Loading...
HomeMy WebLinkAboutHIDEAWAY LAKE BLK 2 LT 5Hideaway Lake Block 2 Lot 5 #015-471-16 Municipality of Anchorage Development Services DepartmentBuilding 1�t Safety Division On -Site Water and Wastewater Program, 4700 Elmore St. P.O. Box 196650 Anchorage, AK 99519-6650 Page I of 0X_ ve ve.ci.anchorage.ak.us (907) 3417904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: 'SW R L4 (ie`ty PID Number: 015 ^14 •4 ( — E "p— pName' Nam Y r. a Wastewater System: []New ❑ Upgrade Addles, (l c ABSORPTION FIELD Plwne: Number of Bedrooms 3L4fo ^ l 5 ✓J ( 0 Dealt Tnnrll hNlow Trarrll D Bad o Mound D OUler LEGAL DESCRIPTION SNI RON (9(o GPDM1'T TOM D.pol trom onpnal 94f O Fr. aw4 LO. Sub ian: r �O DepClloppaboeomftom ng.n/�I trade. 10 Gravel dept" benealh ppe'.2 2 0 �Ci Fl. 4.0 Ft Township Rove'. sacbm: Fa Wad above mpnal trade ?• Grew Lerpth:1 0 Ft. 5D 'eO =r 3 41. Well: [New ❑ Upgrade Gravel.ndln: 0 Ft. NurroarOwlee'. 2 Dutana balwaen Nvs' (p , FL ClaaNh (Prime. A. B. C): /1 TOM D.pm, Gwd w /J &I( TOM abe«yum ane /(0o Rpa MawnY: aka /v Ft. FI. Fe 303 ones, , DM nlNd' $b4d Waley level afMAller M1 fez J Date beun f2i T, Ft. ALL 4'14,.,,(/ /H YiNd 3a Pump Bal a1. CateN HNthl ADova G1ou1tl. TANK GPM MIt wiwh ct. (. FL SEPARATION DISTANCES Ispeptic ❑ Holding ❑ S.T.E.P. ❑ Other. To Septic Absorption Lift Holding lublicriorlyale °'•° •paaly. From Tank Field Station Tank Sewer Line ny 2, GM. Wen iod-«— Matanal Number O Companm.ms. suds«walar (00 ( / LIFT STATION Lot Una $ 0 3 r H. Gal •0.101. FeuM•tron r ' 'Pump on 16v at •Pump ofr IavN at. 14th"ler Mame OL / f- �o -f- In. n ;n. . I / / Pump Maxa 6 ModN LlegrwM a,spactms pedby: Rom x BENCH MARK Locum arw Dsampoon. O/A G • mW iav4m: �V(] r FL I Inspections by: r7 Tin arfl.y,1�rlc�.rip,-F Dates: tat G Engineer's Stamp performed OF Al X% 2^d/66 �-�E ff Development Services Department Approval -%y�P•'•'' ;rp f/ Conditional Approval Date: .y 49TH a ....:... Ib • MICHAEL N. ANDERSON . / .00 Reviewed and approved by: W t Date: cRr awal ��\� RQFES����e-`t` Permit No. SW940084 Page 2 of 3 DATE: 7/8/2009 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 Anchorage, Alaska 99519-6650 Telephone: 343-4744 On—Site Wastewater Disposal System and/or Well Inspection Report Legal Description: HIDEAWAY LAKE, BLOCK 2, LOT 5 PID No.: 015-471-16 �\\ T I 1 HARK A 8 GRND PIPE \ \ \\ •,A, _ _ _ �\ _ _ _ ELEV. ELEV. \ / G01 24 25 106.1 1018 002 25 25 106.1 to18 TC01 23 28 106.2 \ x Y TCO2 18 36 106.2 DIV. 16 40 106.2 1013 \ / 003 12 42 108.3 103.3 004 74 123 106.2 1013 \ / I 005 10 60 104.4 101.1 1 r / C06 13 62 104.4 101.1 C07 58 112 104.3 101.1 i MTI 60 105 106.2 I I :04 IMT2 132 ISO 1104.51 - YT1 YY®L 1 Tllj2 C07 I I l k I WT2 1 / I I DMS TCO1 1.250 GALLON POSTING SEPTIC TANK HOUSE 002 100' WELL RADIUS J l 1 -LOT 5-I 1140' \ SCALE: xwaw Sam m em cw w o n. , �♦ ��CF • ns ar ♦1'`P.•'.... ....... • •��1 I J wia ,w[ �'..J...... •. .........i.. ..� • rw Lao 1�EL N. ANDERSONr i �No. CE 9469 -Luo rrt. �• ♦♦ py♦ 46081•U �♦ LLS�SQmI Biu Michael N. Anderson, P.E. Civil/Structural Engineering 4661 Natrona Ave. Anchorage, Alaska 99516 Phone 345-3377 Far 345-1391 July 19, 2009 Municipality of Anchorage Department of Health and Iluman Services P.O. Box 196650 Anchorage, Alaska 99519-6650 Re: Lot 5 Block 2 Hideaway Lake Subd. Dear Jet, Please consider this my official letter requesting that the replacement site for the above lot, be an Advantex system due to well radius and o5pp5eenwateroffsets. A5 ori �r;s�t•K, i..n.ti t—+vpbre� w� tJ*W Str4{TM % J�(�r40 i"r,. If you have any question please call me at 345-3377 Sinc/e�An Mic 6n, P.E. STATE OF ALASKA DEPARTMENT OF NATURAL RESOURCES DIVISION OF WATER WATER WELL RECORD LOCATION OF WELL BOROUGH SUBONISION LOT BLOCK SECTION