Loading...
HomeMy WebLinkAboutDEER PARK #1 BLK 1 LT 9beer Park #1 Block 1 Lot 9 #051 - 042 - 60 Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page of ON -SITE WASTEWATER INSPECTION REPORT Permit Number: OSP231254 PID Number: 051-042-60 Dwelling: 0 Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New 0 Upgrade Name Remasorb LLC ABSORPTION FIELD ❑ Deep Trench 0 Wide Trench ❑Bed El Mound Site Address 22737 Oak Knoll Dr. ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 4.0 GPD/SF 11 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 7.99 Ft. Gravel depth beneath pipe 3.01 Ft. Subdivision Block Lot Deer Park #1 1 9 Fill added above original grade 0.48-1.28Ft. Gravel length 22 Ft. Township Range Section Gravel width 5 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station I Holding I Sewer I Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 189 FF 1 Ft. Well 100+ I 86' I 125+ TANK © Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Capacity Surface Water 100+ 100+ GREER 1500Gal. Material plastic Number of compartments 2 Lot Line 10+ I 10+ I NA Foundation 10+ 10+ LIFT STATION Manufacturer Capacity Gal. Remarks Field verified 10'separation from old fields. Alarm location Electrical installed by Installer PIPE MATERIAL House to tank Tank to D3034 drainfield D3034 Jr's Drainfield D3034 CO/MT D3034 Inspector Areterra Consulting BENCH MARK (Assumed elevation) 100 ft Inspdection 1St 9/21/23 2nd 9/21/23 Location and description 3d 9/22/23 4'h 9/25/23 Garge Slab ON -SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp C F aM,+ ��1�• Conditional Approval: Date t;+��P�"""~"'` 49Ili 0 M Septic System Approved Date 2 30 20 j KENNETH S � C 1 N *'�F Note: this approval does not include well permit requirements. �, 00 (Rev 05102/18) (Metal gate co Storage Well —� I Chimne Y Unsubdivided N89057'45"W 264.49 33' Section Line Easement "� — — — — — — — t - - - I Conc. ret - . wall Asphalt deck ; p, 260 2.0OH Chain link fence CD � 32. N 14.0 .0 c nt 3 Story Frame o Boardwalk CS? �: r as ( @ House 4.0 o o co QD Ret. wall go deck rn 26.0 a- d- W Septic vent (y/p / 1J LOT 9 o ;6{�arixrRFk' � \ / 1 ` 2 Q ONdo pAspha Tank I°v 0 o ��; —Yit- 0 .�� G .> O Iywi g{ ram/) O Zn o Manhole ° C 0 o [�--- Shed � � Rock wall o Z f Wood fence ---1b A a & - N89057'45"W 264.51 Lot 8 AS -BUILT NO CORNERS SET THIS DATE .� r' AW �F ��• . • . �,� t 1 hereby certify that I have performed a Mortgagees inspection in accordance with ASPLS Standards of the following � Q'. ' • .S described property: LOT 9, BLOCK 1, DEER PARK ADDITION No. 1 49th ' • �- 00 Anchorage Recording Precinct, Alaska, and that the 00 ' ' ' ' ' ' ' 00 improvements situated thereon are within the property lines and do not overlap or encroach on the property lying • Of Iizabeth L. Walatka . 'o 00 adjacent thereto, that no improvements on the property lying • �` A0 adjacent thereto encroach on the premises in question and �'� • 803fi - LS .' J7 AW / ' � '�o that there are no roadways, transmission lines or other SCALE: "� 4�' Fo • • .... • "" A)RJ visible easements on said property except as indicated � ` FESS 10NA` hereon. Dated at Anchorage, Alaska this 29th day of September, 2023. EASEMENTS OF RECORD, OTHER THAN 10. 2,0 THOSE SHOWN ON THE RECORDED FRED WALATKA &ASSOCIATES, L.L.C. PLAT ARE NOT SHOWN HEREON BE UNLESS OTHERWISE NOTED. FB 23-3, pg 23-25 Engineers and Surveyors 907-248-1666 This drawing is a representation of conditions found at the time the mortgage location survey was performed. This document does not constitute a boundary survey and is subject to any inaccuracies that a subsequent boundary survey may disclose. The information contained on this drawing shall not be used to establish any fence. structure or other improvements. This drawing shall only be used for a single property transaction. Use of this drawing by the original client or by others at a later date without the consent of Elizabeth L. Walatka is a violation of Federal Copyright law. Unless gross negligence is discovered, the liability extent of the preparer is limited to the amount of fees collected for services in preparation of this product. AS -BUILT SYSTEM DETAILS/SITE PLAN Permit ❑SP231254 DEER PARK #1 BLOCK 1 LOT 9 PID# 051-042-60 -wv+S Y•i: citi r�.z-r. + =.rrr �.