Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutGLENN VIEW ESTATES WEST PH 1 BLK 2 LT 10Glen View
West Phase 1
Block 2
Lot 10
#051-793-14
Municipality of Anchorage
Development Services Department
Building Safety Division - �•.i1
eOn-Site Water and Wastewater Program, 4700 S. Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650 Page
www.d.anchorage.ak.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number. SW010005 PID Number. 051.793-14
,
of
Nemec
Arctic Devco. Inc.
Wastewater System:
0New
■ Upgrade
Address:
PO Box 3489. Palmer. AK 99645
ABSORPTION FIELD
Phone: Number dBedrooms:
4
Trench DDeepTr0SMaowTrench DSed 13 Mound Doow:
LEGAL DESCRIPTION
5ai Ram
0.6 GPDIFI9
Total Depth from agncl Wad.:
5.48.6.00 Ft.
&act Lot aumwlon:
2 10 Pitt-, / Glenn View West
Depen to pipe bottom from anginal pads:
2.45.3.09 Ft.
Gravel
depth beneath ppe:
3.03.2.91 FL
Townley: auq.: S.dcn:
Fm added Woe original grade:
1.17 Ft.
Grovel Length:
117 Ft.
Well: 0 New5
0 Upgrade
Gravel `"m:
Ft.
Number a Met Distance
bee en in.t
2 10 Ft
Ctaaubobon (Prmu, A. B. C):
Public Water
Total Depth:
Ft.
Goad to:
FL
Taal absorption avec:
1008 Fr
Pipe IA+a W:
SCH40 & F810
Dow:
Dat. Dried:
Sum Waw Levet:
FL
kn*sI.:
Turner Const.
Data Installed:
01/10/01
Yield:
GPM
Pump Sod at
FL
Casing Height Amo. Grand:
FL
TANK
SEPARATION DISTANCES
® Septic 0 Holding • S.T.E.P. 0 Other:
T..
From
Septic
Tank
Absorption
Field
Lin
Station
Holding
Tank
Public/Privatec•pa�lr�
Sewer Line
M'ulaclua:
Anchorage Tank
1250 Gal.
Well
200'+
200'+
NA
NA
25'+
SM el
Number
2D"�"" ""
&tramwaw
100'+
100'+
NA
NA
LIFT STATION
Lot Lino
5'+
10'+
NA
NA
srt.:
Gat
Manufacturer
Foundation
5'+
10'+
NA
NA
lev
'Pump of el at
in.
-Pump iron larat
F.
High waw Mum at
H.
Detain Drain
NA
*50'+
NA
NA
pump Maks a Madel
E•,.Mtal Impecbone
p-rwm.d fry.
Dueto
Due to elevation at foundation, the depth of gravel was reduced 1'
BENCH MARK
and trench lengthened 17'.
Locauon and Descnpu n:
Top of door sill.
Assumed lleraLan.
100 Ft.
Engineer's Stamp
P�EOF q................
e* •'49.1H «e..1
Inspections performed by: KND Engineering Dates: 1't 01/11/2001
Zed 1112/2001
-e«tie •Ya••.••••
a-s Kenne.n .. uuffu ��
Je CE 7116 ! fir"/
6'' '•• . ' G` 0
tl1FokROF ••810 so
Development Se ices Department Approval l
Reviewed and approved by: Date: 8'2�'O t
(prove WOO)
AS—BUILT
GLE
VACANT
ot 11
B—D=23.8'
C—D=27.6'
B—E=16.1'
C—E=32.9'
A—F=57.9'
B—F=30.8'
A—G=63.0'
B—G=42.4'
A—H=44.3'
B—H=74.8'
SYSTEM DETAILS/SIT
NN VIEW WEST S/D, LOT 10,
CD+ Ci 1!
