ON-SITE WASTEWATER INSPECTION REPORT 4
0
Permit Number: OSP201021 PID Number: 051-241-02 �0
Dwelling: 0 Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New 0 Upgrade
Name
LINDA EVANS
PTION FIELD
Pr_1 Trench ❑Wide Trench ❑Bed ound
OtherPhoneof
Site Address
18920 SPRUCE CREST DRIVE, EAGLE RIVER, AK 99577
360-6691
Bedrooms
3
/SF
Total depth f original grade
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from orig
EXISTING
depth beneath pipe
Ft.
Subdivision Block Lot
- - 23
Fill added above original gr IGnh
Ft. Ft.
Township Range Section
15N 1 W 19
Gravel width
Ft.
Beds: Number of Lines
Dista between lines
Ft.
SEPARATION DISTANCES
To
From
Septic
Tank
Absorption
Field
Lift Station
Holding
Tank
Sewer
Line
Total orption area
Ft2
Number of trenches
Dist. between t ches
Well
*78'
EXISTING
_
_
25'+
TANK ❑e Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
GREEK TANK
Capacity
1000 Gal.
Surface Water
100'+
EXISTING
_
_
Material
Number of compartments
Lot Line
rj'+
EXISTING
_
_
NA
HDPE PLASTIC
2
Foundation
10'+
EXISTING
_
_
L kTION
Manufacturer Capacity
Remarks *PHYSICALLY MEASURED. 75' WELL WAIVER
Gal.
GRANTED (WAIVER # OSV201007)
Alarm location Electric fled by
Installer
RED DOG MASONARY
PIPE MATERIAL House to tank ABS F628 Tank to ABS F628
(FOR NEW) dralnfleld (FOR NEW)
Drainfield EXISTING CO/MT ABS F628
Inspector JODY MAUS, GEG CONSULTANT
BENCH MARK (Assumed elevation) 100.00 ft
Inspdectio v, 6/23/2020 Zia -
3"' - 4th _
Location and description
BOTTOM OF SIDING @ NE CORNER OF HOUSE
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
Conditional Approval: Date
060
4_7 �o�.
y�J *C'). • 4. T, �*�Q
f/'...... .. .A . . ......
�--✓ J.. . r ....�
O f ,A r
.: �r y Ga SS. �p
dp9 f IJ c -7p53 Op
1f � Pre �}'.
#AECC884 OO�OppO�
Septic System
ApprovedY211t&M Date g t da��
Note: this approval does not include well permit requirements.p,°fes5°�°oma
PERMIT NUMBER: PARCEL ID NUMBER:
OSP201021 RECORD DRAWING 051-241-02
NOTE: OLD SEPTIC TANK
WAS COMPLETELY
REMOVED AND DISPOSED
OFFSITE PER CONTRACTOR
0
0)
z
0
P
w
z
F-
— — — — — — — — — — — — —
SPRUCE CREST DRIVE
NEW 1,000 GALLON HOPE GREER TANK
INSTALLED DOUBLE
CLEANOUTS (DBL3 & D
EXISTING LOG CRIB. PASSED SEPTIC ADEQUACY
TEST ON 12/26/2019. CONTRACTOR EXTENDED
MONITORING TUBE 12" ABOVE GRADE -7
-IT OF WAY FOR
ND PUBLIC UTILITIES
INSTALLED DOUBLE
MT CLEANOUTS (DBL1 & DBI -2)
A
7
EXISTING
3 BED OM
O'A HOUSE
0
41
EXISTING WELL
100' WELL RADIUS
I A I B C
DBLI 37.8 1 7.4 33.4
DBL2
39.3
1 9.3
35.4
MH
-97 -1
45.6
1 17.3
42.9
49.2
1 21.6
47.1
6-55
-5-2-2-T
2-5.3
50.6
E-BL254�.327.4
ENGINEERING SALES, CONSULTING -,
10
525
VT-
71.7
1 44.0
67!5
N
SCALE:
......
........
#
GARNEIS'" EN(ff Erd k�i
-ANT-1 RIN'
'-N R
olr Tp Ltd
Vi u Ltd
0 ..... 9
. .... ..
......... ...........
ENGINEERING SALES, CONSULTING -,
10
3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507 - PHONE (907) 337-6179 - FAX (907) 338-3246 • WEBSITE: www-gamessenginee6ng.00M
............
•
..............
j4L
PREPARED
FOR:
LINDA EVANS.:
PHONE NUMBER:
907-360-6691
PAGE NUMBER:
20F3
mess
0
E- 5 !;� Alr
AV
4w
0 ... .... 41p
I
PROJECT/LEGAL DESCRIPTION:DRAWN
Tl 5N Rl W SECTION 19 LOT 23
BY:
J.L.M.
TYPE OF WORK:
DATE:
RD DRAWING OF SEPTIC TANK UPGRADE
O�
�,_�
7/6/2020
NSE
LICE IL
#AE C884
PERMIT NUMBER: PARCEL ID NUMBER:
OSP201021 RECORD DRAWING 051-241-02
FINAL GRADE
TOP OF MH LID = 98.98 = 98.83-98.90
MH
TOP TANK I I TOP OF OUTLET =94.71
INLETT = 94.73- @
INVERT OF BUNG
@ INLET = 94.08 —/ NEW 1000 GALLON INVERT OF BUNG
GREER HDPE @ OUTLET = 93.91
SEPTIC TANK
OF
�_._cP.••
GAR ESS ENGINEERING G ROUP, Ltd 4 ••••... � ..•••
ENGINEERING SALES CONSULTING .....••/ •••0
3701 E. TUDOR ROAD, SUITE 101 ' ANCHORAGE, AK 99507' PHONE (907) 337-6179 • FAX (907) 338-3246WEBSITE: www.gamessengineedng.00m ,� ... .......... ........�.,y.,,;
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: C� :, A. Gar SS
LINDA EVANS 907-360-6691 3 OF 3
Cl;- 53 ' ?�
PROJECTlLEGAI DESCRIPTION: DRAWN BY:
Tl 5N R1 W SECTION 19 LOT 23 J.L.M. Fp••'••• .......
