ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: sw090147 PID Number: 041-022-39
Name: Timothy Schwanke & Patti Ruppert Wastewater System: [] New [] Upgrade
Address:
2164 Arcadia Drive Anchorage, AK 99517 ABSORPTION FIELD
Phone: Number of Bedrooms:
632-8684 4 [] Deep Trench I~ Shallow Trench [] Bed [] Mound [] Other:
Soil Rating: Total Depth from original grade:
LEGAL DESCRIPTION 1.2 GPD/Ft2 6 Ft.
Block: 1 Lot: 1 Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe:
Tuxedni Park West 2 Ft. 4 Ft.
Township: Range: Section: Fill added above original grade: Gravel Length:
2 Ft. 50 Ft.
Well: [] New [] Upgrade Gravel width: Number of lines: eist .... between lines:
5 Ft. I Ft.
Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material:
Private 81 Ft. i 81 Ft. 500 Ft2 ASTM D3034 PVC
Driller: Date Drilled: Static Water Level: Installer: Date Installed:
Alpine Drilling 10/28/09 25 Ft. Red Dog Excavating 10/15-18/09
Yield: 10 GPM Pump Set at:76 Ft. Casing Height>2Above Ground:Ft. TANK
SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other:
T~ To Septic Absorption Lift Holding )ublic/Private Manufacturer: Capacity:
Fror.%
Tank Field Station Tank Sewer Line Anchorage Tank 1,250 Gal.
Material: Number of Compartments:
Well >1 Off > 100' N/A N/A >25' Steel Two (2)
Su,aceWater >100' >100' N/A N/A % / LIFT STATION
Size: Manufacturer:
Lot Line >5' > 10' N/A N/A Gal.
"Pump on" level at: "Pump off" level at: in. High water alarm at:
Foundation >5' >10' N/A N/A in. in.
Pump Make & Model Electrical Inspections performed by:
Curtain Drain Nor~e Noted
Remarks: BENCH MARK
Location and Description:
Garage Slab
Assumed Elevation:
100.0
Inspections performed by: A. Harala Dates: 1et 10/16/2009 ~ e- O~ ,d,/ . ~
2® 10/17/2009 ~'cO"~"~*"
Development Services Department Approval ,,'.:' 49T_B~
,.~.,~....~ .....
Conditional Approval Date: ~ '7'~l~
· CE-4as
Reviewed and approved by: t/~- ) ate: ] 0 "/' / 0 t~.
0
Z
Z
LLJ
X
3AIUO U319931¥
,00'0~ ~,,0~2,~0.00 N
W
C)
7
Q
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number: SW090147
Page 3 of 3
PID No. 041-022-39
84.95 ' ·
Finished Grade
Original Ground
88.9
,/86.5
Geotextile Fabdc
Drainfield Rock
78.0
80.8.--2
53' (Trench Length)
74.5
No Groundwater
84.9
PROFILE AS-BUILT
No Scale
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
MEMORANDUM
DATE:
October 1, 2010
TO:
Jeff Poet
FROM:
Mike Anderson, P.E.
SUBJECT:
Lot 1, Block 1, Tuxedni Park West Subdivision
Septic System Inspection Report
COSA
The area for the septic system absorption trench was leveled prior to construction. In
addition, the house was moved approximately 15' to the southwest. The orientation of
the absorption trenches was different from the original design due to the leveling of the
area and the movement of the house. Placement of the trench in the alignment shown
on the inspection report resulted in the effective area of the trench entirely in the
percolation zone. The trench was also placed parallel with the contours of the ground
surface.
