HomeMy WebLinkAboutSUN VALLEY BLK 1 LT 2Sun Vail
Y
Block
Lot 2
#078-101-02
. Municipality of Anchorage Page I of ."--'~
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL'SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: '~'~/4~ O O I {~ (~ PI D Number: ~'7~' - I ~1 - ~ ~
.,m ~ ~~ WastewaterSystem: ~ New D Upgrade
Address:i~ ~~,~ ~,'~J< ABSORPTION FIELD
SEPARATION DISTANCES ~,p,~ n.o~a~ ~.~.~.~.
su,,~, NIo LIFT STATION
Remarks: BENCH MARK
ENGINEER'S ~EAL
Department of Health an~ Human Sewices approval ' ~' ' ' '
Reviewed and approved b ate: -I-o I '~ ,.... ·
25
$£~D 1' = $~ FT.
TOBBEN SPU£KLAND P.E.
203 W 15TH. AVENUE
ANCH. AK. 99501
PERMIT # SIV990XXX
~ IYell
SINOLE £A.VILY RESIDENCE
4 BED£O01~$
OD J2.~ ~
AE
AF 52
Rr 54
STANDARD $-~/IDE TRENCH
TOTAL LENOTH 45 ~
TO~L DEP~X ~.5 ~
EFFE~TIV~ ROCK 2.5 r~ r TRENCH
REPL4CENENT TRENCH
B £K
TOP £OUNDATION ASSUI~EO £LE¥, 100.00 f
II LOT2, BLOCK1 SUN
MILE 6.3 HIGHLAND ROAD
SUSAN MARCIE
PID # 078-101-08
I~LLEY
DATE: SEPT. 29, 2000
SHEET: 2/5 GRID: SW 859
SUNOI O22.flWG
/~ ,t-INCH INSULATION
8~ AI~CO~PRESSOR
8~.~
TOTAL ROCK DEPTH JO INCHES
EFFECnVE ROCK DEPTH 24 INCHES
TOTAL COVER ~ FT.
I. PRIMARY TREAT~EN~ SEPTIC ~ANK
2. AERATION ~ANK
~. C~RIFICATION TANK
4. DISCHARGE TANK
~. SOIL ABSORPTION
~OBBEN 5PURK~ND P.E. LO~ 2, BLOCK L SUN VALLEY SEPTIC SYSTE~ DESIGN
205 V/16th Ave
Anchoroqe Ak ~950~ WASTEWATER SYSTE~ SCHEMATIC DA~E: SEPT.29, 2000
279-39~ SUSAN ~ARCIE SHEE~' ~/~ GRID: SW 8~
PER~IT ~ SW000~69 PID NO 078-~0~-02 SUNOIO25. D~/G
by
SULLIVAN WATER WELLS
P.O. BOX 670272, CHUGIAK, ALASKA gg$'~7 · TELEPHONE g88-27&g
OWNER 'OF LAND
^DDRESS /
LEGAL DESCRIPTION
PERMIT NUMBEROGG I ~ ~ Date of Issue ~;~ -
TAX INDENTIFICATION NUMBER ,O7~' _~)
Is well located at approved permit location? ~ [~ No
Method of Drilling: (~J'~r""~r rotary [~ cable tool
~'~Z 4 /~,Jr~ i/~lq~, C ~' BOREHOI. EDATA
DEPTH
Casing Type .~'Tc'~4- Wall Thickness , e~.~'~. Inches / e'7
°' feet
Diameter Inches, depth
.sing Stickup Above Ground: c~,
Static V~ater Level (from ground level):
Pumping level: feet after hrs. pumping
Recover Rate: :~ npm
Method of Testing: ~j/~
feet
feet
gpm
Well Intake Opening Type: [~'O~pen End D Open Hole
D Screened; Start feet Stopped feet
I'1 Perforations Start fee, tx Stopped feet
"rCEIVED
Depth: from 0 feet, to feet
Pump Intake Depth: feet
Pump Size .hp Brand Name
Well Disinfected Upon Completion? ~ [~1 N,,o#
Method of Disinfe~on: C~'/-/4'-',R~.-.I.I~ ,.~J//~',~ '
,Comments:
Driller's Name
o,-
'~" OOrvlce8
ATTENTION: It Is the responsibility of the property owner to 8ubmit a copy of the well log to the proper authartty. Municipality
of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. MatSu Borough:
Department of Environmental Conservation.
F*RO~ : C.C~Cl., ELECTRIC FF~< 1,40. : :34~,41~2 $ep. ~0 ~-"(~31 l~:~4Pr4 PI
CARCEL ELECTRIC, INC.
10,Il0 l~lu~ Or. Anchon~, AK
Ph~ ~07.346..40~0/F~:
July9,2001
$.zannc IVl~cie
1780 Driftwood Ch-,
Palmer, AK 99645
To whom it may concern:
C. arecl Electric ~ wired the Bio-Cycle locs~ed at Lot 2, Block 1, S~u Ve. lley
Mile 6.5 Highland rd. i~.Eagle River Akska.