�, ti .�•_ �_ :.rr� �'Hi>� 7r� dvwya=c-y:k7 ?a .. ^•.-� ., �-.:5+;•�., �..: jLL.w.� ...titi�iYi' - _r�r'-c :'•.�•- '.� r �.ti'v :•'�:.'�+ti_oLwr^s. iTi-al. I_' Sto I LJ B-C=41,8' o A-11=41,6' B-D=44,3' ;A-E=43,7' m B-E=46,2' A-F=43,5' B-F=45,5' A-G=43,2' " B-15=44,6' A-H=35,1' B-H=28,8' A-I=36,6' B-I=29,5' A-J=32,6' m B-J=17,7' A-K=35,8' B-K=21,0' r I `g e—� - I i F?=100'j / �ECK J f .NTR / Boardv Qlk ,House K-CO M T- J / Asphalt'' / ��a •1: tom`:•• �A�, / .. s.: r5 ;� - r ...fir ...F••. Rock wall O 0 O W W W I Z J J 00 f O s i as w ��u� y 15C0 GAL � SEPTIC Irill ki13 SCALE: NTS Aw OF A 4SS TH * �% 1 KENIVETH M. S CE-71 . wwA# Conc, ret, wall O C3— Shed N 10 98.16 97,g4 FINAL GRADE SCALE: 1' = 30' 98.4 98,6 97.36 89,3 89.3 SEWER ROCK 66.3 B6 3 PREPARED FOR: REMAS❑RB LLC 3317 WENTW❑RTH ST. ANCHORAGE, AK FIELD BOOKS BOUNDARY: N A STMNG: N /A ASBU'LT- WALM DWG. FILE: ACAD FILE` FILE COMPUTED: DRAWN. K S❑ CHECKED: KMo DATE. 10 /18 /: GRID: N W1558 JOB No.: 22176 22' T SCALE: NTS MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP231254 Work Type: Septic Upgrade Tax Code Number: 05104260000 Site Legal Address: DEER PARK #1 BLK 1 LT 9 G:1558 Site Mailing Address: 22737 OAK KNOLL DR, Chugiak Owner: REMASORB LLC Design Engineer: ARC TERRA CONSULTING INC This permit is for the construction of: Effective Date: Expiration Date Lot Size in Sq Ft: Total Bedrooms: �»cnf S, r dIi�` Department 9/6/2023 9/5/2024 43560 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: l S5uf � 12 A4LC 1 f (Z—M Date: Issued By: y Date: r Z02 4 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTICM/ELL PERMIT APPLICATION Parcel I.D. 051-042-60 Property owner(s) Remasorb LLC Day phone Mailing address 3317 Wentworth St. Anchorage, AK Site address 22737 Oak Knoll Dr. Chugiak. AK Legal description (Sub'd., Block & Lot) Deer Park #1 Block 1 Lot 9 Legal description (Township, Range & Section) Lot Size 43,560 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field ❑X Initial ❑ Single Family (SF) 191 Septic Tank ❑X Upgrade FX-1Duplex (w/wo AD U) Tank El Renewal ❑ (D) El Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. Dea Duffus (Signature of property owner or authorized agent) Permit/Rush Fees: 4-59 6- Waiver Fees: Date of Payment: `611y1 Date of Payment: Receipt Number: 003029 Receipt Number: Permit No. 0-510 2- 1� 9 Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231254, Curtis Townsend, 09/06/23 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231254, Curtis Townsend, 09/06/23 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231254, Curtis Townsend, 09/06/23 MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this ��`�'� Day of _- ("o of 20 , by and between t'�3 9� A U. J1 `e, , herein thd'OWNER," and the Municipality of 111) Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as Advantex with AX20 pod located at (legal description) Deer Park #1 Blk 1 Lot 9- 22737 Oak Knoll Dr, ChujZiak 2. Maintenance, Repairs and Alterations. (Owner is required to read, understand and initial each section) Ur— Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. Gam' It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). Of— Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. GC- Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Pagel of 3 Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. Of-- Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. QC/ Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. (t- Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. OR., Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. CW-- Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 OWNER: By: 1`7 jl (signature) Date: (print name) STATE OF ALASKA ) THIRD JUDICIAL DISTRICT ) ss. The foregouig instrument was acknowledged before me this bY�Yl�I SP.f'vFr.