MT
00,
VE FIELD
MARY r
KND9-2/10
1250 GAL
SEPTIC TANK
LIT
B
CO 4 BORN MOUSE
E
N
}CO
MT
E
BL
ABLE A
DRIVEWAY
1' a
PLAN Perr'li
OCK 2 PID#0
rC
10
rnC
50'
t S
51—
W010005
793-14
ami
FINAL GRADE
rr9u T T �, no:cn-Ilti��
FILM ru,M\ _ P SLLAIK.
I�111JIP
SEVER ROCK
TRENCH 1
SCALE: NTS
4. -Pc QY C) °F..` 9S
C*49
FT
CE -7116 (©A&
V iStreSS1OS '
SEVER ROCK 1 +„
91.18 TRENCH 2 91.19
blty1gIGIGICINIti:r-�:I--III--nI--IIIyI1�IC IH
IOD'
(--85.197
PREPARED FOR:
TURNER CONSTRUCTION
P.O. BOX 3489
PALMER, AK. 99645
242-4555
SCALE: NTS
FIELD BOOKS
°01M0"" LANG
Signe: LANG
Is" 'ft* VBG
°t°Eo KMD
411.at LANG
°At 6/13/01
LEND ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
DNC, FIE:
ca - NW1459
"CAO ^'E' 01001.0WC
a N" 01001
(907)898-8111/FAX (907)698-8111
)K ID ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
SOILS PERCOLATION TEST
Performed for. Arctic Devco
Project
Depth
(Feet)
1-
2-
3-
4-
i* r91;:tirts
49� ti
e•
1.
f4
�9tO� R7SS_Nf e
i""Kann.h M. Uuf
Date Performed: 01/11/01
Lot 10, Block 2, Glenn View West TEST HOLE # 01-1
SEE Til 99-2/10
5- GVW, B2, L10
Material consistent
6-
Perc performed at bottom
7- of trench
8-
9-
10-
11-
12-
13-
14-
15-
16-
17-
18-
19-
20 -
SEE ATTACHED SITE PLAN
FOR HOLE LOCATION
Was Ground water encountered? No What depth? NA
Depth to water after monitoring? NA Date? NA
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
1
01/11/01
11:30
-
6"
-
2
12:00
30 min
412/16"
14/16"
3
•
12:01
-
6"
-
4
12:31
30 min
413/16"
13/16"
5
*
12:32
-
6"
-
6
1:02
30 min
4 13/16"
13/16"
*
Water
Added
Percolation Rate 25.26 (min/in Perc Hole Diameter 6"
Test Run Between 6 fee and _7_ feet
I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in
effect on this date.
• Aug. 6. 200P: 2:09PWnco,9075622175,
•
No.1802 P. 2/3
7419 ac4 9344 - 2/ 3
Buil Run® Valve
Specification Sheet
SIZE: 4" Valve Ports
MATERIAL: PVC
WEIGHT: 2Y2 Pounds
POSITIONER: Manual with
Internal Stop
Valve Body
Direction Control Handle •
® Valve "IN" Port
® Valve "OUT" Port
® Riser Tube Connection
® Positioning Shape
® Indicator Number
astritlyi
O 'R/earfrti ayw
or 0
1200 , 1
OPERATION OF VALVE
The Direction Control Handle Is turned using the valve
standardkey (a
vided so the
PO itJ ningShape on the Direct key)
Control Handle Is
perfectly In Ilne with the corresponding Positioning
Shape labeled as No 1 or No. 2 on the valve body. The
. indicator number shows which side of the field Is In
' ,Bae:
7.50"
6.50"
6.00"
• The Internally tapered valve body and plug provide .'
compression Beating for operation. This design may
cause minimal resistance to the turning operation
which Is perfectly normal.
PATENT N0.4,217,933
Aug. 6. 2001, 2:28PMncor9075622175,
INSTALLATION INSTRUCTIONS
DIRECT BURIAL
The valve is designed to be buried directly in the pipe
trench requiring no concrete or hold down strap
Installation. The valve must be installed with the septic
tank effluent line connected to the valve port marked
"IN'. The valve ports marked "OUT" are connected to
each half of the drafnfield.
