Municipality of Anchorage Page ► of 2 -
72-013
DEPARTMENT OF HEALTH AND HUMAN SERVICES
DEPARTMENT
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: 5-k)9zf009y Pit) Number: 060(p7/07
Name:
Wastewater System: ;Er New F1 Upgrade
L �, so SLG.
Address:
ABSORPTION FIELD
IP61-26- m/E v8.
Ppene.
5,46-1.6- var4 flk 98577
o. of Bedrooms:.eme! s:.
T
❑ Deep Trench .Shallow Trench ❑ Bed ❑ Mound ❑ Other
LEGAL DESCRIPTION
Soil Rating:
O• P"GPD/S . Ft.
Total Depth from original grade:
S •S'
Lot: Block: Subdivision:
Depth to pipe bottom from original grade:
Gravel depth beneath pipe
, U 0X)6 5/,P
1-411:11 Ft.
3.7 3 .9 Ft.
Township:
Range:
Section:
Fill added above original grade:
11
Gravel length:
7 Z , S Ft.
t0q Ft.
WELL: ONew ❑ Upgrade
Gravel width:
Number
Z•of lines:
Distance between linFt
•
S- Ft.
Classification (Private, A,B,C):
Total Depth:
Cased To:
Total absorption area:
Pipe material: ;glD P6R-F
fA/VRTE
5'00 Ft.
20 Ft.
9(03 SQ. Ft.
14.5 7—M Dgo? Li P V. C.
Driller:
S6,41-/V,4,u k), TFT_ y)ECL
Date Drilled:
4 /qy
Static Water Level:
►S Ft.
Installer:
Ptso7'c=c.i- QA)sr.
Date installed:
I 2.! -9y
Yield:
Pump Set at: I
I
Casing Height Above Ground:
TANK
2- GPM
U K Ft.
I Ft.
SEPARATION DISTANCES
iXseptic ❑ Holding ❑ S.T.E.P.
To
Septic
Absorption
Lift
Holding
Public/Private
Manufacturer:
Capacity in gallons:
From
Tank
Field
Station
Tank
Sewer Lines
4A)cH GE NK
/GOO
Welt'
/00 �F
/00 /.,L2S
i
+
Material:
S� EEG
Number of Compartments:
Z
SurfaceLIFT
STATION
Water
100,4-
10614-
Lot
Line
/0
,
/O *-
!=I��
"Pump on" level at:
"Pump off" lev High water alarm at:
Foundation
p3 f
12.1 1
Curtain
Pump Make & Model
Electrical Inspections performed by:
Drain
NON
KN
WN
BENCH MARK
Remarks:
Location and Description:
TOP OF PORCHS E,uTr;tcit
13ETW EN UCTU lZ ES
Assumed Elevation:
/DO" O Ft-
ENGINEW,S SEAL
'
S & S ENGINEERING`
17034 Eagle River Loop Road, No. 204
Inspections performed by: Enalle Rover, Alaska 99577 Dates: lst s -13 -94
2nd s- f7 -941
Department of Health and Human Services approval
Iti Cl
�W.�a''`
-?4-
y¢
Reviewed and approved by: % Date: - 26
72-013 (Rev. 9/91) MOA 25
Permit No. SW940094
Page 2 of 2
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 - Anchorage, Alaska 99519-6650 e Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Legal Description rATNODE SUBDIVISION, BLOCK 1, LOT 1
PID No.:
05067107
C04 C05
MT1 C07
GRADE71.0
MT2 C09
-FINAL
70.7'
70.3'
........................
...
. .............. ............ .. ...........................
.................................... ...
67.87
NEW
67.6
1500 GAL
67.5:
R
27.1111
S.T.
1
�*63.
66.8'
63.6"
....................... .. .... .........................................................................
TANK
FROM TANK
............ ..........................................
1,
63.1'
........... .........................................................................
A i B
FCO
25.5:
5.5
COI
58.5::
48.0
CO2
101.5
86.0
CO3
113.6
97.5
....... ...... ..... . ... . . ......... . ... ......
............
........... . ......... .......... ......... ............... ... ...... ...........
C05
110.0
97.0
C06
134.0
124.0
C07
172.6
168.5
C08
147.5
135.0
v
C09
182.0
175.0
MT1
168.6
163.0
MT2,148.$ _136.5
............. .......................... .................................................................. ....................................
.............................. .........
.......... .........................
... ............ .......................
:A
5 BDRM.:HOUSE
NEW TRENCHES
.............. ........................ ..................................... ... .......................................... ......
Fco'
......................................................
............... . .. ......
col
TBM
:M
C07 T1
DOL
0
cog C06
C 05:
.................................... .......... ........... ..........................
C04
.... ...... .
0
CQ2 ......................... .......................
MT2:: co3
ENGINEER'S SEAL
10o +
cob
. . . . . . . . . . .
NEW 1500:
GAL. SEPTIC TANK
................ ........... ...........
SCALE 1" = 40,
72-013 A (1/93)'
by
DOC Co. dba
SULLIVAN WATER WELLS
P.O. BOX 670272, CHUGIAK, ALASKA 99567 • TELEPHONE 688.2759
OWNER OF LAND orEG, 4 Ca.v S
ADDRESS O 1 a
LEGAL DESCRIPTIO o r 1 N Oxy "
DATE -.Started Ended
PERMIT NUMBER
DEPTH OF WELL sa0
i
STATIC LEVEL OF WATER FT.
DRAW DOWN FT
GALS. PER HR /0110_
KIND OF CASING 6�
KIND OF FORMATION:
From Ft. to__C�—Ft.
- e,'s/,-JA S 7-ir itJ
From
Ft. to
Ft.
From Ft. to__J_Ft.
_
From
Ft. to
Ft.
From _Ft. to -S --Ft.
S14 t r iiL
From
Ft. to
Ft.
From _Ft. to_rX--Ft.
c p e.K 641 T
From
Ft. to
Ft,
From Ft. to4-5_'_Ft.
From Ft. to/ 6 U Ft.
From_/6© Ft. to 0 Ft.
AAE", -AC
6,F40J t�/� /� c.�'7G/C J%l
� �
3 c eC
From , Ft. to
)Vr �' WET
rom Ft. to
Froin Ft. to
Ft
Ft.
