Loading...
HomeMy WebLinkAboutGUDVEINA ESTATES LT 1Gudveina Estates Lot 1 #017-161-08 Municipality of Anchorage Page 1 of 3 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 Anchorage, Alaska 99519-6650 Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number. SWT00031 T PID Number. _. On- - I (P-1 — O6 Name: JACK BLAIR Wastewater System: ❑ New ■ Upgrade Address: 15540 BLAIR VIEW CIRCLE ANCHORAGE, AK 99516 ABSORPTION FIELD Phone: (907) 257-0159 No. of Bedrooms: 4 O Deep Trench ■ Shallow Trench O Bed O Mound f] Other LEGAL DESCRIPTION SA "°a"a 1.2 T°� 0. r°"6 °- apo/se. Ft 7.03 rL Lot: Block: Subdivision: 1 Dw% to pipe bots m frorrl wkpnol s^be an,r depul bsneaal pipe — GUDVEINA ESTATES 2.87 — 2.97 n 4.06 rt Township: — Range: Section: fy oddsd obww wlpkel prods: aro.sf wque — — 0.5'-1.0' fti 54 FL WELL: ❑ New ❑ Upgrade aw.. 5 NwRbw of fre 1 Detww. U.leee no.e _ FL it CbrrcWion Plwat% "c Tool 0. Cowed TW Talal eLsrgbn Ores Pqe wolwbk G n n 540 so. n ASTM D-3034/SCH 40 PVC D"ew: Dob Mists Stalk; waw levet h.tdNr: DENAU SEWER & DRAIN Dote katoswk 10/26/2000 n wRp set Au CaMrq fwpnt A#b"orwns: 7 app FL rL TANK SEPARATION DISTANCES 0Septic 0Holding ■S.T.E.P. To Septic Absorption uft Holding bac/Pdvote �° oci1MM1 aapochr in s., Prom Tank Field Station Tank s..w ue.. ANCHORAGE TANK 1500 Well 100'+ 100'+ 100'+ — 25'+ STEEL d wo2a+a e Surfac Water Water 100'+ 100'+ 100'+ — — LIFT STATION Lot 5'+ 10'+ 5'+ — — 1500 ANCHORAGE TANK ORENCO SYSTEMS Foundation 5'+ 10'+ 5'+ — — W42»a 42+ eb q ft " .e1w a1gn4fi Curtain Drain NONE KNOW fierq llolw a Yoa,k ascukd k+Peausrw pwfem+d W. 20 OSI OS HHF M.O.A. Remarks: 1. EXCELLENT SOILS IN TRENCH. BENCH MARK toaodon aoa Deevlpaom 2. PERK TEST IN TRENCH BOTTOM: 5 GALLONS TOP OF MANHOLE LID. IN 16 MI 3. NO GROUNDWATER WAS ENCOUNTERED WHEN AsftW.e a..auare 96.96 FL THE SEPTIC TANK WAS SET. eflorlcelrs WAL 4. BOTTOM OF TANK IS 13'+/— BELOW GRADE. Inspections performed by: AWWC, INC. Dates: 1st 10/26/2000 °,;, , �* .0� 2nd to 4th 10/26/2000 D 5th 11/3/2000 OQ p e fr A Ga Hess 0 Department of Health and Human Services approval -i43 �p�. ' Reviewed and approved by 4/ Date: 2 • s- 01 •. .Foy �44e0yPrafessioNa\��� -017 Rev, 9/01) wal 25 v // PERMIT NUMBER: PARCEL ID UMBER SW000377 REVISED AS -BUILT DRAWING 017-1617-087 EXISTING DRAINFIELD TO BE USED AS A RESERVE SITE E. 156 AVENUE IS BELIEVED THAT PRESSUf LINE CONNECTS TO 4- C/O THAT RUNS TOWARDS OLD DRAINFIELD. GARNESS ENGINEERING GROUP, Ltd,* . - 4 1 1 11 1 - I c --- " I CONSULTANTS & GENERAL CONTRACTORS .. ....... - ,, ...... ... .. 370I E. NDCR RW. SUM 101 - MCHOWE, W 99507 - PHONE (907)337-6179 * FAX (907)336-3218 WEBSITE : PREPARED FOR: PHONE NUMBER: PACE NUMBER:... JACK BLAIR (907) 257-0159 1 OF 1 ff LEGAL DESCRIPTION: DRAWN BY: GUDVEIINA ESTATES SUBDIVISION; LOT 1 PNB TYPE OF WORK: DATE: REVISED AS -BUILT OF SEPTIC SYSTEM UPGRADE 12/16/11 SCALE: Q _7 =-795 710....'. A B ST1 101.3 59.8 ST2 109.6 68.4 loo' WELL RADIUS MH 111.2 70.1 WELL (POINT A) Dl 101.2 49.3 D2 102.4 49.9 C/O PIPE WHICH HEADS FOUR TOWARDS OLD DRAINFIELD MT1 104.3 80.0 EXISTING BEDROOM HOUSE 74 MT2 136.1 85.1 Tl 4 K I tiNZ i NEW DRAINFIELD 30 IN UTILITY ROOM POINT B IS ON THE END OF THE LOG (18" FROM CORNER OF HOUSE), C/O BELIEVED TO HEAD MT2 TOWARDS OLD DRAINFIELD. 0 EXISTING DRAINFIELD TO BE USED AS A RESERVE SITE E. 156 AVENUE IS BELIEVED THAT PRESSUf LINE CONNECTS TO 4- C/O THAT RUNS TOWARDS OLD DRAINFIELD. GARNESS ENGINEERING GROUP, Ltd,* . - 4 1 1 11 1 - I c --- " I CONSULTANTS & GENERAL CONTRACTORS .. ....... - ,, ...... ... .. 