This Bio-Cycle ~ wired per tho 1999 National Electrical Code. If you trove any
questbns, ple~se give me a call.
Steve Cloud
Oeneral Manager
MUNICIPALITY OF ANCHORA GE
Deparlment of Health and Human Services
On-Site Services Program
825 L Street, Room 502
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT
Renewal
Date Issued: Jun 15, 2000
Expiration Date: Jun 15, 2001
Permit Number: SW000169
Legal Description: SUN VALLEY BLK I LT 2
Design Engineer: 0007 Tobben Spurkland, PE
Owner Name: Susan Marcie
Owner Address: 1780 Driftwood Circle
Palmer, AK 99645-
Parcel ID: 078-101-O2
Total Bedrooms: 4
Site Address:
Lot Size: 468135 SQ. FT.
Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well [] Wate,r Storage
construction must be in accordance with:
1. The attached approved design.
2. ,NI requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours pdor to each inspection. Provide notification by calling
(907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
MUNICIPALITY' OF ANCHORAGE
Department of Health and Human Services
On-Site Services Program
825 L Street, Room 502
P.O. Box 196650, Anchorage, AK 99519-6650
(gO7) 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT
Initial
Date Issued: May 13, 1999
Expiration Date: May 12, 2000
Permit Number: SW990094
Legal Description: Sun Valley blk I Lt 2
Design Engineer. 0007 Tobben Spurkland, PE
Owner Name: Susan Marcie
OwnerAddress: 1780 Driftwood Circle
. Palmer, AK 99645-
Parcel ID: 078-101-02
Site Address: unknown
Lot Size: 468135 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] P[ivate Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. Ail requirements specified In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either. A. Open and closed on the same day,
B. Covered, sealed, and heated to prevent freezing,
5. The following special provisions.
biocycle - This permit is for a Biocycle system
A DHHS maintenance agreement is to be part of the As-built package.
The length of the trench is to be extended to 60'.
Date:
Date:
203 W 15th. Avenue, Suite 203
ANCItORAGE, ALASKA 9950 I
(907) 279-3916
Fax (907)-276-6013
SEPTIC SYSTEM DESIGN
SUN VALLEY S/D
LOT 2 BLOCK 1
SUSAN MARCIE
Municipality of Anchorage
Department of Health and Social Services
820 1 Street
Anchorage, Alaska 99501
June 13, 2000
We are resubmitting an application for the installation ora well and septic system for this lot.
The proposed building location has been moved, necessitating a new soil test and design. The
soil log of a testhole excavated on May 31, 2000 is enclosed.
The septic system design is based on the following: The ground slope is more than 30%, but
the soil is uniform and horizontal stratifications are not evident. Day lighting ofeffluent, or
slope instability will not result from this installation. The Owners desire to limit the ground
disturbance, a BioCycle unit is therefore preferred.
No Ground Water or Impervious Layer to 13 ft.
Use Standard 5 Wide Trench
Soil Rating. 2 min per inch Use 2.4 gal per square foot per day
No. of Bedrooms 4
Required Area per Bedroom: 150/2.4 =62.5sq.ft..
Total area required: 62.5 x 4 = 250 square feet
Use 12 inches of rock: Reduction factor .87
Total Trench Length 250 * .87/5 = 43.5 ft.
SYSTEM CONFIGURATION
BIOCYCLE
STANDARD 5-WIDE TRENCH
TOTAL LENGTH 45 FT
TOTAL WIDTH 5 FT
TOTAL DEPTH 4 FT
ROCK DEPTH 1 FT
COVER 3 FT
The installation of this well and septic system will not prevent wells and septic systems from
being installed on the adjacent lots. There are no developed or natural surface / sub surface
drainage courses on this or the adjacent lots.
The proposed septic system will not change the general slope ofthe area. Ponding and/or
concentration of surface runoff will not result from this installation.
1108B£N SPURKLAND P.E.
205 W ISTH. AVENUE
ANCN. Al(. 99501
(90Z~
~o~ \~ 2oD zoo 4oo
', ~ ",~;CALE: I"= 200 FI
LOl' 2, BLOCK I SUN
MILE 6.$ HIGHLAND ROAD
SUSAN MARClE
PID # YYY
VALLEY
VACANT
LOT I
LOT 2
LOT 3
VACANT
500
REVISED; JUNE i12, 2000
SYSTEm AND HO~)SE
RELOGATED
-- -NEW T~
SEPDC SYSTEY DES/ON
DATE: APRIL 27, 1999
SHEET: I/3 GRID: SW 8S9
SUNOIO£1. DWG
SCALE: ]' = 50 FT.
[TOBB£N SPURKLAND P.E.
