Loading...
HomeMy WebLinkAboutSNOWCUP LT 2Snowcup Lot 2 #015-321-36 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page 1 of 3 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM ANDIOR WELL INSPECTION REPORT Permit Number: I~H01002 PID Number: 015-321-36 Name: John Haomeier Builders Wastewater System: [] New [] Upgrade Address: 2204 Cleveland Ave, Suite 201 ABSORPTION FIELD Phone: Number of Bedrooms:  [] DeepTrench [] Shallow Trench [] Bed [] Mound [] Other: LEGAL DESCRIPTION So, Rating: Total Depth from original grade: 1.0 GPD,Ft2 10.5 Ft. Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: 2 Snowcup 3.5 Ft. 7.0 Township: Range: Section: Fill added above original grade: Gravel Length: 0 Ft. 55 Ft. Well: [] New [] Upgrade Gravelwidth: Number of lines: I Distance between lines: 2.5 Ft. 1 Ft. Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material: ,,C>~ i V'/3-r~ 141 Ft. 141 Ft. 770 Ft2 3034 PVC Driller: Date Drilled: Static Water Level:Installer: Date Installed: Alpine Drilling 611312010 95 Ft. John Ha[imeierBuilders 10/30/2010 Yield: I Pump Set at: ~ Casing Height Above Ground: 20 GPMI { ~'~ ' .Ft. 2.0 Ft. TANK SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other: T~ TO Septic Absorption Lift Holding >ublic/Private Manufacturer: Capacity: ,rom~ Tank Field Station Tank Sewer Line Anchorage Tank 1500 Ga~. Material: Number of Compartments; we,, 116.9 186.0 104.1 Steel 2 Sur~eceWater 100+ 100+ ~ / LIFT STATION Lot Line 57.9 33,52~ Size: Manufacturer: Gal. Foundation 12.4 82.7 "'Pump on" level at: "Pump off" level at: in. High wateralarm at: Curtain Drain NIA N/A Pump Make & Model Electrical Inspections performed by: Remarks: BENCH MARK Location and Description: Garage Finish Floor Assumed Elevation: 100.0 Ft. Engineer's Stamp Inspections performed by: PANNONE ENG. SVC, LLC Dates: 1st 10/29/2010 Development Services Department Approval . ~.. Conditional Approval Date: ~ Reviewed and approved by: Date: /¢/~/~0 (Rev. 04/06) / - ~,~17~ ~'~'--.... '7 .i:~." .... "so FO 4.6 46.6 u :' ,,i,;'! ,-" ................... <:(, . "~"-'"., T1 ~5 a 4a.3 ';' ;. |." % ' ~ '-, ",, '", ~ * T2 22.4 52.4 /~ , ..~ , ), , , .,, -,. ,' ,"~,~l"l ~.~ .... ' .......... ~X ' '"' ~' "' [ '~' ' DC 31.6 57.6 ./~ ;' ........ 'k ..... "~ ' ',., ".L':' ..' Cl 84 0 109 4 / [ '"~ :'ExIsT:'~ ~" ....... , X'"'. "" ~'. WELL ' ' 488 40.2 ; ~1 / I ~/ ~, ~ "-, ...... WITHIN 200 .OF,PROPOSED SYSTEM.,," ./: ~ : ~m~ ~./ ~~,g ............. " ; ':~ I ...... / i & /, /~. Z,,N ......... ~RESERVE DRAINFIELD LOCATON :: r ...... LOT ~ / / ~ ~ '~ c~_-~./~ .... ~' ~u~'mxZ~'w ~o.~'~D ~ ~ ' / ' / _/ ~ /22,1r'~ ~ ~ I ! ~ / , [ /~ ~ / ~' ~'~~'~ ] ~NEW PRIMARY DRAINFIELD INSTAL ':'~ I t /v ...~.t.. V '~~ ', ~L~x~'~Ox~.~'w,~o.~'~o 'l: EXgT'O ~ / / /', ;, I EXST'G: .. :', :' i .' ; ~"1 .. ' ' ..~ " ," ..' ,..., ...-..., .......... ....., I I : ; . - ...~.~ .... ,, : ~-~ ---~ ~__ _~/. ........... / .. ,. ,' : 'x ', '. ~ ,> / i " ~ , xx T. ~- X :,~ ~ ~ ~ .."' ~ : x,x ; ~ :// ~ X I.."' M,EXIS' G ~ ,,' n ~EXIST'G I ,~' i ~ ' H ~SEPTIC ~,'~ . ~'' ' " sE AF'.EA / ~// WITHIN 200/ Oy ~RaPdSED SYSTEM. ~:~ ~ ,' .; ': ,,, ;PTIC .,' NO PRIVATE/O~ ~O~MONI~ WELLS NO,' P~RI'VATE~: OR .CbMMUNI~ WELLS ', ~ :,' ~ X ~ ~ ',, ~ I~HiN 200" 0.¢' PROPOSED SYSTEM. NOTES: P~O~ ~G ~C, L~ ~: ~ RECOR~ DRAWING P.O. ~OX ~002~7 ANCHORAGE, AK 995~0 ~.. Scale PHONE (~07) :7:-~:~ FAX (~0~) ~-~:~ ~...'~~ "~"~'...'~ ~"=~o' Jo~n M~eie~ Bu~,de~ .~~~go~-~:~ 2206 Clevelomd Ave, Suite 205 r~a~-. CE 81~ '~ PER~IT NO. f~:qpZ .5~ OSP101002 PLAN Anchorage, AK 99505 ~.uZ~. ~i- ?~ ....... ,:~ Sh~ ~ ~OES9B~ SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS. 2. ALL WORK SHALL BE IN ACCORDANCE WITH THE A'FI-ACHED SPECIFICATIONS. 