Loading...
HomeMy WebLinkAboutTUXEDNI PARK BLK 3 LT 3Tuxedni* Park Block 3 Lot 3 #041-022-17 Municipality of Anchorage Community Development Department Page 1 of 2 On-Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite• (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP171245 PID Number: 041-022-17 ❑ New E1 Upgrade Name: DONALD POWELL LIVING TRUST ABSORPTION FIELD Address ❑Q Deep Trench ❑ Shallow Trench ❑ Bed El Mound 9710 COPPER DRIVE ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 0.8GPD/SF 11.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 3.5 Ft. 7.0Ft TUXEDNI PARK 3 3 Fill added above original grade Gravel length Township Range Section 0.0 Ft 54 Ft. Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES 2.5Ft Ft To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 756 Ft2 1 Ft. Well N/A 146.4 N/A N/A 25+ TANK ❑ Septic ❑S.T.E.R. ❑ Holding ❑Other Manufacturer Capacity Surface Water N/A 100+ N/A N/A Gal. Material Number of compartments Lot Line N/A 31.5 N/A N/A -- NA Foundation N/A 55.1 N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain N/A 50+ I N/A N/A Gal. Remarks Pump on level at Pump off level at High water alarm at in. in. in. Pump make and model Electrical Inspections performed by to PIPE MATERIAL House to tank Tank drainfield 3034 Installer WILCO Drainfield 3034 CO/MT r tir, Inspector Pannone Engineering Services BENCH MARK (Assumed elevation) 7 5 14 Inspections, Location and description dates: 1 8/29 /17 2n1 8/30/17 4°' House Trim (Deck) COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp .47,101016.116.100,, Conditional Approval: Date4' .OF AL'4 � 5+� i - __ j*' TH i t .AA F . 'Vteven •FL.•vannorRe•A {141. E 81 Approved 4*--, Date 9-2,C)-(7 ll , ,14 t A\t� Inspection Report_1-1-12.doc -DESIGN PARAMETERS N\ -* �w —WATER1LINE I/ ABBREVIATIONS \ \• \ RESERVE AREA SEPTIC SYSTEM \ \ WELL.-R1ADIU� TH TEST HOLE f- TO BE USED AS PRIMARY \ .;I I r(P) PROPOSED NO. BEDROOM: 4(600 gpd) E TANK SIZE: 1250g \ F2 l NE+I+ s�EP1flC j 1 (E) EXISTING r% ***** I PERC RATE: 11.4 MPI ® CO CLEAN OUT NO. OK ** •4 SOIL RATING: 0.8 GPD/SF 1 \ / 11 MT MONITOR TUBE NO. , AREA RQD: 750 SF 1 / 17s61Em TYP TYPICAL SYS. TYPE: DEEP TRENCH 7.0'ED 1 ) / / * 36a1 1 ` \ MIN LENGTH: 53.6 LF ) / / / \ \ \ TRUE NORTH SCALE : 1'F 50 / (iii. � % 'USED: / / / if \ , \ 54.0LFx2.5'Wx7.0' E.D., 11.0' TD / / / v 17681 \ 1 TOTAL AREA: 756 SF 3/ / i A B /- / / / v \ 1 DV 38.1 37.0 i / / / r f I / // r /� 721 1 • Cl 66.1 _ 56-5 ( / WE_L E / J ' C2 72.5 73.4 / \ I 14.8 1� 146.4 / / � \ 1 \ II 4BR _ / ito 4 .IS" . SF D(E) 4 /4"-,./ TA/2 1994 ATI iH i 7994 ) \\ \ N` / � / \ \ \ ' / ,; / / '," INSTALLED PLANNED RESERVE FIELD( / 54LFx2.5Wx7.0'E.D., 11.0'T.D. / / / / 1 WITH DV AFTER TANK, MTs & COs AT I / / / 1 ENDS OF FIELD /31.5 ) \ I/ / / // // C.1f) 1 76,8 / / / / / / 1 � � � 1 r / �� / l r r (� , \ l C ..,6c!:,!://// re / 11 1r r! \ / /1 • // / / m ------- ,.) 1 ) I / / I i m Y FILTER FABRIC,1 § i DRAIN ROCK 6"ABOVE PIPE INV _ 4"•DRAIN PIPE 0.G./F.G. EL.752 -_- - -_--.-- - - )52.0 1.0 OR 2.0 ML 4t,,:_ +\748.QI _ DRAIN ROCK M1 - - SW 54.0 \741QPROFILE - SCALE 1"=10' - MO -SW 16.0 0,, 734.0 NO GROUNDWATER NOTES: PANNONE ENG SVC, LLC Dote RECORD DRAWING P.O. BOX 102954 ANCHORAGE, AK 995100' 09/01/2017 PHONE (907) 272-8218 FAX (907) 272-8211 ete. Scale *I• • 1- '.* 1" = 50' • �, �t •'• .. + P.I.D. NO TUXEDNI PARK B3 L3 / • - . _041-022-1/ DONALD POWELL LIVING TRUST �Id�even P. Pannone PERMIT NO. DRAWN JRL 8149 9710 COPPER DRIVE �R'• ••. osP171245 • SITE PLAN ANCHORAGE, AK 99507 '1 Sheet 1 I 1 1.. "„ ,,AL, � MUNICIPALITY OF ANCHORAGE rt,e n t ---��R On-Site Water &Wastewater Program tia 5^.. - PO Box 196650 4700 Elmore Road ,. Anchorage.Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 http://www.muni.orglonsite IlL•p.ii tin, lir 4N(MORPVE On-Site Wastewater Disposal System Permit Permit Number: OSP171245 Effective Date: 8/25/2017 Work Type: Septic Upgrade Expiration Date: 8/25/2018 Tax Code Number: 04102217000 Vila 7 80H Ne.0r Site Legal Address: TUXEDNI PARK BLK 3 LT 3 G:2042 Site Mailing Address: 9710 COPPER DR, Anchorage Owner: POWELL DONALD S LIVING TRUST Lot Size in Sq Ft: 97734 Design Engineer: PANNONE ENGINEERING SERVICES Total Bedrooms: 4 This permit is for the construction of: 0 Disposal Field LI Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing lowSpecial Provisions: The permit will be issued to construct a 4 bedroom system. MOA Property Appraisal currently lists the dwelling as a 5 bedroom house. This must be resolved with Property Appraisal prior to Inspection Report approval. ”`"" Proceed at your own risk. """ • I Received By: I 4r� / I Date: `a J• Issued By: a:"'�� 10 Date: SA5 MUNICIPALITY OF ANCHORAGE r �• t � 11 . _ 1 Community Development Department ,ll► Phone: n 0 Development Services Division Fa :617 On-Site Water& Wastewater Program a AUG 22 2017 ON-SITE SEWER/WELL PERMIT APPLICATION lit. 4J5 ,ti w Parcel I.D. 041-022-17 a 6 8 t. Property owner(s) DONALD & KATHY POWELL Day phone Mailing address 9710 COPPER DRIVE, ANCHORAGE AK 99507 Site address 9710 COPPER DRIVE, ANCHORAGE AK 99507 Legal description (Sub'd., Block & Lot) TUXEDNI PARK B3 L3 Legal description (Township, Range & Section) Lot Size 97,734 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (IN all that apply) Absorption Field Initial ❑ Single Family (SF) 0 (w/wo ADU) Septic Tank ❑ Upgrade ❑X Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Munic.•- od s. ignature of property owner or authorized agent) p (!a Permit/Rush Fees: S(I3 r 3y/ I/O Waiver Fees: Date of Payment: �(Z3 /7 Date of Payment: Receipt Number: n`l1 (C$ Receipt Number: Permit No. o5e11 Waiver No. Permit App_ - .:.,c Pannone Engineering Services ac Steven R. Pannone, Principal Registered Professional Engineer E-mail:steve@panengak.com August 23, 2017 Subject: TUXEDNI PARK B3 L3 Upgrade Septic System Permit Request Design Narrative This is a design narrative for a permit to install the reserve absorption field to be issued for this property. The proposed system will serve an existing four (4) bedroom house. The existing drain field is in failure and will be re-used as a reserve. The system will utilize the existing 1250g septic tank and conventional drain field. This lot and the surrounding lots are served by private wells. There are no wells within 100' of the proposed septic system. 1. Soils. Test holes were conducted by S&S Engineering in February 1994, and groundwater was monitored for at least seven days. Ground water was not observed to a depth of 18' below the surface in the test hole monitor tube in February 1994. Bedrock was not encountered in the test hole to 18'. Based on the results of the percolation tests and overall soils appearance; an application rate of 0.8 gallons/day/square was used for a conventional wastewater system in the area of the test hole. 2. Soil Absorption System Design. a. See Sheet 1 of the design package. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 4. Topography: The existing topography on the lot generally slopes from east to west, with a slope of approximately 5%-10% in the area of the drain field. There are no steep slopes in the vicinity of this system. The proposed drain field will maintain 50' separation all steep slopes. 5. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that the review is complete and that there are no further comments is received from MoA On-Site Department, the note will be removed and "Issued for Construction" drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 \ N N. v '` \ `N. ` 'N. \ \ \i \ N \ J W \to / *** y \ \ \ I / / // / i —" � �� \\ \ \ \ ` I / / / / / / �TRUE NORTH SCALE fir- 50'\ 17401 \ \--. f l I t/ / \ \\ A 1 t;/ A / / • / / ) I / \ // 17561I / �f-! M\ .� (M / I } / / 1S` [754 1 J / / / I 1 \• \\ �' / / / / ED \ J _ _ � � � 3/ , , \ \ / / / v \ 1 / / / , /.., _ . / c 17721 �1 . J (- A `) (' I ( �' // 46R W J � '� \ 1 �= *( SFD(E) / ` / 1 ` , 1 \ J 1 Villiwi. - 144.5 - ._�� \ ( / I / 1 ' ' tik r y/ / / 4 l TH Z(i9wl2 lift 1994 / ` ` / • �,,�► / INSTALL PLANNED RESERVE FIELD P ) / 54LFx2.5Wx7.0'E.D.. 11.0'T.D. . . / / 1 WITH DV AFTER TANK, MTs & COs AT I / / / 1 ENDS OF FIELD • / / 21.1 ( )' / ) / ' cy///// / / / / // / �/ 1 N -... \ 41161.6 W �_ / �O�\� / / / / / / V' \ ' ( ) / Il rr Il I \ / /r / ' / ? DESIGN PARAMETERS i) 1 ) 1 r ,' ' RESERVE AREA SEPTIC SYSTEM ) I r / I TO BE USED AS PRIMARY \ J I / /NO. BEDROOM: 4(600 gpd) / ' I / ITANK SIZE: 1250g `_- �? / I / I PERC RATE: 11.4 MPI / J/ / — f- — SOIL RATING: 0.8 GPD/SF / / / / (ABBREVIATIONS AREA ROD: 750 SF / w ATER LINE TH TEST HOLE SYS. TYPE: DEEP TRENCH 7.0'ED WELL RADII � \ (P) PROPOSED MIN LENGTH: 53.6 LF --._/ / / ) (E) EXISTING sS(—mss — NF 7 S TIC i CO CLEAN OUT NO. USE: 1,/,‹ V SMT MONITOR TUBE NO. 54.OLFx2.5'Wx7.0' E.D.. 11.0' TD / I TYP TYPICAL TOTAL AREA: 756 SF / ' I / / �\ 1 ) T r; NOTES: 4 PANNONE ENG SVC, LLC pF Date FOR CONSTRUCTION �C,�e08/21/2017 P.O. BOX 102954 ANCHORAGE, AK 99510 ,�' '•" PHONE (907) 272-8218 FAX (907) 272-8211 �. 1 Scole \lir l'' = 50' , • •• •••• P.I.D. NO TUXEDNI PARK B3 L3 � + .. ` - 0 022-17 DONALD POWELL LIVING TRUST -:156"."0". °� DRAWN JRL CE 8149 PERMIT NO. 9710 COPPER DRIVE ^•' .4 v:08/24/20v OSP171245 SITE PLAN ANCHORAGE, AK 99507 ':�� �` Sheet 1 OF 2 SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS AND AND IN ACCORDANCE WITH AMC 15.65 AND 15.55. 