Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutGREENLAND BLK 7 LT 11nland
Block 7
Lot 11
#015-171-14
--'-1
I 4 pre ~ uu.uu
~ monitor tube
4'pya
1 ©
manhole 4'pvc drolnfield \
oCOVer C.O. · trench\
· 4"pvc
C.O.
Alley
1
7
12
!
Frame Hse I
orientation and I
s(fale are approx.I
RIO0.O
1 1/2 story
Frame Hse
50.0
6" Well
casing 1'6"
· abv grnd
100.O0
1 "=40'
· 4"pvc C.O.
· 6" domestic
water well
WW line location
determined fram
East 1 13th Avenue
4" pvc C.O.
NOTES
1. Hse location and dlmensions 'Ore record information from a
'Bi(6
I
I
I
I
1992 As-built Survey by
Dowllng and Associates,
2. The Iocatloh of the septic tank - dralnfleld cleanouts and wells was estobllshed using
swing ties wlth o 100' cloth tape on 11/11/98.
5. Septic tank and drolnfield cleonouts ore above ground. Monitoring tubes and terminal
drolnfield cleanduts ore buried within plywood end 2x4 lumber frame box with metal. All
were readily located and accessable. All pipes were capped with "jlm caps.".
4. Site work was done on 11/11/98.
Lot !1 Bk 7 $onitoUon II ~ I1~'''"'11
Greenland SubdlvlslonlllmprOvernent $1tell~tll ~ II
plot P-268 Plan for
District Approvo ~1 ~ I
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519--6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: ..~'~/~,~2..~ Z~:~ PID Number:
N,mo:,,IZ~'~.e,.?' J~,~,o~ !wastewaterSystem: BNew
Ad~re~:
~7~/ ~ //3,~ . R.v~. ABSORPTION FIELD
LEGAL DESCRIPTION ~'~'~: :,.~
GPD~. FI.
Lot;// ~.7 ~~Subdiws~ on* ~ ~ ~ ~lr~ ~ g~:
WELL: ~1 5~'i~ ~ ~"~"~0~:" ~
rRiv~
Ft.
Yield: J Pump ~1 al: · ' ~ ~hlA~ G~:
SEPARATION DISTANCES ~p,= ~ Holding
TO ~ptrc ~ Ab~rpti~ Lifl H~di~ Pu~,vlle ~uf~l~r: ~i~ in gallonl~
Surface
Drain
Remarks: ~, ~ ~~. BENCH ~ARK
L~li~ an~ ~riplion:
Inspections pedormed by: :. _ Dates: 1st_ -- --,.--~,lr..
a~ ~ Human Se~ices approval "'"~ mo*~ 43a].~ .o~.,oo ~
Department of He an
Reviewed and approved by: ' Bate:
(R~,g/91J
Permit No. ~'vJ cJ'Z- 05 Z..~' Page ~' .of '-~
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Legal Description: ~--"¢~/], ~)l,o~r... '7~ ~---Wt~'l~'~t../~rJ~ PID No.: 01~/7/1~
~EAL
72-013 A (2/91)MOA 25
Permit No. ~' L~ ~ Z.O ~ ;1. ~ Page
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Legal Description: ~::~'/" //~ ~'~,06/.¢... ~ ~__~/24;~h/ ~..-4~J~ PID No.: ~15"'/7 /I~/
ENGINEER'S SEAL
72-013 A (Rev 9/91) MOA 25
RECEIVED
SEP 2 199~
WATER WELL RECORD
STATE OF ALASKA
DEPARTMENT OF NATURAL RESOURES
Division of Geologicol 8~ Geophysical Surveys
IViumcipality of Anchorage
Oept. Health&HumanService~rm~.~ Per.m No.
LOCATION OF WELL (Pleole complele ettber la, lb or lc.) A.D.L. No.
~"o,a..h S.bd'.'.'o. LO, G,o.. '~.1 '/.q'r.. S.e,,o. No. 'o...h'PNO .on. .m
g. WECL LO0 Peel Oelo~
Surface 4. WELL DEPTH: (tin*l) 5. CATE OF COMPLETION
~.~ / /~'~d ~dt ~, ~Auger ~dotted ~8ored ~Other:
/ / ,
8. CASING: ~ Threaded ~ WeldJd
Sol between ft. and ft.
Back filling ~ravel pack
' Equipment used:
I
ii. PUMPING LEVEL belo~ land *urfoce end ~IELD
.~e~ ~ ( j~~ I8.G"OUTINO Well Grouted: ~ Ye, ~ No
' d j - ' ' I~, PUMP: (If available) HP
14. REMARKS:
16. WATER WELL CONTRACTOR'S CERTIFICATION'.
15, Water Temperature ~o ~ F ~ C
Thl~ well was drilled under my jurlsd[cllon and this report is true to the best of my knowledge and belief;
' -RegiStered ~us~n~ss Nom~ ' ~ Contract License Number
- - ' ~uthorlz~ ReprelentolJve
Form O~-WWE (H/81) Copy Distribution: WHITE-State OGGS, PINK-Driller, CANARY-Customer
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT
]PERMIT NUMBER:SW920326
DESIGN ENGINEER:ANDERSON ENGINEERING
OWNER NAME:BROWN ROBERT A &
OWNER ADDRESS:4721 E ll3TH AV
ANCHORAGE, AK 99516
DATE ISSUED:10/01/92
EXPIRATION DATE:10/01/93
PARCEL ID: 01517114
LEGAL DESCRIPTION: GREENLAND BLK 7 LT 11
LOT SIZE: 17325 (SQ. FT.)
