Loading...
HomeMy WebLinkAboutT15N R1W SEC 19 LT 23T15N R1W Sec.19 Lot 23 #051-241-02 RIN ®,.. Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904` . ON-SITE WASTEWATER INSPECTION REPORT 4 0 Permit Number: OSP201021 PID Number: 051-241-02 �0 Dwelling: 0 Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New 0 Upgrade Name LINDA EVANS PTION FIELD Pr_1 Trench ❑Wide Trench ❑Bed ound OtherPhoneof Site Address 18920 SPRUCE CREST DRIVE, EAGLE RIVER, AK 99577 360-6691 Bedrooms 3 /SF Total depth f original grade Ft. LEGAL DESCRIPTION Depth to pipe invert from orig EXISTING depth beneath pipe Ft. Subdivision Block Lot - - 23 Fill added above original gr IGnh Ft. Ft. Township Range Section 15N 1 W 19 Gravel width Ft. Beds: Number of Lines Dista between lines Ft. SEPARATION DISTANCES To From Septic Tank Absorption Field Lift Station Holding Tank Sewer Line Total orption area Ft2 Number of trenches Dist. between t ches Well *78' EXISTING _ _ 25'+ TANK ❑e Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer GREEK TANK Capacity 1000 Gal. Surface Water 100'+ EXISTING _ _ Material Number of compartments Lot Line rj'+ EXISTING _ _ NA HDPE PLASTIC 2 Foundation 10'+ EXISTING _ _ L kTION Manufacturer Capacity Remarks *PHYSICALLY MEASURED. 75' WELL WAIVER Gal. GRANTED (WAIVER # OSV201007) Alarm location Electric fled by Installer RED DOG MASONARY PIPE MATERIAL House to tank ABS F628 Tank to ABS F628 (FOR NEW) dralnfleld (FOR NEW) Drainfield EXISTING CO/MT ABS F628 Inspector JODY MAUS, GEG CONSULTANT BENCH MARK (Assumed elevation) 100.00 ft Inspdectio v, 6/23/2020 Zia - 3"' - 4th _ Location and description BOTTOM OF SIDING @ NE CORNER OF HOUSE ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional Approval: Date 060 4_7 �o�. y�J *C'). • 4. T, �*�Q f/'...... .. .A . . ...... �--✓ J.. . r ....� O f ,A r .: �r y Ga SS. �p dp9 f IJ c -7p53 Op 1f � Pre �}'. #AECC884 OO�OppO� Septic System ApprovedY211t&M Date g t da�� Note: this approval does not include well permit requirements.p,°fes5°�°oma PERMIT NUMBER: PARCEL ID NUMBER: OSP201021 RECORD DRAWING 051-241-02 NOTE: OLD SEPTIC TANK WAS COMPLETELY REMOVED AND DISPOSED OFFSITE PER CONTRACTOR 0 0) z 0 P w z F- — — — — — — — — — — — — — SPRUCE CREST DRIVE NEW 1,000 GALLON HOPE GREER TANK INSTALLED DOUBLE CLEANOUTS (DBL3 & D EXISTING LOG CRIB. PASSED SEPTIC ADEQUACY TEST ON 12/26/2019. CONTRACTOR EXTENDED MONITORING TUBE 12" ABOVE GRADE -7 -IT OF WAY FOR ND PUBLIC UTILITIES INSTALLED DOUBLE MT CLEANOUTS (DBL1 & DBI -2) A 7 EXISTING 3 BED OM O'A HOUSE 0 41 EXISTING WELL 100' WELL RADIUS I A I B C DBLI 37.8 1 7.4 33.4 DBL2 39.3 1 9.3 35.4 MH -97 -1 45.6 1 17.3 42.9 49.2 1 21.6 47.1 6-55 -5-2-2-T 2-5.3 50.6 E-BL254�.327.4 ENGINEERING SALES, CONSULTING -, 10 525 VT- 71.7 1 44.0 67!5 N SCALE: ...... ........ # GARNEIS'" EN(ff Erd k�i -ANT-1 RIN' '-N R olr Tp Ltd Vi u Ltd 0 ..... 9 . .... .. ......... ........... ENGINEERING SALES, CONSULTING -, 10 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507 - PHONE (907) 337-6179 - FAX (907) 338-3246 • WEBSITE: www-gamessenginee6ng.00M ............ • .............. j4L PREPARED FOR: LINDA EVANS.: PHONE NUMBER: 907-360-6691 PAGE NUMBER: 20F3 mess 0 E- 5 !;� Alr AV 4w 0 ... .... 41p I PROJECT/LEGAL DESCRIPTION:DRAWN Tl 5N Rl W SECTION 19 LOT 23 BY: J.L.M. TYPE OF WORK: DATE: RD DRAWING OF SEPTIC TANK UPGRADE O� �,_� 7/6/2020 NSE LICE IL #AE C884 PERMIT NUMBER: PARCEL ID NUMBER: OSP201021 RECORD DRAWING 051-241-02 FINAL GRADE TOP OF MH LID = 98.98 = 98.83-98.90 MH TOP TANK I I TOP OF OUTLET =94.71 INLETT = 94.73- @ INVERT OF BUNG @ INLET = 94.08 —/ NEW 1000 GALLON INVERT OF BUNG GREER HDPE @ OUTLET = 93.91 SEPTIC TANK OF �_._cP.•• GAR ESS ENGINEERING G ROUP, Ltd 4 ••••... � ..••• ENGINEERING SALES CONSULTING .....••/ •••0 3701 E. TUDOR ROAD, SUITE 101 ' ANCHORAGE, AK 99507' PHONE (907) 337-6179 • FAX (907) 338-3246WEBSITE: www.gamessengineedng.00m ,� ... .......... ........�.,y.,,; PREPARED FOR: PHONE NUMBER: PAGE NUMBER: C� :, A. Gar SS LINDA EVANS 907-360-6691 3 OF 3 Cl;- 53 ' ?