Ft.
Fro as Ft. to,?9S" Ft.d_r-&,(
Fro Ft. to 30r Ft
C 6At--- �'J From Ft. to
Q�&,je le 6Q wl jF'
�_� 1��+�'� � rom F $0
Ft.
Ft.
From - Ft. tol 7 Ft. _
From�_Ft. to 3�rv7z�r
Ft.,A
r
From.3 Ft. to say Ft.
4,60R a GIC 6RtF(_-^J From ((Ft. to
W_L KAELI 1 h-�,�cTF m� Ft. o� ~�
c_ic A A�/: C From Ft. to
Ft.
Ft.
Ft.
From Ft. to - Ft.
From
Ft. to
Ft.
From—Ft. to Ft.
From
Ft. to
Ft.
From Ft. to Ft.
From
Ft. to
Ft.
From Ft. to Ft.
From
Ft. to
Ft.
From Ft. to Ft. From Ft, to Ft
MISCL. INFORMATION:
DRILLER'SNAME it -"�
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW940094
DESIGN ENGINEERS & S ENGINEERING
OWNER NAME:DISOTELL CARL A
OWNER ADDRESS:18525 JAMIE DR
PARCEL ID:05067107
LEGAL DESCRIPTION: PATNODE BLK 1 LT 1
LOT SIZE: 71733 (SQ. FT.)
NUMBER OF BEDROOMS: 5 THIS PERMIT: 5
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
PAGE 1 OF 1
DATE ISSUED: 3/01/94
EXPIRATION DATE: 3/01/95
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 OR 343-4681 AFTER BUSINESS HOURS
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
THIS IS A REVISION TO THE ORIGINAL PERMIT DATED 030194.
THE REVISION IS FOR A FOUR BEDROOM RESIDENCE BASED OF THE
DESIGN DATED 04/22/94.
RECEIVED
ISSUED BY:
BY : I DATE: e_ o
- f`-2.' DATE : Z G G
NI
nom\
April 22, 1994
ROBERT SHAFER, P.E.
ROGER SHAFER, P.E.
CIVIL ENGINEERS
(907) 694-2979
FAX 694-1211
HEALTH AUTHORITY
APPROVALS Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
825 'L' Street RECEIVED
P.O. Box 196650
SEWER & WATER Anchorage, Alaska 99519-6650 APR
2 51994
MAIN EXTENSIONS
ivIuniclpality of Anchorage
Dept. Health & Human Services
SEWER & WATER REFERENCE. Patnode Subdivision, Block 1, Lot 1
INSPECTION
ENGINEERING STUDIES Request you re -issue permit #SW940038 to drill a well and install a septic
AND REPORTS
system to serve the proposed five bedroom house on the referenced
property.
WELL INSPECTION The original permit was for a four bedroom house. The well has been drilled with
& FLOW TEST existing permit #SW940038, attached is the well log.
Test holes were excavated and percolation tests performed. The approximate
SITE PLANS location of the test holes are located on the attached site plan. The monitoring
tubes within the test holes have been checked and found to be dry.
This property has enough area for a future septic upgrade which can be seen on
ROAD DESIGN the attached site plan. We do not anticipate any adverse effects on neighboring
properties by the installation of the proposed septic system.
SOIL TEST If you have any questions, or require additional information for your review,
please contact us.
,
PERCOLATION Sincer
TEST
STRUCTURAL&
R rt A. Shafer, P.E.
MECHANICAL
INSPECTIONS
RASIL SU/Isu
ON SITE
WASTE WATER
DISPOSAL SYSTEM
DESIGN
17034 NORTH EAGLE RIVER LOOP • SUITE 204 • EAGLE RIVER, ALASKA 99577
F -
Z
La
U
W
U)
O
x
ko
/o l
y /
U /o /
aF E
d V)
33 SECTION LINE ESMT.
/
I�
O
Z
O O Z
�z Qao
W�
5
=
1
t
[ �
d Owe
Cr T r:
of zwj O=oN
L`'LJ°n(f)
O
o
S4.
I �z
d Q a<z
Z
LdNO
F -
Z
La
U
W
U)
O
x
ko
/o l
y /
U /o /
aF E
d V)
33 SECTION LINE ESMT.
/
I�
O
Z
O O Z
�z Qao
W�
5
=
o
V) Zoo
U)
U)
d Owe
of zwj O=oN
L`'LJ°n(f)
O
o
d
I �z
d Q a<z
Z
LdNO
/
L�DJ
A 0Z3:O0�>
�a
N
pq VT: � � �Q-f
CF <
^
F --I
I
S zn.o i- w
woo
_jw
N
W ww>-Um�O
/
H
a wo�F-Nw�
Nr>
H
P W
o
Wa l,J 0
0 F a
O
= mOrnwaz
F- F- w O
C) F-
WZ�D:f fnU
Dom www
Z�Y
Zaoix
/
o
u
H 1 t=-�v�
Om�O
Y
Z) N><V)
c�oa3
O
vi
�O F -Z
V)< F-ooary
'
J
Q
i
Ld
O
Va
L,J
zO
�
Y
000
U)
z0
0, -,Ln
N o Z
E-+ O °�- �>
Q
W
p
w
H U M
�� �
F-- U Z E� �
UZ O CY
o
11 C) II
_j 04O
WWw�E-
F-
QS
II o0 ���W�
<�
�pv�\
Q
3
Lf)
M J 0Lo
t1) M d
C7
Q
w Io ON r Q
J
p
Q
F -
Z
La
U
W
U)
O
x
ko
/o l
y /
U /o /
aF E
d V)
33 SECTION LINE ESMT.
/
W�
5
/ W
o
/
0
o
A
LoLo
x
Q
I Lo
^
F --I
/ J
Q
W E-
"
0 U)
U
/
oH/
P W
o
N
/
J
/
o
u
d
w z
.
/
- ..
Ndld ITIS
31doS
'05 = j
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MATERIAL SPECIFICATIONS
REFERENCE: Patnode Subdivision, Block 1, Lot 1
GENERAL:
1. The scope of this project includes the installation of a 1500 gallon septic
tank and five foot wide drainfields to serve the proposed five bedroom
residence for the referenced property.
