HomeMy WebLinkAboutMCMAHON BLK 3 LT 15McMahon Block 3 Lot 15 #017-042-15 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL iNSPECTION REPORT Permit Number: 0SP101079 PID Number: 017-042-15 Name: Merit Homes, Inc. Wastewater System: [] New [] Upgrade Address: P.O. Box 111982 Anchorage, AK 99511 ABSORPTION FIELD Phone: Number of Bedrooms: 334-9233 4 [~ Deep Trench [] Shallow Trench FI Bed [] Mound [] Other: LEGAL DESCRIPTION Soil Rating: Total Depth f .... dgina, grade: 1.2 GPD/Ft2 11.0 Ft. Block: 3 Lot: 15 Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: McMahon 3.0 Ft. 8.0 Ft. Township: Range: Section: Fill added above original grade: Gravel Length: 1-2.5 Ft. 34 Ft. Well: [] New [] Upgrade Gravel width: Number of lines: Distance between lines: 3 Ft. 1 - Ft. Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material: Private 85 Ft. 85 Ft. 544 Ft2 ASTM D3034 PVC Ddiler: Date Ddlled: Static Water Level: Installer: Date installed: Alpine Drilling 10/02/2010 74 Ft. Red Dog Excavating 6/19-22/2010 Yield: 7 GPM Pump Set at:61 Ft. Casing HeightAboveGround:>l.5 Ft. TANK SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other: T~ To Septic Absorption Lift Holding ~ub]ic/Private Manufacturer: Capacity: From~ Tank Field Station Tank Sewer Line Anchorage Tank 1,250 Gal. Material: Number of Compar[ments: Well >100' > 100' N/A N/A >25' Steel Two surface water >100' >100' N/A N/A ~ ,/ LIFT STATION Size: Manufacturer: Lot Line >5' >10' N/A N/A Ga[, "Pump on" level at: "Pump off" level at: in. High water alarm at: Foundation >5' > 10' N/A N/A in. in. cudain Drain None Noted Pump Make & Model = Electrical Inspections performed by: Remarks: BENCH MARK Location and Description: Garage Slab Assumed Elevation: 100.00 Ft. Inspections performed by: A-Harala Dates: 1st 6/20/2010 2nd 6/21/2010 ,~ ,x,,,¥.o It .'~.L~,.~'~ ~' (,9: Development Services Department Approval ~ · Conditional Approval Date: ~.~tj.~_.~.,.~. i ..~LV~.._~t..~.m-.--~....'~.~',~,~ ',~'~.~...~...o..- -..,,,,-- Permit Number: OSP101079 Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 Page 2 of 3 PID No. 017-042-15 FURROW CREEK ROAD 163.28" WELL A.C. DRNE / / Alternate Site LEGEND: C - Cleanout S - Septic Vent TH - Test Hole M - Monitor Tube EXISTING BUILDiNg// PLAT NO. 65-86 McMAHON SUBDIVISION LOT 15, BLOCK 3 30,940 S.F. S2 I 8.5' C4 12.4' C5 [ 44.9' M 1 40.2' ~TH3M1 · ~C5 B 20,6' 28.8' 37.3' 71.2' 67.0' Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP101079 Page 3 of 3 PID No. 017-042-15 94.58 / / 94.4 · · 99.7 Finished Grade Existing Grade 79.5 NO Groundwater 6/26/10 97.5 Geotextile Fabric Drainfield Rock 34' (Trench Length) 99.8 86.3 --~ 94.4 PROFILE AS-BUILT No Scale $- 6- 8- @- 19- 20- Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.ci.anchoraqe.ak, us (907) 343-7904 Soils Log - Percolation Test Slope Site WAS GROUND WATER ~,/ ENCOUNTERED? S IF YES, AT WHAT DEPTH? ~" L O Depth to Water After Monitoring? ',~` ~ PERCOLATION RATE ~ (minutes/inch) PERC HOLE DIAMETER / ,1 TEST RUN BETWEEN ~, I~'i; ,~'-~'~' FT COMMENTS ,~et'~ ¢~V~ly W~ ¢r~.¢K~L Reading Date Gross Time Net' Time Depth to Water Net Drop PERFORMED BY: v,,¢~ I '~-'~,~-.~-t~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~ O ~ Z,?-~ · FRC~ r~oya~ ~menors ~u fL~;bAM ! :~lpine Drillin9 FRX NO. :90? 