Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
MARGUERITE HILLS LT 1A-3
Onsite File .� Z�l ! ��Q►7 r 'USPUWA%WW Ah'] Municipality of Anchorage Community Development Department Page 1 of 3 On -Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP ) r �" 3 d PID Number: 020-281-29 ❑ New ❑✓ Upgrade Name: Redhawk Development LLC ABSORPTION FIELD ❑ Deep Trench 2 Shallow Trench ❑ Bed ❑ Mound Address P.O. Box 10859 Zephyr Cove, NV 89448 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 1.2 GPD/SF 2.3 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade - 1.8 Ft. Gravel depth beneath pipe •5 Ft. Subdivision Block Lot Marguerite Hills 1A-3 Fill added above original grade 1.5-2 Ft. Gravel length 100 Ft. Township Range Section Gravel width 5Ft. Beds: Number of Lines Distance between lines I Ft. SEPARATION DISTANCES To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station Tank Line 500 Flz One Ft. Well >100' >100' >100' >75' >25' TANK +❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank - Existing Capacity I 1,50OGal. Surface Water >100' >100' >100' >100' Material Steel Number of compartments Two Lot Line >5' >10' N/A N/A NA Foundation >5' >10' NIA NIA LIFT STATION Manufacturer Capacity Gal. Curtain Drain None Noted Remarks Pump on level at in. Pump off level at in. High water alarm at in. Pump make and model Electrical Inspections performed by PIPE MATERIAL Housetotank D3034 Tank to D3034 drainfield Installer Dean Construction Drainfield F810 CO/MT D3034 Inspector MEA BENCH MARK (Assumed elevation) 100.Oft Inspection .� 612/15 6/3/15 Location and description dates: 2"' Upper Deck Southeast Corner. e 6/30/15 4'" COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL IIS5 0 . P� .........,910 � .• Conditional Approval: Date Gj�• AV T�1+ 49 * t0 ... .. ... ....0 %........... ...... ............. �MICHAEt E. ANDERSON �•�? f.� CF -4381 Approved GC/` Date Inspection Report-1-1-12'06`- i Municipality DEVEOPMENT SEF 4700 Elmore Road Anchorage, Permit Number: OSP141530 PID NO.:020-161-2B i 7 r ; I 1 I I I / a I E 1 I f II I I I II I II I LEGEND S1 — Septic Vent CO — Clean Out M1 — Monitor Tube TH — Test Hole '1 FCO — Foundation Cleanout I 1 1 1 1 I 1 1 1 1 1 1 1 1 1 ALTERNATE SITE: Advantex Treatment System w/30' Long by 5 Wide by No Effective '1 11 Depth Absorption Trench. `I �I Application Rate 4 1 � GPD/SF. 1 1 1 \ \ \ 1 1 I , 1 , 1 \ 1 1 I I I I ._______________I__ I I 9-6655 - 343-7904 \ \\ Page 2 of 3 \ \ \ \ \ \ \ \ \ ____C-_______-- \ \ \ �0 _ q i g TH3 \\ ® 1 S1 457-595_. __... �`. _-_ _. _ 32 56 3' 69.9' C4 625' 75.5' \\ Alternate \ ® TH2 M 172.4'.178.W Site T \ TH7 M1 67.E 79.7.' TH4 FSV M2 1167AJ1711 \ - ® TH6 1A-3 \ 2__ MARGUERITE HILLS PLAN AS BUILT SCALE 1' = 50' 10'T&EEsmt ® TH6 *q' OF 11 • �.�``P�E. OF 1141% i off.;• .. 49th :..::...................:.... :: MICHAEL , E. ANDERSON ;r I% Nn. FF -43x1. Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP141530 U � F 98.7 N �N UU 1,500 Gallon Septic Tank PID NO.:020-161-28 PROFILE AS -BUILT - No Scale .3 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: Marguerite H111S, Lot 1A-3 PERFORMED FOR: Dave MathSOn DATE: 6/1/15 PROJECT No.: PARCEL ID#: TECHNICIAN: MEA DEPTH TEST HOLE 7 (feet) 1111111 OL/OG 2 3 4 GM/SM 5 SILTY GRAVEL WITH SAND 6 7 8 9 10- 11- 12--n-1--- 0 11 12 Bedrock 13 1_111 1 SLOPE WAS GROUND WATER ENCO NO IF YES Q WH DEPTH OF WATER AFTER MO DATE OF MO 49th AEL E. ANDERSON No. CE -4381 e k 9 UNTFRED? -- ATDEPTH? O MTORING: O NITORING: It - GROSS TIME NET TIME DEPTH TO NET DROP DATE READING (MINUTES) (MINUTES) WATER (INCHES) (INCHES) 11-28 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 7:42 0.6311 2 8:12 30 8.5011 7.8711 3 8:13 0.75" 4 8:43 30 8.6311 7.8811 5 8:44 0.6311 6 9:14 30 8.50t1 7.8711 PERCOLATION RATE:: 3_8 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4 FT. and-5—FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 7-2-15 PERCOLATION RATE:: 3_8 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4 FT. and-5—FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 7-2-15 MUNICIPALITY OF ANCHORAGE - DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: Marguerite Hills, Lot 1A-3 PERFORMED FOR: Dave Mattison DATE: 6/1/15 PROJECT No.: PARCEL ID#: TECHNICIAN: MEA DEPTH (feet) TEST HOLE 8 -------------� 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 OL/OG GM/SM SILTY GRAVEL WITH SAND Bedrock 49th _ /�.• MICHAEL E. ANDERSON No READING WAS GROUND WATER ENCOUNTERED? NET TIME (MINUTES) DEPTH To WATER (INCHES) IF YES @ WHAT DEPTH!. --0 11-28 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 10:08 DEPTH OF WATER AFTER MONITORING: - O DATE OF MONITORING: 2 10:38 DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER (INCHES) NET DROP (INCHES) 11-28 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 10:08 1.25" 2 10:38 30 9.50" 8.25' 3 10:39 1.00" 4 11:09 30 9.25" 8.25" 5 11:10 1.25" 6 11:40 30 9.50" 8.25" PERCOLATION RATE:: 36 (MIN/INCH) PERC. HOLE DIA--L—(INCHES) TEST RUN BETWEEN: 4 FT. and-5—FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP141530 Tax Code Number: 02016128000 Work Type: Septic Renewal Permit Effective Dates: January 07, 2015 to January 07, 2016 Design Engineer: ANDERSON ENGINEERING Subdivision: MARGUERITE HILLS Site Legal Address: MARGUERITE HILLS LT 1A-3 G:3440 Owner/Address: REDHAWK DEVELOPMENT AK LAND LLC PO BOX 10859 ZEPHER COVE NV 894480859 Site Mailing Address: 7670 BIG MOUNTAIN DR, Anchorage Lot Size in Sq Ft: 391349 Total Bedrooms: '6'q This permit is for the construction of: Y Disposal Field N Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. C0 i- \rev z5a 411E 'f # f- Id coa %It &„ . Tes4 hofps r(f� "I vie �Pr �l�"1 44 ver>�.1 � -9&PA sep����, �� � bt vbGV &r 7 per eole 1°erea�o.