Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RANNA LT 2
P,anna Lot 2 #041-032-13 MUNICIPALITY OF ANCHORAGE �p�cnt On -Site Water & Wastewater Program "o�F PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite i11 ' Department On -Site Wastewater Disposal System Permit Permit Number: OSP231105 Effective Date: 5/18/2023 Work Type: SepticTank Upgrade Expiration Date: 5/17/2024 Tax Code Number: 04103213000 Site Legal Address: RANNA LT 2 G:2142 Site Mailing Address: 6940 MONTAGNE CIR, Anchorage Owner: MEACHAM GARY LEE Lot Size in Sq Ft: 68482 Design Engineer: GARNESS ENGINEERING GROUP LTD Total Bedrooms: 3 This permit is for the construction of: ❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing i &ft-eivBd=Sy: 1 ` ut e G Date: Issued By: Date:�8l/Z 3 MUNICIPALITY OF ANCHORAGE 7 Develo went Services Department bj`" P P � �� Phone. 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTICNVELL PERMIT APPLICATION Parcel I.D. 041-032-13 Property owner(s) GARY MEACHAM Day phone Mailing address 6940 MONTAGNE CIRCLE *ANCHORAGE, AK Site address 6940 MONTAGNE CIRCLE *ANCHORAGE, AK Legal description (Sub'd., Block & Lot) RANNA; LOT 2 Legal description (Township, Range & Section) Lot Size Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑ Initial 0 Single Family (SF) El Septic Tank 0 Upgrade El(w/wo AD U) (D) El Holding Tank ❑ Renewal ElDuplex Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 2 7 5 Waiver Fees: Date of Payment: Date of Payment: Receipt Number: 030 5 `i G Receipt Number: Permit No. OSP 2 2� O 5 Waiver No. GADevelopment Services\Building Safety\On Site Water and WastewaterTormsUient Forms\Permit Application.doc Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231105, Deb Wockenfuss, 05/18/23 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231105, Deb Wockenfuss, 05/18/23 �. G`� T -D � GiY ua t.e a 1�u���'1 � � �8 � � � VMC/, C"M Municipality of Anchorage Development Services Department Building Safety Division ad= n �\ On -Site Water & Wastewater Program, 4700 Bragaw St. - P.O. Bon 196650 Anchorage, AK 99519-6654 www.cf.enchorage.ak.us (907) 343-7904 Page 1 of 3 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number. SW090155 PID Number: 041-032-13 Name' JIM JACKSON Wastewater System: 0 New O Upgrade J A9 Address: 7040 MONTAGNE CIRCLE * ANCHORAGE, AK ABSORP 90N FIELD Phone: (907) 830-6767 No. of bed rns: ❑ Deep Trench O Shollorr Trench B Bed 0 idound 0Other LEGAL DESCRIPTION Soa Raung: 2.0 Total Depth from orVnW grove; 2.5 TO TOP ,n sq. TL OF SAND FL Block: Lot. Subdivision: Depth to pipo bottom from ortglnai grade: Grwd depth bemcM papa: — 2 RAN NA 2.0 Ft 0.50 F, Township: Range: Section: M addcd obovo odglrwl grodo: Grace+ t:rVh: — — SEE DWG. FL 25 Ft WELL: ❑ New p Upgrade Grovd width: 10 Humber of arwo: 2 Diala+xo betnc &M: 5 M r,, Ciaorlr;cat;on Privolo, 0.13.6: TotW Depth: Cascd To: Total abowpt;on moo: Pipe matod}of; PRIVATE 61 fl 61 FIL 250 so. rt D 3034/ F-810/SCH 40 Drfser. ALPINE DRILLING Data Drtibd: 10/5/09 Static Wotcr Lcvot: 10 Inetonar_ SANDERS & SANDERS. Dato &r tonod- 8726-27/2009 nerd: 10 rump sot ft He+ght arow Grow 2+ TANK CPU58Ft. n. SEPARATM DISTANCES 0Septic ❑Holding t3S.T.E.P. Ll Other* To Septic Absorption Ult Halving ubik/Privato Uo `iocturon GREER car�Ar in 1500 From Tank Field Station Tank sonar unoa Well 100,+ 100'+ 100'+ — 25'+ Moto": STEEL Number W comporlmonto: 2 Sur -face water 100'+ 100'+ 100'+ — — p� UFT S`I'A�"M Lot Line 5'+ 1'+ 5'+ — — Slso !n grdbm: 1500 Idanvfooturor. GREER QUANICS Foundation 5`+ 10'+ 5'+ — — 'Pump on love! at -Pump off 6e at High valueolarm at, TIMER TIMER 44 Curtain Drain NONE KNOWN P— Lt-3oko C model.102,� � 9' "e S P—TE-30—PLUS iV;-^ Remarks: *THIS IS A QUANICS AEROCELL UNIT BENCH BARK Location Ord Do=V Von: 0*PER WAIVER, ISSUED WITH PERMIT. TOP OF MANHOLE 100.78 R Inspections performed by: GEG, Ltd. Dates: 1st 8/26/09 ENCIHEEasst� EG�oopL Development 2nd 8/26/09 3rd 8/26/09 Services Department Approval �� X011 �. 