~l~p /_/ IU U~.q-/~ I IIH[)~! DU~51i'I L.~UH~SLIUGLIUH ~gLJ I-O;~/--I--O/O/
Mark Begich
Mayor
Development Services Deportment
Building 5(~fety Division
On-Site Water & Wastewater Program
4700 Elmore Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.or0/o n$i-I'¢
(907) 343-'7904
Pump Installation Log
Well Drilling Permit Number: SW
Date of Issue:
Parcel Identification Number:
Replacement Only: YES NO
Legal Description
Lot I, Block L Tuxedni Park West
II P
roperty Owner Name & Address:
I Timber Basin Construction
I PO Box 772461
I Ea~le River, ~4IC 99577
Pump Installation Date: 4/14/2010
Pump Intake Depth Below Top of Well Casing: 76 feet
Pump Manufacturer's Name: Grundfos
Pump Model: 15SQE07-J80
Pump Size . 75 hp
Pitless Adapter Burial Depth: 12 feet
Pitless Adapter Manufacturer's Name: Campbel
Pitless Adapter Installer: Unknown
Well Disinfected Upon Completion? [] Yes [] No
Method of Disinfection: Recirc
Comments:
Pump Installer Name:
.~arow Pump & Welt Service LLC
PO Box l10496,Anchorage, AK. 99511
(907) 346- 9355
Attention: The 0umo installer shall nrovlde, a n.mn inq~allafi~n ln~r tn th~ UIRI~ ..,;~h;.. ~A W ..... ~' ..... ;.~.~1~..;~
Alpine Drilling & Enter'prises
Well Log
Permit Number: #SW090147 Date of Issue: 8-13-09 Parcel Identification Number: 04'1-022-39
Date Started: 10-27-09 Date Completed: 70-28-09 Is well Iocated at approved permit location? x Yes [] No
Legal Description: Tuxedni P~k West Block I Lot I
Property Owner Name & Address: Timothy Schwanke & Patti Rupe
2~64 Arcadia Drive
~ Anchorage, Alaska 99523
Borebole Data: Depth (ft)
Soil Type, Thickness & Water Strma From To
Stick-up 0 2
Sand), silt 2 I!
Gravelly. silt 11 29
sand9' ilt 19 26
gravelly silt 26 59
~zdy gravelly silt 59 77
~'ater sand & gravel 77 8]
Method of Drilling x air rotary [] cable tool
Casing type: steel
Wall Thickness: .2__~5 inches
Diameter: 6 inches Depth: 8__~J feet
Liner Type: ~
Diameter: ~ inches Depth: ~ feet
Casing stickup above ground: 2 feet
Static water level (from ground level): 2_~_5 feet
Pumping level: 81 feet after
2 hours pumping 10 gpm
Recovery Rate: ]__0_0 gpm
Method of Testing: .air
Well Intake Opening Type:
x Open End [] Open Hole
[] Screened Start.. feet Stopped~
[] Perforations Start~ feet Stopped
feet
feet
Grout Type: bentonite granules
Start 0 feet
Pump: Intake Depth,, feet
Pump size hp Brand Name
Volume: ] bg
Stopped ? feet
Well Disinfected Upon Completion? x Yes [] No
Method of Disinfection: chlorine tablets
Comments:
Well Driller:
Alpine Drilling & Enterprises
PO Box ] 10496
Anchorage ,4Jq 9951]
&700
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
BRAGAW STREET ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: LOT I, BLOCK I, TUXEDNI PARK WEST
PERFORMED FOR: TIMBER BASIN CONSTRUCTION
DATE: 10/16/2009 PROJECT No.:
PARCEL ID#: TECHNICIAN: A. HARALA
DEPT~ TEST HOLE 3
(feet)
OB/OG
i
2
3 SILTY SAND
WITH GRAVEL
4 sN
5
6 B0H @ 6'
TRENCH SIDE WALL
7
8
9
SLOPE
SITE PLAN
SEE SITE PLAN
11
13--
20--
WAS GROUND WATER ENCOUN'I~RED? No
IF YES ~ WHAT DEPTH? ~
DEPTH OF WATER AFTER MONITORING:
DATE OF MONITORING:
DEPTH TO
DATE READING GROSS TIME NET TINE WATER NET DROP
(HINUTES) (HINUTES) (INCHES) (INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
10/16 1 9:04/9:14 10 3.63"/7.00" 3.37"
2 9:15/9:25 10 3.50"/6.75" 3.25"
3 9:26/9:36 10 3.56"/6.75" 3.19"
4 9:37/9:47 10 3.50"/6.75" 3.25"
5 9:48/9:58 10 3.63"/6.91" 3.28"
6 lO:OO/lO:1O 10 3.50"/6.75" 3.25"
PERCOLATION RATE:3.1 (MIN/INCH) PERC. HOLEDIA. 6" .(rNC~rES)
TEST RUN BETWEEN: 6.0 FT. and 7.0 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 10/I/2010
MUNICIPALITY OF ANCHORAGE
}
Development Services Department / Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Parcel I.D. 041-022-39
Certificate of On -Site Systems Approval
Expiration Date: _ 11-2- G -Z 692 0
1. GENERAL INFORMATION
Complete legal description TUXEDNI PARK WEST BLK 1 LT 1
Location (site address) 9400 ATELIER DR, ANCH AK
Current property owner(s)
Mailing address
Real estate agent
TIMOTHY SCHWANKE & PATTI RUPPERT
SAME
2. TYPE OF DWELLING:
0 Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 4
Day phone
Day phone
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
El
Private Septic
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ to60 C.O\j 1 b - 1 '�
Date of Payment
W-25�-Zv
Receipt Number MSO Zl
COSA4 OS C aO 1 y 55
Waiver Fee $
Date of Payment
Receipt Number
Waiver 4
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted.