OTItS SECTION TOWNSHIP RANGE MERIOIAN I ON 0 I Os OW LOCATION/SKETCH: y WELL OWNER: DEPTHS MEASURED FROM:❑casing top ❑ground surface WELL DEPTH: DATE OF COMPLETION Depth of hole: ft BOREHOLE DATA: Depth Depth of casing: --/ It % Material Type and Color From TO DEPTH TO STATIC WATER LEVEL - It below ❑ top of casing ❑ ground surface Date* + , METHOD OF DRILLING: ❑ air rotary ❑ cable tool ❑ other USE OF WELL: ❑ domestic ❑ irrigation ❑ monitor ❑ public supply ❑ other CASING STICK-UP: I Diam: in. toit Casing type:.', , � in. to G, 'r ft WELL INTAKE OPENING TYPE: ❑ open end ❑ screened _ ❑ perforated .❑ open hole Depths of openings: to It SCREEN TYPE: Diam: in. Slot/Mesh Size: Length: It GRAVEL PACK TYPE: Volume used: Depth to top: GROUT TYPE: Volume: Depth: from ftto It DEVELOPMENT METHOD: •'1 Duration: 1/1'. PUMPING LEVEL AND YIELD: /` ? ftafter hrspumping • g ] pm PUMP INTAKE DEPTH: It Horsepower. WELL DISINFECTED UPON COMPLETION? EI YES ❑ NO If CONTRACTOR INFORMATION: Registered Business Name Signature of Authorized espresentative Uatm e REMARKS: PLEASE MAIL WHITE COPY OF LOG TO: DNR/DIVISION OF WATER PO BOX 772116 EAGLE RIVER AK 99577.2116 MUNICIPALITY OF ANCHORAGE 16r DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 PAGE 1 OF 1 9/3/5q c "lop'n 2"%44T12.kv e) q 3O ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW940084 DATE ISSUED: 4/21/94 DESIGN ENGINEERS & S ENGINEERING EXPIRATION DATE: 4/21/95 OWNER NAME:AUGDAHL ROGER W & OWNER ADDRESS:11101 HIDEAWAY LAKE CIR ANCHORAGE, ALASKA 99511 i PARCEL ID:01547116 QO Non\\w LEGAL DESCRIPTION: HIDEAWAY LAKE BLK 2 LT 5 �� @ LOT SIZE: 52596 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 OR 343-4681 AFTER BUSINESS HOURS 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: ISSUED BY: DATE: DATE: A HEALTH AUTHORITY APPROVALS SEWER WATER MAIN EXTENSIONS SEWER 8 WATER INSPECTION AND REPORTS k= April 10, 1994 PA ) of Anchorage NT OF HEALTH AND HUMAN SERVICES 25 'L' Street .O. Box 196650 nchoraae. Alaska 99519-6650 Hideaway Lake Subdivision, Block 2, Lot 5 Permit #SW910129 ROBERT SHAFER, P.E. ROGER SHAFER, P.E. CIVIL ENGINEERS (907)694-2979 FAX 694.1211 guest you re -Issue a permit #01547116 with a design change to eliminate spill-over trench as shown on attached site plan. WELWSPECTION 8 FLOOW TEST Test holes were excavated and percolation tests performed. The approximate location of the test holes are located on the attached site plan. At the time of excavation water was encountered at 10.5 feet & 10 feet in test holes one and two respectively and after seven day water monitoring water was found at 10.5 517E PLANS feet and 10 feet respectively. This property has enough area for a future septic upgrade which can be seen on ROAD DESIGN the attached site plan. We do not anticipate any adverse effects on neighboring properties by the installation of the proposed septic system. SOILTEST PERCOLATION TEST STRUCTURAL& MECHANICAL INSPECTIONS ON SITE WASTEWATER DISPOSALSYSTEM DESIGN If you have any questions, or require additional information for your review, Shafer, P.E. 17034 NORTH EAGLE RIVER LOOP - SUITE 204 - EAGLE RIVER, ALASKA 99577 SCALE �K �5T1aE, Ew art L, 1 �iMM.+- �S �i 0&rlr4z L Mta. of t0a' a s_�,•�-tom Sym. At\ 4- V7. I oo 5c, 4-e�v., : (000 ' JSP 6 1250 Goa_. .56F�flc. •s,�itJ, a Ito - Z9 NirJ./►� I 0 1�i r�-Eta�Ei• - �}' � y' WttaE I +� 3 CSF-+oN�l- � Acvc-Cl F "Oe .F •� r AI,T�iJ 1� 1�v`1 C�11u. •Pt�1t� v` � LOT 5.17-1 lorl Zk Ytl � p 0&rlr4z L Mta. of t0a' a s_�,•�-tom Sym. At\ 4- V7. I oo 5c, 4-e�v., : (000 ' JSP 6 1250 Goa_. .56F�flc. •s,�itJ, a Ito - Z9 NirJ./►� I 0 1�i r�-Eta�Ei• - �}' � y' WttaE I +� 3 CSF-+oN�l- � Acvc-Cl F "Oe .F •� r AI,T�iJ 1� 1�v`1 C�11u. •Pt�1t� v` � LOT 5.17-1 lorl IrN L� O if 0 W U E— ¢ a K Z5 � x a z a m O l N \ �D oo N W F- Q ov H 70 � cr s vicr P y J F— W o d 4 Y U 'NIW .Z U N W F- 2 J Una . Vl J z a 3 c� a w ¢ J O ti N s e ttt � r 4 inr,7$ 11V130 .0b = -,j ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS REFERENCE. Hideaway Lake Subdivision, Block 2, Lot 5 GENERAL: 1. The scope of this project includes the installation of a 1250 gallon septic tank and a leachfield trench to serve the proposed four bedroom residence on the referenced property. 2. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with anyspecial provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The contractor shall be responsible for obtaining any necessary underground utility locates. 4. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. On all leachfield mound systems, the property owner shall be responsible forensuring a satisfactory vegetation growth over the mounded area. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. SEPTIC TANK INSTALLATION: A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4' cleanouts for pumping access. 2. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 3. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. Page Two Hideaway Lake Subdivision, Block 2, Lot 5 April 10, 1994 4. Septic tanks installed with less than 4 ft. of cover shall be insulated. 5. A foundation cleanout shall be Installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 /t. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. 6. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INSTALLATION. Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. if the sidewalls of the excavation become smeared, they must be raked or scratched (ruffed -up) before gravel (sewer rock) placement. 2. Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. 3. A silt barriermust be installed between the final gravel layerand the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. 4. Monitor tubes shall be of four (4) inch diameter and installed approximately in the locations shown on the design. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. 5. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. Page Three Hideaway Lake Subdivision, Block 2, Lot 5 April 10, 1994 MINIMUM MATERIAL SPECIFICATIONS: 1. Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations In the Municipality of Anchorage: Type of Pipe Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. 3. Insulation shall be at least 2' thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable nontoxic silt barrier (fypar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. 6. All leachfield gravel (sewer rock) shall be 0.5'-2.5' screened gravel with less than 3% passing the #200 sieve. 7. When sand is being used as a filter material, it's gradation specifications must conform to current M.O.A. or D.E.C. requirements. Page Four Hideaway Lake Subdivision, Block 2, Lot 5 April 10, 1994 INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. 2. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. 3. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre -construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR/OWNER Munlclpality of Anchorage ` ... DEPARTMENT OF HEALTH 11 HUMAN SERVICES ' 825'L" Street, Anchorage, Alaska 99502-0650 ....... SOILS LOG — PERCOLATION TEST A, Er.sa F.�CiG I`�` 1 'Vim,/��` '��,..�I1'r .'•. \;•r�\77�� I✓ PERFORMED FOR: OA PERFORMEW '�"'Y••�•'•� LEGAL DESCRIPTION: l.)yv V�j064 w./ L44.• Township, Range, Section: 1 e, . ^a 2- 3- 3 �� ' _ - • t/I Ai - lo�v a r o 5 7 b -KSPMWI e 44.0 ! V' 7 �• 8 a.. 10 11 p _•n 12 7. - 3 13- 0e 14- 1415 15 16 17- 18- 19- 20 7181920 COMMENTS SLOPE WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Depth to Willer Alter/ Mmllerinpl I O Due. !6L .