2. Construction shall be in accordance with the approved site plan and design
drawings; Municipal permit with any special provisions or conditions; and all
applicable State and Municipal Wastewater Disposal Regulations.
3. The contractor shall be responsible for obtaining any necessary
underground utility locates.
4. Unless specifically agreed otherwise, the property owner shall be
responsible for final grading areas subsequently depressed from soil
settling. On all leachfield mound systems, the property owner shall be
responsible for ensuring a satisfactory vegetation growth over the mounded
area.
5. Contractors installing wastewater disposal systems must be certified by the
Municipal Health Department for system installations. Owners installing
their own systems must also receive prior approval from the Municipal
Health Department.
SEPTIC TANK INSTALLATION.
1. A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" cleanouts for pumping access.
2. The septic tank shall be sufficiently bedded to prevent settling or shifting of
the tank.
3. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
Page Two
Patnode Subdivision, Block 1, Lot 1
April 22, 1994
4. Septic tanks installed with less than 4 ft. of cover shall be insulated.
5. A foundation cleanout shall be installed one to four feet from the building
foundation. In the line between the tank and the leachfield there shall be
two adjacent cleanouts (unless an effluent pumping system exists within the
septic tank). These cleanouts shall be located on undisturbed soil not more
than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward
the leachfield. The second cleanout shall be to clean toward the septic
tank.
6. Final grading over the septic tank shall be such that a positive slope exists
away from the septic tank.
ABSORPTION TRENCH/DRAINFIELD INSTALLATION:
1. Excavate the proposed trench to the dimensions shown on the design. The
bottom of the excavation shall be within 2 inches of level. If the sidewalls
of the excavation become smeared, they must be raked or scratched
(ruffed -up) before gravel (sewer rock) placement.
2. Once the gravel is installed, the distribution pipe is to be installed level with
the perforations faced downward. Gravel is then to be placed over the
distribution pipe to provide a minimum of 2 inches of cover over the pipe.
3. A silt barrier must be installed between the final gravel layer and the native
soil backfill. Ensure the silt barrier covers the entire gravel surface before
placing backfill.
4. Monitor tubes shall be of four (4) inch diameter and installed approximately
in the locations shown on the design. The portion of the monitoring tube
extending through the gravel shall be perforated from the bottom of the
trench to the invert of the distribution pipe. This is equivalent to the
effective depth of the gravel as noted on the design.
5. Backfill over the final gravel layer must not be less than twenty-four (24)
inches. Insulation must be installed when the backfill depth is less than
thirty-six (36) inches. The finish grade over the trench must be mounded
to prevent the formation of a depression after settling.
Page Three
Patnode Subdivision, Block 1, Lot 1
April 22, 1994
MINIMUM MATERIAL SPECIFICATIONS:
1. Any septic tank proposed for installation must be constructed by a
Municipally approved septic tank manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Type of Pipe Perforated Solid
Cast Iron Yes Yes
ASTM D3034 (PVC) Yes Yes
ASTM F810 (HDPE) Yes No
ASTM D2662 (ABS) Yes Yes
Use of a type of pipe other than listed above must be approved by the
inspecting engineer.
3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow
Chemical Company Styrofoam Hi or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must
be installed between the final leachfield gravel layer and the native soil
backfill.
6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with
less than 3% passing the #200 sieve.
7. When sand is being used as a filter material, it's gradation specifications
must conform to current M.O.A. or D.E.C. requirements.
Page Four
Patnode Subdivision,
April 22, 1994
INSPECTIONS:
Block 1, Lot 1
Typically there will be a minimum of three (3) inspections required during the
installation of the wastewater disposal system. These inspections will occur as
follows:
1. The first inspection must be conducted after the excavation of
ditches, pits, trenches, or beds and before the installation of any
gravel. A septic tank may be set in place, but may not be backfilled
before this inspection.
2. The second inspection must be conducted after the placement of the
silt barrier, gravel, distribution lines, standpipes, cieanouts, and
insulation, but before the placement of any other backfill.
3. The final inspection is to occur upon final grading of the property.
Often there will be more than these 3 inspections required. Especially with the
installation of multiple trenches, sand filters, pressurized distribution systems, etc.
Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start
of construction. If necessary, a pre -construction meeting will take place on-site.
The inspecting engineer will not coordinate, direct or control in any way the
contractors activities.
The owner shall contract with the contractor to perform the work outlined in these
specifications and plans and in accordance with the attached M.O.A. permit.
There will be no contractual arrangement existing between the contractor and
S & S Engineering. S & S Engineering shall be the owner's representative and will
inspect the work as stated above to document the contractors activities. Final
acceptance of the contractors work rests with the owner and the M.O.A.
S & S Engineering shall have no liability to the owner or to others for acts or
omissions of the contractor or any other persons performing work on this project
or the failure of the contractor to carry out the work in accordance with these
construction documents. S & S Engineering's inspecting engineer will not be
responsible for the construction means, methods, techniques, sequence,
procedures or the safety precautions incident to this project.
CONTRACTOR/OWNER
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL AND WAS
PERMIT NUMBER:SW940038
DESIGN ENGINEER:S & S ENGINEERING
OWNER NAME:DISJOTELL JANET L
OWNER ADDRESS:PQ BOX 770213R
EAGLE RIVER, AK 99567
PARCEL ID:0506710
LEGAL DESCRIPTION: TNODE BLK LT
LOT SIZE: 71733 (SQ.\4HIS
.)
