MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT
Initial
Permit Number: SWO90065
Legal Description: PETERS GATE, BLK 3 LT 8A
Date Issued: May 19, 2009
Expiration Date: May 19, 2010
Parcel ID: 051-551-14
Design Engineer: 0007 SPURKLAND ENGINEERING Site Address: 25100 MALCOLM DR
Owner Name: DOUG JOHNSON Lot Size: 137957 SO. FT.
Owner Address: 729 N ST Total Bedrooms: 5 Permit Bedrooms: 5
ANCHORAGE. A 99501 -
This permit is for the construction of:
❑d Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By: ���hJ, Date: S ��
Issued By: /IV? 41110 .if/A/f/,Y ti I Date: S ey
a Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.orglonsite
(907)343-7904
ON-SITE SEPTIC/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 1/ 5 1 —gm— y
Property owner(s) Dosj T Day phone
Mailing address 171 N 5frwe+ LCC OC25r. AK Zip Code�-`oL
Site address
Code
Legal description (Sub'd, Block & Lot) Pe4y=aa Gg+e' SK 3 )-.ot SA'
Legal description (Township, Section & Range)
Lot Size 137, 9 57 Sq. Ft.
THIS APPLICATION IS FOR (®all that apply):
Absorption Field
0
Septic Tank
❑
Holding Tank
❑
Privy
❑
Private Well
.9 -
Water Storage
❑
Number of Bedrooms 5
THIS APPLICATION IS AN:
Initial
0
Upgrade
❑
Renewal
❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
property owner or authorized agent)
Permit/Rush Fees: 530'—'-t 2Dol Waiver Fees: _
Date of Payment: 5/1 Up Date of Payment:
Receipt Number: O f y 8 G y Receipt Number:
(Rev. 11105) 0493511 493cII
i -k SPUTMand Efl&awong
Environmental Consulting and Design
SEPTIC SYSTEM DESIGN
PETERS GATE BLOCK 3 LOT 8A
Municipality of Anchorage May 1, 2009
Development Services Department
On Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, Alaska 99519
Subject: Well R Septic Permit
Peters Gate Block 3 Lot 8A
Ladies and Gentlemen:
1 am writing to request a permit for the construction of a new well and septic system for the above referenced
property. The proposed system will serve a 5 -bedroom single-family residence.
System: A 1500 gallon septic tank with a shallow trench absorption field. The absorption field will be 75 feet long
and contain 4 feet of sewer rock.
Soils: Two test holes were excavated on September 9, 2008. See the attached soil logs. Ground water was
monitored for through September 12, 2008. Ground water was not observed.
Surface Water: There are no surface waters within 100 feet of either the proposed septic system area or the reserve
site.
Topography: The property slopes steeply to the south. The proposed house and septic tank will be located along
the north edge of the property. A sewer will extend from the septic tank several hundred feet to a level bench south
of the house. The topography in the area of the drain field is generally level. The absorption field will be installed
perpendicular to the slope.
Waivers: No waivers are required.
The installation of this septic system will not prevent wells and septic systems from being installed on the adjacent
lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of
surface runoff will not result from this installation.
If you have any questions or concerns, please contact me at 279-3916.
Sincerely,
Lars Spurkland, P.E.
Spurkland Engineering
203 Nest 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916
Fax: (866) 354-1597, LspurklandCagci.net
sparN almd Eimukewolmg
Environmental Consulting and Design
SEPTIC SYSTEM DESIGN
Peters Gate Block 3 Lot 8A
Municipality of Anchorage
Development Services Department
On Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, Alaska 99519
October 7, 2008
We are submitting an application for a well and septic system for this lot. The submittal consists of three (3)
drawings showing the present improvements on the lot and the adjoining properties, (sheet 1/3), the proposed
improvements of the lot, of which only the well and septic system are subject to this permit application, (sheet 2/3),
and a schematic of the septic system, (sheet 3/3). Soil logs and percolation tests of applicable test holes are also
enclosed. The septic system design is based on the following:
Groundwater not observed.
Use 1500 gallon septic tank and shallow trench
Soil Rating. From Testhole 9/9/08
4.8 mintin = 12 gal per sq.fi/day
No. of Bedrooms 5
Required Area per Bedroom: 150/1.2 =125 sq.R.
Total arca required: 125 x 5=625 sqR
Bottom Rock At 6 feet
Top Rock At 2 foot
Rock Depth 4 feet
Total Trench Length 625 /5•.50 = 62.5 feet
USE 75 FEET
SYSTEM CONFIGURATION
1500 GALLON STEEL TANK W/ SHALLOW TRENCH
TOTAL LENGTH
75 FT
TOTAL WIDTH
5 FT
TOTAL DEPTH
6 FT
ROCK DEPTH
4 FT
INSULATION
21N.