4 T 7dad Conditional approval: Date: • • .1. 1. • • • • • • • • • • p f y ness, Q pQo 9. CE —79 3 m j .•� o �p�°'pror@9gto�o4� eview �O &aate:L2=- 3�" ed and approved by: ( D�000�� �. G`� T -D � GiY ua t.e a 1�u���'1 � � �8 � � � VMC/, C"M GARNESS ENGINEERING J, Ltd ENGINEERING, SALES CONSULTING June 30, 2020 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Rd. P.O. Box 196650 Anchorage, AK 99519-6650 (907) 343-7904 oanics 1 e ro C e fl , Alaska Authorized Dealer Ref: Ranna S/D; Lot 2 (7040 Montagne Circle, Anchorage, AK) Memo concerning converting CAT III AWWTS to CAT 11 AWWTS septic system To whom it may concern: The permitted septic system was installed on the referenced property in 2009 and started up shortly after the installation. ARM Septic Services, LLC recently checked the monitoring tubes in the drainfield and found them to be dry. In order to simplify the operation and maintenance of the system, we are proposing that this unit be permanently configured as a CAT II system. Our justifications are as follows: The receiving soil has a percolation rate of 40 minutes per inch (per James Sizemore, P.E. 1995 soil log). Given this percolation rate, a 2.0 gpd/sq.ft. application rate is required for a Cat III system and a 1.0 gpd/sq.ft. application rate would be required for a Cat II system. There is 2 foot of MOA filter sand below the drainrock in this drainfield. After the effluent passes through 2 feet of MOA filter sand, the effluent should meet Cat III effluent quality levels. The residence on this property has a total of 3 bedrooms, so 225 sq./ft. of absorption area is required for CAT III effluent (450 gpd / 2.0). The existing 2009 drainfield has 250 sq./ft. of absorption area. In short, the drainfield meets the Cat III sizing requirements. We would like to note that the 2009 Inspection report incorrectly states the bedrooms to be 4 -bedrooms, but MOA records show it to be 3 -bedrooms. We request this be amended on the Inspection Report. At this time. we request that your department approve a CAT II configuration to be used at the referenced property. Upon your concurrence, we will have ARM Septic Service, LLC., go to the property, remove the actuator from the ball valve or leave the valve in the open position, and ve them plate a CAT 11 sticker on the control panel. cereiy, Jeffrey ! 'd�hegs,_PIE., M.S. PresidJt �� 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program Mayor Dan Sullivan October 8, 2012 Attention: Telephone Service Provider for Lonnie Prairie Chicken 6940 Montagne Circle Anchorage, Alaska 99507 (907)240-6378 Reference: On-site Septic System Advanced Wastewater Treatment Telephone Requirements To Whom It May Concern: The On-site Water & Wastewater Program (On-site) regulates the use of advanced wastewater treatment systems (AWWTS) in the Municipality of Anchorage (MOA). The type of AWWTS installed at 6940 Montagne Circle is required to be continuously monitored from an off site location using a telephone service connection. The subject property owner indicated a connection to his property has not been provided and that as a result his AWWTS is out of compliance with MOA code requirements. In an effort to bring the subject system into compliance, could you provide On-site with an update regarding when telephone service will be extended to the subject property? Than �y�o�u,�" Vw aes "Jay" Crewdson, P.E. On-site Water & Wastewater Program Community Development Department Municipality of Anchorage T: (907)343-7908 F: (907)249-7601 E: crewdsonja@muni.org Mailing Address: P.O, Box 196650 • Anchorage, Alaska 99519.6650 • http.-I/www.muni.org Municipality of Anchorage Development Services Department •= ``. Building Safety Division •+€Y - On -Site Water & Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Page 1 of 3 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number. SW090155 PID Number. 