5. SCOPE OF WORK: 5-BEDROOM HOUSE, NEW 15009 SEPTIC TANK, NEW DRAIN FIELD. 4. GROUNDWATER IS NOT EXPECTED TO BE ENCOUNTERED DURING EXCAVATION, AS EVIDENCED BY THE SOIL TEST HOLE INFORMATION ABOVE 16 FT. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 10 FEET BELOW EXISTING GRADE, NOTIFY THE ENGINEER IMMEDIATELY. 5. CONTOUR INTERVAL=4 FEET. BASED ON MoA MAPPING DATED 1999. PRIMARY FIELD RESERVE FIELD -1.5-- 3i5' 0.5' 5 J//~ Drain rock 6" above pipe swSM~,J~ i~4~v -3..' -- j ~ .3 "diam. drain pipe J 77.3 j~j~"--Drain rock below pipe inv. -17 ~ 70.8 NO groundwoter SECTION monitored o u JO J SEPTIC TANK == .............. PROFILE DESIGN PARAMETERS ABBREVIATIONS LEGEND UPGRADE SEPTIC SYSTEM CU COPPER --w w WATER LINE/ NO. BEDROOM: 5 (750 gpd) DIP DUCTILE IRON PIPE WELL RADIUS TANK SIZE: 1,500 gallon TH TEST HOLE PERC. RATE: 1MPI FC FOUNDATION CLEAN OUT --ss ss- EXlST'G SEPTIC SOIL RATING: 1.0 gpd/SF T# TANK CLEAN OUT NO. AREA RQD: 750 SF SYS. TYPE: TRENCH, 7'ED, C# CLEAN OUT NO. ss ss NEW SEPTIC MIN LENGTH: 53.5 LF M# MONITOR TUBE NO. USE: R.I. RIGID INSULATION 0 CHAINLINK FENCE 55LFx2.5'WlDE, 7'ED, 10.5' TD DCO DOUBLE CLEAN OUT TOTAL AREA: 770 SF DV DIVERTER VALVE FS FLOW SPLITTER NOTES: PANNONE ENG SVC, LLC RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510 .. .... · NTS SNOWCUP S/D Lot 2 ~ -015-321-36 John Hagmeier Builders rlj..~"~..~even~E~a2nt?~e,~ PERMIT NO. 2204 Cleveland Ave, Suite 201~'~- ~' ~'-~ "<"~"'l'~,?p/~... ..~_~N~.~ 0SP101002 DESIGN NOTES Anchorage, AK 99505 ~li?'-~?~:.~{~:~.~ Sheet INOV U~ IU Ul:~bp dor~n I-lagmeler Homes 9072486434 Alpine Drilling & Enterprises Well Log Permit Number: #SWOSP 101002 Date of Issue: 5-5-10 Parcel Identification Number: 01532130000 Date Started: 6-~2-I0 Date Completed: 6-13-10 Is well located at approved permit/ovation? x Yes [] No Legal Description: Snowcup Lot 2 G2538 ~ Property Owner Name & Address: Saleeby Becky & Ream Bruce ' -' 3421 Spinnaker Anchorage, Alaska 99511 Borehole Data: Depth (ft) SoiI T~pe, Thickness & Water Strata From To Stick-up 0 2 organics 2 3 sandy silt 3 t O grin, oily silt 10 , 26 silty gray'el 26 I31 gravelly silt 131 137 ·vater sand & gravel t37 141 Method of Drilling x air rotary' [] cable tool Casing type: steel Wall Thickness: .250 inches Diameter: 6 inches Depth: 141 feet Liner Type: ~ Diameter: ~ inches Depth: ~ feet Casing stickup above ground: 2 feet Static water level (from ground level): 9_&5 feet Pumping level: 141 feet after 2 hours pumping 2_Q0 gpm Recovery Rate: 2_0_0 gpm Method of Testing: air lift WelI Intake Opening Type: x Open End [] Open HOle [] Screened" Start ~ feet Stopped [] Perforations Start ~ feet Stopped__ feet feet Grout Type: bentonite granules Start 0 feet Pump: Intake Depth __ feet Pump size __ hp Brand Name Volume: 2bgs Stopped ? feet Well Disinfected Upon Completion? x Yes [] No Method of Disinfection: chlorine tab/ets Com melllS; ~Vell Driller: Alpine Drilling & Enterprises PO Box ] 10496 Anchorage AK 99511 Mark Begich Mayor Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Elrnore 5treet P.O. Box 196650 Anchorage, AK 99519-6650 www. muni.org/onsite {907) 343-7'904 Pump Installation Log Well Drilling Permit Number: S Date of Issue: Parcel Identification Number: _ Replacement Only: YES NO Legal Description Property Owner Name & Address: Pump Installation Date: Pump Intake Depth Below Top of Well Casing: ~ feet Pump Manufacturer's Name: Pump Model: ti~ Pump S~e ~ hp Pitless Adapter Burial Depth: ~ feet Pitless Adapter Manufacturer's Name: Pitless Adapter Installer: ~ ,~h:~~ ~; ~ ~?