� PROJECTlLEGAI DESCRIPTION: DRAWN BY: Tl 5N R1 W SECTION 19 LOT 23 J.L.M. Fp••'••• ....... ,�,�,,\\ TYPE OF WORK: DATE: �,_ RECORD DRAWING OF SEPTIC TANK UPGRADE 7/6/2020 # LICENSE r',p 4%��is��'� . � Lot 205-A | Lot 205-8 | ___ _____________________ . . __ _ ___ ' | ___._______ EDGE or ROAD SPRUCE CREST DRIVE ��,,a6' CONC. PORCH / \_ WITH FUEL TANK BELOW� \ | nr 5.9' SHED IL / \ ~~ 12' " `z HORSE STALL Lot 23 1o8,y00a� | w oynnno'n 32945' | Lot 25 L� �� 60 | PLOT PLAN AS BUILT SCAL(IlL-=� �5CV GRID NW 9.54 proje 11500 Daryl Avenue. Anchorc Lang OR Associafes, inc. (907) 522-6476 Phone (907) 522-4625 Fox Professional Land Surveyors ken0longsurvey.com I hereby cariffy that I have surveyed the following described property: Lot 23, SECTION 19, T15N. R1W. SEWARD MERIDIAN, ALASKA Anchorage Recording District, Alaska, and that the Improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that no Improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission lines or other visible easements on sold property except as Indicated hereon. Dated this the __���_ oq, of . ����_. at Anchorage, mnsxm it Ism* responsibility of the owner :, determine the existence of any ments. on,enomm, or restrictions which do not appear on the recorded subdivision plot. W | Lot 27D ' sEPncnpES-»- / ROADWAY AND PUBLIC UTILITES / , STORY z / ess/mENcc ' 9.+' , 12.1' GREENHOUSE WITH DAYLIGHT \ ` BASEMENT / m',3.3'-/ + | CANT \ \ \ ` ^ \` / \_ WITH FUEL TANK BELOW� \ | nr 5.9' SHED IL / \ ~~ 12' " `z HORSE STALL Lot 23 1o8,y00a� | w oynnno'n 32945' | Lot 25 L� �� 60 | PLOT PLAN AS BUILT SCAL(IlL-=� �5CV GRID NW 9.54 proje 11500 Daryl Avenue. Anchorc Lang OR Associafes, inc. (907) 522-6476 Phone (907) 522-4625 Fox Professional Land Surveyors ken0longsurvey.com I hereby cariffy that I have surveyed the following described property: Lot 23, SECTION 19, T15N. R1W. SEWARD MERIDIAN, ALASKA Anchorage Recording District, Alaska, and that the Improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that no Improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission lines or other visible easements on sold property except as Indicated hereon. Dated this the __���_ oq, of . ����_. at Anchorage, mnsxm it Ism* responsibility of the owner :, determine the existence of any ments. on,enomm, or restrictions which do not appear on the recorded subdivision plot. W | Lot 27D 33' RIGHT-OF-WAY FOR ROADWAY AND PUBLIC UTILITES ' 9.+' , 12.1' GREENHOUSE \ ` / \_ WITH FUEL TANK BELOW� \ | nr 5.9' SHED IL / \ ~~ 12' " `z HORSE STALL Lot 23 1o8,y00a� | w oynnno'n 32945' | Lot 25 L� �� 60 | PLOT PLAN AS BUILT SCAL(IlL-=� �5CV GRID NW 9.54 proje 11500 Daryl Avenue. Anchorc Lang OR Associafes, inc. (907) 522-6476 Phone (907) 522-4625 Fox Professional Land Surveyors ken0longsurvey.com I hereby cariffy that I have surveyed the following described property: Lot 23, SECTION 19, T15N. R1W. SEWARD MERIDIAN, ALASKA Anchorage Recording District, Alaska, and that the Improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that no Improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission lines or other visible easements on sold property except as Indicated hereon. Dated this the __���_ oq, of . ����_. at Anchorage, mnsxm it Ism* responsibility of the owner :, determine the existence of any ments. on,enomm, or restrictions which do not appear on the recorded subdivision plot. W | Lot 27D 12' " `z HORSE STALL Lot 23 1o8,y00a� | w oynnno'n 32945' | Lot 25 L� �� 60 | PLOT PLAN AS BUILT SCAL(IlL-=� �5CV GRID NW 9.54 proje 11500 Daryl Avenue. Anchorc Lang OR Associafes, inc. (907) 522-6476 Phone (907) 522-4625 Fox Professional Land Surveyors ken0longsurvey.com I hereby cariffy that I have surveyed the following described property: Lot 23, SECTION 19, T15N. R1W. SEWARD MERIDIAN, ALASKA Anchorage Recording District, Alaska, and that the Improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that no Improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission lines or other visible easements on sold property except as Indicated hereon. Dated this the __���_ oq, of . ����_. at Anchorage, mnsxm it Ism* responsibility of the owner :, determine the existence of any ments. on,enomm, or restrictions which do not appear on the recorded subdivision plot. W | Lot 27D MUNICIPALITY OF ANCHORAGE „C„r On -Site Water & Wastewater Program �o� Is, PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite v Department On -Site Wastewater Disposal System Permit Permit Number: OSP201021 Effective Date: 2/14/2020 Work Type: SepticTank Upgrade Expiration Date: 2/13/2021 Tax Code Number: 05124102000 Site Legal Address: T15N