2. SCOPE OF WORK: INSTALL RESERVE SOIL ABSORPTION SYSTEM. 3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 18 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 18 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. 4. THE CONTRACTOR (BOTH WELL AND SEPTIC SYSTEM CONTRACTORS) SHALL HAVE ANY WELL LOCATION AND SEPTIC LOCATION STAKED AND ANY LOT LINE AND WELL RADIUS SHOWN ON THE PLAN WITHIN 30 FEET OF THE PROPOSED SYSTEM STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE WORK. 5. THE CONTRACTOR IS RESPONSIBLE FOR ALL R.O.W. AND OTHER REQUIRED PERMITS, OTHER THAN THE ATTACHED. 6. THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES. 7. THE CONTRACTOR SHALL PROVIDE 24 HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK. ALL SURVEYING AND LOCATES SHALL BE IN PLACE PRIOR TO NOTIFYING THE ENGINEER. 8. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED DRAWINGS AND SITE CONDITIONS/LIMITATIONS POTENTIALLY CAUSING THE NEED TO MODIFY THE DESIGN. 9. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED-LINE AS-BUILT DRAWINGS TO THE ENGINEER. THE RED-LINES SHALL INCLUDE PIPE LENGTHS, ORIGINAL GROUND ELEVATIONS, PIPE ELEVATIONS, AND TANK ELEVATIONS. 10. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE BOTTOM OF EXCAVATION, TOP OF PIPE WITH CLEAN-OUTS AND MONITOR TUBES INSTALLED, INSTALLED TANK AND FINAL GRADING. 11. THE CONTRACTOR PROVIDED DATA (UPON WHICH THIS RECORD DRAWING IS BASED) APPEARS TO REPRESENT THE PROJECT AS CONSTRUCTED. THIS DATA IN CONJUNCTION WITH THE PERIODIC FIELD OBSERVATIONS BY THE ENGINEER (OR HIS DESIGNEE) AS REQUIRED BY AMC 15.65 DOES NOT GUARANTEE THAT THERE ARE NO HIDDEN DEFECTS BY THE CONTRACTOR. 12. THE CONTRACTOR SHALL SIGN THE FOLLOWING: I CERTIFY THAT ALL WORK WAS PERFORMED IN ACCORDANCE WITH THE APPEND PERMIT, AND ANY AND ALL CHANGE ORDERS, AND THAT THE AS-BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS CONSTRUCTED. CONTRACTOR: BY: . TITLE: DATE: NOTES: _ PANNONE ENG SVC, LLCDate �(rG, FOR CONSTRUCTION P.O. BOX 102954 ANCHORAGE, AK 99510 08/21/2017 PHONE (907) 272-8218 FAX (907) 272-8211 .• 4 . Scale *I :* NTS ••• .�a • ••• P.I.D. NO TUXEDNI PARK B3 L3 1, 041-022- 17 DONALD POWELL LIVING TRUST ••tleV°^• OO^^O"e PERMIT No. DRAWN JRL :R CE 8149 9710 COPPER DRIVE .�v 08/24/2q1, OSP171245 DESIGN NOTES ANCHORAGE, AK 99507 •'v� Sheet 2 OF 2 Municipality of Anchorage Page I of Z_ DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SV9y00y0 PID Number: 09/022/7 Name: Wastewater System: XNew ❑ upgrade Address: ABSORPTION FIELD R/DGE FYten6l No. of Bedrooms: X Deep Trench D Shallow Trench ❑ Bed ❑ Mound 0 Other E LEGAL DESCRIPTION Soil Rating: P Total Depth from original grade: GPD/SqFI, Lot: Block: Subdivision:: Depth W pipe bottom from original grade: Gravel depth beneath pipe 9 3 E Ft 7Ft. Township: Range: Section: Fill added above origfnal grade: Gravel length: 1.7 Ft. /� 1S–/ Ft. WELL: XNew ❑ Upgrade Gravel width: Numberoflines: DishnabeMenrina: Ft Ft. Classification (Private. A,8,C): Total Depth: Cased To: Total absorption area: Pipe material: Feb FE,1jF• (of Ft. 06. Ft. 766 so Ft. .n D30?4lP.Y.C. DrIII r Da� rilled Slat Water Tavel: Installer. E0U1P Date installed: j V1-X�I.v /V 6 Ft. EGr4DE Yield: Pump Set at: Casing Rmght Above Ground: , TANK GPM 1✓` Ft. , S Ft. SEPARATION DISTANCES JSSeptic 0Holding ❑S.T.E.P. To Sptic Absorption Lit Holding Capacity In gallons: From Tank Field Station Tank /? co WeIY r al: 5 Number of Compartments: /2 t37' EWatery /� t i� �- LIFT STATIONLot gallons: Manufacturer.Line 70' 2G'Foundation 4a'*aunufa,cturer. �3r 3� v on" level at: Pu level at: High water alarm at: Curtain NONQWNak I Electrical Inspections performed by: DrainRemarks: BENCH MARK on and Description: ♦» — A" Assumed Elevation: /06.00 • ENGINEER'S SEAL `�ader4Cii aOF 2: -`•�G ... ; S & S ENGINELKINQ ^1 17034 Eagle River Loop Road, No. 204 if Inspections performed by: agla Rirer. Alaska 99577 Dates: F 1 2nd 10.6--9ziP. I' -�\ r� ROCERT C. COWAN CE-IIII01 Department of Health -and Human�rvices approval ,., Reviewed and approved b�_� A -2+ / - Date: � tt��lyt;` "_1;» 72-010 (Rev. a/at) MOA 25 Permit NO§W940040 Page 2 of 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 * Anchorage, Alaska 99519-6650 0 Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Legal Descriptio�YXEDNI PARK SUBD., BLOCK 3, LOT 3 PID No.: 04102217 03.2' lc6�& COICO2 t 0 1 FINAL GRADE ....................... ............ .. .......... .. ........... ......................................... . ........................................ . ....................... ..... . ........ ................... ......................................... NEW 89.61, 1250 GAL 89.4' ,9 S.T. SR 88.5' (CO3& C04) .................. NJ's . ...... ..................... . ........................................ . ............. .... . .. .. ....... .. .................... ......................................... . ......................... ............... . .......... :A75.5' NO WATER FOUND NEW 1250 GAL.._ _SEPTIC TANK NEW TRENCH . .ENCROACHMENTS STRUCTURES. EASEMENTS. OR SHOWN ON %,S SITE PLAN ARE AS SHOWN ON A AS -BUTT SURVEY DRAWN BY: CHARLES E. FORDES 4 BDRM t IT IS THE RESPONVRILTTY Or THE CONTRACTOR IQ VM" LASwLmlr� REQUIRED SLPARAT . . ............ .......... . ............ . ........ . .................. . . . .......... .. ................... ......... ...... ....... ...... . 03 INSTANCES, MO PROPER" ONES PRIOR TO t N ­ FCO HOUSE CONSTRUCTION. a WELL CO1 02 BL ED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . t . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . YT C ............. ......... ...... ........... . . .............. ....... ........... - . ................. ..... ........... . . ....... . .......... 7- . .......... . ........... . .. ..... L . •.. . . . ........ . . . . . . . . . . . . . . W SCALE 1" 40' . ............. L- - - - - - - - - - 72-013 A (1/93) ' Nou.15 '94 11:01 3333 BCI Y. TEL 907-345-1354 P. 1 - M -W DRILLING, Inc. 94-151 P.O. Bax 110318 • 10330 Old Snwald Highway . (901)349.8535 - ANCHORAGE, ALASKA 99ri 1 DRILLING LOG Well Owner. Pat atxl Kathy Archie Use of Walt Domestic location (address of: Township, Range, Section, If ]mown; or distance twain road Tnt 1 Blank Mut in -L Park. Size of casing 6 *1-pth of Hola--;101 feet Cased to 100.46 ..��x., . set Static water lever 36 et, (j>y low) land surfacer Finish of well (check one) open end ( X ); Screen ( ); Perforated I..;, a. - Describe screen or perfosati. xA Well pumping test at 10 ` g`;PtF . (minute) for---Z---hours with_ 1flfP/ enr of drawdown from static. 1a, r� :.' "`' •.+rl As Built Note: W(Al dry grouted with 2 Date o! completio J Backs of bentonite ;� _ granules . WELL 100 Depth 1n feet from ground surface 0 TO 2 TO :::� TO TO TO TO TO TO TO of formations penetrated, size of material, color and hardness aWlt"sv Cit1a[S i y Certificate No's, 811 JF: 613 1 —CUSTOMER MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 PAGE 1 OF 1 JX' /°/''j(rw Co /o -3-t ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM,PERMIT PERMIT NUMBER:SW940040 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:SINGLETON JAMES K & OWNER ADDRESS:11531 ROCKRIDGE DR. ANCHORAGE, AK 99516 PARCEL ID:04102217 LEGAL DESCRIPTION: TUXEDNI PARK BLK LOT SIZE: 97734 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 3 LT 3 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: DATE ISSUED: 3/01/94 EXPIRATION DATE: 3/01/95 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 OR 343-4681 AFTER BUSINESS HOURS 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: ISSUED BY: 4'-m-'-' DATE • I �I DATE /`� :0 0 / M F- O J Z H O O Z W Z U 2 0 �3 WaF a� Zzao �4 Z�tWi a Z2W� V1 x WWa,m F•F�Z rrazUWS� OZ3=)Oo Ng�rr�� r-aoNf W W W>-Oq? a F- W m `- O �in�UZ�a W N N p a N 0 rx-��W az Q W o 7 O m W W itW O r7-01 m r K Z w =3 N�FZ . mz 000 00< -.-oo O x '+`: ..•� � n fit. t', Y W �- F (� N _ O a � O s :0 0 / M F- O J Z H O O Z W Z U 2 0 �3 WaF a� Zzao �4 Z�tWi a Z2W� V1 x WWa,m F•F�Z rrazUWS� OZ3=)Oo Ng�rr�� r-aoNf W W W>-Oq? a F- W m `- O �in�UZ�a W N N p a N 0 rx-��W az Q W o 7 O m W W itW O r7-01 m r K Z w =3 N�FZ . mz 000 00< -.-oo T NVId 311S a W l~i Q: p N W0ovai d a' o 0 1 COr. tl o II II CR C7 Ir o I) mJ O W v N to Q .0S = 'j O x O Y W �- F (� N _ O a � O T NVId 311S a W l~i Q: p N W0ovai d a' o 0 1 COr. tl o II II CR C7 Ir o I) mJ O W v N to Q .0S = 'j a 4 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST PERFORMED FOR: f:�4NK &7HAl2D DAT LEGAL DESCRIPTION: 1uxEln.2 PqeL �J. 1_3, &-? Township, Range, Section: SLOPE 1 "';F +� ORGIcS Ma2 A&L - ORGV-he Sr4Ty COAD _a 3 c ' 4- 5- 7 5 7 i 9 D'.1 9- 10 11 b• 12 13 1 ti 14 a) 1 ' J i 15- 16- 17 5 16 17 ° 3•ci. K . 18- 19- 20- COMMENTS 81920COMMENTS [S'rcry S�uo fa WAS GROUND WATER No ENCOUNTERED? S v 7')) IF YES. AT WHAT J L DEPTH? P 707-- E Depth to Wrier After Monitoring? � D g c1q (ENGINEER'S SEAL) or h �y 1 PERCOLATION RATE epi_ (mmv utemch(6 PERC HOLE DIAMETER TEST RUN BETWEEN F) r/ AND h.5 FT J 6 i CIY V IIYL' CR IIY V PERFORMED BFnn�,014 K-91- •.11 ppi e6�' River', '1 ^-F Road Ille- 204 aop X77 1 CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCAMA AIY%TA'4V CDA QCIPAL GUIDELINE/ /Ic T ON THIS DATE. DATE: 72-M (Rev. 4185) (ENGINEER'S SEAL) Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 ; SOILS LOG — PERCOLATION TEST ~ i L�.,� PERFORMED FOR: 28NIC KGTi4AX7 DATE PERFO •��+• °^ LEGAL DESCRIPTION: IUxELWI�RfLc l0, L3A3Township, Range, Section: ���' °•�"' DI:P77 SLOPE SITE PLAN (FEET) 0 n'^,,1" Iffi A 3- 4- 5 45 6- 7- 8- 9- to - 12 7 89 10 12 -,rr slct% Sd>✓D {b LuElL 6aavw Sifr•IO, fnkf 7Q 20 3 13- 14 14- 16- 16 20 COMMENTS WAS GROUND WATER (�\O ENCOUNTERED? 