~*~,~ Well Disinfected Upon Completion? ~ Yes ~ No Method of Disinfection: Comments: Pump Installer Name: Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. Permit Number: OSP101002 Tax Code Number: 01532136000 Work Type: WellSeptic Permit Effective Dates: May 05, 2010 On-Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Initial to May 05, 2011 Design Engineer: PANNONE ENGINEERING SERVICE Subdivision: SNOWCUP Site LegalAddress: SNOWCUP LT 2 G:2538 Owner/Address: SALEEBY BECKY & REAM BRUCE 3421 SPINNAKER ANCHORAGE AK 995163424 Lot Size In Sq Ft: Site Mailing Address: Total Bedrooms: 58427 5 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Pdvy Y Pdvate Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction dudng freezing weather must either. A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By:~ Issued By ~ Date. x,.~// c~'///(~ Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.org/onsite (907) 343-7904 1007. ON-SITE SEWER/VVELL PERMIT APPLICATION FOR a SINGLE FAMILY DWELLING Parcel I.D. 015-321-38 Property owner(s) John Haqmeler Co Mailing address2204 Cleveland Ave, Suite 201, Anchoraqe, AK Site address I0~01 ~l~c~ R,~ Legal description (Sub'd., Block & Lot) Snowcup S/D, Lot 2 Legal description (Township, Range & Section) Lot Size 58427 .Sq. Ft. Number of Bedrooms 4 Day phone Zip Code 99503 Zip Code THIS APPLICATION IS FOR (~;~ all that apply): Absorption Field Septic Tank Holding Tank Privy Private Well Water Storage THIS APPLICATION IS AN: Initial [] Upgrade [] Renewal [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. Pannone Engineering Services, LLC (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: (Rev. 1 lj05) Waiver Fees: Date of Payment: Receipt Number: Pannone En§ineerin§ Services LLC Steven R. Pannone, P.E., Principal Licensed & Registered in Alaska and Florida E-maih ~;t~ve~panenRak.~om April26,203.0 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road P. O. Box :3.96650 Anchorage, Alaska 99519 Re.' Snowcup S/D Lot 2 Well and Septic System Installation Ladies and Gentlemen: I am writing to request that a permit to construct a new well and septic system be issued for this property. The proposed systems will serve a proposed four-bedroom house. The lot is not currently developed. The proposed scope of work is to install a new 1250 gallon septic tank and absorption system along with a new private well that will serve this lot. Solls Investigation: A soils exploration was completed in August of 2007 by BTH Construction The soils encountered were clean well graded sand in the area where the new drain field will be installed. The percolation rate of the soil based on the test performed is faster than I rain/in, the soil has sufficient sand content as to no warrant the installation of a sand liner. Bedrock and ground water were not encountered in the test pit. Ground water was not observed after the water monitoring period. Based on the soil investigation and the water monitoring performed to date, I believe the best system would be a conventional septic system using an application rate of 1.0 gpd/sf. Trench Deslgn: a. Percolation Rate: <3. min/inch b. Application Rate: 3..Ogpd/sf c. Numberof Bedrooms: 4 d. Design Flow: 600 gallons per day e. Min. Absorption Area: 600 sf f. Totaldepth: 10.5 feet g. Effective Depth: 7.0 feet Mailing: P.O. Box 3.00217, Anchorage, AK 99510-0217 Physical: 615 East 82"~, Suite 86, Anchorage, AK 99503 Telephone: (907) 272-8218 FAX: (907) 272-8213. Page 2 of 2 h. Width: 2.5 feet i. Reduction Factor: - j. Minimum Length: 42.8 feet k. Design Length: 50feet I. Effective Absorption Area: 70Osf m. Septic Tank Size: :1250g steel Septic tank Surface Water: There is no surface water within 200 feet of the proposed installation. 