HomeMy WebLinkAboutSUN VALLEY BLK 1 LT 2Sun Vail Y Block Lot 2 #078-101-02 . Municipality of Anchorage Page I of ."--'~ DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL'SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: '~'~/4~ O O I {~ (~ PI D Number: ~'7~' - I ~1 - ~ ~ .,m ~ ~~ WastewaterSystem: ~ New D Upgrade Address:i~ ~~,~ ~,'~J< ABSORPTION FIELD SEPARATION DISTANCES ~,p,~ n.o~a~ ~.~.~.~. su,,~, NIo LIFT STATION Remarks: BENCH MARK ENGINEER'S ~EAL Department of Health an~ Human Sewices approval ' ~' ' ' ' Reviewed and approved b ate: -I-o I '~ ,.... · 25 $£~D 1' = $~ FT. TOBBEN SPU£KLAND P.E. 203 W 15TH. AVENUE ANCH. AK. 99501 PERMIT # SIV990XXX ~ IYell SINOLE £A.VILY RESIDENCE 4 BED£O01~$ OD J2.~ ~ AE AF 52 Rr 54 STANDARD $-~/IDE TRENCH TOTAL LENOTH 45 ~ TO~L DEP~X ~.5 ~ EFFE~TIV~ ROCK 2.5 r~ r TRENCH REPL4CENENT TRENCH B £K TOP £OUNDATION ASSUI~EO £LE¥, 100.00 f II LOT2, BLOCK1 SUN MILE 6.3 HIGHLAND ROAD SUSAN MARCIE PID # 078-101-08 I~LLEY DATE: SEPT. 29, 2000 SHEET: 2/5 GRID: SW 859 SUNOI O22.flWG /~ ,t-INCH INSULATION 8~ AI~CO~PRESSOR 8~.~ TOTAL ROCK DEPTH JO INCHES EFFECnVE ROCK DEPTH 24 INCHES TOTAL COVER ~ FT. I. PRIMARY TREAT~EN~ SEPTIC ~ANK 2. AERATION ~ANK ~. C~RIFICATION TANK 4. DISCHARGE TANK ~. SOIL ABSORPTION ~OBBEN 5PURK~ND P.E. LO~ 2, BLOCK L SUN VALLEY SEPTIC SYSTE~ DESIGN 205 V/16th Ave Anchoroqe Ak ~950~ WASTEWATER SYSTE~ SCHEMATIC DA~E: SEPT.29, 2000 279-39~ SUSAN ~ARCIE SHEE~' ~/~ GRID: SW 8~ PER~IT ~ SW000~69 PID NO 078-~0~-02 SUNOIO25. D~/G by SULLIVAN WATER WELLS P.O. BOX 670272, CHUGIAK, ALASKA gg$'~7 · TELEPHONE g88-27&g OWNER 'OF LAND ^DDRESS / LEGAL DESCRIPTION PERMIT NUMBEROGG I ~ ~ Date of Issue ~;~ - TAX INDENTIFICATION NUMBER ,O7~' _~) Is well located at approved permit location? ~ [~ No Method of Drilling: (~J'~r""~r rotary [~ cable tool ~'~Z 4 /~,Jr~ i/~lq~, C ~' BOREHOI. EDATA DEPTH Casing Type .~'Tc'~4- Wall Thickness , e~.~'~. Inches / e'7 °' feet Diameter Inches, depth .sing Stickup Above Ground: c~, Static V~ater Level (from ground level): Pumping level: feet after hrs. pumping Recover Rate: :~ npm Method of Testing: ~j/~ feet feet gpm Well Intake Opening Type: [~'O~pen End D Open Hole D Screened; Start feet Stopped feet I'1 Perforations Start fee, tx Stopped feet "rCEIVED Depth: from 0 feet, to feet Pump Intake Depth: feet Pump Size .hp Brand Name Well Disinfected Upon Completion? ~ [~1 N,,o# Method of Disinfe~on: C~'/-/4'-',R~.-.I.I~ ,.~J//~',~ ' ,Comments: Driller's Name o,- '~" OOrvlce8 ATTENTION: It Is the responsibility of the property owner to 8ubmit a copy of the well log to the proper authartty. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. MatSu Borough: Department of Environmental Conservation. F*RO~ : C.C~Cl., ELECTRIC FF~< 1,40. : :34~,41~2 $ep. ~0 ~-"(~31 l~:~4Pr4 PI CARCEL ELECTRIC, INC. 10,Il0 l~lu~ Or. Anchon~, AK Ph~ ~07.346..40~0/F~: July9,2001 $.zannc IVl~cie 1780 Driftwood Ch-, Palmer, AK 99645 To whom it may concern: C. arecl Electric ~ wired the Bio-Cycle locs~ed at Lot 2, Block 1, S~u Ve. lley Mile 6.5 Highland rd. i~.Eagle River Akska. This Bio-Cycle ~ wired per tho 1999 National Electrical Code. If you trove any questbns, ple~se give me a call. Steve Cloud Oeneral Manager MUNICIPALITY OF ANCHORA GE Deparlment of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Renewal Date Issued: Jun 15, 2000 Expiration Date: Jun 15, 2001 Permit Number: SW000169 Legal Description: SUN VALLEY BLK I LT 2 Design Engineer: 0007 Tobben Spurkland, PE Owner Name: Susan Marcie Owner Address: 1780 Driftwood Circle Palmer, AK 99645- Parcel ID: 078-101-O2 Total Bedrooms: 4 Site Address: Lot Size: 468135 SQ. FT. Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Wate,r Storage construction must be in accordance with: 1. The attached approved design. 2. ,NI requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours pdor to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. MUNICIPALITY' OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (gO7) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: May 13, 1999 Expiration Date: May 12, 2000 Permit Number: SW990094 Legal Description: Sun Valley blk I Lt 2 Design Engineer. 0007 Tobben Spurkland, PE Owner Name: Susan Marcie OwnerAddress: 1780 Driftwood Circle . Palmer, AK 99645- Parcel ID: 078-101-02 Site Address: unknown Lot Size: 468135 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] P[ivate Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. Ail requirements specified In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either. A. Open and closed on the same day, B. Covered, sealed, and heated to prevent freezing, 5. The following special provisions. biocycle - This permit is for a Biocycle system A DHHS maintenance agreement is to be part of the As-built package. The length of the trench is to be extended to 60'. Date: Date: 203 W 15th. Avenue, Suite 203 ANCItORAGE, ALASKA 9950 I (907) 279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN SUN VALLEY S/D LOT 2 BLOCK 1 SUSAN MARCIE Municipality of Anchorage Department of Health and Social Services 820 1 Street Anchorage, Alaska 99501 June 13, 2000 We are resubmitting an application for the installation ora well and septic system for this lot. The proposed building location has been moved, necessitating a new soil test and design. The soil log of a testhole excavated on May 31, 2000 is enclosed. The septic system design is based on the following: The ground slope is more than 30%, but the soil is uniform and horizontal stratifications are not evident. Day lighting ofeffluent, or slope instability will not result from this installation. The Owners desire to limit the ground disturbance, a BioCycle unit is therefore preferred. No Ground Water or Impervious Layer to 13 ft. Use Standard 5 Wide Trench Soil Rating. 2 min per inch Use 2.4 gal per square foot per day No. of Bedrooms 4 Required Area per Bedroom: 150/2.4 =62.5sq.ft.. Total area required: 62.5 x 4 = 250 square feet Use 12 inches of rock: Reduction factor .87 Total Trench Length 250 * .87/5 = 43.5 ft. SYSTEM CONFIGURATION BIOCYCLE STANDARD 5-WIDE TRENCH TOTAL LENGTH 45 FT TOTAL WIDTH 5 FT TOTAL DEPTH 4 FT ROCK DEPTH 1 FT COVER 3 FT The installation of this well and septic system will not prevent wells and septic systems from being installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope ofthe area. Ponding and/or concentration of surface runoff will not result from this installation. 1108B£N SPURKLAND P.E. 205 W ISTH. AVENUE ANCN. Al(. 99501 (90Z~ ~o~ \~ 2oD zoo 4oo ', ~ ",~;CALE: I"= 200 FI LOl' 2, BLOCK I SUN MILE 6.