R1 W SEC 19 LT 23 G:0954 Site Mailing Address: 18920 SPRUCE CREST DR, Chugiak Owner: EVANS LINDA Lot Size in Sq Ft: 108900 Design Engineer: GARNESS ENGINEERING GROUP LTD Total Bedrooms: 3 This permit is for the construction of: ❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or tovered, sealed, and heated to prevent freezing ial Provisions: Contractor shall locate new septic tank as far from the well as possible, but maintain um 5 ft separation to existing drainfield. Received B� Issued By: Date: r Date: ' liltTl(_ s -Municipa' ity: ®f Anchorage _ c .N Depart Wilt P.O. Box 196650 ® 4700 Elmore Road Anchorage, Alaska 99519-6650 O (907) 343-7904 m Fax (907) 343-7997 hftp://www.muni.org/Onsite Development'Services Department On -Site Water and Wastewater Section * * * * 'VARIANCE/WAIVER REVIEW * x * * Waiver#: OSV201007 COSA#: Permit#:OSP201021 PID#: 051-241-02 Legal Description: T15N R1W Section 19 Lot 23 Engineer: Garness Engineering Group Applicant: Linda Evans Your request for a waiver of the required 100 feet horizontal separation from the septic tank to the private well has been approved. The approved separation distance is 75.0 feet. See engineer's waiver request for justifications. This waiver approval applies to the proposed septic tank only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ......................................................................... 9 N 0 N R i Waiver is Granted: X Waiver is not Granted: Date: LIZ11, _ZXa� Approved by: 7Q, l Name of Reviewer ■ ■ ... t .. ■ ■ ■ ■ ■ ■ 1 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 9 x K ■ ■ ■ ■ ■ . ■ t t ■ ■ ■ ■ .. ■ ■ ■ ■ ■ ■ ■ . t ■ ■ ■ ■ ■ 1 t ■ ■ ■ ■ ■ ■ t ■ ■ ■ 1 t ■ ■ t **** VARIAN C E/WAIVER REVIEW **** MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Fax: 907- 343-7997 On -Site Water & Wastewater Program Mayor Dan Sullivan On -Site Sewer[Well Permit Application For A Single Family Dwelling Parcel I.D. 051-241-02 Property owner(s) LINDA EVANR5 Day phone 907-360-6691 Mailing address 18920 SPRUCE CREST DRIVE *CHUGIAK, AK 99567 Site address 18920 SPRUCE CREST DRIVE *CHUGIAK, AK 99567 Legal description (Sub'd, Block & Lot ) LOT 23 Legal description (Township, Section & Range) T15N, R1 W, SECTION 19 Lot Size APPLICATION IS FOR: IN all that apply) Absorption Field ❑ Septic Tank Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Sq.Ft. Number of Bedrooms 3 APPLICATION IS AN: Initial ❑ Upgrade Renewal ❑ THIS APPLICATION INCLUDES A VARIANCE/ WAIVER REQUEST FOR: WELL TO SEPTIC TANK TYPE OF DEWELLING: Single Family (SF) (w/wo ADU) Duplex (D) ❑ Multiple Dwellings ❑ (SF and/or D) Distance: 75 FEET I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) Permit/Rush Fees: aas Waiver Fees: it 1:36 Date of Payment: V11,319oa6 Date of Payment: Receipt Number: ()(g6;Zg6 Receipt Number: Permit No. (15P loaf Waiver No. V (Rev. 01111) GARNESS ENGINEERING GROUP, Ltd - ENGINEERING SALES CONSULTING - - January 8, 2020 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Ref: Proposed Septic Tank Upgrade for T15N, R1 W, Section 19, Lot 23 To whom it may concern: The subject lot is served by a private well and septic system. Per MOA records, the existing steel septic tank is approximately 46 years old. Per MOA memorandum, a steel septic tank of this age must be physically inspected and/or replaced prior to COSA approval. Based upon this fact, we are proposing to replace the septic tank. We are proposing that the old septic tank be decommissioned per UPC and a new 1000 -gallon HDPE Greer tank (rated for 10' burial) be installed. See attached design drawings for the tank location and other MOA requirements. As can be seen on the attached design drawing, we are requesting a 75 -foot waiver from the well to the new septic tank. The old septic tank was installed in 1973 when the separation distance was only 50 feet. The old septic tank is approximately 68 feet from the well. We have recently pulled water samples for Total Coliform Bacteria, Nitrate and Arsenic from the well. Attached are the lab results and based upon these results, it appears there has been no adverse effects on the well with the existing encroachment. The well head is also at a higher elevation than the grade at the septic tank. In short, there appears to be minimal risk with the granting of this waiver. We would like to note that the MOA Public Inquiry Property Detail website, the house is listed as a 4 -bedroom residence. However, based upon the 2010 appraisal the house is a 2 -bedroom residence (see attached). The original septic system was installed for a 3 -bedroom residence. Per the owner, they are requesting the new septic tank be sized for a 3 -bedroom residence. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. A rely, Pres , P.E., M.S. 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com T15N, R1 W, SECT 19, LOT 24 Qoo CSETicO AR� T15N, R1 W, SECT. 19, LOT 25 NO ENCROACHMENT CONCERNS T15N, R1W, SECT. 18, ,,, LOT 205-A I I I I I I I I I I I I I --------------- I I I i EPTIC AR�D I ------------�-+-�-p--------------�+1T--�-p �VE ,C --------i?r-'r�CV V- -Q7"[ - T- -B R VE ------- PROPOSED NEW - - SEPTIC TANKS - - ' - - — - ��`•^ - - — T15N, R1 W, SECT. 18, LOT 206 NO ENCROACHMENT CONCERNS EXISTING SEPTIC 1 EXISTING , 3 BEDROOM ! HOUSE ARNOLDS; LOT 26A VACANT PER MOA RECORDS GARNESS ENGINEERING GROUP, Ltd ENGINEERING o SALES o CONSULTING - 3701 E. TUDOR ROAD, SUITE 101 -ANCHORAGE, AK 99507' PH(*E (907) 337-6179' FAX (907) 338-3246 • WEBSITE: www.gamessengineedng.com PREPARED FOR:ONE NUMBER: PAGE NUMBER: LINDA EVAN T H907-360-6691 1 OF 2 PROJECT/LEGAL DESCRIPTION: DRAWN BY: T15N R1 W SECTION 19 LOT 23 D.J.G.M.L.M. TYPE OF WORK. DATE: �, SITE PLAN FOR SEPTIC TANK UPGRADE 12/27/2019 T15N, R1 W, SECT. 19, LOT 22 NO ENCROACHMENT CONCERNS W O N SCALE: 1"=100' ARNOLDS; LOT 27D NO ENCROACHMENT CONCERNS F-1 All,,�P••••. ..•,•• •• ♦♦ AV ........ ...... ..... ...0 0 ♦�g' .•Gar ess".• 41 i �'. '"2 CE -79 3 .�••� Ar AV LICENSE #AECC884 \\\\\� j GEG, Ltd. HAS AN 8 PAGE SPECIFICATION LETTER THAT PERTAINS TO THIS DESIGN. BY PROCEEDING FORWARD WITH THIS INSTALLATION, THE ENGINEER, WELL DRILLER, CONTRACTOR AND PROPERTY OWNER AGREE THAT THEY HAVE READ THESE SPECIFICATIONS AND AGREE TO ACCEPT THE TERMS AND CONDITIONS OUTLINED. ----------------- SPRUCE ---------------- SPRUCE CREST DRIVE PROPOSED 1,0000 GALLON HDPE GREER TANK RATED FOR 10' BURIAL; INSTALL DOUBLE EFORE AND AFTER TANK EXISTING LOG CRIB. PASSED SEPTIC ADEQUACY — TEST ON 12/26/2019. CONTRACTOR TO EXTEND MONITORING TUBE 12" ABOVE GRAD _ EXISTING SEPTIC TANK (COLLAPSING). TO BE DECOMMISSIONED PER UI C * •' ; 33' RIGHT OF WAY FOR \ ,'%.d INSTALL NEW _ •'•• �' FOUNDATION CLEANOUT \ N \ I I () IJ I z O F- 0 U Iw � I z H / s ----------------- SPRUCE ---------------- SPRUCE CREST DRIVE PROPOSED 1,0000 GALLON HDPE GREER TANK RATED FOR 10' BURIAL; INSTALL DOUBLE EFORE AND AFTER TANK EXISTING LOG CRIB. PASSED SEPTIC ADEQUACY — TEST ON 12/26/2019. CONTRACTOR TO EXTEND MONITORING TUBE 12" ABOVE GRAD _ EXISTING SEPTIC TANK (COLLAPSING). TO BE DECOMMISSIONED PER UI C I \ \ \ u / / I I \ NOTE: THE CONTRACTOR SHALL HAVE THE 75 FOOT WELL RADIUS FLAGGED/STAKED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION. GARNESS ENGINEERING GROUP, Ltd -- _� ENGINEERING o SALES - CONSULTING -- --_ 3701 E. TUDOR ROAD, SUITE 101 ' ANCHORAGE, AK 99507' PHONE (907) 337-6179' FAX (907) 338-3246' WEBSITE: www.gamessongineering.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: LINDA EVANS 907-360-6691 2 OF 2 PROJECT/LEGAL DESCRIPTION: DRAWN BY: Tl 5N R1 W SECTION 19 LOT 23 D.J.G.M.L.M. TYPE OF WORK: DATE: �, DESIGN OF SEPTIC TANK UPGRADE 12/27/2019 %IS! OF •q ey..�..Gar. ess.:'� �1���• C -79 ZO LICENSE 41S1;`,lkk ����`..•o #AECC884 * •' ; 33' RIGHT OF WAY FOR ROADWAY AND PUBLIC UTILITIES ,'%.d INSTALL NEW _ •'•• �' FOUNDATION CLEANOUT \ NG WELL \ I I I \ \ \ u / / I I \ NOTE: THE CONTRACTOR SHALL HAVE THE 75 FOOT WELL RADIUS FLAGGED/STAKED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION. GARNESS ENGINEERING GROUP, Ltd -- _� ENGINEERING o SALES - CONSULTING -- --_ 3701 E. TUDOR ROAD, SUITE 101 ' ANCHORAGE, AK 99507' PHONE (907) 337-6179' FAX (907) 338-3246' WEBSITE: www.gamessongineering.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: LINDA EVANS 907-360-6691 2 OF 2 PROJECT/LEGAL DESCRIPTION: DRAWN BY: Tl 5N R1 W SECTION 19 LOT 23 D.J.G.M.L.M. TYPE OF WORK: DATE: �, DESIGN OF SEPTIC TANK UPGRADE 12/27/2019 %IS! OF •q ey..�..Gar. ess.:'� �1���• C -79 ZO LICENSE 41S1;`,lkk ����`..•o #AECC884 SGS Ref.