�, �,� ��s s rW.WVfd Sc�C'k ��o�� w\ � .0r�1, vis � dam; �` Id are Wt�11�� 3c; r� pev'coh tt' k-� Receivi Issued ti C 0 1 Municipality of Anchorage P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Division On -Site Water and Wastewater Program went S a � Department **** VARIANCE/WAIVER REVIEW **** Waiver#: OSP151003 COSA#:OSC151001 Permit#:OSP141530 PID#: 020-161-28 Legal Description: Marguerite Hills, Lot 1A-3 Engineer: Anderson Engineering Applicant: Redhawk Development AK Your request for a waiver of the required 50 feet horizontal separation from the absorption field to 25% or steeper slope has been approved. The approved separation distance is 10.0 feet. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of non -objection have been received from the owner(s) of the affected adjacent property. ® Adjacent properties are not affected by this waiver. ................................................•.............................1 Waiver is Granted: X Waiver is not Granted: Date: S Approved b . Fame of Reviewer .......................................................................... MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program RU► Parcel I.D. ON-SITE SEWERMlELL PERMIT APPLICATION i 020-161-28 Property owner(s) Dave Mattison M 'I'dd ess P.O. Box 110467, Anchorage, AK 99511 al mga f Site address 7670 Big Mountain Drive Anchorage, AK 99516 Legal description (Sub'd., Block & Lot) Marguerite Hills, Lot 1A-3 Legal description (Township, Range & Section) Number of Bedrooms Five (5) Day phone s Lot Size 391,349 Sq. Ft. APPLICATION IS FOR: IS all that apply) Absorption Field RX Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ APPLICATION IS AN: Initial ❑ Upgrade ❑ Renewal ❑X TYPE OF DWELLING: Single Family (SF) ❑X (w/wo ADU) Duplex (D) ❑ Multiple Dwellings ❑ (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: �� Distance:1_ I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: lyo -1- F- = 2,2-14— Waiver Fees: Date of Payment: l 2j 1-11 lu t Date of Payment: S Receipt Number: 0Ife" 3 G Receipt Number: 0451( `s Permit No. 0.5 Ply 145 � Waiver No. 6916 1 5106 Permit App_ 1 : C00� December 30, 2014 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 1A-3, Marguerite Hills Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: A permit was issued for the construction of a well and septic system for Lot 1A-3, Marguerite Hills Subdivision in January of 2000. The septic tank was placed and the existing well was constructed. The absorption trench was constructed but not at the design location or under the supervision of a registered engineer and no inspection report or as built documentation was ever completed. We are therefore requesting the permit be renewed for the construction of the septic system to accommodate the home. The original design required construction of the new system based on test holes which cannot be located. In addition, the design did not meet Municipal requirements for placement parallel to the contours of the ground surface. We have redesigned the absorption system based on new test holes and in conformance with Municipal Code. The attached Site Plan and backup documentation identify the location and configuration of the existing well and proposed/existing absorption trench along with the alternate site. The septic tank will be exposed and verified suitable for continued use. The existing absorption trench will be utilized as much as possible and verification test holes will be placed every 25' along the alignment of the trench to verify the 6' separation to bedrock. The lot is large and no conflicts exist between the existing well and septic system and wells or septic systems on adjacent lots. Ground surface contours are shown on the site plan showing the grade and direction of flow. The drainage pattern will not be changed as a result of this project. The test holes placed on the lot in the area of the absorption trench and alternate site indicate sandy gravel (GW). The percolation rate of the soil was determined to be between 1 and 5 minutes per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period or to date. Bedrock was encountered from 8' to 12' below the surface. No bedrock outcroppings were noted however and no bedrock is suspected to daylight within 50' downgrade of the proposed absorption trench. An application rate of 1.2 gallons per day per square foot was used in the design of the absorption system. We are proposing to utilize the existing 1,500 -gallon septic tank and construct a new 100' long by 5' wide by .5' effective depth absorption trench utilizing the existing trench as much as possible to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 1.5' below the surface and the total depth will be 2.0'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. 309 Lot 1A-3, Marguerite Hills Subdivision May 27, 2015 Page Two The ground surface on the lot in the area of the septic system slopes to the south at steep grades. The new trenches will be constructed parallel with the contours of the slope as much as possible in conformance with Municipal requirements. A slope waiver is included allowing placement of the trenches less than 50' from slopes greater than 25%. Fill will be required to flatten the slopes down grade from the new trenches. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments 49th MICHAEL E. ANDERSON / / r `\ I / \ I � I 1 \ I 1 1 \ I I \ p Q I / Existing Well \ I I \ I `\ NOTE: No Surface Water Within 100' of Proposed SepticSystem I { LEGEND Si — Septic Vent CO — Clean Out M1 — Monitor Tube TH — Test Hole '1 FCO — Foundation Cleanout 1 1 1 1 1 1 1 1 , 1 \ 1 1 1 1 1 ALTERNATE SITE: Advantex Treatment System w/30' Long by Wide by No Effective Depth Absorption Trench. Application Rate 4 11 �1 GPD/SF. 1 1 , 1 1 \ 1 1 1 , l , 1 , �I 1 i Verify Existing Absorption Trenrh Long x 5' Wide x I Effective Depth. Existing and Proposed Absorption Trench 100' Long x 5' Wide x No Effective Depth. 1A-3 MARGUERITE HILLS SITE PLAN SCALE V = 50' 1 _ --------- IQ' T & E Esrot r 49th MICHAEL E. ANDERSON No. CE -4361 0 LOT 1A-3, MARGUERITE HILLS SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home 5' Wide Trench System Perc. Rate: 1-5 Min./Inch Verify Integrity of Existing 1,250 Gallon Tank Application Rate: 1.2 GPD/SF .5' Drainfield Rock 4 Bedrooms * 150 GPD/Bedroom = 600 SF Absorption Area 600 SF/1.2 GPD/SF/5 SF (Width) = 100 LF Trench Length THEREFORE: Construct a 100' Long x 5' Wide x .5' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 1.5' Below Original Ground Surface. Total Depth to be 2' Below Existing Ground. Provide 2' Cover Over Absorption Trenches and 4' Cover Over Septic Tank. Verify Existing Septic Tank is Suitable for Continued Use. Existing fir fi to Mound Topsoil to Prevent Erosion 2" Insulation & Geotextile Fabric 61 1 Hoes DoPerforated PVC 6" , 5' " Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION .....aF.,��� (NO SCALE) ���PCE......... 1C 1C� NOTE: Grade Area Over Trench to Drain Away. p ; �yrp Minimum 6' Separation From Bedrock.;. 49th 6V Minimum 4' Separation From Groundwater. Minimum 100' Separation From Private Wells in the Area. ;A I. MICHAELE.ANDERMN Minimum 100' Separation From Surface Water or Streams:„q, MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: DATE: 11128/14 PROJECT No.: PARCEL ID#: TECHNICIAN: WR DEPTH TEST HOLE 1 (feet) OL/OG 1 K 3 5 GM/SM SILTY GRAVEL WITH SAND 6 7 8 Bedrock 9-� LO WAS GROUNDWATER IFYES WHAT D DT No IF YES (j WHAT DEPTFI7 I I DEPTH OF WATER AFTER MONITORING:None pp DATE OF MONHORIN&r l -15-14 E 1 1 1 DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To (INCHES) WATER NET DROP (INCHES) 11-28 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 11:03 2.375" 2 11:33 30 9.625" 7.25" 3 11:34 2.50" 4 12:04 30 9.75" 7.25" 5 12:05 2.50" 6 12:35 30 9.75" 7.25" PERCOLATION RATE: 4�/INCH) PERC. HOLE DIA.—b (INCHES) TESTRUNBETWEEN: 4 FT. and S FT: COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 12-28-14 on MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: DATE: _ PARCEL DEPTH (feet) 1- 2- 3- 4- 5- 6- 7- 8- 9- 11 12 13 14 15 16 17 OL/OG Lot IA -3 PROJECT No.: TECHNICIAN: WR TEST HOLE 2 GM/SM SILTY GRAVEL WITH SAND Bedrock WAS GROUND WATER ENCOUNTERED? No IF YES @ WHATDEMP DEPTH OF WATER AFTER MOMTORWo: None pE DATE OF mown ma- I2 -I5 -I4 COMMENTS: TEST HOLE PRE SOAKED PRIOR TO DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER (INCHES) NET DROP (INCHES) 11-28 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 1:14 1.25" 2 1:44 30 7.7511 6.50" 3 1:45 1.50" 4 2:15 30 8.00" 6.50" 5 2:16 1.25" 6 2:46 30 7.75" 6.50" PERCOLATION RATE: 4.6 (MIN wcm PERC. HOLE DIA.6__IINCHES) TEST RUN BETWEEN: -�L FT. and SFT. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 12-28-14 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: DATE: — PARCEL DEPTH (feet) 1- 2- 3- 4 - 5- 6- 7- 8- 9 - OL/OG Lot PROJECT No.: TECHNICIAN: AH TEST HOLE 3 GM/SM SILTY GRAVEL WITH SAND Bedrock 10-7WAS GROUND WATER ENCOUNTERED? No IF YES @ WHAT DEPTH? II DEPTH OF WATER AFTERMONITORAIG:None DATE OF MONITORING: 1245-I4 PF 17 14 15 16 17 18 19 it E AMWRMN CE -4381 . DATE READING GROSS TIMEJ (MINUTES) NET TIME (MINUTES) DEPTH To W4TER (INCHES) NET DROP (INCHES) 12-14 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 2:09 2.06" 2 2:39 30 8.75" 6.69" 3 2:40 2.00" 4 3:10 30 8.75" 6.75" 5 3:11 2.25" 6 3:41 30 9.00" 6.75" PERCOLATION RATE;4.4 fMIN/INCH) PERC. HOLE DIA._b ¢NCHES) TEST RUN BETWEEN: -A—FT. and -5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 12-28-14 col MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: DATE: I L/ I4/ 14 PROJECT No.: PARCEL ID#: TECHNICIAN: All DEPTH TEST HOLE 4 (feet) 6 A�rl?ffl MM ri 10 WAS GROUND WATER ENCOUNTERED? NO C IFYES@WHATDEMV t�ytC'(S LI DEPTH OF WATERAFFERMOMTORm: None DATE OF MONmgiNO: 12-15-14 77 I I DATE READING OL/OG 1111111 DEPTH To WATER (INCHES) NET DROP (INCHES) 2 TEST HOLE PRESOAKED PRIOR TO TESTING: 3 2:24 4 2 2:54 GM/SM 5 7.00" SILTY GRAVEL 3 2:55 WITH SAND 6 6 A�rl?ffl MM ri 10 WAS GROUND WATER ENCOUNTERED? NO C IFYES@WHATDEMV t�ytC'(S LI DEPTH OF WATERAFFERMOMTORm: None DATE OF MONmgiNO: 12-15-14 77 I I DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER (INCHES) NET DROP (INCHES) 12-14 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 2:24 0.75" 2 2:54 30 7.75" 7.00" 3 2:55 1.00" 4 3:25 30 8.00" 7.00" 5 3:55 0.88" 6 4:25 30 7.88" 7.00" PERCOLATION RATE:4.4f&nN/INCH) PERC. HOLE DIA.