t Date of last service: y �`°By: & � Other: 1. Type of Aerocell Treatmerft System: Cat 11- AeroCell Treatment System ❑ Cat IIIAeroCell Treatment System 2. Conditions at media filter: Acceptable ❑ Unacceptable a. Evaluate presZi f odor within 10 ft of perimeter of system: ❑ None ld ❑ Strong ❑ Chemical J Sour b. Source of odor, if present: 3. Manhole Risers and PipeC s: Acceptable ❑ Unacceptable a. Cover/s intact: Yes ❑ No b. Method of securing cover: c. Any plumbing leaks or water intrusion: ❑ Yes No d. Surface water/infiZableILI o components: ❑ Yes No 4. Venting/Air supply: �Uhceptable a. Air supply unit operating properly. Yes ❑ No b. Venting appears o erable. Yes ❑ No 5. Media surface: Acceptable ❑ Unacceptable B' t on surface ❑ esNo a. coma b. Uniform spray pattern. Yes ❑10 d. Ponding in/on media. ❑ Yes u N6 e. Plugging/clogging of nozzles.❑ es [! No f. Media appears to be settling. Vs ❑ No g. Appropriate maintenance performed. Yes XN h. Pest activity at surface. EllXYes 6. Effluent quality a. Effluent odor after passing through media filter: ne ❑ Mild Strong b. Effluent color after passing through media filter Clear ❑ Brown ❑ Black 24738 Chugiak Drive 'ChuC31k, AK 99567 Ph: (907) 317-9433 office/fax: (907) 688-9433 Email: ARMServicesAK@outtook.com PAGE 1 ARM Services, LLC 7, Tasks for recirculating/discharge flows: /Acceptable Unacceptable a. If applicable, Jandy valve functio ' g: ❑ Yes b. If applicable, Jandy Valve basin dry: Yes ❑ N c. Cleaned collection system in Aerocell unit: El No d. Design recirculation ratio: 80 e. Actual recirculatio ratio (Estimated): vv: 8. Pump System: Acceptable El Unacce�04ble a. Control panel in Auto: FJ Yes ❑ No b. Timer settings ON: Z11- KA n OFF: Override ON:Override OFF: 6A c. Floats in correct placement:Ye El No d. High water alarm operational: Yes ❑ No e. High water alarm count: dkm 'WA f. Pump run time: & M.i A g. Pump run counts: •A h. Effluent Filter serviced: L`t"Y i. Tank lids secured after inspection: I Y j. Weep hole functiona : es 9. Primary Tank: Acceptable ❑Unacceptable a. Sludge and scum level checked: /Ye b. Tank needs to be pumped: ❑ Yes c. Tank lids/caps secured after inspection: ❑ Yes d. Last Date Tank pumped: 10. Drainfield: ❑ No ❑ No ❑ No ❑ No N/A ❑ N/A ❑ Not Necessary EXTRAS: i - -Type of Monitoring System -Remote monitoring working?: 'e- S -Phone line working? Y:! N/A ❑ No Sludge/Scum levels: ❑ No ❑ No a. Type of Drainfield (circle one): 5 -wide Deep Trench b. Design Effective depth:- inches/feet c. Checked Liquid Levels in Drainfield: N ^^ Y s ❑ No MT#1 Liquid Level: Inches MT#2 Liquid Level: Inches MT#3 Liquid Level: Inches MT#4 Liquid Level:� Inches d. Is there any surfacing eifiuent: ❑Yes No 11. Is the system in satisfactory condition, and does it pass inspection?Yes ❑ NO Service Provider. 24738 Chugiak Drive 'Chugiak, AK 99567 Ph: (907) 317-9433 office/fax: (907) 688-9433 Email: ARMServicesAK@outlook.com PAGE 2 Municipality of Anchorage° •� Vy • "` Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 wnvw.muni.org/onsrg/onsAe /jam (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. O.5 /— ,2 9 3 `%2 COSA# 49 1. GENERAL INFORMATION Expiration Date: ��— 7- c 8 Complete legal description THE SHIRE, LOT 2 (PREVIOUS LEGAL: T15N, RIW, SECTION 30, LOT 58A) Location (site address) 19401 MONASTERY DRIVE " EAGLE RIVER. AK " 99577 Community Class Well Current Property owner(s) DANIEL GRAY Day phone 360-4603 Mailing address 18518 TALARIK DRIVE " EAGLE RIVER. AK " 99577 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing address Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site watersupply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and We of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage tiles and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Finn GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD. SUITE 101 • ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS. P.E. Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering anaWs of the system In accordance with ADEC and MOA DSD Guidelines 6 Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to reacRy Identifiable features. The operational life of ail wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is 'for- the orthe sole benefit of the owner fisted above. Any reliance upon or use of this report by any other person or party Is not authorized, nor will It confer any legal right whatsoever. 6. DSD SIGNA RE Approved for Disapproved. Conditional approval for Attachments: COSA Checklist Septic System Advisory Well Flow Advisory bedrooms. L. Date 6A7.k6 .y.m ....' .. . ............ o • Jef a Gaess; • 795301 eG .,Proresslo� bedrooms, with the ttlowing stipulations: Arsenic Advisory Maintenance Agreements Supplemental Engineers Reort Nitrate Advisory Other By: /Ar IIM\ Original Certificate Date: ON-SITE • WATER AND •; WASTEWATER PROGRAM Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water & Wastewater Program ' 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519.6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: THE SHIRE, LOT 2 Parcel ID: Q 5�Zw2 q 3- 702. A. WELL DATA (PREVIOUS LEGAL: T15N, R1W, SECTION 30, LOT 58A) Well type MATE If A. B, or C provide PWSID# N/A Well Log (YIN) YES Date completed 2/27/2007 Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES Total depth 300 ft. Cased to 44' (BEDROCK 0 15') Casing height (above ground) 18+ in. FROM WELL LOG AT INSPECTION Date of test 2/27/2007 Static water level 30 ft. �ft. Well production 2.5 —9 -P.M. N 9 -P.M. WATER SAMPLE RESULTS: Coliform colonies/100 ml. Nitrate ND mg./L. Other bacteria _46—colonies/1 00 ml. Arsenic: ' NO ug./L. Date of sample: 7/23/2008 Collected by: GEG Ltd. B. SEPTIC/HOLDING TANK DATA QUAINCIS SYSTEM Tank Type/Material S.T.E.P./STEEL Date'installed 11/14-17/2007 Tank size 2500 gal. Number of Compartments 2 Cleanouts (YIN) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) YES Date of pumping NEW Pumper – C. ABSORPTION FIELD DATA Be ow EXISTING GRAo Date installed 11/14-17/2007 Soil rating .p.d. 'or fe/bdrm) 3_0 System type BED Length 32 ft. Width 15 ft. Gravel below pipe 1.1 ft. Total depth •3.3-4.6 ft. Eff. absorption area"480 ft' Monitoring tube YES Depression over field NO n Date of adequacy test NEW Results (Pass/Fail) – For•!4 bedrooms Fluid depth in absorption field before test= In. Water added=gal. New depth=in. Elapsed Time: = min. Final fluid depth= in. Absorption rate >= 600+ g.p,d. n• Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE If yes, give date – "SEPTIC SYSTEM SIZED FOR 7 BEDROOMS FOR POSSIBLE FUTURE ADDITION. D. LIFT STATION Date Installed 11/14-11/14-17/20gd Size in gallons 2500 Manhole/Access (Y/N) YES "Pump on" level at TIMER in. "Pump off" level at nMER in. High water alarm level at 44 in. Datum BOTTOM OF TANK Cycles tested 3 Meets alarm & circuit requirements? YES E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ Public sewer main N/A Sewer /septic service line 25'+ On adjacent lots 100'+ Public sewer manhole/cleanout N/A Holding tank N/A Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATIONF, 1 certify that I have determined through field inspections and . ' ':'r review of Municipal records that the above systems are in ""' conformance with MOA COSA guidelines in effect on this JWA, date. •.J r Carn ss.- Engineer's Printed Name JEFFREY A. GARNESS �°� — �Fv 4� s �ia 44�er '•.,fi lf.R o4- Date I 4�edpr COSA Fee 5; Li7)11 cc_pS� Date of Payment Receipt Number in (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number r GRAVEL DRIVE ii50' BLb eATENT ROW RESERVE44 I 00010'05"E464.00- II �. NNco O Z; f o�aw� :(�0 :F•♦ R, .- o tilSn ♦ '� ♦ tea'••. � :.. : • a 03 il r GRAVEL DRIVE ii50' BLb eATENT ROW RESERVE44 I 00010'05"E464.00- II �. NNco O Z; I I 30' g R, I I 0 I I cF tilSn I Im I I� 03 il V 1 1' a-14, n �O F NN Hr�HwgY N 03 rn 8 M = 0 rn porno r (n Z n �O F NN Hr�HwgY