Loading...
HomeMy WebLinkAboutMEADOW RIDGE ESTATES NORTH ADD BLK 5 LT 5Meadow Ridge Estates North Addition Block 5 Lot 5 #051-531-13 Municipality of Anchorage Page 1 of 3 Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.cLanchorage.ak.m (907) 343.7904 ONSITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SWO40377 PID Number. 051.531-13 Wastewater System: New MMBM Contracting,Inc. P.O. Box 670495 Chu lak AK 99567 ABSORPTION FIELD phona N oio1BiOowni 5'WideTrench 688.1236 Four 4 So+ rtaMV. Tar Dept tnxn or9nei vde. LEGAL DESCRIPTION 1.2 GPWFe 7 Ft. 11 ac L'AC Depth b We Comm canon" P•os. fres depdt .uatn ,,peB�aNnvr 5 5 Meadow Rid a Estates No. 5 3 Ft. 4 FL TO.WV Range 1.2 Grewt L•ngn 50 Ft. Ft. evN aWet NF r Ines O�rrtp Oata�an Im•e. Well: Municipal Water System 5 Ft. 1 FL Cteenda vt (Pante. A B. CI Twat Depth:Cw.d b: eW Wmrptm res 500 Fe w e nai ASTM 3034 PVC Ft. Ft. firer Doe united State Wr« t.aM. MMBM Contracting, Inc. 9/9104 Ft. r.m. P.mp sr r. "°°"' Gane TAN K GPLI R. Ft SEPARATION DISTANCES ® septic ❑ Holding O S.T.E.P. 17 Other. To From Septic Tank Absorption Field Lift Station Holding Tank lublkvm to sewer Line Anchorage Tank 1,250 wM >200' >200' N/A N/A >25' « Steel Two (2) whoa Wrr >100' >100' NIA WA LIFT STATION — NONE ON LOT Latina >5' >10, WA WA Dr Fandron>5' >70' WA WA WV b bA'ann TV « k None Not MtltGa inepaa.orr Pa, a by c~c.n Rem-w BENCH MARK Garage Slab. 100.0 Ft- LEngineer's Engineer'sStamp ••••••.�y�s oFf Inspections performed by: T.L. Kimbroullh Dates: 1" 9/9104 0 49th 2nd 919104 0 •••• -- Department of Health and Human Services approval �;, M-CHAEL'E ANDERSrN+ 0�� by NO CC-UPI f �': $ - f '�%�o�" F • Reviewed and approved by: Date:oe- - -�' iR Municipality of Anchorage Page 2 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: SWO40377 PID No. 051-531-13 MEADOW RIDGE SUBDIVISION LOT 5, BLOCK 5 4�.....Y..... AS -BUILT PLAN MICHNEL E. PNpER90N < 1 SCALE 40' NO. CE4381 ,•'�� Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: SWO40377 GARAGE PID No. 051-531-13 PROFILE AS -BUILT Scale: i" = 10' MUNICIPALITY OF ANCHORAGE cll `7n�/" Development Services Department"�O� On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Sep 08, 2004 Expiration Date: Sep 08, 2005 Permit Number: SW040377 Parcel ID: 051-531-13 Legal Description: EADOW RIDGE ESTATES #5 SUBDIVISION BLOCK 5 LOT 05 Design Engineer: 0014 Anderson Engineering Owner Name: MMBM CONTRACTING Owner Address: NHN HOMESTEAD ROAD EAGLE RIVER. AK 99577 - Site Address: NHN HOMESTEAD ROAD Lot Size: 24392 SO. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: ❑; Disposal Field E Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be In accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. Received By: Issued By: B. Covered, sealed, and heated to prevent freezing. Date: 9 — U `Ci y Date: `6 o Municipality of Anchorage Development Services Department Building Safety Division i On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D.0 ri�_i*-�(- I-_-� Permit Number SW Property owner(s) MM&M Contracting Day phone 6M1236 Mailing address (1) P.O. Box 670495 Chuglia�k, AK 99567 - 9 address (2)� eliA'ROCS Legal description (Lot, Block & Sub'd.) Lot 5, Block 5. Meadow Ridge Estates Subdivision North Addition Legal description (Section, Township & nge) Lot Size 1�i,3%' Acre q.Ft THIS APPLICATION IS FOR: Number of Bedrooms Four (4) Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: q-1, 0 N Waiver Fees: Date of Payment q__1_ -0y Date of Payment: ReceiptNumber. 