—6 ¢NCHES) TEST RUN BETWEEN: 4 FT. and __FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 12-28-14 a MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: DATE: '/ PARCEL ID#: DEPTH (feet) 1- 2 3 4 5 6 7 8 9 OL/OG Lot IA -3 PROJECT No.: TECHNICIAN: MEA TEST HOLE 5 GM/SM SILTY GRAVEL WITH SAND SLOPE 1 Q WAS GROUND WATER ENCOUNTERED? No S IF YES Q WHAT DEPTH? 11 DEPTH OF WATER AFTER MONITORING: None p0 DATE OF MONITORING: 12-15-14 C Bedrock 14 15 16 17 ° 49th AEL E. ANDERSON No. CE -4381 . S- f 7-1.4e C It a DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER (INCHES) NET DROP (INCHES) 1 2:24 2 2:54 3 2:55 4 3:25 5 3:55 6 4:25 PERCOLATION RATE (MIN/INCH) PERC. HOLE DIA. (INCHES) TEST RUN BETWEEN: FT. and FT. COMMENTS: TEST HOLE ONLY TO VERIFY BEDROCK DEPTH. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 5-27-15 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 DEPTH (feet) 1 - 2 3 4 5 6 7 8- 9 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: Marguerite HMS Lot 1A-3 PERFORMED FOR: Dave Mattison DATE: 5/19/15 PROJECT No.: PARCEL ID#: TECHNICIAN: MEA TEST HOLE 6 OL/OG GM/SM SILTY GRAVEL WITH SAND 10 WAS GROUND WATER ENCOUNTERED? No S IF YES Q WHAT DEPTH? LG 11 DEPTH OF WATER AFTERMOMTORING: None DATE OF MONITORING: I2 -I5 -I4 C Bedrock 15 16 17 18 4L 49th MICHAEL E. ANDERSON DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER (INCHES) NET DROP (INCHES) 1 2:24 2 2:54 3 2:55 4 3:25 5 3:55 6 4:25 PERCOLATION RATE (MINANCH) PERC. HOLE DIA. (INCHES) TEST RUN BETWEEN: FT. and_FT. COMMENTS: TEST HOLE ONLY TO VERIFY BEDROCK DEPTH. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE, GUIDELINES IN EFFECT ON THIS DATE: 5-27-15 col ANDERSON ENGINEERING P.G. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX December 30, 2014 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 1A-3, Marguerite Hills Subdivision Absorption Trench to Slope Waiver Alternate Site Dear Onsite Services Engineer: Lot 1A-3, Marguerite Hills Subdivision has limited area for construction of a septic system due to a steep slopes on the property. We have located an area with acceptable soils, but bedrock was found at 8' below the surface limiting the depth of the distribution lines. The primary and alternate sites will be approximately 10' from an existing slope greater than 25%. We are therefore applying for a waiver allowing placement of the primary and alternate sites at the location shown. Soils in the area are very good for the treatment and absorption of septic effluent. The majority of absorption will be down and migration will be minimal. The imaginary 25% slope from 2' above the distribution line will daylight at 23' from the edge of the alternate site and more than 50' from the primary site if fill is placed as shown on the attached drawing. We therefore recommend a waiver be issued allowing placement of the primary and alternate absorption trenches within 10' of a slope greater than 25%. Sincerely, JJ /� 'tom ,�Kt1 � {! e Michael E. Anderson, P.E. .• 49th ,ms's MICHAEL E. ANOER3 N No. CE -4381 c©1 1 00 ISA y`���s LO ,� ;Uy . a W vfn, i oW E a z 4 � tC) o.rkc0 NMI i O in � z L07 "Lo LU M O rr) LLQ Cf) Q ,.� r W �— =0CO Z 0ri WJQ �LLJLLJ z° LO n J N w0 Q D J O cn N Q to O O d ON O O toO N O 07 1� n c0 t0 In X1'1 n r r n r r r r r r r r r « 41 O a B� N V1 « m m m d &g �o 0 4�0 N m N O m«m fwo m- « 0wN 3� 's mc« NOTE: Application must be filled out completely Property Owner Name Uylj\� Mailing Address -Ii�a Legal Description Lot Lot Sizejftl „ears . Ft. MUNICIPALITY OF ANCHORAGE Department of Health & Human Services On -Site Sewer/Well Permit Application 02 d f SINGLE FAMILY DWELLING Parcel identification Number _3 Number of Bedrooms 81c Day Phone r1 S F'l� Zip CodeX51 Inspections will be conducted by: jo Approved Engineering Firm ❑ Municipality (permit fee included) Does your house contain any of the following.-ZEJ�Hot Tub ❑ Swimming Pool ❑ Therapy Poolacuzzi E] Water Softener Unit This application is for. ewer Only ❑ Sewer and Weil ❑ Sewer Upgrade ❑ Well Only ❑ Water Storage certify that the above Information is correct. I further certify that this application is being made for a Single Family Dwelling and in accordance with applicable Municipal Codes. P pe Owner/Well Driller Waiver FE 72-012 (Rev. 419e) - Receipt M Receipt Permit M Waiver W1 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On -Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ONSITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Permit Number: SW000008 Legal Description: MARGUERITE HILLS LT 1A-3 Date Issued: Jan 25, 2000 Expiration Date: Jan 24, 2001 Parcel ID: 020-161-28 Design Engineer: 0062 Pannone Engineering Services Site Address: Owner Name: Dave Mattison Lot Size: 391349 SQ. FT. Owner Address: PO Box 110467 Total Bedrooms: 5 Permit Bedrooms: 5 Anchorage . AK 99511-0467 This permit is for the construction of: 0 Disposal Field Q✓ Septic Tank ❑ Holding Tank ❑ Privy Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received Issued Date: 1 —25 —oo Steven 2 Pannone, RE P.O. Box 102954 Consulting Engineer Anchorage, Alaska, 99510 (907)227-3522 (907)272.8218 Fax January 10, 2000 Municipality of Anchorage Dept. of Health & Human Services On -Site Services Section P. O. Box 196650 Anchorage, Alaska 99519 Subject: Lot lA-3 Marguerite Subdivision Well and Septic Permit Gentlemen: My firm was contacted to investigate the possibility of installing of a new system at the above referenced property. Currently the