NUMBER OF BEDROOMS: 4 THIS PERMIT: 4
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAACS0).
3. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
THE EXISTING PIT MUST BE PROPERLY ABANDONED. THE UPGRADE
SYSTEM MUST BE INSTALLED AS SHOWN ON THE APPROVED ENGINEER'S
DESIGN DATED 9/8/92.
ANDERSON ENGINEERING
P,O. Box 240773
Anchorage, Alaska 99524
September 16, 1992
Municipality of Anchorage
Department of Health & Human Services
P.O. Box 196650
Anchorage, Alaska 99519-6650
Attention: John Smith, P.E.
Reference' Lot 111 Block 7, Greenland Subdivision
Subject' System Design Submittal Documents
Dear Mr. Smith:
None of the information submitted to date on Lot 11, Block 7, Greenland Subdivision
was either false or submitted with the intention to willfully and purposefully mislead
you or your office. Several of the allegations made in your letter of September 15, are
without basis and patently untrue.
Many hours were spent on Lot 11, Block 7, Greenland Subdivision to determine the
adequacy of the onsite crib system. The results of these tests were summarized to you
in letter form on September 11, 1992. All of this information was true and accurate and
certainly not fabricated as alleged in your letter. In addition, the percolation tests were
completed using hand auguring equipment well before the rnachine test holes were
excavated. These tests were completed in accordance with acceptable design
standards. Again, I take exception to your allegation that the percolation testing
information was fabricated.
I reviewed all information concerning the onsite systems on Lot 11, Block 7, Greenland
Subdivision before any work was completed on the lot. The boring Icg completed by R
& M consultants and utilized to design the existing crib system was thoroughly
reviewed to determine water table and soil type on the lot. Similarly, a previous
adequacy test was analyzed to determine the volume and operational characteristics
of the system. Municipal b.s builts of both the well and septic system were carefully
studied prior to any design work being accomplished In short, I was very familiar with
both the soil type and water table on this lot before any system evaluation or design
began.
The water in the absorption crib was monitored for nearly two weeks prior to submittal
of the system design. This information as well as tile assertion on the R & M soils Icg
made me confident no ground water existed on the lot which would interfere with the
new septic system to be placed on the lot,
The soils logs submitted with fl'~e design indicated the groundwater had been
monitored for 7 days. This, in effect, was true since the water in the septic crib had
been monitored for at least 10 days. The groundwater at the particular locations
Municipality of Anchorage
Department of Health & Human Services
September 16, 1992
Page Two
identified on the design, however, had not been monitored the full 7 days. I felt this
would not be a problem as the time frame from design submittal to permit issue would
easily exceed the 7 day period and monitoring could take place during this time. I was
also concerned with the onset of winter and the completion of the system before the
first snowfall. Unfortunately, I did not mention this assumption in the design
documents. I apologize for this oversight if it caused any problems to you or your staff.
I do feel, however, that it had no effect on the integrity of the system design. The test
holes were dug to a depth approximating 15'. The excavator, however, only had two
lengths of monitor tube, each 10' long. The testholes required a minor amount of
backfilling prior to placement of the tubes. The tubes now extend to a depth between 9'
and 10'. Since the bottom of the system is designed at 6-1/2' below ground the water
table must be lower than 10-1/2'. The tubes will be adjusted to this depth to verify this
situation. Since I am the individual charged with certifying the operability of the
system and any downstream liability falls on my shoulders, I feel I am the best judge of
the amount of design data necessary to complete the system.
All personnel working under my certification will review their practices and procedures
concerning the design, construction and operation of onsite water and wastewater
systems. Any assumptions made will be carefully documented on the design
information. No work ever completed in the past was submitted to your office with the
intent to mislead you or your staff. We will make every effort in the future to maintain
high quality standards.
Sincerely,
Michael E. Anderson, P.E.
xc:
Helen Beirne, Ph.D., Director, Health and Human Services
Lee Browning, P.E., Manager, Environmental Services
September 9, 1992
Municipality of Anchorage
Dept. of Health & Human Services
Environmental Services Division
825 "L" Street, Room 502
Anchorage, Alaska 99501
Subject:
Lot 11, Block 7, Greenland Subdivision
Septic System Design
hnpacts to Adjacent Properties
Deal' On Site Services Engineer:
The absorption crib on the subject property has failed and we are
proposing to replace it witln a shallow, wide trench system. The existing
tank was placed recently and slnould be acceptable for continued service.
We will verify its integrity during construction of the system. The
property is virtually flat with no surface water evident. Lots iii this area
are small and wells fl'om adjacent prol)el'ties limit the usable area for a
septic system. I have visited the property and inspected nearby properties
and have arrived at tile following conclusions:
Tile system, if constructed as designed, will have no adverse
impacts on the wells currently in use or to be placed in the future
on lots located in tile area.