370I E. NDCR RW. SUM 101 - MCHOWE, W 99507 - PHONE (907)337-6179 * FAX (907)336-3218 WEBSITE : PREPARED FOR: PHONE NUMBER: PACE NUMBER:... JACK BLAIR (907) 257-0159 1 OF 1 ff LEGAL DESCRIPTION: DRAWN BY: GUDVEIINA ESTATES SUBDIVISION; LOT 1 PNB TYPE OF WORK: DATE: REVISED AS -BUILT OF SEPTIC SYSTEM UPGRADE 12/16/11 SCALE: Q _7 =-795 710....'. PERMIT AS-BUILT DRAWING PARCEL017ID NUMBER: 017-161-08 FINN. am - 95.75+/- 511 5f2 Moi TOP OF f" Af I=- 81.74 NSW 1500 6& ON mff F SIT,�,p, TANK Af fimu INkf -86,96.9 4 C MP 6UPIAL TANK) PMcRM-9717+ r6TUM! =om or m"W fU - 6967 .4.. • Nv of PPE (I251, M55a PPE) - 95.73 11/15/2000 DRAWN BY: AUkSI01 WMER & AVASTEINTSTER K.D.W. CONSULTANTS, INC. SCALE: 6901 DEBARK ROAD SUITE 29 • ANCHORAGE AK 99504' PHONE (907)337-0179 • FAX (907)339-5246 1 w - 30, PREPARED FOR: PHONE NUMBER: PAGE NUMBER: JACK BLAIR (907) 257-0159 3 OF 3 LEGAL DESCRIPnON: GUDVEINA ESTATES SUBDIVISION; LOT 1 TYPE OF WORK AS -BUILT PROFILE SEPTIC SYSTEM UPGRADE fOr Of MMM - 96.96 � for OF f" Af ODUf - 87BI 9RITA ..... ....... �. S. 7953 :i t MUNICIPALITY OFANCHORAGE ID, 45-0005; 50pfr) Department of Health and Human Services On -Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Permit Number: SW000377 Date Issued: Sep 14, 2000 Expiration Date: Sep 14, 2001 Parcel ID: 017-161-08 Legal Description: GUDVEINA ESTATES LT 1 Design Engineer: 0041 AK Water & Wastewater Consultant Site Address: 015540 BLAIR VIEW CIR Owner Name: Jack Blair Lot Size: 52513 SO. FT. Owner Address: 15540 Blair View Cir. Total Bedrooms: 4 Permit Bedrooms: 4 Anchorage . AK 99516 - This permit is for the construction of: r,/ Disposal Field Q Septic Tank E] Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. IO —ZS -00 SEE E,vG/NE&? ?'l /9AjE,vpE,V DESI&Al D,#Tzo Received By: Issued By: 10-2-4'-00 r -OR A RE05516-NEQ WJ�STet✓r9TE/? SYSTEM, Date: /' 2 Z -00 Date: 1-- D ALASKA WATER F� WASTEWATER CONSULTANTS, INC. October 24, 2000 Municipality of Anchorage Department of Health & Human Services Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Well and Septic Design for Gudveina Estates; Lot 1 (Revision of permit # SW000377) To whom it may concern: The existing 4 bedroom house is currently served by a private well and septic system. The existing drainficld is in a state of failure and in need of an upgrade prior to the sale of the house. During the installation of the previously permited design, groundwater was encountered preventing the installation. A revision of the design is now necessary. One test hole was performed by Leroy C. Reid Jr. P.E. on 9/10/86 on the cast portion of the property. The proposed septic system will be designed within the 30 foot radius of this test hole. We are proposing that a 1500 gallon S.T.E.P. tank and a five foot wide drainficld be installed. Comments regarding the proposed design are summarized as follows: 1. SOILS: See the attached log which shows the soil classifications, groundwater monitoring, and a visual soil rating of 125 ft2 per bedroom. A percolation test will be performed on the day of construction to confirm the rate of absorption. 2. TRENCH DESIGN: a. Allowable Application Rate: 1.2 gallons/day/ft2 b. Number of Bedrooms: 4 c. Design Flow: 600 gallons per day d. Minimum Absorption Area: 500 ft2 e. Total Depth: 7 feet (max.) f. Effective Depth: 4 feet g. Width: 5 feet h. Reduction Factor: 0.5 i. Minimum Length: 52 feet long j Effective absorption area = 520 ft2 6901 Debarr Road, Suite 2B * Anchorage, AK 99504 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwc.com 3. SURFACE NVATERS: There are no surface waters within 100 feet of the proposed upgrade. 