Loading...
HomeMy WebLinkAboutTIMBER RIDGE BLK 2 LT 12Timb r Ridge Block 2 Lot 12 #050-321-30  () Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program, 4700 Elmore St. P.O. Box 196650 Anchorage, AK 99519-6650 Page 1 of 3 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: DSP101027 PID Number: 050-32i-30 Name: Hike Ouinn Wastewater System: [] New [] Upgrade Address: PD 3OX 77P641 ABSORPTION FIELD Phone: 694-4955 NumberofBedrooms: 3 f-I Deep Trench ~ii~ Shallow Trench i-IBed DMound I-IOther: LEGAL DESCRIPTION Soil Rating: 1,2 GPD/Ft2 Total Depth from original grade: 4 Ft. Block: Lot: Subd~'i¢ion; Depth to pipe bottom from original grade: Gravel depth beneath pipe: 2 12 um~oer' Ridge 1 Township: Range: Section: Fill added above odginal grade: Gravel Length: ?+ Ft. 47 Ft. Well: [~ New [] Upgrade o .... Iwidth: ,~ Ft. Numberoflines:l IDistance between lines:Ft' Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material: PF'ivate 305 Ft. 49Ft. 405 Ft2 PVC 3034 Driller: Date Ddlled: Static Water Level: Installer: Date Installed: Suttivan 6/4/1: 40Ft. Sanders 6/8/10 Yield: 0,8 GPM Pump Set at:f 1 Casing Height Above Ground: ~3 2 Ft. TANK SEPARATION DISTANCES I [~ Septic [] Holding [] S,T.E.P. [] Other: T~ To Septic Absorption Lift Holding )ublic/Private Manufacturer: Capacity: nom~ Tank Field Station Tank SewerLine Anchor'age Tank 1000 Gal. Number of Compartments: We, 100'+ 100"' NA NA 25'+ Material:Sfl;ee[ Su,aceWeter100'+ 100''- NA NA ~/ LIFT STATION Lot uno 10' + 10' + N A N I~/~ Size: Manufacturer: "Pump 9n" level at: ~h water alarm at: Foundation 10/+ 10/-~- NA NA ,n.~ ~,. Pump Make & Model ~lnspections performe~t~ Cu~ain Drein NA NA NA NA ~ Remarks: BENCH MARK Location and Description: Deck Assumed Elevation: Top 100Ft. E n~r~,r/~, ~amp Inspections performed b¢'l.°r'-I:hRim Engineer'ingDates: 1St 6/7/10 2nd 6/8/10 Development Services Department Approval Conditional Approval Date: /.,, -ce ~,~O ' '~*; ~'~' (.'C~ ..~ Reviewed and approved by: .? -- .......... / / Date:/¢, -';~- ~" "/O //// Z Z '° ~ I 0 --IO 0 < n~ 0 Z r~ C] -q Fq m Fq II 3 Fq < U < O II m 0 II II CO ~0 (7', 0 0 C ~ O 5'~ -5 O O H- '5 I O m r~ < 0 ~r 0 -b '3 r~ N Z~- 0 < O O D + O Well Log PennitNumber: OSP .laso2? Date of Issue st2at2o,~o Parcel ldentificationNumber: 05o3213oo0o Date Started: atari010 Date Completed: 6/4/2~0 [swell Iocatedatapla-ovcdp~rmitlocation? !X [ Section: Town: Range: Property Descr~on l~'ope~y Owner Name & Address: Borehole Data: Soil T>l~e, Thickness & Wat~ S~a G~ ~rock Grin O~y Gray & W~ ~mck TIMBER RIDGE Lot 12 BtoGk 2 MICHAEL QU1NN CONSTRUCTION Water Sample Resull~: BOX 772641 EAGLE RIVER, AK 995'7 u From To 0 2 85 114 t14 '173 173 305 Ax~cnic: Nitrates Total Coliform Bacteria Other bacteria: mg/l coionieslt00mL col;100mL Method of Orilli~ ~-, air rotary ['~ Cable tool Wall thicknas~ 0a$ inches Diamet~' 6 inches Total: 49 Liner tYl~: D~ inches D~Xh: Casi~ stick-up above ground: 2 feet Static Water Level(from top of casing) Pumpia8 Level: feet after m hours pumping g,om Recovery Rate gpm Method of Testiag: Air 40 feet Well latake Opeaing Type l Open End :x{Op~ HO{C {. Screened Start feet feet [-- Perforations Start feet £cct Groat Type: Bamo~ dry granular Vo{um~: 600 Pounds l~pth 44 Start o feet Stopped 44 feet Pump Intake Depth: feet Pump size: HP brand name Well disiifected up~l Compldio~? X~_ Yes i [ No Commeats: r OVEI~ SHALLOW BElmOCK BOJREHOL£ PROCEF..DURE$ FOLLOWED IN ACCORDANCE WITH M.O.A. SPECS. WELL PRODUCES 48 G.PJ-t. Well Oritlm-:. Cole Sullivan 18,utfiv~n Water WetL~ P.O. Box 67027~ Stooped Stopped : Attention: The property owner shall provide tills log ~o DSD (onsit~) and OlqR withla 30 days ot'complction. 