,�,�,,\\
TYPE OF WORK: DATE:
�,_
RECORD DRAWING OF SEPTIC TANK UPGRADE 7/6/2020 # LICENSE
r',p 4%��is��'�
. �
Lot 205-A | Lot 205-8 |
___ _____________________ . . __ _ ___ ' |
___._______
EDGE or ROAD SPRUCE CREST DRIVE
��,,a6'
CONC. PORCH
/ \_
WITH FUEL TANK BELOW�
\
|
nr 5.9' SHED
IL
/
\
~~
12' " `z HORSE STALL
Lot 23
1o8,y00a�
| w oynnno'n 32945'
|
Lot 25 L� ��
60
|
PLOT PLAN AS BUILT SCAL(IlL-=� �5CV GRID NW 9.54 proje
11500 Daryl Avenue. Anchorc
Lang OR Associafes, inc. (907) 522-6476 Phone
(907) 522-4625 Fox
Professional Land Surveyors ken0longsurvey.com
I hereby cariffy that I have surveyed the following described property:
Lot 23, SECTION 19, T15N. R1W. SEWARD MERIDIAN, ALASKA
Anchorage Recording District, Alaska, and that the Improvements situated thereon are
within the property lines and do not encroach onto the property adjacent thereto, that
no Improvements on the property lying adjacent thereto encroach on the surveyed
premises and that there are no roadways, transmission lines or other visible
easements on sold property except as Indicated hereon.
Dated this the __���_ oq, of . ����_. at Anchorage, mnsxm
it Ism* responsibility of the owner :, determine the existence of any ments.
on,enomm, or restrictions which do not appear on the recorded subdivision plot.
W
|
Lot 27D
'
sEPncnpES-»-
/
ROADWAY AND PUBLIC UTILITES
/
, STORY
z
/
ess/mENcc
'
9.+' , 12.1' GREENHOUSE
WITH DAYLIGHT
\
`
BASEMENT
/
m',3.3'-/
+
|
CANT
\
\
\
` ^
\`
/ \_
WITH FUEL TANK BELOW�
\
|
nr 5.9' SHED
IL
/
\
~~
12' " `z HORSE STALL
Lot 23
1o8,y00a�
| w oynnno'n 32945'
|
Lot 25 L� ��
60
|
PLOT PLAN AS BUILT SCAL(IlL-=� �5CV GRID NW 9.54 proje
11500 Daryl Avenue. Anchorc
Lang OR Associafes, inc. (907) 522-6476 Phone
(907) 522-4625 Fox
Professional Land Surveyors ken0longsurvey.com
I hereby cariffy that I have surveyed the following described property:
Lot 23, SECTION 19, T15N. R1W. SEWARD MERIDIAN, ALASKA
Anchorage Recording District, Alaska, and that the Improvements situated thereon are
within the property lines and do not encroach onto the property adjacent thereto, that
no Improvements on the property lying adjacent thereto encroach on the surveyed
premises and that there are no roadways, transmission lines or other visible
easements on sold property except as Indicated hereon.
Dated this the __���_ oq, of . ����_. at Anchorage, mnsxm
it Ism* responsibility of the owner :, determine the existence of any ments.
on,enomm, or restrictions which do not appear on the recorded subdivision plot.
W
|
Lot 27D
33' RIGHT-OF-WAY FOR
ROADWAY AND PUBLIC UTILITES
'
9.+' , 12.1' GREENHOUSE
\
`
/ \_
WITH FUEL TANK BELOW�
\
|
nr 5.9' SHED
IL
/
\
~~
12' " `z HORSE STALL
Lot 23
1o8,y00a�
| w oynnno'n 32945'
|
Lot 25 L� ��
60
|
PLOT PLAN AS BUILT SCAL(IlL-=� �5CV GRID NW 9.54 proje
11500 Daryl Avenue. Anchorc
Lang OR Associafes, inc. (907) 522-6476 Phone
(907) 522-4625 Fox
Professional Land Surveyors ken0longsurvey.com
I hereby cariffy that I have surveyed the following described property:
Lot 23, SECTION 19, T15N. R1W. SEWARD MERIDIAN, ALASKA
Anchorage Recording District, Alaska, and that the Improvements situated thereon are
within the property lines and do not encroach onto the property adjacent thereto, that
no Improvements on the property lying adjacent thereto encroach on the surveyed
premises and that there are no roadways, transmission lines or other visible
easements on sold property except as Indicated hereon.
Dated this the __���_ oq, of . ����_. at Anchorage, mnsxm
it Ism* responsibility of the owner :, determine the existence of any ments.
on,enomm, or restrictions which do not appear on the recorded subdivision plot.
W
|
Lot 27D
12' " `z HORSE STALL
Lot 23
1o8,y00a�
| w oynnno'n 32945'
|
Lot 25 L� ��
60
|
PLOT PLAN AS BUILT SCAL(IlL-=� �5CV GRID NW 9.54 proje
11500 Daryl Avenue. Anchorc
Lang OR Associafes, inc. (907) 522-6476 Phone
(907) 522-4625 Fox
Professional Land Surveyors ken0longsurvey.com
I hereby cariffy that I have surveyed the following described property:
Lot 23, SECTION 19, T15N. R1W. SEWARD MERIDIAN, ALASKA
Anchorage Recording District, Alaska, and that the Improvements situated thereon are
within the property lines and do not encroach onto the property adjacent thereto, that
no Improvements on the property lying adjacent thereto encroach on the surveyed
premises and that there are no roadways, transmission lines or other visible
easements on sold property except as Indicated hereon.