ADAPTABLE TO VARIOUS PIPES
Each valve port plus the riser tube connection are 4"
schedule 40 female connections. Use ample PVC,
ABS, or Multi-purpose glue to form a water -tight joint.
Any of the following Can be used to connect the Valve:
'1. Schedule 40 PVC or ABS pipe.
2. Adaptor Bushing (DWV hub to sewer a drain
spigot)
3. ASTM D2729 (Schedule 30) 4. Belled of ASTM D2729 (Scedule coupling0
pipe
OPERATION BY WATER METER KEY
• A riser pap adapter, a water -tight access cap and valve
key are provided. The valve should be burled at such a
depth as to allow easy access and operation from the
*ground surface with the standard water key provided.
•
PUMP SYSTEMS
Effluent pumps can be used to dose the drafnfield. The
top of the valve is o -ring sealed and pressure tight
under normal effluent pump operating conditions.
Maximum pressure 25 psi.
The Internal plug is tapered to match the valve body
seating vibe. This seating mechanism will prevent by-
pass under minimum head pressure conditions. To
prevent by-pass • under low pressure conditions,
specify the Bull Run Valve gasket.
LABEL AND INSTALLATION INSTRUCTIONS.
A label is provided with each valve sold. The label is
designed to be placed In a service area. possiblynear a
fuse box or circuit breakers. The label should serve a5
a helpful reminder to turn the valve, thus prolonging
the life of the septic system. Installation Instruction
and Instructions for filling out and placing the label we
provided with each valve sold.
No.7802 P. 3/3
;410 444 £344 • 3, 3
SAMPLE VALVE SPECIFICATION
A noncorrosive alternating valve shall be provided
with 4" schedule 40 female connections. The valve
plug shall be non -removable, watertight, and
externally operated. The valve shall be provided with
an Internal atop mechanism for positioning the plug,
and the plug shall be non -Jamming when turning from
stop to stop. There shall be no metal parts In contact
with the wastewater.
The Inlet and outlet ports shall be dearly labeled for
easy installation and the postion of the valve shall be
clearly indicated on top of the valve. At no time shall
the operator have contact (physical or visual) with the
wastewater. The valve shall be Installed In such a
manner as to be easily accessable from the ground
surface and operated with a standard water key
provided.
Simple Instructions for use and maintenance, printed
on durable material. shall be supplied along with each
device. The valve shall be a Bull Runt Valve.
•
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On -Site Services Program
825 L Street, Room 502
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-4744
1:`.,%s Asar
//'ooq.M,
/-//-0 /a 3:o0p,n
2 1vsT
I _ I2-0/ 2: oC,c,M.
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Date Issued: Jan 09, 2001
Expiration Date: Jan 09, 2002
Permit Number: SW010005 Parcel ID: 051-793-14
:Legal Description: Lot 10 Block 2 Glenn View Estates West Phase 1
Design Engineer: 0070 KND Engineering Site Address: Voyles Avenue
Owner Name: Tumer Construction Lot Size: 40000 SQ. FT.
Owner Address: PO Box 3487 Total Bedrooms: 4
Anchorage . AK 99645 -
Permit Bedrooms: 4
This permit is for the construction of:
Q✓ Disposal Field Q Septic Tank fl Holding Tank fl Privy 0 Private Well 0I Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-4744 (24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
arc Kt -4 /A,L 44_ -nu 1-flintis noel j 70 3 c '
