Loading...
HomeMy WebLinkAboutPETERS GATE BLK 3 LT 8APeters Gate Block 3 Lot 8A #051-551-14 MOA has confirmed that the onsite systems have not been installed. MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SWO90065 Legal Description: PETERS GATE, BLK 3 LT 8A Date Issued: May 19, 2009 Expiration Date: May 19, 2010 Parcel ID: 051-551-14 Design Engineer: 0007 SPURKLAND ENGINEERING Site Address: 25100 MALCOLM DR Owner Name: DOUG JOHNSON Lot Size: 137957 SO. FT. Owner Address: 729 N ST Total Bedrooms: 5 Permit Bedrooms: 5 ANCHORAGE. A 99501 - This permit is for the construction of: ❑d Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: ���hJ, Date: S �� Issued By: /IV? 41110 .if/A/f/,Y ti I Date: S ey a Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.orglonsite (907)343-7904 ON-SITE SEPTIC/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 1/ 5 1 —gm— y Property owner(s) Dosj T Day phone Mailing address 171 N 5frwe+ LCC OC25r. AK Zip Code�-`oL Site address Code Legal description (Sub'd, Block & Lot) Pe4y=aa Gg+e' SK 3 )-.ot SA' Legal description (Township, Section & Range) Lot Size 137, 9 57 Sq. Ft. THIS APPLICATION IS FOR (®all that apply): Absorption Field 0 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well .9 - Water Storage ❑ Number of Bedrooms 5 THIS APPLICATION IS AN: Initial 0 Upgrade ❑ Renewal ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. property owner or authorized agent) Permit/Rush Fees: 530'—'-t 2Dol Waiver Fees: _ Date of Payment: 5/1 Up Date of Payment: Receipt Number: O f y 8 G y Receipt Number: (Rev. 11105) 0493511 493cII i -k SPUTMand Efl&awong Environmental Consulting and Design SEPTIC SYSTEM DESIGN PETERS GATE BLOCK 3 LOT 8A Municipality of Anchorage May 1, 2009 Development Services Department On Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, Alaska 99519 Subject: Well R Septic Permit Peters Gate Block 3 Lot 8A Ladies and Gentlemen: 1 am writing to request a permit for the construction of a new well and septic system for the above referenced property. The proposed system will serve a 5 -bedroom single-family residence. System: A 1500 gallon septic tank with a shallow trench absorption field. The absorption field will be 75 feet long and contain 4 feet of sewer rock. Soils: Two test holes were excavated on September 9, 2008. See the attached soil logs. Ground water was monitored for through September 12, 2008. Ground water was not observed. Surface Water: There are no surface waters within 100 feet of either the proposed septic system area or the reserve site. Topography: The property slopes steeply to the south. The proposed house and septic tank will be located along the north edge of the property. A sewer will extend from the septic tank several hundred feet to a level bench south of the house. The topography in the area of the drain field is generally level. The absorption field will be installed perpendicular to the slope. Waivers: No waivers are required. The installation of this septic system will not prevent wells and septic systems from being installed on the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. If you have any questions or concerns, please contact me at 279-3916. Sincerely, Lars Spurkland, P.E. Spurkland Engineering 203 Nest 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, LspurklandCagci.net sparN almd Eimukewolmg Environmental Consulting and Design SEPTIC SYSTEM DESIGN Peters Gate Block 3 Lot 8A Municipality of Anchorage Development Services Department On Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, Alaska 99519 October 7, 2008 We are submitting an application for a well and septic system for this lot. The submittal consists of three (3) drawings showing the present improvements on the lot and the adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only the well and septic system are subject to this permit application, (sheet 2/3), and a schematic of the septic system, (sheet 3/3). Soil logs and percolation tests of applicable test holes are also enclosed. The septic system design is based on the following: Groundwater not observed. Use 1500 gallon septic tank and shallow trench Soil Rating. From Testhole 9/9/08 4.8 mintin = 12 gal per sq.fi/day No. of Bedrooms 5 Required Area per Bedroom: 150/1.2 =125 sq.R. Total arca required: 125 x 5=625 sqR Bottom Rock At 6 feet Top Rock At 2 foot Rock Depth 4 feet Total Trench Length 625 /5•.50 = 62.5 feet USE 75 FEET SYSTEM CONFIGURATION 1500 GALLON STEEL TANK W/ SHALLOW TRENCH TOTAL LENGTH 75 FT TOTAL WIDTH 5 FT TOTAL DEPTH 6 FT ROCK DEPTH 4 FT INSULATION 21N. COVER 2 FT (MIN) 203 West 15'" Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, LspurklandCgci.net LOT 4 LOT 5 MALCOLM DRIVE O OO t'; r LOT 5A WELL ON TR 18 APPROX. 