Name of Firm MIKE N ANDERSON, P.E. Phone 727-8864
Address 4661 NATRONA AVE ANCH AK
Engineer's Printed Name MIKE N ANDERSON, P.E.
6. DSD SIGNATURE
System #1 Approved for 4
System #2 Approved for
Disapproved
Conditional approval for
bedrooms
bedrooms
Date 8-15-20
OF. At 1
% :497TH
yo • l� MICHAEL N. ANDERSON :0C CE- 46 • `�"o
bedrooms, with the following stipulations:
r2 WASTEWATER >
Jm PROGR -
FRV�G �—
B f Original Certificate Date:,T— Z % —z0z 0
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checkfist blue sheet
COSA Checklist
Legal Description: TUXEDNI PARK WEST BLK 1 LT 1
If more than 1 septic system on lot: COSA Checklist # of
A. WELL DATA
FEI Well log is filed with Onsite (or attached)
Date drilled ......09
Total depth 81 ft
Cased to 81 ft
A Sanitary seal is functioning correctly
F01 Wires are properly protected
Casing height (above ground) 25+ in.
Date of flow test for COSA 8112/20
Static water level at beginning of test 24 ft.
Comments
B. TANK DATA
Age of tank(s) 1 years
Tank type/material
Measured operating fluid level in septic tank 48"
■❑ Standpipes/foundation cleanout per record drawing
Date of pumping L 'Z a Z 0
D. ABSORPTION FIELD DATA
Which system tested (date installed) 10/17/09
Q ALL standpipes present per record drawing
Total measured depth from grade 6.1 ft (max)
Measured depth to pipe invert from grade 2.1 ft (min)
❑ N/A — pressurized field
F Monitor tubes go to bottom of effective. If not, state
depth into effective
❑ Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced 0 gallons
Comments/Deficiencies:
COSA Checklist yellow sheet
Parcel ID: 041-022-39
Structure served by this system
Well production at time of test 5+ gpm
Water storage tank volume 0 gallons
Well disinfected for coliform test? ❑ Yes 0 Nc
7 Coliform bacteria is Negative
Nitrate 2.71 mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L97 Arsenic less than MRL (ND)
Collected by MNA
Date of Sample 8112/20
C. LIFT STATION
❑ Required maintenance completed
Age of lift station years
Lift station material
Comments:
Adequacy test date 8/12/20
Results ❑✓ Pass For 4 bedrooms
Fluid depth prior to test 1 in
Water added 600+ gal
New depth 3 in
Elapsed time 1440 min
Final fluid depth 1 in
Absorption rate 600+ and
Any rejuvenation treatment (past 12 months)
If yes, enter date
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
[�✓ Yes
Neighboring Tank > 100' 0 Yes
Absorption Field on Lot? 100' M✓ Yes
if No
if No
if No
ft[✓
ft
ft
Community Sewer Manhole/Cleanout > 100'
Yes if No
Private Sewer/Septic Line > 25'[]✓ Yes if No
Holding Tank > 100'C7✓ Yes if No
ft
ft
ft
Neighboring Absorption Fields > 100'
El Yes
if No
ft
Animal Containment > 50' Q Yes if No
—
ft
Community Sewer Main > 75' 0Yes
if No
ft
Manure/Animal Excreta Storage > 100'
M Yes if No
ft
From Septic/Holding Tank on Lot to:
(Please enter
distances if less than required)
Building Foundations > 10' Q Yes
Property Line > 5' [j Yes
if No
if No
ft
ft
Surface Water > 100' ❑Yes if No
Wells on Adjacent Lots:
ft
Absorption Field > 5' Yes
Water Main > 10' []✓ Yes
Water Service Line > 10' [D Yes
if No
if No
if No
ft
ft
ft
Private Wells >' 100
_ (�✓ Yes if No
Community Wells :200' Yes if No
if septic tank is under driveway comment below
ft
ft
From Absorption Field on Lot to: (Please enter distances if less
