Loading...
HomeMy WebLinkAboutCONIFER HEIGHTS BLK 1 LT 20Onsite File Conifer Heights Block 1 Lot 20 #015-093-56 ,by DOC Co. dba SULLIVAN WATER WELLS P.O. BOX 670272, cHUGIAK, ALASKA 99567 · TELEPHONE 688-2759 OWNER OF LAND Wall Thickness , ~.~ inches inChes, depth ,2~4 C feet LEGAL DESCRIPTION ~ ~PE~'.NUMBER~ Date of Issu~ is.well-locat~ at approved pe~it ~cation? ~ ~ No Method of Ddaing: . ~ota~ ~ ~ble tool Depth of well: 'Casing T~e · Diameter 4 ~ Casing' Stickup Above Ground: StatiC Water Level (from ground level): . Pumping level:~ R~ver Rate: MethOd of Testing: /ogP feet feet after hrs. pumping gpm /3'" .gpm Well Intake Opening Type: ~ Open End [~ Open Hole I~1 Screened; Start feet Stopped feet ~lS'erforati°ns Start '1 W~) feet Stopped ~)'i~ C3 ~ feet Grout Type:~,~?0,~ DePth: from {~ feet, to ~ feet Pump Intake Depth: feet Pump Size hp Brand Name Well Disinfected Upon'Completion? ~'% [~ No MethOd of Disinfection: C../~,,=&.J E ',v~0 ~/PR · Comments: .BORE HOLE DATA DEPTH &iAR 2.2 ,'uuu ~,;;~i;~.lp~,hty ol/~ncnorage Health & Human Driller's Name ATTENTION: it is the responsibility of the property owner to submit a copy of the well Icg to the proper authority. MunicipalityOI of Anchorage: Department Of 'Health & Human Services and/or Department of Environmental Conservation. MatSu Borough: Department of Environmental Conservation. MUNICIPALITY OF ANCHORAGE Department of Health and Human Sen/ices On-Site Sen/ices Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (go?) 343-4744 '... ~pirafion Date: Feb ~, 200~ Permit Number: SW000017 Legal Description: CONIFER HEIGHTS BLK 1 LT 20 Design Engineer: 0070 KND Engineering Owner Name: Steve and Serena O'Donnell Owner Address: 7701 Little Bend Cir. Anchorage, AK 99507- Parcel ID: 015-093-56 Site Address: 007620 LODGE POLE CT Lot Size: 30012 SQ. FT. Total Bedrooms: 5 Permit Bedrooms: 5 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. Ail requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By:~)~ ~ ! Data: MUNICIPALITYOF ANCHORAGE Department of Health & Human Services On-Site Sewer/Well PermltAppllcation q._-2- SINGLE FAMILY DWELLING Parce~ IOentffication Number NOTE:Ap~catlon must be IIIled out comHetely Property Owner Name ~) DayPhone ' : :' ' ' Mailing Address final d-l~c'~~ Cir. ZipCode Legal Description OD ! PJ'~ n ['-~ '/'~.~ ' ,nspecti~'o s~n w'~ b/e c~onducted by: ~Approved Engineering Firm [] Municipality (permit fete Included) Does your house contain any of the~ ~'follswing: [] Hot Tub [] Swimming Pool I-I Therapy Pool [] Jacuzzi [] Water Softener Unit This application Is fen [] Sewer Only '~Sewer and Well [] Sewer Upgrade [] Well Only [] Water Storage I certify that the above Information is con'ect. I further certify that ~__~.~,~ /~]p this application is being made for a Single Family Dwelling and f ~' Pm Owner/~Nell Drill ' In accordance with applicable Municipal Codes. ~'~' ~ ~' ~--'~f I Waiver Fees: Receipt I Waiver # 72-012 (Rev. 4~98)' ~[~ND ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 995YY-SY36 (907)696-6111/FAX (907)696-8111 February 4, 2000 Municipality of Anchorage Dept. of Health & Human Services On-Site Services Section P. O. Box 196650 Anchorage, Alaska 99519-6650 Subject: New On-site Sewer and Well - Conifer Hts S/D, Block 1, Lot 20 Gentlemen: The owner has requested we proceed forward to obtain a septic permit for a new septic system and well. Two testholes were dug and percolation tests conducted on May 9, 1996, through another