1;8 ARCTIC PUMP & WELL INC. Jim Sullivan PO Box 770~ 97 Eagle River, A_K 99577 (907) 688-2510 (907) 258-2510 (907) 745 -2510 Pump Installation Log Well Drilling Permit Number: Parcel Identification N umber: osp101027 05032130000 Date Of Issue: 5/26/2010 Legal Description: Timberidge B2 L12 Lot: 12 Block: 2 IProperty Owner Name Address: Quinn Constuction PO BX 772641 Eagle River AK 99577 Pump Installaion Date: Pump Intake Depth Below Top of Well Casing 10/5/2010 283 Feet Pump Manufacturer's Name Pump Model: Pump Size: Pitless Adapter Bu rial Depth: Pitless Adapter Manufacturer's Name Pitless Adapter Installer: Franklin Constant Pressure System: 10SDQP 1.5HP 1.5 HP 10 Feet B-10 U/K Well Disinfected Upon Completion? Method of Disinfection: Com ments: Yes Chlorine Pum plnstallerNam e: Arctic Pump & Well, Inc. II~'e&~e~clay, October 27, 2010 Permit Number: Tax Code Number: Work Type: On-Site Water & Wastewater System Permit OSP101027 05032130000 WellSeptic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Initial ] l)epartmen( Permit Effective Dates: May 28, 2010 to May 28, 2011 Design Engineer: STEVE ENG Subdivision: TIMBER RIDGE Site Legal Address: TIMBER RIDGE BLK 2 LT 12 G:0255 Owner/Address: MIKE QUINN CONSTRUCTION 19509 SECOND ST EAGLE RIVER AK 99577 Site Mailing Address: Lot Size in Sq Ft: 31779 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to Apd115, a subsurface soil absorption system under construction dudng freezing weather must either. A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: ~) ~ Date: 0~//~//'O Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, Alaska 99507 www. muni.org/onsite (907) 343-7904 ON-SITE SEWERANELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. (~)~'g) ~.~::~ [-- ~ Proper owne,(s) Mailing address ~0. /~7'7 Site address //~./'~7~'/~ '"~f ~,~ ~ ¢,r-//,~ ~ ~,,'/~'.~ Legal description (Sub'd., Block & Lot) "7-//ldZ~'/~/'z /'~/'~ G'~ Legal description (Township, Range & Section) Lot Size Sq. Ft. Number of Bedrooms Day phone Zip Code Zip Code ._7 THIS APPLICATION IS FOR (~ all that apply): Absorption Field ~ Septic Tank Holding Tank ~ Priw Private Well ~'~ Water Storage THIS APPLICATION IS AN: Initial '~ Upgrade [] Renewal [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized a~ent) PermitJRush Fees: Date of Payment: Receipt Number:. (Rev. 11105) Waiver Fees; Date of Payment: Receipt Number. MEMO Steve Eng, PE, PH P.O. Box 770724, Eagle River AK 99577 (907) 694-7028 tel northrimeng@aol.com Date: 5/13/10 To: MOA On-Site Services Subject: Timber Ridge, Block 2, Lot 12 Septic System Design & Well Siting Number of Pages: 6 A new house and wastewater system are planned for the subject lot. The test hole showed bedrock ~ 10', and no groundwater. The design calls for a new trench, new septic tank & private sewer lines. Private water wells serve the area lots and are shown in drawings. A new water well is also proposed. Please review the wastewater system design for the single family home. I have included design plans & specs, design guidelines, & soil tests. If there is need for additional information or clarification please give me a call. Thanks-Steve ' [, _Nx~?