1v IF YES, AT WHAT DEPTH? Depot to wrier Monitoring? li t may, C e, PERCOLATION RATE C (mmutesimch) PERC HOLE DIAMETER i v TEST RUN BETWEEN � /� AND LL 5 FT PERFORMED d:7034 Eagle Rivar Loop Road No. 20d Eagle River, Alaska 99577 ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELIN 72 -MB (Rev. 4/95) [ ~/ CERTIFY THAT THIS TEST WAS PERFORMED IN 'ON THIS DATE. DATE: , s77, fa, • • _� Municipality of Anchorage . „ . On-Site Water and Wastewater Program • i- : �,A'a i i (907) 343-7904 . i SEP t s x lap”, a A c" Certificate of On-Site Systems Approval 1� oc l; s Lc5' Parcel I.D. 041-022-17 Expiration Date: 1 Z`2\-(o —I 1 1. GENERAL INFORMATION Complete legal description Tuxedni Park Block 3 Lot 3 Location (site address) 9710 Copper Dr. Current Property owner(s) Donald Powell Living Trust Day phone Mailing address 9710 Copper Dr. Anchorage, AK 99507 Real Estate Agent Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Q Individual El Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: --- Received Received b : At i419:111/.�1. _ , !J Date: �/2C/17- COSA to be released to the engineer,unless otherwise reque. -. ,y the engineer. COSA Fee $ ca Waiver Fee $ Date of Payment CJ jot.l i a Date of Payment Receipt Number oa5Lect4 Receipt Number COSA# QSC.I-3-1 tAu Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below. ! verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. In conducting an adequacy test, I attempt to provide a thorough,conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations.The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features The operational life of all wells and septic systems depend on the local soil condition,ground water levels that may fluctuate during the year, and the water usage of the family being served by the system.These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system,nor do they guarantee that there are no hidden defects or encroachments.Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Phone (907) 272-8218 Address P.O. Box 100217, Anchorage Ak. 99510 Engineer's Printed Name Steven R Pannone Date 9/1/2017 i�P��OF A•Lgs�l 6. DSD SIGNATURE • M. r ' ' • A. System #1 Approved for y bedrooms >� .Seven R.*'.niton' — /# CE-8149 System #2 Approved for bedrooms /���s'. =� Disapproved �k\ ?OF S`c Conditional approval for bedrooms, with the following stipulations: ``j �JG\e yo ON-Sfl- WAT WASTm EW \- ER ANDATER o PROGRAM ?SERV\CES. By: \ >�r ��- ��• CI Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet f If more than 1 septic system is on the lot: COSA Checklist# of ' Structure served by this system ' Certificate of On-Site Systems Approval Checklist Legal Description: Tuxedni Park Block 3 Lot 3 _ Parcel ID: 041-022-17 A. WELL DATA Well type Private If A, B, or C provide PWSID# _ Well Log (YIN) Y Date completed 10/24/1994 Sanitary seal (Y/N) Y Wires properly protected (YIN) Y Total depth 101 ft. Cased to 100.46 ft. Casing height (above ground) 1 2+ in FROM WELL LOG AT INSPECTION Date of test 10/24/1994 8/15/2017 Static water level 36 ft 31 ft. Well production 10 g.p.m. 4+ g.p.m. WATER SAMPLE RESULTS: Coliform NEG colonies/100 mL Nitrate 4 47 mg/L Arsenic ND ug/L Date of sample: 8/15/2017 Collected by: PES B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 10/4-5/1994 Tank size 1250 gal Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (YIN) N High water alarm (Y/N) N/A Date of pumping 8/14/2017pumper Northland Pumping C. ABSORPTION FIELD DATA Date installed 8/30/2017 Soil rating (g.p.d./ft2 or ft2/bdrm) 0.8 GPD/SF System type Deep Trench Length 54 ft. Width 2 5 ft Gravel below pipe 7 ft. Total depth 1 1 ft. Eff. absorption area 756 ft2 Monitoring tube Y Depression over field N Date of adequacy test NEW Results (Pass/Fail) VA.5,...5 For 11 bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes. give date D. LIFT STATION Date installed Size in gallons Manhole/Access (YIN) "Pump on" level at in. "Pump off level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100+ On adjacent lots 100+ Absorption field on lot 100+ On adjacent lots 100+ Public sewer main 75+ Public sewer manhole/cleanout 100+ Sewer/septic service line 25+ Holding tank 100+ Animal containment areas 50+ Manure/animal excrete storage areas 1 00+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5+ Property line 5+ Absorption field 5+ Water main 10+ Water service line 10+ Surface water 100+ Wells on adjacent lots 100+ ABSORPTION FIELD ON LOT TO: Property line 10+ Building foundation 1�+ Water main 10+ Water Service line 10+ Surface water 100+ Driveway, parking/vehicle storage 10+ Curtain drain 50+ Wells on adjacent lots 100+ F. COMMENTS G. ENGINEER'S CERTIFICATION ~�`"`ik ,l of A/:,1kk, I certify that l have determined through field inspections and ��kP 1,911.