4. TOPOGRAPHY: As can be seen on the attached topography site plan, there are no slope concerns. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. A E., M.S. NOTE. Attached is a site plan drawing, a design drawing, a topography site plan, one soil log, and a 7 page construction specification letter which are all part of the design package for this septic system. 6901 Dcbarr Road, Suite 2B * Anchorage, AK 99504 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Wcbsite: akwwc.com REXVIEW TERRACE S/D LOT 3 rVArAtiT� I I I I I I I I I I I I I I I I I I I I I I L_ jr— ] *THOI GUDVEINA ESTATES S/D LOT 3 GUOVEINA ESTATES S/D LOT 2 /EXISTING FOUR BEDROOM HODS ORIGINAL AREA FORS' IInFc+Ai UPGRADE REVISION DUE TO HIGH GROUNDWATER LEVELS I i I = EXISTING SEPTIC 1 A�BAENDONDED — — ....j*} ,. — — — — — — — — — — — — — — E. 156 AVENUE _______________ SHERWOOD HEIGHTS S/D LOT 2 SHERWO00 HEIGHTS S/D LOT 3 � COLDENVIEW HEIGHTS S/D I LOT 1A I �+ `-VACANT I r----------- BY LEROY C. PE ON ti II GUDVEINA ESTATES S/D I LOT 7 GUDVEINA ESTATES S/D LOT 6 CAC -WD JR. GUDVEINA ESTATES S/D ��LLO+OT S WACANTT r FOR DETAILS. `--------------' GOLDENVIEW HEIGHTS S/D LOT 2 T 10/24/00 (REV) i i� -• DRAWN BY: ALASIU NVATER & %"TENVATL'R K.D.W. 0 CONSULTANTS, INC. Ste' �* .... . ............. 6901 DEBARR ROAD, SUTE 29' ANCHORAGE AK 99504 • PHONE (907)117-0179' FAX 907)756-7246 PREPARED FOR PHONE NUMBER: PAGE NUMBER: v� JACK BLAIR (907) 257-0159 1 OF 2 �;1ti• p,• ass; LEGAL DESCRIPTION: �4q �• •• -7953 is GUDVEINA ESTATES SUBDIVISION; LOT 1, �V� a ' N IYPE OF WORK: y rofessto�°: SITE PLAN FOR REVISED DESIGN OF SEPTIC SYSTEM UPGRADE `.^,fes p(ISTLNG FOUR BEDa00M HOUSE EXISTING SEPTIC TANK-/ TO BE COMPLETELY / ABANDONED / TEST HOLE PERFORMED BY LEROY C. REID, JR. P.E. ON 10/9/88 EXISTING DRUNFIELD TO BE USED AS A RESERVE SITE E. 156 AVENUE ALASKA NATER & NVASTENVXrER CONSULTANTS, INC. NO >01 DEBARR ROAD, SUTE 28 • AHORAGE, AR 99504' PHONE(907)3376179 - FAX (907)335-324, :PARED FOR: PHONE NUMBER: JACK BLAIR (907) 257-0159 GUDVEINA ESTATES SUBDIVISION; LOT 1 DESIGN REVISION OF SEPTIC SYSTEM UPGRADE 1 I I I -INSULATE LINE UNDER DRIVEWAY WITH 4' WIDE BLUE BOARD. I/ PROPOSED 1500 GALLON S.T.E.P. / I L TANK UAL UT ET5 11 -PROPOSED DRAINFIETD. EXCAVATE A TRENCH THAT IS 7 FEET DEEP, BY 5 FEET WIDE, BY 53 FEET LONG. ADD 4 FEET OF CLEAN. WASHED SEWERI DRAINROCK. INSTALL DOUBLE CLEANOUTS K.D.W. LE: {, I" = 30• 2OF2 ALASKA W C. I SOIL LOG - PERCOLATION TEST I `¢ j; 8/14/2000 LEGAL DESCRIPTION: GUDVEINA ESTATES SUBDIVISION; LOT 1 " """ "' " PRESOAKED FOR 4 HOURS PRIOR TO TESTING. 1 1:26 PERFORMED FOR: JACK BLAIR 6. %//% "A. DATE PERFORMED: 8/14/2000 0o e' J f ,q ' Gamess;' —7953 DEP (fee TM ORGANICS TEST HOLE #1]0��4°^Odprofeselol\oa�� 1:56 \F »y�_ I 4�004000�� 1 (PAGE 1 OF 2) Irnk`_` I YN� • 9-E 10- 11 B.O.R 12- 13- 14- 15- 16- 17- 18- 19- 20— COMMENTS: 21314151617181920COMMENTS: 60 GM ML GM DEPTH TO GROUNDWATER DATE SEEP ® 9.0' 8/14/2000 9.1' 8/22/2000 i \ I PRESOAKED FOR 4 HOURS PRIOR TO TESTING. 1 1:26 SURE 6. %//% 2 1:56 30 MIN. N a • 3 1:56 IIIIII { I � r zz-04ii 30 MIN. Irnk`_` I YN� • i 6. -------------- DEPTH TO GROUNDWATER DATE SEEP ® 9.0' 8/14/2000 9.1' 8/22/2000 i \ I PRESOAKED FOR 4 HOURS PRIOR TO TESTING. j 11! I j SITE PLAN \` / I' = 100' \\ I 1 I �lLW1.L3EOD' �IIl$� elle, 1 WATER LEVEL READING i \ I PRESOAKED FOR 4 HOURS PRIOR TO TESTING. 