# Printed Datetrime 01/08/2020 9:16 Collected Date/Time 12/27/2019 7:46 Received Date/Time 12/27/2019 8:44 Technical Director Stephen C. Ede 1197497001 Client Name Garness Engineering Group, Ltd (GEG) Project Name/# T15N,R1 W,Sec 19,Lot 23 Client Sample ID T15N,R1 W,Sec 19,Lot 23 Matrix Drinking Water Sample Remarks: Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date Init Metals by ICP/MS Arsenic Waters Department Total. Nitrate/Nitrite-N 12.0 * 5.00 ND 0.200 ug/L EP200.8 B (<10) 01/03/20 01/06/20 BMZ mg/L SM21 450ONO3-F C (<10) 01/03/20 EWW SGS Ref.# 1200029001 Client Name Garrtess Engineering Group, Ltd (GEG) ProjectName/lt T15W,R1W,SECl9,LOT23 Client Sample ID T15W,R1 W,SECI9,LOT23 Matrix Drinking Water Sample Remarks: Printed Date/Time Collected Date/Time Received Date/Time Technical Director 01/08/2020 16:00 01/03/2020 7:18 01/03/2020 10:56 Stephen C. Ede Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Lits Date Date Init Microbiology Laboratory E. Coli Negative I 100mL SM21 9223B A 01/03/20 VAB Total Coliform Negative I IOOmL SM21 9223B A 01/03/20 VAB <0 v a 0 > e r — u ® ten s r �w C_ 333o acc® i t w 00 CD CDS S m 0 mit O' rt 00 icr _-i O a O S O �3ZO o�smo"co t u®, vm®mom S m i < U -, 0, ® < m Q ® O V r- V/ Sp " swcaop-D�c Q p.a 0 O ®O a ® CL — p"C ^o a Q 0 0 Q y IE w _ 0 a Do– Q. m T �m!y aI piOD® ( ] Ij p•" ..0.. O � - '^ 03 eam=r < 3 aZao mE CD -+ ( �ir 3=OwotO Q ®® O s mF 3 Z w i s D a o w�" n C) I' � x " a>I , O GO s��m`�� a i � T� u � 0 ®jLn 00. o o ®0 ®vv t ® S' O CT aO p — 0. a p m a p C a tp N N <� �Smnoo O�Ntaa p p a (A ® 0- (0 0 0) �► D am -1 ®0S� snU�iOvim ! 3 0 w O m '4 C f0 `< .mr O "C -q T ® 0 0 a O 0 S. O s° 3 ® n 0 O i p � s r 0 ( vz IOl iLn_ ,6b'8Z£ M Q£,Z 1.00 N m / m CD l D pm p I z�nl� r I j �DOa . 'a m: 1 00 > Ln 00 Q PA Co I� O0 D PA OV5 :I� (J� W p sG'• ''Gj�O d \ r 0 ( vz IOl iLn_ ,6b'8Z£ M Q£,Z 1.00 N m / m CD l D pm p I z�nl� r I j ® Z 1 00 > Ln 00 W N to '146 - c m" \ r- P, D � 2 \ � 7c O \\ J m O x x =- Ln co O ® n to 0 o � to ,tb6'SZ£ 3„00,61.00 S zz }®1 i r*3 0 m m 11 0 M 0 0 Ln 0 C :n o co m\ J O_ N Q Ln i Municipality ®f AnchorageO On -Site Water and Wastewater Program 44 (907) 343-7904 Certificate of On -Site Systems Approval Parcel I.D. 051-241-02 Expiration Date: Oa D 1. GENERAL INFORMATION: Complete legal description T15N, R1 W, SECTION 19: LOT 23 Location (site address) 18920 SPRUCE CREST DRIVE, CHUGIAK, AK 99567 Current Property owner(s) LINDA EVANS Day phone 907-360-6691 Mailing address 18920 SPRUCE CREST DRIVE, CHUGIAK, AK 99567 Real Estate Agent NICHOLE PERRY W/ KELLER WILLIAMS Day phone 865-6557 2. TYPE OF DWELLING: Z Single Family (w/wo ADU) ❑ Duplex 1771 Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual N Individual Water Storage ❑ Holding Tank 1771 Community Class Well 0 Community E71 Public Water System E71 Public Sewer 0 WaiverNariance request for: Distance: Received by: COSA to be released to the engineer, unless otherwise requested by the engineer, COSA Fee $ Date of Payment oZ a C)a C) Receipt Number 015(06 COSA # 0 S C- 20 1 OV -7 Date: Waiver Fee $ Date of Payment Receipt Number, Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date:�fT?� In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system o O�r At in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the system/s on the date/s of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or /. encroachments may exist that were not identified during the evaluation. The operational life of all wells '•7� and septic systems depend upon a variety of variables, including but not limited to, soil conditions, • • • • ;• . . • • • • • • • • • . • • . groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and . . ....... ....... are outside the control of GEG. Satisfactory test results do not guarantee future performance of the �/1 eftr Gorness•r system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of Vn CE 953 ` the well or septic system. GEG makes no representation whether an alternative well or septic system !