Loading...
HomeMy WebLinkAboutPARK PLACE LT 8APa k Plac Lot 8A #020-092-95 On-Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP101081 Tax Code Number: 02009295000 Work Type: WellSeptic Initial Permit Effective Dates: June 25, 2010 to June 25, 2011 Design Engineer: GAF{NESS ENGINEERING GROUP LTD Subdivision: PARK PLACE Site LegalAddress: PARK PLACE LT 8A G:3337 Owner/Address: GAY MATT E & SANTINA M PO BOX 100693 ANCHORAGE AK 995100693 Site Mailing Address: 16430 Saint James CIR, Anchorage Lot Size in Sq Ft: 43599 Total Bedrooms: 4 D'e pa r tmen ~ This permit is for the construction of: Y Disposal Field Y SepticTank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Date: Date: Municipality of Anchorage P.O. Box 196650 ® 4700 Elmore Road Anchorage, Alaska 995t9-6650 ® (907) 343-7904 ® Fax (907) 343-7997 http:llwww.muni.or.qlOnsite Development Services Department On-Site Water and Wastewater Program · Department **** VARIANCE/WAIVER REVIEW **** WR#: OSP111100 HA#: PID#: 020-092-95 Legal Description: Park Place, Lot 8A Engineer: GEG Permit/C: OSP101081 Applicant: Matt Gay Your request for a waiver of the required 100 feet horizontal separation from the absorption field to the surface water has been approved. The approved separation distance is 80.0 feet. This waiver approval applies to the existing absorption field to surface water separation only. Any furore upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department._ Waiver is Granted: X Waiver is not Granted: Date: 6/10/2011 Approved by',~.~ ?' J Name of Reviewer llllllllllllllll I I I llllllllllll I Illlll I lll I I I ll~ll~ffi Illllll lll ill i lllll i llllll i lllll iI Rec#: 001695 Amount: $800.00 Date Paid: 6/10/2011 **** VARIANCE/WAIVER REVIEW **** Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 0N-SITE SEWER/WELL PERHIT APPLICATION FOR A SINGLE FAMILY DWELLING Property owner(s) MATT GAY Day phone 727-5957 Mailing address 16450 SAINT JAMES CIRCLE *ANCHORAGE, AK Site address Zip Code 99516 Legal description (Sub'd, Block & Lot ) PARK PLACE LOT 8A Legal description (Township, Section & Range) N/A Lot Size Sq. Ft. Number of Bedrooms 4 THIS APPLICATION IS FOR ( [~all that apply): Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] THIS APPLICATION IS AN: Initial [] Upgrade [] Renewal [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. Permit/Rush Fees'~ Date of Payment: Receipt Number: (Rev. 11/05) ~Waiver Fees: Date of Payment: Receipt Number: GARNESS ENGINEERING GROUP, CONSULTANTS & GENERAL CONTRACTORS Ltd. June 10,2010 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 Elmore Rd. P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Proposed Initial Septic for Park Place; Lot 8A, To whom it may concern: The subject lot is currently vacant and the homeowner is proposing to construct a 4 bedroom house on it. We are proposing to drill a private well and install a septic system serve the proposed residence. We are proposing to install a 1250 gallon septic tank and a deep trench type drainfield. Two test holes were excavated on the property. The drainfield will be designed around the 30 foot radius of test hole #2. Comments regarding the design are summarized as follows: 1. SOILS: See the attached soil logs which show the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system. 4. TOPOGRAPHY: As can be seen on the attached design drawing the average topography below the drainfield is 5-15%. 5. WAIVER REQUIREMENT FOR SAND FILTER: We are requesting to use the native material classified as sand as the sand filter for the deep trench type drainfield. We are unaware.,of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any,~luestions, please contact us at 337-6179. Thank you for your assistance. x'-J'e~4y k ..[~rnes¥, P.E., M.S. Pres~en ~J NOTE: Attached is a site plan drawing, a design drawing, one soil log, which are all part of the design package for this septic system. (Contact G.E. G. Ltd. for 7page construction spec~cation letter.) 