Loading...
HomeMy WebLinkAboutHAMANN ADDN #1 BLK 1 LT 5Hamann Block 1 Lot 5 #051-611-25 Municipality of Anchorage .. a -� Development Services Departmentilll Building Safety Division ` _ On-Site Water and Wastewater Program ,- 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519650 www.muni.orglonsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 050-611-25 COSA# Q Q 03 H0 Expiration Date: / 0 - a S - / O 1. GENERAL INFORMATION Complete legal description HAMANN BLOCK 1, LOT 5 Location (site address) 24636 Coleman Circle, Eagle River, AK 99577 Current Property owner(s) Wilma L. Hamann Trust Day phone Mailing address Lending agency Mailing address Real Estate Agent Mailing Address PO Box 770617 Eagle River, AK 99577 Day phone Audrey Mason Day phone Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 5 3. TYPE OF WATER SUPPLY: Individual Well ❑ Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding Tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Onsite Systems Approval (COSA) based only upon the representations given in paragraph 4 by an Independent professional civil engineer registered in the State of Alaska. Certificates of Onsite Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also Issues.COSAs _upon request to homeowners._ Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of Onsite Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations In effect at the time of installation. Name of Firm _ArcTerra Consulting. Inc. Phone 868-3792 Address 20441 PTARMIGAN BLVD., EAGLE RIVER AK 99577 Engineer's Printed Name KENNLTII M. DUFFUS Date 1 011 6/2 0 0 9 Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes Inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ` ArcTerra can not give any estimate of how long a r!�' system will function satisfactory for current or future OF occupants or can ArcTerra guarantee that no unseen encroachments, deficiencies or discrepancies exist. �* 4 * �. 5. DSD SIGNATURE I ZH tw�Approved for bedrooms. Q it Qf Disapproved. �` sslokii-, -W \rl.� Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory WATERAND Arsenic Advisory ; WASTEWATER Maintenance Agreements � M � Supplemental Engineer's Rei' . l � Other ���ii,,. •...,���� By: n�//%�� u%. Original Certificate Date: /O Oq Municipality of Anchorage • Development Services Department / Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: (IAMANN BLOCK 1, LOT 5 Parcel ID: 050-611-25 A. WELL DATA– WATER PROVIDED BY NATURAL SPRING Well type If A, B, or C provide PWSID # _ Well Log (YM) N (See attached letter)" Date completed 1969 Sanitary seal (Y/N)_ Wires properly protected (Y/N) Y Total depth _ft. Date of test Static water level Well production Cased to _ft. Casing height (above ground) _in. FROM WELL LOG AT INSPECTION ft. WATER SAMPLE RESULTS: Coliform 0 colonies/100mi- Nitrate ND mg/L Other bacteria 0 colonies/100 mL Arsenic: ND mgll Date of sample: 09/21/2009 Collected by: Doug Kenley, PL B. SEPTIC/HOLDING TANK DATA ft. Tank Type/Material Septic/Steel Date Installed 1969 Tank size 1500 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) N" Depression over tank (YM) N High water alarm (Y/N) N Date of pumping 06/09 Pumper JR's Pumping C. ABSORPTION FIELD DATA Date installed 1969 Soil rating (g.p.d.fft2 or ftx/bdrm) 125 System type Crib Length 20 ft. Width 20 ft. Gravel below pipe -12.3 ft. Total depth 2.4 ft. (bottom of effective) Eff. absorption area 9A4 ftZ Monitoring tube Y Depression over field N Date of adequacy test 10/13/2009 Results (Pass/Fail) PASS For 5 bedrooms Fluid depth in absorption field before test 0 in. Water added 750 gal. New depth 0 in. Elapsed Time: __L min. Final fluid depth 0 in. Absorption rate >= 750+g.p.d. Any