� day of Ct/A(14V"(1 20 ay CFO ALAsxA NOTARY My 4mniission expires: b3 oc� D02)— MUN ICIP LIT : By: (signature) Civ �1 S '56'v0 (print name) (rev. 05/ 18/2018) Date Title: C' i vl L- C -•fc (ti6F ,2 Page 3 of 3 MUNICIPALITY OF ANCHORAGE 0 Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Parcel I.D. 051-042-60 Certificate of On -Site Systems Approval Expiration Date: Z� Zo Z y Legal description DEER PARK #1 BLK 1 LT 9 Site address 22737 OAK KNOLL DR Chugiak AK 99567 Current property owner(s) REMASORB LLC X The On -site system(s) is/are approved for 4 bedrooms Conditional approval for Comments or advisories: bedrooms, with the following stipulations: Original Certificate Date: 1 /30/2024 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA Approval_June 2022 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 051-042-60 Complete legal description Deer Park #1 Block 1 Lot 9 Location (site address) 22737 Oak Knoll Dr. Current property owner(s) Remasorb LLC Day phone 2. ON -SITE SYSTEMS SIZED FOR 4 BEDROOMS 3. TYPE OF WATER SUPPLY: ® Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: © Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel ® Plastic ❑ Concrete ❑ Fiberglass Age 0 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: © AWWTS ❑ Bed ❑ Deep Trench ® Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On -site staff to verify the accuracy of the information provided. COSA Fee $ 2�50 Date of Payment 1 / y 2-O Z COSA# 05Caq I0l7 Waiver Fee $ Date of Payment Waiver # COSA Application —June 2022 COSA Checklist Legal Description: Deer Park #1 Block 1 Lot 9 Parcel ID: 051-042-60 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 4/20183 Total depth 405 ft Cased to 395 ft Sanitary seal is functioning correctly © Wires are properly protected Casing height (above ground) 48 in. Date of flow test for COSA 1/5/24 Static water level at beginning of test _EL_ft. Comments B. TANK DATA Measured operating fluid level in septic tank New Date of pumping New Advantex ❑ Required maintenance completed, if AWWTS Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) 9/21/23 ALL standpipes present per record drawing Total measured depth from grade 12.12 ft (max) Measured depth to pipe invert from grade 8.79 ft (min) ❑ N/A — pressurized field. ❑ Per record drawings, field is insulated. R Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Comments/Deficiencies: COSA Checklist June 2022 Well production at time of test 0.5 gpm Water storage tank volume 300 gallons Well disinfected for coliform test? ❑ Yes ✓❑ No ✓❑ Coliform bacteria is Negative Nitrate mg/L ONitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Arcterra Consulting Date 1 /5 . FT STATION ❑ Require tenance completed Age of lift station rs Lift station material Comments: Adequacy test date New Results Q Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd FIELD STATUS — POST RECOVERY Effective depth (per record drawings) 36 in Effective depth used 0 in Effective depth remaining 36 in E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100' Community Sewer Manhole/Cleanout > 100' [Z Yes if No ft ❑✓ Yes if No ft Neighboring Tank > 100' ✓❑ Yes if No ft Private Sewer/Septic Line > 25' �/❑ Yes if No ft Absorption Field on Lot > 100' ❑ Yes if No 86x ft Holding Tank > 100' Q Yes if No ft Neighboring Absorption Fields > 100' Animal Containment > 50' ❑✓ Yes if No it 0 Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ✓❑Yes if No ft ❑✓ Yes if No ft ❑ N/A — Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10' 0 Yes if No ft Surface Water > 100' 0 Yes if No _ Tank to Property Line > 5' © Yes if No ft Wells on Adjacent Lots: Field to Property Line > 10' ❑J Yes if No ft Private Wells > 100' FZI Yes if No _ Water Main > 10' ✓❑ Yes if No ft Community Wells > 200' 0 Yes if No _ Water Service Line > 10' © Yes if No ft If tank or field is under driveway comment below F. ENGINEER'S COMMENTS *Advantex ft ft ft G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on -site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Arcterra Consulting Engineer's Printed Name Kenneth Duffus Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a system will function satisfactory for current or future occupants or can ArcTerra guarantee that no unseen encroachments, deficiencies or discrepancies exist. COSA Checklist June 2022 Phone (907)-696-6111 Date ///4 "4