Municipality of Anchorage
Development Services Department ,~'~
Building Safety Division
On-Site Water and Wastewater Program, 4700 Elmore Road ~'~
P.O. Box 196650 Anchorage, AK 99507 Page of
www.ci.anchorage.ak.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: SW090133 PID Number: 012-464-01
Name:
Ali Family Trust Wastewater System: [] New [] Upgrade
Address:
3705 Arctic Blvd., Ste. 1334 Anchorage, AK 99503 ABSORPTION FIELD
Phone: Number of Bedrooms:
727-2912 3 [] Deep Trench if} Shallow Trench [] Bed [] Mound [] Other:
Soil Rating: Total Depth from original grade:
LEGAL DESCRIPTION 1.2 GPD/Ft2 3 Ft.
Block: 2 Lot: 20 Subdivision: Depth to pipe bottom from odginal grade: Gravel depth beneath pipe:
Patricia 1 Ft. 2 Ft,
Township: Range: Section: Fill added above original grade: Gravel Length:
1-2 Ft. 53 Ft.
Well: [] New [] Upgrade Gravelwidth: 5 Ft. Numberoflines:l I Distance between Ii_ .... Ft.
Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material:
AWWU Water System Ft. Ft. 378.5 Ft2 ASTM D3034 PVC
Ddller: Date Drilled: Static Water Level: Installer: Date Installed:
Ft. Glacier Excavating 10/15-20/09
Yield: GPM Pump Set at: Casing Height Above Ground:
Ft. Ft. TANK
SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other:
T~ To Septic Absorption Lift Holding )ublic/Private Manufacturer: Capacity:
From~
Tank Field Station Tank Sewer Line Anchorage Tank 1,250 GaL
Material: Number of Compartments:
we, N/A N/A N/A N/A N/A Steel Two (2)
surface water >100' >100' >100' N/A ~ / LIFT STATION
Size: Manufacturer:
Lot Line >5' 2 .... >5' N/A 1250 STEP Gal, Anchorage Tank/Orenco
"Pump on" level at: "Pump off" level at: in. High water alarm at:
Foundation >5' >10' >5' N/A 42 in. 42 44 in,
Pump Make & Model Electrical Inspections performed by:
Curtain Drain None Noted OS1-P2005-11 Municipality of Anchorage
Remarks:
***See Lot Line Waiver. BENCH MARK
Location and Description:
Absorption Trenches Covered with 2" Direct Bury Insulation. Lower Level Concrete Slab.
Assumed Elevation:
Ft.
Inspections performed by: T. Kimbrough Dates: 1st 10/15/2009
2nd 10/20/2009
~' (-/2.' ~ · ~'~'-~
Development Services Department Approval
Conditional Approval Date:
Reviewed and approved ~' Date:
(Re,. 04/06)
OLYMPIC STREET ~7:~-~'.. ....
· '. :: ..'..'. ;. :- ~ ~ ...'
S O0'02'O0"E 75.00' . :'.. , :. :-
I I ' '.' '- '
I ii ...- ·
I ~
~ ~ ,.: ...
I ~ :
I NN
I
~ : ~ ~ E ~ I
~ · o I o
o~ ~ ~ =,
~0 z ~ , ~ ........ ~
~ al!S OiDU~o
I
I
I ~ x
I
30.0' * '
= ' X ~
,O0'SL ~.00~0.00 N c ~ -
~ ~c
o o ~ ~ ~ ~c
~~~ = o~ E ~3~
~l~ ~ ~ ~ ._
.. : ._
~ ' ' ,o 0
Permit Number: SW090133
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Page 3 of 3
PID No. 012-464-01
STEP Tank
.0_/
~ 100.7 3:_ ;~ 100.4
/
98.5
/ Finished Grade // /
........... Odginal Grade /
Geotextile Fabdc
& 2" Insulation
97.6 Drainfield Rock
95.5 ---' 95.5
J 88.5 53' (Trench Length)
Groundwater @ 91.4
97.6
30 - 5/16" Diameter Holes @ 1.75'
PROFI.LE AS-BUILT
No Scale
Inspection Report
Municipality ,of Aritho ~,, Building Safety Di ision
4700 E!m, ore Road ,V
1NFO & HI~P [907) 3'43-82t 1
INSPECTION: VOICE (907) 343-8~i?0i, FAX (907)249-7777' www.muni.org
Name Bill "
Company Brickwell, Inc.