150'+ SOUTH OF P/L (` TRACT 1B Q NOTE: M IS NOT A SURVEYED PLAT. WELL d SEPMWA LOCATIONS TAKEN FROM ON-= WATER AND WASTEDEPARTMENT DOCUMENTATRHL All LOCATAONS SNOW APMX/W lE. 50 0 50 100 150 200 250 300 SCALES 1' = 100 FT I LOT BA I s SPURKLAND ENGINEERINGI I PETERS GATE BLOCK 3 LOT 8A I I SEPTIC SYSTEM DESIGN 203 W 151H. AVENUE DOUG JOHNSTON DATE: OCTOBER 7, 2008 ANCH. AK. 99501 729 N STREET, ANCHORAGE, AK 99501 SHEET. 1/3 GRID: NW1162 (907) 279-3916 PERMIT #SV080XXX PID # XXX -XXX -XX PetersGateB3L84DLdw9 rALCllLM.DRIVEINSTALLED 5 -BEDROOM SEPTIC SYSTEM 1500 CAL SEPTIC TANK W/ SHALLOW TRENCH -2. LENGTH 75 fF£T WIDTH 5 FEETTOTAL DEPTH 6 fEET ROCK DEPTH I FEET 7- ------— — INSULATION2INCHES COVER 2 FEET (MIN) PIL •% PRLPQS£D 5-B£A711N ILI'LS£ i INSTALL DOUBLE CLEAN OUTS EVERY INSULATE SEWER UNE WHEN BURIAL DEP LESS THAN 36'. . LOT SA NED �J 95 Olt WELL ON TR 16 APPROX. 150•+ SOUTH Of PA qtr ; _} 49t !V • TRACT 1B ' ..' ......A�.. ••PURKLAN D . No. CE -11500 °((���IM 25 0 25 50 75 100 Lz5 Iso ����h�,•..:.� •• SCALE+ 1' = 50 FT. SPURKLAND ENGINEERING PETERS GATE BLOCK 3 LOT 8A SEPTIC SYSTEM DESIGN 203 W 15TH. AVENUE DOUG JOHNSTON DATE: OCTOBER 7, 2008 ANCH. AK. 99501 SHEET 2/3 GRID: NW1162 (907) 179-3916 729 N STREET, ANCHORAGE, AK 99501 PERMIT II PID # PetersGateBABABLdwg O d i+ r 1500 Gel. Septic Tank a h d t5 C �za q h '% o c Q C o L2 O c �........,,'����♦i ��P. ........... Shallow Trench: , ♦. 5' Wide ;. , 49th i..R,......................;.. 65 Deep ot F` s; LAR�SPURKIAND m 4' Sewer rock 2 -loch Insulation • i ♦♦ •., � T� '"5 t �9 �i�• 2 Cover (ninlnun) NO SCALE Monitor Cleanouts 2' Cover 2 -inch Insula tion Silt Barrier 4.0 Ft of Septic Rock 1500 Gal. Septic Tank Effective NO SCALE SPURKLAND ENGINEERING PETERS GATE BLK 3 LOT 8A SEPTIC SYSTEM DESIGN An orag Ave Anchornge Ak 99501 DOUG JOHNSTON DATE, OCTOBER 7, 2008 p7g-"IK 729 N SIWU. ANCHORALY, AK 99501 SHEET, 3/3 GRID, NV1162 PERMIT # SV0800XX PARCEL ID # PETERSGATEB3L8AD3.DVG Performed For. Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Boz 196650 Anchorage, AK 995196650 www.munLorg/onshe (907) $43.7904 Soils Log - Percolation Test yo.. 7-%'n Son Date Park ship, Range, Section: S L O P E !r911�/ :49 LAPS L'F% LA .0 11500 Site Plan Reading Date Gross Time Net Time Depth to Water Net Drop 91L09, 0 ' IZN 10 '111c, If ID r+' 12 't 1 -4114.,t U+'r 9Ile It 1*37 .. ZD wi lz'' 2118'. n 30 .-,i IZ. 1/0 of ION „ 1:57 n 40 w;� 12" 21181r to q8" " 7'071.. 50 w;., 12'llL r 17/6" PERCOLATION RATE (J.8 1-+. ~) PERC HOLE DIAMETER 4.0 TEST RUN BETWEEN 4 FT AND tj FT COMMENTS Q/( SoaA:60 PERFORMED BY: (AILS SP41 04^1 1 P CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE VVITH ALLSTATE AND MUNICIPAL GUIDELI S IN EFFECT ON THIS DATE. DATE:/L og Soils Log - Percolation Test II Fo Performed For. P041 f lg nSon Date Performed: Legal Description: FE}c¢s (rjr- 6 3 L s A Township, Range, Section: Depth !/121 ORcsAatc,S Silt (ML 13- 1 1 Site Plan WAS GROUND WATER .. rr Municipality of Anchorage ENCOUNTERED? Development Services Department CP c' Building Safety Division / 0 ' 49TH p On -Site Water and Wastewater Program 4700 South Bragaw St. • P.O. Boz 196650 Anchorage, AK 99519.6650 ww907)3.3-7904ite / / • , I. /''� • . r( �MF4'::'S!. � ?'r,•, LARS E. SPURKLA.\D� (907)540.79W /19 '. 11500 i Soils Log - Percolation Test II Fo Performed For. P041 f lg nSon Date Performed: Legal Description: FE}c¢s (rjr- 6 3 L s A Township, Range, Section: Depth !/121 ORcsAatc,S Silt (ML 13- 1 1 Site Plan WAS GROUND WATER .. rr Gross Time ENCOUNTERED? /�/O Net Drop 9117105 8 IF YES, AT WHAT DEPTH? tit'- L 0P Depth to Water After Monitoring? ik {�- P E Dare: 9 Z Day Reading Date Gross Time Net Time Depth to Water Net Drop 9117105 1121 f2m . 0 M; tit'- 30 Day 38 n;- 11 tt Sfd !br 0 ity1 2 M;, II't 511/4r, DRY 1:55. 3y07". 