Dated this the __���_ oq, of . ����_. at Anchorage, mnsxm
it Ism* responsibility of the owner :, determine the existence of any ments.
on,enomm, or restrictions which do not appear on the recorded subdivision plot.
W
|
Lot 27D
MUNICIPALITY OF ANCHORAGE „C„r
On -Site Water & Wastewater Program �o� Is,
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite v
Department
On -Site Wastewater Disposal System Permit
Permit Number: OSP201021 Effective Date: 2/14/2020
Work Type: SepticTank Upgrade Expiration Date: 2/13/2021
Tax Code Number: 05124102000
Site Legal Address: T15N R1 W SEC 19 LT 23 G:0954
Site Mailing Address: 18920 SPRUCE CREST DR, Chugiak
Owner: EVANS LINDA Lot Size in Sq Ft: 108900
Design Engineer: GARNESS ENGINEERING GROUP LTD Total Bedrooms: 3
This permit is for the construction of:
❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
tovered, sealed, and heated to prevent freezing
ial Provisions: Contractor shall locate new septic tank as far from the well as possible, but maintain
um 5 ft separation to existing drainfield.
Received B�
Issued By:
Date: r
Date:
' liltTl(_ s
-Municipa' ity: ®f Anchorage _ c .N
Depart Wilt
P.O. Box 196650 ® 4700 Elmore Road
Anchorage, Alaska 99519-6650 O (907) 343-7904 m Fax (907) 343-7997
hftp://www.muni.org/Onsite
Development'Services Department
On -Site Water and Wastewater Section
* * * * 'VARIANCE/WAIVER REVIEW * x * *
Waiver#: OSV201007 COSA#: Permit#:OSP201021
PID#: 051-241-02
Legal Description: T15N R1W Section 19 Lot 23
Engineer: Garness Engineering Group
Applicant: Linda Evans
Your request for a waiver of the required 100 feet horizontal separation from the septic tank to
the private well has been approved. The approved separation distance is 75.0 feet. See engineer's
waiver request for justifications.
This waiver approval applies to the proposed septic tank only. Any future upgrade to the on-site
wastewater disposal system will require all separation distances be met or another approval from
this department.
......................................................................... 9 N 0 N R i
Waiver is Granted: X Waiver is not Granted:
Date:
LIZ11, _ZXa� Approved by: 7Q,
l Name of Reviewer
■ ■ ... t .. ■ ■ ■ ■ ■ ■ 1 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 9 x K ■ ■ ■ ■ ■ . ■ t t ■ ■ ■ ■ .. ■ ■ ■ ■ ■ ■ ■ . t ■ ■ ■ ■ ■ 1 t ■ ■ ■ ■ ■ ■ t ■ ■ ■ 1 t ■ ■ t
**** VARIAN C E/WAIVER REVIEW ****
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Fax: 907- 343-7997
On -Site Water & Wastewater Program
Mayor Dan Sullivan
On -Site Sewer[Well Permit Application
For A Single Family Dwelling
Parcel I.D. 051-241-02
Property owner(s) LINDA EVANR5 Day phone 907-360-6691
Mailing address 18920 SPRUCE CREST DRIVE *CHUGIAK, AK 99567
Site address 18920 SPRUCE CREST DRIVE *CHUGIAK, AK 99567
Legal description (Sub'd, Block & Lot ) LOT 23
Legal description (Township, Section & Range) T15N, R1 W, SECTION 19
Lot Size
APPLICATION IS FOR:
IN all that apply)
Absorption Field
❑
Septic Tank
Holding Tank
❑
Privy
❑
Private Well
❑
Water Storage
❑
Sq.Ft. Number of Bedrooms 3
APPLICATION IS AN:
Initial ❑
Upgrade
Renewal ❑
THIS APPLICATION INCLUDES A VARIANCE/ WAIVER REQUEST FOR:
WELL TO SEPTIC TANK
TYPE OF DEWELLING:
Single Family (SF)
(w/wo ADU)
Duplex (D) ❑
Multiple Dwellings ❑
(SF and/or D)
Distance: 75 FEET
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
(Signature of property owner or authorized agent)
Permit/Rush Fees: aas Waiver Fees: it 1:36
Date of Payment: V11,319oa6 Date of Payment:
Receipt Number: ()(g6;Zg6 Receipt Number:
Permit No. (15P loaf Waiver No. V
(Rev. 01111)
GARNESS ENGINEERING GROUP, Ltd
- ENGINEERING SALES CONSULTING - -
January 8, 2020
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Ref: Proposed Septic Tank Upgrade for T15N, R1 W, Section 19, Lot 23
To whom it may concern:
The subject lot is served by a private well and septic system. Per MOA records, the existing
steel septic tank is approximately 46 years old. Per MOA memorandum, a steel septic tank of
this age must be physically inspected and/or replaced prior to COSA approval. Based upon this
fact, we are proposing to replace the septic tank. We are proposing that the old septic tank be
decommissioned per UPC and a new 1000 -gallon HDPE Greer tank (rated for 10' burial) be
installed. See attached design drawings for the tank location and other MOA requirements. As
can be seen on the attached design drawing, we are requesting a 75 -foot waiver from the well
to the new septic tank. The old septic tank was installed in 1973 when the separation distance
was only 50 feet. The old septic tank is approximately 68 feet from the well. We have recently
pulled water samples for Total Coliform Bacteria, Nitrate and Arsenic from the well. Attached are
the lab results and based upon these results, it appears there has been no adverse effects on
the well with the existing encroachment. The well head is also at a higher elevation than the
grade at the septic tank. In short, there appears to be minimal risk with the granting of this
waiver.