~ _~? ,..~. ,-- ~,llj~ · 440-9351
Address 10012 OLYMPIC
~ ' Sul~divlslon PATRICIA t LOT 20 B~ 2 TR n/a
Work Deecrtptlor~ 1840 sqft living area, 484iSqft gararge
Insp. performed/prepaid 24 / 23
Permit Technician STULLER, GRETCHE~ J.
Comments or Directions Early AM Please... Call to h~eet- Thanks
Inspection Type Electrical:Final Electrical ~ !.
Comments (for inspector use only)
Inspector
Date
MUNICIPALIT~ OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(9O7) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Date Issued: Jul 31, 2009
Expiration Date: Jul 31, 2010
Permit Number: SW090133
Legal Description: PATRIClA SUBDIVISION BLOCK 2 LOT 20
Design Engineer: 0014 ANDERSON ENGINEERING
Owner Name: ALI FAMILY TRUST
Owner Address: 3705 ARCTIC BLVD #1334
ANCHORAGE, AK 99503-
Parcel ID: 012-464-01
Site Address: NHN GEBHART DRIVE
Lot Size: 7020 SQ. FT.
Total Bedrooms: 3 Permit Bedrooms: 3
This permit is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
A. Waiver WR090045 allows a 2' drainfield to south lot line separation distance.
B.THE ENTIRE SUBSURFACE DISPOSAL FIELD AND ALTERNATE IS NOT WITHIN A 30 FOOT RADIUS OF A
PERCOLATION TEST. THE ENGINEER NEEDS TO DO AN ADDITIONAL PERCOLATION TEST PRIOR TO THE
CONSTRUCTION OF THE SEPTIC FIELD. PLEASE SUBMIT STAMPED AND SIGNED RESULTS WITH THE
AS-BUILT INSPECTION REPORT. IF THE RESULTS REQUIRE A DESIGN CHANGE, CONSTRUCTION OF THE
SYSTEM WILL STOP PENDING ON-SITE REVIEW AND APPROVAL.
Date:
Municipality of Anchorage
~650 ® 4~
Anchoraqe, Alaska 99519-6650 · (907) 343-7904 · Fax {907) 343-7997 ~"
.http:l/www.mun orqlOnslte Department
Development Services Department
On-Site Water and Wastewater Proqram
**** VARIANCE/WAIVER REVIEW ****
WPJh .WR090045 HA//:
PID//: 012-464-01
Legal Description: .Patrlcla B2 L20
Engineer. Anderson Enqineerinq
Permit//: 090133
Applicant: Ali Fatally Trust
Your request for a waiver of the required 10 feet horizontal separation from the absorption field
to the property line has been approved. The approved separation distance is 2 feet from the south
property line.
This waiver approval applies to the existing absorption field to property line separation only.
Any future upgrade to the on-site wastewater disposal system will require all separation
distances be met or another approval from this department.
Waiver Is Granted: X Waiver is not Granted:
Date: 7/31/2009 Approved by .~/J.~g~-~3,fr]~
( ~/Name of Reviewer
Rec//: ,024449 Amount: $200.00 Date Paid: ?~13/09
**** VARIANCE/WAIVER REVIEW ****
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, Alaska 99519-6650
www.muni.org/onsite
(907) 343-7904
ON-SITE SEWER/VVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 012-464-01
Properbj owner(s) Ali Family Trust
Mailing address 3705 Arctic Boulevard No. 1334 Anchorage, AK
Site address GebhartDrive Anchorage, AK
.Day phone 727-2912
.Zip Code 99503
.Zip Code 99516
Legal description (Sub'd,, Block & Lot) Lot 20, Block 2, Patricia Subdivision
Legal description (Township, Range & Section)
Lot Size 7,020 .Sq. Ft. Number of Bedrooms
Three (3)
THIS APPLICATION IS FOR (~;~ all that apply): THIS APPLICATION IS AN:
Absorption Field [] Initial []
Septic Tank [] Upgrade []
Holding Tank [] Renewal []
Privy []
Private Well []
Water Storage []
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: "~
Date of Payment:
Receipt Number:
(Rev. 11/05)
Waiver Fees:
Date of Payment:
Receipt Number;.