041-032-13 NOTe1 JIM JACKSON Wastewater System: ■ New ❑ Upgrade y Address: 7040 MONTAGNE CIRCLE a ANCHORAGE, AK ABSORPTION FIELD Phone: No. of Bedrooms: (907) 630-6767 4 O Deep Trench a Shallow Trench ■ Bad 011ound OOther LEGAL DESCRIPTION sd Rahn: 2.0 Taal Depth Trent original grade: 2.5 TO TOP OF SAND r< cPp/sa. FL Block: lot: Subdivision: Depth to pipe lwaaa from Original grade: Gro• depth beech pipe: — 2 RANNA 2.0 n. 0.50 FL Township: Range: Section: — — — fill odded 0b aHynal grode: rHa.ei boon: 25 SEE DWG. FL rL ■ New [I Upgrade craeal sidth: 10 NvmMr a en«: 2 Dblanee set lines: lines:WELL: 5 R n Ckeeimf int PrNae, As.0 : PRIVATE Tad Depth: 61 Coved Td 61 Total aseorpaon area: 250 Pipe nalwial: D 3034/ F-810/SCH 40 n In. so. FL Dr . ALPINE DRILLING We Drwed: 10/5/09 stoke Isl• el. 1 10 kadoner. SANDERS & SANDERS Dae k etoeed� 8/26-27/2009 s< 'hell:Pump 10 set At: 56 casing Height Alw.e Gran d:10 2+ TANK Dp„ rt. FL SEPARATION DISTANCES aseptic ClHolding ■S.T.E.P. ■Others To Septic Absorption Lift Holding ubik/P&'at• YO1d°dv«' GREER Capacity in gdem: 1500 From Tank Fald Station Tank s.s« LMee Well too'+ too'+ 100'+ — 25'+ Hotwbl: STEEL Numbr d aar^paNner,4: 2 Surface water 100'+ too'+ 100'+ - - LIFT STATION Lot Line 5'+ ••t'+ 5'+ — — Size In gallant: 1500 uamdaawpr GREER QUANICS M W al wry OII b..1 aL Mph aa.r •lain, at- lFoundation Foundation 5'+ to'+ 5'+ — — TIMER TIMER 1 44 Pwp Hake t 11 : Electrical lree, bne p•elonned by S Curtain Drain NO KNOWN P—TE-30-1 Remarks: *THIS IS A QUANICS AEROCELL UNIT BENCH MARK lacalion and Dwcripaon: "PER WAIVER, ISSUED WITH PERMIT. TOP OF MANHOLE A.eumM Eb,akom 100.78 R ENGINEERS SEAL Inspections performed by: GEG, Ltd. Dates: 1st 8/26/09 d 8/26/09 09 s Development Services Department Approval 4 T : p...:..1.... . 0 Conditional approval: Date: 0"" "'. r.y ness P CE -79 3 - 30' C"1 \404pa�fesp00p� Reviewed and approved by: I ate: u PERMITNUMBER: AS—BUILT DRAWING PARCEL ID NUMBER: SWO - SW090155 041-032-13 A B FCO 24.01 7.01 STI 75.3 69.33 RISER 05.19 79.60 ACLI 00.05 03.74 ACL2 90.07 06.01 L .N 96.15 92.04 SMP 90.21 93.75 \ COI 73.51 07.56 \ CO2 163.00 161.03 CO3 101.01 100.96 `— —1 VTI 142.95 139.79 MTx 1161.111160.701 NEW ORNNRELD ^!711_y,,t•'Y`� �fy _ CO` . RESERVESITE \ \ 1y7 TNII EV CONFIRMATION ONN WAS \� 71 _ INCORREC�f ON DEsICN 1 `� N �/ ACL2 ACL1 SAMPLE PORE y. (SMP) LY 100• SETBACK 500 GALLON _ E.P. TANK NEW 3 BEDROOM HOUSE 1• �p' ��\ MONTACNE CIRCLE GARNESS ENGINEERING GROUP, Ltd. • - - - CONSULTANTS & GENERAL CONTRACTORS -�••• •��_• •• I L T11oo11 Poo. fort tot . NR11w4E. w 99507 . 91q•E (907)317-9170 9 I" (w»av-ax.a • �Ilc ....P.•.�•�o�••�M—+ JIM JACKSON LEGAL DESCRIPTION: RANNA LOT 2 E OF WORK: AS—BUILT DRAWING 0 HE NUMBER: PAGE NUMBER 830-6767 1 2 OF 3 SYSTEM VQ� f I BY: r T• A.IJ J.G. fin. _ 42�1p 12/9/2009 PERMIT NUMBER: AS -BUILT DRAWING PARCEL ID NUMBER: SWO90155 041-032-13 FINAL GRADE TOP OF MAN •)ANDY VALVE 650 OUANICS 100.02 HOLE - 1D0.7s , AEROCELL UNIT—\ TOP OF INLET - INVERT OF BUNG INLET - 93.53 - 1500 CALLON S.T.E.P TANK 10 GAUGE, RATED FOR 10 'BURIAL FINAL GRADE . 98.15-98.81 TOP OF SAND 95.00 – ELEVATION OF BOTTOM OF TESTHOLE - 84.00(WATER O 86.00) –TOP OF TANK OUTLET - 94.18 FABRIC TO DRAINFIELD I ORIGINAL GRADE - 97.50 INVERT OF DISTRIBUTION UNE - 95.50 BOTTOM OF BED . 93.00 - - GARNLSS ENGINEERING CONSULTANTS S GENERAL CONTRACTORS ..�9.....«_--+--••• = GROUP Ltd. PREPARED FOR: PHONE NUMBER: PACE NUMBER: ••••• • • ••••• •• JIM JACKSON 907-830-6767 3 OF 3 QA ey CO ness: LEGAL DESCRIPTION: DRAWN BY: VO'D,v CE •,•' �te4� RANNA S/D; LOT 2 A.J.G. �0 'iz.�A to ��Ao TYPE OF WORK: DATE. 40O4pO�"glov ao PROFILE AS—BUILT OF NEW SEPTIC SYSTEM 12/9/2009 ooaoopp0 �aOFA o0 GROUP, Ltd. 4:10 GARNLSS 6" ENGINEERING 9 y y*ppp - - --- .---•--• CONSULTANTS d GENERAL CONTRACTORS+-•••--•�-••a=•+^�-^-�- A ...... ... . .. .. ... ... ... 101 • II,G,ON�LF. IK iD90) • h10"L i0 )-!1]Y • fAr: (W7)IM-32" • VEBSIfL ,s,rww,prrYq.wn 3701 E 11M1011 MOID. WfC 2" SOIL LOG - PERCOLATION TEST' .... 