engineer. The results of these tests are attached. The general slope of this lot is from south to north, which directs at a maximum grade of approximately 2-3%. We have designed our system utilizing the percolation rate of 17 min./inch for the four-bedroom house, which is proposed for this lot. We propose to install a 5' wide shallow trench. The first testhole percolate at 17 min./inch and the material appears to be uniform per the log and the second testhole percolated at 40 min./inch. Water was not encountered during the excavation or monitoring per the soils log. There are no public or private wells within 200' of our proposed system location except as noted. There is no surface water within 10ft of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 696-6111/FAX 696-8111. Respectfully submit, ted, I[(l"q 'iD Engineering ~s, P.E. attachments: On-Site Well and Sewer Application Wastewater Absorption System Details/Site Plan Soils Log/Percolation Test. (907) 696-6111/FAX (907) 696-8111 February 16, 2000 Municipality of Anchorage Dept. of Health & Human Services On-Site Services Section P. O. Box 196650 Anchorage, Alaska 995194650 Subject: Request modification of design for new sewer/well permit - Conifer Heights, Block 1, Lot 20 Gentlemen: On February 4, 2000, we submitted an application to you for a new well and septic. Subsequently the own.er has notified us that she wants a 5 bedroom septic system. We have modified the design to accommodate this added bedroom. Ail other items on the previous request will remain the same. Please find the attached plan-design modifications for your approval. If you have any questions, please contact me at 696-6111/FAX 696-8111. Respectfully submitted, ]III~q ~ Engineering Brent M. Western Attachments: Wastewater Absorption System Details/Site Plans WELL & WASTEWATER DISPOSAL SYSTEM DETAILS/SITE CONIFER HTS, LOT 20, BLOCK 1 PLAN ACANT TH DICENTENNIAL HILLSIDE PARK LODGE COURT VACANT \ \ % DESIGN DETAILS 5 BDRM X 150 GPD= ?50 GPD ?50 GPD/0.6 GPD P£R SQ. FT. = 1~50 SQ. FT ~50/5" X .50 R.F. (4.0' GRAVEL) ~ 125 FT. TRENCH Use 2 ~renches 6~.5' (L) x 5'(W) x 4'<D) Tot~[ depth oF system Is 8,0' From original Tot~[ depth o~ Oeave[ betow plpes Is 4.0'. NOTES: ADDITIONAL FILL ;/ILL DE ADDED OVER SYSTEM TO ACHIEVE Scare, 1'= 100' PAGE 1 DF 2 FtELD BOOKS c0a~J~ eou.o~ LANG D.A~: KMD $?AmNe LANO ~ KMD ~= LANC ~m 2/3/2000 o~ ~: ~m 2440 A~gg0g2 ~N~: 99092 (g07)GgB-6111/F~ (g07)GgG-gtll MIN. 3' COVER. PREPARED FOR~ STEVE & SERENA D'DDNNELL 7701 LITTLE BEND CIR. ANCHORAGE, AK 99507 I.~ ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 1. USE SPLITTER TO EVENLY DIVIDE FLOW INTO TWO TRENCHES. 2. USE 1250 GALLON STEP TANK. INSULATE TANK IF <4' COVER. 3. INSULATE TRENCHES V/;='' HD BURIAL FBAN IF LESS THAN 4' DF COVER. CDNTRACTBR VILL ENSURE MAXIMUM 2% SLOPE INTO SEPTIC TANK. .......... ._,L '"-.... ,¢ I, K WASTEWATER DISPBSAL SYSTEM CONIFER HTS, LOT 80, BLOCK 1 DETAILS 0 S,T, ' CD 0 0 d Pr'op TH#CASS Fie 10' UTILITY EASEMENTS PREPARED FOR~ STEVE & SERENA O'DONNFLL 770! LITTLE DEN]) CIR. ANCHORAGE, AK 99507 ~ELDBOOKS LAN G LANO ^sem.'r; LANG '~.A~nL~:g9092 0~^~: KMD o,m~c~[m KMD 2/5/2000 2440 i J~ N~= 99092 Score, 1°= 20' PAGE 2 DF 2 ]Y~ ~ [~.) ENGINEERING ~044! PTARMIGAN BLVD, EAGLE RIVER, AK 99577-~736 I (907)696-6111~/FAX I9071696-8111 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PER;ORMEO ;OR: FS~'i~q~ Ot LEGAL DESCRIPTION: DATE PE~ORMED: '~~ Township, Range. S~tion: 2- 3 4 5 6 7 8 9 10 11 12 13- 14 15- 16- 17- 18- 19- 20- WAS ¢ROU.O WATER ENCOUNTERED? SITE PLAN IF YES. AT WHAT DEPTH? 