~,00
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
July 13, 2009
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Su~e~:
Lot 20, Block 2, Patricia Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 20, Block 2, Patricia Subdivision intends to construct a new three-
bedroom home on the lot. We are therefore requesting a permit be issued for the
construction of a septic system to accommodate the home. The lot and subdivision is
served by the AWWU water system. The attached Site Plan and backup
documentation identify the location and configuration of the proposed septic system
along with the alternate site. No conflicts exist between wells or septic systems in the
area. The lot is very small with only 7,020 square feet of surface area. The absorption
trench must be placed within 2' of the south property line. A lot line waiver request
accompanies this permit application. Drainage arrows are shown on the site plan
showing the grade and direction of flow on the lot. The drainage pattern will not be
changed as a result of this project.
The test holes placed on the lot in the area of the absorption trench and alternate site
indicated sand with gravel and silt (SM/SP). The percolation rate of the soil was
determined to be between 1 and 5 minutes per inch. No groundwater was found during
the placement of the test holes but was noted at 7' during the monitoring period. An
application rate of 1.2 gallons per day per square foot was used in the design of the
absorption system. We are proposing to place a new 1,250-gallon STEP tank and a 70'
;pmh by 5' wide by 2' effective depth absorption trench to treat and dispose of the
effluent generated in the house. The elevation of the distribution line in the absorption
trench will be 1' below the surface and the total depth will be 3'. A minimum of 3' of fill
or 2" of insulation and 2' of fill will be placed over the absorption trenches and 4' over
the STEP tank.
The ground surface on the lot in the area of the absorption trenches is fiat with little or
Lot 20, Block 2, Patricia Subdivision
July 13, 2009
Page Two
no slope in any direction. The new trench will be constructed parallel with the contours
of the surface as much as possible in conformance with Municipal requirements. The
new septic system will be constructed a minimum of 100' from any surface water and
10' from the proposed and existing water services in the area.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
July 13, 2009
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
P.O. Box 196650
Anchorage, AK 99519-6650
Subject:
Lot 20, Block 2, Patricia Subdivision
Separation Distance Waiver
Absorption Trench to Lot Line
Dear On Site Services Engineer:
Lot 20, Block 2, Patricia Subdivision has a surface area of only 7,020 square feet which
greatly limits the space available for a septic system. It is surrounded by subdivisions
currently served by AWWU water and sewer systems. It is also surrounded by 60' and
93' rights of way on two sides. We are therefore requesting a waiver allowing the
absorption system to be placed within 2' of the south lot line. We are also requesting
the alternate site be placed within 2' of the south property line. Soils at this location are
well to poorly graded sand with silt which is normally effective in the absorption and
treatment of septic effluent. Placement of the absorption trench and alternate site
within 2' of the south lot line will not adversely affect neighboring lots. All adjacent lots
are served by the AWWU water system. We hereby recommend a lot line waiver be
issued allowing placement of the absorption systems within 2' of the south lot line.
Sincerely,
Michael E. Anderson, P.E.
o00'0~
OLYMPIC STREET
n
I--J
OLYMPIC
STREET
il
N O0'02'O0"W 75.00'
LOT 20, BLOCK 2, PATRICIA SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Three Bedroom Home 5' Wide Pressurized Trench System
Perc. Rate: 1-5 Min./Inch 1,250 Gallon STEP Tank
Application Rate: 1.2 GPD/SF 2' Drainfield Rock
3 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 375 SF Absorption Area
375 SF/5*.7(Red. Factor) = 52.5 LF Trench Length
THEREFORE: Construct a 53' Long x 5' Wide x 2' Effective Depth Absorption Trench at the
Location Shown. Flow Line Elevation in Trench to be 1' Below Odginal Ground Surface. Total Depth
to be 3' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption
Trenches. Maintain 10' Separation from Water Services in the Area.
ckfill
Geotextile
-- Fabdc
1" Perforated
PVC (Holes Down)
3/16" Dia. Holes
@ 1.75' O.C.
Drainfield Rock
TYPICAL 5' WIDE TRENCH SECTION
(NO SC^LE) ,~;.~..~...~.,
NOTE: Grade Area Over Trench to Dram Away. ~ 49~
Minimum 6' Separation From Bedrock. ~...~...........~...~....[....~
Minimum 4' Separation From Gmund~ter.
Minimum 10' Separation From Water Sewices in ~e Area. ~'~
Minimum 100' Separation From Su,ace Water or Streams' ~;, No
.¸
5-
6-
7-
11-
12-
13-
14-
15-
16-
17-
18-
19-
Performed For:.
