HomeMy WebLinkAboutJOHNSON HEIGHTS PHASE 2 LT 4 ohnson H ights Lot 4 #050-972-11 Municipality of Anchorage .",' Development Services Department L,,i~' Building Safety Division On-Site Water a~d Wa,t~water Pmgt'am. 4700 E,rnOre ROad ~"YO P,O, Box 196650 Anahomge, AK 99507 Page f www, oi. anohorage, al(.u~ (907) 343.7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: O$P101004 PID Number: ~9,.q'O' c~ 7~. - fl , PRESTON JOHNSON Wastewater System: [] New [] Upgrade 9805 GREENHOUSE ,STREET EAGLE RIVER, AK 99677 ABSORPTION FIELD r,,,,,,,,, Num~ror.edmome:4 ![~DeepTt*en~h r'lshatlewTmncb r'1§ad I'IMouad r=lC~ther;. LEGAL DESCRIPTION !~.2 ePDhet= ~'~'~ ' Fl, ' Ft, 6.2 Well: [] New I~ Upgrade 3.0 n. ~ Ir`uA ~",~fl~atbn (~ale, A, a, 0); Total r~pth: ~a~zl to: Total atom ~){tOl~. ~r~; .................. RIl~ Material= EXISTING PRIVATE Fi. n. ~ ~c~, ~ Ft~ ASTM 30341ABSIFBq 0 Driller: Dale Drl~ed: l~lat[~ t.N~er LeVel: il~ta~r'. Date I~talled: F~. TWEED EXCAVATING 5-'10~2010 ' Yield: ......... [ Pump SM alt: ] Ca~l~g H [~h! Above ,~'Ol, lp~l; ' SEPARATION DISTANCES [] Septic [] Holding [] $.T,E,P, r'i Other: To SepUc Absorption Li/t Holding ~ublic/l~rivate Maam'actvrer, ............ Gapaclly! ...... Tank Field Station Tank S~wer Line PREMIER PLASTICS 1300 GaL W~ 100'+ 100'+ ~ 25'+ HDPE 2 SiT. e: M~nulaGiurer; J ...... ~t L~a 5'* 10'+ ....... N/A c~. Curtain Ora,n --~-- NONE KNOWN / . ~ ~ Elec~r"Hlll~'e0tlonapan%:medbY: ...... o . BO-FI-OM OF SIDING AT POINT A S&S Engineering....... Eng~a mp Inspections per/ormed by:. IARA1 ~. Rirc. hwood Lb. Ri3ates: 1,t 5/lOI2Ol._...__.~0 Chugiak, Naska 99561 ~.~ s/~u2o~o , Development Services Department Approval ~~ Conditional Approval Date: ~' '~": PERMIT N0.OSP101004 PAGE 2 OF 4 HunicipaLi~cy oF /~nchorage DEVELOPMENT SERVICES DEPARTMENT - BUILDING SAFETY DIVISION ON-SITE WATER AND WASTEWATER PROGRAM, ~700 BRAGAW STREET P,B, Box 196650 I Anchor~9e, Atcskc 99519-66_50 ·Tetephone~ (907) 343-7904 ·www,ci,~ncho~._.~9e,c~k,u: ON-SITE WASTEWATER DISPOSAL SYSTEH AND/OR WELL INSPECTION I-~EPOR' LEGAL LOT 4; JOHNSON HEIGHTS PHASE 2 P.I.D. X0. XXX-XXX-XX LOT 3; JOHNSON S/D ..... ~~ ~"~*~c~ ~ / N //// I' = 40' ENGINEER STAMP LOT 5, JOHNSON S/D PERMIT NO.OSP101004 PAGE 3 OF 4 Plunicipaki~cy oF AnchoPage DEVELOPMENT SERVICES DEPARTMENT - BUILDING SAFETY DIVISION ON-SITE WATER AND WASTEWATER PROGRAM, ~700 BRAGAW STREET p,n, Box 196650 ·~nchoroge~ A~ska 99519-6650 ·Telephone', (907) 343-7904 ·www,ci,onchorage,ak,u: ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION F~EPOR' LEGAL LOT 4; JOHNSON HEIGHTS PHASE 2 P.I.D. NO. 050-972-11 LOT 3; JOHNSON S/D // 2v L~ LOT 5' JOHNSON S/D C~ ~ 1" = 50' PERMIT N0.OSP101004 PAGE 4 OF 4 Municipo, Litsy oF Anchoco, ge DEVELOPMENT SERVICES DEPARTMENT - BUILDING SAFETY DIVISION ON-SITE WATER AND WASTEWATER PROGRAM, 4700 BRAGAW STREET p,Iq, 3ox 196650 e Anchorcge, ALaskc 99519-6650 e TeLephone: (907) 343-7904 ·www,ci,cnchoraee,ok,uc ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION RI~POR'- LEGAL LOT 4; JOHNSON HEIGHTS PHASE #2 P.I.D. NO. 050-972-11 INLET ST1 ST2 /-GRADE = 96.1' FINAL GRADE "INSULA ~ ~_ TOP OF TANK = /] NEW ~ ~,~ I 1300 GALLON I~ - 92., [POLYETHYLENE[ ~-OUTLET = 91.9' 93.3' GRADE GRADE FINAL = 94.2' --~C01  ',, 2" INSULATION ORIGINAL = 94.2' C01=91.4' C02=91.4' MT1 =85.2' MT2=85.2' NO · WATER FOUND 78.2' B.0.H. A B ST1 55,7' 40,3' ST2 56.2' 43.4' TMT 57.1' 45,6' DBL1 56.5' 45,7' DBL2 56.7' 46,7' DV 56,8' 47,5' C01 87.0' 97,0' MT1 88.1' 97,4' C02 110,3' 131.9' MT2 110,7' 132.1' N. T. S. STAMP Permit Number: OSP101004 Tax Code Number: 05097211000 