1 ........ ........ � LEGAL DESCRIPTION: RANNA• LOT 2 .•.J ff Gorn ss.: Q a •• PERFORMED FOR: E-7 •' eQO JIM JACKSON DATE: 8 26 2009 '. SFO DEPTH 30 ��'dp,°j Spon too ��O0000�� __ (feet) _y__yy ORGANICS CONFIRMATION TEST HOLE 1 �yny — 6 SOIL CLASSIFICATIONS 2�lllfORGI 4" 2" i+.' t GP ML 3 GM CL 4 GC OL N °. •°° : SW MH 5 • SP CH SM : OH SM TO ML SC 6 w/SOME GRAVEL 7 (MORE SILT PTH TO DATE GROUNDWATER w/DEPTH) DWA ER 8 DRY 8/26/09 9 SCALE: 10 DATE READING CLOCK NET TIME WATER LEVEL NET DROP 11 TIME (MINUTES) READING (INCHES) 8/26/09 12 B.O.I1. 13 14 15 16 17 18 PERCOLATION RATE 15 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19 TEST RUN BETWEEN 3.5 FT. AND 4.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: E YES ❑ NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: KYLE MAUS COMMENTS: GEG, Ltd. I. JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 17 q PERFORMED ALL BY WITH STATE -be 1 4:10 — 6" — 2 4:40 30 4" 2" 3 4:40 — 6" — 4 5:10 30 4" 2" 5 5:10 — 6" — 6 5:40 30 4" 2" Cv ■ ■ ■ OM :RIF:".c DriIIi ,g ■ ■ ■ FW, :907 345 0202 Oct.07 2009.03:46PM P1 Alpine Drilling & Enterprises Well Log Permit Number. ttSW 90 0155 Date of Issue: 8-20.09 Date Started: 10.05-09 Date Completed: 10-05- 9 Legal Description: Ranna Lot 2 Parcel Identification Number: 041-032-13 Is well located at approved permit location? x Yea ❑ No Property Owner Name & Address: Jim Jackson PO Box 92301 Anchorage. Alaska 99509 Borehole Data: Depth (ft) Method of Drilling x air rotary ❑ cable tool Soil Type, Thickness & Water Strata From To Casing type: steel Stick-up 0 2 Wall Thickness: 11 inches Gravelly silt Z 8 silt 8 13 Diameter. f Inches Depth: fL feet Liner Type: _ Diameter: + inches Depth: , feet gravelly silt 13 41 Casing stickup above ground: 2 feet Static water level (from ground level): Qfeet silt 41 SO silty water sand & gravel 50 54 silty gravel 54 58 Pumping level: 60 feet after 2 hours pumping 10 gpm Recovery Rate: LQ gpm water sand &gravel 58 61 Method of Testing:it i Well Intake Opening Type: x Open End ❑ Open Hole ❑ Screened Start _ fect Stopped _ feet ❑ Perforations Start _ feet Stopped _ feet Grout Type: bentonite Volume: Lig th Start 0 feet Stofeet Intake Depth _ feet SPump: Pump size _ hp Brand Name Well Disinfected Upon Completion? s Yes ❑ No Sr - Method of Disinfection: chlorine rablett Comments: S1 Grk q t 1 Dov c\ Well Driller: Alpine Drilling & Enterprises Vo Gl PO Box 110496 Anchorage AK 99511 Development Services Department Building Safety Division © A -W On -Site Water & Wastewater Program 4700 Elmore Street "!`e P.O. Box 196650 Mark eegich Anchorage, AK 99519-6650 Mayor w ,muni ora/onsite (907)343-7904 Pump Installation Log Well Drilling Permit Number: SSV_ Date of Issue: Parcel Identification Number: Replacement Only: YES NO Legal Description Lor 2, Ranna Property Owner Name & Address: A'orthwood Homes Pump Installation Date: 11/11/2009 Pump Intake Depth Below Top of Well Casing: 58' feet Pump Manufacturer's Name: Myers Pump Afodel: 1/2-12GPA1 Pump Size 1/2 hp Pitless Adapter Burial Depth: 12 feet Pitless Adapter Manufacturer's Name: B -10X Cambel Pitless Adapter Installer: Sanders & Sanders Well Disinfected Upon Completion? ® Yes ❑ No Method of Disinfection: Recire Comments: Pump Installer Name: Aarow Pump & 11'ell Service LLC PO Box 110496,Anchorage, AK 99511 (907) 346- 9355 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. 