The system, if constructed as designed, will have no adverse
in]pact on existing septic systems in the area or those to be
constructed in the future.
The system, if constracted as designed, will have 1]o adverse
impact on reserved space either surface or subsurface on any lots
located ill tine area.
'File system, il' co]smutted tls designed, will In]ye no adverse
impact on drainage paltel'lqS ill tile area.
Sincerely,
Michael E. Anderson, P.E.
ROCKFORD CORPORATION
P.O. Box 111706
ANCHORAGE, ALASKA 99511
(907) 344-4551
FAX (907) 344-2130
CHECKED BY
DATE
SCALE
ROCKFORD CORPORATION
P.O. Box 111706
ANCHORAGE, ALASKA 99511
(907) 344-4551
FAX (907) 344-2130
S,EET ,0 ?" OF
CHECKED BY. DATE
SCALE
Municipality et Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG ~ PERCOLATION TEST
DATE
I.EGAL DESCRIPTION: .~r'//'~ ~'~O~¢r,...'71 ~---~.,,JL,ANJ~ Township, Range, Section:
SLOPE
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
O~,olh LO Wilcr
M0niU~ring? DiI~'
~$
PERCOLATION RATE /~"-
TEST RUN BETWEEN ~'
SITE PLAN
· "~o //Z' ~ ,4vF.
Ne~ Depth to Net
Time ~'~.at er Drop
L ~_s_d~" ~ ~'"
(minules/inch} PERt HOLE DIAMETER
_ FT AND., '~ ~/'F_. FT
/'/V'/
Et) BY: .... I ~
~ --~ ~ -" ',,.,cH III-y'THAT T~IS TI~ST WAS PERFORMED IN
2CORDANCE WITIt ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATL DATE' ?//~/~ '~-,-,
Munlcipalily of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG ~ PERCOLATION TEST
PERFORMED FOR:._ ~'~J"r ~.~..,y Z-J DATE PI
LEGAL DFSCRIPTION= /-~:~T' /1, ~/..O¢.J~..'7,~ CL-~"E't,./6,~ow~nship, Range, Section:
('°-I-'/0~-~ A~-~ I C- ~ s LOP E
SITE PLAN
WAS GROUND WATER
ENCOUNTERED? ,~O
N
©J-
I
IF YES, AT WHAT
DEPTH?
Monitoring?
Reeding
?/,//q
Tired
$ .' $0
Net
Time
/5'
Net
Drop
PERCOLATION RATE /~'
~:~"
-- (mlnutes/inch) PERC HOLE DIAMETER ~
TEST RUN BETWEEN ~' FT AND S Y~.~ FT
, ~-~.~Y THAT T~IS TEST WAS PERFORMED IN
TH- ~
7-19-7b,
ORGANIgS
SILT, TRACE SAND
SAND, TRACE SILT AND GRAVEL (SP)
0o0~
0,5'
SILTY SANDS TRACE SP, AVEL (SH)
7°0I
8.0~
GRAVELLY SAND SOHE SILT (SP)
NOTE:
Engineering E~ Geological Consultants Inc.
16.0~
NO WATER TABLE
Test hole excavated wlth tractor-mounted backhoe.
JIH HARSHALL PROPERTY
LOG OF TEST HOLE
ANCHORAGE, ALASKA
ow~ em BH e~'~om'~D ~"~X~.NO. h6206q
c?,,¢'.Z
,
,I
I hereb~ certify that I have ~eyed ~e foUo~]
~nuehornRo Recording Precinct ~Jaska, ~n~ thor the
provement$ ~ {u~led thereon are within th~
llnea ~nd do not overlnp or ~ncron~h on th~ ~ertr
lying adjacent thereto, (h~ no Jmprov~menta on prop-
erty lyJn~ a~Jncent thereto encroach on the
queatlOn nnd thnl there ~re ~o ~adw~y$, ~ansmisalon
Hne~ or other v~lble e~omenl, on I~ld P~pe~ except
n~ Intllen~ed hereon,
D~ted nt Anchorage,
March 24, 1992
Municipality of Anchorage
Department of Health & Human Services
P.O. Box 196650
Anchorage, Alaska 99519-6650
Attention: John Smith
Reference: Lot 11, Block 7, Greenland Subdivision
Subject: Adequacy Test
Dear Mr. Smith:
On August 29, 1992, I inspected the septic system on Lot 11, Block 7,
Greenland Subdivision and performed ail adequacy test on the existing crib
type absorption system. Prior to the visit I reviewed all documentation
available on the system including an adequacy test completed in 1980 by
R & M Consultants (results attached). At the time of the test the crib was
dry which appeared suspicious because the septic tank had been pumped
the previous day and the pumper may have also pumped the crib.
Since the crib was dry I assumed it was either absorbing the septic
effluent efficiently or had been previously pumped. The depth to the
bottom of the crib was measured at 13.5'. I then began pumping water
into the crib at the rate of 6 G.P.M. and continued pumping for 2 hours and
10 minutes. Total water pumped into the crib was 780 Gallons. The water
surface was measured at 7.2' from the top of the crib. This information
appears contradictory with that obtained by R & M during their test in
1980 because their data indicutes the addition of 600 gallons of water only
raised the liquid level .65', Tim only feasible explanation is that the lower
portion of the crib is partially plugged reducing the capacity and
absorption rate of the crib.