�' el PERCOLATION RATE (minuteyneh) PERC HOLE DIAMETER TEST RUN DETWEEN R FTAND --+— FT PERFORMED BY) 7 J34 f.a0lo River Loop Road fl ,104 77 ff"" ACCORDANCE W -tH ALL ST TE AND MUNICIPAL GUIDELI 72-008 (Rev. 4185) lllll���.. �— CERTIFY THAT THIS TEST WAS PERFORMED IN ON THIS DATE. DATE: 2—. G — ` r �� ' _ - • lJ�ilE�lit� MIMI -KSPMWI .�' el PERCOLATION RATE (minuteyneh) PERC HOLE DIAMETER TEST RUN DETWEEN R FTAND --+— FT PERFORMED BY) 7 J34 f.a0lo River Loop Road fl ,104 77 ff"" ACCORDANCE W -tH ALL ST TE AND MUNICIPAL GUIDELI 72-008 (Rev. 4185) lllll���.. �— CERTIFY THAT THIS TEST WAS PERFORMED IN ON THIS DATE. DATE: 2—. G — ` r I * PERFORMED LEGAL . 2 •�.l �a 3 4 1,F. :{ / 7- 8- 9- 12- 13- 14- is- 16- 17- 18- 19 - 2o4 891213 14151617181920 COMMENTS .;SSG(f19i31NE fiS�EAL) • .> •„ •SEE} Municipality of Anchorage 211 DEPARTMENT > : '�..3° `•. ti G' �d DEPARTMENT OF HEALTH d HUMAN SERVICES 825 `L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST eoe•A• [,;%u':vk r•:'J. r • '• w t4i%i � J�•O F.TA � 1/S? 0 Township, DATE Section: 1 /`� WAS GROUND WATER • /�� /,/K' ✓t— ENCOUNTERED?�%((j7_ S IF YES, AT WHAT L DEPTH? 0 P E Depth to Water Alter I OI 2-167L ' I Q Monitoring? Dale: 1� PERCOLATION RATE —A—Le— (minuteLinth) FERC MOLE DIAMETER TEST RUN BETWEEN ,�qZp — FT AND 'I FT PERFORMED 837034 Eaolo River Loop Road No. 204 Eag a IvCrl—i'�I2Skr97SI/ ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDEL14 72-008 (Rev. 4185) CERTIFY THAT THIS TEST WAS PERFORMED IN ON THIS DATE. DATE: Z r J ---v r o L4[T•��!•�C1�L'�I�f�TEi� 1� PERCOLATION RATE —A—Le— (minuteLinth) FERC MOLE DIAMETER TEST RUN BETWEEN ,�qZp — FT AND 'I FT PERFORMED 837034 Eaolo River Loop Road No. 204 Eag a IvCrl—i'�I2Skr97SI/ ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDEL14 72-008 (Rev. 4185) CERTIFY THAT THIS TEST WAS PERFORMED IN ON THIS DATE. DATE: Z r J ---v r MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW910129 DESIGN ENGINEER:S & S ENGINEERS OWNER NAME:AUGDAHL ROGER W & OWNER ADDRESS:P.O. BOX 110711 ANCHORAGE, ALASKA 99511 PARCEL ID:01547116 LEGAL DESCRIPTION: HIDEAWAY LAKE BLK 2 LT 5 LOT SIZE: 52596 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 PAGE 1 OF 1 DATE ISSUED: 6/04/91 EXPIRATION DATE: 6/04/92 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PR RECEIVED B ISSUED BY: DATE• ` DATE:6� 7 - / ROBERT SHAFER, P.E ROGERSHAFER CIVILENGINEERS (907) 8942979 FAX 694.1211 May 31, 1991 NEALTH AUTHORITY APPROVALS Municipality o6 Anchotage DEPARTMENT OF HEALTH AND HUMAN SERVICES 825 L Street SEWER&WATER P.O. Box 196650 MAIN EXTENSIONS Anchorage, Atka 99519-6650 REFERENCE: Lot 5; Btock 2; Hideaway Lake Subdivision; SEWER& WATER INSPECTION PERMIT REQUEST NARRATIVE Request you .issue a permit to .inatatt the proposed on-a.ite wett and ENGINEERING STUDIES AND REPORTS septic system aA shown on the attached site. tan. P y P We have proposed dtain6ietd trenches to be .insta.tted down the existing atope o6 approxFinatety 10%. The trenches ate to be ahattow with the Rine exiting the house at app4oximatety 1 6t. betow ot.i.ginat WELLINSPECsewer •FLOW TESTTION grade due to gtoundwatet encountered at 10 6t. betow the ground suAjace. The atietnate teach6.ie.td trench wilt tegwiAe a Ri6t station to be .inatatted. SITE PIANS The ptopettiea .in the area a4e tetativety .targe and we 6o,%uee no negative .impact on adjacent ptopetties by the .inatattation o6 the proposed wett and septic system. It shou.td be noted that the southwest pottion o6 the property .is a ROAD DESIGN te.tati.ve.ty .tow, wet a4ea with amatt aptfnga draining .into an existing c4eek maintenance easement. The proposed septic .is in ex.cea6 o6 100 6t. to these apti.ngs. SOILTEST 16 you have any questions of Lequ.iAe additiona.t in6o4mation 6o4 your e contact us. i:7 PERCOLATION TEST i A. SHAFER, P.E. STRUCTURAL& MECHANICAL INSPECTIONS ONSITE WASTEWATER DISPOSAL SYSTEM DESIGN 17034 EAGLE RIVER LOOP, SUITE 204, EAGLE RIVER, ALASKA 99577 tt I SCALE I -x-- r • M1a. cf tm' Ex \sT,.tE, Wew R, rtr I� II � �s�- 4-PSS:•. - f000 Gam. /vn,y Osoce, tt 125o Gna-tic-rbr�1� c� 5 � CSF-•��t.