=N E Ei~IN~ Timber Ridge S/D, Block 2, Lot 12 SPECIFICATIONS & DESIGN GUIDEI,INES Wastewater System Sizing: This is a new 3-bedroom, single family home. This is an older subdivision and some of the neighboring lots are developed. Many lots are still undeveloped. These lots are large and are served by private water wells. No adverse impacts are expected from development. No conflicts to the other lots will take place by this septic system and water well construction. The easements are located on the drawing and are not encroached upon. Soil tests revealed sandy gravel soil with Iow silt. An application rate of 1.2 GPD/FT~ with 0.58 reduction factor for utilizing a 5' wide trench. Trench Length = 375 FT~/5'x .58 reduction factor -- 44'; I line ~ 50'. Bedrock was encountered at I 0', no groundwater xvas encountered. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations. · Two compartment, 1000 gallon septic tank. Watertight couplings on inlet & outlet. · 5' minimum between the tank and bed. 1 O' to property lines. · 3' of cover or insulation is required for trench; an equivalent of 1' insulation for each foot soil cover. · Tank & solid pipe must be set on well compacted, stable soil. · 4 inch diameter cleanouts with airtight caps are required I' to 4' from foundation wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10' from the tank positioned to provide cleanout access towards the tank and towards the absorption field. · All cleanouts must extend to at least ground level. · In solid pipe runs, ASTM D-3034 may be used in lieu ofcast iron. · Trench to be placed level, minimum of 4' to groundwater, 6' to bedrock from drain- rock. · Drain rock to be lA inch to 2 IA inch screened. Drain rock to be distributed uniformly throughout the trench. · Perforated pipe to be installed level with perforations down. · Silt barrier (filter fabric) to be installed above the drain rock. · Smeared trench sides must be raked or scarified before drain rock placement. · The finish grade must be mounded to promote drainage over the trench. · Insulation must be placed over any pipe installed under driveways or parking areas. · Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, · Sewer Service Line is minimum 2% slope. · Septic Tank to be pumped every two years or when required. · Insulation board to be extruded direct burial polystyrene (Dow Styrofoam HI/equal) O. o o 0 ~ U > U C L. C 0 U C ~J I::1:1 Lq 0 C 0 0 OL,J 0 c' C U C L. 0 0 0 0 C c~ U U o C). £ 0 C 0 U ..~ 0 U L....~ ~J ~' t.,..I <12 0 SOILS LDG - PERCDLATIDN TEST Dote PerFormed: 8/5/09 PerFormed For~ Mike Quinn Legat Description: Timber Rid,ge Subdivision, Block 8, Lot 18 5- 6 - 7 - 8- 9 - 10 - ll - 12 - 13 - 14 - 15- 16 - 17 - 18 - 19 - 20 - 21 - DEPTH (FEET) Drganic SP Sand w/Gravel w/ Low Silt T.H, Loca'bon. See Attached Groundwater? No ])ep%h -- Wa*cer Depth AF~cer Monitoring. None Date, 5/18/10 Design # Da~e Gross Time Ne% Time Depth Ne~ Drop I 5/18 0 -- 7, -- 2 5/18 10 10 Min, 10.5' 3.5' 3 5/12 12 -- 7, -- 4 5/12 22 I0 Min. 10.5' 3.5' 5 5/18 25 -- 7, -- 6 5/12 35 10 Min. 10.5' 3.5' 7 5/)2 37 -- 7, -- 8 5/12 47 10 min. 10.5' 3.5' 9 5/12 50 -- 7, __ 10 5/12 60 10 Min. 10.5' 3.5' Percolation Rate 3 Min./inch Perc Hole Diameter 6' Test Run :Between 3' and 4' ComMent$~ PrP¢;no~pd. PerFormed By Nori:hRim Fng, I ~ CERTIFY THAT THIS PerForMed in Accordance with Atl. State/Muni¢ipat Guidetines ON THIS DATE. DATE, 5/1P/lO TEST WAS in EFFect TESTHBLE LOG GEBTECHNICAL TIHBER RIDGE B8 T,H, 1 5/25/10 oF 2 SOILS LDG - PERCOLATION TEST Date PerForMed: 5/12/10 PerFormed For: Mike Quinn Legout Description: TiMber Ridge Subdivision, Brock 8, Lot 18 DEPTH (FEET) a- 4 - :.. :,....,.., 8- ':O.'":'".' 