HomeMy WebLinkAboutBRUIN PARK BLK 4 LT 21Bruin Park Block 4 Lot 21 #016-101-17  Municipality of Anchorage Development Services Department ~..-_-: Building Safety D;vlslon On-Site Water & Wastewater Program. 4700 South Bragaw SL P.O. Box 196650 Anchorage. AK 99519-6650 www.cl.anchorage.alcus (907) 343-7904 Poge 1 On-Site Waetewater Disposal System and/or Well Inspection Report Permit Numbec SW000297 PID Numbec 016-101-17 N°m':BERNARD & EILEEN SOMMERVILLE Wastewater System: [3 New · Upgrode ,~d.,,: ABSORPTION FIELD 11140 POLAR DRIVE No. of Bedrooms: Ph°n':(907) 344--8199 4 · Deep Trench f'l Shollow Trench f't Bed D Mound LEGAL DESCRIPTION 0.6 ~. lO.44 UAX. 21 4 BRUIN PARK 5.88 MAX. r~ 6.5 - - - SEE DRAWINGS r~ 84 WELL: [3 New [] Upgrede 2.5 r~ 1 G r~ r~ 1092 ~... D 3034/ F-810 r~ JASON WOOD 6/2/01 ~, ,~ n TANK SEPARATION DISTANCES ·s.,~; ~,o,d~n~ ,~S.T.~,. ~= s, puc ~o~uon L~t ,~d;,; ~,,,m~,~ ANCHORAGE TANK 1250 w~ 100'+ 100'+ - - 25'+ STEEL 2 s~,o=o wo~,, lOO'.lOO'. - - - LIFT STATION Curtain Drain · NONE KNOW ~ ~ ' I Remarks: * 1 FOOT LOT UNE WAIVER GRANTED BENCH MARK WITH PERMIT (WE000058). BOTTOM OF SIDING ON THE NORTHWESTERN HOUSE CORNER. -VERBAL AUTHORIZATION FROM JEFF POET 100.00 2nd 6/2/ol'T~'~T/~" ~ Department of Health.and.~Human Servl?.es.,~.pproval ,~?o,_...~ ......... . R~viewed and approved by: _/?-._ .~/~__~.../ /~/* /)~'¢"/~ Dote: ?~/~' O / AS BUILT DRAWING pEeun NUUS~: __ 016 -- 10 ! -- 17 SW000297 ~'~"~/ _ .,, ' . ,R~W,6/15/2001ay: J.W.M. ALASKA WATER & ~STEWATER ~ ' CONSULTANTS, INC.~ 1 # = 40' BERNARD & EILEEN SOMMERVILLE (907) 544-8199 2 OF 5 BRUIN PARK SUBDIVISION, LOT 21, BLOCK 4 AS-BUILT DRAWING OF SEPTIC SYSTEM UPGRADE ST1 28.5 15.9 5T2 36.2 18.4 DBL1 39.7 20.5 DBL2 40.8 21.1 ~01 43.5 23.3 MT1 44.9 24.4 C D I C02 34.5 17,.3 MT2 ;55.8 17.9 AS BUILT DRAWING ~Rur~ NUU~: ~ O16--101 --17 SW000297 /--FINAL GRADE = 98.40 /--2' INSULATION / / PER EXOAVATOR TOP OF TANK AT---~ J= J -- / /--TOP OF TANK AT INLET = 95.21~ ~__.____~~. ~OUll.~ - 95.15 ~ ~--- / / ' SEPTIC TANK INV[RT OF' BUNG AT AT INLET ~ 94.64 OUTLET - 94.58 ALASKA WATER & WASTE~TER~,a.~.''w'M' f~.""~.~t' [ '"-.Z'~ CONSULTANTS, INC. ~ N.T.S. ~' .... !'J/al i ............... , '~ ~" ~'~'~"~ BERNARD & EILEEN SOMMERVILLE (907) 544-8199 BRUIN PARK SUBDIVISION. LOT 21 BLOCK 4 AS-BUILT DRAWING OF SEPTIC SYSTEM UPGRADE . ............. PERFORMED FOR: BER~D CONnEXiON HOLE (r ORe,CS ITEST HOLE ~2~ SH OH SC DEPTH TO DATE GROUNDWATER D~ 6/2/01 11 DATE RE. lNG CLOCK NET TIME WATER LEVEL NET DroP TIHE (MIN~ES) RE.lNG (INCHES) 12 ~3 c~ (so~E S~L~ ~O~~ 19 PERCO~TION ~TE .(HIN.IINCH) PERC. H~E DIA. 6' .(INCHES) TEST R~ BETWEEN FT. ~D FT. 2 COHHENTS: W~ATER I, JEF~ A. G~NESS, CER~ ~T ~IS W~ P~FORMED PERFORMED BY A~ WATER IN ACCORD~CE WI~ ~L ~A~ MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Aug 15, 2000 Expiration Date: Aug 15, 2001 Permit Number: SW000297 Legal Description: BRUIN PARK BLK 4 LT 21 Design Engineer: 0041 AK Water & Wastewater Consultant Owner Name: Bernard & Eileen Sommerville Owner Address: 11140 Polar Dr. Anchorage, AK 99516-1354 ParcellD: 016-101-17 Site Address: 011140 POLAR DR Lot Size: 24000 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage A~I construction must be in accordance with: 1. The attached approved design. 