Loading...
HomeMy WebLinkAboutCAMPBELL POINT BLK 3 TR 1T.SPURKLAND P.E. 203 W. 15th. AVE. SUITE 203 ANCHORAGE, ALASKA 99501 (907) 27%3916 Fax (907)-276-6013 Municipality of Anchorage Division of Environmental Health Department of Health and Social Services 820 i Street Anchorage, Alaska 99501 Septic System Installation Tract I Block 3 Campbell Point PID # 011-262-02 RECEIV.ED APR 1 8 1995 D Munimpal~ly of Anchorage ept. Health & Human April 17, 1995 Gentlemen; On April 17, 1995 I exposed the comers of the septic tank in serving this property. I found that the septic tank was made of concrete with an outside length of 9 feet and width of 4 feet. The water depth in the tank was 58 inches. Based on these measurements I concluded that the tank ia a 1000 gal tank. Yours Tobbe MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Servlc6§ Section P,O, Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D. # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING GENERAL INFORMATION Complete legal description ** Location (site address or directions) A,~ Prope~yowner ~' ~VEY Mailing address ~ ~~/ Lending agency ~~/~ ~ Day phone Mailing address ,~//~ //~//~ Agent ~ ~{~ C~ Day phon~ Address ~/ /lC ~/~, Unless othe~ise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: ~ TYPE OF WATER SUPPLY: Individual well Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest- . lng to the legality and status of system. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, p~ovide written confirmation from State ADEC attesting to the legality and status of system. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as o~ the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Mur~icipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm ,~)//-/// ~'~L~/4//(-5'"~-']~'~'//V/~ ~'/"/~:'~" Phone ,"~'~'-~'--/'--~"-~' 0, Add~eSSEng,neefss,gnature-. %~ ~ Date DHHS SIGNATURE /~, Approved for '~ F~'), Disapproved, Conditional approval for bedrooms. bedrooms, with the following stipulations: Additional Comments The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given In paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is Issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Municipality of Anchorage Department of Health and Human Services HEALTH AU'i'HORI'i'Y APPROVAL CHECKLIST Legal Description: A. Well Data Well type '~.J~ I! A, B, or C, attach ADEC letter. ADEC water system number Log present (Y/N) /~ ~ Date completed >//G~.--~' Driller Sanita~ seal (Y~) ~ Wires propeay~aed (Y/N) FROM WELl. LOG AT INSPEC~ON Date of test Static water level Well flow g.p.m. Pump level1 SEPARATION DISTANCES FROM WELL TO: Septic/holding tank on lot 7~.~ ~' 7- (~) Absorptlon field on lot ' {~ Public sewer main Sewer servlce line /V,,~l ; On adjacent lots ; On adjacent lots ~ 15'0,c7' ED Public sewer manhole/cleanout Petroleum lank /VA WATER SAMPLE RESULTS: co,,orm mn Date of sample: .~./~/~2-~ ' B. SEPTIC/HOLDING TANK DATA Date Insta,e / qb '£ Cleanouts (Y/N) Y High water alarm (Y/N) ,. .' Date of pumplng ' Pumper SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Nitrate {~, :~-~:~)I~/~--- Other bacteria Collected by: Fou~ation cleanout (WN) ~ Depression (YIN) Alarm tested (YIN) Well(s) on lot ~/? ~' (~) On adjacent lots To property line .~.~---/--/:: 7' ~ Absorption field Sudace water/drainage /~O/k[~-----'' >IS~F-/' ~7~ Foundation 72-026 (3/93)° Fret CONTINUED ON BACK PAGE Date Installed Size In gallons Vent (Y/N) High water aJarm level Meets MOA electrical codes (Y/N), 'Pump on" level at .Manufacturer Manhole/Access (Y/N) 'Pump off" Level at Cycles tested SEPARATION DISTANCE FROM LIFT STATION TO: Well on lot On adjacent lots Surface water /,...! D, ABSORPTION FIELD DATA~ '" ~"~ ~'~'-/ .,.~. CT.~ ~'~..2~ ,~' ~..,~t, t ~- ~' ~"~ ~'~----. Soil rating'(GPD/FF) /'//~'/~ System type Total absorption area ~-..