9- .'.x'~.'r~.~..,. 10 - 11 - 12 ~ 13 - 14 - 15 - 16 - 17 - 113 - 19- 20- 21 Organic SW Sand w/Graver w/ Low Sitt T,H, Location: See Attached Design Groundwater? No Depth -- W~ter Depth AFter Monitorinc.None Date, 5/18/10 " Dote Gross Time Net TIMe Depth Net Drop ! 5/12 0 -- 7, -- 2 5/12 10 10 Mir. 10.5° 3.5° 3 5/12 12 -- 7. -- 4 15/12 22 10 Min. 10,5' 3.5' 5 5/12 25 -- 7, -- 6 5/18 35 10 min. 10.5' 3.5' 7 5/12 37 -- 7, __ 8 5/12 47 10 Min, 10.5' 3,5' 9 5/12 50 -- 7- __ I0 5/12 60 10 Min. 10.5° 3.5' Percotation Rate 3 Min./inch Perc Hote DiaMeter 6' Test Run Between 3' ond 4' COMMents: Prpqnnkpd, PerFormed B~2~g. I PerFormed ~n Accordance with ON THIS DATE. DATE, 5/12/t0 ~ CERTIFY THAT THIS TEST WAS Att State/Municipat Guidetines in EFFect TESTHOLE LOG GEOTECHNICAL T.H, 8 8970 • • Municipality of AnchorageJi On-Site Water and Wastewater Programn18 (907) 343-7904 >�+�E :4s:)/Y1 s I1, c Certificate of On-Site Systems Approval 0i ��w l 6 8 1, Parcel I.D. 050-321-30 Expiration Date: ^�' 1 1. GENERAL INFORMATION Complete legal description Timber Ridge Block 2 Lot 12 Location (site address) 19220 Timberline Dr. Current Property owner(s) James & Jennifer Everts Day phone Mailing address 19220 Timberline Dr. Eagle River, AK 99577 Real Estate Agent Day phone 2. TYPE OF DWELLING: • Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: ,Received • : Date: (-(2-15i) I COSA to be released to the engineer,unless otherwise equested by the engineer. COSA Fee $ 6-Afa Waiver Fee $ Date of Payment 57a130 Date of Payment Receipt Number d 1g3R Receipt Number COSA# 23 ./glaa41 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,and regulations in effect at the time of installation. In conducting an adequacy test,I attempt to provide a thorough,conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations.The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition,ground water levels that may fluctuate during the year,and the water usage of the family being served by the system.These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system,nor do they guarantee that there are no hidden defects or encroachments.Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system.The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Phone (907) 272-8218 Address P.O. Box 100217, Anchorage Ak. 99510 Engineer's Printed Name Steven R Pannone Date 5/22/2018 4�OF AL, tkkk *: 1HTM Ai 9*g 6. DSD SIGNATURE "" " A"". � System #1 Approved for 3 bedrooms •S even R. 'annone: �fig. CE-8149 System#2 Approved for bedrooms s••• Disapproved �kk �PROFESSI*' � Conditional approval for bedrooms, with the following stipulations: �yOF I\NCyp, CFS \10"j •U OC'RP /On.hgcPr's c�G Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet r If more than 1 septic system is on the lot: COSA Checklist# 1 of 1 Structure served by this system 1 Certificate of On-Site Systems Approval Checklist Legal Description: Timber Ridge Block 2 Lot 12 Parcel ID:050-321-30 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N) Y Date completed 6/4/2010 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Total depth 305 ft. Cased