rejuvenation treatment (past 12 mo.) (YM & type) N If yes, give date _ D. LIFT STATION Date installed "Pump on' level at _in. Datum E. SEPARATION DISTANCES Size in gallons Manhole/Access (Y/N) 'Pump off" level at _in. High water alarm level at _in. Cycles tested Meets alarm & circuit requirements? SEPARATION DISTANCES FROM WELL WATER SPRING ON LOT TO: Septic tank/lift station on lot 10(Y+ Absorption field on lot 100'+ Public sewer main 75'+ Sewer /septic service line 25'+ Animal containment areas 50'+ On adjacent lots 10(Y+ On adjacent lots 100'+ Public sewer manhole/cleanout 1001+ Holding tank 100'+ Manure/animal excrete storage areas 1001+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 4.2'+ Property line 51+ Absorption field 5'+ Water main 10'+ Water service line 101+ Surface water 95'+/-*** Wells on adjacent tots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main 101+ Water Service line 101+ Surface Water 1001+ Driveway, parking/vehicle storage 10'+ Curtain drain 50'+ (None Known) Wells on adjacent lots 1001+ F. COMMENTS * Water system source is a spring with a cistern. " No outside foundation cleanout In -floor cleanout in garage to tank. "'Meets surface water separation for date installed—ore 1973 G. ENGINEER'S CERTIFICATION OF AZ I certify that I have determined through field inspections and review of Municipal records that the above systems are in t �! conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name KENNETH M. DUFFUS r AUNNrn ���C Date IQ/1N2009 i °j�rtrno�� COSA Fee $490.00 Date of Payment /0 Receipt Number (Rev. 11105) Waiver Fee $ Date of Payment Receipt Number Municipality of Anchorage � 4 Development Services Department i Building Safety Division •• " - On-Site Water and Wastewater Program, 4700 S. Bragaw St. P.O. Box 196650 Anchorage, AK 995196650 Page of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT - - Permit Number: PID Number. 050-611-25 N•n`lmn !Z Wastewater System: ❑ New ❑ Upgrade Ad"" Qlypr AV qckq77 ABSORPTION FIELD phahe Nuneer of Betrooms O Deep Ttehhi O Shadow Trrandh Cl Bw O Mand ®Other 0o0 Sal Resp Tdal Depth from "e al grade. LEGAL DESCRIPTION rPnTl 20-4 Bka9r Loc Slodmsan: Depm lopipe Donato tram appal Pads Gnval depth beneath pqa'. Town" Raps. Sedan'. Fol added above orp.hal Wade unk Ft Grave Lanplh. 20 Ff. Well: ElNew El Upgrade Grave walk Fl Number a Yost Dhaenca between InstWell: FI CMstfh =(Prnee. A B. Ct: Taal Depth: Caw w Tote absaplm eat P" Masted 4 Ff D3034 Adler Dae Dnkd SlatCYARMLevel. Installer Das Installed. Unknown you, pump sat at Catng Hayti Above Grana TANK SEPARATION DISTANCES ®Septic ❑ Holding ❑ S.T.E.P.❑ Other. To Septic Absorption Lift Holding lubliclPrivate Mae,ta . caprny From Tank Field Station Tank Sewer Line Unkown 1500" well 100'+ 100'+ NA 25'+ MeteredMnhe.rofCmWotets Steel 2 S.fea,wae 50'+ 100'+ NA NA LIFT STATION Sao Mahaaausr Let Lee,5'+ 10'+ NA NA Get 4.2'+ 10'+ NA NA -puhM ow towel at •Pump dr level a. Hph water tem a Fandeon n N F NA NA NA NA P'••p Maks a Mode Eloc:V c Inspection. Wormed by cutan Dram Reneka BENCH MARK Looaon ea DewphM Bottom of sidin Attuned Elevation: 100 FL 1re` S��'a� .