-A review of Municipal records that the above systems are in A#• . 1 '.--,\ S conformance with MOA COSA guidelines in effect on this date. 0••• ••_V Engineer's Printed Name Steven Pannone ,- :t}even ..•annone Date 9/1/2017 t+�;i4y� . CE-8149. ' COSA canary sheet_2-6-15.doc / 8341Z co co °p LOT 4 N 11 J o 4'6o Lri 80 ^v OOOO-1'L 11 SSS / 9) / / / / / LOT 3 I / Shed �' 2.0 O / I aft 22? / .. Cleanou 16:3''m �o / �� • Septic vent • =-,,-•, ;,�' �,�, �� 04.0 gspha� / /QQ tis8o • de�ke� ..Z •0 o Well oo GP 11/ y • i s % �� A'4•81 CJCbe' \ , 9-21-17/1#: Q / RECERTIFIED ��' 1\ AS-BUILT NO CORNERS SET THIS DATE 17 LOT 2 �j `�N\% I hereby certify that I have performed a Mortgagee's inspection �►� 44. OF of the following described property: LOT 3. BLOCK 3. O6. / �� • • • . • :;(1 +i TUXEDNI PARK SUBDIVISION O4,/ �' 49th '� • 7 I Anchorage Recording Precinct,Alaska,and that the �� .. ..* / improvements situated thereon are within the property lines 0�� �!` •• •••• and do not overlap or encroach on the property lying (f / adjacent thereto,that no improvements on the property tying '� / Q� 1� t! / adjacent thereto encroach on the premises in question and OC Q Q / .Fred Wal a tk o., / that there are no roadways,transmission lines or other Q , o ;sr*• 3255 - s ••,-' - visible easements on said property except as indicated O es • •• , ' hereon. SCALE: 50' (///.0 V '� �° • • • . • • ,,,,c) ` Dated at Anchorage,Alaska EASEMENTS OF RECORD, OTHER THAN / kp / � 1 1 1, ...re this 15th day of JULY 2009 THOSE SHOWN ON THE RECORDED / J FRED WALATKA&ASSOCIATES PIAT ARE NOT SHOWN HEREON. Forbes Engineers and Surveyors / BE (907-248-1666) Municipality of anchorage " : . , -- l Development Services Department ; 4 r- Building Safety Division r., •,-' On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcell.D.- o91-Oaa-1-7 _ COSA#M0o203 1. GENERAL INFORMATION Expiration Date: / 0 — Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address TUXEDNI PARK: BLOCK 3, LOT 3 9710 COPPER DRIVE ' ANCHORAGE. AK • 99507 PATRICK AND KATHY ARCHEY Day phone 9710 COPPER DRIVE ' ANCHORAGE. AK • 99507 Day phone 240-8035 MARK SOOUET W/ SOOUET REALTY Day phone 727-1616 4155 TUDOR CENTRE 0208 + ANCHORAGE. AK * 99508 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: Individual Well 0 Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ TYPE OF WASTEWATER DISPOSAL: Individual On-site 0 Individual Holding tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,, shows that the on-site water supply and/or wastewater disposal system is (are) sale, functional and adequate for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date 2 09 Engineer's Comments: In conducting this evaluation, GEG. LtD. attempted to provide a thorough, conscientious engineering analysis of the system In accordance with ADEC and MOA DSD Guidelines d Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, not do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE Approved for bedrooms. Disapproved. Conditional approval for bedrooms, with the flowing stipulations: Attachments: / COSA Checklist (/ Septic System Advisory Well Flow Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Nitrate Advisory Other By. RX 1a•+ rimst ..""`�tYtZturrr, OF Aty�y. ON-SITE WATER AND •: �r'' WASTEWATER PROGRAM ' Original Certificate Date: -7 - -7 - 05 ... ........ ...... ' f ey A. 9 ess.: CFr 953 7 Oc,.•'c j F ff cA Conditional approval for bedrooms, with the flowing stipulations: Attachments: / COSA Checklist (/ Septic System Advisory Well Flow Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Nitrate Advisory Other By. RX 1a•+ rimst ..""