4, Topography: The average topography in the area of the proposed septic system is approximately fifteen percent to the southwest based on MoA Mapping 5. Future Development: The proposed installation will not affect the future development of the surrounding or existing lots. There are no wells or septic systems within :100 feet of the proposed septic location. 6. Drawing Marking: The Drawings are marked "For MoA Review Only". When written notification that the review is complete and that there are no further comments is received from MoA On-Site Department, the note will be removed and "issued for Construction" drawings will be issued. If you have any questions or concerns, please contact me at 272-8218. Sincerely, Steven R. Pannone, P. E. Principal s/s/ o Attachments: Mailing: P.O. Box :100217, Anchorage, AK 99510-O217 Physical: 615 East 82"d, Suite B6, Anchorage, AK 99503 Telephone: (907) 272-82:18 FAX: (907) 272-82:11 · I~-----.-.__ ' '"::-~" ,:\ '"-. / ,' >~'L.I ~ __ -...'\ '-. "-., ...... . / .- ..\ .. .~.....- ~ ,'.1 ............... ~-"--,, '-,'-\"-,. '., , ,- ,, I ./ .," V" ,..-", · "" I' ~ "'-. '"~'-",." . ' ,' I .' ..., _.~ ... %,-........,. ... ,, i .. f X ,. '~ , ~ .......... %. ',~ ~ ',, .. .....~.~.' ,, ,, : . .' ,.,. ~ ,' ,, ,,~, .- .. .... ~o~....~ , ;.~] I.' ~ '"-.. V'. '-.,- ...... I , ; ,.'X ..' /. :~ I .............. ~ ....... ~ '.. '- ... ,I ' ,' ; ,. ~ ,, ,- · ' ~ ~EXIST'G ~ ..... ~ ~".. ',.. '"'NO PRIVATE O~ COMMUNI~'WELLS~ ." .' ' 1. // ~dd - ~ " ~ ,,, ' ..... WIT~ 200 QF PROPOSED SYSTEM.~ ,, ' I I~ I ~ '- '"-.. I " ; ."~' ' I~1 ~ ;' ~ ~ ~TH4 %,/ ""- ' ..... I ..'' .' , ',., _..: ~'~ '/ -.... ........... , . ~...' :' ' LOT A / / ~ ~x~s~ ~o~os~ ~-.- : ~', i / ' /~ ~ / SEPTIC /RESERVE oRa~,q~LDS , I ~ / ,..'~'-... / :~ 1 %/ // / ' ~,. :, ~1 / / ~ 27.~JH~ t EXiST'G~ ~:, ;~ / .., ../<':~.~'.. ~,~,~ x' · -~ : / ,: ,:1 y ~, %~ -.. ......... .' ' ,~e~ & ,, . .~--- - ,....../ ~ ~:~.~ .~. , ~.. ....... ~ , .. .~ ~ ~~~" ~ ~ : ....' '1' I /,,- ' ~-, E I ,- .' '., ....... ,,"'% Z: ~:~~,,o~os,~, ~ .... .. :,"l /..'~~: ¢~.~?p~'l ~ ~ ~2so~ ..... ...' ..' ,' ~ I ,.l:'~ ~~:~ ~E~us~., ...... ~) I SEPT~CTAN~ ,, ,." ., .. , '7 / ~ ...... /:/~: ~ ~ ..- ..' .. '.,.;,/ (.-~ ,,-1/~.: ~ ~,., .,,- ,. ,,. ~ ~ V ~~/.--' ~'-.-...- . ......... .-..~ .,' ; , ,: h X ~:/ ~/ .~" ~ ~ '~ ...... ' ' " I : -' -- ~.~' ~~~~/~ ....:--.. ,..,, /Z >~ ......... f~ ......... '~7 ...... ~:-~ j ~-~ : : ~EXISTG ~ ~ ~ ; J L : , ,,." .,' /AREA ~"~ ; ' .." :E) IST'O " ~ ~ I t" "' .... [,' , , , : ... ~S~PTIC , NO PRIVATE ~: i '. ..' /*l ~ ~" ~IT.~N 200' ; i; ~ ," , ,.' i i ~ '. ', ~O P~ATE~,OR dOMMUNI~ WELLS ', -" I ~ ~ .: . ~,T~ ~oo or ,Ro.os~ S~S~E~. " .-"' i ~ ~ ~' ~ .... /,~, . .- .... ." .o~,s: ~O~ ~G ~C, L1~ ~. ~/~/~o ISSUED FOR CONSTRUCTION PHONE (907) 272-82~8 FAX (907) 272-8211 ~.. ~... ~ ~ ~ ~. ~. ,'~o' ~ '' ~ ...... ~ P.I.O, NO SNOWCUP S/D Lot 2 John Hogmeier Builders ' ~~o~n~' ....... ' PERMIT;iS-321-3~NO. 2204 Clevelond Ave. Suite 201 ~ ~.. ~ sw~,~ PLAN Anchoroge, AK 99503 ,~ ~'- .~ ~ 1 Or 2 SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS. 2. ALL WORK SHALL BE IN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS. 3. SCOPE OF WORK: 4-BEDROOM HOUSE, NEW 125Og SEPTIC TANK, NEW DRAIN FIELD. 4. GROUNDWATER IS NOT EXPECTED TO BE ENCOUNTERED DURING EXCAVATION, AS EVIDENCED BY THE SOIL TEST HOLE INFORMATION ABOVE 16 FT. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 10 FEET BELOW EXISTING GRADE, NOTIFY THE ENGINEER IMMEDIATELY. 5. CONTOUR INTERVAL=4 FEET. BASED ON MoA MAPPING DATED 1999. --b ~'j- - SECTION - / PROFILE DESIGN PARAMETERS ABBREVIATIONS LEGEND UPGRADE SEPTIC SYSTEM CU COPPER w w WATER LINE/ NO. BEDROOM: 4 (600 gpd) DIP DUCTILE IRON PIPE WELL RADIUS TANK SIZE: 1.250 gallon TH TEST HOLE PREC. RATE: 1MPI FC FOUNDATION CLEAN OUT ss ~s ~ EXIST'G SEPTIC SOIL RATING: 1.O gpd/SF T# TANK CLEAN OUT NO. AREA RQD: 600 SF SYS. TYPE: 'fRENCH, 7'ED, C# CLEAN OUT NO. ~ ss ss ,, NEW SEPTIC MIN LENGTH: 42.8 LF M# MONITOR TUBE NO. USE: R.I. RIGID INSULATION O CHAINLINK FENCE 50LFx2.5'WIDE, 7'ED, 10.5' TD DCO DOUBLE CLEAN OUT TOTAL AREA: 700 SF DV DIVERTER VALVE FS FLOW SPLITTER .o ss= PANNONF ENG SVC, I.IC t, 5/5/,0 P.O. ,ox ,oo2,7 Scale ISSUED FOR CONSTRUCTION PHONE (907) 272-8218 FAX (907) 272-8211 ~r~.,'~49TH..