HomeMy WebLinkAboutUPPER EAGLE RIVER ESTATES BLK 1 LT 3BUpper Eogl River Estates Block Lot 3B #050-781-03 /'~% MUNICIPALITY OF ANCHORAGE '~ · DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME PNONE [] NEW LEGAL DESCRIPTION m~ ~ Manufacturer [ ~' ~ - [ Material Ne. of compartments ~ ~ Liq. capacity in gallons Inside length Width Liquid depth ]F HOME.DE: ~ DISTANCE TO: Well F°undati~n~o ~t -- No. oflines/ Length of oa~ / Totallongt~f~ / Tronchwid ches ~ ~ ~ Top of ti]e to finish grade r~ /, -- Materia] ben,ath tile' '7'Z ~ ~ Type of crib Crib diameter Crib depth Total effective absorption area ~ Well Building foundation Nearest lot line ~ DISTANCE TO: ~ Class Depth ] Driller Distance to lot line PERMIT NO. m ~ ~ Absorotion ~ ~ 10:~ ~uil~n d So.or line Septic tank OTH~B PIPE MATERIALS SOIL TEST RATING INSTALLER 72-013 (Rev. 3~78) Permit Applicant: /~UNICIPALITY OF ANCHORAGEj~ Department , Health and Environmenta.)rotection 825 L Street, Anchorage, AK. 99501 264-4720 * * * HANDWRITTEN PERMIT * * * _WELL AND/OR ON-SITE SEWER PERMIT Phone Number: Location: Legal Description: ~ ~ ) U~r;''~' -~/~c~/~ Lot Size: Type of Soil__Absorption System Is: Trench: ~. Drainfield.' ~_~ Seepage Bed: __ Holding Tank: Maximum Number of Bedrooms~ Soil Rating (sq. ft/br) he Required Size of the Soil Absorption System Is: ' DEPTH LENGTH GRAVEL DEPTH <~- . WIDTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in~ feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall ~ipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK SIZE = ~_3J~l~7~^(& GALLONS * * Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED * * * Backfilling of any system without final inspection and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER 31, 1 9 8 3 * * * Z certify that: (l) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordanceS'with codes. (3) I understand, that the on-site sewer system may require enlargement if the ~esidence ~remodeled to. include.more that /3 bedroom~ /~ Signe~: ~f~- ua~e: ~ /17l 0~.1 /<'-x, ~'~ [] SOILS LOG LEGAL DESCRIPTION: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage~ Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST ~PERCO LATION TEST N --~ 10 11'- 13- 14- 15- 16- 17- 18- 20- COMMENTS WAS GROUND WATER ENCOUNTERED? ~ ~ '(~ SL O P E IF YES, AT WHAT Gross Net Depth to Net Reading Date Time Time Water Drop ~ ~o p to ~ /0 s s PERFORMED BY: ...~"~ ~ tx~/'~ ~9~'"~ PERCOLATION RATE TEST RUN BETWEEN GR~ER ANCHORAGE AREA BOROUG~ DEPA~ '~NT OF ENVIRONMENTAL qUAL 3500 TUDOR ROAD ANCHORAGE; ALASKA 99502 CASE #,, Performed For Marvin E. Stratton Legal Description: Lot3B Block This Form Reports Soils--[-6-g Date Performed 5/22/72 1 SubdiviSion upper Eagle River Estate's x Percolation Test 6 7--- 8---- 10--- Depth Feet Soil Characteris%ics ~ Brown Silty Sand with few Gravel (SM) Gray Silty Sandy Gravel (GM) with poorly graded sand seams and occasional -- cobbles. Was Ground Water Encountered? No ~ If Yes, At What Depth? r I Reading Date Gross Time Net Time Depth to N20 Net Dro~ nute Proposed Insta)'lation: Seepage Pit × Drain Field Depth Of Inlet Depth To Qotto~ Of Pit ~'~ Trench COMMENTS: 210 square feet of drainage area'is required per oeoroom. -- N ¥~st Performed By R. E. Carlis£e Data Certified By:National '£esting ~vs. Inc. Date'. ( erljf:e Drilling :og SULLIVAN WATER WELLS P.O. BOX 670272, CHUGIAK, ALASKA 9955? * TELEPHONE 65B.2759 o~vner or ~anD ~4~g~ ' aDDreSS ~_~/~ ~ ~ ~ ~ _ ~ _ -' ~ . --~-' 7~_ stat~veuoFwal'errr ~ LeGaLDescr~O~ ~(._l__d~~ ~ ~ ~r~' --' -- DATF-Slarted ... £ndcd __.