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com GARNESS ENGINEERING G. ROUE Ltd. CONSULTANTS & GENERAL CONTRACTORS June 9, 2011 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 Elmore Rd. P.O. Box 196650, Anchorage, Ak 9951%6650 (907) 343-7904 O ell loo Ref: Design Revisions for Park Place; Lot 8A, (Permit #OSP101081) To whom it may concern: We are proposing to make the following revision to the aforementioned design: 1. DRAINFIELD EFFECTIVE: The drainfield has been revised and we are propsing to have 7.5' of effective in the dual trenches rather then 6.5'. This is to shorten the drainfields length so that we can maximize our separation distance from the surface water to the south. 2. SURFACE WATER WAIVER: We are requesting an 80 feet waiver from the proposed drainfields to the nearest surface water. Justifications for this waiver are: · The surface water is located to the south of the drainfields and the natural topography of the lot runs east to west. If the drainfields were to daylight out, wastewater would not flow towards the surface water. See the attached topography drawing. · The path of travel of any potential daylighting wastewater would be over 100 feet before it reached the surface water. If this is not the case, during the septic installation, berms will be constructed to insure that the path will be 100 feet or greater. · Drainfields shall be laid out and constructed in such a fashion as to provide the maximum distance possible from the surface water to the drainfield. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any quesgq?ns, please contact us at 337-6179. Thank you for your assistance. Presi~j:~ ~ , 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com GARNESS ENGINEERING GROUE Ltd. CONSULTANTS ,& GENERAL CONTRACTORS June 14, 2011 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 Elmore Rd. P~O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Lot Line Waiver Request for Park Place Lot 8A, To whom it may concern: We request that your department issue a 7-foot lot line waiver from the east property line to the proposed drainfield. The proposed drainfield on Lot 8A will have a separation distance of greater than 30 feet from the neighboring septic system on Lot 7 (Park Place S/D). We are unaware of any adverse impactsq;his waiver would have on adjacent wells or septic systems. If you have any questions, please cdn[act us at 337-6179. Thank you for your assistance. President )/ fiess,~.~., U.S. 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com \ iI \ I/ ~O0~LL~IUS~ \ / '.?/.' ../~'",./~~ --. I _ X~ 100' WELL ~IUSl / 5~1~~ / ''~ PARK P~CE LOT gA I ] // ~ ~ ~ -- --- ' / '. -- RANSOM RIDGE LOT 8 I ,,, . GARNESS ENGINEERING, G:RO'UP, PREPARED FOR: PHONE NUMBER: PA~E NUMBER: LEGAL DESCRiPTiON: DRAWN BY: ~'Q~, '~: $~/95~/ .,' ~1 SITE PLAN 6/9/11 DESIGN CRITERIA: NUMBER OF BEDROOMS: 4 GALLONS PER DAY (GPD): 600+ PERCOLATION RATE/S: 8.5 PROPOSED APPLICATION RATE: O,B MINIMUM DRAINFIELD SQ,FT.: 750 DRAINFIELD DESIGN: MAXIMUM DEPTH: 10.5 FEET MAX WIDTH: 2,5 FEET LENGTH: 58 FEET (2 @ 29 FEET) M.O.A. APPROVED SAND FILTER: N/A EFFECTIVE: 6.5 FEET REDUCTION FACTOR: N/A ACTUAL SQ.FT.: 750 GEG, Ltd. HAS A 7 PAGE SPECIFICATION LETTER THAT PERTAINS TO THIS DESIGN. TO OBTAIN A COPY OF THE LETTER CONTACT GEG. BY PROCEEDING FORWARD WITH THIS INSTALLATION, THE ENGINEER, WELL DRILLER, CONTRACTOR AND PROPERTY OWNER AGREE THAT THEY HAVE READ THESE SPECIFICATIONS AND AGREE TO ACCEPT THE TERMS AND CONDITIONS OUTLINED. ALTERNATE DESIGN CRITERIA: NUMBER OF BEDROOMS: 4 GALLONS PER DAY (GPD): 600+ PERCOLATION RATE/S: 8.5 PROPOSED APPLICATION RATE: 5.0 MINIMUM DRAINFIELD SQ.FT.: 120 DRAtNFIELD DESIGN: MAXIMUM DEPTH: 10.5 FEET MAX WIDTH: 2.5 FEET LENGTH: 10 FEET M.O.A. APPROVED SAND FILTER: N/A EFFECTIVE: 6.5 FEET REDUCTION FACTOR: N/A ACTUAL SO.FT.: 150 SCALE: 1"= 50' / /// REV SED / / / INSTALL FCO -~ · .. ~i ..' ,:..