Loading...
HomeMy WebLinkAboutCARR LT 3ACarr Lot 3A #015-163-78 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP241111 Work Type: Septic Renewal Tax Code Number: 01516378000 Site Legal Address: CARR LT 3A G:2640 Site Mailing Address: 11561 HILLSIDE DR, Anchorage Owner: LYONS BENJAMIN & EVA Design Engineer: NORTH RIM ENGINEERING This permit is for the construction of: Effective Date: Expiration Date Lot Size in Sq Ft: Total Bedrooms: 6/6/2024 6/6/2025 53005 2 Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: • Due to the high possibility that there is a field in the area of the proposed field, prior to construction, check for any existing field. Received By: S V AA iq-1 7' T— V-) Date: Issued By: n � Date: 2-0 Z MUNICIPALITY OF ANCHORAGE Development Services Department % Phone: 907-343-7904 On -Site Water & Wastewater Section _ Fax: 907-343-7997 ON -SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 01516378000 Property owner(s) LYONS BENJAMIN Mailing address 11561 HILLSIDE DR Site address Same Day phone 240-2474 Legal description (Sub'd., Block & Lot) CARRLT 3A Legal description (Township, Range & Section) Lot Size 53,005 Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field 0 Initial ❑ Single Family (SF) [l Septic Tank El Upgrade ❑ (w/wo ADU) Holding Tank ❑ Renewal Duplex (D) ❑ Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. 1Z, (Signature of property owner or authorized agent) Permit/Rush Fees: 1 / y Waiver Fees: Date of Payment: f- Date of Payment: Receipt Number: Permit No. 0.5P29 111 Receipt Number: Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc SteveEng.com Steve Eng, PE, PH 907-694-7028 SteveEngPE@gmail.com Date: 5/30/24 Number of Pages: 1 To: MOA On-Site Services Subject: Carr Lot 3A Advantex Septic System Permit Renewal Permit Renewal is requested. The project owner delayed the start due to market conditions. No work has been completed. The lot is in the same condition as the original design. Neighbor lots are developed with no changes. The existing 5-bedroom home advanced system upgrade is planned. Due to the site conditions, a Category III Advantex is required. Site conditions are the same. The design calls for a new shallow trench and Advantex. The entire subdivision is on wells and septic systems. This lot has been served by a private water well and will continue using the water well. The terrain slopes to the north. Thanks-Steve Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241111, Curtis Townsend, 06/06/24 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP221408 Work Type: Septic Upgrade Tax Code Number: 01516378000 Site Legal Address: CARR LT 3A G:2640 Site Mailing Address: 11561 HILLSIDE DR, Anchorage Owner: LYONS BENJAMIN & EVA Design Engineer: NORTH RIM ENGINEERING This permit is for the construction of: Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: cnt v Departine nt 11/4/2022 11/4/2023 53005 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage 5 All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: • Due to the high possibility that there is a field in the area of the proposed field, prior to construction, check for any existing field. n wed -&y: �[ SSc,te(A fU �nGii'oeer i o Date: Issued By: Date: MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTICM/ELL PERMIT APPLICATION Parcel I.D. 01516378000 Property owner(s) LYONS BENJAMIN Day phone 240-2474 Mailina address 11561 HILLSIDE DR Site address Same Legal description (Sub'd., Block & Lot) CARRLT 3A Legal description (Township, Range & Section) Lot Size 53,005 Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field 0 Initial ❑ Single Family (SF) 0 (w/wo ADU) Septic Tank 0 Upgrade FX 1 Duplex (D) ❑ Holding Tank ElRenewal ElMultiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: �7 Q6— Waiver Fees: Date of Payment: t'O ��� �i Date of Payment: Receipt Number:(a_) Receipt Number: Permit No. 0619 oc91009 Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client ForrnsTermit Application.doc SteveEng.com Carr Lot 3A SPECIFICATIONS & DESIGN GUIDELINES Wastewater System Sizing: This is an existing 5-bedroom, single family home. The septic system is failing. The owner wants to upgrade the system to a Category III Advantex. A design is submitted for a new trench & new Advantex w/Lift Station. The neighboring lots are developed as indicated in the drawing; this upgrade will not impact neighbor lots. Groundwater was recently monitored @ 6 depth. A 4 deep trench will be excavated. The easements are located on the drawing and are not encroached upon. A Category III application rate of 3 GPD/FT². Trench Length = 250 FT²/2 x 2 = 63 . No bedrock was encountered. Old holding tank will be decommissioned per UPC. Advanced system allows 2 separation to groundwater. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations. Connect New Trench To Advantex/Lift Station, steel, anti-floatation. Watertight couplings, inlet & outlet. 2500 gallons w/ 2 AX-20 pods. 5 minimum between the tank and trench. 10 to property lines. 