NUMBER OF BEDROOMS: PE MIT: 4
TER DISPOSAL SYSTEM PERMIT
1
THIS PERMIT IS FOR THE CO TRU TION OF:
DISPOSAL FIELD /SEPTIC TAN //WELL SYSTEM
ALL CONSTRUCTION MUST BE IN CCORDANCE WITH:
1. THE ATTACHED APPROVED D S N.
2. ALL REQUIREMENTS SPEC
ED N
15.55 AND 15.65 AND TH STAT
REGULATIONS (18AAC72) ND DRI
3. THE ENGINEER MUST NOT Y DHHS
PRIOR TO EACH INSPECT ON. PFA
CALLING 343-4744 OR 343-4681
4. FROM OCTOBER 15 TO A RIL 15 A
ABSORPTION SYSTEM UN ER.CONSTR
WEATHER MUST BE EIT ER:
PAGE 1 OF 1
DATE ISSUED: 3/01/94
EXPIRATION DATE: 3/01/95
ANCHORAGE NIC AL C
OF ALASKA W TE"
ER
GER R GULA IOr
EAST H RS
NOTI ICA ION
R BUS NE HOUR
SU FACE SOI
UCT DUR NG FREEZI
A. OPENED AND CLOSE ON HE SAME
B. COVERED, SEALED ND H ATED TO
5. THE FOLLOWING SPEC AL PRO ISION .
SPECIAL PROVISIONS:
RECEIVED BY:
ISSUED BY:
�Y v
:EVEN FREEZIN
E CHAPTERS
SPOSAL
(18AAC80).
nein\
February 13, 1994
ROBERT SHAFER, P.E.
ROGER SHAFER, P.E.
CIVIL ENGINEERS
(907)694-2979
FAX 694-1211
HEALTH AUTHORITY
APPROVALS
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
825 'L' Street
P.O. Box 196650
SEWER & WATER
Anchorage, Alaska 99519-6650
MAIN EXTENSIONS
SEWER & WATER
REFERENCE. Patnode Subdivision, Block 1, Lot 1
INSPECTION
ENGINEERING STUDIES
Request you issue a permit to drill a well and install a septic system to
AND REPORTS
serve the proposed four bedroom house on the referenced property.
Test holes were excavated and percolation tests performed. The approximate
WELL INSPECTION
location of the test holes are located on the attached site plan. The monitoring
& FLOW TEST
tubes within the test holes have been checked and found to be dry.
This property has enough area for a future septic upgrade which can be seen on
SITE PLANS
the attached site plan. We do not anticipate any adverse effects on neighboring
properties by the installation of the proposed septic system.
If you have any questions, or require additional information for your review,
ROAD DESIGN
please contact us.
Sincerely,
SOIL TEST
� /�'/
A. Shafer, P.E.
PERCOLATION
TEST
6 RAS/LSU/Isu
STRUCTURAL&
MECHANICAL
INSPECTIONS
ON SITE
WASTE WATER
DISPOSAL SYSTEM
DESIGN
17034 NORTH EAGLE RIVER LOOP • SUITE 204 • EAGLE RIVER, ALASKA 99577
I
Z
1--O O Z
w Z U O O
30 Q ~
__
aN zCo
�a Z���
zw00O=00 W
~ Z
J a z l, 1) J
S
ozaooOr>-
� (L H w
wwUm�O
F- w
wvi>l-Zw�
Llj Ljjwp
Nz
V) -j Of LU
W Z - �
}-I i- � U
�3a N>QV)
NV)Q �000
`way.
Y•j'
, e�
—o
l
I
�
;
0 p
a
w...
wa
a ~Ua
•
Lo
a' OJ X
*/
.+�,....
w
Ur
I
Z
1--O O Z
w Z U O O
30 Q ~
__
aN zCo
�a Z���
zw00O=00 W
~ Z
J a z l, 1) J
S
ozaooOr>-
� (L H w
wwUm�O
F- w
wvi>l-Zw�
Llj Ljjwp
Nz
V) -j Of LU
W Z - �
}-I i- � U
�3a N>QV)
NV)Q �000
o
I�
, e�
—o
O
;
0 p
a
w...
wa
a ~Ua
•
Lo
a' OJ X
*/
.+�,....
w
Ur
I- z
0O J<
C
N�
W
_
F-
a�
X Z
o�
Om EEO
�w�
(.)0 a. 3
o
, e�
—o
Q
C
N�
W
U-
r��
�w�
V)
0 C
Q
��
C4p
o
ofO
�
CLL,
ww�z
w
E"C/��
n
004
J \
moo
aZ
3
�i�rnbo
ago
W
�r��
LU
J
p
Q
z�ffi
Na O
33 SECTION LINE ESMT. r w�
�a>8
31VOS
NVId 31lS
'OS = AG
e Municipality of Anchorage
t DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
PERFORMED FOR: '/ t S nTi►�t.�.. �►�s� DATE PER RM I l -1 '
LEGAL DESCRIPTION: �o•r gjyYi 1 I�DA+� a�4.s�v Township, Range, Section:
DEPTH SLOPE SITE PLAN
14
15
16
17
18
19
20
COMMENTS
S
/-,\I /Sa
Lit Lr A < S► L'j-
Mix
WAS GROUND WATER `
ENCOUNTERED? O
S
IF YES, AT WHAT 111 L
0
DEPTH?
P
E
Depth to Water After
Monitoring? vfd4— Date: 2, 1bh4
Reading
Date Gross
Time
Net
Time
Depth to
Water
Net
Drop
'So
eA
Z
S
Ifl HI•S
,�~
� 4N
3
' 5s;-
to W►.
.5
4..
A
Z:os
Lo *A.j
PERCOLATION RATE •3 (minutes/inch) PERC HOLE DIAMETER V
TEST RUN BETWEEN • A' F�AND -4,0 FT
PERFORMED BY: i" agle River Loop Road No. 2Qd 1
r-agle River, Alaska 99577
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELItd9
72-008 (Rev. 4/85)
CERTIFY THAT THIS TEST WAS PERFORMED IN
r ON THIS DATE. DATE:
(ENGINEER'S SEAL)
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650 S.