=..,.:..,:..: PROPOSED GARAGE PROPOSED GALLON STEP TANK. RESERVE SITE WILL ~/--~ REQUIRE AN ADVANCED TREATMENT SYSTEM. TH#1 MT NOTE: THE CONTRACTOR PROPOSED 4 BEDROOM HOUSE CO PROPOSl DRAINFIELDS SHALL HAVE THE EAST LOT LINE, AND ALL WELL RADII FLAGGED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION. CO 2 GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENI=F~AL CONTRACTORS F.. ~IDOR ROAD, SUITE 101 * ANCHORAGE, AK 99.507 * PHONE (907)337-6179 * FAX (907)33B-3246 * WEBSffE: www.gorne~engineefirlg.com PREPARED FOR: IPHONE NUMBER: MATT GAY I 727-59.37 LEGAL DESCRIPTION: PARK PLACE LOT 8A PAGE NUMBER: 20F3 IDRAWN BY: DATE: P.N.B 6/14/11 TYPE OF WORK: SEPTIC DESIGN DRAWING x / ~ i ~ X / X ~k~CE ' / --. ~ RANSO~ RIDOE LOT I ] I 100' WELL ~DIUS~I ~ 1"= 100' MATT GAY 727-5937 3 OF 3 i ~qft LEGAL DESCRPTO. D~WN BY: VO~.) ~'. ~CE~79~5 .. TOPOGRAPHICAL DRAWING 6/10/2010 CONSULTANTS & GENERAL CONTRACTORS LEGAL DESCRIPTION: PARK PLACE; LOT 8A%(/^ ¢ 'd t,~'r~,~,¢~..',.,/? ~'E_L~955 o..' ~/ PERFORMED FOR: MATTHEW GAY DATE: 8/6/08 (feet) ~-'. ORGANICS [TEST HOLE #2I 1 Iii / fl I SOIL CLASSIFICATIONS I I I: · 5oo°°%°%°oo%o0 ~ GM CL '-¢ / / \\ °°%°°°° .GC OL TH#1-~ \ 00%0%0 ~ SP CH 0%0~0~c ~ ~/~ I / ~-VACANT-~ / 5--00%0%0~ SM OH/ j/I ', / o°o o°o°c I, 00%0°0° SW SC TH#2 6-- 00%0%0 , °,0°%,, I I \ °~%~°~ ! .. .~ , r 0% o°o°~ DEPTH TO DATE / ./? L.oO,~,"~ 7 --ioo %~Oo~ G ROUNDWAT ER PLACE LOT 7 ;'% 0%° ~ DRY 8/6/2008 8 "' '"" 16.5' 8/1.~/2008 .... I' ...................... T ...................... ,°%-',° ~ .......... ,, %,.,- SP iF ............. %:'--~' .... ="-~':.- ........ 'SC^Er: $~! ~! II / % 1"= 100' 10 ~' ' '"' ~ ,%o,., CLOCK NET TIME WATER LEVEL NET DROP ,°o~o.';, DATE READING 1 ~ --,ooo .~% TIME (MINUTES) READING (INCHES) ,°oO,.-%i 18/11/2008 1 4:42 - 6,, _ 12--~°°°"% 2 5:12 30 2 1/2" 3 1/2" ,%~ o~'; 3 5:12 - 6" _ ,OoOo... sw/sP 4 5:42 ~0 2 ~/2" ~ 1/2" ,~, ............... ~. 5 5:42 14 -- ~ooo ,~ %, ~¢?:;~: 0 ir '.:', %;: ,%Oo~,., ¢~'"~&~- ...... ,'; ...... ";'' "::.", 6 6:12 30 2 1/2" 3 1/2" _'272 ';~' Q :' ""::': ,OoO ,, ;, . ...... ~' 17 ?°°°e"~ : ' ; t~, >,;.,/No ¢'-,l'_~ '7o~-, 1 8 -- ~i, M:'. I I I .,:¢." · ~4,.,~-~'~'~,.~?~:B~OLATION RATE 8.5 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) '~ ........ TEST RUN BETWEEN 8.0 FT. AND 9.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: · YES [] NO SOILS LOGGED BY: SUSAN OSWALT PERCOLATION TEST PERFORMED BY: DAVID GARNESS COMMENTS: PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WA~ PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: DEPTH TO DATE GROUNDWATER DRY 8/6/2008 16.5' 8/15/2008 GARNESS ENGI'NEERING GROUP, Ltd. 3701 E TUDOR ROAD SUITE 101 * ANCHORAGE., AK 99507 * PHONE: (907)557-6179 * FAX (907)338-524-6 * WEBSWE: gornessengineerlng.com,i~',/.''''''F-~ [~f~ // l~ --~""'~ Vi) · ' SOIL LOG - PERCOLATION TEST GAL DESCRIPTION PARK PLACE' LOT 8A LE · , ,,, ''. .' ,.. ~:~ (f~t) ~¢¢¢~IOR~ANiCS TEST HOLE ¢1 UPPER BENCH ~ SOIL C~SSIFICATIONS / [oO~oOoO ~ , ~ .. ¢,...~.. ~.. ~- / / ~ ~OOO~O~OOl .:,~.;...,~:: .,.~: I I I [ I I I I 1o~o~o~ II-Ill~~m ~ ~= '~ / / I~o~o% ~o~o~ocovv ~l~l~ ' "' : ~//~ / IX lII~f~".'" ~ om ~/.'/// ~" I I/ I ~--~ IiTit~',', / // ' II~I+:f:,; :GROUNDWATER; u..~ / / / L~¢,'~ / I;lil;-A; ' : O/ / ~,~ /PARK P~CE LOT 7 liIIT:?:: 9.5 8/13/2008 , T .... , ~ $% ~ ................. ~-~-~ ............ ~ .......... 9 ~e .~ . ~ ~ ~ SCALE: ~'¢~ n*T~ D=.~l~ CLOCK R P 11 dt~t~:1~ I ............. TIME I (MINUTES) READING (INCHES) i~/~/~-e ~ ,.....