�K`4,, Consulting tat 1 o/1 3/og Inspections performed by: Arcterra Dates: .2nd ♦ KENN 777 e DUFFUS Development Services Department Approval ♦♦c CE 11 ♦ Jf 0�,� Reviewed and approved by: Date: ♦♦��'�/� (Rad I%=) October 13, 2009 Wilma Hamann P.O. Box 770617 Eagle River, AK 99577 RE: fIAMANN S/D, ADD //1 LOT 5, BLOCK 1 Dear Wilma, Per your request, we have inspected the on-site water and wastewater systems of the above referenced property. This investigation was based on observations of the day in which the septic adequacy was performed, information from others and available Municipality of Anchorage (MOA) record documents. Based on the above information it appears that the property was developed between 1958/59 and no record documents of the existing systems were. found at ADEC or the Municipality of Anchorage (MOA). This is not uncommon for this area within the time this property was developed. The property has an existing single-family 5 -bedroom I -story structure with a walk out basement. The property is served with a 1500 -gallon septic tank with crib disposal field and a spring fed concrete cistern (see attached photos). Discussions with DSD Staff indicate that since it is not a well they can not certify the system even though the water meets current water quality standards. Others performed the water quality testing, with a sample collected on September 21, 2009, and attached to this report. On October 13, 2009 the septic adequacy test was performed. Prior to testing JRs Pumping pumped the 1,500 -gallon septic tank. The absorption field monitoring tube was dry at the start of the test and 750 gallons of water were added at the monitoring tube. The septic field readily absorbed the water and was dry at the end of the test. The system absorbed the required amount of 150 gallons per bedroom per day for a 5 - bedroom residence. It is my opinion that the system's absorption capacity exceeds that of a 5 -bedroom house. It appears that the existing, undocumented septic system is sized as a 5 -bedroom system. Feld measurements were taken and a testhole performed by Doug Kenley, PE documents that the system does not encroach bedrock or ground water. Please see attached drawings. The septic tank is approximately 95'+/- to surface water (see attached as -built) and conforms to separation distances required at the time of installation from the information obtained from municipal records. Presently the tank is less than 5 feet from the building foundation, but met the current separation distances ` Al2CT1:1Z1ZA CONSULTING, INC If 212 E. 51° Ave, Anchorage, AK. 99503 f Office (907) 868-3791, Fax (907) 868-3793 October 13, 2009 Wilma Hamann P.O. Box 770617 Eagle River, AK 99577 RE: fIAMANN S/D, ADD //1 LOT 5, BLOCK 1 Dear Wilma, Per your request, we have inspected the on-site water and wastewater systems of the above referenced property. This investigation was based on observations of the day in which the septic adequacy was performed, information from others and available Municipality of Anchorage (MOA) record documents. Based on the above information it appears that the property was developed between 1958/59 and no record documents of the existing systems were. found at ADEC or the Municipality of Anchorage (MOA). This is not uncommon for this area within the time this property was developed. The property has an existing single-family 5 -bedroom I -story structure with a walk out basement. The property is served with a 1500 -gallon septic tank with crib disposal field and a spring fed concrete cistern (see attached photos). Discussions with DSD Staff indicate that since it is not a well they can not certify the system even though the water meets current water quality standards. Others performed the water quality testing, with a sample collected on September 21, 2009, and attached to this report. On October 13, 2009 the septic adequacy test was performed. Prior to testing JRs Pumping pumped the 1,500 -gallon septic tank. The absorption field monitoring tube was dry at the start of the test and 750 gallons of water were added at the monitoring tube. The septic field readily absorbed the water and was dry at the end of the test. The system absorbed the required amount of 150 gallons