� can be installed on the property in the event either of the current systems fail to perform adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG to a p�ofessto� o perform the evaluation. Reliance upon the information provided in this report by any other person or party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. #AECC884 6. DSD SIGNATURE J System #1 Approved for 3 bedrooms System #2 Approved for bedrooms Disapproved Conditional approval for bedrooms, OF .I�F.V Ov _S�TE +; sR ��� with the followir> sfipul)ii%;!ATER O 9ROGF.AM 7))j) ))) W)"i))�, By: Original Certificate Date:1 ' v' D The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist_ Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet_10-10-12.doc COSA Checklist Legal Description: T15N, R1W, SECTION 19; LOT 23 If more than 1 septic system on lot: COSA Checklist # 1 of 1 A. WELL DATA FE -1 Well log is filed with Onsite (or attached) Date drilled 7120/73 Total depth 111 ft Cased to 81 ft R Sanitary seal is functioning correctly R Wires are properly protected Casing height (above ground) 12+ in. Date of flow test for COSA 2/19/20 Static water level at beginning of test *44.0 ft. Comments *ON 12/26/2019 B. TANK DATA Age of tank(S) NEW years Tank type/material HDPE Measured operating fluid level in septic tank NEW 11011 Standpipes/foundation cleanout per record drawing Date of pumping NEW D. ABSORPTION FIELD DATA SEEPAGE PIT Which system tested (date installed) 7/73 140 ALL standpipes present per record drawing Total measured depth from grade 8.9 ft (max) Measured depth to pipe invert from grade 4.3 ft (min) ❑ N/A — pressurized field Monitor tubes go to bottom of effective. If not, state depth into effective Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced N/A gallons Comments/Deficiencies: COSA Checklist yellow sheet Parcel ID: 051-241-00 Structure served by this system 1 Well production at time of test 2 1 gpm Water storage tank volume 400 gallons Well disinfected for coliform test? ❑ Yes No ❑■ Coliform bacteria is Negative Nitrate mg/L 0 Nitrate less than MRL (ND) Arsenic 12.0 ug/L ❑ Arsenic less than MRL (ND) Collected by GEG, LTD. Date of Sample 12/27/19 & 1/3/20 STATION ❑ Require6� Age of lift station Lift station material Comments✓ co Adequacy test date 12126119 Results Q✓ Pass For 3 bedrooms Fluid depth prior to test 6 in Water added 536 gal New depth 7 in Elapsed time 120 min Final fluid depth 4 in Absorption rate 450+ gpd Any rejuvenation treatment (past 12 months) " UNK If yes, enter date N/A E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100'Community S Yes *75+ Sewer Manhole/Cleanout > 100' rJ Yes if No ft (Q Yes if No ft Neighboring Tank > 100' R Yes if No ft Private Sewer/Septic Line > 25' Yes if No ft Absorption Field on Lot > 100' ❑ Yes if No **95 ft Holding Tank > 100' Yes if No ft Neighboring Absorption Fields > 100' if No ft Animal Containment > 50' Yes if No ft F/1 Yes if No ft ft If septic tank is under driveway comment below Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' 21 Yes if No ft P1 Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' S Yes if No ft Surface Water > 100' Yes if No ft Property Line > 5' R Yes if No ft Wells on Adjacent Lots: Wells on Adjacent Lots: Absorption Field > 5' Q Yes if No ft Private Wells > 100' Yes if No ft Water Main > 10' Yes if No ft Community Wells > 200' 0 Yes if No ft Water Service Line > 10' Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Q44 . Yes if No ft If absorption field is under driveway comment below Property Line > 10' Q Yes if No ft Wells on Adjacent Lots: Water Main > 10' Q Yes if No ft Private Wells > 100' Yes if No ft Water Service Line > 10' Yes if No ft Community Wells > 200' El Yes if No ft Surface Water > 100' Q Yes if No ft F. ENGINEER'S COMMENTS *WAIVER GRANTED (OSV201007) **WAIVER GRANTED (SEE WR #101051). G. ENGINEER'S CERTIFICATION / certify that / have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet VO y Gar........ss.:... Q44 . CE 79 3 �� #AECC884 0 io�°o rofess��DOO000� MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT / 907-343-7904 On -Site water and wastewater Section Fax: 343-7997 www.muni.org/onsite Arsenic Advisory Certificate of On -Site Systems Approval # OSC201067 Subdivision: T15N R1W Sec.19 Lot 23 A water sample revealed an arsenic concentration of 12 micrograms per liter (ug/L). The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Information on arsenic is available from the On -Site Water and Wastewater Program website (www.muni.org/onsite) or at 343-7904. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. �lail�ng Ac�dress� P O Box 196650* Anchorage Alaska 99519 6650 * www�mum org � �� x Municipality of Anchorage � On-Site Water. and Wastewater Program (907) 343-7904 S X C T YN LE Certificate of On-Site Systems Approval LZ Parcel I.D. 051-241-02 1. GENERAL INFORMATION: Complete legal description T15N, R1W, SECTION 19; LOT 23 Expiration Date: Location (site address) 18920 SPRUCE CREST DRIVE, CHUGIAK, AK 99567 Current Property owner(s) LINDA EVANS Day phone 907-360-6691 Mailing address 18 920 SPRUCE CREST DRIVE, CHUGIAK, AK 99567 Real Estate Agent NICHOLE PERRY W/ KELLER WILLIAMS Day phone 865-6557 2. TYPE OF DWELLING: Z Single Family (w/wo ADU) Fj Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: .3 4. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage ❑ Community Class Well E] Public Water System 0 TYPE OF WASTEWATER DISPOSAL: Individual Holding.Tank ❑ Community ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ No Waiver Fee $ Date of Payment 90 qC) Date* of Payment Receipt Number 0 ol, Q �� (o b Receipt Number COSA # Q 5 C 96 tbuWaiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date: 2lZf�Z� In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system o�OF in accordance with the guidelines and regulations established by the Municipality of Anchorage and ��,.• "' / 4 industry practices. The reported results describe the condition of the system/s on the date/s of the O P,• `9500 evaluation. Separation distances were measured to readily identifiable features. Hidden defects or encroachments may exist that were not identified during the evaluation. The operational life of all wells ° 49— and 9 and septic systems depend upon a variety of variables, including but not limited to, soil conditions, • ' ' • ' • ' • • . • • • • • • • • • • . • . . groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and .... are outside the control of GEG. Satisfactory test results do not guarantee future performance of the Q eff G rness: system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of 009 CE -7953 the well or septic system. GEG makes no representation whether an alternative well or septic system s c G can be installed on the property in the event either of the current systems fail to perform adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG to dprofessionoo� perform the evaluation. Reliance upon the information provided in this report by any other person or ��OOD0000 party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever.�c,1PALIr)' jtp884 6. DSD SIGNATURE System #1 Approved for bedrooms,, '� v System #2 Approved for bedroomsnz ^` Disapproved1 Conditional approval for bedrooms, with the following ,40t�t wl- S Otil g L, By: Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: AO COSA Checklist _ Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet_10.10-12.doc COSA Checklist Legal Description: TI 5N, R1 W, SECTION 19; LOT 23 If more than 1 septic system on lot: COSA Checklist # 1 of 1 A. WELL DATA 0 Well log is filed with Onsite (or attached) Date drilled 7120/73 Total depth 111 ft Cased to 81 ft ❑■ Sanitary seal is functioning correctly 0 Wires are properly protected Casing height (above ground) 12+- in. Date of flow test for COSA 2/19/20 Static water level at beginning of test *44.0 ft Comments *ON 12/26/2019 B. TANK DATA Age of tank(s) 47 years Tank type/material SEPTIC/STEEL Measured operating fluid level in septic tank 0 Standpipes/foundation cleanout per record drawing Date of pumping 'TANK TO BE REPLACE IN SPRING OF 2020 D. ABSORPTION FIELD DATA SEEPAGE PIT Which system tested (date installed) 7/73 0 ALL standpipes present per record drawing Total measured depth from grade 8.9 ft (max) Measured depth to pipe invert from grade 4.3 ft (min) ❑ N/A — pressurized field Q Monitor tubes go to bottom of effective. If not, state depth into effective ❑■ Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced N/A gallons Comments/Deficiencies: 'SEE HOMEOWNER QUESTIONAIRE COSA Checklist yellow sheet Parcel ID: 051-241-00 Structure served by this system 1 Well production at time of test 2.1 gpm Water storage tank volume 400 gallons Well disinfected for coliform test? ❑ Yes IN No 9 Coliform bacteria is Negative Nitrate mg/L ■❑ Nitrate less than MRL (ND) Arsenic 12.0 ug/L ❑ Arsenic less than MRL (ND) Collected by GEG, LTD. Date of Sample 12/27/19 & 1/3/20 C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Comments: N/A Adequacy test date 12'26119 Results Q✓ Pass