3 of cover is required for trench or add insulation board. Solid pipe must be set on well compacted, stable soil 4 of cover or insulation is required for tank; an equivalent of 1 insulation for 1 foot soil cover. Tank & solid pipe must be set on well compacted, stable soil. 4 diameter cleanouts with airtight caps are required 1 to 4 from foundation wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10 from the tank positioned to provide cleanout access towards the tank and towards the absorption field. All cleanouts must extend to at least ground level. In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron. Trench to be placed level, minimum of 2 to groundwater, 6 to bedrock. Drain rock to be ½ inch to 2 inch screened. Drain rock to be distributed uniformly. Force main to be 1.25 Schedule 40 PVC or equal. Distribution pipe to be 1.25 Schedule 40 PVC w/ 1/8 orifice @ 24 on-center. Silt barrier (filter fabric) to be installed above the drain rock Smeared trench sides must be raked or scarified before drain rock placement Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, PVC Schedule 40. Sewer Service Line is minimum 2% slope Septic Tank to be pumped every two years or when required Insulation board shall be extruded direct burial polystyrene (Dow Styrofm HI/equal) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221408, Deb Wockenfuss, 11/04/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221408, Deb Wockenfuss, 11/04/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221408, Deb Wockenfuss, 11/04/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221408, Deb Wockenfuss, 11/04/22 ANCHORAGE 1 THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this. -29r' Day of &+669v' of 20_2- Z , by and between C' ire L.h, V V's , herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as Advantex located at (legal description) Carr Lot 3A 2. Maintenance, Repairs and Alterations. (Owner is required to read, understand and initial each section) Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. It s be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). L, Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page 1 of 3 $ L Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. L Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. (_ Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. 9 L, Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. �a L^ Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. `99L... Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Terms. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonvvaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of heOwner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severahility. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 OWNER: By: _� (signature) Date: Iv �&2. Z Sev\ (print name) STATE OF ALASKA ) ) ss. THIRD JUDICIAL DISTRICT } The foregoing instrument was acknowledged before me thisaT—day of 0Abail" NO A Y PUBMIn FOR ALASKA My Commission expires: 9 3{ ,2Dd-3 MUNICIPALITY: By: G{/� (signature) (print name) NOTARY PUBLIC REGINALD ALSTON STATE OF ALASKA Date: Z zZ Title: (rev. 05/18/2018) Page 3 of 3 ' Municipality of Anchorage Page of DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL'SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: Sl)t•/ Q g 0 y �D PID Number: 0y5 — f4'3 —7& Name System: ❑ New Upgrade &-.&I.,Wastewater Addre63: 7E 0 ABSORPTION FIELD C-o 1 0 Phone: No. of Bedrooms: O Deep Trench ❑ Shallow Trench O Bed O Mound ❑ Other LEGAL DESCRIPTION Soil Rating. Total Depth from original grade PD/ Ft. Lot: Bleck: Subdivision: Oapth to pipe bottom from original grade: Gravel depth beneath pipe 3 C FI Ft Township: Range: Section: Fill added above original grade: Gravel length: F . Ft WELL' ❑New ❑Upgrade Gravel width: Number of lines: DManca Dentin liner Ft. Ft Classification (Private. A,B.C): Total Depth: Cased To: Total absorption area: Pipe material: Ft. FL FI. Driller; Date Drilled: Sore weer level: installer. Dale installed, — 20 0A \ Ft. D IEFA N82—F� Yield:�i Pump sel at: Casmg holghl Above Ground: TANK Y GPM Ft. FI. SEPARATION DISTANCES ❑Septid olding OS.T.E.P. To Septic Absorption Lin Holing ubucrPristo Manufacturer. TAN� Capacity In Ions: From From Tank Feld Station Tank SawrLlMs 1 . y Wall- 130 3p Material: STI t� r Number of Con, Iartments: Surface t t o LIFT STATION Water Lot Size In gallons: Manufacturer. Line 3f7 "Pump on" level at: 'Pump " level at: High water alarm at: Foundation O CurtainPump NIt7 Make &Model Elac - al Inspections performed by: Drain BENCH MARK Remarks: I Q OIC S a t/ CL [1YW�C Location and Description: Qr Elsr /�,, �� Assumed Elevation: / a -ENGrNEER'S SEAL c Inspections performed by. Dates: 1st 2nd a Department of Health and Human Services approval+J' ''•:,,, • `' .,, -7- Reviewed and approved by: Date: /2 O , 72-013 IA" 9191) MOA 25 �I G I LOT 2 I � I � I` ) �I LOT 34 � ~ I I I I I ILOT !A I I �CJAC TANK FILLED WITH CONCRETE 00 GAL HOLDING TANK ....' V\ I I � I I LOT 10 '\ \ I LOT 5 i :e 49th VEN SPURKLAND No. CE -222 I I III < LOT I I � ,♦ J 0 50 0 50 100 150 200 250 .700 ?. SCALE., 1' = 100 FT. IUUHLIV WKUKKLANU 1'.L. LOT 3 CARR SID SEPTIC SYSTEM AS BUUILT 103 W 157H. AVENUE DOUGLAS NESS DATE. SEPT.. 1, 2000 (NCH. AK. 99501 (907) 779-3916 11 11561 HILLSIDE DRIVE SHEET. 1/3 GRID. 2640 PERMIT a S V990420 PID N 015-163-78 CAR0003I.DV6 RAIN CAP TYPII 6' PUMP ACCES r / r. 1' X 10' CONDUIT 1' GAL VANIZED L B. 4—FT BURY BACKFILL WITH DIRECT BURIAL VIRE SAND AND GRAVEL TO ALARM PANEL 90.4 90.2 1' PVC CONDUIT LiJ HIGH VAT£R ALARM ■ MERCURY SVITCH FL '4T 18' — 75.5' II 17' S TANDARD 4000 GAL, HOL DING TANK OF ANCHORAGE TANK .••PSE .........., b �0 NO SCALE 49th SPURKLAND CE -2225 BCNCH MARK. GARAGE SLAB ASSUMED ELEV. 100.00 Fl. 11LJBBLN SPUf2KLANU P.E. I I LOT 3 CARR SID I I SEPTIC SYSTEM DESIGN I 6751 W. DIMOND BLVD. DOUGLAS NESS DATE ANCH. AK. 99502-3904 SEPT. 1, 2000 .m" �eo_gnot 11561 HILLSIDE DRIVE SHEET. 3/3 GRID: 27J6 SY19900420 PID 015-163-78 CAR00033.DVIG MUNICIPALITY OF ANCHORAGE Department or Health and Human Services On -Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Permit Number: SW990420 Legal Description: CARR LT 3A Date Issued: Nov 24, 1999 Expiration Date: Nov 23, 2000 Parcel ID: 015-163-78 Design Engineer. 