COVER
2 FT (MIN)
203 West 15'" Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916
Fax: (866) 354-1597, LspurklandCgci.net
LOT 4 LOT 5
MALCOLM DRIVE
O OO
t'; r
LOT 5A
WELL ON TR 18 APPROX. 150'+ SOUTH OF P/L
(` TRACT 1B
Q
NOTE: M IS NOT A SURVEYED PLAT. WELL d SEPMWA
LOCATIONS TAKEN FROM ON-= WATER AND WASTEDEPARTMENT DOCUMENTATRHL All LOCATAONS SNOW
APMX/W lE.
50 0 50 100 150 200 250 300
SCALES 1' = 100 FT
I
LOT BA
I
s
SPURKLAND ENGINEERINGI I PETERS GATE BLOCK 3 LOT 8A I I SEPTIC SYSTEM DESIGN
203 W 151H. AVENUE DOUG JOHNSTON DATE: OCTOBER 7, 2008
ANCH. AK. 99501 729 N STREET, ANCHORAGE, AK 99501 SHEET. 1/3 GRID: NW1162
(907) 279-3916
PERMIT #SV080XXX PID # XXX -XXX -XX PetersGateB3L84DLdw9
rALCllLM.DRIVEINSTALLED 5 -BEDROOM SEPTIC SYSTEM
1500 CAL SEPTIC TANK W/ SHALLOW TRENCH
-2. LENGTH 75 fF£T
WIDTH 5 FEETTOTAL DEPTH 6 fEET
ROCK DEPTH I FEET
7- ------— — INSULATION2INCHES
COVER 2 FEET (MIN)
PIL •%
PRLPQS£D 5-B£A711N ILI'LS£
i
INSTALL DOUBLE CLEAN OUTS EVERY
INSULATE SEWER UNE WHEN BURIAL DEP
LESS THAN 36'. .
LOT SA
NED �J
95 Olt
WELL ON TR 16 APPROX. 150•+ SOUTH Of PA qtr ; _}
49t !V •
TRACT 1B ' ..'
......A�.. ••PURKLAN D
. No. CE -11500 °((���IM
25 0 25 50 75 100 Lz5 Iso ����h�,•..:.� ••
SCALE+ 1' = 50 FT.
SPURKLAND ENGINEERING PETERS GATE BLOCK 3 LOT 8A SEPTIC SYSTEM DESIGN
203 W 15TH. AVENUE DOUG JOHNSTON DATE: OCTOBER 7, 2008
ANCH. AK. 99501 SHEET 2/3 GRID: NW1162
(907) 179-3916 729 N STREET, ANCHORAGE, AK 99501
PERMIT II PID # PetersGateBABABLdwg
O
d
i+
r
1500
Gel. Septic Tank
a
h d
t5
C
�za
q h '%
o
c
Q
C
o
L2
O
c
�........,,'����♦i
��P. ...........
Shallow Trench:
, ♦.
5' Wide
;. , 49th
i..R,......................;..
65 Deep
ot
F` s; LAR�SPURKIAND m
4' Sewer rock
2 -loch Insulation
• i
♦♦ •.,
� T� '"5 t �9 �i�•
2 Cover (ninlnun)
NO SCALE
Monitor
Cleanouts
2' Cover
2 -inch Insula tion
Silt Barrier
4.0 Ft of Septic Rock
1500 Gal. Septic Tank
Effective
NO SCALE
SPURKLAND ENGINEERING
PETERS GATE BLK 3
LOT
8A
SEPTIC SYSTEM DESIGN
An orag Ave
Anchornge Ak 99501
DOUG JOHNSTON
DATE, OCTOBER 7, 2008
p7g-"IK
729 N SIWU. ANCHORALY, AK
99501
SHEET, 3/3 GRID,
NV1162
PERMIT # SV0800XX PARCEL
ID #
PETERSGATEB3L8AD3.DVG
Performed For.
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Boz 196650 Anchorage, AK 995196650
www.munLorg/onshe
(907) $43.7904
Soils Log - Percolation Test
yo.. 7-%'n Son Date Park
ship, Range, Section:
S
L
O
P
E
!r911�/
:49
LAPS L'F% LA .0
11500
Site Plan
Reading
Date
Gross Time
Net Time
Depth to Water
Net Drop
91L09,
0 '
IZN
10 '111c,
If
ID r+'
12 't
1 -4114.,t U+'r
9Ile
It
1*37 ..
ZD wi
lz''
2118'.
n
30 .-,i
IZ. 1/0 of
ION
„
1:57 n
40 w;�
12"
21181r
to q8"
"
7'071..