345 02[a2 0c'c. 26 2818 139:09RP1 Alpine Drilling & Enterprises ~orehole Data: Soil Type, Thickness & Water Strata Well Log Permit Number: #$V~OSPfOf~02 Date of Issue: 7-9-f0 Parcel Identification Number.' ~ Date Started: 10-2-fO Date Completed: 10-2-1...0 Is welt located at approvec[ permit location? · Yes Legal Description: McMahon BIk 3 Lt 15 G:2835 Property Owner Name & Address: Merit Homes LLC · ~ Box 'f 11982 Ant, boracic, Alast~a 995 7'~ Depth (fi) Method of Drilling x air rotary [] oabte tool ]=rom To Casing type: 0 2 Wall Thickness'..£5._.__.~0 inches Diameter: ~ inches O~: ~ f~ 2 4 Liner Tfpe: ~ ~ ~ ~ Di~e~: ~ inches ~: ii ]~ Casing s~p a~ve gromnd: /d 8~ S~fic water l~el (~m ~o~d 83 85 ~umping l~l: ~ fe~ ~ ~ hours pump~g ~ ~m R~ve~ ~te: ~ ~m Me. od of T~ng: air ~[~ . · Well Inm~ Opening x O~n ~d ~ Op~ Hole 6~ut ~pe: bent~lte De~: S~ 0 f~ Pump: In.he ~p~ .... Pump si~ ~p B~d N~ W~ll Dtsinf~ Upon Comgl~on? x Y~ M~tho~ of~s~fioa: cMorine table~ Cammen~: PO Box 110~96 ~nchorage ~K 995'11 Volume: I bg gtopped,,? fe~t Mark Begich Mayor Development Services Deportment Building Safety Division On-Site Water & Wastewater Program 4700 Elmor¢ Street PoO. Box 196650 Anchorage, AK 99519-6650 www.muni.orq/onsit¢ (907) 343-7904 Pump Installation Log Well Drilling Permit Number: SWOSPlOi079 Date of Issue: 10/9/2010 Parcel Identification Number: OI 7-042-15 Replacement Only: YES NO Legal Description Lot 15, Block 3 McMahon Property Owner Name & Address: Merit Homes Pump Installation Date: 10/9/2010 Pump Intake Depth Below Top of Well Casing: 61 feet Pump Manufacturer's Name: Goulds Pump Model: 10 GPM Pump Size 1/2 hp Pitless Adapter Burial Depth: 13 feet Pitless Adapter Manufacturer's Name: Campbell Pitless Adapter Installer: Red Dog Well Disinfected Upon Completion? [] Yes [] No Method of Disinfection: Recirc Comments: Pump Installer Name: Aarow Pump & Well Service LLC PO Box l10496,Anchorage, AK. 99511 (907) 346- 9355 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. Permit Number: Tax Code Number: Work Type: On-Site Water & Wastewater System Permit OSP101079 01704215000 WelISeptic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Initial Permit Effective Dates: June 17, 2010 to June 17, 2011 Design Engineer: ANDERSON ENGINEERING Subdivision: MCMAHON Site LegalAddress: MCMAHON BLK 3 LT 15 G:2835 Owner/Address: MATTSON DAN R LIVING TRUST MATTSON DAN R/TRUSTEE PO BOX 112174 ANCHORAGE AK 995112174 Site Mailing Address: 3900 Furrow Creek RD, Anchorage Lot Size In Sq Ft: Total Bedrooms: 30940 4 This permit Is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either. A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: ~, ~, -ZI '/~' Date: Municipality of Anchorage Development Services Department Building Safer7 Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.orglonsite (907) 343-7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR a SINGLE FAMILY DWELLING o~OlOIOT-~ Parcel I.D, 017-042-15 Property owner(s). Medt Homes, Inc. Mailing address P.O. Box 111982 Anchorage, AK Site address Furrow Creek Road .Day phone 334.9233 Zip Code 99511 .Zip Code 99516 Legal description (Sub'd., Block & Lot) McMahon Subdivision, Block 3, Lot 15 Legal description (Township, Range & Section) Lot Size 30,940 Sq. Ft. Number of Bedrooms Four (4) THIS APPLICATION IS FOR (~;~ all that apply): THIS APPLICATION IS AN: Absorption Field [] Initial Septic Tank [] Upgrade Holding Tank [] Renewal P~vy [] Private Well [] Water Storage [] [] [] [] I certify that the above Information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes, (Signature of property owner or authorized agent) Waiver Fees: Date of Payment: Receipt Number:. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) June 10,2010 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 15, Block 3, McMahon Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 15, Block 3, McMahon Subdivision intends to construct a new four- bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the existing wells and septic systems on surrounding lots. No conflicts exist between the proposed well and septic system and wells or septic systems on adjacent lots. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes recently placed on the lot in the area of the absorption trench and alternate site indicate silty gravel and sand (GM/SM). The percolation rate of the soil was determined to be 4 minutes per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring Period. An application rate of 1.2 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,250-gallon septic tank and a new 32' long by 3' wide by 8' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 3.0' below the surface and the total depth will be 11.0'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the septic system slopes to the north at approximately 5%. The new trench will be constructed parallel with the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. Lot t5, Block 3, McMahon Subdivision June 10, 2010 Page Two If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. o The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments 17 //,~6 VACANT 25 ",:] 6 .. 7 24 AREA MAP SCALE /,' = 100' McMAHON SUBDIVISION LOT 15, BLOCK 3 30,940 S.F, FURROw CREEK ROAD PractiSed I I SITE PLAN SCALE 1' = 30' LOT 15, BLOCK 3, MCMAHON SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home Deep Trench System Perc. Rate: 34 Min./Inch 1,250 GaIIon Septic Tank Application Rate: 1.2 GPDISF 8' Drainfield Rock 4 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 500 SF Absorption Area 500 SF/16 SF/LF = :31.25 LF Trench Length THEREFORE: Construct a :32' Long x :3' Wide x 8' Effective Depth Absorption Trench at the Location Shown. Flow Line Elevation in Trench to be 3.0' Below Original Ground Surface. Total Depth to be 11' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Maintain 100' Separation from WeIIs in the Area. Natural Backfill Geotextile -- Fabdc Perforated PVC (Holes Down) DrainfieldRock TYPICAL DEEP TRENCH SECTION (NO SC^LED ......... NOTE: Grade Area Over Trench to Drain Away. ,' ~.."" z~,, M~n~mum 6 Separation From Bedrock. Minimum 4' Separation From Groundwater. ,,.?...~.~~ Minimum 100' Separation From Wells in the Area. ~'~ Minimum 100' Separation From SurfaceWateror Streams.' ~.