~/~-f ~ DRAW DOIa'N FT. __ GaLS P£r er ___~0 mhd oF cAs,.xc, ~ n KIND¢ I FORMATION: :"rom-i '~ FI. lo._~__ Ft. _~',,~.~6__~_T-_/~/~a_~___~ From £1. Io~ Fi._ ~ ~ ~ ~ - ~- from.. FI. lo FI ,,o~/~ ~,.,o~ ,,._~,~.y ~ ~9,o,,, ~, ,o" . I F~om, no~._9~_n. W~t~n._Q4~_~ ~'c 40~ £,,,,,, F,. rrom/~l F~.to //~rl,~ ~_ From_ FI. lo / rom ~ FL Io FI. -- ' - From_ Ft. Io. FI. to_. Fl 6J4'TE/~ - £,. ,o n.. r From. _Ft. Io FI. From FI. Io Fl. From~Ft. lo~Fl~ From_ --Ft. t0. Ft. From_~_~__~_~_F/.to Ft,,. From FI. lo Ft. From FI. to, Ft. MISCL INFORMATION: PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASRA 99519-6650 ON-SITE WELL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW970101 DESIGN ENGINEER:DUMMY COMPANY OWNER NANE:WITKOFSKY WARREN & JUNE E OWNER ADDRESS:20212 EAGLE RIVER RD EAGLE RIVER, ALASKA 99577 DATE ISSUED: 5/20/97 EXPIRATION DATE: 5/20/98 PARCEL ID:05078103 LEGAL DESCRIPTION: UPPER EAGLE RIVER ESTATES BLK 1 LT 3B LOT SIZE: 47607 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorag e.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 050-781-05 1. GENERAL INFORMATION Expiration Date: ~'II°l o~' Complete legal descdpfion UPPER EAGLE RIVER ESTATES SUBDIVISION; LOT 3B, BLOCK 1 Location (site address or directions) 20212 EAGLE RIVER ROAD * EAGLE RIVER~ AK 99577 Current Property owner(s) Mailing ~ddress · Lending agency Mailing address Real Estate Agent Mailing address JUNE &: WARREN WI'rKOFSI~' Day phone 694-6048 12110 BUSINESS BLVD. STEI~6 PMB 313 * EAGLE RIVER, AK 99577 Day phone ' Day phone Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding tank Community On-site Public Sewer The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I ved[y that my invest/ga!ion, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(am) safe, functional and adequate forthe number of bedrooms and type of structure indicated herein. I further vedfy that based on the information obtained from the Municipality of Anchorege files and from my Investigation and inspection, the on-site water supply and/or wastewater disposal system is(am) in compliance with alt applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ALASKA WATER &: WASTE'WATER CONSULTANTS, INC. Phone Address 6901 DEBAER ROAD, SUITE 2B * ANCHORACE, AK 99504. Engineer's Printed Name JF_~-I-NEY A. GAYNESS, P.E. Date 337-6179 Engineer's Comments: ' In conducting this evaluation, AWWC, Inc. attempted lo provide a thorough, conscientious enginee#ng analysis cf the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results deschbed the perfonwance of the system under the conditions encountered at the b'me of the test, and separation distances measured to readily identifiable features. The operational life cf all wells and septic systems depend on the local soils condition, groundwater levels that may tTuctuate durfng the year, and the water usage of the fam~?y being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee futura per~omlance of the system, nor do they guarantee that there are no hidden defects or encroachments. At4/WC, Inc. can therefore not provide any wananty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not autho~fzed, nor wfll it confer any legal fight whatsoever. DSD SIGNATURE Approved for. ~ Disapproved. Conditional approval for bedrooms. ~ ~. pROG~~ ..