Municipality of Anchorage
Development Services Department
Rullding Safety Division
On-Site Water and V~stewater Program
4700 South Bragaw St.
P.O. Box 19~650 Anchorage, AK 995t9-6650
www.munLo*'g/onslte
(907) 343-7904
Soils Log - Percolation Test
Gazmend Arapi
Date Perfon~ed: 4/30/05
Legal Description:
Patrida S/D. BIk 2, Lot 20
lO, O
1 '~C5
Slope
IIIII
I
Township, Range, Section:
Site Plan
WAS GROUND WA~R
ENCOUNTERED? Yes
$
L
IFYE$,ATIM-Ut, TDEPI'H?·7 O
Depfl~ to Water After p
Reading Date Gross Time Net Time Depth to Water Net Drop
1 - 2 4130/05 10:4s- 10:5e 10 s- 0 6
3-4 10:59-11:06 10 6-0 6
5-6 11:07-11:14 7 6-0 6
7-8 11:15-11:23 8 6-0 6
9 - 10 11:24 - 11:34 10 6 - 0 6
11-12 11:35- 11:44 9 6 - 0 6
13 - 14 11:45- 11:53 8 6-0 6
PERCOLATION RA1E 1.5 n~.r. ch) PERC HOLE DIAMETER e
'n[STRUNBE'~/~EEN 2 FT AN{) 2.5 FT
COMMENTS, SP ~an~l
PERFORMED IN ACCORDANCE WITH ALI. STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 20, BLOCK 2, PATRICIA SUBDIVISION
GENERAL:
The scope of this project includes the furnishing and installing of a new
1,250 gallon STEP Tank at the location shown on the site plan. Work
also includes the construction of a new 53' long by 5' wide by 2'
effective depth absorption trench also shown on the Site Plan. A 1.25"
PVC line must be placed between the lift station and the new
absorption trench. The distribution pipe for the trench will be placed at
1' below the ground surface. The total depth of the trench will be 3'.
A minimum of 3' of cover must be placed atop the trench. A minimum
of 4' of cover is required over the Septic Tank and Lift Station with 3' of
cover over the absorption trench. In lieu of cover 2" of direct bury
insulation and 2' of cover may be placed.
Construction shall be in accordance with the approved site plan,
design drawings, Municipal Permit with any special provisions or
conditions, and all applicable State and Municipal Wastewater
Disposal Regulations.
o
The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the
location of all lot lines. Contractor is also responsible to verify the
separation distance from the well on this and adjacent lots.
Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
Contractors installing wastewater disposal systems must be certified
by the Development Services Department Building Safety Division On-
Site Water and Wastewater Program for system installations. Owners
installing their own systems must receive prior approval from the On-
Site Water and Wastewater Program before beginning system
installation.
SEPTIC TANK/LIFT STATION INSTALLATION
1. The 1,250-cjallon STEP Tank must be obtained from a Municipally
approved septic tank manufacturer.
2. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
Lot 20, Block 2, Patricia Subdivision
July 13, 2009
Page 2 of 3
3. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
4. Tanks installed without 4' of cover shall have a minimum of 2" of direct
burial insulation.
A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drain field.
6. Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAIN FIELD CONSTRUCTION:
1. The drain field shall be constructed to the dimensions shown on the
design. The bottom of the bed shall be within 2" of level.
Distribution piping must be placed level with perforations down atop a
level bed of drain field rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drain field
rock and the natural soil backfill.
Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion below the distribution line must be
perforated.
Contractor shall verify the septic tank and drain field are a minimum
100' away from any private water wells in the area, 150' from a Class
"C" Well or 200' from any community well.
Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trenches to drain away.
o
A minimum 2' of accepting soil is required below the drain field rock for
a 5' wide trench. All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
1. The lift station must be constructed by a municipally approved septic
tank manufacturer. An Orenco 20 OSI 05 HHF-5 pump is
recommended.
Lot 20, Block 2, Patricia Subdivision
July 13, 2009
Page 3 of 3
The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated
and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and solid).
Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing
the #200 sieve.