51 of r PERCOLATION RATE1.5_Iewae PERC HOLE DIAMETER 11-- TEST RUN BETWEEN �_FT AND, 5 FT COMMENTS Ffe So3KED PERFORMED IN �• DAN J OtM R.1 TATE l CERTIFY THAT THIS TEST PERFORMED IN ACCORDANCE WI HALL STATE AND MUNICIPAL GUIDELIt ES IN EFFECT ON THIS DATE. DATE: 9 Ir 0 S Environmental Consulting and Design Single Family On-site Wastewater Disposal System Construction and Material Specifications Subject Property: PETERS GATE BLOCK 3 LOT BA Date: October 7, 2008 General: 1. The owner shall contract with a contractor to perforin the work outlined in these specifications and plans in accordance with the attached MOA permit. There is not contractual arrangement between the contractor and the Engineer. The Engineer shall be the owner's representative and will inspect the work to document the contractors activities. Final acceptance of the contractors work rests with the owner and the MOA. 2. The scope of the project includes the procurement and Installation of a 5 -bedroom on- site wastewater disposal system at the location depicted on the attached site plan drawings. The scope of the work also includes the installation of a new 1500 gallon septic tank, a drain field comprised of 1 trenches,S-feet wide x 75 -feet long, 6 feet deep, with 4 feet of septic rock below the distribution piping. The location of the drain field is shown on the attached site plan drawings. The total depth of the field will be 6 feet below the existing ground surface. All components of the proposed septic system must be constructed a minimum of 100 feet from any surface water or water wells in the area. A minimum of 4 feet of earthen cover is required over the septic tank and a minimum of two feet of cover is required over the drain field. In addition to the required earthen cover, 2 -inch thick, 40 psi, direct bury board foam shall be installed directly over all installed piping. 3. Construction shall be in accordance with the approved site plan and design drawings and any special provisions noted on the Municipal well and/or septic permit. All materials, components, workmanship and construction practices shall comply with the Municipality of Anchorage's latest ordinances regarding wells and septic systems, as well as MOA, Development Services Department, On-site Water and Wastewater Program (DSD) policies. 4. The contractor Is responsible for obtaining all underground utility locates, layout of the proposed system, and verifying and maintaining all required separation distances to lot lines, surface water, wells, steep slopes, etc. S. The property owner shall be responsible for final grading any depressions formed from settlement of ball material. The property owner is also responsible for vegetation of all areas disturbed by septic system installation activities. 6. Contractors installing wastewater disposal systems must be certified to do so by the MOA DSD, On-site Water Wastewater Program. Property owners installing their own systems must receive advanced approval from MOA DSD prior to system installation activities. 7. The contractor shall ensure that ALL materials being used are in compliance with the most current guidelines established by the Municipality of Anchorage. Refer to "Standards and Specifications for Component Parts and Materials Used in the 203 West 15'" Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland@gci.net SpuMaWnd EimpheMBIMP Environmental Consulting and Design Null- Construction of On-site Wastewater Disposal Systems", Dated December 2000, as provided by MOA DSD, On-site Water and Wastewater Program. Septic Tank Installation: 1. A new septic tank, of the size specified in the design drawings, shall be procured from a qualified manufacture/supplier if the existing septic tank Is found to be defective. Construction shall include two 4" diameter cleanouts for pumping access. 2. The burial rating of the tank shall be adequate for the actual burial depth encountered. 3. The tank shalt be level and sufficiently bedded to prevent settling of shifting of the tank. 4. All standpipes on the tank shall extend a minimum of 12inches above the final grade. S. Tanks Installed with less than 4 feet of cover shall be insulated. 6. The sewer service line from the house to the tank shall have a minimum slope of 2% unless prior approval is obtained from the engineer. 