per bedroom per day for a 5 - bedroom residence. It is my opinion that the system's absorption capacity exceeds that of a 5 -bedroom house. It appears that the existing, undocumented septic system is sized as a 5 -bedroom system. Feld measurements were taken and a testhole performed by Doug Kenley, PE documents that the system does not encroach bedrock or ground water. Please see attached drawings. The septic tank is approximately 95'+/- to surface water (see attached as -built) and conforms to separation distances required at the time of installation from the information obtained from municipal records. Presently the tank is less than 5 feet from the building foundation, but met the current separation distances Hamann Add L5, a l October 13, 2009 Page 2 of 3 at the time of development. An in -floor drain within the structure acts as a cleanout for the mainline in the house to the tank. All other separation distances conform to present code requirements. From available data and visual observations, it appears that this system poses no health or safety threat to adjoining properties or other individuals. The assessment of the condition of the septic applies only to the conditions as of the day tested. The absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all septic systems is subject to these various and dynamic characteristics and are outside the control of the evaluator of the septic system. Therefore, ArcTerra cannot give any estimate of how long a system will function satisfactory for current or future occupants nor can ArcTerra guarantee that no unseen encroachments, deficiencies or discrepancies exist. If after review of these records you or any of the underwriters have any questions regarding the adequacy of this system or the methods and/or procedures employed during our inspection or evaluation, please feel free to contact me at (907) 696- 6111/Fax (907) 696-8111. Respectfully, ArcTerra Consulting, Inc. Kenneth M. Duffus, P.E. Attachments: As Noted AS -BUILT SYSTEM DETAILS/SITE PLAN Permit# PRE -1963 HAMMAN S/D#1, LOT 5, BLOCK 1 PID# 050-611-25 6SPS49. HDPE IV \ X 4,4 / ti3�s2 t 2 .� A -C=31.2' B -C=29.9' A -D=34.7' C' B-D=33.2'm� A -E=80.7' b1500 B-E=51.1'A-F=N/A :IC SEWER ROCK B-F=N/A AZ9s � Alf �r 1 9 T *�l ' KENNETH M. / CE -7116 qb' FESSIO�= \\Server\etoroce\WELL & SEPTIC - Filed By Le .f Lot 5 o 40.�y O � PN 2 »cre/e =Ez.. 20x20 d 'l SCALE- NTS 1• = 72.8 a FINISHED GRADE r9l vwnROCK 1 20••/ - PREPARED FOR: WiLMA L HAMANN TRUST PO BOX 770617 EAGLE Rl1•ER. AK 99577 (907)694-2776 FIELD BOOKS CpeVTED. saINDMtLOS tcK0'M- : STA"I* NA KMDASBULT.LOS 10 20 09DeG ' SW161ACRD ntE: " 09-060 09-M SEPDMdwq Hammon SubA\AOan/1\Block 1\Lot 5\Hcmonn.c�9 "/twee" // L6t L GRAPHIC SCALE- 1 Inch - 80 f«r 40 zo 6 20 40 go t 0 FOR: _ r 10/ -1s -= -- 20/2009 Lot5 Block 1 Little Bear Services Grid AS -BUILT 2951 Carriage Drive 161 HAMANN $UBD. Anchorage, Alaska 99507 Drawn by Field Book ADDITION NO. 1 (907) 350-5541 r I hereby certify that the property described hereon has been surveyed � by me, or. OF, at my direction, and that the improvements situated thereon A�\ ,, 11 are within the property lines and do not overlap or encroach on the ���••"' "�is1 property lying adjacent thereto unless otherwise shown. That no �/ �, '•.fj` improvements on the property lying adjacent thereto encroach on the GS A A mises in question and that there are no roadways, transmission 9 * :'f lines or other easements on said property except as shown. It is the responsibility of the owner or builder, prior to construction, to verity proposed building grade relative to finish grade and utility // BOBBY F. BUBNErr an connections and to determine the existence of any easements, covents, 19-6464 Joe or restrictions which do not appear on the recorded subdivision plat. AW listed distances prevail over scaling. SSIONIY \ Reproduction may cause distortion. Sent By: KENLEY CONSTRUCTION SERVICES; 907 248 5774; Oct -18.09 5:28PL1; p,RrLtitU_U FCR N1:UA HAIA.ALN — — — — — — — — LECAL DLS(R'PTI'kl. HAUANr S/D. D10CY 1, LOI 5 _ — — —CA IE: 10/03/09 _ DLpTH z- cn — —Solt S LOG a FtFCOLAf10P! TLSf pi7ac. TCST HULF Cp/CM cn�e haw!des to 21 B o.1t. � �1'�yN7y�•�J'A` //7'Yul a c; i r mcy DEVTII 10 DAlL GROU\0'A.