SOILS LOG — PERCOLATION TEST
PERFORMED FOR: V/ Sore- . �DATE PERFO
1 1 Township, Range, Section:
LEGAL DESCRIPTION: l-'bi � �lL � ��i'''m'��SCJ p' g '
??T SLOPE SITE PLAN
ER
1 ✓ opN N
A,� r N
2
v
3
4 /o
5 ( O %1'� I! s�
L-►L'a-r stLsr
8-
9-
10-
11 9 1011
12-
13 � P
14
7
15
16-
17
18-
19-
20-
COMMENTS
81920COMMENTS
WAS GROUND WATER
ENCOUNTERED?�
S
IF YES, AT WHAT L
0
DEPTH? ~ A P
E
Depth to Water After
Monitoring? 2E4 Date:b��L�
Reading
Date Gross
Time
Net
Time
Depth to
Water
Net
Drop
p.pCIL I b
3% Z
s-
�
HA -z
7 ` l o
D Wl "L
L{ "
PERCOLATION RATE )3o$ (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN -511r'
• FT)AND *•5— FT
S & S ENGINEERING
PERFORMED BIZ age River toop Road No. 2W
I
ACCORDANCE Milt /tf3bwrAAl§axkw9 bPAL GUIDELINES
72-008 (Rev. 4/85)
CERTIFY THAT THIS TEST WAS PERFORMED IN
THIS DATE. DATE:
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MATERIAL SPECIFICATIONS
REFERENCE: Patnode Subdivision, Block 1, Lot 1
GENERAL:
The scope of this project includes the installation of a 1250 gallon septic
tank and five foot wide drainfields to serve the proposed four bedroom
residence for the referenced property.
2. Construction shall be in accordance with the approved site plan and design
drawings; Municipal permit with any special provisions or conditions; and all
applicable State and Municipal Wastewater Disposal Regulations.
3. The contractor shall be responsible for obtaining any necessary
underground utility locates.
4. Unless specifically agreed otherwise, the property owner shall be
responsible for final grading areas subsequently depressed from soil
settling. On all leachfield mound systems, the property owner shall be
responsible for ensuring a satisfactory vegetation growth over the mounded
area.
5. Contractors installing wastewater disposal systems must be certified by the
Municipal Health Department for system installations. Owners installing
their own systems must also receive prior approval from the Municipal
Health Department.
SEPTIC TANK INSTALLATION:
1. A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" cleanouts for pumping access.
2. The septic tank shall be sufficiently bedded to prevent settling or shifting of
the tank.
3. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
Page Two
Patnode Subdivision, Block 1, Lot 1
February 13, 1994
4. Septic tanks installed with less than 4 ft. of cover shall be insulated.
5. A foundation cleanout shall be installed one to four feet from the building
foundation. In the line between the tank and the leachfield there shall be
two adjacent cleanouts (unless an effluent pumping system exists within the
septic tank). These cleanouts shall be located on undisturbed soil not more
than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward
the leachfield. The second cleanout shall be to clean toward the septic
tank.
6. Final grading over the septic tank shall be such that a positive slope exists
away from the septic tank.
ABSORPTION TRENCH/DRAINFIELD INSTALLATION:
1. Excavate the proposed trench to the dimensions shown on the design. The
bottom of the excavation shall be within 2 inches of level. If the sidewalls
of the excavation become smeared, they must be raked or scratched
(ruffed -up) before gravel (sewer rock) placement.
2. Once the gravel is installed, the distribution pipe is to be installed level with
the perforations faced downward. Gravel is then to be placed over the
distribution pipe to provide a minimum of 2 inches of cover over the pipe.
3. A silt barrier must be installed between the final gravel layer and the native
soil backfill. Ensure the silt barrier covers the entire gravel surface before
placing backfill.
4. Monitor tubes shall be of four (4) inch diameter and installed approximately
in the locations shown on the design. The portion of the monitoring tube
extending through the gravel shall be perforated from the bottom of the
trench to the invert of the distribution pipe. This is equivalent to the
effective depth of the gravel as noted on the design.
5. Backfill over the final gravel layer must not be less than twenty-four (24)
inches. Insulation must be installed when the backfill depth is less than
thirty-six (36) inches. The finish grade over the trench must be mounded
to prevent the formation of a depression after settling.
Page Three
Patnode Subdivision, Block 1, Lot 1
February 13, 1994
MINIMUM MATERIAL SPECIFICATIONS:
1. Any septic tank proposed for installation must be constructed by a
Municipally approved septic tank manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Type of Pipe Perforated Solid
Cast Iron Yes Yes
ASTM D3034 (PVC) Yes Yes
ASTM F810 (HDPE) Yes No
ASTM D2662 (ABS) Yes Yes
Use of a type of pipe other than listed above must be approved by the
inspecting engineer.
3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow
Chemical Company Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must
be installed between the final leachfield gravel layer and the native soil
backfill.
6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with
less than 3% passing the #200 sieve.
7. When sand is being used as a filter material, it's gradation specifications
must conform to current M.O.A. or D.E.C. requirements.
Page Four
Patnode Subdivision,
February 13, 1994
INSPECTIONS:
Block 1, Lot 1
Typically there will be a minimum of three (3) inspections required during the
installation of the wastewater disposal system. These inspections will occur as
follows:
1. The first inspection must be conducted after the excavation of
ditches, pits, trenches, or beds and before the installation of any
gravel. A septic tank may be set in place, but may not be backfilled
before this inspection.
2. The second inspection must be conducted after the placement of the
silt barrier, gravel, distribution lines, standpipes, cleanouts, and
insulation, but before the placement of any other backfill.
3. The final inspection is to occur upon final grading of the property.
Often there will be more than these 3 inspections required. Especially with the
installation of multiple trenches, sand filters, pressurized distribution systems, etc.
Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start
of construction. If necessary, a pre -construction meeting will take place on-site.
The inspecting engineer will not coordinate, direct or control in any way the
contractors activities.
The owner shall contract with the contractor to perform the work outlined in these
specifications and plans and in accordance with the attached M.O.A. permit.
There will be no contractual arrangement existing between the contractor and
S & S Engineering. S & S Engineering shall be the owner's representative and will
inspect the work as stated above to document the contractors activities. Final
acceptance of the contractors work rests with the owner and the M.O.A.
S & S Engineering shall have no liability to the owner or to others for acts or
omissions of the contractor or any other persons performing work on this project
or the failure of the contractor to carry out the work in accordance with these
construction documents. S & S Engineering's inspecting engineer will not be
responsible for the construction means, methods, techniques, sequence,
procedures or the safety precautions incident to this project.