7fo1� _ t}�M _ Receipt Number. (Rev. 12100) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX September 1, 2004 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 5, Block 5, Meadow Ridge Subdivision North Addition Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 5, Block 5, Meadow Ridge Subdivision North Addition intends to construct a new four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to serve the new home. The subdivision is served by a community water system and no conflicts exist with adjacent septic systems or wells. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system and alternate site. The water service line is also shown. The current drainage pattern along with spot elevations is identified on the Site Plan. The drainage pattern will be maintained after development of this lot is complete. A test hole recently placed on the lot indicated poorly graded sand and gravel with cobbles in the area of the absorption trench. The accepting soils were tested and found to have a percolation rate of 4.4 minutes per inch. No groundwater was found in the test holes during placement and none was noted during the monitoring period. Our design includes the placement of a new 1,250 -gallon septic tank along with a 50' long by 5' wide by 4' effective depth absorption trench to collect and treat the sewage generated in the house. The bottom of the trench will be 7' below the surface. The distribution pipe will be 3' below the surface. A minimum of 3' of cover will be placed atop the trenches and a minimum of 4' of cover will be placed atop the new septic tank. The ground surface on the lot slopes at shallow grades from south to north as shown on the Site Plan. The absorption trench will be constructed parallel with the slope of the ground surface as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 10' from the water service Lot 5, Block 5, Meadow Ridge September 1, 2004 Page Two proposed for the lot and on adjacent lots. It will also be constructed a minimum of 100' from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, �� c Qt'-J� Michael E. Anderson, P.E. Attachments FA MICHAEL E ANDERSON ;t No. CE -438I I 24 S h' : 58951'iB'W 905. 180.33 1" 01 ?� 8700 6113 1000 33100 900.00 8 68916570'E 3082.70 74199 s� 7 8 9 10 h Ec S M 6 R �8 oa 71a �� O Io �O C ,m Q pi 00.88 �. 9� otE3 ba a�� o a 4 W NP9 .IB a.rs <r' 11 ie w �O 3 2 e 5 1 �4 NORT ADDITION g I30o0 10500 6357 W�� •4,'��� a3e00 El' w�cwvi B. �Noe89oN r - ' t` AREA MAP r +`4S3• •°��-i�Dtigt�Eys ���••r SCALE 1' =100' MEADOW RIDGE SUBDIVISION LOT 5, BLOCK 5 eetieaa �o��oaa o o tie TFtt etas 92 6 Four roorn BKOM 1.250 Gallon Z Y Septic Tank G Long Wide (.1 x a' Effective Depth gpeolplion Trench 'of N �o i - 5 / 10' Utility Easement 218.58 •••�aw•y4 O E� y 1 , SITE PLAN •• �, •, No. c "i ••iit i �.•• SCALE 1" = 40' LOT 5, BLOCK 5, MEADOW RIDGE SUBDIVISION NORTH ADDITION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom House 5' Wide Trench System Perc. Rate: 4.4 Min./Inch 1,250 Gallon Septic Tank Application Rate: 1.2 GPD/SF 4' Drainfield Rock 4 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 500 SF Absorption Area 500 SF/5 SF • .5 (Red. Factor) = 50 LF Trench Length THEREFORE: Construct a 50' Long x 5' Wide x 4' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 3' Below Original Ground Surface. Total Depth to be T Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. 2'6" 6" 4'0" Natural Backfill 5' Geotextile Fabric 4" Perforated PVC (Holes Down) Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION •••..� •'�'�°F (NO SCALE) ��.,�p'�,..•- • ••••• , c NOTE: Grade Area Over Trench to Drain Away. Ja=i 4 Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. .�..,� Minimum 10' Separation From Water Services in the Area. %,% Ylduel E.IwoER Minimum 100' Separation From Surface Water or Streams.