0■11Dee 28 09 04t03p 243-4730 p.1 ti ■ Pt') Box 11.32 19 .Anchortttro. AK. 995// Phan (907) 243-1720 Piu (907) 243-4730 Gamess Engineering Group Aon Jody nis is to let you know that the septic system or (lift station) at lot 2 block - Ranna. that we hooked up in November is hooked up according to NEC axle, Anchorage code and manufactures paper work by a licensed Electrician If you have any gwdionv playsc give the office a call Y ams Kwn Metric Inc. 9-.2C-01 -=- /0:01 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water B Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Date Issued: Aug 20, 2009 Expiration Date: Aug 20, 2010 Permit Number: SW090155 Parcel ID: 041-032-13 Legal Description: RANNA LOT 2 Design Engineer: 0855 GARNESS ENGINEERING GROW Site Address: NHN Owner Name: JIM JACKSON Lot Size: 0 SO. FT. Owner Address: 7040 MONTAGNE CIRCLE Total Bedrooms: 0 Permit Bedrooms: 3 ANCHORAGE,A - This permit is for the construction of: ❑ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907)343-7904(24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. Permit includes waiver WR090049 allowing the drainfield to be located 1' from the west property line and 35' from a slope >25%. Received Issued gy Date: 2 0 0 / By Date: g�d Municipality of Anchorage P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 http://www.muni.orglOnsite Development Services Department On -Site Water and Wastewater Proaram p�enr V � Q- n w llepartment 9c** VARIANCE/'VVAIVER REVIEW **** WR#: 090049 HAM PID#: 041-032.13 Legal Description: Ranna. Lot 2 Engineer: GEG Applicant: Jim Jackson Permit#: SW090155 Your request for the waivers listed below has been approved. 1. 1 foot horizontal separation from the absorption field to the west property line, 2. 35 feet horizontal separation from the absorption field to a slope greater than 25%. This waiver approval applies to the waivers listed above only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ............................................................................... Waiver is Granted: X Waiver is not Granted: Date: 0202009 Approved b . Name of Re iewer ....................................... 0.008 ................. ........ ........ Rec#: 004237 Amount: $200.00 Date Paid: 6114109 **** VARIANCE/WAIVER REVIEW **** Municipality of Anchorage • .� Development Services Department Building Safety Division 4° %' On -Site Water & Wastewater Program ' 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. Oct It' O 3 '� - 1,-7, Property owner(s) JIM JACKSON Day phone 830-6767 Mailing address 7040 MONTAGNE CIRCLE *ANCHORAGE. AK Site address Legal description (Sub'd, Block & Lot ) RANNA LOT 02 Legal description (Township, Section & Range) N/A Lot Size Sq.Ft. THIS APPLICATION IS FOR (®all that apply): Absorption Field Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well Water Storage ❑ Zip Code Number of Bedrooms 3 THIS APPLICATION IS AN: Initial Upgrade ❑ Renewal ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. Permit/Rush Fees: S16 +') c) n Date of Payment: eel Y/ U c1 Receipt Number, 00 y"n (Rev. 11/03) Waiver Fees: e� e o Date of Payment:OI'l- i q Receipt Number. a d 7 ;� _; a GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS v, - - —-- August 12, 2009, Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907)343-7904 Ref: Proposed Well & Septic System for Ranna, Lot 02 To whom it may concern: The subject lot is currently undeveloped and has no water or sewer service. The property was formally part of Atelier #1, Tract 213-1 but has been subdivided and is now known as Ranna Lot 2. The owner is planning to build a three (3) bedroom house on the property that will be served by a septic system and well. We are proposing to install a 1500 gallon S.T.E.P tank with Quanics controls/floats, a 650 Aerocell Unit and a 10' by 25' bed type drainfield consisting of 2 lines. One test hole was excavated on the property. The drainfield is designed around the 30 foot radius of the test hole. We are also proposing to have a well drilled on-site to serve the proposed house. Attached is a site plan showing neighboring lots and separation distances from the proposed well. Comments regarding the design are summarized as follows: We are unaware of any adverse impacts that the well and septic would have on any neighboring wells or septic systems. 