CONTRACTOR/OWNER
Municipality of Anchorage
• e.c =_
Development Services Department
Building Safety Division
Onsite Water & Wastewater Program
4700 South Bragaw SL
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907)343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 050-671-07 HAA# 4&-)Ca/7
1. GENERAL INFORMATION Expiration Date: 2,3 1 1 OS'
Complete legal description PATNODE
SUBDIVISION;
LOT 1
BLOCK 1,
Community Class Well
❑
Public Water System
Location (site address or directions)
1805 JAMIE
DRIVE *
EAGLE RIVER, AK 99577
Current Property owner(s)
Mailing address
Lending agency
Mailing address
DAN & BOBBIE WEIGMAN Day phone 694-5015
1805 JAMIE DRIVE * EAGLE RIVER, AK 99577
Day phone
Real Estate Agent SHAYLENE ERNISSE w/ PRUDENTIAL VISTA Day phone
Mailing address 4241 "B" STREET * ANCHORAGE, AK 99503
Unless otherwise requested, HAA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 5
3. TYPE OF WATER SUPPLY:
Individual Well
E
Individual Water Storage
❑
Community Class Well
❑
Public Water System
❑
351-9916
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding tank
❑
Community On-site
❑
Public Sewer
❑
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
Note: Alaska Water and Wastewater Consultants, Inc. shall be paid $ I,Qg5at, or prior
to closing for the engineering services provided.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm ALASKA WATER & WASTEWATER CONSULTANTS, INC.
Address 6901 DEBARR ROAD, SUITE 28 * ANCHORAGE, AK 99504
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
Engineer's Comments:
In conducting this evaluation, AWWC, Inc. attempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines & Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily identifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. AWWC, Inc. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will it confer any legal right whatsoever.
5. DSD SIGNATURE
Approved for - bedrooms.
Disapproved.
Phone
337-6179
Date 1 l[07—
Conditional
approval for bedrooms, with the fllowing stipulations:
Attachments:
HAA Checklist
Septic System Advisory
Well Flow Advisory
Manitenance Agreements
Supplemental Engineer's Reort
Other
Jti(t
�Y0PA�r���
WATER AND m'
(n/� AS E%kT CR
PROGRAM
(/111111
i� _�
gy. /D
Original Certificate Date: J ��
(Rev. 12/0 _W
1)
Municipality of Anchorage
Development Services Department
�J Building safety Division
On4b Ws%rS WaatewawProgram
4700 South Bragew SL
P.O. Boa 798850 Anchorage, AK 6951118650
www.dAndwmge akus
(907) 943.7904
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: PATNODE SUBDIVISION: LOT 1, BLOCK 1, Parcel ID: 050-671-07
A. WELL DATA
Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (YM) YES
Date completed 4/1994 Sanitary seat (YIN) YES Wires property protected (YM) YES
Total depth 500 ft. Cased to "20.3 ft. Casing height (above ground) 12 in.
FROM WELL LOG AT INSPECTION
Date of test 4/1994 4/17/2002
Static water level 15 ft. 42 ft.
Well production 2.0 g,p,m, ••0.35 —
g -p.m -WATER SAMP E RESULTS: ••500 GALLONS OF STORAGE INSTALLED
Coliform colonies/100 ml. Nitrate ' 3(0-1 g./L. Other bacteria -4— colonies/100 ml.
Arsenic: N/A mg./L. Date of sample: 4/18/2002 Collected by: AWWC, INC.
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material STEEL Date installed 5/13-17/1994
Tank size 1500 gal. Number of Compartments 2 Cleanouts (Y/N) YES
Foundation cleanout (YM) YES Depression over tank (Y/N) NO High water alarm (Y/N) N/A
Date of pumping 4/23/2002 Pumper JR'S PUMPING
C. ABSORPTION FIELD DATA
Date installed 5/13-17/1994 Soil rating OE> ft'/bdrm) 0_8 System type TRENCH
Length 104 ft. Width 5 ft. Gravel below pipe 3.7/3.9 ft_
Total depth 7.5 ft. Eff. absorption area963 ft' Monitoring tube YES Depression over field NO
Date of adequacy test 4/17/2002 Results (Pass/Fail) PASS For 5 bedrooms
Fluid depth in absorption field before test 0 In. Water added 765 gal. New depth 3 in.
Elapsed Time: 54 min. Final fluid depth 0 In. Absorption rate >= 750+ g,p,d,
Any rejuvenation treatment (past 12 mo.) (YM 8 type) NONE KNOWN If yes, give date -
D. LIFT STATION
Date installed
"Pump on" level at _in.
E. SEPARATION DISTANCES
High water alarm level at
Cycles tested Meets alarm 8 circuit requirements?
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tankAiR station on lot 100'+
Absorption field on lot 100'+
Public sewer main N/A
On adjacent lots
On adjacent lots 100'+
Public sewer manhole/cleanout N/A
Sewer /septic service line 25'+ Holding tank N/A
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 58+ Property line 5'+ Absorption field 5'+
Water main N/A Water service line 10'+ Surface water 100'+
Wells on adjacent lots 100'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 109+ Building foundation 10'+ Water main N/A
Water service line 10'+ Surface water 1009+ Driveway, parking/vehicle storage 25'+
Curtain drain NONE KNOWN Wells on adjacent lots 100'+
F. COMMENTS
G. ENGINEER'S CERTIFICATION
1 certify that 1 have determined through field inspections and a ye
review of Municipal records that Me above systems are in
conformance with MOA IAA guidelines in effect on this date.
Q ' Je a A... ... se:
Engineer's Printed Name JEFFREY A. GARNESS `0 7953
Datea�1)2 �r•^�d Drof�si:00. v
....
HAA Fee $ 375 ,00
Data of Payment rJ a3 -aa
Receipt Number ©a
(Rev. 12/01)
Waiver Fee $
Date of Payment
Receipt Number
•• 05/21/02 14:32 $9072737250 PRUDENTIAL VISTA 0002
I y f
V
1 a
Y,
.... , y..
y
Sj'3 wia N `Y4 liltls 1
'
dm
.. .,'-+' ., J/ Iv,.JI>•�rl- :="iii —'r4- 1A rw 94:wj/iI '
Sse ft%w Llq t' F7enY'•1 AS -BURT • .