- 0# � , No. CE. i MUNICIPALITY OF ANCHORAGE•������41kame4 DEVELOPMENT SERVICES DEPARTMENT .•���•••"•.. ��� 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG .._., .._. _._ ....r., ....,..».� .q MRG 1 t^ sMIL7uEl 6 M1aERSOH LEGAL DESCRIPTION- LOT 5, BLOCK 5, MEADOW RIDGE EST. PERFORMED FOR' PAUL MYERS DATE 8/2/2004 PROJECT No • M0478 ���h�::`•• PARCEL ID,#' TECHNICIAN: T. L. KIMBROUGH Pro/esslanal En lme Stam DEPTII TEST HOLE # 1 (fen) 1 OB/OG SLOPE SITE PAN 2 10% 3 4 5 SEE SITE PLAN 6 7 8 POORLY GRADED SANDS WITH COBBLES TO 10' AND BOULDERS > 10% 9 SP SFF FUTURE ASRUILT 10 11 < 10% > 259'0 12 DATE READING 13 (MINUTES) (MINUTES 14 15 16 BOH 17 l8 5 11:30 9.5" 19 20 PERCOLATION RATE• 4_3 (MMflNCII) PERC. HOLE DIA`(INCHES) TEST RUN BETWEEN: 4 FT. and —5FT. WAS GROUND WATER ENCOUNTERED? NO IF YES a) WHAT DEPTHS DEPTH OF WATER AFTER MONITORING: NONE DATE OF MONITORING: 8/31/2004 COMMENTS: NO IMPERMEABLE LAYERS ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. 1, MICHAEL E. ANDERSON CERTIFY TIIAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 9/112004 E DEPWATH of INFT GROSS TIME NET TIM)TERNCHES) (INCHES) DROP TEST HOLE PRESOAKED PRIOR TO TESTING: 1 10:30 9.375" 2 11:00 30 2" 7.375" 3 11:00 9.125" 4 11:30 30 2.125" 7" 6 12:00 30 2.5" 7" MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG LEGAL DESCRIPTION: LOT 5, BLOCK 5, MEADOW RIDGE EST. PERFORMED FOR- PAUL MYERS DATE: 8/2/2004 PROJECT No • M0478 PARCEL IDS{- TECHNICIAN: T. L. KIMBROUGH DErnl TEST HOLE # 2 6rvi) 1 2 READING OB/OG NET TIME (MINUTES) 3 NET DROP (INCHES) 4 5 12:15 6 7 2 12:45 30 1.5" POORLY GRADED SANDS 8 WITH COBBLES TO 10' 12:46 AND BOULDERS 9 SP 10- 0111213 1:16 30 11- 6.875' 12- 5 1:17 13-1 8.75' 16 17 18 19 mi 51TE PAN SEE SITE PLAN I< 10% > 25% DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DyEyATER P (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 1 12:15 8.75" 2 12:45 30 1.5" 7.25' 3 12:46 9" 4 1:16 30 2.125' 6.875' 5 1:17 8.75' 6 1:47 30 2" 6.75" PERCOLATION RATEL4.4 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4 FT. and 5 FF. WAS GROUND WATER ENCOUNTERED? NO 1F YES @ WHAT DEPTH? DEPTH OF WATER AFTER MONITORING: NONE DATE OF MONITORING: 8/31/2004 COMMENTS: NO IMPERMEABLE LAYERS ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. 1. MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 9/1/2004 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 5, BLOCK 5, MEADOW RIDGE SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,250 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of a new 50' long X 5' wide X 4' effective depth absorption trench at the location also shown on the Site Plan. The distribution line in the trench will be placed at 3' below the existing ground surface. Total depth of the trench will be 7' below the existing ground surface. A separation distance of 10' from any water service and 100' between the septic tank and absorption trench and any surface water must also be maintained. A minimum of 3' of fill is required over the absorption trenches and 4' over the septic tank. In lieu of the required fill 2" of insulation and 2' of fill may be placed. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,250 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. Lot 5, Block 5, Meadow Ridge September 1, 2004 Page 2 of 3 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. Lot 5, Block 5, Meadow Ridge September 1, 2004 Page 3 of 3 MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. Parcell.D. Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING 051531.13 1. GENERAL INFORMATION Complete legal description 0 ZD COSA # QC10 3 61 Expiration Date: / 0— / 9 " /0 LM 5, Block 5, Meadow Ridge Estates SubdMslon North Addibon Location (site address) 25200 Homestead Road Chugiak, AK 99567 Current Property owner(s) Steven Kogutkiewicz Day phone 392.6669 Mailing address 25200 Homestead Road Chugiak, AK 99567 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: Four (4) 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well R1 Individual On-site Q Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of Onsite Systems Approval (COSA) based only upon the representations given in paragraph'4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Onsite Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seat affixed hereto and as of the validation date shown below, I verify that my Investigation, based on procedures outlined in the Certificate of Onsite Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure Indicated herein. I further verify that based on the Information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date 1017/2009 -"''OF At +►.c �. r^--------- ;v°------ 5. DSD SIGNATURE >II i uEt E µoccsC+•'�,: /J .• CE .4381 ��r.• J�Approvedforbedrooms. 4 •0 �; �;;.�•••��� Disapproved. +1jwftr sst� lee Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory By: Q (Ra 11A5) Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date:Q Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.orglonsRe _ (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST _ - Legal Description: Lot 5, Block 5, Meadow Ridge Estates Subdivision North Addition Parcel ID: 051531-13• A. WELL DATA Ll Ll� Well type Class A If A. B, or C provide PWSID ter t Well Log (YM) Date completed _ Sanitary seal (Y/N)_ Wires properly protected (YIN) Total depth ft. Cased to ft. Casing height (above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level ft. ft Well production g.p.m. 9 - p.m -WATER SAMPLE RESULTS: Coliform colonies/l00 mL Nitrate mg/L Other bacteria colonies/100 mL Arsenic: , _ mgA Date of sample: _ Collected by'. B. SEPTICAiOLDiNG TANK DATA Tank Type/Material Septic/Steel Date installed 919/2004 Tank size' 1.250 ' gat. Number of CompartmentsTWe Cleanouts (YM) Y Foundation cleanout (YM) Y Depression over tank (YM) N High water alarm (YM) N Date of pumping 10/712009 Pumper SanBary Pumpers C. ABSORPTION FIELD DATA Date installed 91912004 Soil rating (g.p.d./ft= or f?/bdmt) L2 GPD/SF System type 5' wide Trend, Length 50 ft. Width 5' ft. Gravel below pipe 4 ft. Total depth _2_ft. - - Eff. absorption area1�ftp . Monitoring tube Y Depression over field N Date of adequacy test 10/6/2009 Results (Pass/Fail) Pass For 4 bedrooms Fluid depth in absorption field before test 4 In.. Water added 622 ' gal. New depth 6 in. Elapsed Time: 10 min. Final fluid depth 4 in. Absorption rate >= 600 g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) N If yes, give date D. LIFT STATION Date Installed Size in gallons 'Pump ons level at_ in. •Pump off" level at _ in. Datum Cycles tested Manhole/Access (YIN) High water alar level at Meets alar & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot On adjacent lots Absorption field on lot On adjacent lots Public sewer main Public sewer manhole/cleanout Sewer/septic service line Holding tank Animal containment areas Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTICIHOLDING TANK ON LOT TO: Building foundation >s Property line >S Absorption field >5' Water main NIA Water service line >10' Surface water >100' Wells on adjacent lots >200' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line >10' Building foundation >10' Water main >10' Water Service line >10' Surface water >100' Driveway, parking/vehicle storage >25' Curtain drain None Noted Wells on adjacent lots >200' F. COMMENTS' Lot Is Served by Class A Water System. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 10n12009 COSA Fee $ q 10 Date of Payment i0 /0 % Receipt Number 0 V 13 & C1 (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number 11 *�• 49IH L .. *1I ::.+...:..::.:....................� so : MICNAiIb ANMSON- r���•:�-'<.tE=4381 1i ROM COUNTRY REALTY .SA-or pf. f< -S PHONE NO. : 9076981233 z I S. 5's Dec. 07 2004 10:37AM PI • NNe Yom. et � vii . �• • .. AS -BUILT.. I hereby certify that I have surveycA, the following'described Lo Anchorage Rkording Pro4nct, AlAski, �w ments'Fituated thereon are within Lh OXIO overlap or encroach on the property', - 9 no Improvern".0n property I d 4 on the premises In question anyd'ngat,'tle traftsmissioh:hnes or other visibWeasernie except its Wicated hereon. - - Dated it f4li*11W. "Alaska this7 jay, of r.. -A 4 ROMT C.40kth SCALE:. .Registered Lan I Box 77-04%..-Fmo Phonc 694 z ALMSAA 99577" k�( F m ) E)( � 3 r u {C-/< (�� f�.s«)U)a ) ` hi §c ---(Lu \ ❑ R «U ) § § o gx k ) Lu § } < \ - ) g 0 k�( F m ) E)( � 3 r u {C-/< (�� f�.s«)U)a ) 2 )) hi §c ---(Lu E R «U ) ) | k ❑ Eki , 0 a §/§ LU k ) LLJ | _ (U 00 k ƒ \ N=�=5 � ❑ £m > eemq @ /m < LLJ � ® | E LL §£� � LJ Ld ${ < § co 00 \ E 2 ) ) ° ° L f f C.)< § 2 (0. ■\ 2 k (\1 7 § ( k \ { F m ) E)( 3 r u {C-/< (�� f�.s«)U)a £�c 2 )) hi §c ---(Lu E ) °\I | k % 0 a § LU ):» (U 00 N=�=5 £m eemq /m < }p. ${ < (\1 7 ${ < §\i$0000000000 ${ <000000000 \:�::c ${ <o$R9R000 @\{27222222222 77 <�00000000 777�k§Q222;722 »�co )9§i\Inco ]D \»«»g■2§2a J)\Iv 0000\ ,R§��e�&«e § »k I O■ O 2) G ■g 2 R F m ) E)( r u {C-/< (�� f�.s«)U)a £�c 2 )) hi §c ---(Lu E ) R E)( °\I § ):» eemq }p. R Municipality of Anchorage -1 Development Services Department Building Safety Division Onsite Water and Wastewater Program 4700 South Bragaw St P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.enchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 051.531.13 HAA # r) io Expiration Date: S 1. GENERAL INFORMATION Complete legal description Lot 5, Block 5 Meadow Ridge Estates Subdivision No. 5 Location (site address or directions) NHN Homestead Road Current Property owner(s) MM&M Contracting Day phone 688-1236 Mailing address P.O. Box 670495 Chugiak. AK 99567 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, NAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: Four 4 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class A Well ® Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an Independent professional civil engineer registered In the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage Is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seat affixed hereto and as of the validation datg shown below, I verify that my Investigation, based on procedures outlined In the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system Is(are) safe, functional and adequate for the number of bedrooms and type of structure Indicated hbrein. I further verify that based on the Information obtained from the Municipality of Anchorage files and from my Investigation and Inspection, the on-site water supply and/or wastewater disposal system Is(are) In compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Finn Anderson Engineering Phone 522.7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date 1217/2004 L S. DSD SIGNATURE NM c AN=SCN No. a-4381 � Approved for _ bedrooms. t.