We would like to note that the MOA Public Inquiry Property Detail website, the house is listed as
a 4 -bedroom residence. However, based upon the 2010 appraisal the house is a 2 -bedroom
residence (see attached). The original septic system was installed for a 3 -bedroom residence.
Per the owner, they are requesting the new septic tank be sized for a 3 -bedroom residence.
We are unaware of any adverse impacts this installation would have on adjacent wells or septic
systems. If you have any questions, please contact us at 337-6179. Thank you for your
assistance. A
rely,
Pres
, P.E., M.S.
3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
T15N, R1 W,
SECT 19, LOT 24
Qoo
CSETicO
AR�
T15N, R1 W, SECT. 19, LOT 25
NO ENCROACHMENT CONCERNS
T15N, R1W, SECT. 18,
,,, LOT 205-A
I
I
I
I
I
I
I
I
I
I
I
I
I
---------------
I
I
I
i EPTIC
AR�D I
------------�-+-�-p--------------�+1T--�-p �VE
,C
--------i?r-'r�CV V- -Q7"[ - T- -B R VE -------
PROPOSED NEW
- - SEPTIC TANKS - - ' - - — - ��`•^ - - —
T15N, R1 W, SECT. 18, LOT 206
NO ENCROACHMENT CONCERNS
EXISTING
SEPTIC
1
EXISTING
, 3 BEDROOM
! HOUSE
ARNOLDS; LOT 26A
VACANT PER MOA RECORDS
GARNESS ENGINEERING GROUP, Ltd
ENGINEERING o SALES o CONSULTING -
3701 E. TUDOR ROAD, SUITE 101 -ANCHORAGE, AK 99507' PH(*E (907) 337-6179' FAX (907) 338-3246 • WEBSITE: www.gamessengineedng.com
PREPARED FOR:ONE NUMBER: PAGE NUMBER:
LINDA EVAN T
H907-360-6691 1 OF 2
PROJECT/LEGAL DESCRIPTION: DRAWN BY:
T15N R1 W SECTION 19 LOT 23 D.J.G.M.L.M.
TYPE OF WORK. DATE:
�, SITE PLAN FOR SEPTIC TANK UPGRADE 12/27/2019
T15N, R1 W, SECT. 19, LOT 22
NO ENCROACHMENT CONCERNS
W O
N
SCALE:
1"=100'
ARNOLDS; LOT 27D
NO ENCROACHMENT CONCERNS
F-1
All,,�P••••. ..•,•• •• ♦♦
AV
........ ...... ..... ...0
0
♦�g' .•Gar ess".• 41 i
�'. '"2
CE -79 3 .�••� Ar
AV
LICENSE
#AECC884 \\\\\� j
GEG, Ltd. HAS AN 8 PAGE SPECIFICATION LETTER
THAT PERTAINS TO THIS DESIGN. BY PROCEEDING
FORWARD WITH THIS INSTALLATION, THE
ENGINEER, WELL DRILLER, CONTRACTOR AND
PROPERTY OWNER AGREE THAT THEY HAVE
READ THESE SPECIFICATIONS AND AGREE TO
ACCEPT THE TERMS AND CONDITIONS OUTLINED.
-----------------
SPRUCE
----------------
SPRUCE CREST DRIVE
PROPOSED 1,0000 GALLON HDPE GREER TANK
RATED FOR 10' BURIAL; INSTALL DOUBLE
EFORE AND AFTER TANK
EXISTING LOG CRIB. PASSED SEPTIC ADEQUACY —
TEST ON 12/26/2019. CONTRACTOR TO EXTEND
MONITORING TUBE 12" ABOVE GRAD _
EXISTING SEPTIC TANK
(COLLAPSING). TO BE
DECOMMISSIONED PER UI
C
* •' ;
33' RIGHT OF WAY FOR
\
,'%.d
INSTALL NEW
_
•'•• �'
FOUNDATION
CLEANOUT
\
N
\
I
I
()
IJ
I
z
O
F-
0 U
Iw
�
I
z
H
/
s
-----------------
SPRUCE
----------------
SPRUCE CREST DRIVE
PROPOSED 1,0000 GALLON HDPE GREER TANK
RATED FOR 10' BURIAL; INSTALL DOUBLE
EFORE AND AFTER TANK
EXISTING LOG CRIB. PASSED SEPTIC ADEQUACY —
TEST ON 12/26/2019. CONTRACTOR TO EXTEND
MONITORING TUBE 12" ABOVE GRAD _
EXISTING SEPTIC TANK
(COLLAPSING). TO BE
DECOMMISSIONED PER UI
C
I \ \ \ u / / I
I
\ NOTE: THE CONTRACTOR SHALL HAVE THE 75 FOOT
WELL RADIUS FLAGGED/STAKED BY A REGISTERED
LAND SURVEYOR PRIOR TO CONSTRUCTION.
GARNESS ENGINEERING GROUP, Ltd
-- _� ENGINEERING o SALES - CONSULTING -- --_
3701 E. TUDOR ROAD, SUITE 101 ' ANCHORAGE, AK 99507' PHONE (907) 337-6179' FAX (907) 338-3246' WEBSITE: www.gamessongineering.com
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
LINDA EVANS 907-360-6691 2 OF 2
PROJECT/LEGAL DESCRIPTION: DRAWN BY:
Tl 5N R1 W SECTION 19 LOT 23 D.J.G.M.L.M.
TYPE OF WORK: DATE:
�, DESIGN OF SEPTIC TANK UPGRADE 12/27/2019
%IS!