1 herebL othat haveryeyed Bowing described
Dcpropert
,a
OF-.qL t►y1 "Anchorage Recording Precinct, Aiaska; �#nd thabthe improve•',
L q n ments situated theredn ire within the Proper' lines and do not
�"�� "ti " f� overlap or encroach ort the ro I m adjacent thereto; that .
i �Q ,•' •.'i r tr P P PertY' Y g J
#e a 9 Z.---- no improvements bn property lying adjacent thereto enaoalch
r t�1 on•the premises In question and that there creno roadways,
1 • ..... transmission lines or other visible easements on said property
except as Indicated hereon.
• `••••' Dated at $agle River; Alaska 4
Robot C. Jc n «? iJ,L
. ; NO. 88D.5 �y� .. .tli� jb say of
ROBERT C. JOHNSON '7pL'10'
'•`t/� �'r..�•w�,,.!''�`S!� .SCAF.E:.'•e^,Ire�t eredLand-SunrfyorNo. 1S''
1" " 6O Boz h-04%'Eagle River', Alaska 99577
.:Phone (907) 694-7543, ;
MUNICIPALITY OF ANCHORAGE
• '� DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services /C/,p
On -Site Services Section kyjF IY pF
P.O. Box 196650 Anchorage, Alaska 99519-6650 Jo�
343-4744 U� %8 �s'0 SON
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL.FOR A SINGLE FAMILY DWELLING
Parcel I.D. # 0 Co .. 671 -07 HAA # 1a1 i�, ci �]
1. GENERAL INFORMATION
Complete legal description Lot 1; Block l'= Patnode subdivision
Location (site address or directions) 18525 Jamie Drive
Eagle River, AK
P,rope, rty,ownerRobert Steiner Day phone 694-7778
-
Mailing `aCldress Box 771168 Earle River AK 99577
Lending agency Day phone
>,
Mailing address f �`
Agent GaryRich% Polar Realty Day phone 242-0069
Address
Unless otherwise requested, HAA will be held for pickup.
2. NUMBER OF BEDROOMS: 5
3. TYPE OF WATER SUPPLY:
Individual well xxx
Community well
Public water
NOTE: If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
4. TYPE OF WASTEWATER DISPOSAL:
Individual on-site XXX
Holding tank
Community on-site
Public sewer
NOTE: If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025 (Rev. 1191) Front MOA 021
� C
5- STATEMENT ,OF'INSPECTION' BY;ENGINEER.
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
`the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or. wastewater. disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in 'effect on the date of this inspection.
Name of Firm S & S ENGINURINGPhone a 2 Z
17034 Eagle River Loop Road No. 204
Address Ea _ - D . r _A6.1-9577 `
Engineer's signature Date q 7
p ROBERT C. COWAN�
�G,A CE-8ao1
•
6. DHHS SIG ATURE �.t ��'�''••`.....,.,«••'•'f ��
Approved for bedrooms.
Disapproved.
Conditional approval for bedrooms, with the following stipulations:
Additional Comments
By: Y
Date
CAUTION
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
`Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in orderto satisfy certainfederal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a' certificate is' issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
.72.025 (Rev. 1/91) Beck MOA M21
y/
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICESI�
Environmental Services Division 0 49.9825 L Street, Room 502 • Anchorage, Alaska 99501 • (907) 343-V�/
�Fa
Health Authority Approval Checklist -
Legal Description: t_C)T- A1 jVL-- � �p�t-�ot�f�s�j Parcel 1. D.: O rO "G -7t -0 7
A. WELL DATA
Well type Iako I �1 I ,, U W'_' If A, B, or C, attach ADEC letter. ADEC water system number `)/
Log present(rWN)
Date completed 4 - 1
Total depth Cased to °�� `/" Casing height (above ground) 12 l
Sanitary seal&)
FROM W' (ELL LOG
Date of test i —j17
Static water level /S
Well production �.
WATER SAMPLE RESULTS:
Coliform C.
Wires properly protected &) \'
AT INSPECTION
('-/.t-9
f,/
g.p.m. / g.p.m.
Nitrate 6.1 3-.). Other bacteria 0
Date of sample: i 3 °t 7 Collected by:
B. SEPTIC/HOLDING TANK DATA
Date installed (v—d I � 5 Tank size /SOo Number of Compartments 2— CleanoutsON) _
Foundation cleanout &N) Depression (Y&QP High water alarm (Y/N) /j4
Date of,0gmping �f� � � 7' :. Pumper die • PPAIY'/W �
C. ABSORPTION FIELD DATA
Date. installed Zi —`lei Soil rating (g.p.d.ff or ftz/bdrm) System type `DAn-Lo\J T�-& e�
Length. 1.0'-A Width Gravel thickness below pipe3 7' , 3,S' Total depth 7. S'
Effective absorption area _ alL Monitoring Tube present &N) -y - Depression over field (Y4 J
Date of adequacy test _ _( - /a - S Results ff ail) of rS ,> For S- bedrooms
Fluid depth in absorption field before test (in.); fl N Immediately afterP-70 gal. water added (in.): -7 5 "
Fluid depth 12- " (ins) Minutes later: 14- Absorption rate = 75'za f g.p.d.
Peroxide treatment. (past 12 months) (Ya /a'dK ������ If yes, give date �G d
72-026 (Rev. 3/96)" „
D. LIFT STATION
Date installed
Manhole/Access (Y/N)
High water alarm level at*
E. SEPARATION DISTANCES
"Pump on"
*Datum
SEPARATION DISTANCES FROM WELL ON LOT TO:
Size in gallons
off' level at*
Septic/holding tank on lot /oc> F On adjacent lots /00 14
Absorption field on lot /b o t + On adjacent lots /00 1
Public sewer main _ J IA Public sewer manhole/cleanout �/
Sewer /septic service line 2 S I+ Lift station IJ 1A
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO:
Foundation 3 Property line /0 14- Absorption field
Water main/service line 14) t Surface water/drainage Ire t> t k Wells on adjacent lots 1 t }
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOTTO:
Property line 1p 1 Building foundation I Z 1 ' Water main/service line
I (> I �-
Surface water 1L --D I �- Driveway, parking/vehicle storage area 5-0 1
Curtain drain tjo^1l< I4^10hlPJ Wells on adjacent lots 1194) 1 4-
F. ENGINEER'S CERTIFICATION
I certify that I have determined thru field inspections and review of Municipal
in conformance wit O Mdes in effect on this date.