• Disapproved. Conditional approval for bedrooms, with the following stipulations: Attachments: HAA Checklist X (Rw. 12M Septic System Advisory Well Flow Advisory Maintenance Agreements Supplemental Engineer's Report Other Pat;( Original Certificate Date: &-0 �4 41 Municipality of Anchorage • Development Services Department Building Safety Division ' — On -Site Water & Wastewater Program 4700 South Bragaw St P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.enchorage.ak.us (907)343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: Lot 5. Block 5. Meadow Ridae Estates No. 5 Parcel ID: 051-531.13 A. WELL DATA Well type _ Date completed _ Total depth fL Date of test Static water level Well production If A, B, or C provide PWSID # _ Sanitary seal (YIN)_ Cased to ft. FROM WELL LOG WATER SAMPLE RESULTS: Coliform colonies/100 ml. Date of sample: B. SEPTIC/HOLDING TANK DATA Tank Type/Material SeoticlSWI Tank size 1.250 gal. Foundation cleanout (YIN) Y Date of pumping C. ABSORPTION FIELD DATA fL 9 -p.m - Nitrate mg.A. Collected by: Number of Compartments 2 Well Log (YIN) Wires property protected (YIN) Casing height (above ground) in. AT INSPECTION 0 Other bacteria colonies/100 ml. Date installed 9198004 Cleanouts (YIN) Y Depression over tank (YIN) N High water alarm (YIN) N Pumper New Construction Date installed 9198004 Soil rating (g.p.d./ftp or flbdrm)1.2 GPDISF System type T Wide Trench Length 50 ft Width 5 ft Gravel below pipe 4 ft Total depth 9 ft. EH. absorption area 500 fl? Monitoring tube Y Depression over field N Date of adequacy test Results (PasslFail) For bedrooms Fluid depth in absorption field before test _ in. Water added_ gal. New depth_ in. Elapsed Time: _ min. Final fluid depth _ in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (YM & type) N If yes, give date D. LIFT STATION Date Installed 'Pump on' level at_ in. Datum Size in gallons Manhole/Access (Y/N) 'Pump off level at _ in. High water alarm level at in. Cycles tested Meets alarm 6 circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot On adjacent lots Absorption field on lot On adjacent lots Public sewer main Public sewer manhole/cleanout Sewer /septic service line Holding tank SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line >5' Absorption field >5' Water main >10' Water service line >10' Surfacewater >100' Wells on adjacent lots >200' i SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line >10' Building foundation >10' Water main >10' i Water Service line >10' Surface water >100' Driveway, parking/vehicle storage >5' Curtain drain None Noted Wells on adjacent lots >200' F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name- Michael E. Anderson, RE, Date 12172004 HAA Fee $ 61, j5+ Date of Payment 121 " Receipt Number _(r I SIy SAM (ReJ. 1200) Waiver Fee $ _ Date of Payment Receipt Number, `.rY•� cif 49th * st* 7 *%K104AM L ANDERSM /2' No ct�M ��eea,, �ha��•••i j CDITM REALTY PHONE NO. : 90768131238 Dec. 07 2004 10:37AM PI 'T 1p,� Wr vp ,>s, :_ 181 5*8 OAFS iii Yrls .� \ AS -BUILT' I herey certUy that I hove %;trrveyrd.tl%v tulluwblg:d - tsit nl;;a- propel, -o- 'Anchorage Recordinprecinct,ording rnct. Alacks, and that -the improve., 41M, ments lituabed thereon are within the tropertylinei; and do nonot.;i.- lying a Ah overtap or encroach an the property clikehirthemtoj at .1w Improvements property lyin adjaCent-then-to eugoach .W provimrnt3ph* pro ", r-) 4 .,. .4— "V on the, A 'k�;- , . premises in question and t at. there'Pre no: r6adw-ays. re Y, bmismi'ssiciAlihes or other visfbleeasemertts; cin'iiW except as indicated hereon. - Dated at Eagle River, Alaska 4k &I" u t this dAy of RO=T C.40KNSOR ?:X. SCALE:. Registered LAnd,Sirryeyor No, 54M,- -0456,fagle Ri! 'er, Ain" 99577 box 77 '694 .0 Phone -250