1 1:26 6. — 2 1:56 30 MIN. 1 1/2' 4 1/2- 3 1:56 { I 4 2:26 30 MIN. 2 1/2- I 5 2:26 i 6. -------------- 6 2:56 E. 156 AVENUE DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 8/15/00 SOILS PRESOAKED FOR 4 HOURS PRIOR TO TESTING. 1 1:26 6. — 2 1:56 30 MIN. 1 1/2' 4 1/2- 3 1:56 6. — 4 2:26 30 MIN. 2 1/2- 3 1/2- 5 2:26 — 6. — 6 2:56 30 MIN. 2 1/2- 3 1/2 - PERCOLATION RATE 8.6 (MIN./INCH) TEST RUN BETWEEN 2.5 FTS AND�7 PERCOLATION DATA ON THIS PAGE FOR UP ER B F3i�R11, PERFORMED BY ALASKA WATER & WASTEWATER I, THIS WAS PE F(JRMED IN ACCORDANCE WITH ALL STATE DATE: q !/OJ HOLE DIA. 6' (INCHES) kilm CERTIFY THAT I IN EFFECT ON THIS ALASKA WATER & WASTEWATER CONSULTANTS. INC. I SOIL LOG — PERCOLATION TEST I LEGAL DESCRIPTION: GUDVEINASUBDMSION; LOT 1 PERFORMED FOR: JACK BLAIR DATE PERFORMED: 8/14/2000 DEPTH (feet) TEST HOLE #1 1 (PAGE 2 OF 2) 7- CA e 0 0 9 W C� 10 a w 11 w N 21314 12- 13- 14 15- 16- 17- 1 8 5161718 19 20 COMMENTS: PERFORMED BY THIS WAS PERF DATE: t DEPTH TO DATE GROUNDWATER SEE PACE 1 OF 2 I 4 fE I i i I SITE PLAN i I' = 100' j `I I 1 CLOCK TIME foo' x�� eni is I NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 8/15/00 SOILS I 1 � GW :=z=z: •- � i' — 2 I IIIIIIIIIML --- 2 5/8- I 11:111!11 II CL — i 2:27 30 MIN. GCNNN • 5 2:27 E. 156 AVENUE — IIIIIIIIIMH 2.57 30 MIN. 3 11/16' 2 5/16' //%CH RIIIIZI;S M X • SC 7- CA e 0 0 9 W C� 10 a w 11 w N 21314 12- 13- 14 15- 16- 17- 1 8 5161718 19 20 COMMENTS: PERFORMED BY THIS WAS PERF DATE: t DEPTH TO DATE GROUNDWATER SEE PACE 1 OF 2 I 4 fE I i i I SITE PLAN i I' = 100' j `I I 1 CLOCK TIME foo' x�� eni is I NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 8/15/00 SOILS I 1 � . I � i' — 2 I 30 MIN. --- 2 5/8- I 1:57 II 6- — i 2:27 30 MIN. 3 5/8' 2 3/8- 5 2:27 E. 156 AVENUE DATE READING CLOCK TIME I NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 8/15/00 SOILS PRESOAKED FOR 4 HOURS PRIOR TO TESTING. 1 1:27 6. — 2 1:57 30 MIN. 3 3/8' 2 5/8- 3 1:57 — 6- — 4 2:27 30 MIN. 3 5/8' 2 3/8- 5 2:27 6. — 6 2.57 30 MIN. 3 11/16' 2 5/16' PERCOLATION RATE 12.2 (MIN./INCH) j PERC. HOLE DIA. 6' (INCHES) TEST RUN BETWEEN 4.0 FT. May[4.5 FT. WATER & WASTEWATER 1. IN ACCORDANCE WITH ALL CERTIFY THAT :T ON THIS PHONE (907) 337-8179 • FAX (907) 338-3246 SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: GUDVEINA ESTATES SUBDIVISION; LOT 1 PERFORMED FOR: JACK BLAIR DATE PERFORMED: 8/14/2000 DEPTH TEST HOLE #2 (feet) 3a3� ORGANICS 1 (PAGE 1 OF 2) SOIL CLASSIFICATIONS 2 SM GW - ---- ORG Zp 5 j 6 ti.ar. 7 Y ��Y B Y•' 1• _b i•. .moi•.. ,moi•:• 10 •'^ti B.O.H. 12- 13- 14- 15- 16- 17- 18- 19- 20 21314151617181920 COMMENTS: PERFORMED BY THIS WAS PER DATE: Cf GM — GRAINY.�SW111111111MH 11.111!11//%CL GCNHN • 8/14/2000 7.4' qo� SP//%CH NET DROP (INCHES) !r��i�l�lZli��� • ifH j2� L.v.�Sc I GW TO GW/GM DEPTH TO GROUNDWATER DATE 9.0' 8/14/2000 7.4' 8/22/2000 I WATER LEVEL I READING NET DROP (INCHES) 8/15/00 SOILS PRESOAKED C. ifoo' i SITE PLAN 100' i emus I �H!1 1 I CLOCK TIME I NET TIME (MINUTES) I WATER LEVEL I READING NET DROP (INCHES) 8/15/00 SOILS PRESOAKED ifH j2� 4 HOURS PRIOR TO TESTING. I I — I 1 �J 2 E. 156 AVENUE DATE READING I CLOCK TIME I NET TIME (MINUTES) I WATER LEVEL I READING NET DROP (INCHES) 8/15/00 SOILS PRESOAKED FOR 4 HOURS PRIOR TO TESTING. 