OF
•q
ey..�..Gar. ess.:'�
�1���• C -79 ZO
LICENSE 41S1;`,lkk ����`..•o
#AECC884
* •' ;
33' RIGHT OF WAY FOR
ROADWAY AND PUBLIC UTILITIES
,'%.d
INSTALL NEW
_
•'•• �'
FOUNDATION
CLEANOUT
\
NG WELL
\
I
I
I \ \ \ u / / I
I
\ NOTE: THE CONTRACTOR SHALL HAVE THE 75 FOOT
WELL RADIUS FLAGGED/STAKED BY A REGISTERED
LAND SURVEYOR PRIOR TO CONSTRUCTION.
GARNESS ENGINEERING GROUP, Ltd
-- _� ENGINEERING o SALES - CONSULTING -- --_
3701 E. TUDOR ROAD, SUITE 101 ' ANCHORAGE, AK 99507' PHONE (907) 337-6179' FAX (907) 338-3246' WEBSITE: www.gamessongineering.com
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
LINDA EVANS 907-360-6691 2 OF 2
PROJECT/LEGAL DESCRIPTION: DRAWN BY:
Tl 5N R1 W SECTION 19 LOT 23 D.J.G.M.L.M.
TYPE OF WORK: DATE:
�, DESIGN OF SEPTIC TANK UPGRADE 12/27/2019
%IS!
OF
•q
ey..�..Gar. ess.:'�
�1���• C -79 ZO
LICENSE 41S1;`,lkk ����`..•o
#AECC884
SGS Ref.#
Printed Datetrime 01/08/2020 9:16
Collected Date/Time 12/27/2019 7:46
Received Date/Time 12/27/2019 8:44
Technical Director Stephen C. Ede
1197497001
Client Name
Garness Engineering Group, Ltd (GEG)
Project Name/#
T15N,R1 W,Sec 19,Lot 23
Client Sample ID
T15N,R1 W,Sec 19,Lot 23
Matrix
Drinking Water
Sample Remarks:
Allowable Prep Analysis
Parameter Results LOQ Units Method Container ID Limits Date Date Init
Metals by ICP/MS
Arsenic
Waters Department
Total. Nitrate/Nitrite-N
12.0 * 5.00
ND 0.200
ug/L
EP200.8
B
(<10)
01/03/20 01/06/20 BMZ
mg/L
SM21 450ONO3-F
C
(<10)
01/03/20 EWW
SGS Ref.#
1200029001
Client Name
Garrtess Engineering Group, Ltd (GEG)
ProjectName/lt
T15W,R1W,SECl9,LOT23
Client Sample ID
T15W,R1 W,SECI9,LOT23
Matrix
Drinking Water
Sample Remarks:
Printed Date/Time
Collected Date/Time
Received Date/Time
Technical Director
01/08/2020 16:00
01/03/2020 7:18
01/03/2020 10:56
Stephen C. Ede
Allowable Prep Analysis
Parameter Results LOQ Units Method Container ID Lits Date Date Init
Microbiology Laboratory
E. Coli Negative I 100mL SM21 9223B A 01/03/20 VAB
Total Coliform Negative I IOOmL SM21 9223B A 01/03/20 VAB
<0 v a 0 > e r
— u ® ten s r
�w C_ 333o
acc® i t
w 00 CD
CDS S
m
0 mit
O' rt 00
icr _-i O a O S
O
�3ZO
o�smo"co t
u®, vm®mom S
m i < U
-, 0, ® <
m Q ® O V r- V/
Sp " swcaop-D�c Q
p.a 0
O ®O a ® CL —
p"C ^o
a Q
0 0 Q y IE w
_ 0 a Do–
Q.
m T
�m!y aI piOD® ( ]
Ij p•" ..0.. O � - '^
03 eam=r <
3 aZao mE CD
-+ ( �ir
3=OwotO Q ®®
O s mF 3 Z w i
s D a o w�" n C) I'
� x " a>I ,
O GO s��m`��
a i � T� u � 0 ®jLn
00.
o o ®0
®vv t
® S' O
CT aO p —
0. a p m a p C a tp N N
<� �Smnoo O�Ntaa
p p a (A ® 0- (0 0 0) �► D
am -1 ®0S� snU�iOvim !
3 0 w O
m '4 C
f0 `< .mr O "C -q T
® 0 0 a O 0 S.
O
s° 3 ® n
0
O i
p � s
r
0 ( vz IOl
iLn_ ,6b'8Z£ M Q£,Z 1.00 N
m
/ m
CD
l
D pm p
I z�nl�
r
I
j
�DOa . 'a m:
1
00
> Ln
00
Q
PA Co
I� O0 D
PA
OV5
:I�
(J�
W
p sG'•
''Gj�O
d
\
r
0 ( vz IOl
iLn_ ,6b'8Z£ M Q£,Z 1.00 N
m
/ m
CD
l
D pm p
I z�nl�
r
I
j
® Z
1
00
> Ln
00
W
N
to
'146
-
c
m"
\
r- P,
D �
2
\
�
7c O
\\
J
m
O x
x
=-
Ln
co O ®
n
to
0
o �
to
,tb6'SZ£ 3„00,61.00 S
zz }®1
i
r*3
0
m
m 11
0
M
0
0
Ln
0
C
:n o
co m\ J
O_
N
Q
Ln
i
Municipality ®f AnchorageO
On -Site Water and Wastewater Program 44
(907) 343-7904
Certificate of On -Site Systems Approval
Parcel I.D. 051-241-02 Expiration Date: Oa D
1. GENERAL INFORMATION:
Complete legal description T15N, R1 W, SECTION 19: LOT 23
Location (site address) 18920 SPRUCE CREST DRIVE, CHUGIAK, AK 99567
Current Property owner(s) LINDA EVANS Day phone 907-360-6691
Mailing address 18920 SPRUCE CREST DRIVE, CHUGIAK, AK 99567
Real Estate Agent NICHOLE PERRY W/ KELLER WILLIAMS Day phone 865-6557
2. TYPE OF DWELLING:
Z Single Family (w/wo ADU)
❑ Duplex
1771 Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS:
3
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
Individual
N
Individual Water Storage
❑
Holding Tank
1771
Community Class Well
0
Community
E71
Public Water System
E71
Public Sewer
0
WaiverNariance request for: Distance:
Received by:
COSA to be released to the engineer, unless otherwise requested by the engineer,
COSA Fee $
Date of Payment oZ a C)a C)
Receipt Number 015(06
COSA # 0 S C- 20 1 OV -7
Date:
Waiver Fee $
Date of Payment
Receipt Number,
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179
Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507
Engineer's Printed Name: Jeffrey A. Garness Date:�fT?�
In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system o O�r At
in accordance with the guidelines and regulations established by the Municipality of Anchorage and
industry practices. The reported results describe the condition of the system/s on the date/s of the
evaluation. Separation distances were measured to readily identifiable features. Hidden defects or /.