0007 Tobben Spurkland, PE Site Address: 011561 HILLSIDE DR Owner Name: Douglas Ness Lot Size: 53005 SQ. FT. Owner Address: 1400 W Benson Blvd, #150 Total Bedrooms: 5 Permit Bedrooms: 5 Anchorage . AK 00000 - This permit is for the construction of: ❑ Disposal Field ❑ Septic Tank Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: Z -.s Date: � 2 T.SPURKLAND P.E. 203 W 15th. Avenue, Suite 203 ANCHORAGE, ALASKA 99501 (907)279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN LOT 3 CARR SID DOUGLAS NESS Municipality of Anchorage Department of Health and Social Services 825 L Street Anchorage, Alaska 99501 October 29, 1999 We are submitting an application for the upgrade of the septic system for this lot. The submittal consists of three (3) drawings showing the present improvements on the lot and the adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only the septic system is subject to this permit application, (sheet 2/3), and a schematic of the septic system, (sheet 3/3). Soil logs and percolation tests of applicable testholes are also enclosed. The septic system design is based on the following : Ground Water at 3 feet Soil Not Suitable for Soil Absorption USE HOLDING TANK Number of Bedrooms 5 Minimum size holding tank 2000 + 500( 5-3) = 2000 + 1000 = 3000 gal USE 4000 GAL Based on pumping capacity of 3500 gal per load Ground water at 3 feet. Up lift on tank when empty: 4000 x 8.35 = 33,400 Ib Weight of 4 feet of gravel back fill 125 x 6 x 4 x 17 = 51,000 lb Safety Factor against Flotation: 51000/33400-1.53 OK The installation of this holding tank will not prevent development of adjacent lots. . The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. a 0 0 H J I I I I II I I II LOT 1 I � \ \ � �. LOT IA I LOT 3A I I � 1 LOT 10 �1� LOTS 1 1 1 1 \ LOT 4 I I I OF I I .�P(E.......• ��y� \ c. ,. % �♦i 49th -I I ri iD 3EN SPURKLAND•.� No. CE -2225 ° : 50 0 50 100 150 200 250 300 %�a` •. _.•`cam SCALE; 1' = 100 FT, 03IUMILNP1 31-UKALAIVU AVENUE P.L. I I L 0 T 3 CARR SID I I SEPTIC SYSTEM DESIGN ANC . K. 9 AVENUE DOUGLAS NESS DATE. • OCT. 30.1999 (NCH. AK. 99501 11561 HILLSIDE DRIVE SHEET. 1/3 GRID: 2640 (907) 179-3916 � PERMIT # SV990XXX PID # YY CAR00031.DVG I I � — I A - tix x I I k I I I I 1 I I 100 FT. MINIMUM 1 I k II I CLEAN OUT I I 1 I I 4000 GAL. HOLDING TANK O o . ----- -- - - -- - - - - -- NPUMP ABANDON EXISTING SEPTIC TANK IN PLACE AND CLEAN, FILL WITH LEAN CONCRETE i- ....i.....49t.....«....«.... ...� 0 i......1» .. ...............«.......... = TDB $N SPURKLAND i �1� fes•.,• No. CE -2225 r•.'•�� I 4.�OFESSVN'. ��� SCALE., I' = 50 FT. [08dLN 5PUHKLAND P.L.SEPTIC SYSTEM DESIGN 203 V/ 15TH. AVENUE LOQ' L��kK SID ANCH. AK. 99501 DOUGLAS NESS DATE: OCT. 30,1999 (907) 279-3916 11 11561 HILLSIDE DRIVE SHEET. • 2/3 GRID: 2640 PERMIT R SV990XXX PID H YY CAR00031.DVC 4—FT BURY RAIN CAP T 6' PUMP AC BACKFILL WITH SAND AND GRAVEL I' X 10' CONDUIT I' GALVANIZED LB. DIRECT BURIAL WIRE TO ALARM PANEL ---F 1' PVCLu CUNDU/ HIGH WATER ALARM / MERCURY SWITCH FL AT 18' 75.5' 17' STANDARD 4000 GAL, HOLDING TANK P��. ..•...,, ♦♦♦♦ ANCHORAGE TANK ri7,e ♦j NO SCALE s 49th lr st It EN $PURKLAND j No. CE -2225 t � B£NCH MARK. ASSUMED ELEV. 100.00 £T. ITOBBEN SPURKLAND F.E. I I LOT 3 CARR SID I I SEPTIC SYSTEM DESIGN 6751 W.. 9950 BLVD. DOUGLAS NESS DATE: OCT. 30,1999 ANCH. AK. 99502-3904 <gn7> Peo_cnoc 11561 HILLSIDE DRIVE SHEET: 3/3 GRID: 27J6 �SI'/990XXX PID YY CAR000JJ.DV/GI/990XXX PID YY CAR000JJ.DVIG I PERFORMED LEGAL DESCR 1 2 N- 3 7- 4 5 6 7 8 9 10 11 12 13 14 15 16 17 16 19 Munl:lEaflly of Anchorage DEPARTMENT OF -IEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST das�-0- Sold-liez LL.141 � r�vC f3 UAA-- FH vi - Ile -4..'P&4t-cr i- r,, ea• •1 'z 6) '.{ENGINEER'S SEAL)':', • � � :.. � ............. T. DATE PERFORMED: ' RIEcI99 ' Township, Range, Section: IF YES, AT WHAT OePTH7 Oe;..h to Water Atter Irvilorinp7 JITt PLAN mmmmmmmmmm ■■■■■■■■■■ 20 -{ IL.— JI PERCOLATION PATE (m,nulevmcn) PERC HOLE DIAMETER TLST RUN BETWEEN FT AND FT DISCLAIMER• Groundwater rnnditinne indirated are fnr the datPe shown only. Past and future presence i.nd/or depth of grolndwater can not be predicted from these o s,ecv tions. PERFORMED BY: — �- ___ 1 1 . _ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUI: ELINES IN EFFECT ON THIS DMF. DATE: - to -2-q " Tr 72.008 (Rev. 4/85)  MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAl. PROTECTION ENVIRONMENTAL ENGINEERING DIVISION ,, I 825 L Street- Anchnrage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME PHONE [] NEW MAILINO~DDRESS LEGAL DESCRIPTION I Well I Absorption area D~lling PERMIT  Manufacturer Material No. of compartments Liq. capacity in gallons IF HOME.DE: Inside length Width Liquid depth ~O ~ DISTANCE TO: Well Dwelling PERMIT NO. O z ~ Manufacturer Material Liquid ca.city in ~llons ~ Well Poundation Nearest lot hne P~RMIT NO. ~ ~ DISTANCE TO: O~ ~ Top o~ hie to finish grade ~ ~ ~a~eria} beneath tile . ~ inch~ TotaJ ef~i~ ~/abs°~t~°n area m Well Building f~ndafion Nearest lot line ~ DISTANCE TO: ~ Building foundation Se~r line Septic tank Absorption area(s) ~ DISTANCE TO: OTHER , ~ ~ PIPE MATERIA~ ~rg~Z APPHOVED DATE LEGAL PERMIT NO. HUN I C: I PAL I T¥ OF I:INCHURI=IGE -~' DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 'L' STREET, ANCHORAGE, AK. ~501 264-4720 ON--~ I TE ~EI~ER PERM I m ( 800085 ) APPLICANT LOCATION LEGAL DAN P. HUC~RBRY HILLSIDE DR. TYPE Of SOIL ABSORPTION SYSTEM ~610 HAZEN, IS: DRRINFIELD ANCH. LOT SIZE ~49-5264 5~560 SQUARE FEET MAXIMUM NUMBER Of BEDROOMS = 4 SOIL RATING THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: DEPTH= DEPTH= ::~ THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAINFIELD. THE DEPTH OF R TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET). THE TRE~4CH WIDTH I~; 5. ~0~ FEET. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM Of THE EXCAVATION (IN FEET). REQU I RED :~EPT I ¢ TAt4K S I ZE= '1250 Gi:ILLO~I$ PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE NELL WILL SERVE. ------ Tt~lO ( 2 ) I NSPEC:T I O~,lS liRe REQU I RED BACKFILLING Of ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 190 FEET FOR A PRIVATE WELL OR t50 TO 200 FEET FROM R PUBLIC NELL DEPENDING UPON THE TYPE OF PUBLIC NELL. MINIMUM DISTANCE FROM R PRIVATE WELL TO A PRIVATE SEWER LINE IS 25 FEET AND TO R COMMUNITY SEWER LINE IS 75 FEET. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. I CERTIFY THAT l: I RM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS RS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. ~: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN 4 BEDROOMS. ~IGNED: ~~ ' ISSUED B~_~___ DR 'E-~/-~t~-~- V4.~ .RE REID ENVIRONMENTAL ENGINEERING SRA BOX $584R ANCHORAGE, ALASKA 99507 SF'ECiFTCATIC. NS?-!b 7- <AE:AY (907) 344.-1205 PACE 1.0 GEN:E~AL 1.1 The drawings, sheets i thru 4 sh,~il be a Pert of this specification. 1.2 All materials end work~anshi~ shall mee'C the approval of the AnchoraGe De~t of Health ant Environmental Protection ~ermi'to Z.O LiFT STATIO~ 2.1 ~11 eIec~rzcal fittings end connections in the lift station sh~ll mee~ NE~ ~eouirene~ts for a' water tight se~viceo 2o~ There shall be e hish level alarm set e~ the level of the existin~ soil Pipe fro~ the septic ta~ko The buzzer sh~ll be located in a weather tight enclosure adjacent or inside the e~istin~ electrical entrance near the 2o3 The sump Pu~,P shall be capable of delivering 1~ GP~ at a hemd of 20 feet. 2,4 The sump P~,P small be s~sPended not less than & inches off the bottom of the lift station with a chain or n~lon line. ~.5 The ~4' Pipe for the lift station shall have a water ti~hb sealed bottom. 2o& The to~ ca~ shall be rain tioht mhd securel~ fasteneO with screws, ~.? All Penetration of the lift station Pipe shmll be water tishto 3.0 SEEPAGE BED · 3,1 The ~ravel for the bed shall be screened to the sizes inoiceted0 3,2 The sand shall have an.e'rfeo%ive size of 0.4 TO M~, and m uniform, itu coefficient of not more then 3.3 A one foot cle~ seal shell be installed or, the sloped sides, of the excavation° It shall be well con, Packed+ 3.4 The bottom, of the cxc~vation shell be raked with the bacEhce blade to ir, sure tha~ the botto~ hms not conPacted d~in~ the excavetior,, The bottom elevation shall be + or - 3,5 The 1' distribution Pipes sh~ll be rioid PVC or Pol~eth~ler, eo Holes, 1/4 ' in diameter end spaced at ~4' cen~ers shell be Orilled ~lor,~ the Pieeso The hemdor Pipes sh~ll not be drilled, 3,& A heat trace line shall be run alor,~ the side of the distributzon Pi~e~ next to the drive, ThetaPe shall be taped to the sides of the PiPe,The tape shell be Chemelex, 4ATV1, or eeuelo Retino is 4 Wefts Pea foot at 1leV. MUNICIPALITY OF ANCIIORAGE lle~''''''%, and Environmental Prote"'Ron Fourth Floor West 825 L Street Anchorage, Alaska 99501 279-2511, x 224, 225 LOCAT,ON LEGAL SEPTIC TANK: DISTANCE FROMWrLL !Oo INSIDE LENGTH COMPARTME~S INSIDE WIDTH ~ LIQUID DEPTH ~ LIQUID CAPAClTY%~OGALLONS. TILE DRAIN FIELD:-'~'''~tl~-~u'¢-~ DISTANCE FROM WELL ~ ~O FOUNDATION NEAREST LOT ~ OF LINE ~ ~ DISTANCE BETWEEN LIt;ES ~/~ TRENCH WIDTH ~IN. TOTAL EFFECTIVE ADSORPTION AREA ~0 ~ SQ. FT. LEITH OF EACH Lira/ ~t DEPTtl OF FILTER DEPTIt: TOP Or TILE TO FINISH GRADE MATERIAL BENEATH TILE /0~IN. ABOVE TILE ~ I~. SEEPAGE PIT: DIAMETER OR WIDTH Log Crib Rings/cRIB SIZE: DIAMETER BUILDING FOUNDATION NEAREST LOT LINE LENGTH DEPTH DEPTH__ DISTANCE FROM: WELL TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) SQ. FT. Well ~- Class:it~. Depth: Well Di-~nce To: Lo~ Line Bldg: 10I~ Sewer Line: Pipe Materials:CI~L~k~~ ~ of Bedrooms: Installer: ~0~ q Remarks: ~':'7~1 DATE c;h'-\~-'T"t APPROVED . Well Log ~,o~o~..~~.. ~..~.~.....~..~,.~...~~. ~.<~., 'Da~.e completed......~.~..~.~. ;.. ~...~?.z ./...~..ff.~... ................... ................................. ~:P~h of we11...,...~.~..~.~ .......... : ........................................................ s~,~ o~ ~ .~...~. ................................... D~e ~o ,~e~.'~~ ...... ~-~..~ .......... )~t~ce to water while p~plng...,~....~ ...................... ~t rate o~ ..... ~.~ ......................... ~uo~ p~ ho~. I ~rom { tO Driller DELTA DRILLING COMPANY HrFl I [.nN1 I_I:I[:A T ) 13N H1 .... :,ILL DRIVF L.--~ _.rtf~K .... IIL KHTINJ <S~ FT/F;R)= J.,-..., ,'1: RE[~LIIRE[) _I,:'.E I],- TIqlE '_g;llIL ~F;S;3RPTION=,'r=,TErl'-'"- ' IS: 'IHC LENGTH [)IHEN'SI£1N IS; TH~ LENGTH (IN FEET) OF THE TRENCH CiE: DRHIN~-IEI.D. THF: DEPTH i-~F' ~ IR'ENCH OR PI1 IS THE DISTANCE E:ETNEEN TFliZ SURFACE OF THE ';H;{~'E ~!, NFl SKT WIDIH FFI;¢ IR'.FNCH~{S lHE G;'F~VEL D~F'TH IS TH;Z IIINIHiIH DEPTH OF GRAVEL BETWEEN THE OUIFAL. I.. PIPE ~ND IHE BOITOH OF 'TH;: E)3CFI'dATICiN (IN FEET). F' t:; I:: I (: i:i 13 I_-~ F' I_ Fi l'-J 1" I:I F' T Ft PIRC:I.3--iGE F'LFINI' MFi',' E',E ]II%TFII.LI--_D FIT THE F'ERi'IITIEE'S OPTIClhl Si_.IF;JEC1 TO 1HE FOLI_[Y,.,I I Ni_-i Ii:I:IN[) I T ] CINS: t. Ell'tlf{R F~ CI_FI-'5..S I Ol;~ Il NSF I:IPi:'RO',,,'E[') F'I_I-tNT g CFINTINUFiI.rF_, Ht~INTENi~N;;:E FtGK'EEHEN~ IS; RE~U[RED. IF ~ HFtINTENFtNCE RGRF[EIIIEI-'I IS hh:iT t-~EF'I' C:IIp~'REi',!I YOU HFt',' BE REiS)IIIRE[:, TO ENLARGE 1HE SOIl_ AF:SI]F<PTION SYSTEI'I FiNF)/13&T YOU I. tFIY lie SI_IB._IEC1 lO PROSECUTION. IIINIHLI;'I E)ISI'ANCE DETNEEN FI IqELL gNO ~N',' ON-SITE SEHI~GE DISPOSAl_ SYSTEIi IS I~o FEET FFli~ F* F'RIVFtTE NELl_ OR 2~A FEET FCIR A PI_IE;LIC NELL. L.J~LI_ LOGS GR~ REQUIRED ~NO HI.IST F;E R'ETLIRNED TO TH~ DEPARTMENT NITHIN 3A DRYS I]F TIi[{ N;:LL F:gHPI.~ETII-IN OTHI{N ~'Ei~IIIg'FHENFS ~1~'~' ~PPI_Y. '$F'ECIF]CFITIONS FIND CONSTEJ. JCTION D~FIGE'~M'5 ~R'F AVF~II HF-N_E TEl INSIIRf: PROPER INSTFfl._I.ATION i ;ERTIF',' THAT :]: [ tim FII, 111.IHF, NIlH THE REFJLITRFFlhENTS FFI,~ ON-SITE c. F-O~?IH B'¢ T[hE I.lilMICIPALITY OF ANT;HDA'AGF ~' I IIFKJFRSTANF) TH$1T TH~ ON-SIIE SFWER SY'STEH HAY RECJI.JIRE ENL~'GEMENT IF T~I,~ RESI[,ENgE IS REIIOOEI.ED TO INCII.D~ I'IOI{:E THI~N 4 MATERIALS TESTING · QUALITY CONTROL SOILS ENGINEERING 2204 ClevelonCl P.O. Bo~ 10-1126 Ancho~ege~ Al(. 