1 1:28 — 6" — 2 1:38 10 MIN. 2 1/2" 3 1/2 3 1:38 6" — 4 1:48 10 MIN. 2 1/2" 3 1/2- 5 1:48 — 6" — 6 1:56 1 10 MIN. 2 5/8" 3 318- 7 1:58 — 8 2:08 10 MIN. 2 1/2" 3 1/2- 9 2:09 6" — 10 2:19 10 MIN. 2 1/2" 3 1/2- 11 2:19 6" — 12 2:29 10 MIN. 2 1/2" 3 1/2" PERCOLATION RATE 2.9 TEST RUN BETWEEN 2.5 i WATER & WASTEWATER I, IN ACCORDANCE WITH ALL PERC. HOLE DIA. 6" (INCHES) 3.0 FT_ CERTIFY THAT ,T ON THIS ALASKA WATER & PHONE (907) 337-6179 • FAX (907) 338-3246 SOIL LOG — PERCOLATION TEST LEGAL DESCRIPTION: GUDVEINASUBDMSION: LOT 1 PERFORMED FOR: JACK BI -AIR DATE PERFORMED: 8/14/2000 (t at TEST HOLE #2 1 (PAGE 2 OF 2 7- DATE i SITE PLAN 1 1' - 100' � 1 SOIL CLASSI CATIO 1 OF 2 WATER LEVEL I READING NET DROP (INCHES) 8/15/00 SOILS 8 0 1 GW I •- 2 9:21 9 I i IlillllllMIL 9:21 i I — 4 11:111!11GM%///JJCIL --- i1 10' 5 I I 10' i GCHHN 9:33 • 0. 10' E. 156 AVENUE IIIIIIIIIMH SP CHZlI111l�SM1�'.d6� • Sc 7- DATE i SITE PLAN 1 1' - 100' � 1 I 04 1 OF 2 WATER LEVEL I READING NET DROP (INCHES) 8/15/00 SOILS 8 0 1 9:15 — ji 2 9:21 9 \ O ' i 16- 17- 18— DEPTH 61718 DEPTH TO GROUNDWATER DATE i SITE PLAN 1 1' - 100' � 1 I SEE PAGE 1 OF 2 WATER LEVEL I READING NET DROP (INCHES) 8/15/00 SOILS i1 I I i i I i i SITE PLAN 1 1' - 100' � 1 I r=00• WEII AM w. + NET TIME (MINUTES) WATER LEVEL I READING NET DROP (INCHES) 8/15/00 SOILS i1 � 1 9:15 — ji 2 9:21 �,2' \ O ' i 3 9:21 i I — 4 9:27 --- i1 10' 5 I I 10' i 6 9:33 , 0. 10' E. 156 AVENUE DATE READING CLOCK TIME I NET TIME (MINUTES) WATER LEVEL I READING NET DROP (INCHES) 8/15/00 SOILS PRESOAKED FOR 4 HOURS PRIOR TO TESTING. 1 9:15 — 10"- 2 9:21 6 MIN. 0. 10' 3 9:21 10w — 4 9:27 6 MIN. 0' 10' 5 9:27 — 10' — 6 9:33 6 MIN. 0. 10' 19 PERCOLATION RATE <1(MIN./INCH) PERC. HOLE DIA. 6' (INCHES) 20 TEST RUN BETWEEN 4.0 FT. 4.5 FT. COMMENTS: PERCOLATION DATA ON THIS PAGE FOR E RC HOLE ONLY. PERFORMED BY ALASKA WATER & WASTEWATER I, { / CERTIFY THAT I THIS WAS PERF/OR ED IN ACCORDANCE WITH ALL STATMUN AL GUIDELINES IN EFFECT ON THIS DATE: '71!002 11 .� Municipality of Anchorage Department of Health and Human Services 825 "L" Street Rick Mystrom, P.O. Box 196650 Anchorage. Alaska 99519-6650 Mayor http://www.ci.anChofage.ak.us October 4, 2000 Jeffrey Gamess Alaska Water & Wastewater Consultants, Inc. 6901 Debarr Road, Suite 2-13 Anchorage, AK 99504 Subject: Waiver Request for Gudveina Estates, Lot 1 Waiver Request #WR000070 Parcel ID #017-161-08 SW000377 Dear Mr. Gamess: Your request for a waiver of the required 10 feet horizontal separation from the on-site wastewater disposal system to property line has been approved. The approved separation distance is 1.0 foot. This waiver approval applies to the existing on-site wastewater disposal system to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-4744. Sincerely, citu� �• !��� Daniel J. R h Civil Engineer On -Site Water Quality Program 05/25/1995 00:52 9073459076 ALASKA ENVIRONMENTAL CONTROL SERVICES, INC. 1200 West 33rd Avenue, Suite B ANCHORAGE. ALASKA 99503 (901) 061.5060 JACK&JCAMIE BLAIR PAGE 04 Joe-- ,. d...:_ _ FN.+ ,• LaI / SHEET No. op CALCULATEDBY "`•' DATE CHECKED E• DATE well 401 190 _ Ra.u.a qn. _ ... ...../2� a:..s e'i: _. ne.,( .. '/��/, !'_.Laoo.�/a ..f.�. :. YG.OA Q' .. �.L ,rrl..•.. , _..__._...�:.. �. 