After tile addition of tile water 1 monitored the drop in tile crib over the
next several hours. After 4 hours tile water level had receded to 9.0' from
the top of tile crib. It appeared at this time the crib was absorbing water
at an acceptable rate. 1, there,'ore, discontinued monitoring the water level
and submitted the paperwork for llealth Authority Approval.
Municipality of Anchorage
Department of Health & Human Services
September 11, 1992
Page Two
On September 1, 1992, I again checked the water level and measured it at
9.2' from the surface. After initially receding 1.8' in 4 hours the level had
only receded .2' in tile succeeding 3 clays. I brought this to the attention of
Robbie Robinson of the Municipal staff and requested he hold the Health
Authority Approval for this lot in abeyance while I conducted another test
of the system.
On September 7, 1992, the water level in the crib was measured at 9.2'. A
total of 360 gallons of water wits added which raised the water level to
8.2'. The witter drop was then monitored over time. On September 8 the
level had droppect to 8.5' indicating an absorption of 108 gallons in a 24
hour period. On September 11, 1 again measured the level and found it to
be at 8.9'. After 4 days the crib had still not absorbed the 360 gallons of
water. The results of the second test iudicate the crib is incapable of
absorbing tile minimum requirement of 600 gallons per day its mandated
by Municipal criteria roi' a 4 bedroom house. I, therefore, submitted an
application for a permit to upgrade the septic system on this lot to replace
the crib and install a shallow trench system capable of accepting the 600
gallon per clay minimum.
Sincerely,
Michael E. Anderson, P.E.
1980
No. 051001-36
· ee Houston
101Benson Blvd.
302
A~horage, Alaska 99503
Adequacy Test on Existing Sanitary Sewer System;
Greenland Subdivision, Anchorage, Alaska
Mr. Houston:
Lot
11, Block
i.iy~yrl request of May 28, 1980, we conducted a test of the sanitary sewer
ystem on the above described property.
the house had been vacant 3 months the seepage pit was saturated wit~
U galllons of water prior to the test. During the test the liquid level
seepage pit was measured before and after the addition of 600 gallons
The total depth of the seepage pit was 13.8 feet.
· were measured below the top of the standpipe and are
[0ilg~'i:g table:
[~itial Water Second 24 hour
ading Added Reading Reading
~a 1 lons)
shown ~n the
Total .
0.85'
gS' 600 10.30' Il. 15'
level rose 7.8 inches with the addition of 600 gallons of water,
Lng a capacity of 76.9 gallons per inch. Twenty-four hours later ~e
level was again measured and found to be 11.15 feet. It had dropped
?feet or 10.2 inches. This indicates an average effluent acceptance rate
.78,4 gailons per day for the surrounding soils. If the 4 bedroom residence
Lee Houston
Page -2- ·
m: ~he property is to house 8 people~ the average load on the ~yst~ c~n b~
expected ~o be 600 gallons per day. We can therefore conclude ~t~'
system is disposing of effluent at an adequate rate for ~ 4 bedr0om:~:
residence.
appreciate this opportunity to be of service to you.
· Y°ulhave any questions regarding this
service to you.
cry truly yours,
Please contact ua iff,
letter or if we csn be of additional
R~
CONSULTANTS, INC.
~e ' Cecere
ect Manager
h)ATaSI-P
Tom Fink,
Mayor
3¢lunicipality of Anchorage
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
January 8, 1991
Robert A. and Glenda Brown
4721 East ll3th Avenue
Anchorage, Alaska 99516
Subject: Lot 11 Block 7 Greenland Subdivision
Permit #900208, PID #015-171-14
The subject permit, issued by this office for a single family
well and/or on-site wastewater system has expired as. of December
31, 1990o
A new permit must be obtained from this office for a well and/or
on-site wastewater system noq installed by the expiration date.
If you have drilled the well, a well log needs to be sent to
this office for documentation of the installation and to close
the permit.
If a private engineer inspected the installation of the on-site
wastewater system, the original as-built inspection report
(three-part form) must be sent to this office for review,
approval and documentation. All 'inspection reports must be
submitted within 30 days of construction completion.
When applying for a new permit, the ~ees are: $90.00 for an
on-site wastewater permit; $50.00 for a well permit; $140.00 for
a combined on-site wastewater and well permit.
!
If you have any./., questions,
SinCerely, ^ 7"
//
P~bgr am Mar~ger
On-site Services
JW/ljm:200
please call this office at 343-4744.
enc: Copy of Permit
"Kids Are Our Future"
/
/
i:,::~:!; ' :MANAGEMENT AGREEMENT
~TiJE: JJNOERSIGNE~OWNER hereby employs th~ undersigned Broker exclJislvel)' t~ rent, lease, operate an.~d manage the r~a prope.Lty situated in
~:': . ~ ~-:+ * ' ;~ ............ T'i'"'~'"'~'~ ...... ';'~*~'"~'~r~.~m~..~. ~[ate or ~..f..~.~.~. ~e.~
; ;deseflbea ~s ~ ...L...~. J ~ ~ ! I ~ _.L.I~ , ~ ~ ~ I ~ .......................................................