1. SOILS: See the attached log which shows the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are surface waters on the east end of the property. The septic system is located outside of the 100 foot setback of the water. A registered land surveyor will be required to flag the prior to construction. 4. TOPOGRAPHY & WAIVER REQUEST: As can be seen on the attached topography drawing the average topography around the drainfield site is a relatively flat. The proposed drainfield will be 35' away from the top of the cutbank (40% slope). In this case we are requesting a 35' waiver be granted from the drainfield to the cutbank. As can be seen on the attached drawing, at a 25% slope (starting 2 feet above the drainfield) the potential point of daylighting is greater than 50' horizontally from the bed. 3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507-1259 Ph: (907) 337-6179' Fax: (907) 338-3246 • Websitc: www.gamcsscngincering.com 5. LOT LINE & CUTBANK NVAIVER: We are requesting a I foot lot line waiver to the west lot line. There arc is no septic systems within ten feet or twice the effective on the adjacent property. We are unaware o any adverse impacts this installation would have on adjacent wells or septic systems. If you have an tions, please contact us at 337-6179. Thank you for your assistance. Sinc ely i ,[rditc m - L, M.S. Presid NOTE: ached is a sire plan drawing, a design drawing, one soil log, which are all part of the design package for this septic system. (Contact C.E.G. Ltd. for 7 page construction specification letter.) 3701 E. Tudor Road, Suite 101 ' Anchorage, AK 99507-1259 Ph: (907) 337.6179 • Far: (907) 338-3246' Website: www.gamessenginecring.com I I I I I i I I I I STREAM ATELIER ILTRACT 2A L� CREEK MAINE.MEN �. I I I I 'twA• II I I i TH/T \� \ PROPOSED I v SEPDC SYSTEM i TH/2 1 / RANNA LOT 2 �� I I I HOUSE L PROPDS�ED I l % RANNA LOT 1 WELL ATELIE MI,TRACT 211-2 I �\ 11 PROPOSED / WELL ATELIER LOT 2 ATELIER LOT 3 BLOCK ATELIER LOT 2 BLOCK S-A ---------- -- GARNLSS ENGINEL•'RING GROUP, Ltd. 11 -- - ._...-- CONSULTANTS 6 GENERAL CONTRACTORS +�+���•''� JAI L NOOK p . NRC 101 YOdkL M /1I}[ - ," • IN M FISStIL w.. PREPARED FOR: PHONE NUMBER: PACE NUMBER: JIM JACKSON 830-6767 1 OF 5 LEGAL DESCRIPTION: DRAWN BY: RANNA, LOT 02 PNB TYPE OF WORK: DATE: SITE PLAN 8/12/01 (Rw.OIM5) DRAINFIELD DESIGN: AGREE CTOOT MAXIMUM DEPTH:4.5 FEET WIDTH: 10 FEET LENGTH:25 FEET M.OA APPROVED SAND FILTER:2.0 FEET EFFECTTVE:0.5 FEET REDUCTION FACTOR: N/A ACTUAL SO.FT.: 250 NOTE THE CONTRACTOR SMALL NAVE THE WEST LOT LINES. 100' CREEK SETBACKS. AND ALL WELL RADII RAGGED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION. Doo, p S NIT PROPOSED F �S'SETBAGK \\� 1 2S Oki Po' 04 ED \�---� TERNATE -Y av, AFF j TH/1^ SrtErFMIT,TFk `\� II"\ �J \ I \\�TESTHOLE IS EOUIRED 1' WAVER V ` FOR ALTERNATE SITE \i TO LOT \ INSTALL CLEWOUT UNE �� MIDWAY BETWEEN �\ PR TRICKLING � HOUSE AND STEP TANK ,.\ \\ FILTER DANDY VALVE / �p NSTALL FCO ,�pS \ N� \ PROPOSED GALLON TANK 100' SETBACK I PROPOSED �\ HOUSE \� PROPOSED WELL / MONTAGNE CIRCLE \ — / GARNESS ENGINEERING GROUP, Ltd. * 9 cyl ., _ „.......>............ CONSULTANTS 3 GENERAL CONTRACTORS.-•+���_-••• M1 L lUIX0 OVA AME 101 • AN010RYR. AK MTor • FIIK*X OIOTITT)-FIaF • FAY (11073 ". KU9rL •••w• M•r• PREPARED FOR: PHONE NUMBER: PAGE NUMBER: • •••...... • ;••' JIM JACKSON 830-6767 2 OF 5 O�Q a ..J t A. Gar :• LEGAL DESCRIPTION: DRAWN BY: RANNA, LOT 02 PNB�Op�s, oONo TYPE OF WORK: DATE: 4�QO4OpQSIOT' PROPOSED WELL AND SEPTIC SYSTEM DESIGN 8/12/09 LETTER THAT PERTAINS TO THIS DESIGN. OF SEDROOMS:4 TO OBTAIN A COW OF THE LETTER PER DAY (CPD): 450 CONTACT GEG. BY PROCEEDING FORWARD DON RATE/S: 40 MIN./INCH WITH THIS INSTALLATION, THE ENGINEER, D APPLICATION RATE: 2.0 WELL DRILLER, CONTRACTOR AND DRAINFIELD SO.rI 225 PROPERTY OWNER AGREE THAT THEY HAVE READ THESE SPECIFICATIONS AND DRAINFIELD DESIGN: AGREE CTOOT MAXIMUM DEPTH:4.5 FEET WIDTH: 10 FEET LENGTH:25 FEET M.OA APPROVED SAND FILTER:2.0 FEET EFFECTTVE:0.5 FEET REDUCTION FACTOR: N/A ACTUAL SO.FT.: 250 NOTE THE CONTRACTOR SMALL NAVE THE WEST LOT LINES. 