t�`jn, sca.7i;c /c
t3aca-vss- .'4 *L -•y. '/L,.. {vb.) ti;„./Ltky t
net
4. II/� / /AMA.
/OK
/I r !e /✓.L,l
•
//Glc„
6G C. pee.f
/.9
Received By: % Date: _ —CY
Issued By:
iWte
Date: / – 7- 0/
•
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
RECEIVED
JAN 5 2001 ON-SITE SEWER/WELL PERMIT APPLICATION
Municipanty tat Anchorage. FOR A SINGLE FAMILY DWELLING
Parcel ID O.S/— 793-/4
Permit Number SWo/OocS
Property owner(s) Turner Construction Day phone 242-4555
Mailing address (1) PO Box 3487, Palmer, AK
Mailing address (2) Jip Code 9 9 6 4 5
Legal description (Lot, Block & Sub'd.) Lot 10, Block 2, Glenn View Estates West PL/ 1
Legal description (Section, Township & Range)
Lot Size 40.000+
Acres/Sq.Ft. Number of Bedrooms 4
THIS APPLICATION IS FOR:
Sewer Only ® Well Only
Sewer and Well 0 Water Storage
Sewer Upgrade ❑
THIS PROPERTY CONTAINS:
Hot Tub ❑ Jacuzzi
Swimming Pool 0 Water Softening Unit
Therapy Pool 0
E
certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
��ssalM-tee �� d
(Signature of property owner or a fed agent)
Permit Fees:
Date of Payment:
Receipt Number:
(Rev. 12/00)
(3&(e,Sil
Waiver Fees:
Date of Payment:
Receipt Number:
KIND ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
(907)696-6111/FAX (907)696-8111
January 4, 2001
Municipality of Anchorage
Dept. of Health & Human Services
On -Site Services Section
P. O. Box 196650
Anchorage, Alaska 99519-6650
Subject: New On-site Sewer Permit — Glenn View Estates West S/D, Block 2, Lot 10
Gentlemen:
The owner has requested we proceed forward to obtain a septic permit on the subject
lot. One testhole was dug and percolation test conducted on April 20, 1999 and April
22, 1999 respectively. The result of this test is attached. An additional testhole will
be dug prior to construction of the proposed system. The general slope of this lot is
from north to south at a grade of approximately 0 — 3% as indicated on the drawing.
We have designed our system utilizing an absorption rate of 0.6 gpd/sf for the 4 -
bedroom house, which is proposed for this lot. The lot will be served by public
water.
We propose to install a 5' wide shallow trench. The soils consistently percolate at 20
minutes per inch and the material appears to be uniform per the soil. Water was
not encountered during the excavation or monitoring.
There are no public or private wells within 200' of our proposed system location
except as noted. There is no surface water within 100' of the proposed system and
there are no known curtain drains within 50'. We do not expect there to be any
adverse effect on adjacent lots by the development of this system.
If you have any questions, please contact me at 696-6111/FAX 696-8111.
Respectfully submitted,
IKNIU Engineering
enneth M. Duffus, P.E.
Attachments: On -Site Well and Sewer Application
Wastewater Absorption System Details/Site Plan
Soils Log/Percolation Test
'WELL &
NT
WASTEWATER DISPOSAL SYSTEM DETAILS/SITE PLAN
GLENN VIEW WEST S/D, LOT 10, BLOCK 2
OT u ) i VACANT
l Ir
VOYLES A ENUE
Lot 12
Lot 11
Lot 14
NO PUBLIC WELLS WITHIN P07 IT
PROPOSED SYSTEM.
PO PRIVATE WELLS WITHIN P00' Of
PROPOSED SYSTEM EXCEPT AS NOTED.
NO SEPTIC SYSTEMS VITHIN P00' d'
PROPOSED WELL EXCEPT AS NOTED
isS ..OF. ALgs
KEN DUFF
1
CE -7116
%
AyA"^ 0� SS10'
Lot 9
DESIGN DETAILS
4 BDRM X 150 GPD = 600 GPD
600 GPD/0.6 GPD PER SO. FT. (20 MIN/IN.)= 1000 S0. FT
(1000/5'(V)) X .50(RF) (4.0' GRAVEL) = 100 FT. TRENCH
USE 1 TRENCH - 100 CO X 5' (V) X 4.0'(D)
Total depth of system is 6.0' from original grade.
