HomeMy WebLinkAboutCAMPBELL POINT BLK 2 LT 8Campbell Point
Block 2
Lot 9
#011-262-06
~ MUNICIPALITY OF ANCHORAGE
~/~P'~ ' DEPA~tTMENT OF HEALTH 8* ENVIRONMENTAL PROTECTION
{~ ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NO. OF BEDROOMS
LOCATI~ . -- M~
~ Inside length Width Liqui~ep~n
NO. Of lines I Leng,
Length Width ~pth
< ~ Type of crib Crib diameter Crib depth
~[ Well Building f~ndation Near~t lot line
~ DISTANCE TO:
~ Class Depth Driller D~stance to lot line PERMIT NO.
~ Building foundation Sewer line Septic tank Absorption area(s)
~ DISTANCE TO:
OTHER
INSTALLER ~4~~
REMARKS
DATE LEGAL
72~t3 (Re~ 78)
PERMIT lqO.
r.lu I'-.I I C 3'"IR L I TY OF At~lCl
DEPARTMENT ,..r' HERLTH AND ENVIRONMENTAL r'ROTECTION
825 'L' STREET, RNCHORRGE-, AK. ~9501
2~,4-4720
14ELL Rt~O OI"-.I--S T TE SE[4ER
( 810854 )
3520 BRUCE LRNE 99502
pEP. l--1 I T_:~_l' q-35-~1
RPPLICRNT TERRY L. PRRSONS
LOCRTIOW DIMOND?CRRMER PLRCE
LEGRL L S B 2 CRMPBELL POINT SD LOT SIZE 1~500 SQURRE FEET
TYPE OF SOIL RBSORPTION S~STEM IS: TRENCH
MRXIMUM NUMBER OF BEDROOMS = 4 SOIL RRTING (~ FT/BR>=
THE REQUIRED qIZE OF THE ~OIL RB~ORPTIO"' S~TE" IS:
THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRIHFIELD.
THE DEPTH O~ R TRENCH OR PIT IS THE DISTRNCE BETHEEN THE SUR~RCE OF THE
GROUND RND THE BOTTO~I OF THE EXCRVRTION (IH FEET).
THERE I5 NO SET HIDTH FOR TRENCHES.
THE GRRVEL DEPTH IS THE MINIMUM DEPTH 0~ GRRVEL BETHEEN THE OUT~RLL PIPE
RND THE BOTTOM OF THE EXCRVRTION.<IN ~EET>.
REQLI I RED SEPT I C TRf~K S I ZE= ~25e
PERMIT RPPLZCRNT HR5 THE RESPOHS~EZL~TY TO ~NFO~ TH~5 DEPRRTMEHT DU~ZH~ THE
ZNSTRLLRTZON ZNSPECT~ON5 OF RMY HELL5 RD~ROENT TO THZ5 PROPERTY RND THE
NU~ER OF RE~DENCE5 T~RT THE HELL I,I~LL
TI40 ( 2 ;, ~ t~SPECT · 0~'~ RRE RE~LI ~ RED ------
BRCKF~LLZN~ OF RNY 5YSTE~ W~THOUT FZNRL ]HSFECT~OW RND RPPROVRL EY THZ5
DEPRRTMEHT H~LL EE 5UB~EC~ TO p~OSECLiT~ON,
M~NZ~UM D~STRNCE EETHEEN R HELL RND RNY ON-SZTE ~EI.IRGE DZSPO~RL SYSTEM Z5
~e~ FEET FOE R pRZVRTE HELL OR ~5~ TO 2~ FEET FROM R PUEL~C HELL DEPEN~ZNG
~PON THE TYPE OF PUBLIC HELL.
M~N~MUM DZSTRWCE FEO~ R ~VRTE HELL TO R F'~VRTE ~EWEE L~NE ~5 25 FEET
TO R CO~MIJN~TY 5EHER LZNE ~5 75 FEET,
HELL LO~ R~E RE~U~ED RMD ~U~T EE RETURNED TO THE DEPRETMENT H~THZN ~e
OF THE HELL COMPLETZON.
OTHER REQUTRE~ENT~ ~R~ RPPLY, 5pEC~F~CRT~ON5 RND CON~T~UCTZON O~R~RRr'~ RRE
RVR~LRELE TO ~N~U~E FROPER ZNSTRLLRTZON.
PERf~ I T EXP I RE5 DECEt~BER ~l-
I CERTIFY THRT
l: I RM FRMILIRR WITH THE RE~.UIREMENTS FOR ON-SITE SEHERS RND HELLS RS SET
FORTH BY THE MUNICIPBLITY OF RNCHORRGE.
2: I HILL INSTRLL THE 5YSTE~I IH RCCORDRNCE WITH THE CODES.
3: I UNDERSTRMD THRT THE ON-SITE SEHER SYSTEM MRY REQUIRE ENLRRGEMENT IF THE
RESIDENCE IS REMODELED TO INCLUDE MORE THRN 4 BEDROOMS.
