Loading...
HomeMy WebLinkAboutCAMPBELL POINT BLK 1 LT 7 · .~1 ', Municipality of Anchorage Page . I of ..~ .--?" DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL'SERVICE5 DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Name Permit Number: ~ PID Numbel: C.A~.L,~HA~4, ~.11- WastewaterSystem: [~New n Upgrade ~. -/u~> - ¥~4e,'~9 %1~,~ ABSORPTION FIELD · ' : ~ Deep Trench ~ Shallow Trench ~ Bed O Mound ~ Other LEGAL DESCRIPTION so.....;: Tolal~ept h f rom ortg,na, gra.e~ WELL: D New ~ Upgrade O,~$~,mh: Ylela: ~ Pum~ Set at: J Cas,rig He,g.I A~ Ground' -- .. ~"" ;,. n. TANK SEPARATION DISTANCES ~s~;,c ~ .o~,~ e S.T.E.P. Well' II ~ l0 ~ >~S' Maleri,l: ~r ~NumberofCom~.meni,: Sudace Ware, ~ O H~ LIFT STATION Lot Line ~ ~ ID s,z~ ~. ~.,o.,, Cu~ain Dram ~ 0 ~ ~ Pump Make & M:~ el J Electnca~ Inspections performed by: Remarks: BENCH MARK ENGINEER'S SEAL Inspections performed by: Dates: ls~ Department of Heal,and ~u~a~Se~ices approval Rewewed and approved by: Date: ~ '~;.'- ;'-. ....... .. '"'.. ,~ ~ KERI COURT ~ vrd, ~r .Pcq¢. ;. :._ _ st~nc rA~ WOO ~ ~ / A I J I et ..~ ~ - _ I I RIO0. O0 £IMOND 25 §~ 75 SCALE: 1' = 50 F~ lDO 125 ~ 15o TOBBEN SPURKLAND P.E. 205 W 15TH. AVENUE ANCH. AK. 99501 PE£1dlT NO SV/970124 LOT 7, BLOCK I CAMPBELL POINT KIT CALL4NAN 7~01 W. D/MONO DL1/D. P. LN. 0II-252-21 SEPTIC SYSTEM AS BUILT DATE: JUN£2$, 1997 SHEET: 2/3 GRID: 2322 CP TOI O T£.D~G Stondord Trench 2' V;de 30' Long 12' Deep 7' Sewer rock 4.$' Cove,- 1000 go/ Sept;c ~ank NO SCALE ' I Iq/'~l~ IIII=~L 11 1000 SEPTIC TANK N~ SCALE £ENCH HA£1C SE coe. P£DESr~L ASSUMED ELEV. 10000 TDBBEN SPURKLAND P.L. 203 Wl5th Ave Anchorage A~ 99501 PERt. tIT ]/ $1Y.,qTO124 LOT 7, BLOCK 1 CAMPBELL POINT KIT CALLAHEN 700! ~. D1M£ND ~L VD. PID $ 011-262-21 SEPTIC SYSTEN AS BUILT DA?E, JUNE£~ 1997 SHEET, 3/3 GRID: B3~P CPTOIOT$.DV/C MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 PAGE 1 OF ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW970124 DESIGN ENGINEER:TOBBEN SPURKLAND, P.E. OWNER NAME:MARSON JAMES G & OWNER ADDRESS:7001 W DIMOND BLVD ANCHORAGE, ALASKA 99515 DATE ISSUED: 6/09/97 EXPIRATION DATE: 6/09/98 PARCEL ID:01126221 LEGAL DESCRIPTION: CAMPBELL POINT BLK 1 LT 7 LOT SIZE: 20400 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: ISSUED BY: 203 W 15th. Avenue, Suite 203 ANCHORAGE, ALASKA 9950 I (907) 279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN LOT 7 BLOCK I CAMPBELL POINT KIT CALLAHAN Municipality of Anchorage Department of Health and Social Services 820 1 Street Anchorage, Alaska 99501 May 14, 1997 We are submitting an application for the installation of a septic system for this lot. A well log for the existing well is on file with the tlealth Department. This submittal consists ofthree (3) drawings showing the present improvements on the lot and the adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only the septic system is subject to this permit application, (sheet 2/3), and a schematic ofthe septic system, (sheet 3/3). Soil fogs and percolation tests of applicable testholes are also enclosed. The septic system design is based on the following: No Ground Water or Impervious Layer to 18 fi. Use Standard Trench Soil Rating. 