~ '..llr~/, NTS ~,--~, ......"'/.~ ~.Lo. NO SNOWCUP S/D Lot 2 ~.~,.~.115-321-3( John Hagmeier Builders'¢ %;~,¢~"~"' CE 8149 .,~,.'~' ~ERMIT NO. 2204 Cleveland Ave, Suite 201 h ~'~.. , . ....~,~.,~ sw~ DESIGN NOTES Anchorage, AK 99503 ~i¢,,~.¢A.~,;~? Sheet ,~,~%%.~.~-~ 2 OF 2 f"', Municipality of Anchorage Development Services Department Soils Log - Percolation Test TEST HOLE #5 p~d~m~d~ SXX-M CEDAR HOMES LOT 2, SNOWCUP SUBDIVISION S~pe VEGETATION BROWN, SANDY SW - CLEAN, WELL GRADED SAND ENCOU~ITER£ O? NO . C:)CPT. TO W.,,TL. ~/A__ DATE; 08-03-07 SEE ATTACHED SITE PIJ%N : LEVEL 13-- 14-- 07-26-07 TEST HO: R ACCEPTEr 5 GALLON£ OF WATER WITHIN 5 MINUT] ~ ON TWO SUCCESSIVE ATTEMPTS. PERCOL~ ION RATE IS GREATER THAN I Mill/IN, HOWEVER rile CONSI.~TENCY OF THE NATIVE SAND WILL PRECLUD] TIlE USE CF AN IMPO}TED SAND .[NER. PERCOLATION RATE >1 MIN~INCH T~ST HOLE DIA. 6 INCHES) TEST RUN BETWEEN 5.0 FT AN D .._6_...Q _ FT A FOUR HOUR PRESOAK WAS PERFORMED; [] YES ~ NO COMMENTS: THIS DATA IS FOR EXCLUSIVE USE BY BTH CONSTRUCTION, LLC TO DEMONSTRATE THE VIABILITY OF THE SUBJECT PROPERTY TO SUPPORT AN O,~-SITE SEPTIC SYSTEM. PERFORMEDBY:DTtl CONSTRUCTION. LLC I, BRIAN T. llARTEN ,CERTIFYTI-IATTHISWASPERFORMEDINACCORDANCEW1TH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: AUGUST 3 r 2 0 O 7 1A9 � • Municipality of Anchorage ��5 6 " '�>>, °` _.. , i f i..r On-Site Water&Wastewater Program ,...(V i� �0 < • 1i 46 (907)343-7904 X SA "" II- h,.'-„� f1 6 �Q CERTIFICATE OF ON-SITE SYSTEMS A'''.4 CI C;1 Parcel I.D. 015-321-36 Expiration Date: Cr^ 12 -1 9 1. GENERAL INFORMATION Complete legal description SNOWCUP S/D; LOT 2 Location (site address) 10501 BIRCH ROAD, ANCHORAGE,AK 99516 Current Property owner(s) BECKY SALEEBY Day phone 223-2967 Mailing address SAME AS SITE ADDRESS Real Estate Agent SABRA GILLILAND Day phone 720-7404 2. TYPE OF DWELLING: U Single Family (w/wo ADU) ❑ Duplex U Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 5 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well I. Individual On-site III Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for N/A Distance: - Received by: Date: COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee$ 55 Waiver Fee$ Date of Payment a/2//9 Date of Payment Receipt Number 0&,611q6) Receipt Number COSA# Q 5o9to(p‘ Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD, SUITE 101 *ANCHORAGE,AK, 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date 3l$//q Engineer's Comments: In conducting this evaluation,GEG provided an engineering evaluation of the well and/or septic system in accordance with the �t*'I**y guidelines and regulations established by the Municipality of Anchorage and industry practices.The reported results describe the *4 OF A/1'tr, condition of the sysiem/s on the date/s of the evaluation.Separation distances were measured to readily identifiable features. .. ,9 Hidden defects or encroachments may exist that were not identified during the evaluation.The operational life of all wells and septic '•�••••••,•,••••/• •.. ,♦�. systems depend on a variety of variables including,but not limited to,soil conditions,groundwater levels(that may fluctuate during ,' / ' �•• �. • the year),quality of construction(materials and workmanship),and the water usage of the family utilizing the systems.These / * •• conditions can vary,and