- J Aw erwaz >jfu/l �' AvfEv-#JA"E NIL'L l,t�f Scor-! l a SrD•t.l,�floa.) 30 0 \T,5.40K- N tr i : " eta • * c N ml m r sm 0 i : " eta • * ml m r sm 0 Muof Anchorage OF ti DEPARTMENT OF t1EALTH d HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST PERFORMED FOR: Jr� �� LEGAL DESCRIPTION: L. he OE(i71PTH 1 av- FSA 2 ff V 3 1. i I''✓,uM 4,0 o, �� lel .. • 5 7 b 6- 7- 710 10 M.� 11 -9" n. 1213- 14 15 16 17 16 19 20 COMMENTS Section: SLOPE WAS GROUND WATER /i•/ ENCOUNTERED? S IF YES, AT WHAT L DEPTH? 0 P E Depth to Weter Atter Monitoring? I c:> Detr. 7 It t, qtr, A. Et?!a �cocnoil[r..41f /tiY..•TJ /+e PERCOLATION RATE (minutestinch) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND --+— FT !1 PERFORMED BY17T34 F.a:fo Rivar Loop Road Nn 104 laska ACCORDANCE W II ALL STle ATE AND MUSNICIPAL GUIOELIei 72 -ON (Rev. 4r95) �— CERTIFY THAT THIS TESTI WAS PERFORMED IN ON THIS DATE. DATE: 2�� �� lel .. • treat'— - �'�• PERCOLATION RATE (minutestinch) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND --+— FT !1 PERFORMED BY17T34 F.a:fo Rivar Loop Road Nn 104 laska ACCORDANCE W II ALL STle ATE AND MUSNICIPAL GUIOELIei 72 -ON (Rev. 4r95) �— CERTIFY THAT THIS TESTI WAS PERFORMED IN ON THIS DATE. DATE: 2�� PERFORMED LEGAL D 2- 3- 4- 7 34 t !� 9- 12- L L 12 _l___ 13- 14- 15- 16- 17- is - 1 9 3141516171819 20 COMMENTS Municipality of Anchorage DEPARTMENT OF HEALTH 6 HUMAN SERVICES r 825 `L' Street, Anchorage, Alaska 99502-0650 •/ SOILS LOG — PERCOLATION TEST YI FA 1� Township, DATE Section: 1 /� ENCOUN ERE WATER , //' 1/f ENCOUNTERED? IF YES. AT WHAT DEPTH? Depen to Wrier lino 10 i r Monitoring? - Date: .1I • f'1 osr, R..F,�l:.r • ,v. F:u twi': •i S•.�'s 1r PERCOLATION RATE 1' � (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND dl FT PERFORMED 7034 Eag1a River loop Road No. 204 E .ag a rvcrT:M77-- ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELI� 72.009 (Rev. 4/85) CERTIFY THAT THIS TEST WAS PERFORMED IN ONTHISDATE. DATE: Z — J-r-c?r iiYL--Sii7f.'3� 1r PERCOLATION RATE 1' � (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND dl FT PERFORMED 7034 Eag1a River loop Road No. 204 E .ag a rvcrT:M77-- ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELI� 72.009 (Rev. 4/85) CERTIFY THAT THIS TEST WAS PERFORMED IN ONTHISDATE. DATE: Z — J-r-c?r u56789707 rV ii � -y: ty c� G` *Akjl • • JUL t n • A Municipality of Anchorage �� 3 '� On-Site Water and Wastewater Program (907) 343-7904 O! s A F _ g`11 ' Certificate of On-Site Systems Approval Parcel I.D. 015-471-16 Expiration Date: 11 - 7- J 1. GENERAL INFORMATION Complete legal description Hideaway Lake B2 L5 Location (site address) 11101 Hideaway Lake Cir. Current Property owner(s) Lisa & James Huffman Day phone Mailing address 11101 Hideaway Lake Cir Anchorage, AK 99507 Real Estate Agent Day phone 2. TYPE OF DWELLING: ▪ Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Q Individual Individual Water Storage ❑ Holding Tank . ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received : � �� � .�:�, 1.0410,... Date: g w ` Jj U COSA to be released to the engineer,unT€ss otherwise requested by th-engine-r. COSA Fee $ • C �L3 °� Waiver Fee $ Date of Payment a g Date of Payment Receipt Number 0 0 Receipt Number COSA# 52co-0(,) Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,and regulations in effect at the time of installation. In conducting an adequacy test,I attempt to provide a thorough,conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations.The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition,ground water levels that may fluctuate during the year,and the water usage of the family being served by the system.These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system,nor do they guarantee that there are no hidden defects or encroachments.Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system.The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Phone (907) 745-8200 Address P.O. Box 1807 Palmer, AK 99645 Engineer's Printed Name Steven R Pannone Date 7/30/2018 AM'K+�G OF a.Qs k 1 6. DSD SIGNATURE • %* ••STM ./� *y System#1 Approved for L/ bedrooms Steven R. Pannone r �*- CE-8149 = System#2 Approved for bedrooms �� �f . �� Disapproved �kkV'PROFESSt4NA�'�+.� Conditional approval for bedrooms, with the following stipulations: Q`,6r\( OF f iii; � ON-SITE ,....„, G- WATER ANn r m WASTEWATER •�" %<, PROGRAM it ..".?.(,,_rn.j1r-- By: w ,- ` Original Certificate Date:�— 2- (g The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. • 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other vTcwv\[ Z'`{ yv, COSA blue sheet f •. .. If more than 1 septic system is on the lot: COSA Checklist# 1 of 1 Structure served by this system 1 Certificate of On-Site Systems Approval Checklist Legal Description: rHideaway Lake B2 L5 Parcel ID:015-471-16 A. WELL DATA �`30`7 4f Well type Private / If A, B, or C provide PWSID# Well Log (YIN) Y Date completedSanitary seal (Y/N) Y Wires properly protected (Y/N Y Total depth 103 ft. Cased to 64 ft. Casing height (above ground) lg-t in. FROM WELL LOG AT INSPECTION Date of test 08/30/94 06/21/18 Static water level 4 ft. 52.8 ft. Well production 3 4 g.p.m. 3 2 g.p.m. WATER SAMPLE RESULTS: Coliform NEG colonies/100 mL Nitrate 3.88 mg/L Arsenic ND ug/L Date of sample: 7/20/2018 Collected by: PES B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/ STEEL Date installed 06/14/94 Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank(Y/N) N High water alarm (Y/N) N/A Date of pumping 04/30/18 Pumper A+ HOME SERVICES, INC C. ABSORPTION FIELD DATA Date installed 6/14/1994 Soil ratingi z 0.6 GPD/SF WIDE TRENCH (g.p.d./ft or ft /bdrm) System type Length 50/80 ft. /�� Width 5/5 ft. Gravel below pipe 3/3 ft -CriTotal depth y ft. Eft, absorption area 1100+ft2 Monitoring tube Y Depression over field N Date of adequacy test 07/5/18 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 0/36 in. Water added 600 gal. New depth 0/38 in. Elapsed Time: 1440 min. Final fluid depth 0/36 in. Absorption rate >= 600+ g p d Any rejuvenation treatment (past 12 mo.) (Y/N &type) N If yes, give date Seyet, r D. LIFT STATION Date installed Size in gallons Manhole/Access (YIN) "Pump on" level at in. "Pump off level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? • E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100+ On adjacent lots 100+ • Absorption field on lot 100+ On adjacent lots 100+ Public sewer main 75+ Public sewer manhole/cleanout 100+ Sewer/septic service line 25+ Holding tank 100+ Animal containment areas 50+ Manure/animal excrete storage areas 100+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 10+ Property line 10+ Absorption field 5+ Water main 10+ Water service line 10+ Surface water 100+ Wells on adjacent lots 100+ ABSORPTION FIELD ON LOT TO: Property line 10+ Building foundation 1 0+ Water main 10+ Water Service line 10+ Surface water 100+ Driveway, parking/vehicle storage 10+ Curtain drain 50+ Wells on adjacent lots 100+ F. COMMENTS Survey on file./f. NIL-.G/ el.,s `f-G�L:,/tt�L Lower field is inundated with liquid / installed proper flowsplitter G. ENGINEER'S CERTIFICATION r~��"`L ��OF A��s11 I certify that I have determined through field inspections and �''"4P• Ar �t review of Municipal records that the above systems are in 0*: •• TH �/\ *y conformance with MOA COSA guidelines in effect on this date. •••• •• �OW Steven Pannone � e"----- Steven Printed Name •Steven R. Pannone • y Date 07/30/2018 ���c-�,. CE-8149 i/ i���� A\X k oFEsst COSA canary sheet_2-6-15.doc I (44 1 U >> c. ( ' a / ( q‘. 