$ HIGHLAND ROAD SUSAN MARClE PID # YYY VALLEY VACANT LOT I LOT 2 LOT 3 VACANT 500 REVISED; JUNE i12, 2000 SYSTEm AND HO~)SE RELOGATED -- -NEW T~ SEPDC SYSTEY DES/ON DATE: APRIL 27, 1999 SHEET: I/3 GRID: SW 8S9 SUNOIO£1. DWG SCALE: ]' = 50 FT. [TOBB£N SPURKLAND P.E. 205 W 15TN. AVENUE ANCN. AN, 99501 PERMZT # SV29OXXX SIMGL£ FAtdlLY RESIDENCE 4 BEORO0~S S~MO4£flS-~'O£ TRENCN IOTAL S£NG~N 45 fr ~O~L flEPrM 4 Fl' ££FEC~VEROGK I Irt REPLACE~IEMt TRENCH \ \ REVISED SI[EPLAN JUN£ NEW DES/GM I]LOI'2, BLOCK1 SUN VALLE)' Iffltf 6.3 HIGHLAND ROAD SUSAN IffARCIE PID # YYY SEP[IC SYSTEIff DESIGN DATE: APRIL 27, 1999 SHEET: 2/$ GRID: SW 859 SUNOlO22.BI¢'G 4-INCH INSULATION _! STANDARD 5-WIDE DRAIN FIELD ,-,/, ,vc .',r, ,Ir TOTAL LENGTH 45 FT TOTAL DEPTH 4 FT TOTAL ROCK DEPTH I5 INCHES EFFECTIVE ROCK DEPTH 12 INCHES TOTAL COVER $ FT. 0 0 0 ~. ~ ) 0 0 0 0 ',., .0--0--0--0--0 0 ~,-- .~ Sllr B.4,qRIER ) 0 0 0 0 0 0 0 0 0 0 0 ,~ 0 0 0 0 0 0 0 0 0 0 0 0 0 ~ INSULATION NO SCALE ,,1 TESTHOLE 16 FT. DEEP LEGEND: I. PRIIWARY TREATMENT, SEPTIC IANK AERATION TANK 3. CLARIFICATION TANK 4. DISCHARGE TANK 5. SOIL ABSORPTION REVISED JUNE 12, 2000 12 INCHES OF SEWER ROCK IIOBBEN SPURKLAND P.E. 205 Wl5th Ave Anchoroqe Ak 99501 279-J9 7F; PERMIT ,(/ SW990XXX LOT 2, BLOCK 1, SUN gtLL£Y WASTEWATER SYSTEM SCHEMATIC SUSAN MARCIE PID NO YYY SEPTIC SYSTEIW DESIGN [ DATE: JULY Jl, 1997 m SHEEr: j/$ GRID: SW 8.~ I SUNOIO2J. DWO PERFORMED FOR: RuniC,; aIlly ol Anchorage DEPARTMENT O;: ~EALTH & HUMAN SERVICES 825 "L'* Street. A.(:horage, Alaska 99502-0650 SOILS LOG - PERCOLATION TEST e~.": .' (ENGINEER'S SEAL) LEGAl. DESCRIPTION:, 2 3 4 5 6 7- 10 11 12 13 14 16- 17- 1~- 20- DISCLAIMFR · Arn.ndwnter Past and future presence trom these o~,~rvatlon$. PERFORMED BY; Township, Range, Section: SLOPE WASGROUNDWATER E"COUNTER;O? 'ID IF YES, AT WHAT DEPTH? Mo~ilorin97 /~ ~ O(le: SITE PLAN PERCOLATION RATE ~ (m,nule~,nch) PERC HOLE DIAMETER . TLSTRUNBETWEEN ~ FTA~O~FT cnndtttnns indicated atp for the dates ~nd/or depth of groundwater can not be shown only. predicted i '~ -~ CERTIFY THAT THIS TEST WAS PERFORMED IN · ACCORDANCEWITHALLSTATEANDMUNICIPALGt~;.ELINESlNEFFECTONTHiSOA~F. DATE: ~ / ~, ~.4~,'4~A 72-0~ (Rev. 4/851 PROPERTY OWNER MAINTENANCE AGREEMENT ON-SITE WASTEWATER DISPOSAL SYSTEM This agreement, dated ~.~u~, ,~-'~"'/ ,200_0, is made between the Municipality of Anchorage Department of tleal~ and Human Services (DHHS) and the property owner(s) of I This agreement is made for the purpose of maintaining an on-site wastewater disposal system on the subject property. The property owner(s) agree to the following: The property owner(s) will have an annual inspection of the system performed by a registered professional engineer. This inspection shall verify that all effluent and air pumps, timers, and alarms are functioning as designed. Any deficiencies shall be corrected and the engineer's statement that the system is functioning as designed shall be filed annually with the DHHS. .// Pr~p'.,~rty Owner Name Property Owner Name .ludicial District .~'Q SS. On this a~q_. day o f ~O,A4 inthe year e~)_, before me, thdundersigned notary p~bli¢, person.ally appeared: ,.gbva~ne ~l~CtrCc! Imown to me to be tbe,l]erson(s) whose name05 is/are subscribed to the within instrument and acknowledged that he/she/they executed the same for the purposes therein contained. In witness whereof, I hereunto set my hand and My commi.ssion expires: __