`�tYtZturrr, OF Aty�y. ON-SITE WATER AND •: �r'' WASTEWATER PROGRAM ' Original Certificate Date: -7 - -7 - 05 Municipality of Anchorage • Development Services Department _ Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: TUXEDNI PARK; BLOCK 3, LOT 3 Parcel ID: OW -02% -.17 A. WELL DATA Well type PRNATE If A, B, or C provide PWSIDN N/A Date completed 10/24/1994 Sanitary seal (YIN) YES Total depth 101 ft. Cased to 100.46 ft, FROM WELL LOG Date of test 10/24/1994 Static water level 36 ft. Well production 10 g.p.m. WATER SAMPLE RESULTS: Well Log (YIN) YES Wires properly protected (YIN) YES Casing height (above ground) 12+ in. AT INSPECTION 6/23/2009 32 ft. 4.52 g.p.m. Coliform Q colonies/100 ml. Nitrate• -rTg./L. Other bacteria 0 colonies/100 ml. Arsenic: /VO ug./L. Date of sample: 6/23/2009 Collected by: GEG Ltd. B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 10/4-5/1994 Tank size 1250 gal. Number of Compartments E Cleanouts'(Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (YIN) NO High water alamt (YIN) N/A I Date of pumping 6/22/2009 Pumper NORTHLAND PUMPING C. ABSORPTION FIELD DATA I'SELOW EXISTING GRADE Date installed 10/4-5/1994 Soil rating .p.d./ rft'/bdrm) 0_8 System type DEEP TRENCH Length 64 ft. Width 3 ft. Gravel below pipe 7 ft. Total depth *11 ft. Eff. absorption area 756 ft' Monitoring lube YES Depression over field NO Date of adequacy test 6/23/2009 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 53 In. Water added690 gal. New depth 79 in. Elapsed Time: 220 min. Final fluid depth67 in. Absorption rate >= 600+ g,p,d, Any rejuvenation treatment (past 12 me.) (YIN & type) NONE KNOWN If yes, give date — D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N "Pump on" level at in. "Pump oft" level High water alarm level at in. DatumCycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankAift station on lot 100'+ Absorption field on lot 100'+ Public sewer main N/A Sewer /septic service line 25'+ Animal containment areas 50'+ On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout N/A Holding lank N/A Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ 1 Water main N/A Water service line t o'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line t o'+ Building foundation 10'+ Water main N/A Water service line t o'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field Inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineers Printed Name JEFFREY A. GARNESS Date -71Z/O9 t� COSA Fee $ LJq Date of Payment -7r � 1 09 Receipt Number ori C) 7 L{g (Rev. 11105) Waiver Fee $ Date of Payment I Receipt Number U u /aZZi7A r O 0 �'n`..R.•'.�..K g�'o o n p e a �n �..n�R•i sen V n ry rt p O •1 • W n H Ri ? n O i n• O Y K • K 10 R h !Y� � Z O n e n [ p n• •� r •' m 6so • �! b 0• 6 b n K� '• b . j VI y o O n b n •C O� -•j b U j �' O K O n y G n S"D�3�:S5S3 .H, .. �• c o;r nen p ,- y n K• a n K V � � 11 • 6 � O .T n n> �O O b O Y• n• n a• n y a^ 0•� n t n J � O b •y ns ^ •<'� no �� j :Ah NM p.. N j ami• T O> W O W O A `n oo inw .nt a0. A 0• >K ^OU O O Sm nr o n > o 0 o n a> n• a n e�.on .+a a • < O G o O 0 0 0 00 VIO X 1 p I �I^IY I -... YMT 1 .. .... �. .. � �.,r♦ I .... ... I ♦ -In• - 1 i.. � .. ...-ry 1 11 N .. I" 6 MUNICIPALITY OF ANCHORAGE •EEO— I RTMENT;OF HEALTH & HUMAN SERVICES Division of Environmental Services On -bite Services Section . -,IPO. Box 196650 Anchorage. Alaska 99519-6650 343-4744q, 7ter CERTIFICATE OF HEALTH AUTHORITY Int APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D.#:: .0 HAA# j-__.�_GENERAL INFORMATION Lot 3; Btack 3; Tuxedni PaAk Complete legal description Location (site address or directions) NHN Twut%a Loop D4.ive AncAo4aae. AK . at 9 K A,%chie ' PKathy)p . erty."owner n er Day phone:* 345-1615 III -C/O Bethajtd Co"tr4action 12801 i ngjadd�:_'_ ress.- R&ta D)cjye:­ An ho AK 99516 Iding ad6ricy. Day phone fing-address Day phone dress Unless otherwise re jpless-otherwisare P r quested, HAA will be held for Icku ER OF BEDROOMS" NUMB : w. jt_Z_ :_7 Pu NOTE::Llfcommunity well system, provide written conflrmai tion from ._'4i'%Wng to the legality and status of system. I 4. TYPE OF WASTEWATER DISPOSAL - X" Holding tank Public sewer NOTE: If community wastewateisystem,'prdvlde written 6onfirmatic attesting to the legallty end status of system-".. 7Z-=(RwAM) Fae W0AW24 . No., Z 0 IEC attest- Z A, tate'ADEC 5. STATEMENT OF INSPECTION BY.ENGINEER,ti ell`1: Yir.+ { �F .+,r• As certified by my seal attixed hereto end as of theT alTdation date a ownrbe. low, I veritythat my investigatloh of this Health Authority Approval epp11 Ill on shows that the on-site water supply and/or wastewater disposal system is sate, functional an"a dequate forlhe numberot bedrooms and type of structure Indicated herein'. I further Verity that based on the lniormation obtained from the Municipalit�l.of Anchorage tiles and from my investigation and.inspection, the on-site water. 4 t supply and/or wastewater itisposa -system I; In compliance wSth all Municipal and State codes, 9 ordinances, and regulations in effect on the date of tflis �nspectio t; j f I 1 y r 1-cl �i .11x�lflla •. :.y f;r r �1./_ � S a 5 ERGWEERLN , t ^ Phone Name of Firm !r' , '17034EeyleRiverL dfJo. i) ':6 ({;,t,°�'•Ilq'.t°"1 Address ' {Date Engineers signature 1 .. .. .. .I , .,�..r r+ .i Fi..rw♦ 4 ,•. �.