than required)
Building Foundation > 10' Q✓ Yes
Property Line > 10' r"7 Yes
if No
if No
ft
ft
if absorption field is under driveway comment below
Wells on Adjacent Lots:
Water Main > 10'✓[] Yes
Water Service Line > 10'[]r Yes
Surface Water > 100' [✓ Yes
if No
if No
if No
ft
ft
ft
Private Wells > 100' Yes if No
CommunityWells >
_ 200' 0✓ Yes if No
ft
ft
F. ENGINEER'S COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that 1 have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
COSA Checklist yellow sheet
T
74 • MICHAEL N. ANDERSON •;
C J446
l ikd'-.� OFESSIO���-•:`
toes.
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
~ ~ P.O. Box 196650 r .
~ www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 041-022-39
GENERAL INFORMATION
Complete legal description
Expiration Date: /-' / - / /
Lot 1, Block 1, Tuxedni Park West Subdivision
Location (site address) 9400 Atleier Drive Anchorage, AK
Current Property owner(s) Timothy Schwanke & Patti Ruppert
Mailing address 2164 Arcadia Ddve Anchorage, AK 99517
Day phone
Lending agency
Mailing address
Real Estate Agent
Day phone
Day phone
Mailing Address'
Unless otherwise requested, COSA will be held by DSD for pickup.
NUMBER OF BEDROOMS: Four (4)
TYPE OF WATER SUPPLY:
Individual Well []
Individual Water Storage []
Community Class ~ Well []
Public Water System []
TYPE OF WASTEWATER DISPOSAL:
Individual On-site []
Individual Holding Tank []
Community On-site []
Public Sewer []
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure ihdicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and insp~.~O~, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable MuAi~L~cJ. State codes,
., Ordinances, and regulations in effect at the time of installation.
~Name of Firm Anderson Engineering Phone 522-7773
Address P.O. Box 240773 Anchorage, AK 99524
Engineer's Printed Name
Michael E. Anderson, P.E.
DSD SIGNATURE
~ Approved for J-~ bedrooms.
Disapproved.
Date 10/1/2010
Conditional approval for
bedrooms, with the following stipulations:
Attachments:
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
X
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
/~~Z'-Original Certificate Date: ,/C'O '-~/- / ~
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650 ' -
Anchorage, AK 99519-6650
www. muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description:
A. WELL DATA
Well type Private
Date completed 10/2~09
Total depth 81
Lot 1, Block 1, Tuxedni~ Park West Subdivision
If A, B, or C provide PWSID #
Sanitary seal (Y/N) Y
it. Cased to 81 it.
FROM WELL LOG
Date of test 10/28/2009
Static water level 25
Well production 10
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 mL
Arsenic: N/D mg/I
B. SEPTI~,/HOLDING TANK,'DATA
Tank Type/Matedal Septic/Steel
": y~kSize 1.250 ga]. -
Fo'd~dati0n clean')ut ~/N) Y
g.p.m.
Nitrate 1.9o mg/L
Date of sample: 9/23/10
Number of Compartments Two
Depression over tank (Y/N)
Date of pumpi.ng New .Construc~n Pumper N/A
ABSORPTiON FIELD DATA
Date installed 10/16-17/09
Length 50 it.
Total depth 8-8.5 it.
Parcel ID: 041-022-39
Well Log (Y/N)
Wires properly protected (Y/N)
Casing height (above ground)
AT INSPECTION
Y
g.p.m.
Other bacteria o colonies/100 mL
Collected by: A. Harala
Soil rating (g.p.d./ff2 or ff~/bdrm) 1.2 GPD/SF
Width S ft.