to 49 ft. Casing height(above ground) 24+ in. FROM WELL LOG AT INSPECTION Date of test 6/4/2010 5/10/2018 Static water level 40 ft 56.9 ft Well production 0.8 g.p.m. 3.5 g.p.m. WATER SAMPLE RESULTS: Coliform NEG colonies/100 mL Nitrate 2.10 mg/L Arsenic ND ug/L Date of sample: 5/10/2018 Collected by: PES B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 6/8/2010 Tank size 1000 gal. Number of Compartments 2 Cleanouts(Y/N) Y Foundation cleanout Y/N) Y Depression over tank(Y/N) N High water alarm (Y/N) N/A ----T.I Date of pumping \D/ CC I I PumperS p,( m In1 v C. ABSORPTION FIELD DATA Date installed 6/8/2010 Soil rating (g.p.d./ft2 or ft2/bdrm) 1.2 GPD/SF System type Shallow Trench Length 47 ft. Width 5 ft. Gravel below pipe 3 ft. Total dep 141.0• ft. Eff. absorption area 405 ft2 Monitoring tube Y Depression over field N Date of adequacy test 5/10/2018 Results (Pass/Fail) PASS For 3 bedrooms Fluid depth in absorption field before test 0 in. Water added 450 gal. New depth 0 in. Elapsed Time: 120 min. Final fluid depth 0 in. Absorption rate >= 450+ g.p.d. N Any rejuvenation treatment(past 12 mo.) (Y/N &type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100+ On adjacent lots 100+ Absorption field on lot 100+ On adjacent lots 100+ Public sewer main 75+ Public sewer manhole/cleanout 100+ Sewer/septic service line 25+ Holding tank 100+ Animal containment areas 50+ Manure/animal excrete storage areas 100+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 10+ Property line 5+ Absorption field 5+ Water main 10+ Water service line 10+ Surface water 100+ Wells on adjacent lots 100+ ABSORPTION FIELD ON LOT TO: Property line 10+ Building foundation 10+ Water main 10+ Water Service line 10+ Surface water 100+ Driveway, parking/vehicle storage 10+ Curtain drain 50+ Wells on adjacent lots 100+ F. COMMENTS Survey on file. G. ENGINEER'S CERTIFICATION ,1 . OF 4 111 Iggkp c4ft! I certify that I have determined through field inspections and _Aro.- �4 -..v h review of Municipal records that the above systems are in 0*; TH .4;:‘ •.* conformance with MOA COSA guidelines in effect on this date. %•• ••• `4�I,•• ••••• r Engineer's Printed Name Steven Pannone '911;42:. i ':S1e;reri .'Nonriorie:'•f Date 5/22/2018 91%. •• CE-8149 0i/ COSA canary sheet_2-6-15.doc Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 ~ Anchorage, AK 99519-6650 www. muni.org/onsite , (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A ,SINGLE FAMILY DWELLING Parcel I.D. 050-321-30 COSA # Expiration Date: 1. GENERAL INFORMATION Complete legal description Timber Ridge, ]~Lock 2 Lo~c 12 TimberLine ])rive Location (site address) Current Property owner(s) Quinn Day phone 694-4955 Mailing address PB ]~ox 77P64~. Lending agency Day phone Mailing address Real Estate Agent ])ee Quinn Day phone 229-4966 Mailing Address RE/MAX- Ec~gLe River Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OFBEDROOMS: 3 TYPE OF WATER SUPPLY: Individual Well [] Individual Water Storage [] Community Class __ Well [] Public Water System [] TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding Tank Community On-site Public Sewer [] [] The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my. investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the~-~sit~ water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal an~ ~tate~[~,.des ordinan~e~,~.a.':'hd regulations in effect at the time of installation. ' ~ ~' i.