\�tR _ n0!4 IV/03/09 10/12/099 Page 2/2 1 OF A4 11 L r � r r:rl rin I wAIER ItVEL n_1 uFOa HEAMG (M.) PE'tCV.ATV,I RATr _ (UINJIN.) TESL RUN 6UBEEN_ — rl. AND_ _ FIU;DAKtD FL'; FUDR mfxrs vs — . NC — — PERC. 141 E D'A. — . (HI ) Aiia Dr IFFU— I CJV!!FNI Hrl PEI+.00lA B0tl IrST I'lC.r(MVFD. T-Sf uC�Y0 P:F. G't1:Cra7 NA' 8 _U FCCR C0A7�APrp To SiNEAa P1T E WAS TNA- ff.4'nS.TAU,U Of kOnckT HAUAl15.— — — — — — — — — — — — �rH.,WA'iU F.Y r8:C Hr1::FY CIItT,F" irfA.i 11+5 'FA; PLkFCI+N'G R! ACCVii)AF:::F. VIM ALL $FAr 3 FACN'UI'AL I;UIE'EI IqS IN rFt tv CR lml' DAIT. I�Z� AS I KCNLCY C k. 1876 Ye Sent By: KENLEY CONSTRUCTION SERVICES; _.907 2`46 5774; 5615301 SOSEMrCMMrtal wvi SOS ReLd 10951I9001 Ck"t flame Douglas Kenley P.E. ?reject Waalala 09110 Cliest Sample i0 Hamarm SID# 1111, 1.5 Matti. Dr6nkinit Water SamOk Remarks: Oct -9.09 1C:20AM; Page 1 06.56.32 a m 10-07-2009 2 M Plotted Datdl'iene Cdktted DdclTimo Receind betemmt Teckn(eal Dicacter 106'06/2009 1214 OMI/2009 17A5 09/228009 11:10 Strobe" C. fAe NlcrobloloaY Laborato Colony Count 0 m0100mL i42092220 A (<2W) 09/22/09 DLC Total Colircm 0 M1100mL 3.42092211) A (41) D9/27)09 ULC Fecal C0lirorm 0 ce0100mL ;42092220 A 403 o9t22/09 DIC Allwoble Ren Aealyus Pwwcw Rnulu POt. Ureu 4Med CoataimlD Limits Dar Dote Imt mettle by LGP/M! Arsenic ND SOD utL 5P2%8 C (<lo/ I0f02l0910101M NRB Matas DaparGaant Total Nitrtic/Nit i't-N ND 0. IOU mtJL 1M2D450CN03-Y 0 (<IO) 10/03109 ICE NlcrobloloaY Laborato Colony Count 0 m0100mL i42092220 A (<2W) 09/22/09 DLC Total Colircm 0 M1100mL 3.42092211) A (41) D9/27)09 ULC Fecal C0lirorm 0 ce0100mL ;42092220 A 403 o9t22/09 DIC M Mn.'... October 13, 2009 ARrV CIERRA ENGINEERING AND SURVEYING, INC. Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program P. O. Box 196650 Anchorage, Alaska 99519-6650 RE: HAMANN S/D ADDN #1, BLOCK 1, LOT 5 — ON-SITE WATER & WASTEWATER SYSTEM The owner has requested we proceed forward to obtain a COSA on the subject lot. As part of the process of reviewing the files and investigating the property it was determined that the house was constructed in 1968/69 and no record documents of the existing system were found at ADEC or the Municipality of Anchorage (MOA). The existing structure is a single-family 5 -bedroom 1 -story structure with a walk out basement. The property is served with a 1500 -gallon septic tank with crib disposal field and a spring fed concrete cistern. We tested and passed the septic system. Discussions with DSD Staff indicate that since the water supply is not a well, they could not certify the system even though the water meets current quality standards. Testing for the water quality was performed by others and is attached to this letter. In addition to the above information we arc providing the following: • Survey as -built. • Septic as built documenting the system and separation distances. • Testholc verifying depth to water table and bedrock • Current water samples • Inspection Report • COSA Form • COSA Checklist Civil Design ; On-site Well/Septic; Land Development; Planning Hamann Add L5, B I October 13, 2009 Page 2 of 2 We were unable to locate any public or private wells