Eft. absorption area 500 ft2 Monitoring tube
Date of adequacy test New Const. Results (Pass/Fail) __
Fluid depth in absorption field before test in. Water added
Elapsed Time: min. "Finalfluid ~depth
Any rejuvenation treatment (past 12 mo.) (Y/N & type)
System type 5' Wide Trench
Gravel below pipe 4 ft.
Y Depression over field N
For bedrooms.
gal. New depth in.
in. Absorption rate >=
N If yes, give date
Y
>24 in.
Date installed 10/15/2009
Cleanouts (Y/N) Y
N High water alarm (Y/N) N
LIFT STATION
Date installed
"Pump on' level at
Datum
in.
E. SEPARATION DISTANCES
Size in gallons
"Pump off" level at~
Cycles tested
in.
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot ' >lOO'
Absorption field on lot >100'
Public sewer main N/A
Sewer/septic service line >25'
Manhole/Access (Y/N)
High water alarm level at
Meets alarm & circuit requirements?
-in.
On adjacent lots >1oo'
On adjacent lots >1oo'
Public sewer manhole/cleanout
Holding tank N/A
N/A
Animal containment areas >50' Manure/animal excrete storage areas
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >5' Property line >5' Absorption field >5'
Water main N/A Water service line >10' Surface water >lOO'
Wells.on adjacent lots >lOO'
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line >1o' Building foundation >1o'
Water Service line >1o' Surface water >1oo'
Curtain drain None Noted Wells on adjacent lots >1oo'
COMMENTS:
>100'
Water main >1o'
Driveway, parking/vehicle storage >25'
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Michael E. Anderson, P.E,
Date lO/1/2OlO
COSA Fee $
v
Date of Payment
Receipt Number
(Rev. 11105)
Waiver Fee $
Date of Payment
Receipt Number
0
0
z
N 00°03'30"W 40.00'
AT£LLIER DRIVE
N 00°00' 18"W 363.13'
-.-I
C
X
r'r'l
Z
~0~2
C
Z
C
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT
Initial
Date Issued: Aug 13, 2009
Expiration Date: Aug 13, 2010
Permit Number: SW090147
Legal Description: TUXEDNI PARK WEST BLOCK 1 LOT 1
Design Engineer: 0014 ANDERSON ENGINEERING
Owner Name: TIMOTHY SCHWANKE & PATTI RUPPE
Owner Address: 2164 ARCADIA DRIVE
ANCHORAGE, A 99523-
Parcel ID: 041-022-39
Site Address: 9400 ATELIER DRIVE
Lot Size: 198651 SQ. FT.
Total Bedrooms: 0 Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. Ail requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, Alaska 99519-6650
www.muni.org/onsite
(907) 343-7904
ON-SITE SEWER/VVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 041-022-39
Property owner(s) Timothy Schwanke & Pa~ Ruppert
Mailing address 2164 Arcadia Drive Anchorage, AK 99517
Site address 9400 Atelier Drive Anchorage, AK
.Day phone 632-8684
.Zip Code 99523
Zip Code
Legal description (Sub'd., Block & Lot) Lot 1, Block 1, Tuxedni Park West Subdivision
Legal description (Township, Range & Section)
Lot Size 198,651 Sq. Ft. Number of Bedrooms Four (4)
THIS APPLICATION IS FOR (~] all that apply): THIS APPLICATION IS AN:
Absorption Field E] Initial
Septic Tank [] Upgrade
Holding Tank [] Renewal
Pdvy []
Pdvate Well []
Water Storage []
[]
[]
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 7 '~ ~} Waiver Fees:
Date of Payment: (~' ' ~/~ - O ¢7 Date of Payment:
Receipt Number. ~) q '70 ~ ~ Receipt Number:.
(Rev. 11/05)
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
August 3, 2009
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
Lot 1, Block 1, Tuxedni Park West Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 1, Block 1, Tuxedni Park West Subdivision intends to construct a new
four-bedroom home on the lot. We are therefore requesting a permit be issued for the
construction of a new well and septic system to accommodate the home. The attached
Site Plan and backup documentation identify the location and configuration of the
proposed well and septic system along with the alternate site. Also identified on the
plans are the existing wells and septic systems on surrounding lots. No conflicts exist
between the proposed well and septic system and wells or septic systems on adjacent
lots. Drainage arrows are shown on the site plan showing the grade and direction of
flow on the lot. The drainage pattern will not be changed as a result of this project.
The test holes placed on the lot in the area of the absorption trench and alternate site
indicate clean poorly graded sand with some silt (SM/SP). The percolation rate of the
soil was determined to be 3.1 minutes per inch. No groundwater was found during the
placement of the test holes and none was noted during the monitoring period. An
application rate of 1.2 gallons per day per square foot was used in the design of the
absorption system. We are proposing to place a new 1,250-gallon septic tank and a 50'
long by 5' wide by 4' effective depth absorption trench to treat and dispose of the
effluent generated in the house. The elevation of the distribution line in the absorption
trench wile be 4' below the surface and the total depth will be 8'. A minimum of 3' of fill
or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the
septic tank.
The ground surface on the lot in the area of the septic system slopes to the northwest.
The new trench will be constructed parallel with the contours of the slope as much as
possible in conformance with Municipal requirements. The new septic system will be
Lot 1, Block 1, Tuxedni Park West Subdivision
August 3, 2009
Page Two
constructed a minimum of 100' from all wells and any surface water and 10' the
proposed and existing water services in the area.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P,E.
Attachments
7
0
n
m
(2)
.O0'Ol, N
Z
.['&'~9~2 /~91.00,.00 N
LOT 1, BLOCK 1, TUXEDNI PARK WEST SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Four Bedroom Home 5' W~de Trench System
Pero. Rate: 1-5 MinJInch 1,250 Gatlon Septic Tank
Application Rate: 1.2 GPD/SF 4' Drainfield Rock
4 Bedrooms X 150 GPD/1.0 GPD/SF (Application Rate) = 500 SF Absorption Area
500 SF/5 SF/LF".5 (Red. Factor) = 50 LF Trench Length
THEREFORE: Construct a 50' Long x 5' Wide x 4' Effective Depth Absorption Trench at the Location
Shown. Flow Line Elevation in Trench to be 4' Below Odginal Ground Surface. Total Depth to be
8' Betow Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption
Trench. Maintain 100' Separation from Wells in the Area.
Natural
Backfill
Geotextile
-- Fabric
4" Perforated
PVC (Holes Down)
Drainfield Rock
TYPICAL 5' WIDE TRENCH SECTION
(NO SCALE} ~,~.,~,~ .........
NOTE' Grade Area Over Trench to Drain Away ;'~/ ,~th ~ "~'~
Minimum 6' Separation From Bedrock. ~....~-...f.-..,//....~[-,/~.-..:~...:~
Minimum 4' Separation From Groundwater. ~ ./.~.J.~....C~..~
Minimum 100' Separation From Wells in the Area. ~i~' ~,,c~ ~.~'~'".'.-"~
· Minimum 100' Separation From Surface Water or Streams. · ~,,'-.. No.
,o;~.~....~;~
4-
5-
6-
10-
11-
13-
14-
15-
16-
'17-
18-
2O-
' COMMENTS
Performed For.
Municipality of Anchorage
· Development Services Department
Building Safety D/vision
On-SEe Water and Wastewater Program
· 4700 South Bragaw
P.O. Bax 195650 Anchorage, AK 99519-6650
w'~w. cl. s qcho~ O~ ~ ~. ~1~
(907) 343-79O4
Soils Log - Percolation Test
WAS GROUND WATER /
ENCOUNTERED?
$
IF YES, AT WHAT DEPTH? ,~'
L
Depth to Water ARer
Reading Date Grass T~ne Net Ttrne ~ Depth to Water Net Drop
PERCOLATION RATE ~ tm~utea/.'mh) PERC HOLE DIAMETER
PERFORMED BY: ~,~ · - I · CERTIFY THAT THIS TEST WAS
PERFORM. D tN ACCORDANCE WITH ALL STATE AND MUNICIPAL'GUIDELINES tN EFFECT ON THIS DATE. DATE:
Performed For:
7-
8-
9-
10-
11-
12-
13-
14-
15-
16-
17-
18-
19-
20-
· COMMENTS
Municipality of Anchorage
~evelopment Services Department
Building Safety DMsion
On-Site Water and Waslewaler Program
' 4700 South Bragaw St.