................................. ~..~j~j ........ .......... ~. ...............................................................
~ ~ .................................................................................................. (~ ..~:.~. ,;~ ~. ...~..~..,..~ .... ~. .............. . .....................................
::~ · . BROKERS OBLIGATIONS, , .
: uwner nere~y comers upon the Broker the fo ow ] R,~ dutles,(authority a~d pO~et~
?.? ~ '1~ LEASING. To advertise the ~v~lJabl~ fo} ~nf~of the'.p~pper[~ ~r,ady b~rt~ihe?eof and to'd spey For EenJ .or For Lease siBns thereon to execute
:[eases for terms not to exceed.. ~.~ Y~a~S, renewals or can~eJJa'tio~s'~f lea~es relalJnR [o the property'~ [~rm{n~te tenancms an~ to sJ n and
;for the Owner such notices as Broker deems aro riate to In ' ' ~ serve
rem sas to recover r~nJs a~d o PP p I st tulo era ~c[Io~ I~ the name of I e Owner [o ev ct tenants a~d recover possession of [ e
lP , thef sums duel to settle, compromise and release such actions.,
~, ~ENtS To collect re,ts and to co act ahd d sbuKSe secu[ity and other de~es J~ [o de~os [ a r~ce pts collected for Owner
qualified bankln~ I~sllJu[io~, but Broker sfl~ll.~bt Incdr any ha~ilJty for bankr~p[o~ o~ fatl~re 6f the depostto count wilh
::~. MA~TENA,C,. ~o~ploy, supervise' and d'scherEe al abor requ red for [,e operat,oa a,d maintenance~'f the property,
4. S~RVlCE CoNTRAcTS. To execute co~ttac~s: for utilities and setvces fo~ the o~eratlo~ naintenance and safety of the property as the Broker shall
~ RB~AiR~. To fake chorea of repairs, decoraUn~d alterations and fo purchase supplies therefor. Broker aErees to obtain Ow.er s prior authorization for
y ~n~ e~ch eXp~,se.l[e~ ~n ~cess ~f.~..;...Z.~......~..~ ..................... except monthly or recurrinE o)eratinE choreas or emer enc re airs or ,u
Tent t~e ~w~er IS. not (easo~amy aVallame rot consultation, if the Broker deems s~ch ex~,e~ditures in ....... ~ ,~' .............. ~- ~ -P , . .' lh~
me property trom ~amage or to perform services to the tenauls provided, for In their leases~..
6. DISBURSEMENTS. To accrue end make d~sbursements from Owner s f~nds for co~tractua mortgaEe payments, ~operty and employee taxes, special
aSseSsmehts, premiums for hazard and liability InsUrance and any other insuraHce requked, except as follows:
~Y.'FERJ6~IC STATEMENTS To ~ender per od c itemized state nents of race pis, expenses, charges and accruals and to rmui[ to Owner receipts less
~isbursements ~nd ~ccrua s for future expenses n the event disbursements sba I exceed race pts, Owner shah promptly ~emlt s~ch excess tO the Broker. Owner
: assume~ full respohslbJlity for the payment Of a~y expenses and obligations I~c~rred In Cb~nectJon with the exercise of ~roker s duties Set forth herein.
,:; ~ ~ . WNER S OBLIGATIONS ·
. .~.=i~ BRO~RAGE'~ES Ow~et 8Erees JO pay BrOker a re? or fees for serv ce~ re'dared a~ the rates hereinafler set forth. Owner recognizes Broker ns ~eat
'-..;~ ~:;l~ ~ny ~oJlajlo~s~r~l~t ~e [o the prop~Hy of ~y part thereof, wh ch ~ay E~v~ b~en I~i[lated ddrinE the term hereof, and If consummated shall Compensate
~; ~ ~: Bro~f I~ accord~n~ W~h the rates hereinafter set forth. Such compensetJoa i~ due ahd payab e on de and and n ay be deducted by the Broker from receipts
... ................
........................ . ...................... . .................................................................
,.. :': ~lleraflo~'Dodernlz~to, redecor~ on ~'~ ...........................
.......................................................................................................................................................
~. hOLD HARMLESS Owner a~reos tO hO d' ~e Broker' ~ mJess from a da n~Ee Suits l~ connection will he aneBement of t e here, deScr bed property
and fro~ liability, from InJuiy ~ffered by ~ny eh ployee or other ~ersofi w icOn,ever and lo cur y, al his ow~ expea~e adequate pub e ~ ab tv a~d Worhmen s
Broker s compensation or f Broker successfu y defends any action brought age nsf Broker by Owner, relaling to the property, or Broker s management thereof,
Owner agrees to Pay all costs incurred by Broker in connection with such action, mcludJnE a reasonable attorney's fee.
:J~ DATA AND RECORDS. Owner aFee~ lo make available to Broker all data, records and documents pertainJn~ to the property which the Bto~er may
r;f'equlte lo properly exerc se his dutleshereuuder.