are outside the control of GEG.Satisfactory test results do not guarantee future performance of the 49 I' \ * •I/ system/s,therefore,GEG makes no warranty(express or implied)regarding the future performance of the well or septic system. / GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the 0••, ,� I ••. current systems fail.The content of this report is for the sole benefit of the person/party who retained GEG.Reliance upon the •�;••• / information provided in this report by any other person or party,including but not limited to subsequentproperly / . A79Gam ss �v eq rPurchasers,israt �1•c C -79 ��- authorized.In short,GEG disavows any legal duty to anyone other than the person/party who paid for this report. �i,• ( j / • 6. DSD SIGNATURE p p 4 LICENSE ,,�1,;"`ai4.4 l System #1 Approved for S bedrooms. #AECC884 System #2 Approved for bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipul$tions: G. ON.S\ o SSPIERWP GRAM .c) PRO " oo"�nit ss 9" � By: r \A', �! "-N'ge_ Original Certificate Date: 3 - t2'( q The Municipality or Anchorage Develop,emt Services Division(DSD)issues Certificates of On-Site Systems Approval(COSA)based only upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist Nitrate Advisory •• ,, , Septic System Advisory Arsenic Advisory ,� Well Flow Advisory Other (Rev.10/12/12) COSA Checklist Legal Description: Snowcup S/D; Lot 2 Parcel ID: 015-321-36 If more than 1 septic system on lot: COSA Checklist# 1 of 1 Structure served by this system 1 A. WELL DATA 0 Well log is filed with Onsite (or attached) Well production at time of test 5.7 gpm Date drilled 6/13/10 Water storage tank volume n/a gallons Total depth 141 ft Well disinfected for coliform test? ❑ Yes ❑■ No Cased to 141 ft Q Coliform bacteria is Negative ❑■ Sanitary seal is functioning correctly Nitrate 0.823 mg/L ❑ Nitrate less than MRL (ND) ❑■ Wires are properly protected Arsenic <5 ug/L 0 Arsenic less than MRL(ND) Casing height (above ground) 24+ in. Collected by GEG, Ltd. Date of flow test for COSA 3/5/19 Date of Sample 2/26/19 Static water level at beginning of test 99.5 ft. Comments B. TANK DATA „C. LIFT STATION Age of tank(s) 8+ years ❑ Fre- ' ed maintenance completed Tank type/material Steel/Sept Age of lift stab. years ❑■ Standpipes/foundation cleanout per record drawing Lift station material Date of pumping 3/6/2019 Comments: Note:the tank has 40"of cover on shallow end of tank. no freezing issues per owner(see attached email form owner). D. ABSORPTION FIELD DATA Deep Trench Which system tested (date installed) 10/30/10 Adequacy test date 3/5/2019 Q ALL standpipes present per record drawing Results E Pass For 5 bedrooms Total measured depth from grade *8.5 ft (max) Fluid depth prior to test 14.75 in Measured depth to pipe invert from grade 4.1+ ft(min) Water added 1026 gal ❑ N/A—pressurized field New depth —26.75 in ❑ Monitor tubes go to bottom of drainfield. If not, state Elapsed time 1065 min depth into effective*3.26' Final fluid depth 13.75 in • Code-required soil cover over field Absorption rate 750+ gpd ❑ System presoaked No (Required if vacant for greater than 30 days prior to Any rejuvenation treatment(past 12 months) date of test) N/A Gallons introduced N/A gallons If yes, enter date Comments/Deficiencies:*Monitoring tube does not extend to bottom of drainfield or has been partially filled with dirt.There was liquid in monitoring tube prior to test. **Liquid level was 12.75"inches below invert of west cleanout at end of adding water to system based upon field elevations taken during testing period. COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot> 100' Community Sewer Manhole/Cleanout> 100' 11 Yes if No ft Z Yes if No ft Neighboring Tank> 100' n Z