~'/~',~" .Cleanout present (Y/N) y Depression over field (Y/N) · Date of adequacy test .~/~2,/~,.~ Results (pass/fail) p~,.~ fOr ~ .Bedrooms : Water levei In absorp~icn field before test ("~// I~) Alter test (~// · Peroxide treatment (past 12 months) (Y/N) /~ If yes, give date Well on lot ,,~O~'~'7" ~ On adjacent lots _/~ /,'~"(~)~'7' {~) Property line (~ '~'7- To building foundation / 7 ,'~'7" ' (T,) To existing or abandoned system on lot ,/~/,,~ On adjacent lots /,~//,z~ Cutbank '/,"~---"/"~ (~ Water main/service line /"V/~ Surface water ,/~//~)/v/~ Driveway, parking/vehicle storage area / ~/::7" E. ENGINEER'S CERTIFICATION I cerEfy that I ha~ checked, vedEed, or conformed to allMOA and HAA guidelines in effect on the date of this in~pecEon. Signature _ t Engineer's Name HAA Fee $ ' Date of Payment Receipt Number 72-0~ (~31' ~ Waiver Fee $ Date of Payment Receipt Number yx lannlng Cxv~l September 23, 1993 W.O. 93083 Municipality of Anchorage Dept. of Health & Human Services On-Site Services P.O. Box 196650 Anchorage, Alaska 99519-6650 RE: Health Authority Approval Tract I Block 3 Campbell Point Subdivision Dear Sirs: Our firm conducted a Health Authority Approval for the above indicated lot on September 18, 1993. This test was a retest of a health approval conducted by our firm, on September 14, 1993, which did not pass. Due to the age of this system, no information is on file with the Department of Health & Human Services. During our discussion with the owner, Mr. Harvey Barnhill, he indicated that the system was in stalled prior to 1968, at approximately the same time as the system on Lot 1, Tract B, Barnhill Subdivision. Please see attached sketch for a description of the system. Our as-built, performed at the same time the Health Authority Approval was conducted, shows that the well is approximately 73 feet away from the septic tank. While this separation distance is less than the presently required 100 feet, the age of this system allows the well to be not less than 50 feet from the septic system. Our septic adequacy test applied water to the system at a rate of 6.5 GPM, the system accumulated 22 inches of water, which had completely drained by the end of the 24 hour test period. PO Box 111349 Anchorage, Alaska 99511-1349 · (907) 345-1385/Fax 345-1386 In consideration that this system accepted the required surge volume of water, and that it appears to be in compliance with all regulations in force at the time of its installation, we request the system be approved for 2 bedrooms. Should you have any questions, please feel free to contact us. Sincerely, DHI Consulting Engineers. Robert W. Wright, P.E. Project Engineer cc: Dee High, DHI Gail High, DHI ~ W. D//~tOND BLVD. (KtNCAID ~ ~~ ~ ROAD) ~ DHI CONSULTING gNGINBEgS n~u.[ ~ CWL · su.v~.o · ~a,~,o TRACT NO.1. BLOCK 3 ~.,.~o..: (,o~)~,-~,~ ~..: (.o.)~.~-~.~ CAMPBELL PT. SUBIVISION ""~''""~'"'"'~"~ ~"-'~ SEPTIC SYST. SKETCH ~9/22/9~ 15:~9 CT~E ENUIR[I'~I'~gl- LAB ~]~UICES - 907 545 1~86 H0.959 COMMERCiA/TESTINQ & ENGINEERING CO. E~I¥1RONMENTAL LABORATORY !~ of Checcl~h Ref.t 193.4912-1 Client ~Ple ID zT~ACT I ~ P~ E~--~- See Special Instruction= ~bove Zee ~le R~ ~cte~, R~ vol~ is ~e pra~ic~ ~ttfl~tl~ limit. LT Se~ dllut t~. ENVIRO~Id~TAL ~RV~C~S IH ALA~(~ COLO~IADO, UTAH. ILUHO~5, OViO. MARYLAND, ~/EST"~IRG~[LA. NEW jr.~¥ ~OUTM CAJROLtk~A Mr Harvey Burnhill Kinkaid Rd. Anchorage, Alaska JOHHSOH DRILLIHG .. :3163 LINDEN DRIVE ANCHORAGE, ALASKA - II'lONg 844-.~,%5 August 28, 1967 Drilling ~nd casing Six inch well at $ I0400 per ft. 267 ft. ..... .......... ........... $ 2670'j00 .1 six inch drive shoe 15.00 1 ! bp. peerless 4plb102 submersible pump with box 310.00 252 ft. 1" galv. pipe 126.O0 340 # 12 60Ov Sub~ pump cable 102.0D 1 pitless adapter 38.'50 1 accessory package 22.50 I well seal 10.00 60 ft. 3/4" L copper soft 39.00 1 l& 4 galv. nip. .75 1 1" galv cap .40 ! I" & 3/4" bush .60 ! 