HomeMy WebLinkAboutLot 01A
Tom Fink, 825 "L" Street
Mayor P.O. Box 196650 Anchorage, Alaska 99519-6650
January 8, 1990
Ken Wynne
9571 Noblewood
Anchorage, Alaska
99502
Subject: Lot lA Block 4 Campbell Lake Heights S/D #10
Permit #890024, PID #012-372-84
The subject permit, issued by this office for a single family
well and/or on-site wastewater system has expired.as of December
31, 1989.
Permits are issued on a calendar year basis by authority of the
Municipal Code of Regulations. A new permit must be obtained
from this office for an well and/or on-site wastewater system
not installed by the expiration date.
If you have drilled the well, a well log needs to be sent to
this office for documentation of the installation and to close
the permit.
If a private engineer inspected the installation of the on-site
wastewater system, the original as-built inspection report
(three-part form) must be sent to this office for review,
approval and documentation.
When applying for a new per,it, the f~es are: $90.00 for an
on-site wastewater permit; $50.00 for a well permit; $140.00 for
a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
Sincerely,
John Smith, P.E.
Program Manager
On-site Services
JW/ljm:200
enc: Copy of
Permit
"Kids Are Our 'Future"
M U N I C I P A L I ] ¥ 0 F A N C H 0 R A G E
Department of Health & Human Services
825 L Street, Anchorage, Alaska 99501 545-4720
Permit Number:
Date Issued:
0 N - S I T E W E L L
03/06/89
P E R M I T
Owner Name:
Owner Address:
KEN WYNNE
9571NOBLEWOOD
ANCHORAGE, AK
99502
Day Phone:
277-5522
Parcel Id: 012-57~-84
Lot Legal: Subdivision: CAMPBELL LK HGTS ~10 Lot:
Section: 14' Township: 12N Range: 4W
Lot Size lA Csq.~t. or acres)
'Max Bedrooms: lhis Permit: 0 Total Capacity: 4
lA Block: 4
WELL: Log must be submitted to Municipality o~ Anchorage Department of Health
and Human Services within 50 days of well completion.
OBSERVE ALL REQUIRED SETBACK DISTANCES FROM SOURCES OF
CONTAMINATION.
I CERTIFY THAT:
1. I am familiar
with the requirements ~or on-site sewers and wells as set
forth by the Municipality of Anchorage (MOA) and the State o; Alaska.
~. I will install the system in accordance with all MOA codes and regulations,
and in compliance with the design criteria o£ this permit.
5. I will adhere to all MOA and State of Alaska requirements for the set back
distances ~rem arty existing well, wastewater disposal system or rub'lie
sewerage system on this or any adjacent or nearby lot.
4. I understand that this permit is valid for a maximum of 0 bedrooms. I
also understand that.the capacity of the total system is 4 bedrooms and
any enlargement will require an additional permit.
Signed:
(Owner)
Issued By:
~-tO'
(907) 24~2282
KEN JOHNSON
KEN JOHNSON DRILLING CO.
WATER WELL DRILLING
PUMP SALES AND SERVICE
36 Years A/asks D~///ng
Dr. Ken Wynne D.M.D.
1080 West Pireweed Lane
Anchorage, Alaska 99503
3163 LINDEN DRIVE
ANCHORAGE. ALASKA 99502
AUGUST 4, 1989
EEl SOUTHOVER LAKE ~ ONE... LOT ONE BLK FOUR CAMPBELL LAKE
HEIGHTS SUBD. # TEN
WATER WELL LOG
0 ft to 5 ft
5 ft to 15 ft
15 ft to 9! ft
91 ft to 113 ft
113 ft to 120 ft
120 ft to 148 ft
148 ft to 156 ft
156 ft to 168 ft
168 ft to 170 ft
170 ft to 175 ft
175 ft to 177 lt-
l?? ft to 179 ft
179 ft to 194 ft
194 ft to 198 ft
198 ft to 230 ft
230 ft to 257 ft
257 ft to 261 ft
Compact Lt. brown silt with med. grav
Brown silt with clay texture
Clay ( bootlegger cove..greasy )
Clay with silty fine sand seams..weeps
Glacial ttll..Med, gray gray silt
Course gray and gray stlt..trace of clay
Same with finer grav
Wet dirty fine sand/ some clay seams
Clay and med gray
Course gray and gray silt..weeps in 20'..
Sand pumps dry. otight..
Glacial-till
Same..weeps
Glacial till .. dry
Clay with med gray
Blue clay...Swells., casing tight..
Same with med gray., casing refusal at 2)5 ft
100 blows per inch.. 230 ft ~o 235 ft
Drill open hole from 235 ft to 261 ft
Courser gray and gray silt..tight..clay seams
Material swells.. Due to the expense of reducing
and relining the hole with 5 in. casing and
the property is already on city water, we opted
to perforate six in. from 170 ft to 179 ft.
Casing was perforated with star.perforator and
surged and developed with negatxve results.
Total depth 261 ft. Total casing 236-3/4
DEPT. OF HEAL'~'I &
~,,,,IVI ROI,,L~ENTAL pRoT~CTIC~q
RECEIVED
KEN JOHNSON CWD/PI
NWWA CERTIFIED