Yes if No ft Private Sewer/Septic Line >25' ['Yes if No ft Absorption Field on Lot> 100' Ill Yes if No ft Holding Tank > 100' ❑✓ Yes if No ft Neighboring Absorption Fields> 100' Animal Containment> 50' Q Yes if No ft nJ✓ Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ✓Q Yes if No ft ✓]Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' * Q✓ Yes if No ft Surface Water> 100' Q✓ Yes if No ft Property Line > 5' 0Yes if No ft Driveway/Parking > 0' [✓ Yes if No, comment Absorption Field > 5' ['Yes if No ft Wells on Adjacent Lots: Water Main > 10' ['Yes if No ft Private Wells > 100' ✓O Yes if No ft Water Service Line > 10' Q Yes if No ft Community Wells >200' ❑✓ Yes if No ft From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Q✓ Yes if No ft Driveway/Parking > 0' Q✓ Yes if No, comment Property Line > 10' [' Yes if No ft Wells on Adjacent Lots: Water Main > 10' ['Yes if No ft Private Wells > 100' E✓ Yes if No ft Water Service Line > 10' Q✓ Yes if No ft Community Wells >200' Q✓ Yes if No ft Surface Water> 100' ✓❑ Yes if No ft F. ENGINEER'S COMMENTS *Septic tank is partially under low-lying deck. Deck supported by 2" driven piles. 46"+ from edge of closest 2" deck pile to centerline of tank (see attached photos). **Measured over 100'+ to heavily vegetated area on north end of Lot 1, BIk 2; Spring Forest S/D. No septic standpipes were physically found due to snow cover on Lot 1, BIk 2; Spring Forest S/D, but it is believed there is 100+separation from well on property to this septic system. o�0op,N,\ �Q 4 G. ENGINEER'S CERTIFICATION o OF � 00, I certify that/have determined through field inspections and review tl k., •. of Municipal records that the above systems are in conformance with fr.-. 9 H _...,o0 ../ MOA COSA guidelines in effect on this date. O •0 • •.Je i A. Garness V 009 , '•- r'r-79 • op 0,i' • • <eO COSA Checklist yellow sheet 4 pr°t ess i0(‘°\'= ''c ' #AECC884 Opp00o�> Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www. muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. o:~5-32x-36 1. GENERAL INFORMATION Complete legal description 5nowcup, Lot 2 Expiration Date: Location (site address) zosoz Birch Road, Anchroage Current Property owner(s) John Hagmeier Homes Day phone Mailing address Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 5 TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class ~ Public Water System Well TYPE OF WASTEWATER DISPOSAL: [] Individual On-site [] [] Individual Holding Tank I'1 [] Community On-site [] Public Sewer E~] The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on th~i~formation obtaine.d.,..,, from the Municipality of Anchorage files and from my investigation and nspect on, the ~Sr~l~.,~t~water suplAly~ah~/or wastewater disposal system is(are) in compliance with all applicable Municipal and l~tait~o.¢es, ,~r~di~s, and regulations in effect at the time of installation. %:~,~lame of Firm Pannone Engineering Services, LLC Phone 272-8218 Address P.O. Box :too2~7, Anchorage, AK 995zo Engineer's Printed Name Steven R. Pannone, P.E. Date Engineers Comments: In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MOA DSD Guidelines & Regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. PES can therefore not provide any warranty for future performance nor give any estimate of how long the system will continue to meet the operational requirements of the MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized nor will it confer any legal right whatsoever. 5. DSD SIGNATURE Approved for ~ bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory X By: (Rev. 11/05) Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program. 