99511 277- 710 Third Ave P.O.. Box 2540 Fairbanks. AK. 99707 452-1267 · 456-51=...5 Hole N o. Location TRENCH ~1 Sheet 1 of 4 ; W.O. No. 80-1326 Operator Date 23 April 1980 see plot plan .Top Elevation Unknown Client Mr. Dan Huckaby Project Residence on Hillside Dr. Depth Classification Sample Legend Feet System Data C,R,~.Y ~TT,TY CLAY Grovel BROWN GRAVEI.L¥ SAND Sand lB0 SF per Bedroom BOTTOM OF TRENCH Cloy 0rgonic Content . ......... 22.~ ~j~ James R, Ping,ad ;. ~ Frost H01e No. TRENCH ~ 2 Location see plot plan .Top Elevation Unknown 2204 Cleveland ,~ve. P.O. Box 10-1126 Anchorage, AK. 99511 277 - 0251 710 Third Ave. RO. Box 2540 Fo[~bonki, AK 99707 452-1267'456'5155 Sheet 2 of 4 W.O. No. 80-1326 Operator t~_ ~;~,,~ic~ Date 23 April 1980 Client Mr. Dan Huckab¥ Project R~dence ,,n !!i!!side Dr-, Depth Feet I. 2. .. 12. 13.- 14.- 15. 16. 17.. 18. 19. 20.. 21. 22. 23. 24. 25. 26. Classification System Sample Data BROWN PEAT GRAY SILTY CLAY BROWN GRAVELLY SA~D BOTTOM OF TRENCH NOT ACCEPTABLE FOR SEPTIC SYSTEM Legend Gravel Sond Silt Clay Organic Content Peat V,'6t e r MATERIALS TESTING · QUALITY CONTROL SOILS ENGINEERING 2204 Cleveland ,~ve. P.O. 8ox 10-1126 Anchorage, AK. 99511 277- Ct'S1 710 Third Ave P.O Box 2540 Fairbanks, AK 99707 452-1267-456-5155 Hole N o. Location Trench ~3 Sheet 3 of 4 ~0. No. 80-1326 Operolor R. Date 23 April 1980 'Rem ~lnf ~lnm · ,'Fop Elevation Unknown Client Mr. Dan Huckab¥ Project Residence on Hillside Dr. Depth Classification Sample Legend Feet System Dote 2. 5 Black Peat Grovel · ?o Bottom of Trench Clay NOT ACCEPTABLE FOR SEPTIC SYSTEM Organic Content ,.% MATERIALS IF_STING · QUALIIY CONTROL ,SOILS ENGINEERING T-ITT,T.~ TBE DR'TVIFt T TRENCH 3 TRENCH 2 /~ CLEAN-OUT FOR SEPTIC TANK NOT DR, A}~I TO SCALE SHEET 4 OF 4 Performed For Dan Huckabay Lenal qescrintion: Lot 3 Block This form Renorts Soils Lon yes 2204 Cleveland Anchorage, Alaska 99503 Date Performed 6/13/77 Subdivision Carr Percolation Test Tenth Feet Soil Characteristics 4-- 6-- 10-- 12'-- 14--. 16-- 18 20 Peat (some surface water) Grey Sandy Silt Brow~ Sandy Gravel Bottom o: Test hOle Was Ground Water Encountered?.No I¢ Yes, At what Denth? i-.-J I J i~ t I ~ I I. Readinq Date Grnss Time Net Time Depth to H20 /let Dron i I I · Percolatinn Rate fiinute Prnrosed Installation: Seenaae Pit Drain Field Deoth of Inlet Denth To Bottom Of Pit Or Trench CAU!'ENTS: 125 sq F~'~ldrainaqe area required per bedroom from -5 to 12 feet. Test PerformedBY~ Data Certified B~CONSTRUCTION TEST ~ - David Paul ~ Date: 6/13/77 MUNICIPALITY OF ANCHORAGE ,1 Development Services Department `r ` ') Phone: 907-343-7904 On -Site Water & Wastewater Section �- Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I. D. 015-163-78 1. GENERAL INFORMATION Complete legal description Location (site address) CARR LT 3A 11561 Hillside Dr Expiration Date: ��/2.d Current property owner(s) SECRETARY OF VETERANS AFF Day phone 240-2474 Mailing address Real estate agent 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF' BEDROOMS: 5 4. TYPE OF WATER SUPPLY: Private Well 0 Water Storage . ❑ Community Well ❑ Public Water System ❑ Waiver request for: Received by: Day phone 578970 `/ � '�'U V 12 2019 a 0z69L9�h w TYPE OF WASTEWATER DISPOSAL: _ Private Septic ❑ Holding Tank 0 Community ❑ Public Sewer ❑ COSA to be released to the engineer, unless otherwise requested by the engineer. Date: COSA Fee $ 5_56 Waiver Fee $ Date of Payment 11 113 IN Date of Payment Receipt Number 031 dab Receipt Number COSA # 0 q 15Q3 Waiver # Distance: 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm NorthRim Eng. Phone 694-7028 Address PO Box 770724, Eagle River Engineer's Printed Name Steve Eng Date 11/12/19 k'a 6. DSD SIGNATURE n �� + C:� System #1 Approved for .5 bedrooms W System #2 Approved for bedrooms `` , steYc:, S O Y pp Gia" PE v Disapproved ��� O o Conditional approval for bedrooms, with the following stipulations''` .�ttlll(tttttt�,, WASTEWATER z� � PROGRAM \fig )))))111 By:Original Certificate Date: , 4-4The Municipality of A orage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations gi n in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist Septic System Advisory Well Flow Advisory COSA Checklist blue sheet X Nitrate Advisory, . Arsenic Advisory ' Other Legal Description: CARR LT3A If more than1septic system onlot: 'C0SAChecklist #of A. WELL QATA RE Well log is filed with Onsite (or 8112/77OabadhUad Parcel ID: O15-163-78 Structure served bythis system Well production at time of test 8+ .pm Water storage tank volume 0 gallons Total depth 66 ft Well disinfected for coliform test? E] Yes XNo Cased to 06 ft XColiform bacteria koNegative FE -1 Sanitary seal is functioning correctly Nitrate 0-8 mg/L F-1 Nitrate less than MRL (NO) Wires are properly protected /\raenicug/L XArsenic less than MRL (ND) Casing height (above ground) 36 in. Collected by NRi[nEnQ Date nfflow test for CC)G& 1118«9 Date ofSample 1012V Static water level mtbeginning oftest 12 ft, Comments Well artesian- K4QA records indicate as artesian. Not artesian -flowing during test. B. TANK DATA 81 -of years Tanktype/mohaho| HT/steel " Measured operating fluid level inseptic tank 52 01Standpipes/foundation cleanout per record drawing Date of pumping 1117Y19 D. ABSORPTION FIELD DATA Which system tested (date ___ MALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth topipe invert from grade _ft (min) El N/A — pressurized field F-1 Monitor tubes @ntnbottom ofeffective. Ifnot, state depth into effective _____ F-1Code-required soil cover over field MSystem presoaked (Required ifvacant