P.O. Box 195650 Anchorage, AK g951g-6650
www.~f an;homqe ek.u[~
(907) 343-7904
Soils Log - Percolation Test
B~/,~. ~ ~-m~,w~J
Date Perfon'ned: '1/-4.-¢:) 1 ¢:>~
Toy?ship, Range, Section:.
t'
Sile Plan
WAS GROUND WATER II
H
ENCOUNTERED?
/F YES, AT V~IAT DEPTH? ~'~ t
to Water After ~
Depth
Monitoring? ~ E
D a~" :".~l~.~.~ ,.~
Reading Date Gross Time Net Time Depth Io Waler Net Drop
PERCOLATION RATE "'~, I {.~.~h) PERC HOLE DIAMETER ~'~
TEST RUN ,ETWEEN~FT 'AND C~'~
PERFORMED BY: ~ · I , CERTIFY'THATTHISTESTWA$
PERFORMED IN ACCORDANCE WrTH ALL STATE AND MUNICIPAL'GUIDELINES IN EFFECT ON THIS DATE. DATE:
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT t, BLOCK 1, TUXEDNI PARK WEST SUBDIVISION
GENERAL:
The scope of this project includes the procurement and placement of a new
1,250-gallon septic tank at the location shown on the Site Plan. Work also
includes the construction of a new 50' long X 5' wide X 4' effective depth
absorption trench at the location also shown on the Site Plan. The
distribution line in the trench will be placed at 4' below the existing ground
surface. Total depth of the trench will be 8' below the existing ground
surface. The new absorption trench and septic tank must be placed a
minimum of 100' from all private wells and any surface water in the area and
10' from the water service line proposed for the lot. A minimum of 3' of cover
is required over the absorption trench and 4' of cover over the septic tank.
Construction shall be in accordance with the approved site plan, design
drawings, Municipal Permit with any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal Regulations.
The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the location
of all lot lines. The Contractor must also verify the location of wells in the
area and assure that the separation distances are met.
Unless specifically agreed otherwise, the contractor shall be responsible for
final grading areas subsequently depressed from soil settling. Property
owner shall be responsible for revegetation of affected areas unless
specifically agreed otherwise.
Contractors installing wastewater disposal systems must be certified by the
Municipal Department of Health and Human Services for system installations.
Owners installing their own systems must receive prior approval from
D.H.H.S. before beginning system installation.
SEPTIC TANK INSTALLATION
1. A new 1,250-gallon septic tank must be procured from an approved source
and installed at the location shown.
2. A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" cleanouts for pumping access.
Lot 1, Block 1, Tuxedni Park West
August 3, 2009
Page 2 of 3
3. The septic tank shall be sufficiently bedded to prevent settling or shifting of
the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches above
final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial
insulation.
6. A foundation cleanout shall be installed one to four feet from the building
foundation. Two cleanouts are required between the tank and the drainfield.
7. Final grading over the tank shall be such that a positive slope exists away
from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the design.
The bottom of the trench shall be within 2" of level.
Distribution piping must be placed level with perforations down atop a level
bed of drainfield rock. Rock should then be placed over the pipe to provide a
minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield rock
and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations shown on
the design. The portion below the distribution line must be perforated.
Contractor shall verify the septic tank and drainfield are a minimum 100' away
from any private water wells in the area, 150' from a Class "C" Well or 200'
from any community well.
Direct bury insulation must be placed over the distribution system if less than
3' of backfill depth is available. Finish grade over the trench must be
mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
A minimum 2' of accepting soil is required below the drainfield rock for a 5'
wide trench. Contractor shall verify this condition prior to placement of the
rock. Ail pockets of unacceptable materials must be removed and replaced.
Lot 1, Block 1, Tuxedni Park West
August 3, 2009
Page 3 of 3
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic tank
manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and
solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662
or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow
Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the
#200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These inspections
must be conducted under the supervision of a professional engineer registered
in the State of Alaska. The first inspection must be conducted after the
excavation of trenches, beds or pits and before the installation of any gravel. A
septic tank may be set in place, but may not be backfilled.
The second inspection must be conducted after the placement of the geotextile
fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No
backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction notes
for use in preparing the certified as-built of the completed system.