3/4" flare adapter 2.00 Installing pitless adapter and perm pump..Lump sum 65.00 Less y% for cash Paid on account $ 3401 .?.~ 17o.05 $ 3235.?0 1000.00 CO~ SO. O0 ~J · w.O 05083 I, R;chord P. Hank;ne. hereby certify that I hove su~eyed"~'; the property described hereon and that no encroachments exist except' as indicated hereon. ex,st- It is the responsrbtJb/ of the owner to de. te.r~..me the . ence of any easements, covenants, or re~Trlcuons not appear on the recorded subd/v;sion prat. cumstonces should'or~y data hereon be used for · or far eatob/ishinq bOUndcry or fence'llne$. · .... . · ~..;~ '~r ~.!;;~,... · ...,.-...~. ~ ,,~: , " ' j~ ,'.~ .C., AS-BUILT TRACT NO.1, CAMPBELL PT. BLOCK :i 3 " SUBIVISION , S V'b ',,,~ ~,~, o... ~1~ COURT ' " .... ~: ...j '. KERI: ' ~ " · . ,..-,. ..:.,. ~ '..: · . .~ ....:~.;~'..'~ -: ,~. ,e~/n'~, ,.....,. :.-'... .. .. C~v~l rvey~ nih October 21, 1993 W.O. 93083 Ms. Susan Oswalt Municipality of Anchorage Department of Health & Human Services Environmental Services Division P.O. Box 196650 Anchorage, Alaska 99519-6650 eeot,Ue$ ue,,,nH ,~ qlleeH e§eJot/ouv Jo RE: Health Approval / Tract 1 Campbell Point Subdivision Dear Ms. Oswalt, In accordance with our previous telephone conversation, we have conducted a soils investigation for the on-site septic system on the above indicated lot. Our investigation was conducted on 10/13/93 by Mr. Bob Wright, a registered Civil Engineer with our office. The investigation consisted of boring a single 16.5 foot hole near the existing septic system. ACME 75 drill rig was utilized, using 7" diameter rite augers. Attached with this letter report is a log of the boring, and an updated as-built drawing (Figure 2) showing the location of the test boring in relationship to the existing septic system. The auger flites were continuously monitored over the full depth of the hole. Out findings are illustrated in the attached log (Figure 1). A 1' PVC monitoring tube was installed to monitor any groundwater which may exist, bio groundwater was detected while drilling. The soils appears to be a well graded sand with gravel. Estimated absorption rate by visual classification is between 85 and 125 square feet per bedroom. PO Box 111349 Anchorage, Alaska 99511-1349 · (907) 345-1385/Fax 345-1386 Page: 2 Health Approval Tract 1 Campbell Point Subdivision On October 20, 1993, we inspected the water monitoring tube, and found no water in the hole. While on site we inspected the well cap and seal. We noted that the pump wires were sealed at the point they enter the well cap. Sincerely, DHI Consulting Engineers Robert W. Wright, P.E. Project Engineer CC: Dee High, DHI Gall High, DHI Mr. Harvey Bamhill 0-1 FT. BLACK ORGANIC SOIL AND ROOT MAT, MOIST. 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 1-6.5 8.0 9.0 10.0 11.0 12.0 15.0 14.0 15.0 16.0 -- BROWN, DRY, SANDY LOAM, POORLY GRADED. 6.5-16.5 BROWN TO GRAY, DRY TO MOIST, SAND WITH GRAVEL. CLEAN, NFS, BECOMING COARSER WITH DEPTH. RECEIVED OCT 2 1 1995 Mumclpahly Gl AnChorage Dept. Health & Human Services 16.5 END HOLE. NO WATER WHILE DRILLING, 1" MONITOR TUBE INSTALLED. SEE ATTACHED AS-BUILT FOR SWING-TIE LOCATION OF HOLE. BORING DRILLING MONITORED AND LOGGED ON 10/15/93 BY BOB WRIGHT ENGINEERS · PLANNING oDtlI CONSULTING CML · SUEVEY~G Telephone: (907)345-13§5 FIGURE 1 TR. 1 CAMPBELL PT. SUB. LOG OF SOIL BORING HOUSE 0 SEPTIC SYSTEM RECEIVED OOT 2 1 199:~ J¥;U.l.C,palily DJ Anchorage Oept. Health & Human Services BORING LOCATION DETAIL SCALE: 1"= 20' W. DIMOND BLVD. (Kt~CAtD ~O^D) oDHI CONSULTING ENGINEERS CML · SURVEYING · PLANNING Telephone: (907)345-1385 Yaz: (gO7)345-130~ FIGURE 2 TRACT NO.1, BLOCK CAMPBELL PT. SUBIVISION