S I GNED: ................
APPLICRf,IT TERRY L. PARSONS
ISSUED B~'_ ............................. DRTE
V4. 0
,_ , ~.,~I,.UNICIPALIT~ OF ANCHORAGE~'~
Department f Health eno Hnvironmenta Protection
~ 825 L Street, Anchorage, AK. 99501
- 264-4720
* * * HANDWRITTEN PERMIT * * *
WELL AND~I~ ON-SITE SEWER PERMIT
Type of Soil Absorption System Is:
Trench: ~ Drainfield: _ Seepage Bed: Holding Tank: .
Maximum Number of Bedrooms: ~/ soil Rating(sq.ft/br)
The Required Size of the Soil Absorption System Is:
DEPTH _ /~ LENGTH ~ 5 GRAVEL DEPTH 7' WIDTH
The length dimension is the length(in feet) of the trench or drainfield. The
depth of a trench or pit is the distance between the surface of the ground and
the bottom of the excavation(in feet). There is no set width for trenches.
The gravel depth is the minimum depth of gravel between the outfall Pipe and
the bottom of the excavation(in feet).
· * REQUIRED SEPTIC(HOLDING) TANK SIZE = /'2"~"4::2GALLONS * *
Permit applicant has the responsibility to inform this department during the
installation inspections of any wells adjacent to this property and the number
of residences that the well will serve.
· * * TWO(2) INSPECTIONS ARE REQUIRED * * *
Backfilling of any system without final ~nspect~on and approval by this departmen
will be subject to prosecution.
Minimum distance between a well and any on-site sewage disposal system is 100 fee
for a private well or 150 to 200 feet from a public well depending upon the type
of public well. Minimum distance from a private well to a private sewer line
is 25 feet and to a community sewer line is 75 feet. Well logs are required
and must be returned to this department within 30 days of the well completion.
Other requirements may apply. Specifications and construction diagrams are
available to insure proper installation.
· * * PERMIT EXPIRES DECEMBER 31, 1 9 8 1 * * *
I certify that: .
(1) I am familiar with the requirements for on-site sewers and wells as
set forth by the Municipality of Anchorage.
(2) I will install the system'in accordance with codes.
(3) I understand that the on-site sewer system may require enlargement if
the residenc~ i~emodeled to include more that ) bedrooms~
Ap~ licit ~
SWP/024 (1/81) ~~
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAl- PROTECTION
825 L. Street, Anchorage, Alaska 99501 264-4720
SOILS LOG -- PERCOLATION TEST'
~SOI LS LOG
PERCOLATION
TEST
PERFORMED FOR:
LEGAL DESCRIPTION:
3
SLOPE
SITE PLAN
11
12
13
14
15-
17
18
19.
20-~
Oa~lh O. Tc~,ot
WAS GROUND WATER ~O SL
ENCOUNTERED? O
P
IF YES, AT WHAT ~- E
DEPTH?
Gross Net Depth to Net
Reading Date Time Time Water Drop
~ (minutes/inch}
:O LATIO N RATE
EST RUN BETWEEN .
COMMENTS
PERFORMED
CERTIFIED BY: ~~, ~T E:~
724)08 (6/79)
WATER WELLS
665 ~'. 1~7lh Avenue
Anchorage, Alaska 99502
lell location: (addr~s~le~al desc,lption) ,
Depth Of well ~/~' ft. Casing: dapth~ ~/~ ft.
lell yi?d tested by (p~mpifl~. bailing, air) at
WELL CONSTRUCTION LOG
.. USGS ne.
cot, ,,l~ co,pl,,,d~c~"~''''' ' .~7- /~ ~' !--
_.
Type of ~eafest community · ~ ~
Location sketch ar remarks
.ual/min.
,.hours with.__.~L~.,--ft* of drawdown from static level.
DRILLER'S MATERIAL LUG
Oepth bela. land
surlace in leer
Dive description of strata penetrated ,
-(size of material, color, hardness of drilling, end water content)
.to
tO
tO
~te o, ta \ / Pete
Inspector Inepector / ~ Inspector
~mments ~n~ltlonal Approval
~l~s Rating Well To Absorption Area ~ ~1L R
~ ~ ~ Well to Tank
APPLICANT FILLS OUT LOWER HALF ONLY
Prope.y~ner /~r/ X, ~r~: Phone
Buyer
Address , ~'
Reaity ~. & Agent ~ Phone
Address
Type~ Residence
~Single Family
~ Multiple Family No. of Bedr~ms
~ ~her
Wat~upply
~ndivldual A~ACH WELL LOG. A well log Is requlr~ for all wells driil~ since June
~ ~mmunlty 1975. For wells drilled prior to that date, give well depth (attach log If
~ Public Utility available.}
Sew~ DIs~sat
~ Individual Year Individual Installed:
~ Public Utility When ~nnected to Public Utility:
~ Holding Tank
NOT~ THE INSPECTION FEE MUST ACCOMPANY ~CH REQUEST BEFORE PROCESSING CAN BE INITIATED.