lot is undeveloped. Three test holes were excavated on September 26, 1994. The soil report and percolation test results are on file with your department. A copy of the soils logs are attached. Ground eater was monitored for seven days. No ground water was encountered or monitored. Test hole two encountered bedrock at eleven feet below ground level. No bedrock was encountered in test holes one or three. The lot is approximately 40 acres in size. The owner plans on subdividing Lot 1 into three lots. Lot 1 slopes to the southwest at a rate of approximately 10 to 15 percent The proposed installation will be located on the southern portion of the lot, and on the western portion of Lot IA -3. The proposed location will be greater than 100 feet away from the proposed well serving this property and 25 feet from the water service lines. The surrounding systems are located greater than 200 feet from the proposed installation, the lots to the north, south and east are undeveloped. The proposed installation shall not impact the future development of the surrounding or existing lots. See attached design. The new system will maintain over six feet vertical separation to the bedrock and over four feet vertically to the ground water. If you have any questions about the proposed installation, please contact me at 272- 8218 _.•""���._ Sincerely, Steven rtnone, P.E. Attachments: P.............. 4t TH :. 4()— Steven Nn. FS 0 TP DESIGN WASTEWATER ABSORPTION SYSTEM LOT IA -3 MARGUERITE SUBD. TP 1 LOT IA -1 PROPOSED PRIMARY 6 RESERVE SOIL ABSORPTION FIELDS 5 BR. HOUSE 625 SF ROD 2' WIDE x 5' EFFECTIVE x 63 LF B' TOTAL DEPTH. LOT IA -2 THERE ARE NO WELLS WITHIN 200' OF PROPOSED SYSTEM. EXISTING SEPTIC SYSTEMS ARE LOCATED ATER THAN 100' AWAY. PROPOSED PRIMARY 6 RESERVE SOIL ABSORPTION FIELDS ? 5' WIDE x 2' EFFECTIVE x 70 LF z 3 5' TOTAL DEPTH. y W TP 2 THERE ARE NO WELLS OR SEPTIC w �H SYSTEMS WITHIN 200' OF PROPOSED W W SYSTEM. S Detail Area. g 'See Sheet 2 of 3. 1/3 IA -3 NOTE, BY CONSTRUCTING THE SYSTEMS ON LOTS 1B 6 1C. FUTURE DEVELOPMENT ON �\ SURROUNDING LOTS WILL NOT BE AFFECTED. Proposed salt absorption system. See Sheet 2 of 3 SITE PLAN L 49Di en R. Pannone:IMr. Dave Mattlson No. CE 149 �P.O. Box 110467 Anchorage, AK 99511 (907) 345-8715 PANNONE ENG. SVC P. ❑. BOX 142025 ANCHORAGE, ALASKA 99514 227-3522, 272-8218 Fax 1TE, 1 -Io -'o DESIGN =ei c. �•=ann• w zw J3.y JN W fa Z y 0 ¢ud ixy O 0 f DESIGN WASTEWATER ABSORPTION SYSTEM LOT IA -3 MARGUERITE S/D Y u Proposed Vell 'f A N o', Proposed is b� 5 bedroon house I ew 1500 g 15X Septic Tank •Diverter valve loc'n Primary Absorption Field 63LFx5'EFFx3'W Secondary Absorption Field. It may be Installed at sane time as primary. A dlverter valve rill be Installed between the two systems If secondary system Is Installed. UNDEVELOPED 2/3 N Q I W �> W 0z JD Solt Rating = 125 sf/br 5 Bedroom House 625 sf Rqd Design, 5' Effective 8' Total Depth 2' Wide, 63' Long Total Effective Absorption = 630 sf VRILVAKtU F UK, PANNONE ENG. SVC Mr. Dave Mattison P. O. BOX 142025 P.O. Box 110467 ANCHORAGE, ALASKA 99514 Anchorage, AK 99511 227-3522, 272-8218 Fax (907) 345-8715 DATE, 1-10-00 1DESIGN rrw: r. „_mnr DESIGN DETAILS WASTEWATER ABSORPTION SYSTEM LOT 1A-3, MARGUERITE S/D d CL u FL d Y C4 O K N d C 1. z' A r o 111 � 1 1 / Y i / 49TM No. CE 8149 rQi Mr. Dave Mattison LroalD ay�� P.O. Box 110467 Anchorage, AK 99511 (907) 345-8715 inm 0 c 0 J [7 �D u C d H CL d A inCNV3U a c inCWV3M_ u C C lei tl 00 lf1@11/317iij apl NMIVaNnOJ 3/3 W J LL H ^E^,, ry n u C d C C � IW U9 Z....Y PANNONE ENG. SVC. P. 0. BOX 142025 ANCHORAGE, ALASKA 99514 227-352 272-8218 FAX NTE. t-Io-oo DESIGN ❑T n TALE ___ • � Los .. � munklpality of Anehora9a 4a DEPARTMENT OF HEALTH d HUMAN SERVICES /• +4•.•.+a.. o+r.�•�».•• •' 625 "L" Street, Anchorage, Alaska 99502.06'0 s� SOILS LOG — PERCOLATION TEST ����� lem7+:. •p •, 81317E ,•"p�f PERFORMED FOR: 0a- ) /' pt a.- -i''d P7 , DATE PERFORMED!Z ( LEGAL DESCRIPTION: "�i'Z'v'9�Uer�� VWnship,Range.Section:t%IN � Jw _. _. SrnpP SITE PLAN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 - 15 r749 /1 ; C- r7.) Si ! t -i', !�a'(adr (g-rc?vrl atv� Nol e IF YES, AT WHAT DEPTH? Cepth It Wner A8 r G Monitoring? �•! ■■■■■■M■-' ■■■■mdi% ■ ®®m®® �.ZMWW li redo. Kmi � �. � ■.r•�r.�..� tea. �� ��rr� �rsycac�■� ��■�r���a���lrr� 20L ' I PEPCOLATICN RATE L1 ' Immu:sa.mcht PERC HOLE DIAMETER � TESTRUNEETWEEN ^' FT AND —j�—FT COMMENTS 5a4 -i -S FIE -7 /Y ,Gc.-C- PERFORMED BY: • dr G. ERTIFY T AT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL OUIDEL ES IN EFFECT ON THIS DATE. DATE. 7 <Gi 72 -WB (Ft". 4183) �" e of ;...<•...,•� i p•�. Municipality D1 Anchorage d A fCOTF{?�?� S i "���//�•// DEPARTMENT OF HEALTH 6 HUMAN SERVICES �+• "" '•'" * ° •• ^•«t•' 825'L' Street. Anchorage. Alaska 99502-0650 .... / SOILS LOG — PERCOLATION TEST Epi w.'�•:. , <•°' �%J.+ PERFORMED FOR: -��(— b"L• !YT 7—� ✓U/�� �,�. DATE PERFORMED:�";''r LEGAL DESCRIPTIO �� ln'cIG �l OA ownship, Range. Section:?; 1bV /T 3 GV SCG /2- 1 Z 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 5 agdx G-g2w,10, OGG25jlvna16:50e :7-rSGG� 5f if�7 =®®®m WASGROUND WATER • FO ENCOUNTERED? N 2 F0c4Wred i's. L IF YES. AT WHAT C DEPTH? P Noy e E / i.•,u• Bepm to Water-� Mandcring7 8•Is =®®®m m�i�. 20 { IL._—!I PERCOLATION RATE —e `= tmmufe>V lnl!cnl FERC MOLE DIAMETER Ic- TEST PUN BETWEEN -!2 FTANDFT COMMENTS �, 2 PERFORMED BY. " • _7r�fL� I CERTIFY THAT THIS TE T WAS PERFCRMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELI S IN EFFECT ON THIS DATE. DATE.? 72-008 {Rw. 41051 C lIL%• Municipality of Anchorage DEPARTMENT OF HEALTH Q HUMAN SERVICES 825 •L" Street. Anchorage. Alaska 99502.0650 SOILS LOG — PERCOLATION TEST low 44 7 Z'. M I l .' • y Fr„�a o i ri' w !0 � m •h PERFORMED FOR: ? G�� - DATE PERFORME 7nw ns hin Fiance. Section: LEGAL 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 19 20 COMMENTS Lq n? t� S a 2d v., qr vei rr�a G P t3 C' -F- I/C'(e WAS GROUND WATER \ ,p ENCOUNTERED? l.� / L IF YES, AT WHAT L-� D DEPTH? `' E Rr Depth to W&AiUr/b 3 monilorind? Dek PERCOLATION RATE Immulavincn) FERC HOLE DIAMETER FT AND�FT PERFORMED By. % I ' (31 ' .(�u�{ .6•- CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL r."nnm i s ON HIS DATE DATE. 72-008 tRev 4.851 1NEFFECT ® A, a Municipality of Anchorage Department of Health and Human Services 825 V Street P.O. Box 196650 Anchorage, Alaska 99519-6650 Rick Mys4rom http:j wrw.c1.enchorage.ak.us Mayor Permit Number: #SW 000008 Date of Issue: 1-25-00 Parcel Identification Number: 020-161-28 Date Started: 10-3-00 Date Completed: 10-4-00 Is well located at approved permit location? ® Yes ❑ No Legal Description: Mamurite Hills Lt 1A-3 property Owner Name & Address: Dave Mattison PO Box 110467 e....t........r. AL OOFII hole Data: Depth (ft) ype, Thickness & Water Strata From To Method of Drilling ® air rotary ❑ cable tool Casin e• steel gbP -up 0 2 elly silt 2 9 r rock g 5P7 Wall Thickness:.025 inches Diameter: 6 inches Depth: 20 feet Liner Type: Diameter: inches Depth: feet Casing stickup above ground: 2 feet Static water level (from ground level): 151 feet RECEIVED Pumping level: 527 feet after 24 hours pumping:2 gpm OCT 30 2000 Recovery Rate: 3 gpm Method of Testing: airliff Municipality of Anchorage Dept Health &Human Services Well Intake Opening Type: ❑ Open End ® Open Hole ❑ Screened Startfeet Stopped - feet [:]Perforations Startfeet Stopped feet Grout Type: Benionire # 8 Volume: 1 br Depth: Start 0 feet Stopped ± feet Pump: Intake Depth feet Pump size hp Brand Name Well Disinfected Upon Completion? ® Yes ❑ No Method of Disinfection: Clorine Tablets Comments: Well Driller: Alpine Drilling & Enterprises P O Box 110496 Anchorage AK 99511 Attention: The well driller shall provide a well log to the property owner within 30 days of completion and the property n�vnnr nr /hn tvnll ilrillor shell nrnviAn a tvnll Inn In thn 11 nt ^ Ll.otth .0 1411m0n An clava of rnmntnt:nn Parcel I.D. 020-161-28 Municipality of Anchor ®2 X015 9a On -Site Water and Wastewater Progra 0� n (907) 343-7904 g6 �,�}?� SAI r r Certificate of On -Site Systems Approva Expiration Date: /to - -ri. - /-5� 1. GENERAL INFORMATION Complete legal description Marguerite Hills, Lot 1A-3 Location (site address) 7670 Big Mountain Drive Anchorage, AK 99516 Current Property owner(s) Redhawk Development AK Day phone Mailing address P.O. Box 10859 Zephyr Cove, NV 89448 Real Estate Agent Day phone 2. TYPE OF DWELLING: R Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: Four 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well E Individual 0 Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received Icy; - Date: & _5� COSA to be released theengine unless oth Ienvise requested by the engineer. COSA Fee $ail Date of Payment Receipt Number — COSA# ©SC. --%66"/06 ( Waiver Fee $ Date of Payment Receipt Number, Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the ot5-sife'water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. 6. DSD SIGNATURE System #1 Approved for bedrooms System #2 Approved for bedrooms Disapproved Conditional approval for bedrooms, Date 7/2/15 A MICH46TA BERSON t9� J'.• CE -4381 0 �x•.. '� Ern. f6'L with the following stipulations: By:�U. Original Certificate Date: The ni i I t Ano a Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered In the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet r :.. c If more than 1 septic system is on the lot: COSA Checklist # _of _ Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: Marguerite Hills, Lot 1A-3 A. WELL DATA Well type Private If A, B, or C provide PWSID # Date completed 10/4/00 Sanitary seal (Y/N) Y Total depth 527 ft. Cased to 20 ft. Date of test Static water level FROM WELL LOG 10/4/00 151 ft. Well production 3 g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 mL Nitrate '94'4 mg1L Arsenic ND ug/L Date of sample: 11/18/14 Parcel ID: 020-161-28 Well Log (Y/N) Y Wires properly protected (Y/N) Y Casing height (above ground) >18 in. AT INSPECTION 11/28/14 143 ft 1.8 g.p.m. Collected by: Anderson Engrg. B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 6/2000 Tank size 1,500 gal. Number of Compartments 2 Cleanouts (Y/N) Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) Date of pumping 1/12/15 Pumper Chugach Sewer and Drain C. ABSORPTION FIELD DATA Y N Date installed 6/1/2015 Soil rating (g.p.d./ftZ or felbdrm) 1.2 GPD/SF System type 5' Wide Length 100 ft. Width 5 ft. Gravel below pipe `5 ft. Total depth 4.2-5 ft. Eff. absorption area 5O0 fe Monitoring tube Y Depression over field N Date of adequacy test New Const. Results (Pass/Fail) For _ bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. N Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date D. LIFT STATION Date installed Size in gallons _ "Pump on" level at in. 