0el~ I~ Waer/Jilt . Reading Date Time Time Water Drop . PERCOLATION RATE ,Z~ {mmute~'mch) PERC HOLE DIAMETER TEST RUN BETWEEN ~ FTAND ~'~ FT COMMENTS ~,~.%~:.~.4,'~ttm~S . ALSo ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE DATE: 72-0~ (Rev. 4/85) Municipality o! Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST LEGAl. DESCRIPTION: Township· Range, Se~ion: 5 6 7 8 9 10 11 13- 14- 15- 16- 17- 18- 19- 20- SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT _ O DEPTH? rP E Maeiteri~g? Gross Net Depth to Net Reading Date Time Time Water Droo ~., ~, ( l ~ I~ ~ '~ ~ I PERCOLATION RATE I ~ .[m,nutes/mch) PERC HOLE DIAMETER TEST RUN EETWEEN ~'-.~--~ FTAND ~'~ FT PERFORMED BY: C~~ ~ I C~-u ,~ CERTIFYTHATTHISTESTWASPERFORMEDIN ACCORDANCE WITH ALL STATE AND UUNICIPAL GUIDELINES IN EFFECT ON THIS DAT~ DAT~ ~ ~ ~ ~ 72-008 (Rev. 4/85) LODGE POLE COURT N 89 56 30 E 2 I0.00' ~ T Lot 21 \ ,~oo,~. \ I Lot 20 / Lo! 17 I0' UTUTY EASEMENTS $ 89°56'30"W 153.78' ~~1(:: (ACCORDING 1'0 t.Y-~- '~ ~.~ SEPTIC Ct. EAN-OUTS PLOT PLAN WELL WELL & SEPTIC ASBUILT X SCALE I' · Oo' GRID 2440 Prolect No. ~-194 La~ ~, ASSA~I~i, Oe I.c. 115q0 Daryl Avenue, Anchorage, Alaska 99515 ,,~ ~. n v,,,~...~ ,,, (9071 522-6476 Phone ~_.~:~.~ Reglsfered Land Surveyors ~907)522-4625 Fax x,~.'~..O.~F...~i..'~.~'~, I hereby certify that l hove eurveyed the followlng described property, .~.~.,.~.'~..." Lo, 20..~o~k ~. co.m .E~H~S (,~at ,o. 7~-~70) ~/,,~..:" ~ '..~%. Anchorage Recording Dl~rlat, AJaeka. end that the Impmvemento eltu~tod .~CO?' E~.CITI-I ~ ~ "*"~., thereon om wlthln the properly Ilnes and do not encroach onto the pmperfy ,~..~.~:..,.~...~..."~...'..,~..~..~1....:?..~ adlaeent thereto, that no Improvemento on the properly lying adlacenf thereto ~ I/' ..L 4 ,'"/ encroach on the ~urveyed premleee and that there are no roadwaye, fran.mleeton ~ [/...~b~(~)~/~l fines or other vlelble laeemento on eald properly except ae Indleatod hereon. ~/~':.'~',,~.,.~'~';'I"'.:~<~:'~.'~; ~/L'O-- -'*,KENNETH G. It la the respenelblllty ef the owner fo detormlne the exldence of any '~'~,e,~: '" eaeemento, covenant8, or resfrlatlone which do not appear on the recorded subdlvleton plat, jepLhM3 GE BG • Municipality of Anchorage On -Site Water and Wastewater Program (907) 343-7904 `) Sk, 5 F T V Certificate of On -Site Systems Approval Parcel I. D.015-093-56 Expiration Date: 1. GENERAL INFORMATION: Complete legal description CONIFER HEIGHTS: BLOCK 1, LOT 20 Location (site address) 7620 LODGE POLE COURT *Chugiak, AK 99567 Current Property owner(s) STEVE O'DONNEL Day phone 907-244-3754 Mailing address Real Estate Agent RUTH BARNDT Day phone 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual 19 Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ M) Date of Payment 33 9/popzo Receipt Number 0 C15W-4z COSA# ase -06 /107 Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date: A c In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the system/s on the date/s of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or encroachments may exist that were not identified during the evaluation. The operational life of all wells and septic systems depend upon a variety of variables, including but not limited to, soil conditions, groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, anc� are outside the control of GEG. Satisfactory test results do not guarantee future performance of thq system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of the well or septic system. GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the current systems fail to perform adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG to perform the evaluation. Reliance upon the information provided in this report by any other person or party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. 