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www. muni.org/onsite (907) 343-7904 CERTIFICATE OF ON'SITE SYSTEMS APPROVAL CHECKLIST Snowcup Lot a Legal Description: A. WELL DATA Well type Private Date completed 6h._~lao3,o Total depth 3-4a ft. If A, B, or C provide PWSID # ~ Sanitary seal (Y/N) Y Casedto 3,tr3, ft. Date of test Static water level Well production WATER SAMPLE RESULTS: Coliform Ne_a colonies/100 mL Arsenic: ND ug/I B. SEPTIC/HOLDING TANK DATA FROM WELL LOG Parcel ID: ,. o3,~-:~23,-~6 95 ff. 2o g.p.m. Nitrate 0.627 mg/L Date of sample: ',3,191=o3,o ~ Well Log (Y/N) Y Wires properly protected (Y/N) Y Casing height (above ground) 2tr AT INSPECTION g.p.m. in. Tank Type/Material Anchorage Tank/Steel Tank size 3.500 gal. Number of Compartments_= Foundation cleanout (Y/N) Y_ Depression over tank (Y/N) N Date of pumping Pumper C. ABSORPTION FIELD DATA Date installed 3,o1~ol2oao Soil rating (g.p.d./~ or ft2/bdrm) 3,.0 GPDISF Length 55 ff. Width ,,2,5 ff. Total depth 3-0,5 ft. Eft. absorption area 770 ~ Monitoring tube Y Date of adequacy test __ Results (Pass/Fail) Fluid depth in absorption field before test ~ in. Water added ElaPsed Time: ~ min. Final fluid depth ~ Any rejuvenation treatment (past 12 mo.) (Y/N & type) Date installed ~oln_ol2o3,o Cleanouts (Y/N) Y · High water alarm (Y/N) N System type Deep Trench Gravel below pipe 7 ft. Depression over field N For ~ bedrooms ~ gal. New depth~ in. in. 'Absorption rate >= g.p.d. If yes, give date Other bacteria Neg colonies/100 mL Collected by: Pannone Engineering D= LIFT STATION Date installed "Pump on" level at~ Datum in. E. SEPARATION DISTANCES Size in gallons "Pump off" level at~ Cycles tested SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot ~.~6.9 Absorption field on lot ~.86.o Public sewer main 7~;+ Sewer/septic service line ~.~.~..6 Animal containment areas 50+ in. Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? On adjacent lots ~.oo. On adjacent lots ~.oo+ Public sewer manhole/cleanout ~oo+ Holding tank ~oo+ Manure/animal excrete storage areas ~oo+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation ~.2./, Property line Water main ~.o+ Water service line Wells on adjacent lots Property line :~.5 Water Service line Curtain drain 50+ F. COMMENTS New System . SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Building foundation Surface water Wells on adjacent lots ~oo+ Absorption field 5+ Surface water 3.o0+ Water main 75+ Driveway, parking/vehicle storage ~o+ in. I ce~i~ ..... that I have dete~ned through field ~nspections and review of Municipal reco~s that the above systems a~ in conforman~ with MOA COSA guidefi~es in effect on this date. Engineer's Printed Name Date ~1~81~o~0 COSA Fee $ Date of Payment Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number 40' O~ 0 PLAT NO. 2006-32 SNOWCUP SUBDIVISION LOT 2 58,427 S.F. .I LOT 89°54'44"E 164.76' LOT 2 . ' SEPTIC SYSTEM EXISTING BUILDING 57.9' S 89°56'~0"E 100,00' CONC.- 20' JOINT ACCESS -- DRIVEWAY AGREEMENT WELL I~ GRAVEL DRIVE 10' T. & E. ESMT. S 89°56'40"E 290.21' 49.7' 1 1"=50' 15.9' DECK 50.5' 11.0' BUILDING SCALE: 24.0' DETAIL 1 "=2.0' AS-B U I L T , HEREBY CERTIFY THAT I HAVE SURVEYED THE ............ PROPERLY DEPICTED ABOVE AND THAT NO GASTALDI LAND ENCROACHMENTS EXIST EXCEPT AS INDICATED. SURVEYING, LLC IT IS THE RESPONSIBILITY OF THE OWNER TO JEFF A. GASTALDI, R. LS. DETERMINE THE EXISTENCE OF ANY EASEMENTS, 2000 E. DOWUNG RD., SUITE 8 COVENANTS OR RESTRICTIONS WHICH DO NOT ANCHORAGE, ALASKA 99507 APPEAR ON THE RECORDED SUBDIVISION PLAT. PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA GRID DATE HEREON BE USED FOR CONSTRUCTION OR FOR 2538 11/5/2010 ESTABLISHING BOUNDARY OR FENCE ENES. ' ANCHORAGE RECORDING DISTRICT, ALASKA F.B. JOB NO. NOTE: NO CORNERS SET THIS DATE. 10-08 SCS2