FILTER SAND SPECIFICATION:
1. Material for Filter Sand must be classified as a masonry sand and
meet the following gradation:
50% or More Passing the No. 4 Sieve
2% or Less Passing the No. 100 Sieve
1% or Less Passing the No. 200 Sieve
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These
inspections must be conducted under the supervision of a professional
engineer registered in the State of Alaska. The first inspection must be
conducted after the excavation of trenches, beds or pits and before the
installation of any gravel. A septic tank may be set in place, but may not
be backfilled.
The second inspection must be conducted after the placement of the
geotextile fabric, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as-built of the completed system.
MUNICIPALITY' OF ANCHORAGE
Development Sen/ices Departmont
On. Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Renewal
Date Issued: Oct 06, 2008
Expiration Date: Oct 06, 2009
Permit Number: SW080221
Legal Description: PATRICIA BLOCK 2 LOTS 1 & 20
Design Engineer: 0014 ANDERSON ENGINEERING
Owner Name: ALI FAMILY TRUST
Owner Address: 3705 ARCTIC BLVD STE 1334
ANCHORAGE, AK 99503-
Parcel ID: 012-464-20
Site Address: 10031 GEBHARDT DRIVE
Lot Size: 0 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Cede Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and dosed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
THE MOA L~- ~ I ER OF NON-OBJECTION TO ENCROACHMENT MUST BE SUBMITTED PRIOR TO THE
ASBUILT INSPECTION REPORT BEING APPROVED.
THE UPPER 6" OF THE MOUND SYSTEM IS TO HAVE TOP SOIL AND BE VEGETATED SUFFICIENTLY TO
PREVENT EROSION.
Received By;. ~
Issued By: ~
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, Alaska 99519-6650
www.muni.orglonsite
(907) 343-7904
ON-SITE SEWER/VVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 012-464-20
Property owner(s).Ni Family Trust
Mailing address 3705 Arctic Boulevard, Suite 1334 Anchorage, AK
Site address 10031 Gebhardt Drive Anchorage, AK
Day phone ,727-2912
,Zip Code .99503
Zip Code 99516
Legal description (Sub'd., Block & Lot) Patricta Subdivision, Block 2, Lots 1 & 20
Legal description (Township, Range & Section)
Lot Size 14,040 (Comb~ne~) Sq. Ft. Number of Bedrooms Four (4)
THIS APPLICATION IS FOR ([] all that apply):
Absorption Field []
Septic Tank []
Holding Tank []
privy I--I
Private Well []
Water Storage []
THIS APPLICATION IS AN:
Initial []
Upgrade []
Renewal []
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: t~60
Date of Payment:
Receipt Number. (~/.~ ~- I
(Rev. 11 ~5)
Waiver Fees:
Date of Payment:
Receipt Number.
October 3, 2008
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Su~ect:
Lots 1 and 20, Block 2, Patricia Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lots I and 20, Block 2, Patricia Subdivision intends to COnstruct a new
four-bedroom home on the lot. The septic system was originally designed by Watkins
Engineering in May of 2006 with a permit issued at the time. The permit has since
expired. We are therefore requesting a new permit be issued for the construction of a
new septic system to accommodate the home. The subdivision is served by the AWWU
water system with sewer service also provided on lots to the north. The attached Site
Plan and backup documentation completed by Watkins Engineering identify the
location and configuration of the proposed septic system along with the alternate site.
No existing wells or septic systems are closer than 100' from the proposed septic
system. The majority of the lots surrounding the lot to the south and the east are
currently vacant. The lot is fairly fiat in all directions. The drainage pattern will not be
changed as a result of this project.
The test holes placed on the lot in the area of the absorption bed and alternate site
indicated clean sand (SM/SP) material with some silt at the 8' level. The percolation
rate of the soil was determined to be 1.5 minutes per inch. Groundwater was found
during the placement of the test hole at 7' below the surface and remained at that level
during the monitoring period. An application rate of .8 gallons per day per square foot
was used in the design of the absorption system.
We reviewed the design completed by Watkins Engineering and agree the most
effective system for the lot is a 15' wide by 50' long shallow bed system constructed in
an east-west direction. A 1,500 gallon STEP tank will be required to collect the sewage
from the house and transport the effluent to the absorption bed. The elevation of the
distribution line in the absorption bed will be 2' below the surface and the total depth will
be 2.5'. A minimum of 3' of fill or 2' of insulation and 2' of fill will be placed over the
absorption bed and 4' over the STEP tank.