for greater than 3Udays prior ho date of Gallons introduced gaUnno Comments/Deficiencies: COSA Checklist yellow sheet C. LIFT STATION F1Required maintenance completed Age oflift station ____years Lift station mohaha| Adequacy test date Results F—lPaaaFor bedrooms Fluid depth prior to � in ' Water added, _gal New depth in Elapsed time __rnin Final fluid depth in Absorption rate gpd Any rejuvenationtreatment (past 12months) If yes, enter date E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' 0 Yes Community Sewer Manhole/Cleanout > 100' C j,�„ Yes if No ft M Yes if No ft Neighboring Tank > 100' ❑✓ Yes if No ft Private Sewer/Septic Line > 25' ❑✓ Yes if No ft Absorption Field on Lot > 100' 21 Yes if No ft Holding Tank > 100' Yes if No ft Neighboring Absorption Fields > 100' �M Yes if No Animal Containment > 50' Yes if No ft Yes if No ft Manure/Animal Excreta. Storage > 100' Community Sewer Main > 75' [Z] Yes if No ft M Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' FV_1 Yes if No ft Surface Water> 100' ;D Yes if No ft Property Line > 5' 0 Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' 7 Yes if No ft Private Wells > 100' F-71 Yes if No ft Water Main > 10' ❑ Yes Yes if No ft Community Wells > 200' Q Yes if No ft Water Service Line > 10' Yes if No ft if septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Yes if No ft If absorption field is under driveway comment below Property Line > 10' ❑ Yes if No ft Wells on Adjacent Lots: Water Main > 10' ❑ Yes if No ft Private Wells > 100' Water Service Line > 10' ❑ Yes if No ft Community Wells > 200' Surface Water> 100' ❑ Yes if No ft F. ENGINEER'S COMMENTS Holding Tank Alarm Confirmed By A+. Tank is Holding Tank -Steel. e7-. E G. ENGINEER'S CERTIFICATION 1 certify that 1 have determined through field inspections and review of Municipal records that the above systems are in conformance with MOR COSA guidelines in effect on this date. COSA Checklist yellow sheet Yes if No ft ❑ Yes if No ft Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program / 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 I Q� www.muni.org/onsite (907)343.7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. O% ` 7 9 COSA# 0 9 0 Z 1. GENERAL INFORMATION Expiration Date: _� - R — / 0 Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address CARR LOT 3A 11561 HILLSIDE DR. 'ANCHORAGE. AK DOUG & FLORA NESS Day phone C/O AGENT Community On-site ❑ Public Sewer 11561 HILLSIDE DR. *ANCHORAGE. AK Day phone MICHELLE DROEGE W/ PRUDENTIAL Day phone 230-3372 3801 CENTERPOINT DR. #200 *ANCHORAGE, AK 99503 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 5 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ TYPE OF WASTEWATER DISPOSAL: Individual On-site ❑ Individual Holding tank Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered In the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also Issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Finn GARNESS ENGINEERING GROUP, Ltd. Phone Address 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines d Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory lest results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the ownerlisted above. Any reliance upon or use of this report by any other person or party Is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE Approved for 1-5— bedrooms. Disapproved. Conditional approval for Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory Date bedrooms, with the fllowing stipulations: f/ Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report' Other 337-6179 = ••.ON-SITE • : WATER AND WASTEWATER : PROGRAM By: (lw. / ""6-e� Original Certificate Date: (Rn. 11105) Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343.7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: CARR LOT 3A Parcel ID: O ljf�- / 61':5 - 78 A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID# N/A Date completed 8/12/77 Sanitary seal (Y/N) YES Total depth 66 ft. Cased to 66 ft. FROM WELL LOG Date of test 6/12/77 Static water level ARTESIAN ft, Well production 8 .. -g•p.m. WATER SAMPLE RESULTS: Well Log (Y/N) YES Wires properly protected (Y/N) YES Casing height (above ground) 12+ in. AT INSPECTION 4/28/09 ARTESIAN ft, 2.19 g.p.m. Coliform 0 colonies/100 ml. Nitrateod 3mg./L. Other bacteria 0 colonies/100 mi. Arsenic:�5_ug./L. Date of sample: 1/29/2010 Collected by: GEG Ltd. B. SEPTIC/HOLDING TANK DATA Tank Type/Material STEEL/HOLDING TANK Date installed 8/20/2000 Tank size 4000 gal. Number of Compartments ? Cleanouts (Y/N) YES Foundation cleanout (YIN) YES Depression over tank (Y/N) NO High water alarm (Y/N) YES Date of pumping AS REO'D Pumper ISAACS PUMPING C. ABSORPTION FIELD DATA Date installed Soil rating (g.p.d./feor ft'/bdrm)_ System type Length ft. Width ft. Total depth ft. EH. absorption area_ ft' Monitoring It Date of adequacy test Results Gravel below over field For bedrooms Fluid depth in absorption field before m-! in. Water added _gal. New depth _in. Elapsed Time: . • Final fluid depth _ in. Absorption rate >= g.p.d. Iuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date - "HOUSE HAS BEEN VACANT SINCE APRIL 2007. D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N 'Pump on" level at in. 'Pump off" level High water alarm level at in. Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot N/A On adjacent lots 100'+ Absorption field on lot N/A On adjacent lots 100'+ Public sewer main N/A Sewer /septic service line 25'+ Animal containment areas 50'+ Public sewer manhole/cleanout N/A Holding tank 75'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 100+ Surface water 100'+ Wells on adjacent lots 75'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line Water service line F. COMMENTS G. ENGINEER'S CERTIFICATION Building foundation Water Surface water on adjacent lots I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date z / /to COSA Fee S C Date of Payment ,1A. > Receipt Number 0 6 % Y' (Rev. 1 troy) Waiver Fee $ storage Date of Payment Receipt Number Municipality of Anchorage _- F I -tel Development Services Department4 4. l Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsiteonsite (907)343-7904 'CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 015-10-7?) COSA# Qq O217 / 1. GENERAL INFORMATION Expiration Date: f d - / G - � Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address CARR LOT 3A 11561 HILLSIDE DR. *ANCHORAGE. AK DOUG do FLORA NESS Day phone C/O AGENT 11561 HILLSIDE DR. *ANCHORAGE. AK Day phone MICHAEL DROEGE W/ PRUDENTIAL Day phone 230-3372 3801 CENTERPOINT DR. #200 *ANCHORAGE, AK 99503 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 5 3. TYPE OF WATER SUPPLY: Individual Well ❑ Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ TYPE OF WASTEWATER DISPOSAL: Individual On-site ❑ Individual Holding tank 0 Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered In the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF 114SPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage riles and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Finn GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SURE 101 • ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineers Comments: in conducting this evaluation, GEG, LID. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily Identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE _1� Approved for bedrooms. Disapproved. Phone 337-6179 Date -I 1 0ci :. .............. .J fry ess; CE-79;jJb� P9.cgo� Conditional approval for bedrooms, with the flowing stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory t/ Arsenic Advisory Maintenance Agreements Supplemental Engineers Report Nitrate Advisory I `Other By: f— tae.. nmst a4��tttttllrrr ri OF4, , QP ' S� yo' _ ON-SITE •'•��; WATER AND WASTEWATER PROGRAM ' Original Certificate Date: 7— n - 0 1 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.orglonsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: CARR LOT 3A Parcel ID: O 1S C 3- 7 S A. WELL DATA Well type MATE If A. B, or C provide PWSID# N/A Well Log (YIN) YES Date completed 8/12/77 Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES Total depth 66 ft. Cased to 66 ft. Casing height (above ground) 12+ in. FROM WELL LOG AT INSPECTION Date of lest 8/12/77 4/28/09 Static water level ARTESIAN ft, ARTESIAN _ft. Well production 89.p.m. 2.19 g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 ml. Nitrate 0.124 mg./L. Other bacteria 0 colonies/100 ml. Arsenic: 0 ug./L. Date of sample: 4/27/09 Collected by: GEG Ltd. B. SEPTIC/HOLDING TANK DATA Tank TypelMaterial STEEL/HOLDING TANK Date installed 8/20/2000 Tank size 4000 gal. Number of Compartments 1 Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (YIN) NO High water alarm (Y/N) YES Date of pumping Pumper ISAACS PUMPING C. ABSORPTION FIELD DATA Date installed Soil rating (g.p.d./ft'or ft'/bdrm)_ System type _ Length ft. Width ft. Gravel below i r� ft. Total depth ft. EH. absorption area_ ft' Monitoring tube' Depression over field Date of adequacy test Results P all) For—bedrooms Fluid depth in absorption field before _ in. Water added gal. New depth _in. Elapsed Time:Final fluid depth _ in. Absorption rate >= g.p.d. uvenation treatment (past 12 mo.) (YIN & type) NONE KNOWN If yes, give date — **HOUSE HAS BEEN VACANT SINCE APRIL 2007. D. LIFT STATION Date installed Size in gallons "Pump on" level at in. "Pump oft" E. SEPARATION DISTANCES Manhole/Access water alarm level at in. Cycles tested Meets alarm & circuit requirements? SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot N/A Absorption field on lot N/A Public sewer main N/A Sewer /septic service line 25'+ Animal containment areas 50'+ On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout N/A Holding tank 75'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 50+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 75'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line Building foundation Water Water service line Surface water on adjacent lots F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date -7.1106-1 COSA Fee $ ��9D . Date of Payment o Receipt Number 16 3 a 93 (Rev. 11/05) Waiver Fee S storage Date of Payment Receipt Number 1 v S CU'f Ul N C0b1'26" v; ! 1 •� N k. • • a W . \ 1'26" E� 1 V QOM _J 14' :0 w .ice ♦S.'' a/� a. N C0b1'26" v; tO' CCA EASEMENT N OO'01')7' w 16� I HILLSIDE 0 A ! 1 •� N k. • • a W . \ 1'26" E� 1 14' w .ice ♦S.'' a/� a. :I M e F �aln��Ii�:fi V / 15. WYf� pPp ra�� I N f tT�F-e e_ rQ�.'vll- wc YW7 1#\ � Vi �apOw 1 i vlrF�_ 1'1 VIF WFS W r E!s Q I''oQo�a f W 4 W H y 4 l; o 1— is J W y LL O n 4 J j J =U�w Wf�J �Ip u=al_ W = Q �}Y WRQ"Y"C II tO' CCA EASEMENT N OO'01')7' w 16� I HILLSIDE 0 A ! 1 � �G e4ol w DRIVE w 's :I M N �aln��Ii�:fi V WYf� pPp ra�� I f tT�F-e e_ ='a E!s f ISFa l; o zfiii�e efi \ !i.. �}Y II Pr _>EEZyE ��c �.a z351dsab. _I I u V) I a ; v 41 a W ! Q W b, j pi ~ I Z) t,}1 I r V) 4' IoJ III In j Qt,,D DRIVE ~ PLEASE HAKE ALL CONTAC~HRU REALTOR: ELLIOT LAWSON AT~K I~tITE C~O...~.(2.77-1553) '~'~ Send all correspond~ to abo've agent also .... MANY ~NKSII! ~S L SWm - A~or~, ~ ENVIRONMENTAL ENGINEERING DIVISION 1. pRO~R~Y~NER I PHONE Dan ;. & 3amte A. Huckabay I 349-5264  MAILINGADDRESS S~ SOX 257~::; Anchotase, AK 99507 ~OPERTY RESIDENT (If dif ferent from ~o~) PHONE ~. &Nts. Hatvtn Sp~uak none a~ this t~e ~ BUYER ~t~t~ [~O ~ PHONE Mr. & Mrs. Marvin Sprunk %-%~-: MAILING ADDRESS S~ Box'~2572~ Anchorage, AK 99507 Alaska National Bank of the North ~%~ ~ 27~4581 MAILING ADDRE~ ('~, ~EALTOR/AGENT ,L,NG ADDRESS 3301 C Street, Anchorage, AK 99503 Jack White Co. (ATTN: ELLIOT LAWSON) PHONE 277-1553 3201 C Street, Anchorage, AK 99503 E. LEGAL DUCAI~TION Lot 3, Carr Subdivision STREET LOCATION Hillside Drive (East side of Hillside)...approx. ½ mile south of Q'~4,11o_v Road. Home is beautiful redwood sided structure aoorox. 