� ..r.. j• .1� • r ! - - � .._. ., .. �i '' •! :., .ya l' Rt. r{I d�I i \tl.^,.-� fltla .l � .'. ::`. OF A� , ' - I , \q. .. ,. _ . '{ /'• '. 1 1 t. i i,l { 1�'r7 �. \ ,.wn .:w� 1' G,COWA�Nrr✓11wr�_. ��+1 Gy'ti.1EE-8801 €p�J 6 DHHS SIGNATURE i 1,_1 1? 'F �LILL .. t 111 EJ `r r 1'FOfESS1 { —bL Approved for I bedrooms.�r Disapproved" • .11 . t { 0hefollowing stip Conditional approval for 'fibedroomst,witYulations t qn q , 1 f.tY fl il. 14, N , ��, vt� 7 , i. 1 In'j �. d '.'i :.�+t :�i {ZY. .23q :1Crl •10 , ai Yq .ITq, t'. { !, : + 4. '. � �•r�1, L.' � 1 ''1}: '. .' d �. Krr,.,{ ,i� 1.4. •+r�r 1'I ih�itri ILL 1 , ) , i ' 7 II f •.q ,,� a1 ','}r :,!<1.T'. t,t Yt fiW 1'�%i9 /a,, , ,. i ,., It ��'t f-4 1 `' • �. 1 1 1 ♦--7-77777777777711 't�rZ 1 '>il��'�'-='Iqf �, C {'{ { I wit .t rjj%,1 li 1i sit 'm r. 4 'Additional Comments' tif,{JIY .f fi = I: ...•� ,.. , I " S • .f rl,, V`. ]r r{ Irtit f l r-, n41i 2d II . , , , , � "'/ 1 tl {'.. �{.. t. ^:I+ItiA5i1 q`lti(',y �, +r.in.4?ird .t 1�111`'1:1'if I i •. sl - • h ,, tf,14 t�5 ,Z,Tt qt v:.CP tI \ ,�+i �M T.f M'nf :r:{ � IV., r• . Date . By: 141. : , O'_•Y'1 ) loll- I ,.. ....,... The Municipality of Anchorage Department of Health and Human Service (DHHS) Issues Health Authority -Approval ltertiflcates based only upon the representations given, in paragraph,6,ab6ve by an independent professional eq registered in the State of Alaska: The DHHS does this as a courtesy to purchasers of homes and their lending Institutions In order to satisfy certain federal aind state regiiirements. Employees of DHHS do not conduct Inspections or analyze data before a ckficate �s; lasued .Tuhe;TMunicipaliry of Anchorage is not i responsible for errors or omissions In the professional engl jeer s w4 rk t; �In! Lt, te< 724n Mw..1/Rt) Bolick MOA V21I,- ... . Municipality of Anchorage Department of Health and Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description:.L1 4 ill I TAy5L-,o_ T ?R2K Parcel I.D. ()1Y/0,2/ 3t A. Well Data Well type 'f'RIUP, 7F- If A. B, or C, attach ADEC letter. ADEC water system number LJ/4 Log present (YIN) i/%S Date completed 10641941 Driller M -W DRi(4.iu; Total depth X01 '—Cased to loo's, Casing height /� �4 4 - Sanitary Sanitary seat '�P N) YES Wires properly protected &4) y,5S FROM WELL LOG Date of test I6 �aN I9 `i Static water level �6 4 Well flow 10 g.p,m, 1 Pump levell SEPARATION DISTANCES FROM WELL TO: \ AT INSPECTION 2 6Z g.�T fr o � :Z T T M Vl N C in G' Septiclholding tank on lot Ila ;On adjacent lots /00 Z Absorption field on lot 13� 1 ; On adjacent lots /001 Public sewer main 101A Public sewer manhole/cleanout NIA - Sewer service line 16,1 Petroleum tank I�/A WATER SAMPLE RESULTS: Date of B. SEPTIC/HOWMG TANK DATA //--Other bacteria by: S d S ENGINEERING 17034 Eagle River Loop Read fl(Q gH' Eagle River, Alaska 99572 Date installed 10 IS 191 Tank size 1AS0 Compartments o;Z Cleanouts (Y/N) Y6S Foundation cleanout (Y/N) YE Depression (Y/N) High water alarm (Y/N) NI'A Alarm tested (YM) ,J 1A Date of pumping NSA /VE W TANK Pumper Al�i4 6Ur cv TANr, SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s) on lot 1A, On adjacent lots /00 4� Foundation 13 4 To property line 16 44 Absorption field /O Water main/service line ;is Surface water/drainage /00,-/ 72-026(fM*Flom CONTINUED ON BACK PAGE C. LIFT ST ON N//* Date installed Size in gallons Vent (YM) High water alarm level Meets MOA electrical E -Pump on- level FROM LIFT STATION TO: :ss (Y/N) 'Pump off" Levet at Well on lot On adjacent lots Surface water D. ABSORPTION FIELD DATA Date installed ID�SI9`I Soil rating(GPD/Ftz) n.13 Systemtype T,'zEnhcN Length sEi Width 3 Gravel thickness L q Total depth Total absorption area ' 56 S r • Cleanout present (Y/M Depression over field NO 41 Date of adequacy test /U£W -ST. Results (passtfal) _a% 4_for _-L-Bedrooms Water level In absorption field before test (Ifs After test 14K Peroxide treatment (past 12 months) (Y/t# Na If yes, give date ,EVA SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot R;1 , On adjacent lots /od '4 Property line a6 ' To building foundation 3 g To existing or abandoned system on lot /l/1A On adjacent lots oZ t,4 Cutbank ii Water main/service line /O �L Surface water I00 '.I Driveway, parkingivehicle storage area / ) Curtain drain Al/A E. ENGINEER'S CERTIFICATION I cerUfy that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. _t. OF AL.'kh. Signature Engineers Name OratAr C. Date o / / HAA Fee$ Date of Payment Receipt Number 72-028 (last Back C !� ROBERT C. COWAN CE -8801 Waiver Fee $ Date of Payment Receipt Number