Total depth of gravel below distribution pipe is 4.0' ,
NOTES:
1. USE 1250 GAL. SEPTIC TANK. INSULATE IF <4' OF COVER.
2. INSULATE TRENCH WITH 2' HD BURIAL FOAM.
3. CONTRACTOR WILL ENSURE MINIMUM 2% SLOPE INTO SEPTIC TANK.
4. ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TO ACHIEVE
MIN. 3' COVER IF REQUIRED.
5. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT
WELLS L SEPTICS.
VACA
Lot 1
Lot 2
Lot 3
PREPARED FOR:
TURNER CONSTRUCTION
P.O. BOX 3489
PALMER, AK. 99645
242-4555
Scale: 1'= 100'
PAGE 1 OF 2
FIELD BOOKS
Ca+urm:
B01"'D"R" LANG
ORAwc VBG
ram= LANG
ocaEa KMD
ASRua. LANA
CNC Mt.
DATE: 1 /4/41
END ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
°113'NW1459
ACRO nU 01001.DWG
'08 NN` 01001
(907)696-6111/FAX (907)696-8111
KND
WASTEWATER DISP❑SAL SYSTEM DETAILS
GLENN VIEW WEST S/D, LOT 10, BLOCK 2
PROPOSED SERVE S
TEM
///A
MT PROP
ED PRIMARY SYSTEM
CO
PROPOSED 12'
GAL. S.T.
FCD
47.0'
0
0
cPlC❑
MT
6.0
KENNETH N. DIM
CE -7118
5
"rEss10‘'
\aNN`__e*
crl
0 27.0'
29.0'
•PROP❑SE
•DR1�
2.8' HOME
-1.3'
- 4.2'
29.2'
75.'
15.5'
-O
PREPARED FOR:
TURNER CONSTRUCTION
P.O. BOX 3489
PALMER, AK. 99645
242-4555
TH#KND9
2/10
Scale: 1'= 20'
PAGE 2 OF 2
F 0 800Ks
"HUED
"u""" LANG
""Ave VBG
STMC*G LANG
°coup KMD
"g"`" LANG
"it 1/4/01
lEAV D ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER. AK 99577-8736
".C. FILE:
o • NW1459
"C"" C L 01001.DWC
a "" 01001
(907)898-8111/FAX (907)898-8111
•
!CND ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
SOILS PERCOLATION TEST
Performed for: Arctic Devco
Project:
1-
2-
3-
4-
5-
6-
7-
8-
9-
10-
11-
12-
13-
14-
15-
16-
17-
18-
19-
20-
Depth
(Feet)
Org
�Ps� OF Atqs 11
iliF1
0*�di C2 04, N it *
1
p .a.. '� _..
0
r
0 re ' Kennet.. Dut q . t�
CE 7116 J'aG"%
Date Performed: 4/20/99
Lot 10, Block 2, Glenn View West TEST HOLE # 99-2(10
GM —w/ boulders to 3' , loose to
med. density
Increasing density w/ depth
tight at bottom
BOH
SEE ATTACHED SITE PLAN
FOR HOLE LOCATION
Was Ground water encountered? No
Depth to water atter monitoring? NO
What depth? NA
Date? 05/15/99
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
1
4/22/99
12:40
-
6"
-
2
110
30 min
47/16"
19/16"
3
110
-
47/16"
-
4
1:40
30 min
215/16"
18/16"
5•
1:41
-
6"
-
6
2:11
30 min
48/16"
18/16"
•
Water
Added
Percolation Rate 20.00 (min/in) Pere Hole Diameter 6"
Test Run Between 3.5 feet and 4.5 feet
I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in
effect on this date.