- Attachments: HAA Checklist Septic System Advisory Well Flow Advisory Manitenance Agreements Supplemental Engineer's Reort Other Original Certificate Date: Municipality of Anchorage Development Services Department 61.dldlng Safety Division On-Site Water & Wastewater Program 4700 6ou~ 8ragaw St. P.O. Box 196650 Anctmmge, AK 99519-6650 (907) 343./904 HEALTH AUTHORITY APPROVAL CHECKLIST LogalDescflptlon:UPPER EAGLE RIVER t~,IATES S/Dj LOT 36~ BLOCK 1 ParnallD: A. WELL DATA Well type pmvA'rg Date completed 6/1997 Total depth 238 ft. If A, B, or C provide PW$1D~ N/A Sanitary seal (Y/N) YES Casedto 238 fl. FROM WELL LOG Date of test 6/lg97 Static water level 209 Well I~u~on 7 WATER SAMPLE RESULTS: Coliform 0 colonies/100 mi. g.p.m. Nitrate 0.204 mg./L. 050-781-03 Well Log (Y/N) Wires properly protected (Y/N) Casing height (above ground) AT INSPECTION 6/17/2002 224 ft. 7.1 g.p.m. YES YES 12+ Other bacteria 0 colonlesJ100 mi. N/A mg./L. A~sanic: . SEPTIC/HOLDING TANK DATA * FCO IN CRAWl. SPACE Tank Type/Material CONCRETE Tank size I000 gal. i Number of Compartments 1 Date of sarnple: 6/18/2002 Collected by: AKWWC, INC. Depression over tank (Y/N) NO Pumper 268 Soil raUog ~ ft'~lxIrm) UNK Foundation cleanout (Y/N) *YES Date of pumping ' 8/31;/2001 C. ADSORPTION FIELD OATA Date installed 8/~0/tg83 Length 45/UNK Date installed 1972 Cleanoute (Y/N) YES High water alarm (Y/N) N/A JR'S PUMPING TRENCH System type SEEPAGE PIT 24O Totaldepth 12/112 fl. Eff. absorption area UNK fl= Monitodngtube YES Depression over fleld NO Date of adequacy test 6/17/2002 Results (Pass/Fall) PASS For 3 bedrooms Fluid depth in absorption field before test 0 in. Water added 800 gal. New depth 42 in. Elapsed time: 190 min. Rnalfluiodepth 36 in. Absorptlon rate >= 450+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NON;' KNOWN If yes, give data - -ir..~lt.u TRENCH ONLY, NO MOA DOCUMENT. NON AVNLABLE ON St.t. FAGE PIT Width 2.5/UNK ft. - Grovel below pipe 6/UNK ft. D. UFT STATION' / *' Date galio. 'Pump on" level at. · in. ",Pump off" . High water alarm level at in. ~ ' . · . Cycles tested, Meets alarm & circuit requirements?. E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot100'+ Absorption field on lot 100'+ Public sewer main N/A Sewer/septic service line 25% On adjacent lots 100'+ On adjacent lots 100% Public sewer manhole/cleanoot Holding tank N//A N/A SEPARATION DISTANCES FROM SEPTIC/HOlDING TANK ON LOT TO:. Building foundaUon 5% Property line 5'+ Absorption field Water main N/A Water service line 10% Surface water. Wells on adjacent lots 100'+ 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Pmparty line 10'+ Building foundation. 10'+ Water s~rvice line 10'+ Surface water 100'+ Curtain drain NONE KNOWN Wells on adjacent lots I00'+ Water main N,/A Driveway, parking/vehicle storage 10'+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspec#ons and review of Municipal records that the shove systems ere in conformance with MOA HAA guidelines in effecf on this dale. Engineer's Printed, Name Date dlcPpl~L~/' ~ GARNESS HAAFee$ '7'5.°° Date of Payment Receipt Numar (~. I~01) Waiver Fee $ Date of Payment Receipt Number ,.,,....,- ~.;:, . ...~ ' I I / I '~- ~'~"- '~.~i '..: '-' ~ ' · , :~N, ..~',z'Z- ..... ...,. ~.' ' .. ~.~ 4 '~t $.-, ,~.".~- r' ~ ,, .. , .. . .. i-! '.,~--~,~,~u, ,,, -.'.'.,, ":: .... .,'...:.. i ': "' ~' ?'''; ' "" ~'~" "" I ' ': ~-:,.--"D -' '," t ";d:/.,,' ...... ~'~-' -'/' ,',' -"-' ~ .'i "; ' : --'Y~" : , I,,' " ,,: ' '~ "; '[I '('"'; ' ~ '"' ' " ' ! I ' . ' . i ' ... 