6. DSD SIGNATURE C System #1 Approved for _1� bedrooms System #2 Approved for bedrooms Disapproved Conditional approval for bedrooms, 4 H*( ., ii ........... ...... of y A. Gornesls; C 953 Pro f essio�oa� #AECC884 9KUTY(0,4 with the followifftipOYA; ' ER AND M 1,4 Ali -.•��J1i T sERV4CEs�'- Ilii!!i1 By: Original Certificate Date: ^W^2� The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist Nitrate Advisory_ Septic System Advisory Arsenic Advisory Well Flow Advisory Other`. Age Legal Description: CONIFER HEIGHTS; BLOCK 1, LOT 20 Parcel ID: 015-093-56 If more than 1 septic system on lot: COSA Checklist # of Structure served by this system A. WELL DATA ❑ Well log is filed with Onsite (or attached) Well production at time of test 1.8+ gpm Date drilled 3//12000 Water storage tank volume N/A gallons Total depth 246 ft Well disinfected for coliform test? ❑ Yes ❑ No Cased to 246 ft / I- " U Coliform bacteria is Negative Measured depth to pipe invert from grade 5.1 ft (min) Water added 678 gal ❑ Sanitary seal is functioning correctly Nitrate `! mg/L ❑ Nitrate less than MRL (ND) ❑ Wires are properly protected Arsenic ug/L ®Arsenic less than MRL (ND) Casing height (above ground) 18+ in. Collected by GEG Date of flow test for COSA 3/12/20 Date of Sample 3/11/20 Static water level at beginning of test Final fluid depth 48.5 in Comments v (Required if vacant for greater than 30 days prior to 6r— G , ? tG—c lrc� �� �.-!")G � �l -� �-�-^ ('6r' � `rl'i.�ti--s��-j' -''l �" L "ii * t� •c.�.- L .I� Ga,- S .. �d �.i :� ,�C'`,� B. TANK DATA C. LIFT STATION Age of tank(s) 20 years ❑ Required maintenance comple Tank type/material SE""sTEE Age of lift station s Measured operating fluid level in septic tank 49.5 Lift station mated ❑ Standpipes/foundation cleanout per record drawing Commen ' Date of pumping 11/4/2019 r' D. ABSORPTION FIELD DATA Which system tested (date installed) 2129'2060 Adequacy test date 3/12/20 ,9ALL standpipes present per record drawing Results ❑✓ Pass For 4 bedrooms Total measured depth from grade 9.25 ft (max) Fluid depth prior to test 40 in Measured depth to pipe invert from grade 5.1 ft (min) Water added 678 gal ❑ N/A — pressurized field 50 New depth in ❑ Monitor tubes go to bottom of effective. If not, state 120 depth into effective 4.2 Elapsed time min P ❑ Code -required soil cover over field Final fluid depth 48.5 in ❑ System presoaked Absorption rate 600+ gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) NO date of test) Gallons introduced N/A gallons If yes, enter date N/A Comments/Deficiencies: *MT GOES DEEPER THAN THE TOTAL EFFECTIVE -TESTED NORTH TRENCH ONLY LIQUID WAS FILLED TO THE BOTTOM OF THE INVERT - IN SHORT, THE NORTH DRAINFIELD WAS FILLED TO 100% CAPACITY AT THE END OF THE TEST&#13;SOUTH TRENCH LIQUID LEVEL WAS 44 INCHES (MT EXTENDS 49 INCHES BELOW CLEANOUT ELEVATION) THROUGHOUTTHETEST -HERE WAS SOME DEBRIS IN THE EAST CLEANOUT ON THE NORTH TRENCH - WE RECOMMEND HAVING THE CLEANOUT "PUMPED" TC CLEAR OUT DEBRIS THE NEXT TIME THE TANK IS PUMPED SEPTIC SYSTEM PASSED MARGINALLY. ADVISORY NOTICE SHOULD