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 Elmore Road
P.O. Box 196650 Anchorage, AK 99519-6650
www.d.anchorage.ak.us
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
CosA# 615C/a /3360
Parcel I. D. 051 —793-14
1. GENERAL INFORMATION
Complete legal description
Expiration Date:
/
GLENN VIEW ESTATES WEST, PHASE #1; BLOCK 2,
LOT 10
Location (site address) 21322 PAULA SUE CIRCLE, CHUGIAK, AK, 99567
Current Property owner(s) WILLIAM & MAIKE HENNING
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing address
Day phone
21322 PAULA SUE CIRCLE, CHUGIAK, AK, 99567
C/0 AGENT
Day phone
BARBARA CRITTENDEN W/ PRUDENTIAL Day phone 242-2227
16635 CENTERFIELD DRIVE, EAGLE RIVER, AK, 99577
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 4
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
TYPE OF WASTEWATER DISPOSAL:
❑ Individual On-site
❑ Individual Holding tank
❑ Community On-site
■ Public Sewer
•
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems
Approval are valid for 90 days from the date of issue for p pperties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my sea! affixed hereto and as of the validation date shown below, 1 verify that my
investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances. and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179
Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
Engineer's Comments:
In conducting this evaluation. GEG, LtD. attempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines & Regulations. The reported results described the performance of the
system unde" the conditions encountered at the time of the test, and separation
distances measured to readily identifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will it confer any legal right whatsoever.
5. DSD SIGNATURE
rl Approved for 11' bedrooms.
Disapproved.
Conditional approval for
Date `8'6/11
AOF��`��
ey A. orness,
CE 7953 1•p-
Prof essiono"c
040000��
t'IOFf Citffr ((
J2 ON-SITE
�Z WATER AND
5- WASTEWATER ^
PROGRAM pr
z,,.."
bedrooms, with the following stipulations:
9
l�l11)1111111\\
Attachments:
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
Original Certificate Date r _1 0 1—Z
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.orglonsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: GLENN VIEW ESTATES
A. WELL DATA
Well type
Date completed
Total depth ft. Cased to
FROM WELL LOG
WEST PHASE #1; BLOCK 2, LOT 10 Parcel ID: 051-793-14
PUBLIC WATER
If A, B, or C provide PWSID#
Sanitary seal (Y/N)
Date of test
Static water level ft. ft
Well production g.p.m. g p m.
WATER SAMPLE RES
Well Log (Y/N)
Wires properly protected (Y/N
ft Casing height (abo
ATI CTION
round) in.
Coliform colonies/100 ml. Nitrate mg./L. Collected by:
nic
ug /L. Date of sample:
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material
SEPTIC/STEEL
Date installed 1/12/2001
Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) YES
Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) N/A
Date of pumping 6/29/2012
C. ABSORPTION FIELD DATA
Pumper
JR'S PUMPING
I*BELOW EXISTING GRADE
Date installed 1/12/2001 Soil rating.p.d./ or ft2/bdrm) 0.6
too & 17
Length 117 TOTAL ft. Width 5
System type 5—WIDE TRENCH
ft. Gravel below pipe 2.91/3.03 ft
Total depth *7.3/7.0 ft. Eff. absorption area 1008 ft2 Monitoring tube YES Depression over field NO
Date of adequacy test **8/3/2012 Results (Pass/Fail) PASS
Fluid depth in absorption field before test 2 in.
For 4 bedrooms
Water added 780 gal. New depth11 0 in.
Elapsed Time: 130 min. Final fluid depth 8 in.
Absorption rate >= 600+ g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date —
**TESTED 100' TRENCH ONLY. 17' TRENCH HAD 23" OF LIQUID UPON INSPECTION.
D. LIFT STATION
Date installed Size in gallons
"Pump on" level at in. "Pump off' level
Datu Cycles tested
Manhole/Access (Y/N
High water alarm level at in
Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot On adjacent lots
Absorption field on lot On adjacent lots
Public sewer main
Sewer /septic service line
F.
ontainment areas
PUBLIC WATER
sewer manhole/cleanout
Holding tank
Manure/animal excrete storage areas
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 51+
Absorption field 5'+
Water main 10'+ Water service line 10'+ Surface water 100'+
Wells on adjacent lots 200'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation 10'+ Water main 10'+
Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+
Curtain drain NONE KNOWN
COMMENTS
G. ENGINEER'S CERTIFICATION
Wells on adjacent lots 200'+
I certify that t have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this
date.