205 W 15TN. AVENUE
ANCN. AN, 99501
PERMZT # SV29OXXX
SIMGL£ FAtdlLY RESIDENCE
4 BEORO0~S
S~MO4£flS-~'O£ TRENCN
IOTAL S£NG~N 45 fr
~O~L flEPrM 4 Fl'
££FEC~VEROGK I Irt
REPLACE~IEMt TRENCH
\
\
REVISED SI[EPLAN JUN£
NEW DES/GM
I]LOI'2, BLOCK1 SUN VALLE)'
Iffltf 6.3 HIGHLAND ROAD
SUSAN IffARCIE
PID # YYY
SEP[IC SYSTEIff DESIGN
DATE: APRIL 27, 1999
SHEET: 2/$ GRID: SW 859
SUNOlO22.BI¢'G
4-INCH INSULATION
_!
STANDARD 5-WIDE DRAIN FIELD
,-,/, ,vc .',r, ,Ir
TOTAL LENGTH 45 FT
TOTAL DEPTH 4 FT
TOTAL ROCK DEPTH I5 INCHES
EFFECTIVE ROCK DEPTH 12 INCHES
TOTAL COVER $ FT.
0 0 0 ~. ~
) 0 0 0 0 ',.,
.0--0--0--0--0 0 ~,-- .~ Sllr B.4,qRIER
) 0 0 0 0 0 0 0 0 0 0 0 ,~
0 0 0 0 0 0 0 0 0 0 0 0 0 ~
INSULATION
NO SCALE
,,1
TESTHOLE
16 FT. DEEP
LEGEND:
I. PRIIWARY TREATMENT, SEPTIC IANK
AERATION TANK
3. CLARIFICATION TANK
4. DISCHARGE TANK
5. SOIL ABSORPTION
REVISED JUNE 12, 2000
12 INCHES OF SEWER ROCK
IIOBBEN SPURKLAND P.E.
205 Wl5th Ave
Anchoroqe Ak 99501
279-J9 7F;
PERMIT ,(/ SW990XXX
LOT 2, BLOCK 1, SUN gtLL£Y
WASTEWATER SYSTEM SCHEMATIC
SUSAN MARCIE
PID NO YYY
SEPTIC SYSTEIW DESIGN [
DATE: JULY Jl, 1997 m
SHEEr: j/$ GRID: SW 8.~
I
SUNOIO2J. DWO
PERFORMED FOR:
RuniC,; aIlly ol Anchorage
DEPARTMENT O;: ~EALTH & HUMAN SERVICES
825 "L'* Street. A.(:horage, Alaska 99502-0650
SOILS LOG - PERCOLATION TEST
e~.": .' (ENGINEER'S SEAL)
LEGAl. DESCRIPTION:,
2
3
4
5
6
7-
10
11
12
13
14
16-
17-
1~-
20-
DISCLAIMFR · Arn.ndwnter
Past and future presence
trom these o~,~rvatlon$.
PERFORMED BY;
Township, Range, Section:
SLOPE
WASGROUNDWATER
E"COUNTER;O? 'ID
IF YES, AT WHAT
DEPTH?
Mo~ilorin97 /~ ~ O(le:
SITE PLAN
PERCOLATION RATE ~ (m,nule~,nch) PERC HOLE DIAMETER .
TLSTRUNBETWEEN ~ FTA~O~FT
cnndtttnns indicated atp for the dates
~nd/or depth of groundwater can not be
shown only.
predicted
i '~ -~ CERTIFY THAT THIS TEST WAS PERFORMED IN
· ACCORDANCEWITHALLSTATEANDMUNICIPALGt~;.ELINESlNEFFECTONTHiSOA~F. DATE: ~ / ~, ~.4~,'4~A
72-0~ (Rev. 4/851
PROPERTY OWNER MAINTENANCE AGREEMENT
ON-SITE WASTEWATER DISPOSAL SYSTEM
This agreement, dated ~.~u~, ,~-'~"'/ ,200_0, is made between the Municipality of
Anchorage Department of tleal~ and Human Services (DHHS) and the property owner(s) of
I
This agreement is made for the purpose of maintaining an on-site wastewater disposal system
on the subject property.
The property owner(s) agree to the following:
The property owner(s) will have an annual inspection of the system performed by a registered
professional engineer. This inspection shall verify that all effluent and air pumps, timers, and
alarms are functioning as designed. Any deficiencies shall be corrected and the engineer's
statement that the system is functioning as designed shall be filed annually with the DHHS.
.// Pr~p'.,~rty Owner Name
Property Owner Name
.ludicial District .~'Q SS.
On this a~q_. day o f ~O,A4 inthe
year e~)_, before me, thdundersigned notary
p~bli¢, person.ally appeared:
,.gbva~ne ~l~CtrCc! Imown to me to be
tbe,l]erson(s) whose name05 is/are subscribed to the
within instrument and acknowledged that he/she/they
executed the same for the purposes therein
contained.
In witness whereof, I hereunto set my hand and
My commi.ssion expires: __