05/25/1995 00:52 9073459076 JACK&JOINNE BLAIR Munlc4m ty of Anchorage DEPARTMENT OF HEALTH 6 HUMAN SERVICES 825 "L" Strut. Anchorage, Alaska 99502-0850 SOILS LOG — PERCOLATION TEST PERFORMED FOR: Col /i E XC•va A;.. • DATE LEGAL DESCRIPTION: _ Gadvoi.0 ES /ah'1 l.,r I Township. Range, Section: S"r 3Y T /s.v a 3W oEEP l•1 SLOPE SITE PLAN PAGE 10 1 1 1 1 1 2- 3- 4- 4 5 S1 9 u � �r..te 61•ck ' 1• SMA 7 8 9- 12- 13- 14 12 1314 is- is- 17- 18- 19- 20 518171fl1920 PERCOLATION RATE Immulwlncnl PERC HOLE DIAMETER TEST RUN BETWEEN PT AND FT COMMENTS so"I 'Iry r7 Z Pi -to AY it^%r ✓ft 11,r 044colrV 12.57 Q' l Z SP IZ5(3'/b .P:,,A BrM - 6rn .I WAS GROUNO WATER Ss�T told - ENCOUNTERED? c S 1�• F /A� rL f"P. S IF YES, AT WHAT L DEPTH? O E 10W@ M WaK Alar MwiwNO? Oal: im PERFORMED BY: /F E CS /•r • TEN 02)e -1 !/$ � . TIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE DATE: P� 72i00 (R". 4461 1Jepari.nenior L'nvironmentalwua1iiy n- n /"•.. v..v.•r+vr .-... ��..� \s./ .. 3500 Tudor Road — Pouch 6.650 N? 863 Anchorage, Alaska 99502 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM / �` mak" 1 PHONE MAILING ` /r� % A ,G —ADDRESS F� NAME / LOCATION / � �� eNt ��ibt"l" 4(//�e-='LEGAL DESCRIPTION SEPTIC TANK: NUMBER OF DISTANCE FROM WELL MATERIAL ��tCL COMPARTMENTS �a�cKitr Wil_ - LIQUID LIQUID CAPACITY �"� S�L GALLONS. INSIDE LENGTH INSIDE WIDTH DEPTH SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF PITS / OUTSIDE DIAMETER OR WIDTH �' LENGTH ` / DEPTH LINING MATERIAL �YVcI'�l� E' �Il .DISTANCE FROM WELL %,40 ,BUILDING FOUNDATION NEAREST LOT LINE TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) 1T� SQ. FT. TILE DRAIN FIELD: TOTAL LENGTH DISTANCE FROM WELLFOUNDATIt�'N �. - NEAREST LOT LINE OF LINES NUMBER OF L N€S DISTANCE BETWEEN LINES —TRENCH WIDTH y IN. TOTAL EFFECTIVE ABSORP ION AREA SQ. FT. LENGTH OF EACH LINE DEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE WELL'��'��ttr� DISTANCE FROM ��� WATER I TYPE DEPTH , BUILDING FOUNDATION. SAMPLE , NEAREST NEARESTSEPTIC SEEPAGE %�� OTHER LOT LINE SEWER LINE—, TANK SYSTEM CESSPOOL—, SOURCES_ DIAGRAM OF SYSTEM DISTAN DATE APPROVED ' Ct �B --T HEAe.rH AUTHORITY G 0. 0 ry h above ,,-_; true and correct,;; ff'/ m Ix MUNICIPALITY DEPT-:� OHEALTH H & WILSONWrLLDRILLING tNVjR6NMNTA_:N OV �:�1986 A 'ANCHORAGELASKA i icatp We advise' you -�to/attach this certificate -to your deed. ,, _x 7 'T Fff ...... . ...... � 0.1 k'_ A GREA`T'ER ANCHORAGE AREA BOR&UGH��0 DEPARTMENT OF ENVIRONMENTAL QUALITY PERMIT NO. 3500 TUDOR ROAD POUCH 6.650 ANCHORAGE, ALASKA 99502 TELEPHONE 279-8686 SEWAGE DISPOSAL SYSTEM — APPLICATION AND PERMIT NAME OF APPLICANT 1l�mer Ft i/z-e- MAILING ADDRESS � `/ PHONE INSTALLATION LOCATION LEGAL DESCRIPTION I ��IGL�IfE'�UItL/ L(„ INSTALLATION OF: SEPTIC TANK n SEEPAGE PIT ' DRAIN FIELD OTHER �5� ' �irtittit c2�ivC�ic/13�L��J C/✓c�J �i✓�1Yf�%��r/ TYPE AND SIZE OF FACILITY TO BE SEf�R'/V/ED FINANCED THROUGH ?n�G"'LG�'"� Tn BE INSTALLED BY SOIL TEST RESULTSEiLIC�Ltt! NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST G�Oi(/✓//L7j -- - - - COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION. /�2 SO � c(� SEPTIC TANK SIZE ,../ TYPE MINIMUM DISTANCES, REQUIREMENTS ,I-$ UI SEEPAGE AREA SIZE FOUNDATION TO SEPTIC TANK -1 FOUNDATION TO SEEPAGE PIT r 0 S DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK SEEPAGE PIT ,2DRAIN FIELD TO NEAREST LOT LINE. LAREA WELL TO SEPTIC TANK % o SEEPAGE PIT DRAIN FIELD ALSO CONSIDE LLS. WATER MAIN TO SEPTIC TANK DRAIN FIELD SEEPAGE PIT SEPTIC TANK, 5 SEEPAGE PIT �T DRAIN FIELD TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK ANO INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGPI-REGLiy_ATIONS REGARDING