2. A~I requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and dosed on the same day. B. Covered, sealed, and heated to prevent freezing. Municipality of Aritho.rage George P. Wuerch, P.O. Box 196650 Anchorage, Alaska 99519-6650 Mayor http://~w.cL anchorage.ak.us August 18, 2000 JeffGamess Alaska Water & Wastewater Consultants, Inc. 6901 Debarr Road, Suite 2-B Anchorage, AK 99504 Subject: Waiver Request for Bruin Park, Lot 21, Block 4 Waiver Request #WR000058 Parcel ID #016-101-17 SW000297 Dear Mr. Gamess: Your request for a waiver of the required 10 feet horizontal separation from the on-site wastewater disposal system to property line has been approved. The approved separation distance is 1.0 foot. This waiver approval applies to the existing on-sitewastewaterdisposal system to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-4744. Sincerely, Civil Engineer On-Site Water Quality Program MUNICIPALITY OF ANCHORAGE Department of Health & Human Services On-Site Services Waiver Review Worksheet WR#: WR000058 PID~: 016-101-17 Date Received: August t6~ 2000 Legal Description: Bruin Park~ Lot 21~ Block 4 Engineec Alaska Water & Westewater Consultants~ Inc. 6901 Debarr Rosd~ Suits 2-B~ Anchorage~ AK 99504 Applicant: Bernard & EIlesn Sommervllle Waiver Requested: I foot lot-line waiver. Cdtaria: 1. Geology A. Watar Table B. Soil So,'ption C. Permeability D. Water Table Gradient E. Horizontal Separation Points: Total: 2. Special Conditions: 3. Other:. Permil~: SW000297 Waiver is Granted: ,X/ waiver is not Granted: Llst Conditions or Reasons for above: v<'£E' ~',4,/~'/,4/E~'~'_ ~_~' J. Z'/'7'~.'~ ,~'nount: $115.00 By: Nam~ of Reviewer Date Paid: .~116100 ALASKA WATER & wAsTEwATER CONSULTANTS, INC. August $, 2000 Municipality of Anchorage Department ofItealth & Human Services Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchomge, .Al~qka 99519-6650 Ref: Proposed Septic System Design for Lot 21, Block 4; Bruin Park S/D To whom it may concern: The existing 4 bedroom house is served by a private well and septic system. A test hole was excavated on the property where the proposed septic system upgrade will be located. The proposed septic system will be designed around the 30 foot radius of this test hole and a second test hole which will be excavated during construction. We are proposing that a 1250 gallon septic tank and a deep trench type dminfield be installed. Comments regarding the proposed design are summarized as follows: 1. SOILS: Attached is are 2 mil logs which show the soil pmfde, the groundwater monitoring, and the percolation test results. Test hole #1 was excavated just northwest of the house. Below the organics was a OM/GW layer to a depth of 11.5 feet which transitions to a SM layer to 16.75 feet (bottom of test hole). A percolation test was performed between 7.0 feet and 7.5 feet and found the rate to be 24 minute/ineE Another test hole was excavated on the lot to the south which confirmed that there are no bedrock concerns. Groundwater was not encountered during the excavation of the test holes. We are proposing that a confa'mation test hole be excavated during the installation of the septic system. 2. TRENCH DESIGN: a. Percolation Rate: 24 minutdineh b. Allowable Application Rate: 0.6 gallon/day/fl2 c. Number of Bedrooms: 4 d. D,e.s!gn Flow: 600 gallons per day _ e. Minimum Absorptinn Area: 1000 ft2 f. Maximum depth: 10.5 ft. g. Effective Depth: 6 ft. h. grdth: 2.5 ft. i. Length: 84 ft. k. Effective absorption area -- 1008 ft2 6901 Debarr Road, Suite 2B * Anchorage, AK 99504 Ph: (907)337-6179 * Fax: (907)338-3246 * Website: akwwc.com 3. SURFACE WATERS: Tberc are no surface waters within 100 feet of thc proposed upgrade. 4. TOPOGRAPItY: We are requesting a waiver for separation distances to slopes greater than 25 percent. We are proposing a trench to be greater than 35 feet from a slope greater than 25 percent. This slope is naturally vegetated and we foresee no chance of sewage daylighting. 