5 rain/in = 1.2 gal per sq.ft/day No. of Bedrooms 3 Required Area per Bedroom: 150/I.2 - 125 Total area required: 3 x 125 = 375 sq.fi. Proposed Finished Floor Elevation: 105 Ground Elevation at Trench: 105 +- Testhole depth 18 feet Bottom Rock At 12 feet Top Rock At 5 feet Rock Depth 7 feet Total Trench Length 375 / 2x7 - 26.8 fi. SYSTEM CONFIGURATION STANDARD TRENCH TOTAL LENGTti 30 FT TOTAL WIDTH 2 FT TOTAL DEPTtl 12 FT ROCK DEPTH 7 Fl' COVER 5 FT SEPTIC TANK 1000 GAL I~UNIcIPA, L~Fy OF ANC-J'iOgAGi: Eh[VIRoNRz~NTAL SERVICEs DIVIsIoN MAY 15 1997 RECEIVED The installation ofthis septic system will not prevent wells from being installed on the adjacent lots. ' ' There are no developed or na~ura[ surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentratioo of surface mnoffw[II not result from this installation, PERFORMED FOR, Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street. Anchorage. Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST 'EGA OESCRIPT,O.=_LoT 7, 1 2 3 4- '10 12 14- Township. Range. Section: SLOPE WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? SITE PLAN 15- 16- 17- 18- t=' Ho 20- PERCOLATION RATE ~ '7~'"(m,nL eum ~ t ' ch) PERC HOLE DIAMETER . ~__ ' :'" D~SCLA! TEST RUN eETWEEN -~.~ FT,~,',~ '~ ~ ~T * Past and presence and/or depth of groundwater can not be predicted ly.future · CERTIFy THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: __ ~'/~/~///~'~ 7 . 72qX)8 (Rev. 4/85) LOT ~ VACANT 5 \ / 6 1 7 ~rell $0 0 §0 lO0 150 ~00 ~§0 300 SCALE: 1' = lO0 FT. II I 5 KERI COURT 49~h TOBBEN SPURKLAND P.E. 203 W 15TH. AVENUE ANCH. AK. 99501 P£RYlT NO: XXX LOT 7, I~LOCK I C.~JIP£ELL POINT K#' ~4LL4HAN 7001 Fl. DIMONo OLVD. P, LN. XX SEPTIC SYSTEM DESIGN DATE: MAY I4, SHEET: 1/3' GRID: 2522 CpIOIOTI. DV6 105.4 *.***.*. SCALE: 1' = $0 FT. ~,/~ SEPTIC SYSTEM DESIGN ?£/~/r NO xxx P.I.N. XX CPTOZO78.~VG Sfanclard Trench 2' ~'~de 38' Long 12' Deep 7' Se~er rock 4.5' Cover 0 1000 9o! Septic lank NO SCALE NO SCALE lOOa SEPTIC TANK TOBBEN SPURKLAND P.E. 203 tdl5th Ave Anchorage Ak 99501 LOF 7, BLOCK 1 CAMPBELL KIT CALLAHEN 7001 I,/. D/HaND BL VD, POINT BENCH HARK. ASSUMED ELEV, 100.00 SEPTIC SYSTEM DESIGN DATE, HAY 14 1997 SHEET, 3/3 GR[D~ 2322 GREATER A~;CHORAGE ~REA BOROUGH Dep~'~tment of Environmental Quality~.-~ ...... i . 2330 "C" Street ~" " 'Anchorage, Alaska 99503 'Performe~ for M.~ & M,s~ Ri Moon~ Date performed ~£PT~10-11~1975 Legal Oescript'~on: ).? 9 RLnCK I ~ ~AM~LL POINT SUBOIVI$10N This form reports: Soils l~g. v ~ Percolation test x Depth Feet v,~,,,, ! ' 0v£NmuRorm: 1.5' 2- 3 4 -- SILTY SAN0$ (aSo) .o~.^sis or T, is~5' 7 ~PI:RC T£$Te 8- Was'ground w~Ler encountered? SP-S~ SOME S~NDS t FINE AND SOME SILT* SUT PERN£ABL£ I. / If yes, at what depth? Reading ~OUND :e, minute. : proposed installation: Seepage Pit ......... Drain Field'~ ..... Depth of Inlet ~mOUT ~' Depth to bottom of pit or t~ench 5-6, Performed By. t~. ~_ ~.~,~ .e~P~fled Bye/_ ~1 y~. Date: q-l~-~