'i \Pc, c) 1-T .. '16 • . ---• ..1 C Iii 15t)---7 \C N $ 4...:1roi & 1t E / i '''. i- , ,-- ,t7 . 'r4.3.X t(...7.5C.-:::(1“ Lit -I '''S-(9.. : 1- . . -. ;°L }(ct.z:sd cam• -- Z. 0,\ I, N Pannone Engineering Service, LLC JOB TITLE dP(i' 0. __ P.O. Box 102954 SUBJEC , Anchorage AK 99510 O7 /1 --- —_____.. Phone 907-272-8218 • FAX 907-272-8211 - . . �-•►tet=HECKED DATE� 'SHEET OF Ecklund, Timothy J From: Steve Pannone <Steve@panengak.com> Sent: Monday, August 6, 2018 4:25 PM To: Ecklund, Timothy J Cc: jameshuffman65@gci.net Subject: RE: Hideaway lake blk 2 lot 5 Attachments: doc04035520180806153058.pdf Tim, I reviewed my technicians notes in detail, and developed the attached sketch showing the depths of cover over the pipe. It appears that the last 20 feet of the upper trench has less than the required cover. However, there is sufficient length of the remaining 110 If of drainfield that has sufficient cover to adequately absorb the expected daily flow. Additionally, the owner has indicated that he has not had any issues with the system freezing since he has owned this property. Therefore, I request you approve the system as installed. Steven R. Pannone, P.E. Pannone Engineering Services, LLC 907.227.3522 Cell 907.745-8200 Office 907.745-8201 fax Please Check Out the NEW www.panengak.com Agents/Clients can order tests online, check status and email staff PES give our Active Military/retired Vets a 5% discount on Engineering services. MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT � • F r\`, 907-343-7904 On-Site Water and Wastewater Section Fax: 343-7997 www.muni.org/onsite \ __.: Septic Septic Tank Advisory Certificate of On-Site Systems Approval # OSC181382 Subdivision: Hideaway Lake Block:2, Lot: 5 The septic tank for this property is 24 years old. The average life for a steel septic tank is 20 years. Typical replacement costs range from $6,000 to $9,000. This advisory must be attached to all copies of the subject Certificate of On-Site Systems Approval. This is an example of what the metal of a 20 year old steel tank MAY look like. , AV" --. s.,1, ,,:4-0,. 40.., - kv ;;--:-i --,-: lir , ...i.t.e.., ......t. :� asc' 3a ,a 77 X91 r w -A.: s .s g ' , ,rd- ' ' . ' -4 4 4,:•`• ;?....,,-)4 \ 5.e - ' la \, • e'er . `Y '' °y. '4,0>.f -- ((ii.« 0*.-22 ryi Mailing Address:P.0.Box 196650*Anchorage,Alaska 99519-6650 *www.muni.org Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Street 1 P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL *9`11sh!i FOR A SINGLE FAMILY DWELLING Parcel l.D._00S'-4?(—I (c COSA# 0902AC Expiration Date: GENERAL INFORMATION Complete legal descripti Location (site address) Current Property owner( Mailing address Lending agency Day phone p 4 l S �• Real Estate Agent *9`11sh!i FOR A SINGLE FAMILY DWELLING Parcel l.D._00S'-4?(—I (c COSA# 0902AC Expiration Date: GENERAL INFORMATION Complete legal descripti Location (site address) Current Property owner( Mailing address Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well $1 Individual On-site Individual Water Storage �❑ Individual Holding Tank Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Address Engineer's Printed Name 5. DSD SIGNATURE Approved for bedrooms. Disapproved. Phone ru cu/I Date -7/19,/017 MICHAEL N. ANDERSON Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other By:6 _e Original Certificate Date: 7— o` 3' (Ra. 11105) Municipality of Anchorage Development Services Department Building Safety Division �— On -Site Water & Wastewater Program. 