~. i~. iii'~'~ii~ ~:::~?*? Nor-'thRim En~ineer'in_Q ' 694-70F'8 '~:' N~,'~f Firm ~ ~ Phone Address ¥'teve l-n9 10/~7/10 Engineer's Printed Name Date DSD SIGNATURE ~ Approved for Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory X Nitrate Advisory By: (Rev. 11/O5) Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other ~Original Certificate Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL 'CHECKLIST Legal Description: A. WELL DATA Timber- Ridoe: Rlock 2 Loi: 1P Parcel ID:050-3P]-30 Well type P Date completed 6/4/10 Total depth 3 0 5 ft. Date of test Static water level Well production WATER SAMPLE RESULTS: Coliform 0 coloniesil00 mL Arsenic: 0,157 mg/I B. SEPTIC/HOLDING TANK DATA If A, B, or C provide PWSID # __ Sanitary seal (Y/N) Y Cased to4 9 ft. FROM WELL LOG 6/4/10 40 ft. 0,8 g.p.m. <MRL Nitrate 0,10 mg/L Date ofC~'r~ 10 Well Log (Y/N) Y Wires properly protected (Y/N)Y Casing height (above ground) ;:> 4" in. AT INSPECTION na ff. na g.p.m. Other bacteria 0 colonies/100 mL Collected by: NRim En9 Tank Type/Material Anchorage Tank/ Tank size 1000 gal. Number of Compartments Foundation cleanout (Y/N) Y Depression over tank (Y/N~ Date of pumping new Pumper new 6/8/10 Date installed Y Cleanouts (Y/N) High water alarm (Y/I~I ABSORPTION FIELD DATA Date installed 6/8/10 Soil rating (g.p.d./ft2 or ft2/bdrm) 1';:> 47 5 Length ft. Width ft. 6,5 405 Total depth __ ft. Eft. absorption area ~ Monitoring tube na new Date of adequacy test Results (Pass/Fail) trench System type Gravel below pipe3 ft. Y N Depression over field ~ For bedrooms Fluid depth in absorption field before test __ in. Elapsed Time': __ min. Final fluid del~th i Any rejuvenation treatment (past 12 mo.) (YIN & type) Water added gal. New depth in. in. Absorption rate >= g.p.d. If yes, give date D. LIFT STATION Date installed Size in gallons "Pump on" level at ~ in. "Pump off" level at ~ Datum Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL'ON LOT TO: Septic tank/lift station on lot !00' + Absorption field on lot 1 an' + Public sewer main NA Sewer/septic service line 25' t Animal containment areas i00' + in. Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? On adjacent lots 100' + . On adjacent lots 100' + Public sewer manhole/cleanout NA Holding tank NA Manure/animal excrete storage areas Property line 10' + Water service line 10' + Absorption field Surface water 5/ + SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 10' + Water main HA Wells on adjacent Iots~ nn, + SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Building foundation 10'+ Surface water 100' + Wells on adjacent Iotst00' + !00' + Property line 10' + Water Service line 10' + Curtain drain na F. COMMENTS Water main NA Driveway, parking/vehicle storaget0' + in. G. ENGINEER'S CERTIFICATION . . I ce~i~ that I have determ;~d through field inspections and review of Municipal records that the a~ve systems are in conformance with MOA COSA guidelines in effect on this date. Engineer s Pnnted Name S~eve En9 Date 10/27/10 COSAF S W i . FeeS Date of Payment Receipt Number (Rev. 11/05) Date of Payment Receipt Number Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www. cl. anchorage, ak.us (907) 343-7904 Water Well Advisory Certificate of On-Site Systems Approval (COSA) # 101273 During a recent COSA on-site inspection and test of the potable water supply well on Block 2, Lot 12 of Timber Ridge subdivision, the