INSTALLATION. HEALTH AUTHORITY OR LICENSED DESIGNER DIAGRAM OF 1 1 CERTIFY THAT 1 AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIB D YSTEM IS IN ACCORDANCE WITH SAID CODE. / _67 DATE 6�L y APPLICANT'S SIGNATURE- Z9:21:6 TH.1 U 0` ORGANIC MATERIAL , 0.5 ORGANIC SILT 2` SILTY SANDY GRAVEL (GM :: Grey 5 :r Sfighfily PaAoisfi 4 SANDY GRAVEL (GYN) Grey Slightly Moist No seater table Note: Test hole excavated with tractor -mounted backhoe. Engineering 6) Geological Consultants /y ANCHORAGE FAIRBANKS ALASKA JUNEAU DATE 5- 24-72 SCALE I"= 2 DWN OY DAS 1 11.5` Werner F'itze Property LOG OF TEST HOLE Anchorage Alaska CHKO BY JI*VR IPROJ. NO. 26508 IDWG NO. A-01 oad�f. R&M ENGI,4EERiNG & GE®L®Gl&, CONSULTANTS 229 EAST 51st. AVE. — P.O. BOX 6087 — ANCHORAGE, ALASKA 99503 t TELEPHONE 907-279-0483 TELEX 090-35419 Civil Engineers Geologists Land Surveyors JAMES W. ROONEY, P. E. - _ RALPH R. MIGLIACCIO MALCOLM A. MENZIES, P.E., L.S. Engineering Geologist JAMES H. WELLMAN, P.E. May 25, 1972 Mr. Dick Marx Marx Excavating Box 10232 Anchorage, Alaska 99502 R & M No. 26508 RE: Test Hole and Soil Log Report, Gudveina Estates, Lot 1, Anchorage, Alaska Dear Mr. Marx: We are submitting herewith the test boring results and our comments re- garding soil conditions encountered at the subject site. This investigation was performed in accordance with your verbal instruction of May 23, 1972 and those procedures outlined in a letter dated September 13, 1971 by Mr. Rolf Strickland of the Greater Anchorage Area Borough Department of En- vironmental Quality. A single test hole was put down within the Lot 1 area for the purpose of defining general subsurface soil conditions. Excavation was accomplished with a tractor -mounted backhoe and the test hole was extended to a total depth of 11.5 feet. One sample was recovered from the bottom of the test hole and retained for grain size analysis. The final log prepared for the test hole has been included in Drawing A-01. The test hole is considered to represent the material lying within the lot boundaries. The soil profile disclosed by the -test hole indicated six inches of organic material with silt overlying a brown organic silt which extended to a depth of 2 feet below ground surface. At this depth, a gray silty sandy gravel (GM) was encountered and extended to a depth of 4.0 feet below ground surface. Below this depth, a gray sandy gravel (GW) was found and continued to the bottom of the hole. The soils were visually classified in accordance with the Unified Classified System. Ground water was not encountered in the test hole. ANCHORAGE FAIRBANKS JUNEAU May 24, 1972 Mr. Dick Marx Page 2 We appreciate being given this opportunity to be of service to you. Should you have any questions with regard to the above, please do not hesitate to contact us. Very trulyy@�rsv R & GiiT JWR:wb m jea•. No. 1316-E ._ •'tam% 15 OLOGICAL CONSULTANTS R&M ENGINEERING & GEOLOGICAL CONSULTANTS Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 pp Anchorage, AK 99519-6650 www.muni.org/onsitlonsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 017-161-08 COSA# C�5C L1��ZZn�/ 1. GENERAL INFORMATION Expiration Date: Complete legal description GUDVEINA LOT 1 Location (site address) 15540 BLAIR VIEW CIRCLE *ANCHORAGE, AK 99516 Individual On-site. Current Property owner(s) JACK BLAIR Day phone 257-0159 Mailing address Lending agency Mailing address . Real Estate Agent Mailing address 15540 BLAIR VIEW CIRCLE *ANCHORAGE, AK 99516 JOHN OHARA W/REMAX PROPERTIES Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 Day phone Day phone 223-4663 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual On-site. Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal andlor water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seat affixed hereto and as of the validation date shown below, t verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. f further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with a# applicable Municipal and State'codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE V Approved for ! bedrooms. Disapproved. 337-6179 Date _u .L fr Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other By: ( Original Certificate Date: (Rev. 11105) Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Elmore Road P.O. Boz 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: GUDVEINA LOT 1 Parcel ID: 017-161-08 A. WELL DATA *PER SURROUNDING WELL LOGS Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (YIN) Date completed 6/2/72 Sanitary seal (YIN) YES Total depth 156 ft. Cased to *40+ ft. FROM WELL LOG Date of test 6/2/72 Static water level 64 ft. Well production 12 gp. M. WATER SAMPLE RESULTS YES Wires properly protected (YIN) YES Casing height (above ground) 12+ in. AT INSPECTION 11/30/11 62 ft. 1.78 g.p.m. Coliform 0 colonies/100 ml. Nitrate ND mg./L. Collected by: GEG, Ltd. Arsenic: ND ug./L. Date of sample:l 1/23 & 29/11 B. SEPTIC/HOLDING TANK DATA *LOCATED IN EXTERIOR WALL IN BASEMENT LAUNDRY ROOM. Tank Type/Material STEP/STEEL Date installed 10/26-11/3/00 Tank size 1500 gal. Number of Compartments E Cleanouts (YIN) YES Foundation cleanout (YIN) *YES Depression over tank (YIN) NO High water alarm (YIN) YES Dateofpumping 'Z Z` N Pumper t� Doe S+or 0'11"``5 C. ABSORPTION FIELD DATA *BELOW EXISTING GRADE Date installed 10/26-11/3-00 Soil rating (g.p.d./ft2or /bdrm)12 System type TRENCH Length 54 ft. Width 5 ft. Gravel below pipe 4.06 ft. Total depth *8.08 ft. Eff. absorption area 540 ft2 Monitoring tube YES Depression over field NO Date of adequacy test 11130111 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 2 in. Water added 620 gal. New depth **2 in. Elapsed Time: E min. Final fluid depth 2 in. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) NONE KNOWN If yes, give date **620 GALLONS WAS INTRODUCED OVER 293 MINUTES AND WAS ABSORBED AS FAST AS IT WAS ADDED. D. LIFT STATION Date installed 10/26-11/3/00 Size in gallons 1500 Manhole/Access (YIN) YES "Pump on" level at 42" in. "Pump off" level at 42� in. High water alarm level at 46" in. Datum BOTTOM OF TANK Cycles tested 3 Meets alarm & circuit requirements? YES E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main Sewer /septic service line 25'+ Animal containment areas 50'+ Public sewer manholelcleanout N/A Holding tank Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption Feld 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that f have determined through field inspections and review of Municipal records that the above systems are in �' """""' ' """ "' " conformance with MOA COSA guidelines in effect on this date. Q:.......... •.J fr A.�prrn ss: Engineer's Printed Name JEFFREY A. GARNESS do o ` 9, E-795 I 0�4fA ' tZ/19rrlh �Ad4 Date /11 COSA �1��".°•P�,,.___;�no�oo COSA Fee $ Yb Date of Payment QL 14- 1 C Receipt Number ()C.N j G (Rev. 1iros) Waiver Fee $ Date of Payment Receipt Number Iw O h A h O' h, h'