'AS-BUILT · "-- .... -i ' ' I ! hereby certify that ! have'~urveyed the · ' //-~, i'~' Anchorage Recording Precinct, Al~ka, and that the . . improvements situated thereon are with/n the property l/ne$ and do not overlap ol' encroach on the property '" lytng adjacent thereto, that no lmptovementa o~ prop- ; erty lying adjacent thereto encroach on the premises In as i~dic~ted hereon. Dated at Eagle River, Alahka 1' ROBERT C. JOHNSON ~ .. SCALE: Registered Land Surveyor No.'~SO~L~ ,1'---- ,~O" Box 455, Ea Kle B/vet, Ahska , "1 . . Phone 694-2543 . '' Date: FA:'< NO. : r~r. 17 ~(~1 [t3:4~F~ PI ON (~' SITE Welding · Mechanical · Boom Truck · Fabrication Custom Prototyping In Peter~ Creek 688-3220' QUAN. EQUIP # PART/MATERIAL RECORD PRICE EA. AMOUNT DATE ~.. WORK REQUIRED HAS I RATE AMOUNT · .. TOTAL Little Bit Enterprises N O. SIGNATURE ALL CLAIMS AND RETURNED GOODS MUST BE ACCOMPANIED BY THIS BILL. GENERALPURPOS£ CUSTOMER COPY ':;B$ - [~lbL[ I!IVEP ~,-'.,;k ~UF;TItGAT[ ROAD EAGLE RIt'ER, At', SELLING STORE ACCOUNT ~ 907 ~ ~9 ~- 3527 20- ¢00C0100- t~k~ CASH CONT. I IIIIIt~iltItl IIIII IlllI IS~ItlII I I IIIII Illl IIii STORE PERSON 99577 NUMBER DATE 1151737 6/89/8002 t.~. AM Ta;: IDJt f. OUR ORDER NO. T PAGE CUSTOME{~/10 140 143~9 I;I',ITTA ELLIS 1151737-t~,0 P.O. ar TERMS o~o~,~o s~,~D U/M ITEM (~,l.( ;H ~.~{'lt ~. DESCRIPTION UNiT .... EXTENi~.D ' 7 7, L'i'~ CPC96, C. ?4LB PORTLAND CEM+NT TYPE I 7EA 10.99' '' ~6.93 TENDERED BANK ~ItRD 76.93- ~* Ih~,ttlQ~i- 0 ~)~111517 76°93 CELEBRATING 50 'FEARS OF HELPII'G ALASKANS ~HIL. D BET[ER HOMES & COMHUtlIT]ES! ~ , 658 .I ZtK CT&E ~vlronmental ~Ice. Inc. CT&E Ref.# Client Name Prolect Name~ Client Sample ID Matrix Ordered By PWSID Sample Remarks: 1023628001 All Dates/Thne~ are Alaska Stnndsrd Time AK. Water & Wastewater Consultants Inc. Prtnted Date/Tlme 06/25/2002 11:08 N/A Collected Date/Time 06118/2002 16:00 Upper 'Eagle Riv~ Est L3B Bk I Received Date/Time 06/19/2002 14:00 Drinking Water Technics! Director Stephee~.,)£de Allowable Prop A~lysis P..e~lls I~QL Uni~ Ided,,od Limi~ Date Daw Init Waters Dopartment Nitrate-N M:[.crobiology Laboratory Total Coliform 0.204 0.200 rog/l, EPA 300.0 (<10) 06/20/02 0 col/I OOmL SMIg 9222B (<l) 06/I 9/02 JDT APPLI¢'"NT FILLS OUT UPPER HAr"~,ONLY Mailing Address Zip Code Buyer Address ' Zip Code Lending Institution Phone Address Zip Code Type of Resi~nce Slngle Family Multiple Family No. of Bedroo~ Water Supply ~ Individual A~ACH WELL LOG. A well Icg is required for all wells drilled since June 1975, ~ Community For wells drilled prior to that date, give well depth (attach Icg if available). ~ Public Utility Sewer Disposal ~ Individual Year Individual Installed:_ ~ Public Utility When Connected to Public Utility: ~ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH RE~EST BEFORE ~OCESSING CAN BE INITIATED. Time Date Inspector Field Notes: Time Time D te .ate Date ~_¢.~ ~ ~_ $~'~)3 ) DATE Soils Rating Date Se er Install d Well To Absorption Area Well to Tank Well Log Received Septic Tank Size EXCAVATION ROEERT A, SHAFER WORK August 8, 1983 CIVIL ENGINEER 694-2979 Area Realty ATTENTION: Roberta Kolb P.O. Box 249 Eagle River, Alaska 99577 Dear Ms. Kolb, Reference: LOt 3B: Block-1: Upper Eagle River Estates A sewer system adequacy test was performed on the system located on the referenced property as you requested. The septic tank was Dumped and verified to have a capacity in excess of 1000 gallons. The seepage pit was charged with 800 gallons of 'f~-esh water and after a per~od of 24 hours approximately 156 gallons had percolated out of the crib. It can be concluded rom this test that the septic is adequate for the three bedroom residence located on'this property, however I regret to inform you that the seepage pit appears only to be adequate for approximately on9 bedroom.' It will be necessary for ~ou to have the absorption ~e~ ~pgraded before it can be adequate for three bedrooms. If we may be of further service, please do not hesitate to call. cc: Municipality of Anchorage Department of Health and Environmental Protection SRB 196X EAGLE RIVER, ALASKA MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION 825 L Street - Anchorage, Alaska 99501 ENVIRONMENTAL ENGINEERING DIVISION Telephone 264-4720 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed, Please altow ten (10) days for processing. HAILING ADDRESS PROPERTY RESIDENT (If different from above) PHONE PHONE 2. BUYER 3, LENDING INSTITUTION MAILING AbD~ES~ ' ' ' 4. REALTOR/AGENT MAILING ADDRESS · EGAL DESCRIPTION TREET LOCATION '~ 6. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] One [] Four [] Other [] SINGLE FAMILY [] Two [] Five [] MULTIPLE FAMILY ~ Three [] Six 7. WATER SUPPLY J~ INDIVI DUAL* * ATTACH WELL LOG. A well log is required for all wells drilled [] COMMUNITY since June 1975. For wells drilled prior to that date, give well 'E~] PUBLIC UTI LITY depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM F;~ INDIVIDUAL/ON-SITE** **If individual/on-site, give installation date If system is over two (2) years old an adequacy test is required [] PUBLIC UTI LITY by this Department, NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72~010(3/78) THIS SIDE FOR OFFICIAL USE ONLY DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR I NSPECTO R DIRECTIONS: 1. TYPE OF RESIDENCE NUMBER OF BEDROONIS [] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTi LITY Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER [] INDIVIDUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY I ~ ~ "2-. Connection Verified INSTALLER []Septic Tank or [] Holding Tank I Size: ~(~LO(~) If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AR EA MATERIAL 4, DISTANCESwELLTO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5, COMMENTS ~/APPROVED FOR 3 BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPROVED LEGAL DESCRIPTION ¢ 72-010 (Rev, 3/78) August 1, 1978 R&M No. 851559 Target Realty 1021W. 25th Avenue Anchorage, Alaska 99503 Re: Adequacy Test on Existing Sanitary Sewer System; Lot 3B, Block 1, Upper Eagle River Estates , Eagle River, Alaska Dear Mr. Bannister: Per your request of July 30, 1978, we conducted a test of the sanitary sewer system on the above described property. The septic tank had been pumped prior to the performance of the test on the seepage pit. During the test the liquid level in the crib was measured before and after the addition of 650 gallons of water. The total depth of the crib was 11.2 feet. Ail liquid levels were measured below the top of the standpipe and are summarized in the following table: Liquid Level Before Water Added Liquid Level After Water Added Total Rise in Liquid Level 5.7' 4.6' 1.1' The water level rose 13.2 inches with the addition of 650 gallons of water, indicating an acceptance rate of 49.9 gallons per inch. Twenty-four hours later the liquid level was again measured and found to be 5.4 feet. It had dropped 0.8 feet or 9.6 inches. This indicates an average effluent accept- ance rate of 479 gallons par day for the surrounding soils. If the 3 bedroom residence on the property