50 w;.,
12'llL r
17/6"
PERCOLATION RATE (J.8 1-+. ~) PERC HOLE DIAMETER 4.0
TEST RUN BETWEEN 4 FT AND tj FT
COMMENTS Q/( SoaA:60
PERFORMED BY: (AILS SP41 04^1 1 P CERTIFY THAT THIS TEST WAS
PERFORMED IN ACCORDANCE VVITH ALLSTATE AND MUNICIPAL GUIDELI S IN EFFECT ON THIS DATE. DATE:/L og
Soils Log - Percolation Test II Fo
Performed For. P041 f lg nSon Date Performed:
Legal Description: FE}c¢s (rjr- 6 3 L s A Township, Range, Section:
Depth
!/121 ORcsAatc,S
Silt
(ML
13-
1
1
Site Plan
WAS GROUND WATER
.. rr
Municipality of Anchorage
ENCOUNTERED?
Development Services Department
CP
c'
Building Safety Division
/
0 ' 49TH p
On -Site Water and Wastewater Program
4700 South Bragaw St.
•
P.O. Boz 196650 Anchorage, AK 99519.6650
ww907)3.3-7904ite
/
/ • , I. /''� • . r( �MF4'::'S!.
� ?'r,•, LARS E. SPURKLA.\D�
(907)540.79W
/19 '. 11500 i
Soils Log - Percolation Test II Fo
Performed For. P041 f lg nSon Date Performed:
Legal Description: FE}c¢s (rjr- 6 3 L s A Township, Range, Section:
Depth
!/121 ORcsAatc,S
Silt
(ML
13-
1
1
Site Plan
WAS GROUND WATER
.. rr
Gross Time
ENCOUNTERED?
/�/O
Net Drop
9117105
8
IF YES, AT WHAT DEPTH?
tit'-
L
0P
Depth to Water After
Monitoring?
ik
{�-
P
E
Dare:
9
Z
Day
Reading
Date
Gross Time
Net Time
Depth to Water
Net Drop
9117105
1121 f2m
. 0 M;
tit'-
30
Day
38
n;-
11 tt
Sfd !br
0 ity1
2 M;,
II't
511/4r,
DRY
1:55.
3y07".
51 of
r
PERCOLATION RATE1.5_Iewae PERC HOLE DIAMETER
11-- TEST RUN BETWEEN �_FT AND, 5 FT
COMMENTS Ffe So3KED
PERFORMED IN �• DAN J OtM R.1 TATE l CERTIFY THAT THIS TEST
PERFORMED IN ACCORDANCE WI HALL STATE AND MUNICIPAL GUIDELIt ES IN EFFECT ON THIS DATE. DATE: 9 Ir 0 S
Environmental Consulting and Design
Single Family On-site Wastewater Disposal System
Construction and Material Specifications
Subject Property: PETERS GATE BLOCK 3 LOT BA
Date: October 7, 2008
General:
1. The owner shall contract with a contractor to perforin the work outlined in these
specifications and plans in accordance with the attached MOA permit. There is not
contractual arrangement between the contractor and the Engineer. The Engineer shall
be the owner's representative and will inspect the work to document the contractors
activities. Final acceptance of the contractors work rests with the owner and the MOA.
2. The scope of the project includes the procurement and Installation of a 5 -bedroom on-
site wastewater disposal system at the location depicted on the attached site plan
drawings. The scope of the work also includes the installation of a new 1500 gallon
septic tank, a drain field comprised of 1 trenches,S-feet wide x 75 -feet long, 6 feet deep,
with 4 feet of septic rock below the distribution piping. The location of the drain field is
shown on the attached site plan drawings. The total depth of the field will be 6 feet
below the existing ground surface. All components of the proposed septic system must
be constructed a minimum of 100 feet from any surface water or water wells in the area.
A minimum of 4 feet of earthen cover is required over the septic tank and a minimum of
two feet of cover is required over the drain field. In addition to the required earthen
cover, 2 -inch thick, 40 psi, direct bury board foam shall be installed directly over all
installed piping.
3. Construction shall be in accordance with the approved site plan and design drawings and
any special provisions noted on the Municipal well and/or septic permit. All materials,
components, workmanship and construction practices shall comply with the Municipality
of Anchorage's latest ordinances regarding wells and septic systems, as well as MOA,
Development Services Department, On-site Water and Wastewater Program (DSD)
policies.
4. The contractor Is responsible for obtaining all underground utility locates, layout of the
proposed system, and verifying and maintaining all required separation distances to lot
lines, surface water, wells, steep slopes, etc.
S. The property owner shall be responsible for final grading any depressions formed from
settlement of ball material. The property owner is also responsible for vegetation of
all areas disturbed by septic system installation activities.
6. Contractors installing wastewater disposal systems must be certified to do so by the MOA
DSD, On-site Water Wastewater Program. Property owners installing their own systems
must receive advanced approval from MOA DSD prior to system installation activities.