For 3 bedrooms Fluid depth prior to test 6 in Water added 536 gal New depth 7 in Elapsed time 120 min Final fluid depth 4 Ir4rA Absorption rate 4�� gpd Any rejuvenation treatment (past 12 months) *UNK If yes, enter date N/A E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' E] Yes *68Community Sewer Manhole/Cleanout > 100' ❑ Yes if No ft 0 Yes if No ft Neighboring Tank > 100' 0 Yes if No ft Private Sewer/Septic Line > 25'2] Yes if No ft Absorption Field on Lot > 100' ❑ Yes if No **95 ft Holding Tank > 100' ❑✓ Yes if No ft Neighboring Absorption Fields > 100' Animal Containment > 50' Q✓ Yes if No ft El Yes if No ft Manure/Animal Excreta Storage > 100' —❑✓ Community Sewer Main > 75' Q✓ Yes if No ft Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) ***5+ Building Foundations > 10' [J Yes if No ft Surface Water > 100' 0 Yes if No ft Property Line > 5' E] Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' El Yes if No ft Private Wells > 100' Yes if No ft Water Main > 10' 0 Yes if No ft Community Wells > 200'✓❑ Yes if No ft Water Service Line > 10' El Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Yes if No ft If absorption field is under driveway comment below Property Line > 10' Yes if No ft Wells on Adjacent Lots: Water Main > 10' Q Yes if No ft Private Wells > 100' Yes if No ft Water Service Line > 10' Q Yes if No ft Community Wells > 200' Q Yes if No ft Surface Water > 100' Q Yes if No ft F. ENGINEER'S COMMENTS *TANK INSTALLED 7/1973. MET SEPARATION DISTANCE AT TIME OF INSTALLATION **WAIVER GRANTED (SEE WR #101051). ***MET SEPARATION DISTANCE AT TIME OF INSTALLATION. NO FOUNDATION CLEAN-OUT (SEE MAY 2010 COSA). G. ENGINEER'S CERTIFICATION 00006oO X00 I certify that 1 have determined through field inspections and review O of Municipal records that the above systems are in conformance with Opp T MOA COSA guidelines in effect on this date. , , , ,, , , , , f , ,,,,,,,, , , , , , , , , , • ,� 0•' 1. ...... ........... QO effr A. Gar ess:' Q 9,• C 795• �4 �q 4 4 ire •• .....• ��°p COSA Checklist yellow sheet 4� a Pro f e ssxor°oma #AECC884 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT i 907-343-7904 On -Site water and wastewater Section s Fax: 343-7997 WWW.MLini.org/onsite Arsenic Advisory Certificate of On -Site Systems Approval # OSC2O1O67 Subdivision: T15N R1W Sec.19 Lot 23 A water sample revealed an arsenic concentration of 12 micrograms per liter (ug/L). The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Information on arsenic is available from the On -Site Water and Wastewater Program website (www.muni.org/onsite) or at 343-7904. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. Mailing Address P O Box 196650 * Anc�iorage, Alaska 99519 6650 7 www muni org S ENGINEERING oSALES- CONSULTING March 4, 2020 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Ref: Conditional COSA Request for TI 5N R1 W Sec19; Lot 23 To whom it may concern: The subject property needs a tank replacement and a permit was approved on 2/14/20. The previously mentioned work is to be completed in spring/summer of 2020. We are unaware of any environmental or health risks associated with delaying the tank install until the spring/summer of 2020. Attached with the COSA were quotes for the proposed work as well as the required escrow letter. If you have any-lquestions, please contact us at 337-6179. Thank you for your assistance. ( Sincerelv. P ! I P. E., M.S. 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com RESIDENTIAL MnRTGAC�F I I C NMLS #167729 100 Calais Drive Anchorage, Alaska 99503-4049 (907) 222-8800 phone (907) 222-8801 fax 1-888-357-2707 toll free www.residentialmtg.com March 5, 2020 Municipality of Anchorage On-site Water and Wasterwater Progam PO Box 196550 Anchorage, AK 99519-6650 Re: Permit #OSC201067 Well/Septic Parcel #05124102000 To Whom It May Concern: Residential Mortgagage will be holding an escrow in the amount of $11,400 to ensure completion of the installation of a new septic tank and the raising of monitoring tubes. Attached please find a copy of the estimate and scope of work from Red Dog Masony, Inc. Residental Mortgage will not release any escrow funds without written approval from the MOA. Please call me if you have any questions, Denise J. Long Sr. Vice President (907)222-8812 ph longd@residentialmtg.com 1