Work Type: Septic Permit Effective Dates: May 07, 2010 On-Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade to May 07, 2011 Design Engineer: S & S ENGINEERING Subdivision: JOHNSON HEIGHTS PHASE 2 Site Legal Address: JOHNSON HEIGHTS PHASE 2 LT 4 G:0057 Owner/Address: JOHNSON PRESTON R 9805 GREENHOUSE STREET EAGLE RIVER AK 995779507 Site Mailing Address: 9805 GREENHOUSE ST, Eagle River Lot Size In Sq Ft: Total Bedrooms: 70567 4 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections dudng the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:. A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: ~ Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, Alaska 99507 www. muni.org/onsite (907) 343-7904 ON-SITE SEWEPJVVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Property owner(s) PRESTON R. JOHNSON Mailing address 9805 GREENHOUSE STREET, EAGLE RIVER Site address SAME Day phone 244-1436 Zip Code 99577 .Zip Code Legal description (Sub'd., Block & Lot) JOHNSON HEIGHTS PHASE #2; lOT4 Legal description (Township, Range & Section) Lot Size 7(~: ~'~ 7 Sq. Ft. Number of Bedrooms 4 THIS APPLICATION IS FOR (~3 all that apply): Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] THIS APPLICATION IS AN: Initial [] Upgrade [] Renewal [] I certify that the above information is correct. I further certify that this application is being made for a (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number. (Rev. 11/05) Waiver Fees: Date of Payment: Receipt Number: March26,2010 ROBERT C. COWAN. CIVIL ENGINEERINg, PH: 907'694-2979 FAX: 907'694-1211 MUNICIPALITY OF ANCHORAGE Development Services Department P.O. Box 196650 Anchorage, AK 99519 REFERENCE: Lot 4; Johnson Heights Phase//2 S/D It is requested that you issue a permit to install a new(upgrade) 1300 gallon IIDPE septic tank and deep trench septic system to serve the existing four bedroom house on the referenced property. A flmv diverter vah'e will be installed to allow the existing trench to be used at a later date. A test hole was excavated and a percolation test performed. The approximate location of the test hole is located on the attached site plan. At the time ofexcavation (5/3/2005) water was found at 16 feet. After seven days of monitoring, ground water was found at 13.6 feet. We do not anticipate any adverse effects on neighboring wells, septic systems, reserve areas or drainage patterns by the installation of the proposed septic system. The construction of this system g~ll not prevent any future development on any of the adjacent properties. Ifyou~ditional information, please contact us. 15861 S. Blrchwood Loop Road.- C. huglak, Alaska 99567 / / NOlS':la NYld-3/IS Performed FoK Legal Description: Municipality of Anchorage Development Services Department Ruilding Safety Divisk~ On-Sile Water and Wastewa~er Program 470O South I~ St. P.O. Box 196650 Anchorage, AK 99519-6650 (907) 343-7S04 ,_~f,y.j~,Soils Log,- Percolation Test 1- 2- 3- 4- 5- 6- 7- 0- 10- '12- '13. ~4. 17- 18- 19- 20- SIo0e / / / / I WAS GROUND WATER ENCOUNTERED7 .~.~ IF YES. AT WHAT DEPTH? 0 S;{e Ptan Reading Da~e Gross T~neNet T~meDepth to Water Net Drop 0 ~ ~ ~. ~o,,~ ~,,~ _~ ,, COMMENTS. TEST RUN 'EI~,VE':N ~r¢ r/~.A~.~____FT S~JLTEST ROBERT C. COWAN . CIVIL ENGINEERINC, PH: 907-694-2979 FAX: 907-694-1211 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS REFERENCE: Lot 4; JOtINSON tIEIGtlTS PtIASE//2 S/D March 26, 2010 GENERAL: The scope of this project includes the installation of a new(upgrade) 1300 gallon HDPE septic tank and a deep septic trench to serve the existing four bedroom residence located on the referenced property. A flow diverter valve will be installed to allow the existing trench to be used at a later date.. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The contractor shall be responsible for obtaining any necessary underground utility locates. Unless specifically agreed otherwise, the property o~ncr shall be responsible for final grading areas subsequently depressed from soil settling. Contractors installing wastewater disposal systems must be certified by the Municipal Development Services Department or ADEC if required, for system installations. Owners installing their o~x~ systems must also receive prior approval from the respective agency. SEPTIC TANK INSTALLATION: A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. All tIDPE septic tanks are required to have a 4" monitoring pipe installed next to the tank extending to the bottom of the tank. 15861 $. Blrchwood Loop Road - C. huglak, Alaska 99567 Page 2 Lot 4; Johnson Heights Phase #2 S/D March 26, 2010 The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. Septic tanks installed with less than 4 ft. of cover shall be insulated. All HDPE septic tanks are required to be covered with a minimum of 2" direct burial insulation, and a maximum of 4 feet of cover. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than I0 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toxvard the septic tank. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCtl/DRAINFIELD INSTALLATION: Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (rafted-up) before gravel (sewer rock) placement. Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the. distribution pipe to provide a minimum of 2 inches of cover over the pipe. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion ofthe monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert ofthe distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. Page 3 Lot 4; Johnson Heights Phase #2 March 26, 2010 MINIMUM MATERIAL SPECIFICATIONS: Any septic tank proposed for installation must be constructed by a Municipal approved septic tank manufacturer. o The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type ofpipe other than listed above must be approved by the inspecting engineer. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Feruco, or equal). A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. e When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements, which ever requirement applies. Page 4 Lot 4; Johnson Heights Phase March 26, 2010 INSPECTIONS: Typically them will be a minimum of three (3) inspections required during the installation of the wastew~ter disposal system. These inspections will occur as follows: The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any grovel. A septic tank may be set in place, but may not be backfilled before this inspection. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement ofany other backfill. 3. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre- construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests gSth the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions &the contractor or any other persons performing work on this project or the failure &the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR / INSTALLER 05/06/2010 NAM5 MAI LING ADDRESS LEGAL DESG~IPT1ON-- -- , 10:39 9076941211 SNSENGINEERING PAGE ei/el '_.. _ ALTH&ENViRON~4EN~ALPROTECTiON I ~_ / ~ ENVIRONMENTAL ENGINF~n~'~;~ ~,'~',~ ....... ~ ~ ! / 'i iLiq- c ,*¢it¥ -- DIS'EANCB TO: Inside ~ngth Dwel!ing Width Crib iWeil /