OTHER TERMS
oGRE'-ER ANCHORAGE AREA BOr'UGH
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECI'ION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
NAME Jim /'/df/¢,s/u?zz. MAILING ADDRESS ~"-~./~/'¢~ ~O/~ /L~6~PK
LEGAL DESCRIPTION ~2,7-
LOCATION
SEPTIC TANK:
DISTANCE
~,~/
FROM WELl. /¢~.- ~ MANUFACTURER,,.~,~_[¥..%,LAt
INSIDE LENGTFI ..... INSIDE WIDTH
NUMBER OF
/
MATERIAL _ ,/6/-"/,~ 'i -~ ~'?. <i -:,'~ COMPARTMENTS
l
.LIQUID DEPTH LIQUID CAPACITY ///~;~; ~ GALLONS.
SEEPAGE Pit:
NUMBER OF PITS / DIAMETER '~
LINING MATERIAL ~O~/) CRIB SIZE:
BUILDING FOUNDATION , NEAREST LOT LINE
OR WIDTH _ LENGTH /~ DEPTH //
' '
DIAMETER 5~¢t~DEPTH '~ ! -- ~.
. DISTANCE FROM: WELL
~ TOTAL EFFECTIVE
ABSORPTION AREA (WALL AREA) SQ. FT.
ADDI-FIONAL ABSORPTION
WELL_:
TYPe ~t~ (0~O '%~ D
BUILDING
FOUNDATION
CESSPOOL
APPROVED
CONSTRUCTION _ [/~ ~/.. L ~:7.)) DEPTH
NEAREST NEAREST SEPTIC
LOT LINE SEWER LINE_ TANK
OTHER SOURCES
DISAPPROVED REMARKS
DISTANCE FROM:
SEEPAGE
SYSTEM
DISTANCES: ~-~ ,S/~/~0&/
INSTALLED BY: ~.~[~,¢~F ~/(C,
PIPE MATERIAL:
LOT SLOPE:
REMARKS:
Form No, LQ-031
DIAGRAM OF SYSTEM
APPROVED ~?.>I.L.'J_.,3
G.A.A.B.
SEWAGE
GREATER ANCHORAGE AREA BOROUGH
D~.PARTMENT OF ENVIRONMENTI-t,L QUAI. ITY
3330 "C" STREET ANCHORAGE:, ALASKA 99503
T g LE, PI-IO N E 274-4 ~,6 l
DISPOSAL SYSTEM -- APPLICATION AND P~:RMIT
PERMIT NO.
INSTALLATION LOCATION :¢
INSTALLATION OF: SEPTIC TANK --.~ SEEPAGE PIT__
TYPE AND SIZE OP FACILITY TO BE SERVED
COMPLET]ON ,ATE ANTICIPATED ~/
NOTE~ THIS PER~Cl]'F IS NOT VALID WITHOIJ'r SOIL TEST
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFII.LING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONN~ENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
/~O~ TYPE ~~~'*gE AREA S,,E ~¢
~INIMUI¥I DISTANCES, REqUIREmENTS
FOUNDATION TO SEPTIC TANK
FOUNDATION ]O SEEPAGE PIT
SEPTIC TANK TO SEEPAGE PIT WALL
SEPTIC TANK .... ~ SEEPAGE
TO NEAREST LOT LINE.
WELL TO SEP'FIC TANK t
DRAIN FIELD __.
WATER MAIN TO SEPTIC TANK __
DRAIN FIELD
...... DRAIN FIELD
DRAIN FIELD
SEEPAGE PIT
ALSO CONSIDER AREA WELLS,
__. SEEPAGE PIT -
SEPTIC TANKi __F~-- SEEPAGE PIT ..... DRAIN FIELD
TO P, IVER, LAKE, STREAM.
CAS'r IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION 5 FEET INTO UNDISTUIRBED SOIL.
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION,
OR
R&M
Civ#£ngineers
ENGINEERING & GEOLOGICAL CONSULTANTS
229 EAST Blst. AVE. - P.O. BOX 6087 - ANCHORAGE, ALASKA ggs03 TELEPHONE 907-279-0483 TELEX 090-35419
Geologists Land Surveyors
JAMES W. ROONEY, P. E.
RALPH R. MIGLIACCIO
MALCOLM A. MENZIES, P.E., L.S.
JAMES H. WELLMAN, P.E.
D~PT, OF ~ ~'NrAL C~UALIT¥
Engineering Geologist.
August 8, 1974
R & M No. 462064
Mr. Jim Marshall
2716 Strawberry Road
Anchorage, Alaska 99502
Re: Test Hole and Soil Log Report for Sanitary System
Lot 7 Block 11 Greenland Subdivision
Dear Mr. Marshall:
We are submitting herewith the test boring results and our comments
regarding soil conditions encountered at the subject site. This
investigation was performed in accordance with your request of July 19,
1974, and those procedures outlined in a letter dated Septmeber 13, ].971
by Mr. Rolf Strickland of the Greater Anchorage Area Borough Department of
Environmental Quality.
A single test hole was put down within the Lot 7 area for the purpose of
defining general subsurface soil conditions for the proposed sanitary
system. Excavation was accomplished with a tractor-mounted backhoe and
the test hole was extended to total depth of 16.0 feet below ground sur-
face. The final log prepared for the test hole has been included in
Drawing A-01.
Ground water was not encountered in the test hole.
We appreciate being given this opportunity to be of service to you.
Should you have any questions with regard to the above, please do not
hesitate to contact us.