~-... No. c~-,,~. ~700 DEPTtl (f~t) 1 2 3 4 $ 8 9-- 11 20 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT BRAGAW STREET ANCHORAGE, AK, 9c)51g-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: PERFORMED FOR: DATE: 5/10/2010 PARCEL ID#: LOT 15t BLOCK 3r MCMAHON SUBDIVISION MFRIT PROJECT No.: TECHNICIAN: ItEst,o . . I OB/OG SILTY GRAVEL SAND GM/SM BOH @ 18' A. HARALA SLOPE NO $1T[~ PlAN SEE SITE pL,a,N READING GI~OSS TIM, El NET TIMEI DEPTHwATERTO NET DROP (INCHES) tN NUTES) J(MINUTES) J (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 2 14:42/14:52 14:42/14:52 14:42/14:52 14:42/14:52 10 I0 10 10 5.88/8.19 5.63/8.06 5.56?7.88 5.50F/.94 2.31" 2.44" 2.31" 2.44" 3 4 5 14:42/14:52 10 5.63/8.12 2.50" 6 14:42/14:52 10 5.56/8.06 2.50" PERCOLATION RATE; 4.0 (Mnq/mCH) PERC. HOLE DIA, 6" cnqCHES) TEST RUN BETWEEN: 5.0 FT. and 6.0 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. !, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE.'. 6/10/2010 /~700 DEPTII (feet) 1 2 3 4 $-- 6 7 8-- 9-- 11 20 IvlUNICIPALITY OF ,ANCHORAGE DEVELOPP1ENT SERVICES DEPARTHENT BRAGAW STREET ,ANCHORAGE, ,AK 9c)51c)-0050 SOILS LOG - PERCOLATION TEST ] LEGAL DESCRIPTION: PERFORMED FOR: DATE: 5/10/2010 PARCEL ID#: LOT 15~ BLOCK ..3~ MCMAHON SUBDIVISION MERIT HOMES PROJECT No.: TECI~qlCIAN: A. HARALA I TEST.OLE2 I OB/OG SILTY (;RAVEL SAND GM/SM BOH @ 18' SLOPE WAS GROUteD WATER £NCOUNTEREI~' NO PLAN SEE SITE DATE REAmNG G~OSS T~.E ~ET T~M,~ ~[~.~o NeT DRQP [HINUTES) I",HINUTES) I (INCHES) ] [INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 5/21 I 18:12 9.44" 2 18:42 30 13.81" 4.38" 3 18:45 9.50" 4 19:15 30 14.12" 4.63" 5 19:16 9.38" 6 19:46 30 , 14.06" 4.69" PERCOLATION RATE; 6.5 (MINflNCtl) PERC. HOLE DIA, 6" TEST RUN BETWEEN: 5.5 FT. and 6.5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT TI'IlS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE.'. 6/10/2010 Parcel I.D. 017-042-15 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www. muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING COSA# Expiration Date: GENERAL INFORMATION Complete legal description Lot 15, Block 3, McMahon Subdivision Location (site address) 3900 Furrow Creek Road Anchorage, AK 99516 Current Property owner(s) Merit Homes, Inc. Mailing address P.O. Box 111982 Anchorage, AK 99511 Day phone 334-9233 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA will be held by DSD for pickup. NUMBER OF BEDROOMS: Four (4) TYPE OF WATER SUPPLY: Individual Well [] Individual Water Storage [] · Community Class ~ Well [] Public Water System [] TYPE OF WASTEWATER DISPOSAL: Individual On-site [] Individual Holding Tank [] Community On-site [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation. based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal end,rathe codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering . Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. bedrooms. DSD SIGNATURE ~.-~'J Approved for L~ Disapproved. Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory (Rev 11105) Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: A. WELL DATA Well type Private Date completed 10/2/10 Total depth 85 f. Date of test Static water level Well production WATER SAMPLE RESULTS: Lot 15, Block 3, McMahon Subdivision Parcel ID: 017-042-15 If A, B, or C provide PWSID # Sanitary seal (Y/N) Y Cased to FROM WELL LOG 10/2/10 74 7 Coliform 0 cOloniesll00 mL Arsenic: N/D ug/I B. SEPTIC/HOLDING TANK DATA 85 ff. g.p.m. Nitrate 2.36 rhg/L Date of sample: 10/19/10 Well Log (Y/N) Y Wires properly protected (Y/N) Y Casing height (above ground) >18 ' in. AT INSPECTION g.p.m. Tank Type/Material Septic/Steel Tank size 1,250 gal. Foundation cleanout (Y/N) Y Date of pumping New Const. ABSORPTION FIELD DATA Date installed 