100' CREEK SETBACKS. AND ALL WELL RADII RAGGED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION. Doo, p S NIT PROPOSED F �S'SETBAGK \\� 1 2S Oki Po' 04 ED \�---� TERNATE -Y av, AFF j TH/1^ SrtErFMIT,TFk `\� II"\ �J \ I \\�TESTHOLE IS EOUIRED 1' WAVER V ` FOR ALTERNATE SITE \i TO LOT \ INSTALL CLEWOUT UNE �� MIDWAY BETWEEN �\ PR TRICKLING � HOUSE AND STEP TANK ,.\ \\ FILTER DANDY VALVE / �p NSTALL FCO ,�pS \ N� \ PROPOSED GALLON TANK 100' SETBACK I PROPOSED �\ HOUSE \� PROPOSED WELL / MONTAGNE CIRCLE \ — / GARNESS ENGINEERING GROUP, Ltd. * 9 cyl ., _ „.......>............ CONSULTANTS 3 GENERAL CONTRACTORS.-•+���_-••• M1 L lUIX0 OVA AME 101 • AN010RYR. AK MTor • FIIK*X OIOTITT)-FIaF • FAY (11073 ". KU9rL •••w• M•r• PREPARED FOR: PHONE NUMBER: PAGE NUMBER: • •••...... • ;••' JIM JACKSON 830-6767 2 OF 5 O�Q a ..J t A. Gar :• LEGAL DESCRIPTION: DRAWN BY: RANNA, LOT 02 PNB�Op�s, oONo TYPE OF WORK: DATE: 4�QO4OpQSIOT' PROPOSED WELL AND SEPTIC SYSTEM DESIGN 8/12/09 8/13/2009 K.D.M. '. DESCRIPTION: $; LOT 2 OF WORK: GARNLSS ENGINEERING GROUP, Ltd. OF WOR .. ..�.CONSULTANTS &GENERAL CON WACTOFS ..�+.+...�.�+..,.�. DESIGN OF QUANICS AEROCELL SYSTEM AREU FOR: PHONE NUMBER: PAGE: JIM JACKSON 830-6767 4 OF 5 .... .... .. ........ •' � �ey •.���•rness: �. •, CE -79$3 ,•',€G '�n��. ��'I3Il.y .�• c�°'v 8/12/09 OF WORK: CROSS BY: W U rn m ON U O D T7 0 rn r GARNGSS ENGINEERING GROUP, Ltd. ���CONSULiANTI &GEN ERAL CON TFACTCI E NUMBER: 830-6767 ...1 n mn UTAI" . fin m aM . � 5 OF 5 mwll= t -200 12:01PT. Frort-PRUDENTIAL JACK, IMT: '- -•'-• -�'^ Y�YI VVJ tLiV Pi7.'FOEIMEO UCAI. DEw +20TTE23M wGc I � �^R WENT OF HE& TH 6 HLJIIAFQ SOILS LOG — PERCOLATION .a s IF YES. A7 WRAT 12 p[►M7 S 13 wl"=LL 51 14 ,5 16 SB � • ii 7J czkwE VTS , A�oR7LFl,^,SYdTIt ALL [TATE MMj SAL 7:-wa IRov. QAII DATE T -M P.003/010 F-241 VVVVM TM RUN t'_rW FK FT 1—K f//6`.T1Fr trot MS 7E5T Cr3 PgFt'J�KJ to fIY tYF'�Otl ,iva�L1:. CKTE:-L%�'����~�'�% �/✓ I,I l/rnr pion P * ; a. Y a+ , M a, ^ y Ix TM RUN t'_rW FK FT 1—K f//6`.T1Fr trot MS 7E5T Cr3 PgFt'J�KJ to fIY tYF'�Otl ,iva�L1:. CKTE:-L%�'����~�'�% �/✓ I,I Municipality of Anchorage •. Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw, Street P.O. Box 196650 Anchorage, AK 99519.6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROV L FOR A SINGLE FAMILY DWELLING /1 �^ Parcel I.D. 041-032-13 COSA# n g 0 L7 ,7 1. GENERAL INFORMATION Expiration Date: .5�— P. — / 0 Complete legal description RANNA LOT 2 Location (site address) 7040 MONTAGNE CIRCLE *ANCHORAGE, AK Current Property owner(s) JIM JACKSON Day phone 830-6767 Mailing address 7040 MONTAGNE CIRCLE *ANCHORAGE, AK Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing address Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: Individual Well ■ Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ TYPE OF WASTEWATER DISPOSAL: Individual On-site 0 Individual Holding tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the information obtained from the Municipality of Anchorage riles and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, GEG, LID. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines 6 Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational fife of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the faml7y being served by the systom. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will It confer any legal right whalsoe ver. 5. DSD SIG ATURE Approved for bedrooms. Disapproved. Phone 337-6179 Date ( Z- ob�0FA �op� Qod ��-.......... _ gs�0oo ••v0 D.........[l/t ...............l Conditional approval for bedrooms, with the fllowing stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other OFgA, G`QP•••......•oyo • ON-SITE •.��'�: WATERAND ; M: WASTEWATER : PROGRAM By: Original Certificate Date: )R". 11105) Municipality of Anchorage 0 ,\ Development Services Department �l Building Safety Division s�(►^� - On -Site Water 8 Wastewater Program 'tom!