Lot 20, Block 2, Patricia Subdivision
October 3, 2008
Page Two
The STEP tank will be placed on Lot I along with the house, The absorption bed will
be on Lot 20. Letters of non objection and encroachment permits from the utility
companies have been obtained and previously submitted since the distribution line from
the tank will cross the lot line and utility easements.
The ground surface on the lot in the area of the absorption trench is nearly flat' with a
slight bias to the south. The new bed will be constructed parallel with the slope as
much as possible in conformance with Municipal requirements. The new septic system
will be constructed a minimum of 100' from all wells and any surface water and 10' from
the proposed and existing water services in the area.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The currant drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
GEBHARDT DRIVE
75.00
· ~-:~° ~Id l
I I I
'1 I I
I
I
OLYMPIC STREET
h~c
Performed For:.
Legal Description:
5-
6-
7-
8-
11-
12-
13-
14-
15-
16-
17-
18-
19-
20-
~,0
I0, O
Municipality of Anchorage
Development Services Department
Builcling Safety Division
On~ite 1/~ter and Wastewater Program
4700 South Bragaw St.
P,O. Sox 196650 Anchorage, AK 99519.,6650
www.muflLorg/onsite
(9o7) 343-79o4
Soils Log - Percolation Test
Gazmend Arapi
Patricta S/D, BIk 2. Lot 20
Date Pet?on'ned: 4/30/05
Township, Range, Section:
S;te Plan
WAS GROUND WA3E R
ENC(XJNI~RED? Yes
$
L
IF YES, AT V~AT D~Pll'~? 7 o
Depth to Wate~ A~er
Mo~ltodng? "7. 0 P
E
0.,o: ~.7- 05
Reading Date Gross Time Net Tlme Depth to Water Net Drop
;1 -2 4/30105 10:48-10:58 10 6-0 I 6
13-4 10:59-11:06 10 6-0 6
5-6 11:07-11:14 7 6-0 6
7-8 11:15-11:23 8 6-0 6
9 - 10 11:24 - 11:34 10 6 - 0 6
11-12 11:35- 11:44 9 6-0 6
13 - 14 11:45- 11:53 8 6-0 6
COMMENTS SP ~ar~d from 3' to 8' exceBenl qualf~.
PERFORMED IN ACCORDANCE W1TH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 012-464-01
GENERAL INFORMATION
Complete legal description
Location (site address)
Lot 20, Block 2, Patricia Subdivision
Olympic Street
COSA# O.~ C l g l3.OO
Expiration Date:
Current Property owner(s) Ali Family Trust
Mailing address 3705 Arctic Boulevard, Suite 1334
Lending agency
Day phone 727-2912
Anchorage, AK 99503
Day phone
Mailing address
Real Estate Agent
Mailing Address
Unless otherwise requested, COSA will be held by DSD for pickup.
NUMBER OF BEDROOMS: Three (3)
Day phone
TYPE OF WATER SUPPLY:
Individual Well []
Individual Water Storage []
Community Class ~ Well []
Public Water System []
TYPE OF WASTEWATER DISPOSAL:
Individual On-site []
Individual Holding Tank []
Community On-site []
Public Sewer []
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is {are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Anderson Engineering
Address P.O. Box 240773 Anchorage, AK 99524
Engineer's Printed Name Michael E. Anderson, P.E.
DSD SIGNATURE
'~/'" Approved for -~
Disapproved.
Conditional approval for
bedrooms.
Phone 522-7773
Date 11/7/2010
A
bedrooms, with the following stipulations:
Attachments:
COSA Checklist X
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
.,,:, ./ /
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
Original Certificate Date:
(Rev. 11/05)
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 Elmore Road
P.O. Box 196650
Anchorage, AK 99507
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Lot 20, Block 2, Patricia Subdivision
Legal Description:
A. WELL DATA
Well type AVVVVU
Date completed __
Total depth __
IfA, B, or C provide PWSID #
Sanitary seal (Y/N) ...
Cased to ft.
FROM WELL LOG
Date of test
static water level
Well production
WATER SAMPLE RESULTS:
Coliform colonies/100 mL
Arsenic: ug/I
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material STEP/Steel
Tank size 1,250 gal.
Foundation cleanout iY/N) Y
Date of pumping New
C. ABSORPTION FIELD DATA
Date installed 10/15-20/2009
Length 53 ff.
Tota! depth 4-5 ft.
Parcel ID: 012-464-01
g.p.m.