encroachments may exist that were not identified during the evaluation. The operational life of all wells '•7�
and septic systems depend upon a variety of variables, including but not limited to, soil conditions, • • • • ;• . . • • • • • • • • • . • • .
groundwater levels (that may fluctuate during the year), quality of construction (materials and
workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and . . ....... .......
are outside the control of GEG. Satisfactory test results do not guarantee future performance of the �/1 eftr Gorness•r
system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of Vn CE 953 `
the well or septic system. GEG makes no representation whether an alternative well or septic system !�
can be installed on the property in the event either of the current systems fail to perform adequately in
the future. The content of this report is for the sole benefit of the person/party that retained GEG to a p�ofessto�
o
perform the evaluation. Reliance upon the information provided in this report by any other person or
party (including subsequent property purchasers) is not authorized, nor will it confer any legal right
whatsoever.
#AECC884
6. DSD SIGNATURE
J System #1 Approved for 3 bedrooms
System #2 Approved for bedrooms
Disapproved
Conditional approval for bedrooms,
OF
.I�F.V Ov _S�TE
+;
sR
���
with the followir> sfipul)ii%;!ATER O
9ROGF.AM
7))j) ))) W)"i))�,
By: Original Certificate Date:1 ' v' D
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist_ Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet_10-10-12.doc
COSA Checklist
Legal Description: T15N, R1W, SECTION 19; LOT 23
If more than 1 septic system on lot: COSA Checklist # 1 of 1
A. WELL DATA
FE -1 Well log is filed with Onsite (or attached)
Date drilled 7120/73
Total depth 111 ft
Cased to 81 ft
R Sanitary seal is functioning correctly
R Wires are properly protected
Casing height (above ground) 12+ in.
Date of flow test for COSA 2/19/20
Static water level at beginning of test *44.0 ft.
Comments *ON 12/26/2019
B. TANK DATA
Age of tank(S) NEW years
Tank type/material HDPE
Measured operating fluid level in septic tank NEW
11011 Standpipes/foundation cleanout per record drawing
Date of pumping NEW
D. ABSORPTION FIELD DATA SEEPAGE PIT
Which system tested (date installed) 7/73
140 ALL standpipes present per record drawing
Total measured depth from grade 8.9 ft (max)
Measured depth to pipe invert from grade 4.3 ft (min)
❑ N/A — pressurized field
Monitor tubes go to bottom of effective. If not, state
depth into effective
Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced N/A gallons
Comments/Deficiencies:
COSA Checklist yellow sheet
Parcel ID: 051-241-00
Structure served by this system 1
Well production at time of test 2 1 gpm
Water storage tank volume 400 gallons
Well disinfected for coliform test? ❑ Yes No
❑■ Coliform bacteria is Negative
Nitrate mg/L 0 Nitrate less than MRL (ND)
Arsenic 12.0 ug/L ❑ Arsenic less than MRL (ND)
Collected by GEG, LTD.
Date of Sample 12/27/19 & 1/3/20
STATION
❑ Require6�
Age of lift station
Lift station material
Comments✓
co
Adequacy test date 12126119
Results Q✓ Pass For 3 bedrooms
Fluid depth prior to test 6 in
Water added 536 gal
New depth 7 in
Elapsed time 120 min
Final fluid depth 4 in
Absorption rate 450+ gpd
Any rejuvenation treatment (past 12 months) " UNK
If yes, enter date N/A
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'Community
S Yes
*75+
Sewer Manhole/Cleanout > 100'
rJ Yes
if No
ft
(Q Yes
if No ft
Neighboring Tank > 100' R Yes
if No
ft
Private Sewer/Septic Line > 25' Yes
if No ft
Absorption Field on Lot > 100' ❑ Yes
if No
**95 ft
Holding Tank > 100' Yes
if No ft
Neighboring Absorption Fields > 100'
if No
ft
Animal Containment > 50' Yes
if No ft
F/1 Yes
if No
ft
ft
If septic tank is under driveway
comment below
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' 21 Yes
if No
ft
P1 Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
S Yes
if No
ft
Surface Water > 100'
Yes if No ft
Property Line > 5'
R Yes
if No
ft
Wells on Adjacent Lots:
Wells on Adjacent Lots:
Absorption Field > 5'
Q Yes
if No
ft
Private Wells > 100'
Yes if No ft
Water Main > 10'
Yes
if No
ft
Community Wells > 200'
0 Yes if No ft
Water Service Line > 10'
Yes
if No
ft
If septic tank is under driveway
comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
Q44 .
Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
Q
Yes
if No
ft
Wells on Adjacent Lots:
Water Main > 10'
Q
Yes
if No
ft
Private Wells > 100' Yes if No ft
Water Service Line > 10'
Yes
if No
ft
Community Wells > 200' El Yes if No ft
Surface Water > 100'
Q
Yes
if No
ft
F. ENGINEER'S COMMENTS
*WAIVER GRANTED (OSV201007)
**WAIVER GRANTED (SEE WR #101051).
G. ENGINEER'S CERTIFICATION
/ certify that / have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
COSA Checklist yellow sheet
VO y Gar........ss.:...
Q44 .
CE 79 3 ��
#AECC884
0
io�°o
rofess��DOO000�
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT / 907-343-7904
On -Site water and wastewater Section Fax: 343-7997
www.muni.org/onsite
Arsenic Advisory
Certificate of On -Site Systems Approval # OSC201067
Subdivision: T15N R1W Sec.19 Lot 23
A water sample revealed an arsenic concentration of 12 micrograms per liter
(ug/L). The Environmental Protection Agency (EPA) has established a maximum
contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While
private wells are not subject to this regulation, EPA standards are based on existing
health information and can therefore be used to gauge the relative quality of water
from private wells. Information on arsenic is available from the On -Site Water and
Wastewater Program website (www.muni.org/onsite) or at 343-7904.
This advisory must be attached to all copies of the subject Certificate of On -Site
Systems Approval.
�lail�ng Ac�dress� P O Box 196650* Anchorage Alaska 99519 6650 * www�mum org � ��
x
Municipality of Anchorage �
On-Site Water. and Wastewater Program
(907) 343-7904 S X C T YN
LE
Certificate of On-Site Systems Approval
LZ
Parcel I.D. 051-241-02
1. GENERAL INFORMATION:
Complete legal description T15N, R1W, SECTION 19; LOT 23
Expiration Date:
Location (site address) 18920 SPRUCE CREST DRIVE, CHUGIAK, AK 99567
Current Property owner(s) LINDA EVANS Day phone 907-360-6691
Mailing address 18 920 SPRUCE CREST DRIVE, CHUGIAK, AK 99567
Real Estate Agent NICHOLE PERRY W/ KELLER WILLIAMS Day phone 865-6557
2. TYPE OF DWELLING:
Z Single Family (w/wo ADU)
Fj Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: .3
4. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage ❑
Community Class Well E]
Public Water System 0
TYPE OF WASTEWATER DISPOSAL:
Individual
Holding.Tank
❑
Community
❑
Public Sewer
❑
WaiverNariance request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ No Waiver Fee $
Date of Payment 90 qC) Date* of Payment
Receipt Number 0 ol, Q �� (o b Receipt Number
COSA # Q 5 C 96 tbuWaiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179
Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507
Engineer's Printed Name: Jeffrey A. Garness Date: 2lZf�Z�
In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system o�OF
in accordance with the guidelines and regulations established by the Municipality of Anchorage and ��,.• "' / 4
industry practices. The reported results describe the condition of the system/s on the date/s of the O P,• `9500
evaluation. Separation distances were measured to readily identifiable features. Hidden defects or
encroachments may exist that were not identified during the evaluation. The operational life of all wells ° 49—
and
9 and septic systems depend upon a variety of variables, including but not limited to, soil conditions, • ' ' • ' • ' • • . • • • • • • • • • • . • . .
groundwater levels (that may fluctuate during the year), quality of construction (materials and
workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and ....
are outside the control of GEG. Satisfactory test results do not guarantee future performance of the Q eff G rness:
system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of 009 CE -7953
the well or septic system. GEG makes no representation whether an alternative well or septic system s c G
can be installed on the property in the event either of the current systems fail to perform adequately in
the future. The content of this report is for the sole benefit of the person/party that retained GEG to dprofessionoo�
perform the evaluation. Reliance upon the information provided in this report by any other person or ��OOD0000
party (including subsequent property purchasers) is not authorized, nor will it confer any legal right
whatsoever.�c,1PALIr)' jtp884
6. DSD SIGNATURE
System #1 Approved for bedrooms,, '� v
System #2 Approved for bedroomsnz
^`
Disapproved1
Conditional approval for bedrooms, with the following ,40t�t
wl-
S Otil g L,
By: Original Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
AO
COSA Checklist _ Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet_10.10-12.doc
COSA Checklist
Legal Description: TI 5N, R1 W, SECTION 19; LOT 23
If more than 1 septic system on lot: COSA Checklist # 1 of 1
A. WELL DATA
0 Well log is filed with Onsite (or attached)
Date drilled 7120/73
Total depth 111 ft
Cased to 81 ft
❑■ Sanitary seal is functioning correctly
0 Wires are properly protected
Casing height (above ground) 12+- in.
Date of flow test for COSA 2/19/20
Static water level at beginning of test *44.0 ft
Comments *ON 12/26/2019
B. TANK DATA
Age of tank(s) 47 years
Tank type/material SEPTIC/STEEL
Measured operating fluid level in septic tank
0 Standpipes/foundation cleanout per record drawing
Date of pumping 'TANK TO BE REPLACE IN SPRING OF 2020
D. ABSORPTION FIELD DATA SEEPAGE PIT
Which system tested (date installed) 7/73
0 ALL standpipes present per record drawing
Total measured depth from grade 8.9 ft (max)
Measured depth to pipe invert from grade 4.3 ft (min)
❑ N/A — pressurized field
Q Monitor tubes go to bottom of effective. If not, state
depth into effective
❑■ Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced N/A gallons
Comments/Deficiencies: 'SEE HOMEOWNER QUESTIONAIRE
COSA Checklist yellow sheet
Parcel ID: 051-241-00
Structure served by this system 1
Well production at time of test 2.1 gpm
Water storage tank volume 400 gallons
Well disinfected for coliform test? ❑ Yes IN No
9 Coliform bacteria is Negative
Nitrate mg/L ■❑ Nitrate less than MRL (ND)
Arsenic 12.0 ug/L ❑ Arsenic less than MRL (ND)
Collected by GEG, LTD.