-., [~+ ~ ~':-': : 8/11/2008 1 4:30 - 6" 12 ~t~:%~ ~ 2 4:51 <1 0" 6" -. · ~ ~: ...... ~,~: ..... ........... -i ~ ~' ~'"~A~-~%~O~COLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) ''~J ~~TEST RUN BETWEEN 2.S FT. AND ;.S FT. m SOILS LOGGED BY: SUSAN OSWALT PERCOLATION TEST PERFORMED BY: DAVID GARNESS COHHENTS: PERFORMED BY GEG, Ltd. 1, JEFFR~ A. GARNESS, CERTI~ THAT THIS WAS ~ERF.,ORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: ~/ / '~ DEPTH TO DATE GROUNDWATER 10.5' 8/6/2008 9.5' 8/13/2008 Crewdson, James A. From: Sent: To: Cc: Subject: Attachments: Crewdson, James A. Wednesday, June 08, 2011 4:27 PM 'Jeff Garness' Rob Campbell; 'Matt Gay '; Wockenfuss, Deborah M.; Noffsinger, Ross D. Park Place Lot 8A Crewdson, James A. (CrewdsonJA@ci.anchorage.ak.us) (CrewdsonJA@ci.anchorage.ak.us).vcf Jeff, After meeting with Rob, Matt, and Deb today to discuss possible ways to permit the septic system design, I had a discussion with my direct supervisor, Ross Noffsinger, regarding the possibility of issuing a waiver to surface water using a conventional septic system and not requiring a Category III Advanced Wastewater System (AWWTS). Given the characteristics of the subject property and proposed design, Ross and I both agree that a waiver to surface water can be issued using a conventional septic system similar to the design that was permitted on 6/25/2010, but with minor adjustments to maximize the separation distance. Thanks Jay ,Tames ",Tay" Crewdson, P.E. Civil Engineer Municipality of Anchorage - Development Services Division On-Site Water and Wastewater Program Location: 4700 Elmore Road Mail: P.O. Box 196650, Anchorage, AK 99519 v. 907.343.7908 f. 907.249.7601 ~,rewdson, James A. (CrewdsonJA... Crewdson, James A. From: Sent: To: Cc: Subject: Attachments: Cunningham, Kyle B. Friday, May 20, 2011 3:00 PM Crewdson, James A. Ellis, Steve M. 10RansomRidge -Stream feature on parcels 02009213 & 02009295 10Ransom Ridge_FnlZmOut10282010.pdf James, On October 25, 2010, I preformed watercourse mapping for parcel # 02009213 on Ransom Ridge Rd., and parcel # 02009295 on St. James Cir. While on site, I located and mapped one stream feature entering and crossing the target parcels (shown on the attached figure). The feature meets MOA criteria for a stream feature, and has been mapped as such in WMS mapping archives (archived in WMS files as project '10RansomRidge'). The stream has a well defined channel with distinct bed and bank structures from upstream of GPS point 1, downstream to GPS point 13. At the time of my inspection, the majority of the stream flow was infiltrating into the ground upstream of or near GPS point 13. Downstream of GPS point 13, though a continuous surface channel is not present across portions of parcel # 02009295, there is a clearly defined topographic flow path that is hydrologically connected to downstream stream features and/or receiving waters, meeting the MOA definition of a spatially intermittent stream feature. The stream, along its entire alignment, as shown on the attached figure, is subject to all codes and regulation regarding stream features (25' setback, etc). Watercourse mapping completed for this project is shown graphically in attached map. In addition, digital line and point data and GPS location data from these mapping efforts are available from WMS. These data are archived as geographically projected data files and are suitable for use in showing positions of stream and major drainageway features for general planning-level documents and maps. Data are available in ESRl-format shapefiles and can be imported as planimetrically-correct line and point features into a projected AutoCAD drawing environment. However, where stream locations indicated by these data are in error or are not sufficiently accurate for permitting or other purposes, the owner is responsible for providing more precise location surveys and submitting these new data to WMS for review and approval. Please let me know if I can be of any more assistance to you on this project. Kyle B. Cunningham Environmental Specialist MOA Watershed Management Services O¢fice: (,907)34,$-S026 Cell: (907)9,~7-61 f35 ".4ll hail the good life and the true spirit of adventure" 10RansomRidge_F llZmOut10282010..,