Signature
Engineer's Name c7Q�'t f �° co
Date
HAA Fee $
C��D, 41L)
Date of Payment ��%/ C f//
Receipt Number/ / da
72-026 (Rev. 3/96)*
Waiver Fee $
recorQtlp�i�t� s are
Date of Payment
Receipt Number
ROPEgT C CpWM 1,
CE - 8801` 'rf`;v
< .. •' AV
MUNICIPALITY OF ANCHORAGE
• DEPARTMENT OF HEALTH & HUMAN SERVICES_
Division of Environmental Services
On -Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
Parcel I.D. # �a4 -��7/ �' 7 HAA # P for d
1. GENERAL INFORMATION
Complete legal description Lot 1; Btock 1; Patnode Sudivi cion
Location (site address or directions)
18525 Jamie Dkive
Eag.Ze RiveA, AK
Property owner Cant DiAote.Z.Z Day phone
Mailing address 18525 Jamie Dn i.ve Eagte Riven, AK 99577
Lending agency Day phone
Mailing address
Agent Day phone
Address
Unless otherwise requested, HAA will be held for pickup.
2. NUMBER OF BEDROOMS: 5
3. TYPE OF WATER SUPPLY:
Individual well XXX
f.
Community well
Public water
NOTE: If community well system, provide written confirmation from State?- ADEC attesf "
ing to the legality and status of system.
72-025 (Rev. 1/91' F,ont MOA 1,21
1
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe,functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of Firm S & S ENGINEERING Phone
17034 Eagle River Loop oad No. 204
Address Eagle River, Alaska $77
Engineer's signature Date l3
�f � a �•., ,;• � " ";, a til
' 6 64. $ is UevY.aO Y �i d
b o Yl Eelam
VA"Ptim-ts J.
6. DHHS SIGNATURE
Approved for S bedrooms.
Disapproved.
Conditional approval for bedrooms, with the following stipulations:
Additional Comments
/ f By _
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work: ,
72-025 (Rev. 1/91) Back MOA 021
Municipality of Anchorage
MqM
Department of Health and Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: �—T \ C5ue- \ ��,�onc S�a Parcel I.D.
A. Well Data
Well type ?R_\.kT-rz- If A, B, or C, attach ADEC letter. ADEC water system number A
Log present ON) �1 Date completed -1-7 1 Driller .So t -t-, uk,,/
Total depth S-Dtj' Cased to '2- c> `f w Casing height I - 1+
Sanitary seal 6( N) yl Wires properly protected 0) S./
WATER SAMPLE RESULTS:
Coliform D Nitrate A .9 Other bacteria
Date of sample: —43 Collected by:
B. SEPTIC/HOLDING TANK DATA
Date installed (-, - 21 `1 `{ Tank size 1 15-00 Compartments
0
Z
CleanoutsO I) si Foundation cleanout &N) J Depres ion (Yo tA
—T
High water alarm (Y l Alarm tested (Y/NI"
Date of pumping ', —e_ Pumper 'S A
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO:
Well(s) on lot 10 z> \a- On adjacent lots t 4- Foundation to I +_
To property line 83' Absorption field Gb' Water main/service line _ I b L �-
Surface water/drainage \ b n &
72-026(3=)•Front CONTINUED ON BACK PAGE
FROM WELL LOG
AT INSPECTION
rn
Date of test
Static water level
m -O
Z r
Well flow
Z• o
g,p,m,
M
g,p,r n
m o
Pump levell
tJ /L
d•CM
r'I
D
K
o0
SEPARATION DISTANCES FROM WELL TO:
�_ c
o rr
Septic/holding tank on lot
lvo `�
; On adjacent lots
4-
Z
Absorption field on lot
1 b ut1
; On adjacent lots
o `�
j
Public sewer main
I a
Public sewer manhole/cleanout
A r.
Sewer service line
25-
Petroleum tank 2 s- `}
WATER SAMPLE RESULTS:
Coliform D Nitrate A .9 Other bacteria
Date of sample: —43 Collected by:
B. SEPTIC/HOLDING TANK DATA
Date installed (-, - 21 `1 `{ Tank size 1 15-00 Compartments
0
Z
CleanoutsO I) si Foundation cleanout &N) J Depres ion (Yo tA
—T
High water alarm (Y l Alarm tested (Y/NI"
Date of pumping ', —e_ Pumper 'S A
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO:
Well(s) on lot 10 z> \a- On adjacent lots t 4- Foundation to I +_
To property line 83' Absorption field Gb' Water main/service line _ I b L �-
Surface water/drainage \ b n &
72-026(3=)•Front CONTINUED ON BACK PAGE
C. LIFT STATION
Date installed
Manufacturer
Size in gallons Manhole/Access (Y/N)
Vent (Y/N)
High water alarm level
"Pump on" level at
Meets MOA electrical codes (Y/N)
SEPARATION DIST
D. ABSORPTION FIELD DATA
FT STATION TO:
On adjacent lots
Cycles
"Pump off"
Surface water
Date installed Ci -2\ - `l 4 Soil rating (GPD/Ft2) O,`3 System type
Length 1a4' Width S' Gravel thickness 3,1, 3,9 Total depth 7, s"
Total absorption area .3 Cleanout present(N __Depression over field (Y(@ _
Date of adequacy test -- awl Results (pass/fail) —" for S' Bedrooms
Water level in absorption field before test After test
Peroxide treatment (past 12 months) ( A If yes, give date '� A
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
Well on lot I -oc> On adjacent lots / co (+ Property line / a /+
To building foundation /,21) To existing or abandoned system on lot ''f'
On adjacent lots '30 14- Cutbank Al' Water main/service line 1c), 4-
Surface water 100 Driveway, parking/vehicle storage area So �
Curtain drain "Jo,,l�_: /� do a,,(
E. ENGINEER'S CERTIFICATION
l certify that l have checked, verified,
Signature
Engineer's
Date
all MOA and HAA guidelines in effect do=xhe d ,p,,1 s inspection.
d_
HAA Fee $ X00 , Waiver Fee $
Date of Payment r/5` y7`/ Date of Payment
Receipt Number D o a V C 8/1 Receipt Number
72-026 (3/93)' Back