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: I d taw0y t-0 Ar .1 Q 'Z- L Parcel ID: O rS -t47t -f (0 A. WELL DATA Well type -PL-t If A. B, or C provide PWSID ft L Well Log (Y/N) Date completed'Sanitary seal (Y/N) Wires properly protected (Y/N) Total depth f l) ft. Cased to &r�ft. Casing height (above ground) in. FROM WELL LOG AT INSPE TION Date of test 7 O Static water level ft. �% ft. Well production g.p.m. ?7.'7r g.p.m. WATER SAMPLE RESULTS: Coliform JPcolonies/100 mL Nitrate I mg/L Other bacteriacolonies/100 mL Arsenic: ug/L date of sample: Q �, Collected by: k h rA B. SEPTICIHO DING TANK DATA Tank Type/Material 4 Date installed Tank size ZSD 'gal. Number of Compartments Z- Cleanouts (Y/N) ' Foundation cleanout (YIN) Depression over tank (Y/N)',/High water alarm (Y/N) Date of pumping 7 Pumpert �uu C. ABSORPTION FIELD DATA Date installed Soil rating (g.p.d.If? or ft2/bdrm) D Lo_ System typer7�c C 40 ewG► Length I e? V ft. Width S.O ft. Gravel below pipe7i��� ft. Total depth ft. Eff. absorption area r00'ft= Monitoring tube Y Depression over field N Date of adequacy, test ! 0 Results (Pass/Faiq 0%. 4 y For � bedroo s rr Y Fluid depth in absorption field before test n� Water added g New depth � in. rr Elapsed Time: M Amin. Final fluid depth Absorption rate >= 600-i- g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) �� If yes, give date D. LIFT STATION Date installed Size in gallons 'Pump on' level at _ in. 'Pump off" 1 Datum Cycles tested. E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankAR station on lot lip 0 J - Absorption field on lot tot) Q Public sewer main Sewer/septic service line /o0rZe- Animal containment areas 100) r14 High water alarm level at Meets alar & circuit requirements? In. On adjacent lots (uV f f On adjacent lots C D 6 r (- Public sewer manhole/cleanout Holding tank Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HetOING TANK ON LOT TO: S r Building foundation Z� /� Property line l=z4- Absorptiorrfield---�� aipr f Water main t� _ Pr service me .� Surface water / C� d r'f- V , latent lots f Od ''f' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: w� Property line �0 f Building foundation (� Water main /' Water Service line S'D Surface water /B b /f Driveway, parking/vehicle storage ' Z-0 Curtain drain too 11 4 Wells on adjacent lots 100'4- F. COMMENTS O At 1 G. ENGINEERS CERTIFICATION I certify that I have determined through field inspections and �; ; 49?H•••'•. k / review of Municipal records that the above systems are in �....... —/�j � conformance with MOA COSA guidelines in effect on this date. ',1.. � Engineer's Printed Name /`fr >m ���n� 6wf �/ c�.eva+AE4N,'ANocescNCE- 46 Date % IK/w!t COSA Fee p Waiver Fee $ Date of Payment 0 "I Date of Payment Receipt Number Receipt Number (Rev. 11/05) N 69°5924"W 1 15.96' SCS ReLM 1093390001 Client Name Mike N. Anderson, P.E. Project Name/M Roger Augdahl Client Sample 11) 11101 1lideaway Lake Circle Matria Drinking Water PWSID 0 Sample Remarks Printed Datelrime Collected Datefrime Received Date/rime Technical Director 07/16/2009 16:10 07/13/2009 8:00 07/13/2009 9:00 Stephen C. Ede Allowable Prep Analysis Parameter Results POL Units Medal Container ID Limits Date Date [nit Metals by ICP/MS Arsenic ND 5.00 ug/L EP200.8 C (<10) 07/13/09 07/15/09 NRB Waters Department Total NitratefNittite-N 4.40 0.100 Microbiology Laboratory Colony Count 0 Total Coliform 0 Fecal Colifurm 0 mgfL SM204500NO3-F B (<10) col/100ml- SN1209222B col/100mL SM209222B col/100mL SM209222B A (<200) A (<I) A (<I) 07/13/09 LCE 07/13/09 DLC 07/13/09 DLC 07/13/09 DLC