Engineer's Printed Name JEFFREY A. GARNESS
Date
ess.
CE 7 53 •` vp�
• t• 0
Prof essioCoo
COSA Fee $
(-1q0- w
Date of Payment
Receipt Number
(Rev. 11/05)
X/ 9/fa
CL/SSYt)
Waiver Fee $
Date of Payment
Receipt Number
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
sivic/
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D D.57— 7q 3 - /Y
1. GENERAL INFORMATION
Complete legal description
Location (site address)
Current Property owner(s)
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing address
CosA# ORO 12
Expiration Date: 5 5 — 0 CI
GLENN VIEW ESTATES WEST PHASE 41; BLOCK 2, LOT 10
21322 PAULA SUE CIRCLE •CHUGIAK, AK
LARRY & DEBBIE WHETHAM Day phone C/O AGENT
21322 PAULA SUE CIRCLE •CHUGIAK, AK
Day phone
BARBARA CRITTENDEN W/ PRUDENTIAL Day phone 242-2227
16635 CENTERFIELD DRIVE *EAGLE RIVER, AK 99577
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
•
4
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding tank
Community On-site
Public Sewer
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also Issues COSAs upon request to homeowners. Certificates of On -Site Systems
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions In the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my
investigation, based on procedures outlined 117 the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179
Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
. Engineer's Comments:
In conducting this evaluation, GEG, LtD. attempted to provide a thorough,
conscientious engineering analysis of the system In accordance with ADEC and MOA
DSD Guidelines & Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the fest, and separation
distances measured to readily identifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory fest
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to moot the
operational requirements of the ADEC or MOA DSD. The content of this report is for
the solo benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will it confer any legal right whatsoever.
5. DSD SIGNATURE / I
Approved for T bedrooms.
Disapproved.
Conditional approval for bedrooms, with the fllowing stipulations:
Date 4130/2./,06
vd
0
y ess: O
CE -79 m**opt
.!1/30
�000�'�ecY 0Fff r�i,
C
�.Q -...... ••h''o
j=: • ON-SITE • • 07:
WATER AND Tr'=
WASTEWATER =
PROGRAM
Attachments:
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
By
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Reort
Other
(Rev. 11/05)
Original Certificate Date: S 3_— O C?
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: GLENN VIEW ESTATES WEST #1; BLOCK 2, LOT 10
A. WELL DATA
Well type PUBLIC If A, B, or C provide PWSID# N/A,
Date completed Sanitary seal (Y/N)
To . • Cased to ft.
FROM WELL LOG
PUBLIC WATER
Date of test
Static water level ft.
Well production
WATER SAMPLE RESULTS:
g.p.m.
Parcel ID: Dsl— 7 9'3 -11
Well Log (Y/N)
Coliform colonies/100 ml. Nitrate mg /L
Arsen' ' ate of sample:
B. SEPTIC/HOLDING TANK DMA
Tank Type/Material SEPTIC/STEEL
Tank size 1250 gal Number of Compartments _2
Foundation cleanout (YIN) YES Depression over tank (Y/N) NO
er y protected (Y/N)
Casing height (above ground) In.
AT INSPECTION
:p;m.
Date of pumping
4/14/08
C. ABSORPTION FIELD DMA
Other bacteri
Collected by:
Date installed
1/12/01
Cleanouts (Y/N) YES
High water alarm (Y/N) N/A
Pumper JRS PUMPING
I•BELOW EXITING GRADE
Date Installed 1/12/01 Soil rating (g.p.dJft'o
Length 100/17 ft
0_6 System type 5—WIDE
Width 5 ft.