Date of Sample 12/27/19 & 1/3/20
C. LIFT STATION
❑ Required maintenance completed
Age of lift station years
Lift station material
Comments: N/A
Adequacy test date 12'26119
Results Q✓ Pass For 3 bedrooms
Fluid depth prior to test 6 in
Water added 536 gal
New depth 7 in
Elapsed time 120 min
Final fluid depth 4 Ir4rA
Absorption rate 4�� gpd
Any rejuvenation treatment (past 12 months) *UNK
If yes, enter date N/A
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
E] Yes
*68Community
Sewer Manhole/Cleanout > 100'
❑ Yes
if No
ft
0 Yes
if No ft
Neighboring Tank > 100' 0 Yes
if No
ft
Private Sewer/Septic Line > 25'2] Yes
if No ft
Absorption Field on Lot > 100' ❑ Yes
if No
**95 ft
Holding Tank > 100' ❑✓ Yes
if No ft
Neighboring Absorption Fields > 100'
Animal Containment > 50' Q✓ Yes
if No ft
El Yes
if No
ft
Manure/Animal Excreta Storage > 100'
—❑✓
Community Sewer Main > 75' Q✓ Yes
if No
ft
Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
***5+
Building Foundations > 10' [J Yes if No ft Surface Water > 100' 0 Yes if No ft
Property Line > 5'
E] Yes
if No
ft
Wells on Adjacent Lots:
Absorption Field > 5'
El Yes
if No
ft
Private Wells > 100' Yes if No ft
Water Main > 10'
0 Yes
if No
ft
Community Wells > 200'✓❑ Yes if No ft
Water Service Line > 10'
El Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10' Yes if No ft If absorption field is under driveway comment below
Property Line > 10' Yes if No ft Wells on Adjacent Lots:
Water Main > 10' Q Yes if No ft Private Wells > 100' Yes if No ft
Water Service Line > 10' Q Yes if No ft Community Wells > 200' Q Yes if No ft
Surface Water > 100' Q Yes if No ft
F. ENGINEER'S COMMENTS
*TANK INSTALLED 7/1973. MET SEPARATION DISTANCE AT TIME OF INSTALLATION
**WAIVER GRANTED (SEE WR #101051). ***MET SEPARATION DISTANCE AT TIME OF INSTALLATION.
NO FOUNDATION CLEAN-OUT (SEE MAY 2010 COSA).
G. ENGINEER'S CERTIFICATION 00006oO X00
I certify that 1 have determined through field inspections and review O
of Municipal records that the above systems are in conformance with Opp T
MOA COSA guidelines in effect on this date. , , , ,, , , , , f , ,,,,,,,, , , , , , , , , , • ,�
0•' 1. ...... ...........
QO effr A. Gar ess:'
Q 9,• C 795• �4 �q 4
4 ire •• .....• ��°p
COSA Checklist yellow sheet 4� a Pro f e ssxor°oma
#AECC884
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT i 907-343-7904
On -Site water and wastewater Section s Fax: 343-7997
WWW.MLini.org/onsite
Arsenic Advisory
Certificate of On -Site Systems Approval # OSC2O1O67
Subdivision: T15N R1W Sec.19 Lot 23
A water sample revealed an arsenic concentration of 12 micrograms per liter
(ug/L). The Environmental Protection Agency (EPA) has established a maximum
contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While
private wells are not subject to this regulation, EPA standards are based on existing
health information and can therefore be used to gauge the relative quality of water
from private wells. Information on arsenic is available from the On -Site Water and
Wastewater Program website (www.muni.org/onsite) or at 343-7904.
This advisory must be attached to all copies of the subject Certificate of On -Site
Systems Approval.
Mailing Address P O Box 196650 * Anc�iorage, Alaska 99519 6650 7 www muni org
S
ENGINEERING oSALES- CONSULTING
March 4, 2020
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Ref: Conditional COSA Request for TI 5N R1 W Sec19; Lot 23
To whom it may concern:
The subject property needs a tank replacement and a permit was approved on 2/14/20.
The previously mentioned work is to be completed in spring/summer of 2020. We are unaware
of any environmental or health risks associated with delaying the tank install until the
spring/summer of 2020. Attached with the COSA were quotes for the proposed work as well as
the required escrow letter.
If you have any-lquestions, please contact us at 337-6179. Thank you for your assistance.
(
Sincerelv. P ! I
P. E., M.S.
3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
RESIDENTIAL
MnRTGAC�F I I C
NMLS #167729
100 Calais Drive
Anchorage, Alaska 99503-4049
(907) 222-8800 phone
(907) 222-8801 fax
1-888-357-2707 toll free
www.residentialmtg.com
March 5, 2020
Municipality of Anchorage
On-site Water and Wasterwater Progam
PO Box 196550
Anchorage, AK 99519-6650
Re: Permit #OSC201067 Well/Septic
Parcel #05124102000
To Whom It May Concern:
Residential Mortgagage will be holding an escrow in the amount of $11,400 to ensure
completion of the installation of a new septic tank and the raising of monitoring tubes.
Attached please find a copy of the estimate and scope of work from Red Dog Masony, Inc.
Residental Mortgage will not release any escrow funds without written approval from the MOA.
Please call me if you have any questions,
Denise J. Long
Sr. Vice President
(907)222-8812 ph
longd@residentialmtg.com
1