January 27, 1982
Terry L. Parsons
3520 Bruce Lane
Anchorage, AK 99503
Subjects Lot 8, Block 2, Campbell Pt. S/D
Dear Mr. Parsons~
Approval for the individual sewer and water facilities cannot
be granted until thc following items have been completed~
· Exposed electrical wires to the well head are in violation
of the Municipality of Anchorage codes and must be encased
in conduit.
· The water analysis report needs to be submitted to this ,
office from the Chem Lab, 5633 B Street, for our.review.
Please notify this department for a reinspection when the
noted discrepancies have been corrected. If there are any
further questions, please call this office at 264-4720.
Sincerely,
Robert C. Pratt
Associate Environmental Specialist
CHEMICAL & G~''~-OGICAL LABORATORIES ?h ALASKA, INC: ~
274-3364 . 5633 B Street ~o
Drinking water Analysis Report for Total coliform Bacteria
TO BE COMPLETED BY WATER SUPPLIER '
WATER SYSTEM:
Water Syltem Name
Mailing
I.D. NO.
Phone No.
city
MO. Day year
Zip Code
SAMPLE TYPE:
n Routine
r-I Check ~.e (for routine ~lmple
with lab no. )
0 Special Purpose ..
[] Treated Water
[] Untreated Water
SAMPLE
NO.
2
4
LOCATION
Time Collected
Coile~te~ By
lO:J,: ~_F)
TO BE COMPLETED BY LABORATORY
Analysis shows this Water SAMPLE to be:
.,~:::~Satisfactory
[-I Unsatisfactory
[] Sample tOO long in transit; sample should
pot be over 48 hours old at examination
to indicate reliable results. Please send
new sample.
Date Received ,,/ ".~i. ," . , '
Time Received / ~/" ' '
Analytical Method:
ID Fermentation Tube
'O.Membrane Filter
Lab Ref. No. Result* Analyst
I ICI
I F'T-1
I
0~-1220
READ INSTRUCTIONS 'r
BEFORE.
COLLECTING SAMPLE
BACTERIOLOGICALWATER ANALYSIS RECORD
19 February 1~56
Ca.~phell Point Cubdivisic~
final Plat.
The o~c~ pla~'h~s been ~v~ewed My ~he Borough Jteal~h ~pa~me~. Our
1. la a comm~l~M ~er sys~e~ c~tozplated?
2. Xs zew~c d~pcsal ~o be via ~ zite ~thods or collecto~ou~-
f~l se~er~
3. l~ on 8X~ se~a~e d~sposal ~s ~o ~ ~ed, a~ so~l c~dX~l~s
adequate? This sh~ld ~e dote~lned thigh percolation ~estS
perfO~e~ by a ~glste~d professl~l en~ineer.
Sinca~ly,
DAVID R. L. Db'~.ICAtl, ~.D.
P, edical Director
~lifford ¥. Judkins
~uperVisin~ Sanitarian
Municipality of Anchorag
o� `�
PA. IL,r 11XXM • Attchnrul!c, Alaska rJlI, M66N) • Telephone (!X)7) 3tA &'S01 •Par (1X17) A43 ft'.IM1 s • , r .
47M Itralmw• Strecl • Anchom9c. Alusktt!X6507
p�t�r.munl.nq;
31agor 3/ark Bcgich Iluilding Safety Di%islon
6/6/2005
Gamess Engineering Group
3701 East Tudor Road, Suite 101
Anchorage, Alaska 99507
Subject: Waiver Request for Campbell Point Subdivision, Block 2, Lot 9
Waiver Request #WR050036
Parcel ID #011-262-06
Permit # SW040499
Dear Mr. Gayness:
Your request for a waiver of the required 100 feet horizontal separation from the
septic tank on Campbell Point Subdivision, Block 2, Lot 8 (Lot 8) to the private well on
Campbell Point Subdivision, Block 2, Lot 9 (Lot 9) has been approved. The approved
separation distance is 88.0 feet. In addition, your request for a waiver of the required 100
feet horizontal separation from the absorption field on Lot 8 to the private well on Lot 9
has been approved. The approved separation distance is 95.0 feet.
This waiver approval applies to the existing septic tank and absorption on s to wastewater
8 to
private well on Lot 9 separation only. Any future upgrade
disposal system on Lot 8 or private well on Lot 9 will require all separation distances be
met or another approval from this department.
If there are any further concerns or questions regarding this waiver, please call our office
at 343-7904.
Sincerely,
julie Makela, P.E.
Civil Engineer
On -Site Water & Wastewater Program
Conununiiy, Security, Prosperity