Total depth "7.25 ft. Eff. absorption area 1008 ft'
Gravel below pipe 2.91/3.03 ft
Monitoring tube YES Depression over field NO
Date of adequacy test "4/28/08 Results (Pass/Fail) PASS
Fluid depth In absorption field before test ""DRY in Water added 720 gal.
Elapsed Time: 60 min. Final fluid depth 4 in
Absorption rate >=
For 4 bedrooms
New depth 10 in.
600+ g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date —
"TESTED THE 100 FOOT TRENCH. ***NOTE: THE LIQUID LEVEL IN THE 17 FOOT TRENCH ON
(4/28/08) WAS 14 INCHES BELOW THE INVERT.
D. LIFT STATION
Date installed
"Pump on" level at in
Datu
Size in gallons
"Pump offlevel
Cycles tested
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot
Absorption field on lot
Public sewer main
Sewer /septic service line
Ani . ment areas
Manhole/Access (Y/N
High water alarm level at in.
Meets alarm & circuit requirements?
On adjacent lots
On adjacent lots
wer manhole/cleanout
Holding tank
Manure/animal excrete storage areas
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+
Water main
Wells on adjacent lots
Absorption field
5'+
10'+ Water service line 10'+ Surface water 100'+
200'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+
Building foundation 10'+ Water main 10'+
Water service line 10'+ Surface water 100'+
Curtain drain NONE KNOWN
F. COMMENTS
G. ENGINEER'S CERTIFICATION
Wells on adjacent lots 200'+
I certify that 1 have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this
date.
Engineer's Printed Name
Date L4 -!)o /lou 9,
JEFFREY A. GARNESS
Driveway, parking/vehicle storage
10'+
COSAFee$ / 30• la°
Date of Payment '1� 3 Clog
Receipt Number 103 5%0
(Rev. 11/05)
Waiver Fee $
Date of Payment
Receipt Number
07/10/01 OED 12:19 FAS 0000100
•INSIN Mm.
141
Lot 11
VISTA REAL ES7AIY rat «+
.
V 0
ROSS VOYLES AVENUE
5 09•50'03111 Ik0.01'
15'TELEcow. 0•
ELECT. EASEMENT
SEPTIC
SEAN ours
a>•Tia^
WOuo
Frslplw..
7
fill J
Int 10
40.00.0 ..f.
N /Y50'al'E
150.10'
1
Lot 9
30.00'
NJ 1 4
PLOT PLAN _ ASBUILT SCALE I' ' eC GRID NM 1458 Proi.ot No CD -254
Lang AffcC�Qtff� Ina.11500 Doryl Avenue, Anchoray., /Jaska
Registered Lot id Surveyors (907) 522—mss Phone
ax e
1 11ef•by .elegy N1.1 I Inn sunned the fain Nbyy d...RN
L.1 70. IMM 3. a DIN vuw *WsWMOIrL1 )W (Elsa 11'. bDOD�42)
M.Anep w�s Re.OMMN n,, Aka . NW e. roten t Anted
Minn .1. w*iM Kw Peen* One and w M nab .ms the property
d l.sM lard.. 0.0 Iw L..._nrll. M M. property gang dMe•nt M.nl-
.n.-..b M M. .l.w y.d M.N.. ed Mal N1.. .n no O.d..r.. Msnnll..wn
Ilnw N Star Noble 1..emwee .n mid M.bagr met ., Inested hereon.
ttt
Wed No t. 1t0 2•y .f T�ttl 112-1. d M.MnOe, Mask.
M 4 M. .1 IM owner N IMlennin. M. mistime' e1 any
n ormenfe. eennente, 14' I.Mr1.UIMN *MA 00 n.t Sable .n NM nwerd.d
subdivision plot
99515
it
=5b