7. The contractor shall ensure that ALL materials being used are in compliance with the
most current guidelines established by the Municipality of Anchorage. Refer to
"Standards and Specifications for Component Parts and Materials Used in the
203 West 15'" Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916
Fax: (866) 354-1597, Lspurkland@gci.net
SpuMaWnd EimpheMBIMP
Environmental Consulting and Design
Null-
Construction of On-site Wastewater Disposal Systems", Dated December 2000, as
provided by MOA DSD, On-site Water and Wastewater Program.
Septic Tank Installation:
1. A new septic tank, of the size specified in the design drawings, shall be procured from a
qualified manufacture/supplier if the existing septic tank Is found to be defective.
Construction shall include two 4" diameter cleanouts for pumping access.
2. The burial rating of the tank shall be adequate for the actual burial depth encountered.
3. The tank shalt be level and sufficiently bedded to prevent settling of shifting of the tank.
4. All standpipes on the tank shall extend a minimum of 12inches above the final grade.
S. Tanks Installed with less than 4 feet of cover shall be insulated.
6. The sewer service line from the house to the tank shall have a minimum slope of 2%
unless prior approval is obtained from the engineer.
7. The inlet and outlet lines from the tank shall be bedded in drain rock or the soil shall be
sufficiently compacted to prevent future settlement of the soil.
8. Septic tank inlets, outlets and deanouts shall be fitted with water tight couplings.
9. A deanout shall be installed 1 to 4 feet from the foundation.
10. Post tank deanouts shall be installed per MOA requirements. Does not apply to
pressurized lines.
11. In areas with high ground water, the septic tank shall be sufficiently anchored to resist
buoyancy forces when there is not adequate soil cover to resist uplift force. The
contractor shall refer to the engineer for direction regarding this matter.
12. The tank backfill shall be graded sufficiently to ensure positive drainage away from the
tank.
13. All holding tank and lift stations shall have an audible and visible alarm Inside the
residence being served.
14. All lift stations shall be wired in compliance with all MOA guidelines and the Uniform
Electrical Code. A municipal electrical permit and inspections must be obtained where
required by the MOA.
15. The contractor shall verify that the septic tank/lift station is a minimum of 100 feet from
any residential water well, 150' from any dass'C well and 200 feet from any community
water wells. Additional separation distances must also be maintained.
16. The contractor shall remove or abandon the existing tank in compliance with the Uniform
Plumbing Code.
Drain field Construction:
1. The drain field shall be excavated to the dimensions outlined in the design drawings. If
any discrepancies are noted, contact the engineer Immediately for clarification.
2. The drain field shall be installed parallel to slope contours.
3. The bottom of the drain field shall be within 2" of level. If the sidewalls or bottom of the
excavation become smeared, they must be raked or scarified prior to the placement of
filter sand or drain rock.
203 West 15'" Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916
Fax: (866) 354-1597, LspurklandCgci.nct
Environmental Consulting and Design
4. The drain field must be a minimum of 5 feet from the test hole excavation.
S. Distribution pipe Is to be installed level with perforations facing downward, atop a level
bed of drain field rock. Septic rock shall then be placed atop the distribution piping to
provide a minimum of 2" of cover, level across the entire width and length of the trench,
above the piping.
6. A silt barrier must be installed at between the final drain rock and the native soil backfill.
The silt barrier shall cover the entire drain rock surface.
7. Monitor tubes must be 4" in diameter, installed In the locations depicted on the design
drawings, and extend a minimum of 12" above final grade. The portion of the monitoring
tube below the septic rock must be perforated and the portion above the drain rock shall
be solid.
8. Backfill over the final gravel layer must not be less than 2 feet. Insulation must be
installed when the ball depth is less than 3 feet.
9. Drain field back fill shall be mounded to prevent depressions from forming due to
subsequent settlement of ball material.
10. The contractor shall verify that the drain field is a minimum of 100 feet from any
residential water well, 150' from any dass'C well and 200 feet from any community
water wells. Additional separation distances must also be maintained.
Inspections:
1. A minimum of two inspections are required by the Municipality of Anchorage. These
Inspections must be conducted under the supervision of a Professional Engineer licensed
to practice in the State of Alaska.
2. The first Inspection must be conducted after the excavation of the drain field and before
the placement of any gravel. The septic tank may be set in place, but may not be
backfilled.
3. The second inspection must be conducted after the placement of the silt barrier, gravel,
distribution lines, stand pipes, ceanouts, and insulation, but before the placement of any
backfill.
4. The contractor shall provide a legible copy of all field notes relating to system layout and
construction to the engineer for the use in preparing the record drawings.
S. The contractor shall coordinate all inspections with the Engineer. A minimum of 24 hours
notice is required prior to the start of construction. If necessary, a preconstruction
meeting will be held on-site.
203 West 15° Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916
Fax: (866) 354-1597, Lspurkland a?gci.net