/ 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: RANNA LOT 2 Parcel ID: 041-032-13 A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (Y/N) YES Date completed 10/05/09 Sanitary seal (Y/N) YES Total depth 61 ft. Cased to 61 ft. FROM WELL LOG Date of test 10/05/09 Static water level 10 ft. Well production 10 9•p -m. WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate l' 6 mg./L. Wires properly protected (Y/N) YES Casing height (above ground) 24 in. AT INSPECTION ft. g.p.m. Other bacteria colonies/100 ml. Arsenic:: N D ug./L. Date of sample: $ O� Collected by: GEG Ltd. B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 8/26/09 Tank size 1500 gal. Number of Compartments E Cleanouts(Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) YES Date of pumping J Pumper�V — C. ABSORPTION FIELD DATA Date installed 8/26/09 Soil rating (g.p.d./ft2o /bd 2_0 System type BED Length 25 ft. Width 10 ft. Gravel below pipe 0.5 ft, Total depth 2.5 ft. Eff. absorption area 250 ft' Monitoring tube YES Depression over field NO Date of adequacy test NEW Results (Pass/Fail) PASS -For 3 bedrooms Fluid depth in absorption field before test in. Water added _gal. New depth _in. Elapsed Time: _ min. Final fluid depth _ In. Absorption rate >= 450+ g,p.d• Any rejuvenation treatment (past 12 me.) (Y/N & type) NONE KNOWN If yes, give date D. LIFT STATION Date installed 8/26/09 Size in gallons 1500 Manhole/Access (Y/N) YES 'Pump on" level at TIMER in. "Pump oft" level atTIMER in. High water alarm level at 44 Datum BOTTOM OF TANK Cycles tested NEW Meets alarm & circuit requirements? YES E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main N/A Public sewer manhole/cleanout N/A Sewer /septic service line 25'+ Holding tank N/A Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line ' 1'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway. parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS •WANERJ090049 G. ENGINEER'S CERTIFICATION I certify that I have determined through field Inspections and 9 review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS 00000 J Date lZ%ZI oC) dp�e 0 COSA Fee S�J� Date of Payment 11 91 Receipt Number (Rev. 11105) Waiver Fee $' Date of Payment Receipt Number '' .. ..........` y A. arness CE -79,53 `o�'�c�oa F, t i I DRA1Nr.GE ESMT. i , ,i PLAT NO. 2005-30 47 L8 RANNA SUBDIVISION ro L10 LOT 2 68,482 S.F. J f t ¢ Oqa„S�`T4C \ \ sem•\�? 4pp� `` CR <,8 �0 L21 LINE TABLE 40.9' \ J�. .`---,f4 44�° 0, Op -.`, � L19 !� S 61.27'08"E 18.9' E5 S 19`46'40"E 6.2' COURSE BEARING' DI E7 S 62.13'09"E 74.2' L1 S 58.28'19"E 42.00' L2 N 37.14.02"E 9.80' L3 S 68.16'49"E 33.05' L4 S 81.23.270E 18.38' `. L5 N 19401.56"E 11.58' �\ L8 N 59.05'25"E 14.18' ------- f9 L7 S 67.50'01"E 12.62' L8 N 88.5145"E 55.88'----� W L9 S 05'21'41 "E 14.86' : L10 S 79.33'19"E 34.00' Ll1 S 50.08'36"E 43.88' L12 N 88.39'43"E 23.39' v - L13 S 81.27'08"E 20.80' 1e• L14 L15 S 35037'02"E 15.01' - ----------- S 51028.21"E 42.62'- --- - L16 S 15.17'51"E 14.79'°' _ 10' L17 S 62'13'00"E 35.20' Reg55.00' L-141.39' LID S 57.10'30"E 27.56' L19 N 83'16'31"E 43.66' MONTAGNE CIRCLE LL2211 S 75.03'40"E 23.28' L22 S 59058'50"E 25.20' L23 S 46.12.04"E 9.90' L24 N 72.34.10"E 27.98' COURSE ©CARING DISTANCE E1 S 79.33'19"E 1, 29.2' E2 S 5000813811E 40.9' E3 N 88.39'43"E 23.4' E4 S 61.27'08"E 18.9' E5 S 19`46'40"E 6.2' EB S 15.17'51"E 25.5' E7 S 62.13'09"E 74.2' GASTALDI LAND SURVEYING, LLC JEFF A. GASTALDI. R.L.S. 2000 E. DOWLING RD., SUITE ANCHORAGE, ALASKA 9950 PHONE 248-5454 GRID I DATE N U Ir 1t BUILDING DETAIL SCALE. 1"a20' 1 HEREBY CERTIFY THAT I HAVE SURVEYED THE PROPERTY DEPICTED ABOVE AND THAT NO ENCROACHMENTS EXIST EXCEPT AS INDICATED. IT IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, COVENANTS OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE LINES. ANCHORAGE RECORDING DISTRICT• ALASKA THIS DATE. oulk It VA a OF 44 # c# v ' 49LH ' 0 to a. 'f v % LS—I6091 �• �� r Ar as A "fesslonol V' �• 111=60' V.G. CEA k TELE COMM ESMT.