7. The inlet and outlet lines from the tank shall be bedded in drain rock or the soil shall be sufficiently compacted to prevent future settlement of the soil. 8. Septic tank inlets, outlets and deanouts shall be fitted with water tight couplings. 9. A deanout shall be installed 1 to 4 feet from the foundation. 10. Post tank deanouts shall be installed per MOA requirements. Does not apply to pressurized lines. 11. In areas with high ground water, the septic tank shall be sufficiently anchored to resist buoyancy forces when there is not adequate soil cover to resist uplift force. The contractor shall refer to the engineer for direction regarding this matter. 12. The tank backfill shall be graded sufficiently to ensure positive drainage away from the tank. 13. All holding tank and lift stations shall have an audible and visible alarm Inside the residence being served. 14. All lift stations shall be wired in compliance with all MOA guidelines and the Uniform Electrical Code. A municipal electrical permit and inspections must be obtained where required by the MOA. 15. The contractor shall verify that the septic tank/lift station is a minimum of 100 feet from any residential water well, 150' from any dass'C well and 200 feet from any community water wells. Additional separation distances must also be maintained. 16. The contractor shall remove or abandon the existing tank in compliance with the Uniform Plumbing Code. Drain field Construction: 1. The drain field shall be excavated to the dimensions outlined in the design drawings. If any discrepancies are noted, contact the engineer Immediately for clarification. 2. The drain field shall be installed parallel to slope contours. 3. The bottom of the drain field shall be within 2" of level. If the sidewalls or bottom of the excavation become smeared, they must be raked or scarified prior to the placement of filter sand or drain rock. 203 West 15'" Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, LspurklandCgci.nct Environmental Consulting and Design 4. The drain field must be a minimum of 5 feet from the test hole excavation. S. Distribution pipe Is to be installed level with perforations facing downward, atop a level bed of drain field rock. Septic rock shall then be placed atop the distribution piping to provide a minimum of 2" of cover, level across the entire width and length of the trench, above the piping. 6. A silt barrier must be installed at between the final drain rock and the native soil backfill. The silt barrier shall cover the entire drain rock surface. 7. Monitor tubes must be 4" in diameter, installed In the locations depicted on the design drawings, and extend a minimum of 12" above final grade. The portion of the monitoring tube below the septic rock must be perforated and the portion above the drain rock shall be solid. 8. Backfill over the final gravel layer must not be less than 2 feet. Insulation must be installed when the ball depth is less than 3 feet. 9. Drain field back fill shall be mounded to prevent depressions from forming due to subsequent settlement of ball material. 10. The contractor shall verify that the drain field is a minimum of 100 feet from any residential water well, 150' from any dass'C well and 200 feet from any community water wells. Additional separation distances must also be maintained. Inspections: 1. A minimum of two inspections are required by the Municipality of Anchorage. These Inspections must be conducted under the supervision of a Professional Engineer licensed to practice in the State of Alaska. 2. The first Inspection must be conducted after the excavation of the drain field and before the placement of any gravel. The septic tank may be set in place, but may not be backfilled. 3. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, stand pipes, ceanouts, and insulation, but before the placement of any backfill. 4. The contractor shall provide a legible copy of all field notes relating to system layout and construction to the engineer for the use in preparing the record drawings. S. The contractor shall coordinate all inspections with the Engineer. A minimum of 24 hours notice is required prior to the start of construction. If necessary, a preconstruction meeting will be held on-site. 203 West 15° Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland a?gci.net