Very truly yours~
R & M ENGINEERING &'GEOLOGICAL CONSULTANTS, INC.
Rooney
JWR:kd
xc: GAAB
TH-1
7-19-74
ORGANICS
SILT, TRACE SAND
0.O'
0.5'
I .5'
SAND, TRACE SILT AND GRAVEL (SP)
SILTY SANDS TRACE GRAVEL (SM)
8.0'
GRAVELLY SAND SOME SILT (SP)
NOTE:
16.0'
NO WATER TABLE
Test hole excavated with tractor-mounted backhoe.
Engineering ~ Geological Consultants Inc.
R~ ANCHORAGE FAIRBANKS ALASKA ,JUNEAU
JIM MARSHALL PROPERTY
LOG OF TEST HOLE
ANCHORAGE, ALASKA
Municipality of Anchorage
Development Services Department
BuiIding Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.cLanchorage.ak.us
(907) 343-7904
O
.- %:;
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. O1 ql '71 1/,
1,
GENERAL N
Complete legal description IL0t 11 ~'Bk ?,
Location (site ad, dress or directi(~n~)'/,'72i .E. 11 '~-.b.
Current Proper~owner(s) Thomas'.E . & El'isabeth
Mailingaddres~:..'-...~ P,0- m-,¥ 09Al'~.. . Anchorage.
Lending agency '- ".-.Seat%ie: Nort~aee
HAA#
Expiration Date: '.
Greenland Subdivision
Windi~phone q0'7-336-1~'7
Mailing address
Real Estate Agent
· Mailing Address
~00 B Street. Anchora~*.
Assist2Sell
8001
Unless otherwise requested, HAA will be held by DSD for pickup.
2, HUMBER OF BEDROOMS:
3. -TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
Dayphoneg07-562-5626
Dayphoneg0?-33R-?~R?
TYPE OF WASTEWATER DISPOSAL:
[] Ir;dividual On-site ~
Individual Holding tank
Community On-site
[] Public Sewer
The Municipality of Anchorage Development Services Department (DSD) Issues Cedificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of
title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water
supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are
valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with
new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with
valid Water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public
water system· The Municipality of Anchorage is not responsible for errors or omissions in the professional
engineer's work.
4, STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verif7 that my investigation,
based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of
bedrooms and bjpe of structure indicated herein. I furlher verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,
and regulations in effect at the time of installation.
"~-'- O C.-. 7o ~c.~ F__ -'~. ~v... 907-269-7612
Name of Firm, ~'~ ~ ?,'~." ,/.??? Phone
Engineer's Pdnted Name DouF3. a.~ W. PoaEe Date 9/2':;/01
~,~',~T.' ·
::'~
S. DSD SIGNATURE
Disapproved.
Conditional approval for
ENGINEER'S
STAMP
bedrooms, with the following stipulations:
Additional Comments
Attachments:
HAA Checklist
Septic System Advisory
Well F. Iow Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
Original Certificate Date:
M-nicipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(~07) 343-7~04
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Descdption: Lot 11 Bk 7~ Greenland Subdivision ParcallD:01517114
WELL DATA
Well type Dnmestic
Date completed
Total depth 9 5 It.
If A, B, or C provide PWSID #
Sanitary seal (Y/N) y
Casedto 95 ft.
FROM WELL LOG
Date of test
Static water level Sc) ~ fl.
Well productioo I 5 g.p.m.
Well Log (Y/N) ¥
Wires properly protected (Y/N) ¥
Casing height (above ground)l ~ - 6
AT INSPECTION
9/a/0
31 ft.
~ 2.8 g.p.m.
in.
WATER SAMPLE RESULTS:
Date of sample: ~" I ~ ' ~ I
%
Other bacteria t, ve'rre colonies/100 mL
Collected by: T)~'5
B, SEPTIC/HOLDING TANK DATA
Tank T. ype/M.at~ial non-detect
Td~ k'E;' 1 2 5 0 . ~d. :. Number of Compartments
, F~ndafl~ ~~)':'Y
".' .- ' Ii'/~'oO
~ Date of pumpi~ ~/~./~!:'
Date installed 10/6/92
Cleanouts (Y/N)
Depressioo over tank (Y/N) N High water alarm (Y/N) N
Pumper"At He)me
c.
*'Data installed~'? Soil rating (g,p.d.~t~ or ~/txtrm), 8 gpd/s£System type shallow trench
2 ea $45~* each
Length :90 ~' ft. Width 5 ' ff. Gravel below pipe 3 ' ft.
Totaldepth $ fi. Eff. absorptionerea 776 ~ Monitodogtube ~{
Date of adequacy test q/R/01 Results (Pass/Fail) ~
Fluid depth in absorption field before test (~ in. Water added ~OO gal.
Elapsed Time: .5.4.0. min. Final fluid depth 1 1
Any rajuvenatio~ treatment (past 12 mo.) (YIN & type)
Depression over field N
Fo*' 4 bedrooms
New dept~4' 4'~n.
in. Absorption rate >= 6~0 g.p.d.
N If yes, give date N/,~
D. UFT STATION
Date installed
'Pump on" level at in.