200' e. TYPE OF RESIDENCE NUMBER OF BEDROOMS ~ Hil3 [] One J~ Four~~ [] Other ~ SINGLE FAMILY f--I Two ~-~ I~1 MULTIPLE FAMILY [] Three 7. WATER SUPPLY INDIVIDUAL* COMMUNITY [] PUBLIC UTILITY 8. SEWAGE DIS -Fi~-&L SYS~TEM INDIVIDUAL/ON-SITE** PUBLIC UTI LITY ACH WELL LOG. A well Io~ is requi'red for all wells drilled since June 1975. For wells drilled prior to that date, g'~ hell , depth (attach log if available.) ~ L.~- t~::~'~ '"J~l.~J '~' 'elf i'ndivldual/(~n-site, give installation date ~1~"[---~4 ~ ~ ~"~ If system is over two (2) years old an adequacy test is required by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. off ;ide Dx 72.010(3/78) · .' THIS SIDE-FOR OFF'ICIAL USE ONLY DATE RECEIVED '. INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE iNSPECTOR INSPECTOR INSPECTOR DIRECTIONS: 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [--I SINGLE FAMILY [-I ONE I--I THREE I-'1 FIVE [] OTHER I-'1 MULTIPLE FAMILY [] TWO [] FOUR [] SIX 2. WATER SUPPLY PERMIT NUMBER ~ . [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY ' Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER [] INDIVIDUAL/ON -SITE DATE iNSTALLED []PUBLIC UTILITY ~--~ -[ Connection Verified INSTALLER []Septic Tank or [] Holding Tank Size: I ~,:~"O If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL - Absorption Area to nearest Lot Line - [~ONDITIONAL APPROVAL (letter must acp6ml~ny certificate) LEGAL DESCRIPTION ~. , 72-010 IRev. 3/78) -~ ,..,I~IUNICIPALITY OF ANCHOR ..... ~ ~ /o/~L ~//~-~], . DEPARTMEN' iF HEALTH AND ENVIRONMENT,r--! ROTECTION ,.~,:~.~ · ; C~%,~I ~ Time Date ~-~Q~ ~D~ Date ~(D-~-qQ Date Insp [30,/% Insp ~~ Insp REQUEST FOR APPROVAL OF INDIVIDUAL SEWER AND WATER FACILITIES Lending Institution Request: Security National Bank % Chris Anderson Mailing Address~ 880 H Street, 99501 Phone: 276-6800/18 Property Owner: Mailing Address: Robert/Lanore Carr Phone: 3. Legal Description: 4: Single Family Residence: (~ Multiple Family Residence: ( Lot 3 Carr Subdivision ', .... Number of ~e~roo~ns: ) Number of Bedrooms: Well System: Permit # Construction Individual well ( ~ Community/Public System ( ) Depth of Well Well Log on File Bacterial Analysis Sewage Disposal System: On-site System ~x) Public Utility ( ) Permit ~ Installed ~ ~ ~ Installer ~uc~ ( ~, Septic Tank Size .~ ~GC~ Manufacturer ~ Absorption Area Soils Rate ~ ~ ~-- Material 7. Distances: Well to Septic Tank to Absorption Area to Sewer Line Nearest Lot line Absorption Arca to Nearest Lot Line MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 2510 East Tudor Road, Anchorage, Alaska 99504 276-2221 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER and WATER FACILITIES 1. Type of Inspection: CMRO VA ' FHA 2. Property Owner: Robert and Lahore Cart ~.n t:[tle Mailing Address: 3. Name of Buyer: Dan and Jamf. e Ruckabav Mailing Address: 411 1~. &Sth ~'~] An~-horn_~e:Alc 99504 4. Name of Lending Institution: ~,~,-,,r.l~-? Nnr'lnnnl R,~nk Mailing Address: Pm,o~ 7-777 An~.ln~rn?.~: AI~ Phone: 99510 CONV. XXX 5. Name of Realtor or Agent: Mailing Address: 6. Legal Description: Location: Lot 3 Carr S/D I,]l~t11~tde Drive Day Phone: Day Phone: 27&-7282 ** (Contact) 7. Type of Facility to be 16~pe~ed: ~/F' 8. WaterSupp .' , : Type of Supply: Public Utility o No. Bdrms. .S Individual Phone: If Individual, number of dwellings presently served One If Individu~il, depth of well, - ' Sewage Disposal System Type of System: Public Utility If Individual, date of installation Individual (on-site) XXX Chris, there has to be a $25.00 check enclosed with each request the fee schedule went into effect May 24, 1977. See attached fee schedule. This must accompany the request before we can sta=t processing. Thank you. Laura, 264-4720 Chris Anderson 9-8-77 ~ 72-003(3/76) Pa~q"'Two Department of IIealth and Environmental Protection Request for Approval of Individual Sewer and Water Facilities Legal Description: Lot 3 Carr Subdivision Affadavit Attached: '( ) Letter Attached: ( ) Disapproved: ~__~-~-- %, '~' ~ ..... ,, _' Date:~ ~epartment Worksheet: October 30, 1978 Dan IIuckaby 411 East 45th Avenue 31 Anchorage, Alaska 99503 SubJect~ Overflowing Sewage - Lot 3 Cart Subdivision This is a follow-up of our phone conversation, Monday, October 30, 1978, at 9:00 a.m. In regard to overfl=~ing sewage on the property currently owned by you. On October 17, 1978 at 1:30 p.m., eight(8) ounces of soluble liquid red dye was dropped into a four(4) inch cleanout of the septic tank to ascertain entry location of sewage into roadway drainage ditches. An initial check October 26, 1978, at 3:45 p.m. to the property r revealed penetration of dye was present around the septic sump. A further check of soils test previously taken showes two(2) feet of surface peat. Surface water obviously is being absorbed near the septic sump. Although, changing water table may be cause of the in~_--usion. I may suggest diverting surface water to street culvert and prevent absorption at sump, or an additional soils test be taken near the sump to check against the =xisting test to ascertain water table. However, the tank m~st temporarily be used as a holding tank and pumped as needed. The septic pipe nust be blanked by a cover at the outlet side of the tank until intrusion of surface water is s stopped. If there are any further questions, please contact this office at 264-4720 or at ~e above address. Thank you for your cooperation in this matter. Sincerely, Hank Allers Principal ~nvironmental Control Officer m%/ljw