BE ISSUED WITH THE COSA COSA Checklist yellow sheet n10 E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ❑ Yes if No Community Sewer Manhole/Cleanout > 100' Q✓ Yes if No ft M Yes if No ft Neighboring Tank > 100' [✓ Yes if No ft Private Sewer/Septic Line > 25' Yes if No ft Absorption Field on Lot > 100' ❑✓ Yes if No ft Holding Tank > 100' Yes if No ft Neighboring Absorption Fields > 100' if No ft Animal Containment > 50' 0✓ Yes if No ft M Yes if No ft ft If septic tank is under driveway comment below Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' MV Yes if No ft M Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑ Yes if No *51+ ft Surface Water > 100' Q Yes if No ft Property Line > 5' P/1 Yes if No ft Wells on Adjacent Lots: Wells on Adjacent Lots: Absorption Field > 5' 0 Yes if No ft Private Wells > 100' F.71 Yes if No ft Water Main > 10' Q Yes if No ft Community Wells > 200' r7l Yes if No ft Water Service Line > 10' Q Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' E✓ Yes if No ft If absorption field is under driveway comment below Property Line > 10' ❑ Yes ** if No ft Wells on Adjacent Lots: Water Main > 10' 0 Yes if No ft Private Wells > 100' F Yes if No ft Water Service Line > 10' P-1 Yes if No ft Community Wells > 200' Q✓ Yes if No ft Surface Water > 100' 0 Yes if No ft F. ENGINEER'S COMMENTS *CODE AT TIME OF INSTALLATION **DRAINFIELD IS OFF PROPERTY - SEE MOA RECORDS FOR EASEMENT G. ENGINEER'S CERTIFICATION l certify that / have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet ..?. !.� 3... Q .J ffi y A. Gorness.- QQ 9• ` . R(CE-7953 �zp� rP � F. aprofessioo°o #AECC884 DEVELOPMENT SERVICES DEPARTMENT On -Site water and wastewater Section www.muni.org/onsite l = , 907-343-7904 Fax: 343-7997 Nitrate Advisory Certificate of On -Site Systems Approval # OSC201107 Subdivision: Conifer Heights, Block: 1, Lot: 20 A water sample revealed a nitrate concentration of 9.89 milligrams per liter (mg/Q. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. x Mailing Address P O Box 196650 *nchorageyAlaska'59519'-'6650'*www muni org cJ From Northern Testing Laboratories, Inc. Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples. flVlaihng Address P O Box 196650 *Anchorage, Alaska 99519 6650 *www muni org E DEVELOPMENT SERVICES DEPARTMENT On -Site Water and Wastewater Section www.muni.org/onsite Septic Tank Advisory Certificate of On -Site Systems Approval #OSC201107 Subdivision: Conifer Heights BLK 1 Lot 20 907-343-7904 Fax: 343-7997 Starting at 20 years of age the MOA issues Advisory's for steel septic tanks. The septic tank for this property is 20 years old. Typical replacement costs range from $8,000 to $11,000. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. This is an example of what the metal of a 20 year old steel tank MAY look like. Municipality of Anchorage R r..._ Development Services Department Building Safety Division s A E r Y On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www. c i. anchorage. ak. us (907) 343-7904 Septic System Advisory Certificate of On -Site Systems Approval # OSC201107 During a recent adequacy test on the septic system for Block 1, Lot 20 of Conifer Heights subdivision, 40 inches of standing water was observed in the absorption field. This indicates that approximately 90% of the absorption area is inundated. Although this system passed the adequacy test, the remaining life expectancy may be limited. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval