HomeMy WebLinkAboutSKYHILLS PH 2 BLK 3 LT 195kyhills
Block 3
Lot 19
#011-122-45
Municipality of Anchorage ,.t:.~
Development Services Department -~'~z~ :
Building Safety Division
On-Site Water and Wastewater Program. 4700 S, Bragaw St.
P.O. Box 196650 Anchorage. AK 99519-6650 Page of
www.cl.anchorage.ak.us (907) 34~-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: .5' ~J OOO ~.~3 PID Number: OiI _f~....zlS""
"'"~ ~)O~,.~,5~ ~ ~)~t~ ~LI~S~..I~ WastewaterSystem: [~New rlupgrade
t, ,c~. P.o~ ZZ O~-~°t {~t~¢~. kY.. .5 ABSORPTION FIELD
LEGAL DESCRIPTION O, Lo
o,.s +.. ql. ,,.
Well.~......~ [--I New D Upgrade o,~,e .,o~
,=..,,.,.,,.,.,..,,aX'~ .,.o,., ,,. c--,. ,, r-,,,,-~,--. 17-..'~'~ ,,'
GPM rtI ~'~ FL TANK
SEPARATION DISTANCES D septic [] Holding ~ ~.T.E.P. I-I Other.
Septic Absorption Lift Holding Putxr~/P6vate M~u~'tee~ C~
Tank Fie,d Station Tank Sewer tine ~ f'lC'~'~. '"~:~". ZOOO Cal.
e.--w.,, /00'+ IOo% 'oO"l- j' ~ / UFTSTATION
'~ Z~'15.5'\ ~/ ~'
,,,.-,,,- 9 ' 50' ,l 9~"
"'"'" BENCH MARK
Inspe~Uons v ~ u~ .... D~les: ~ ~ 'J~ - ~ ~ ~ ~ ~.'.~ ....... ~ .....
DevelOpment Se~jces Depadment Approval
Reviewed and approved by: ~./~. ~ Date: ~ '~/
PERMIT NO. SW000285 PAGE 2 OF 3
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650e Anchorage, Alaska 99519-6650 e Telephone: 345-4744
On-Site Wasfewaler Disposal System and/or Well Inspection Report
LECAL LOT 19, BLOCK 5, SKYHILLS S/D
P.I.D. NO. 011--122--45
NEW 2000
~E:_-:::_- - _ A__.L_T E_..R__N A_T__E ...S. i T E GALLON
· - ........ ------3 F SEPTIC TANK
,,~-,-,TH#39 MT1 ST2 ,/ WITH S.T.E.P.
MT2 ~Jc-,., ~ _..~-~---:-~ST1
-- KEYBOX A
WATERLINE
EXISTING
5 BEDROOM
HOUSE ~
SURROUNDING PROPERTIES SERVED
BY PUBLIC WATER SYSTEM.
SCALE 1' ,, 50'
PERMIT NO. ~W000285 PAC[ 5 OF 5
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650e Anchorage, Alaska 99519-6650 e Telephone: 545-4744
On-S|te Wastewater Disposal System and/or Well Inspection Report
L£CAL LOT 19, BLOCK 5, SKYHILLS S/D
P.I.D. NO. 011--122--45
--FINAL GRADE
/ ST2
86.?'--~ I 2000 GALLON
I S.T.E.P.
[_ SYSTEM
·
NO WATER FOUND
76.5' B.O.H.
'Tlr
FINAL
GRADE
MT1=83.5'
MT2=83.8'
MT MT~ =95.2'
fMT2=97.4'
7A'.0 ~ C
FCOt
46',0
FC02~ 7,0' 46,5' ---
$T1 15.0' 44,0'
ST2 24.5' 55.5' ---
MH 26.5' 52.5' ---
C01
dT1 40.0' 18.0' ---
;02
dT2 67.0' 60.0'
SR~DISTRIBUTION
PIPE = 90.8'
S~L[ = N.T.S.
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR:
· ECA, DESCRIPT,ON:
or l/d------------------~.
2
3-
4
5-
6-
7-
8
9
10
11
12
13
14-
15-
16-
17-
18-
19-
20-
Ownship, Range, Section:
SLOPE
WAS GROUND WATER
ENCOUNTERED?
De~ Io Waer kller ~ ~
ILle~i~ing? fla~
SITE PLAN
I
N
Cross Net Depth to Net
Reading Date Time Time Water Drop
~, " Y /,'--
"/ ~ "'"" I
PERCOLATION RATE ~)-~ (msnutes~nch) PERC HOLE DIAMETER
TEST RUN BETWEEN ~' FTAND '~* FT /~r4f
COMMENTS
W,T~.'~'.~:~.~"~*'----~-- -- -- '--'N EFFECT ON TH,S °ATE.
ACCORDANCE
72-008 (Rev. 4/85)
CERTIFY THAT THIS TI[ST WAS PERFORMED IN
~1, ~.lop
~~8/~0/2001 16:13 9872480851~
Pa~g~lt
M~DO~' S #76~2
PAGE
MUNICIPALITY OF ANCItORAGE -- BUILDING SAFETY DIVISION
4700 SOUTH BRAGAW STI~EF~T, ANCHORAGE, ALASKA.
INSP£CTIONS: g'~:e: (907)$4J..~$00 Far: (90D 249-7777 INFORMATION: (907t $45-~211
t~o~: PRIM!~¥ELeC'rPJC ~n~tr~z~- 00-0857
AOD/t. rSS: a201 I-~AVENI.Y CIR DAZE: ~/23/01
PItONP;#1: $63-7985
LO~ 19 ~LOCK: 3 $~BDIFISlON:
COMMENT~ B6B ......
INIVPECTIOA? E]cctrical Final
bo non-complitace ob~r~. [] Do not conceal ~t~l r~-in~ed~d, r'] c.o. ~,rovrd.
Con*~cfon s ~m~ial u ~l~ed b ek~w. ~ WIll re-examine I~ nent bt~tx:fion ["l
COMMEI~Ia': p. eln.~ec~? ~
~ CORREc:'tzOIVS,tRE MADE, PLF. A,¥E CALL FOR INSPE~TJOIV
DO IVOT REMOV~ TIlls NOTICE.
2~76
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On-Site Services Program
825 L Street, Room 502
P.O. Box 196650. Anchorage, AK 99519-6650
(907) 343.4744
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Date Issued: Aug 07, 2000
Expiration Date: Aug 07, 2001
Permit Number: SW000283
Legal Description: SKYHILLS PHASE 2 BLK 3 LT 19
Design Engineer. 0003 S & S Engineering
Owner Name: Duane Clausen
OwnerAddress: PO Box 220744
Anchorage, AK 99522-
Parcel ID: 011-122-45
Site Address:
Lot Size: 40087 SQ. FT.
Total Bedrooms: 5 Permit Bedrooms: 5
This permit is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be In accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either. A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
A PERCOLATION TEST SHALL BE PERFORMED DURING CONSTRUCTION TO CONFIRM THE ABSORPTION
FIELD SOILS OUTSIDE THE 30 FOOT RADIUS OF TEST HOLE #39.
Received By:
Issued By:
Date:
Date:
.July 20, 2000
ROBERT C. COWAN, P.E.
CML ENGINEERS
(907) 694-2979
FAX (907) 694-1211
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
P.O. Box 196650
Anchorage, AK. 99519
REFERENCE: Lot 19, Block 3, Skyhills S/D
It is requested that you issue a permit to install a septic system ·, , · to serve the
proposed five bedroom dwelling on the referenced property.
Two test holes were excavated and percolation tests were performed. The approximate
location ofthe test holes are located on the attached site plan. At the time of excavation on
8/7/98 water was found at 16 feet. After seven days of ground water monitoring water
was found at 16 feet in test hole #38 and test hole #39 was found to be dry.
We do not anticipate any adverse effects on neighboring wells, septic systems, reserve
areas or drainage patterns by the installation of the proposed septic system. The
construction of this system will not prevent any future development on any of the adjacent
properties.
Ifyou require additional information, please contact us.
Sincerely,
Robert C. Cowan, P.E.
RCC/jhm
Enclosure
17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER. ALASKA 99577
SITE PLAN
DESIGN
0
c~DO
50'
SITE PLAN DETAIL 1" = 30'
Zm
--.t rtl
Z
II-.
0
0 rla
0
-0
0
"O
0
I-q
C]
m
Z
0
'T
907248085~
HCDOH~LD'S #7602
PAGE 02
Identclpellly Of Ntche~ .
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 ~' SI~L Anchorage, ~ka ~2~
SOILS LOG -- PERC0~TION TEST
10-
12 -
1S.
16-
17-
18-
.lg
PliRCOL,ATION RATE ~ (m,nMekmChl PERC HOLE DIAMETER
vao pre.soaked Prior 't,o teatLnG.
~etl~m~- ~iehaeX E. Ande so
~1~ ~/IT~ A/eL ~TATIC AJ~O MUN~CtpAI. (~UIC)EUNE$ IN EFFECT ON THIS DATE. ~AT)~D' ,
9072488850 HCDOHALD'S #7602 PAGE
Municipality of An~ra~.
DEPARTMENT OF HEALTH & HUMAN SERVICES
~25 'L" ~lr~. Anchorage. ~aska ~50~
SOILS LOG ~ PERCO~TION TEST
· ER~C~EO ~OR: L H Conatruct~on, Ina. OATe
. J ~ ~nshlp. Range. Se~on:
4-
S-
E-
7-
8-
9-
10-
11-
12
13
16
17
18
'.19-
20-
II Itttl
I I I Jill
I I IIIj.~l
I I lll~l
WAS GROUND WATER
ENCOUNTEREO?
COMm~rs..9erc cavlt~ VSS
PERCOLATION "ATE '~"~'~ [m,nutes,'mc., PER¢ HOg[ DI~ETER .~"
TEST RUN 8ETWEEN -- ~ FT AND -- ~ IT
~resoa~e~ prlor to
PERFORMED BY'-- -~/~-- - I CERTIFY 'THAT THIS TEST WAS P~RFORMED IN
F,~chae~ E. Andereon
ACCORD~CE WITH ALL ~TAT[ AND MUNI~P~ GUIOEUNES IN EFFECT ON THIS DATE, DAT[ .
ROBERT C. COWAN, P.E.
CML ENGINEERS
(907) 694-297'9
FAX (907) 694-1211
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MATERIAL SPECIFICATIONS
REFERENCE: Lot 19, Block 3, Slcyhills S/D
July 20, 2000
GENERAL:
The scope of this project includes the installation of a 1500 gallon septic tank
and a new trench to serve the proposed five bedroom residence located on the
referenced property.
Construction shall be in accordance with the approved site plan and design
drawings, Municipal permit with any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal Regulations.
The con~xactor shall be responsible for obtaining any necessary underground
utility locates.
Unless specifically agreed otherwise, the property owner shall be responsible
for final grading areas subsequently depressed from soil settling.
Contractors installing wastewater disposal systems must be certified by the
Municipal Health Department for system installations. Owners installing
their own systems must also receive prior approval from the Municipal Health
Department.
SEPTIC TANK INSTALLATION:
o
A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" cleanouts for pumping access.
Thc septic tank shall be sufficiently bedded to prevent settling or shifting of
the tank.
17034 NORTH EAGLE RIVER LOOP , SUffE 204 · EAGLE RIVER. ALASKA 99577
Page 2
Lot 19, Block 3, Skyhlll. $/D #1
July 20, 2000
3. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade.
Septic tanks installed with less than 4 ft. of cover shall be insulated.
A foundation cleanout shall be installed one to four feet from the building foundation. In
the line between the tank and the leachfield there shall be two adjacent cleanouts (unless
an effluent pumping system exists within the septic tank). These cleanouts shall be
located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line,
shall be to clean toward the leachfield. The second cleanout shall be to clean toward the
septic tank.