is to house 6 people, the average load on the system can be expected to be 450 gallons per day. We can therefore conclude that the system is disposing of effluent at the adequate rate for a 3 bedroom residence. August 1, 1978 Target~Realty P~ge -2- We appreciate this opportunity to be of service to you. Please contact us if you have any questions regarding this letter or we can be of additional service to you. Very truly yours, R&M CONSULTANTS, INC. Lynne Kosikowski Staff Geologist ProJect Mahnager ¢S:LK/kky July 25., 1978 .~/No. 851559 Target Realty 1021 West 25th ~chorage, Alaska 99503 r S t 3B Block Upper Eagle River Estates Subdivision, Eagle River~ Alaska Dear Mr. Bannister: At your request of July 11, 1978~ we conducted a test of the septic system on the above described property. During the test the liquid level in the septic tank was monitored as water was added to the system. The measurements are summarized in the following table: Liquid Level Below Top Total Gallons Time of Standpipe Added 9:14 4.7 0 9:22 4.7 25 9:35 4.7 75 9:47 4.7 125 9:59 4.7 175 The meter used during the test was a Rockwell 5/8" standard water meter which had previously been calibrated by Rfsl~ Consultants, Inc. If the 3 bedroom residence on the property is to house 6'people, the average load on the system can be expected to be 450 gallons per day or .31 gallons per minute. During the test, the system accepted 175 gallons in 45 minutes. This indicates an average effluent acceptance rate of approximately 3.8 gallons per minute at the time of the test. Because the house on the lot is occupied, we assume that the leach field was at its normal degree of saturation. We can therefore conclude that the system is disposing .of effluent at an adequate rate for a 3 bedroom resi- dence. July 25, 1978 Target Realty Page -2- We appreciate this opportunity to be of service to you. Please contact us if you have %ny questions concerning this test or if we can be of additional service. ,Very truly yours, R&M CONSULTANTS, INC. Lynne Kosikowski Staff Geologist P~oj ect Manager i/MB/kah GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3500 Tudor Road, Anchorage, Alaska 99507 279-8686 Date Received~]~/25/74,~ Time of Inspection Date of Inspection 1/28/74 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES FOR VA 1. Aoproval Requested By: Stratton, Marvin ~ Address: SR BOX ]64 Eaq]e River AK 2. Prooertv Owner: Same 3. Legal Description: ..... Lot 38. Block ] 4. Location: 3 Mile E.R. Road 5. Type of Facility to be Inspecte. d: Single Number of Bedrooms: , Three (~) Wet] Data: A. Type Drilled C. Construction Standard Sewage Dtsoosal System: A. Installed. 1972 C. Septic Tank: 1. D. Seepage Pit: 1. Disposal Field: Distances: A. Well To: Phone: Phone: B. Depth ?00' , D. Bacterial Analysis ozzelnnn g.l: 2. Size 3 rings 2. Installer gelf Manufacturer Wallace Material Co~crete Total ~ength of Lines Septic Tank · Nearest Lot l,ine Foundation to Septic Tenk , Absorption Area ., Sewer Lines · Other Contamination Bo "~ Ab'~orptton Area Co Absorption Area to Nearest Lot Line Request for Approval of ~'"'vidual Sewer & Water Facilitif--i Page Two 9. Comments: Aonrov Disapproved Date Aporova] Valid for One Year From Date $.gned Greater Anchorage Area Borough, Department of Environmental Quality DIAGRA~ OF SYSTEM t certlfy that the information contained in this raquest for approval to be a true ~nd accurafie representation of fha subject sewer and water facilities located Signe~ Date