'Pump off" level at Datum Cycles tested E. SEPARATION DISTANCES WELL ON LOT TO: Septic tanMift station on Absorption field on lot Public sewer main Sewer /septic service line >100, >100, >100' >25' Animal containment areas >50' SEPTIC/HOLDING TANK ON LOT TO _ Manhole/Access (Y/N) _ in. High water alarm level at Meets alarm & circuit requirements? On adjacent lots >100' On adjacent lots >100' Public sewer manhole/cleanout >100, Holding tank >75' Manure/animal excrete storage areas >100' Building foundation >51 Property line >5 1 Absorption fie , Water main >1 0Water service line >1 0Surface water Wells on adjacent lots >100, ABSORPTION FIELD ON LOT TO: Property line >10' Building foundation >10, Water Service tine >10 Surface water >100 Curtain drain None Noted Wells on adjacent lots >100, F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 7/2/15 COSA brown sheet 10-10-12.doc d >51 >100, Water main N/A Driveway, parking/vehicle storage >I 01 w00 *; jo'• • go 1. i... ... MICHAEL E. ANDERSON : 4 CE -4381 .'gni Ilk .- FfSS10N���� in. A A• 5 g9L' o w l �jh gfO 1 Mountainside 1 N 00002'00" W 909.23' 1� �U Village I P / CO 67, A�—,bZbZ E N W H LO / Subd. / M L U ) U C L C 0 E 3 v EO 75 m v 00z /9R J o U C L C 0 E 3 v E w s o Ln U v `o Ln 46 C d0 c 'n v @ O O O C v z N v> Y m u z Q �` Z L a 'C w L C i w el J p� O >: rc C w W v m 6 w m a a L N i LL a o w Eti s N O V • w c o Q Q� _ = �Ds=oo0N W ° N — N o= L O N O N K v C 3 O .'^Uw Uw L �^ =tai 3 L W L Q V^O V1 w U U O Q .0 z L m } l9 U m o Ui i wQ 0 O J u a v n / / z \ / J \ / / U 1 / Q 1 / m / N / W / m O O / V / O / 0_ / O / O m /Y U = O � O. •,s\. i9�8 � °. 0 5' Bo\Cony . — — 6 N Ito AIWrte. �s 1� E ' �6 Wall � �. M • a LA • Z Retaining LL.: . o _ m IIoM 6wulo;aa / O'. F s o : o Lower Concrete Walkway t .��. d Gni AW Upper Metal Walkway ,� •(S : R� •r m VJFAFJ` «. Municipality of Anchorage On -Site Water and Wastewater Program (937)343-7904 Municipality of A,TUNi oiag Certificate of Ori -Site Systema Approval Building S0ety Division Expiration Date: —r— Marguerite1. GENERAL INFORMATION Complete legal description t. Location (site address) 7670 Big Mountain Drive Anchorage, AK 99516 Current Developmenti' _ Day phone Property3 y Mailing address P.O. Box 10859 Zephyr Cove, NV 89448 Real Estate Agent d'1 ✓ s S w- Day phone i o 0 7 D 2. TYPE OF DWELLING: ❑ Single Family (w/woADU) ® Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 4. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class well Public Water System Waiver/Variance request TYPE OF WASTEWATER DISPOSAL: [] Individual [] ❑ Holding Tank ❑ ❑ Community ❑ RAS Received by: COSA to be released to the engineer, unless othervAse requested by theengineer. in, '7I . -tNQ CASA Fee ©ate of Pa) Receipt Nu COSA# I (n Date: 1 - Waiver Fee $ Date of Payment Receipt Number. Waiver # 051� 6. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of fan -:site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that bared on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O. Box 240773 Anchorage, AIC 99524 Engineer's Printed Name Michael E. Anderson, P.E. 6. DSO SIGNATURE System #1 Approved for System #2 Approved for Disapproved t� Conditional approval for bedrooms M Phone 522-7773 Date 1/2/15 bedrooms, with the following By: C Original Certificate Date: The Munict all n rchorage Devaiopment Services Division (DSD) issues Certificates of On -Site Systems Approval (CASA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS. COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other GOSH blas sheet f - , c If more than 1 septic system is on the lot: COSA Checklist # Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: Marguerite Hills, Lot 1A-3 Parcel ID: 020-161-28 A. WELL DATA Well type Private If A, B, or C provide PWSID # Well Log (Y/N) Y Date completed 10/4/00 Sanitary seal (Y/N) Y Wires properly protected (YM) Y Total depth 527 ft. Cased to 20 ft. Casing height (above ground) > 18 in. Date of test Static water level FROM WELL LOG 10/4/00 151 ft. Well production 3 g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 mL Nitrate •944 mg/L Arsenic ND ug/L Date of sample: 11/18/14 B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Tank size 1500 gal. Number of Compartments 2 Foundation cleanout (Y/N) Y Depression over tank (Y/N) N Date of pumping C. ABSORPTION FIELD DATA Date installed 6/2000* Length Unknown ft Pumper AT INSPECTION 11/28/14 143 ft 1.8 g:p.m. Collected by: Anderson Engrg. Date installed _ Cleanouts (Y/N) 6/2000** Y High water alarm (Y/N) N Soil rating (g.p.d.M2 or i'fibdrm) 1.2 GPD/SF System type Deep Trench width Unknown ft. Gravel below pipe Unknown ft Total depth 8-10 ft. Eff. absorption area UN fe Monitoring tube Y Depression over field N Date of adequacy test Results (Pass/Fail) For _ bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date D. LIFT STATION Date installed _ "Pump on" level at Datum Size in gallons _ in. "Pump off level at Cycles tested E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot > 100' Absorption field on lot >100' Public sewer main N/A Sewer /septic service line >25' Animal containment areas >50' Manhole/Access (Y/N) _ in. High water alar level at Meets alarm & circuit requirements? On adjacent lots >100' On adjacent lots >1 00' Public sewer manhole/cleanout Holding tank N/A N/A Manuretanimal excrete storage areas >100' SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5� Property line >5' Water main >10' Water service line >10' Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: Property line >10' Building foundation >10' Water Service line >10' Surracewater >100' Curtain drain None Noted Wells on adjacent lots > 100' Absorption field >51 Surface water >100' Water main N/A Driveway, parking/vehide storage > 10' F. COMMENTS Septic System to be Reconstructed in Spring of 2015. *Septic Tank and Drainfield Constructed without Inspection or Certification. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 1/2/15 COSA brown sheet 10-10-12.doc in. United Title Guaranty Cathy Palmateer, Escrow Officer 3350 Midtown Place Anchorage Alaska 99503 907-261.7566 phone 866.458.1678 fax January 13, 2015 Jeff Poet On Site Municipality of Anchorage Regarding: 7670 Big Mountain Drive Anchorage, AK 99516 Dear Jeff, Thank you for your phone call this afternoon. United Title Guaranty will be holding the escrow holdback for the completion of the new leach field as required by the Municpality of Anchorage. We will hold the funds until you or the authorized person in the On Site department of the Municipality of Anchorage approves the work and instructs us to release the funds. The legal description of the property involved in this transaction is: Lot One "A" Three (13A), MARGUERITE HILLS SUBDIVISION, according to the official plat thereof, filed under Plat No. 97-140, in the records of the Anchorage Recording District, Third Judicial District, State of Alaska. You have asked for the bids for the escrow holdback and they are attached for your review. I believe that Chris Swires have provided the proof of funds deposited into our escrow account. I have attached a copy just to be on the safe side. All of my contact information is below should you have questions or concerns and to contact me with your approval of the completed work. Thankyou DWD Cathy Palmateer Senior Escrow Officer United Title Guaranty Phone: 907-261-7566 Fax: 866-458-1768 Email: cathypC2utgalaska.com For additional assistance please contact Cheryl Waite at 907-261-7513 or email cherylw(cDutcalaska.com, or fax 866-355-2346 Receipt Record Date: 1/13/2015 Prepared By: Cathy Palmateer Remitter. Redhawk Development AK Land, LLC Amount: $38,700.00 Branch: 1314 -United Title Guaranty Agency, LLC Escrow Unit: 100 - United Title Guaranty - Dynamld Bank Account: WFAKU- Wells Fargo Bank(WFAKU) Incoming Funds Bank Name: Wells Fargo Type of Funds: Incoming Funds Check Number: Other File Number: 01314-21333 Receipt Number: 411 Remarks: (4041) Seller Deposit for Escrow Holdback for Septic - $38,700.00 Page 1 of 2 Chris Swires From: "MIKE ANDERSON" <andengr@gci.net> Date: Monday, January 12, 2015 9:09 AM To: "Chris Swires" <cswlres@remax.net> Attach: Change Order Resubmittal.pdf; Upgrade Estimates.pdf Subject: RE: Lot 1A3, Marguerite Hills - Conditional COSA Chris: I think the Clty has come around and will issue the Conditional COSA. I just had a positive conversation with them. Attached are the three estimates I received. We have to escrow 1.5 tlmes the highest amount. This is an expensive upgrade due to the location of the work, steep slopes and the presence of bedrock. The approved permitted design is also attached. Jeff Poet has stated that If you present proof of escrow he will give you the COSH. I will verify that with him later today and let you know. Please let me know if you have any questions. My bill will be forwarded to you shortly. Mike Michael E- Anderson, P.E.. Anderson Engineering ..... Original Message ----- From: "Chris Swires" <cswires®remax.neb To: "MIKE ANDERSON" <andengr@gci.net> Cc: Sent: Sun, i 1 Jan 201517:13:03 -0900 Subject RE: Lot 1A3, Marguerite Hills - Conditional COSA Mike, I really appreciate all you are doing! I hope we get an answer tomorrow on thisl Do you have the 3 bids or can Dave Mattison give you one to speed up the process? 1/12/2015 December 17, 2014 Stuart Gilbert, Contractor 17127 Eagle River Road Eagle River, Alaska 99577 Mike, My estimate for the reconstruction of the septic system proposed for Lot 1A-3 Marguerite Hills is $25,800.00. This estimate includes connecting to the existing line from the tank to the proposed lift station at an appropriate location and to otherwise build as designed. StuartGilbert Pomraning Excavation LLC 11120 Great Dane Circle Anchorage, AK 99516 (907)440.2831 reid@pomraning.org Address Marguerite Hills Lot 1A•3 P.O. Box 240773 Anchorage, AK 99524 Pomraning Excavation, LLC 'Estimate Date Estimate No. 01/02/2015 962 Exp. Date P.O. Number AAAMIwHt. We. , n# 1 ♦.f Service Activity. Quantity Rate Amount Excavate . Remove existing drain rock and pipe. 1 25,750.00 25,750.00 Reuse existing septic tank, install 500 gallon tank / lift station and two TX 6fY absorption trenches per Anderson Engineering's design. Haul in 10 loads of fill to cover drain field and to lessen the grade down hill from the trench's. Option • Option for job. 0 1,700,00 0.00 topsoil and seed the drain field area. Total $25,750.00 Accepted By Accepted Date PROPOSAL 12/17/2014 G & R Excavating P.O. Box 771212 Eagle River, AK 99577 TO: Anderson Engineering P.O. Box 240773 Anchorage, AK 99524 SUBJECT: Marguerite Hills, Lot 1A-3 Septic System Reconstruction DESCRIPTION: Reconstruct Septic System with new 500 Gallon Add On Lift Station, 2-60' Long x 5' Wide Absorption Trenches and fill to flatten finished slope. TOTAL: $25,000.00 All work to be completed to MOA Specifications.