Final grading over the septic tank shall be such that a positive slope exists away from the
septic tank.
ABSORPTION TRENCH/DRAINFIELD INSTALLATION:
1. Excavate the proposed trench to the dimensions shown on the design. The bottom of the
excavation shall be within 2 inches of level. If the sidewalls of the excavation become
smeared, they must be raked or scratched (rafted-up) before gravel (sewer rock)
placement.
2. Once the gravel is installed, thc distribution pipe is to be installed level with the
perforations faced downward. Gravel is then to be placed over thc distribution pipe to
provide a minimum of 2 inches of cover over the pipe.
3. A silt barrier must be installed between the final gravel layer and the native soil backfill.
Ensure the silt barrier covers the entire gravel surface before placing backfill.
Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations
shown on the design, and extend a minimum of 12 inches above final grade. The portion
ofthe monitoring tube extending through the gravel shall be perforated from the bottom of
the trench to the invert of the distribution pipe. This is equivalent to the effective depth of
the gravel as noted on the design.
Backfill over the final gravel layer must not be less than twenty-four (24) inches.
Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The
finish grade over the trench must be mounded to prevent the formation of a depression
after settling.
Page 3
Lot 19, Block 3, Skyhllls $/D #1
July 20, 2000
MINIMUM MATERIAL SPECIFICATIONS:
1. Any septic tank proposed for installation must be constructed by a Municipal approved
septic tank manufacturer.
2. The following pipe materials arc approved for use in septic system installations in the
Municipality of Anchorage:
TW, e of Pipe ~cr rotated ~olid
Cast Iron Yes Yes
ASTM D3034 (PVC) Yes Yes
ASTM F810 (HDPE) Yes No
ASTM D2662 (ABS) Yes Yes
Use of a type of pipe other than listed above must be approved by the inspecting engineer.
Insulation shall be at least 2" thick ex~'uded direct burial polystyrene (Dow Chemical
Company Styrofoam HI or equal).
Septic tank inlets and outlets shall be fitted with watertight couplings (Caul&r, Femco, or
equal).
A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed
between the final leachfield gravel layer and the native soil backfill.
All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3%
passing the #200 sieve.
When sand is being used as a filter material, its gradation specifications must conform to
current M.O.A. or D.E.C. requirements, which ever requirement applies.
INSPECTIONS:
Typically there will be a minimum of three (3) inspections required during the installation of the
wastewater disposal system. These inspections will occur as follows:
· · page 4
Lot tg, Block 3, Skyhllls $/D #t
July 20, 2000
1. The first inspection must be conducted after the excavation of ditches, pits,
trenches, or beds and before the installation of any gray.el. A septic tank may be
set in place, but may not be backfilled before this inspection.
silt barrier,
2. The second mspectlo must be conducted after the placement of the
gravel, distribution lines, standpipes, cleanouts, and insulation, but before the
placement of anY other backfill.
3. The final inspection is to occur upon final grading of the property.
Often there will be more than these 3 inspections required. Especially with the installation of
multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer
is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-
construction meeting will take place on-site. The inspecting engineer will not coordinate, direct
or control in any way the contractors activities.
The owner shall contract with the contractor to perform the work outlined in these specifications
and plans and in accordance with the attached M.O.A. permit. There will be no contractual
arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be
the owner's representative and will inspect the work as stated above to document the contractors
activities. Final acceptance of the contractors work rests with the owner and the M.O.A.
S & S Engineering shall have no liability to the owner or to others for acts or omissions of the
contractor or any other persons performing work on this project or the failure of the contractor to
carry out the work in accordance with these construction documents. S & S Engineering's
inspecting engineer will not be responsible for the cons .t.mctio.n means, methods, techniques,
~netdent P 'J ·
sequence, procedures or the safety precautions' ' to th~s ro ect
- CONTRACTOR / INSTALLER