well's productivity was determined to be 0.8 gallons per minute. The minimum well productivity required by this Department (AMC 15.55) for a 3-bedroom residence is 0.31 gallons per minute. Although the subject well currently exceeds this minimum requirement, all parties concerned are advised that the production capacity of the well may fluctuate. Restriction of non-critical water uses such as washing cars and watering lawns and gardens may be required. This advisory must be attached to all copies of the subject Certificate of On- Site Systems Approval. ANALYTICA GROUP Northrim Eng Attn: Steve Eng 17237 Bear Paw Circle Eagle River, AK 99577 907-694-7028 Fax: 907-694-7026 Client Sample ID: Eagle River 5 Sampling Location: 77,,'~ Client Project: Eagle River 5 Sample Matrix: Drinking Water COC #: PWS#: Residual Chlorine: Comments: SP-Analytica, Inc.-Anchorage 4307 Arctic Blvd. Anchorage, AK 99503 Phone: 907-258-2155 Fax: 907-258-6634 Report Date: 10/13/2010 Receipt Date: 9/30/2010 Sample Date: 9/29/2010 Sample Time: 6:00:00PM Collected By: Steve Flag Definitions: MRL = Method Reporting Limit MCL = Maximum Contaminant Limit B = Present also in Method Blank H = Exceeds Regulatory Limit M = Matrix Interference J = Estimated Value D = Lost to Dilution ** = RL higher than MCL; target not detected TNC = Too Numerous to Count - result rejected CF = Confluent Growth - result rejected TCNG = Turbid Culture No Growth - rejected Lab#: A 1009377-01A Analysis Method Prep Prep Analysis Parameter Result Units Flags MRL MCL Method Date Date Analyst 4500-NO3E (Aqueous) - Nitrate+Nitrite pres Test was conducted by: Analytica - Anchorage Nitrate-Nitrite as Nitrogen <MRL mg/L 0.10 10 10/8/2010 10/8/2010 MC Lab#: A1009377-01B Analysis Method Prep Prep Analysis Parameter Result Units Flags MRL MCL Method Date Date Analyst 9223B-PA (Aqueous) - Coliforms in DW E. Coli Pass PASS/FAIL 1.0 Total Coliform Pass PASS/FAIL 1.0 Lab#: A1009377-01C Test was conducted by: Analytica - Anchorage 1 9/30/2010 9/30/2010 KM 1 9/30/2010 9/30/2010 KM Analysis Method Prep Prep Analysis Parameter Result Units Flags MRL MCL Method Date Date Analyst 200.8/200.8 (Aqueous) - Family Well Water I Arsenic 0.157 ug/L 0.15 Test was conducted by: Analytica - Thornton 10 200.8 10/7/2010 10/7/2010 RM Page 3 of 3 / / / / I Lot 1 2 51,779 s.f. 1.5' x 8.2' 129.3'  SEPTIC N L°t ROLLING HILLS COV[REO-~ PORCH 212.81 I VIEW x 5.2' CANT BALCOfiY ESTATES PLOT PLAN AS BUILT ~ SCALE 1' = 40' GRID NW 255 Project No. 10-075 Long (907) 522-6476 Registered Land Surveyors (907) 522-4625 kgtangleOalaska.net / JclangleOalaeka.nef Associates, inc. ~500 Daryl Avenue, Anchorage, Alaska 99515-;5049 Phone Fax I hereby certify that I have surveyed the following de~cribed properly: Lot 12, Block 2, TIMBER RIDGE SUBD. (Plat No. 70-219) Anchorage Recording District, Alaska, and that the improvemen~ Mfuated thereon are within the property lines and do not encroach onto the property adJooent thereto, that no Improvements on the property lying adJa=enf thereto enoroach on the surveyed premises and that there are no roadways, transmission lines or other vlslble easements on said properly except as indloatecl hereon. Dated this the ~-~-~ Day of ~-r-oC~zC~-- , 7.~.~ , at Anahorage, Alaska It Is the responelblllty of the owner to detsrznlne the existence of any easement~, covenants, or re.frictions which do not appear on the reaorded subdivision plat.