within 200' of our proposed system location except as noted. There is no surface water within 50' of the existing system as required at the time of construction or any known curtain drains within 50'. From available data and visual observations, it appears that this system poses no health or safety threat to adjoining properties or other individuals. If after review of the attached information you have any questions, please contact me at 696-611 UFAX 868-3793. Respectfully, ArcTerra Consulting, Inc. Kenneth M. '.E. Attachments: Septic as built COSA Checklist COSA Form Septic Inspection Report Survey as built - Little Bear Services Water Samples - Doug Kenley, P.E. Testhole - Doug Kenley, P.E. 20441 PTARMIGAN BLVD • EAGLE RIVER, AK 99577-8736 • Pit (907) 868-3792 • FAX (907) 868-3793 � rte\ .,:.. ,� � -• �., r �\Y AS -BUILT I hereby certify that I have surveeyyed the following described property: L- O T S,$/ e L. J, H2,nn r o% !7(, i ,i.. f .y„ r' -F f5�, i'l44). k'i k•, ...�. Anchorage Recording Precinct, Alaska, and that the improve- ments situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvements on property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Eagle River, Alaska this1 Y— ' Jay of 200__ ROBERT C. JOHNSON SCALE: Registered Land Surveyor No. SWLS 1' :`, o Box 77.0456, Eagle River, Alaska 99577 Phone (907) 694:2543 October 13, 2009 AR ERRA ENGINEERING AND SURVEYING, INC. Municipality of Anchorage Dept. of Health & Human Services On -Site Services Section P. O. Box 196650 Anchorage, Alaska 99519-6650 RE: HAMANN S/D ADDN $1, BLOCK 1, LOT 5 -- ON-SITE WATER & WASTEWATER SYSTEM The owner has requested we proceed forward to obtain a HAA and COSA on the subject lots. As part of the process of reviewing the files and investigating the property it was determined that the house was constructed in 1958/59 and no record documents of the existing system were found at ADEC or the Municipality of Anchorage (MOA). The existing structure is a single-family 5 -bedroom 1 -story structure with a walk out basement. The property is served with a 1500 -gallon septic tank with crib disposal field and a spring fed concrete cistern. We tested and passed the septic system. Discussions with DIIHS Staff indicate that since it was not a well they could not certify the system even though the water met current quality standards. Testing for the water quality was performed by others and is attached to this letter. In addition to the above information we are providing the following: • Survey as -built. • Septic as built documenting the system and separation distances. • Testhole verifying depth to water table and bedrock • Current water samples • Inspection Report • COSA Form • HAA Form We were unable to locate any public or private wells within 200' of our proposed system location except as noted. There is no surface water within 50' of the existing system as Civil Design •F On-site Well/Septic •I- Land Development + Planning required at the time of construction or any known available data and visual observations, it appears that safety threat to adjoining properties or other individuals. Hamann Add L5, B 1 October 13, 2009 Page 2 of 2 curtain drains within 50'. From this system poses no health or If after review of the attached information you have any questions, please contact me at 696-6111/FAX 868-3793. Respectfully, ArcTerra Consulting, Inc. Kenneth M. Duffus Attachments: HAA Form COSA Form Septic Inspection Report Testhole - Doug Kenley, P.E. Water Samples — Doug Kenley, P.E. Survey as built — Little Bear Services Septic as built Owners Report 20441 FTAk%IIGAN BLVD • EAGLE RIVER, AK 99577.8736 • Pit (907) 868-3792 • FAX (907) 868-3793