5. LOT LINE WAIVER: We are requesting a I foot lot line waiver to the northem lot line. Lot 22, block 4 is undeveloped and will not be impacted by this encroachment. I am unaware of any adverse impacts this installation would have on adjacent wells or septic systema. If you have any questions, please contact us at 337-6179. Thank you for your assistance. Presi~e~~ NOTE: Attached is a site plan drawing, a design drawing, t~ soils logs, and a 7 page construction specification letter which are all part of the design package for this septic system. 6901 Debarr Road, Suite 2B * Anchorage, AK 99504 Ph: (907)337-6179 * Fax: (907)338-3246 * Website: akwwc.com ~ ......... "~ 8/2/2000 BERNARD · EILEEN SOMMERVIL~ (907) 344-8199 2 OF 2 , BRUIN PARK SUBDIVISION, LOT 21, BLOCK 4 " DESIGN DRAWING FOR SEPTIC SYSTEM UPGRADE ! ~ 2 F2 ~./'-,, "--~,_X-77 / / ~ "~ 8/2/2000 ~~ ~TER & WASTEWA~R J.w.~. CONSULT~TS, lNG SOMMERSVILLE (907) 344-8199 1 OF 2 LOT 2~, BLOCK 4, BRUIN PARK SUBDIVISIOH SIT~ P~H FOR SEPTIC SYST[M pHONE (907) .157-5179 · FAX (907) 358-~24E ISOIL LOG-- PERCOLA,.TION TESTI LEGAL DESCRIPTION: BRUIN PARK SUBDMSION. LOT 21, BLOCK 4 PERFORMED FOR: BERNARD ac E]L£EN SOMMERV1LLE DATE P£RF'ORM]:'D: 7/15,/2000 TEST HOLE #1 SM GP GM GC I ORG OL MH DEPTH TO DATE ;ROUNDWATEI; oRy 7/15/oo DRY 7/1 DRY 7/22/00 DATE READING CLOCK NET TIME WATER LEVEL NET DROP TIME (MINUTES) READING (INCHES) 7/18/00 I 2:45 -- 5' __ 2 R:15 30 MIN. 4 5/8' 1 3/8' 3 3:15 -- 6" 4 3:45 30 MIN. 4 3/4' 1 I/4' 5 3:45 -- 6' 6 4:15 30 MIN. 4 3/4' 1 1/4' PERCOL.ATION RATE 24 .(MIN./INCH) PERC. HOLE DIA. 6' (INCHES) TEST RUN BETWEEN 7.0 FT. 7.5 FT. COMMENTS: PERFORUI-:.D BY ALASKA WATER &: WASTE'WATER I, THIS WAS PERFORI IN ACCORDANCE W[I"H ALL DATE. DATE: , CERTIFY THAT GUIDEUNES IN EFFECT ON THIS ALAS~ WATI~ & WASTEWATER CONSULTANTS, INC. ~9o~ oEa~ ~, su~ ~a · ~o~, ~. ~ ~...~ ~"~.~. ISOIL LOG - PERCO~TION TESTI ~L DESCRI~ION: BRUIN P~K SUBDMSION; ~ ~0. BL~K 4 p~o~u~ ~o~: ~o. ~oo~ ~~ '~ ~ .:~ ~ ~7'"~' ~A~ P~,~o,~: ././~ooo ~0~,~.... r [1'*~....'~¢~ ITEST HOLE ~2I  GW ~ GC SW HH · ' , ~ CH SC DE~H TO DATE ' D~ 4/~4/oo g~ 4J27JO0 B~N P~K S~ 11 DATE R~ING ~K ~ TIHE WATER ~L N~ TIHE (HI~ES) ~ING (I~HES) 12 4/17J00 PERC. HO~ W~ PROOFED 4+ HOURS PRIOR TO ~NG 13 1 3:44 -- 6= -- 2 4:14 30 3 3/8' 2 5/8" ~ SP/SM ~ ~:~ - s' - 4 4:48 30 3 3/4' 2 1/4' 5 4:49 - 6- - 16 6 5:19 30 3 3/4' 2 1/4" lO ~RC~TI~ ~ 13.3 ~IN./IN~) ~. H~ DI~ ~(I~ES) 2 TEST ~ B~EN 7.0 ~. ~ 7~ C~HE~S: P~FORM~ ~ ~ WAT~ · W~i~WA~R. I, JE~ ~ ~NESS, C~ T~T ~IS W~ P~D IN ~CORD~CE W~H ~ ~A~ ~D MUNICIPAL GUIDEUNES IN ~E~ ON MUNICIPALITY OF Development Services Department On -Site Water & Wastewater Section - - Parcel I.D. 016-101-17 Certificate of On -Site Systems Approval 1. GENERAL INFORMATION Phone: 907-343-7904 Fax: 907-343-7997 Expiration Date: lQ doC r� Complete legal description Bruin Park, Block 4, Lot 21 Location (site address) 11140 Polar Dr. Anchorage, AK 99516 Current property owner(s) Darryl and Joyce Matthews Day phone 602-6808 Mailing address 11140 Polar Dr. Anchorage, AK 99516 Real estate agent Day phone (907) 602-6808 2. TYPE OF DWELLING: [D Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well Fx� Private Septic' R Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ J'-Jb/ 1112 .� Date of Payment (o L15!%d U Receipt Number 63tiJ7ob COSA# 126112 57S Waiver Fee $ Date of Payment Receipt Number Waiver # 6. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Forge Engineering Phone 907-522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage AK 99503 Engineer's Printed Name Michael E. Anderson, P.E. Date 6/12/2020 6. DSD SIGNATURE ISystem #1 Approved for 4 System #2 Approved for Disapproved Conditional approval for bedrooms bedrooms bedrooms, with the following stipulations: WATER ANn 661, By: Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory . Well Flow Advisory Other COSA Checklist blue sheet r Legal Description: Bruin Park, Block 4, Lot 21 Parcel ID: 016-101-17 If more than 1 septic system on lot: COSA Checklist # of Structure served by this system A. WELL DATA ❑ Well log is filed with Onsite (or attached) Well production at time of test 5.4 gpm Date drilled Water storage tank volume gallons Total depth 144 ft Well disinfected for coliform test? ❑ Yes ❑ No Cased to 40+ ft ❑ Coliform bacteria is Negative ❑ Sanitary seal is functioning correctly Nitrate mg/L ❑ Nitrate less than MRL (ND) ❑ Wires are properly protected Arsenic ug/L ❑ Arsenic less than MRL (ND) Casing height (above ground) 12" in. Collected by FORGE ENGINEERING Date of flow test for COSA 7/31/19 Date of Sample 6/12/20 Static water level at beginning of test 67 ft. Comments No well log on file. Previous COSA in 2004 notes that it was probed to 144' and cased to 40+ B. TANK DATA Age of tank(s) 18 years Tank type/material Septic/Steel Measured operating fluid level in septic tank 51 ❑ Standpipes/foundation cleanout per record drawing Date of pumping 6/18/20 Northland Pumping Service D. ABSORPTION FIELD DATA Deep Trench Which system tested (date installed) 6/15/2001 ❑ ALL standpipes present per record drawing Total measured depth from grade 11.2 ft (max) Measured depth to pipe invert from grade 4.1 ft (min) ❑ N/A — pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective Al Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Comments/Deficiencies: COSA Checklist yellow sheet C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Comments: Adequacy test date 7/31/19 Results ❑✓ Pass For 4 bedrooms Fluid depth prior to test 43 in Water added 950 gal New depth 58 in Elapsed time 1440 min Final fluid depth 45 in Absorption rate '600 gpd Any rejuvenation treatment (past 12 months) If yes, enter date E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' F71 Yes Community Sewer Manhole/Cleanout > 100' Q Yes if No ft Q Yes if No ft Neighboring Tank > 100' 0 Yes if No ft Private Sewer/Septic Line > 25' 0 Yes if No ft Absorption Field on Lot > 100' 0 Yes if No ft Holding Tank > 100' 0 Yes if No ft Neighboring Absorption Fields > 100' Q Yes if No ft Water Main > 10' Animal Containment > 50' 0 Yes if No ft ✓0 Yes if No ft ✓Q Yes if No ft Water Service Line > 10' ✓0 Yes if No Manure/Animal Excreta Storage > 100' If septic tank is under driveway comment below Community Sewer Main > 75' 0 Yes if No ft Fv� Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' F71 Yes if No ft Surface Water > 100' Q Yes if No ft Property Line > 5' ✓0 Yes if No ft Wells on Adjacent Lots: 0 Absorption Field > 5' 0 Yes if No ft Private Wells > 100' Q Yes if No ft Water Main > 10' ✓0 Yes if No ft Community Wells > 200' ✓Q Yes if No ft Water Service Line > 10' ✓0 Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' 0 Yes if No ft If absorption field is under driveway comment below Property Line > 10' ❑ Yes if No ft Wells on Adjacent Lots: Water Main > 10' 0 Yes if No ft Private Wells > 100' Yes if No ft Water Service Line > 10' 0 Yes if No ft Community Wells > 200' R Yes if No ft Surface Water > 100' ✓0 Yes if No ft F. ENGINEER'S COMMENTS See Waiver WR000058. G. ENGINEER'S CERTIFICATION l certify that l have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet CSF �t oo 49th +`} 0.�. .... ....0 nnu...n.............. = MICHAEL E. ANDERSON No. CE -4381 7/2/20 +•. 71 � C ................. �0