6/21/2010 Length 34 ff. Total depth 13.5 ft. Number of Compartments Two Depression over tank (Y/N) Pumper Soil rating (g.p.d.l~ or ft2/bdrm) 1.2 GPD/SF Width 3 ff. Eft. absorption area, 544 ft2 Monitoring tube Date of adequacy test New Const. Results (Pass/Fail) Fluid depth in absorption field before test in. Elapsed Time: ~ min. Final fluid depth Any rejuvenation treatment (past 12 mo.) (YIN & type) Other bacteria 0 colonies/100 mL Collected by: A. Harala Date installed 6/20/2010 Cleanouts (Y/N) Y High water alarm (Y/N) N System type Deep Trench Gravel below pipe 8 ft. Y Depression over field N For bedrooms Water added .......... gal. New depth in. in. Absorption rate >= g.p.d. · N If yes, give date D. LIFT STATION Date installed "Pump on" level at ~ in. Datum E. SEPARATION DISTANCES SEPARATION DISTANCES FROM VVELL ON LOT TO: Fe Septic tank/lift station on lot >100' Absorption field on lot >100' Public sewer main N/A Sewer/septic service line >25' Animal containment areas >50' Size in gallons "Pump off" level at Cycles tested in. Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? in. On adjacent lots >1oo' On adjacent lots >1oo' Public sewer manhole/cleanout Holding tank N/A Manure/animal excrete storage areas N/A >100' SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line >5' Water main N/A Water service line >10' Wells on adjacent lOts >100' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line >1o' Building foundation >1o' Water Service line >1o' Curtain drain None Noted >100' COMMENTS: Absorption field >5' Surface water >100' Water main >10' Driveway, parking/vehicle storage >25' Surface water >1oo' Wells on adjacent lots G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engfneer's Printed Name Michael E. Anderson, P.E. Oate 10/26/2010 COSA Fee $ Oate of Payment Receipt Numb~,,- ~_ (Rev, 1WOS) % io- ,27- /o Waiver Fee $ Date of Payment Receipt Number SGS Ref.# 1105636001 Client Name Anderson Engineering Printed Date/Time 10/22/2010 14:07 Pro. iectName/# McMahon S/D , L15,B3 Collected Date/Time 10/19/2010 10:21 Client Sample ID Private Well From Crawl Space Received Date/Time 10/19/2010 12:00 Matrix Drinking Water Technical Director Stel~hen C. Ede Saml31e Remarks: Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date Init Metals by ICP/MS Arsenic ND 5.00 ug/L EP200.8 C (<10) 10/19/10 10/21/10 NRB Waters Department Total Nitrate/Nitrite-N 2.36 0.100 mg/L SM20 4500NO3-F B (<10) 10/20/10 AYC Microbiology Laboratory E. Coli Negative 1 100mL SM20 9223B A 10/19/10 DLC Total Coliform Negative I 100mL SM20 9223B A 10/19/10 DLC PLAT NO. 65-86 McMAHON SUBDIVISION LOT 15, BLOCK 3 30,940 S.F. FURROW CREEK ROAD WELL S 86o40,11,,E 163.28' ~ ~C. DRIVE CONC. WALK ~ 20.0' EXISTINO BUILDINO Z 0 0 54.0' 52'0' 55.5' SEPTIC STSTEM 10' UTIL. ESMT. S 88°05'00-E 165.09' 1"=20' SURVEY lNG, LLC IT IS THE RESPONSlBIETY OF THE OWNER TO JEFF A. GASTALDI, R.I-S. DETERMINE THE EXISTENCE OF ANY EASEMENTS, 2000 E. DOWUNG RD., SUITE 8 COVENANTS OR RESTRICTIONS WHICH DO NOT ANCHORAGE, ALASKA 99507 APPEAR ON THE RECORDED SUBDIVISION PLAT. PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA GRID DATE HEREON BE USED FOR CONSTRUCTION OR FOR ESTABUSHING BOUNDARY OR FENCE UNES. 2855 10/25/2010 ANCHORAGE RECORDING DISTRICT, ALASKA F.B. JOB NOG NOTE: NO CORNERS SET THIS DATE. 10-08 MS155