Nitrate ~ mg/L
Date of sample: ~
Well Log (Y/N)
Wires properly protected (Y/N)
Casing height (above ground) __
AT INSPECTION
Number of Compartments Two
Depression over tank (Y/N)
Pumper Construction
g.p.m.
Other bacteria
Collected by:
Date of adequacy test New Const. Results (Pass/Fail) __
Fluid depth in absorption field before test in. Water added
Elapsed Time: __ min. Final fluid depth
Any rejuvenation treatment (past 12 mo.) (Y/N & type)
Soil rating (g.p.d./~ or ft2/bdrm) 1.2 GPD/SF
Width 5 ft.
Eft. absorption area 378.5 ft2 Monitoring tube
System type 5' Wide Trench
Gravel below pipe 2.o ft.
Y Depression over field N
For bedrooms
~ gal. New depth in.
in. Absorption rate >= .g.p.d.
N If yes, give date
Date installed 10/15/09
Cleanouts (Y/N) Y
N High water alarm (Y/N) Y
~ colonies/100 mL
LIFT STATION
Date installed 10/15/2009
"Pump on" level at 42 in.
Datum Bottom of Tank
SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot
Absorption field on lot
Public sewer main
Sewer/septic service line
Animal containment areas None
Siz~ in gallons ..,3~e~ ~'T'~-1~ Manhole/Access (Y/N) Y
"Pump oR level at 42 in. High water alarm level at 44
Cycles tested 2 Meets alarm & circuit requirements?
in.
On adjacent lots
On adjacent lots
Public sewer manhole/cleanout
Holding tank
· Manure/animal excrete storage areas
None
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >5' Property line >5'
Water main >10' Water service line >10'
Wells on adjacent lots >200'
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 3 ....
Water Service line >1o'
Curtain drain None Noted
Building foundation >1o'
Surface water >1oo'
Wells on adjacent lots >200'
Absorption field >5'
Surface water >100'
Water main >1o'
Driveway, parking/vehicle storage
F. COMMENTS: Property is Served by AWWU Water System. ***See Lot Line Waiver.
G. ENGINEER'S CERTIFICATION
/certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Pdnted Name Michael E. Anderson, P.E.
Date 5/27/2009
COSA Fee $
Date of Payment
Receipt Number
(Rev. 11/05)
O q ll '5
Waiver Fee $
Date of Payment
Receipt Number
FOUND 5/8" REBAR'--~Ii:::).
WEST 100TH AVENUE
N 89'58'50"E 120.00'
LOT 1
16.5' PUBUC USE
EASEMENT
// // //--- // // // //
Icoot
~ / ~.o' COVERED IO.
I J 15.0' ~ ENTRY I
WOODEN FENCE--J ~ ~J /
b 2.0'
J ~ ~1 ~ I '
7,020 S.f. ~ . ~
MH-- ~ ~.o 2 STORY lO.5'?.~- :.:.:. :::JL :.~.-'21 I
' '--g I~J~ RESIDENCE h
coo
WOODEN FENCE~~_
~ ~ S 89'58'50"W 120.00'
~ 10' UTILITY EASEMENT
LOT 2 lO' DRAINAGE & UTILITY
EASEMENT
LOT 19
PLOT PLAN __ AS BUILT ~X SCALE 1" = 30' GRID 2528 Project No. 09-068
La ng (907) 522-6476
Registered Land Surveyors (907) 522-4625
kglanglsOalaska.nef / JclanglsOalaska.nef
& Associates, inc. 11500 Da~/I Avenue, Anchoruge, Alaska 99515-5049
Phone
Fax
I hereby certify that I have surveyed the following described properly:
LOT 20, BLOCK 2, PATRICIA SUBDIVISION (PLAT No. 69-54)
Anchon3ge Recording District, Alaska, and that the Improvements elfuafed thereon are
within the properly lines and do not encroach onto the properb/ adjacent thereto, that
no improvements on the property lying adlacenf thereto encroach on the surveyed
premises and fhaf there are no roadways, fmnsmlssion lines or other visible
easemenf~ on said property except aa Indicated hereon.
Dated this the 3% Day of :::~'~ , ~[o , af Anchorage, Alaska
It is the responsibility of the owner fo determine the exi~fenoe of any easemenf~,
covenants, or resfrlctions which do not appear on the recorded subdivision plat.