Datum
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/tiff station on lit 1 01 t
Absorption field on lit 1 f~ ~ t
Public sewer main N/A
Sewer/septic service line R (~ ~
Curtain drain
Manhole/A_ _,:ce~_ _s (Y/N)
High water alarm level at
Meets almm & circuit requirements?
N/A
Size in gallons
'Pump oft" level at __ in.
Cyctes tested
in.
HAA Fee $
Date of Payment
Receipt Number
(Rev. 12/00)
o. E.G,.EER'S CE" FtC TIO.
I certify that I ha~ dete~in~ thm~h fie~ ins~ a~
mv~w of Muni~l m~s ~at ~e a~ sy~e~ am t~
~. ~ WaNer Fee $
/~/~/~ / Date of Payment
F. COMMENTS
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 23t Propertyline.J~..~_ Absorptlinfield ~,~
Water main ~1 Water service line ,- ¥ ~,o Surface water + ~Oo/
Wells on adjacent Iote+1 00 ~
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 1 3 ~ Building foundation 32 t Water main
~ 'in a. reaDflveway, pad(lng/vehicle storage
Water Service line ~.-4 ~0 Sudacewata~,.Non-{,e
Wells on adjacent lits 1 nc) ~
On adjacent l/ts -I- 1 0 El ~
On adjacent lots -~ 1 ~ h ~
Public sewer manhole/deanout
Holding tank ~)~
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
Parcel I.D. # ~J\~"~ - ~'-~ !- ~,'U/
1. GENERAL INFORMATION
Complete legal description
Location (site address or directions) ¢7Z_. / -~-', //~j '?--~ /Crv',-"
Property owner _~'~
Mailing address
Lending agency
Mailing address_
Agent
Address
phone
Day phone
Day phone
Unless otherwise requested, HAA will be held for pickup,
NUMBER OF BEDROOMS:
TYPE OF WATER SUPPLY:
Individual well
Community well
Public water
NOTE:
If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
TYPE OF WASTEWATER DISPOSAL:
Individual on-site
Holding tank
Community on-site
Public sewer
NOTE:
.×
If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025 (Rev. 1191) Front MOA #21
'"/ /r,%~) /
sluewwoo leUOp,!pp¥
:suop, elndp, s 6U!MOllOt eq~ H:HM 'SLuompeq
'SLUOOJpeq
JoJ. leAoJdde leUO!l!puoo
'pe^oJddesio
JOJ peAoJddV ~
=~t:ln.l.~fN OIS SHHQ
'9
2O~Oh~ ~ ~..LZ. Oh"Z '~O~J 'O~_ BseJppv
euoqcl ?('v/?~/v.,,2 pv~ IvO :5~lL;-)qrvy wJ!=l to eLUeN
'uo!loedsu! s!ql to elep eLtl UO loeJte u! suo!jelnSeJ pue 'seoueu!pJo
'sepoo elels pue led!o!unl/N lie ql!M eoue!ldLUoO u! s! LuejsXs lesods!p JaleMe~SeM Jo/pue Xlddns
JeleM elis-uo eql 'uo!loedsu! pue uo!leB!~SeAU! XLU mOJI pue sel!t eBeJoqouv ~o Xl!led!o!unR eLt~
LUOJt peu!elqo Uo!1eLUJO~U! eqj uo peseq ~eLt1Xtpe^ JeLllJnJ I 'u!eJeq pe~eo!pu! eJnlonJls ¢o ed~ pue
SLUOOJpeq tO JeqLunu ell1 ~O~ elenbepe pue leuo!~ount 'etes s! guelsXs lesods!p JeleMelSeM Jo/pue
Xlddns JaleM elfs-uo eq~ leq~ SMOHS uo!leO!ldde leAoJddv Xlpoqlnv qlleeH s!ql ¢o uo!leB!lseAu!
XLU leql XIpeA I 'MOleq UMOqS elep uoileP!leA eql lo se pue oleJeq pexitte Fees XuJ ~q pe!t!ueo sv
U=I:~NION~I AG NOIJ. O~idSNI dO J.N~IN~t.LV.LS 'g
Legal Description:
A. WELL DATA
Well type
Log present (Y/N)
Totaldepth
Sanitary seal (Y/N)
Municipality of Anchorage ~,(~11 ~ [ V, ~ 1)
Department of Health & Human Services -
HEALTH AUTHORITY APPROVAL CHECKLIST ' 7 't9L, 2
Dept. I"le~lth ?.~ 14urnail'S'~,:~;es
If A, B, or C, attach ADEC letter.
Y Date completed ~//~t ~ / (¢ O Driller
E)~ I Cased to q 5 i
Casing height
Wires properly protected (Y/N)
ADEC water system number
Date of test
Static water level
Well flow
Pump level
FROM WELL LOG AT INSPECTION
/'~ g.p.m. ~
5~7' 5~7 ~
g.p.m. - ~/
SFPARATION DISTANCES FROM WELL TO:
Septic/holding tank on lot
Absorption field on lot
Public sewer main
Sewer service line /k.//~
/¢,V~
//0 /
; On adjacent lots
On adjacent lots
Public sewer manhole/cleanout
Petroleum tank
I
I
'>/00
WATER SAMPLE RESULTS:
Coliform ~)
Date of sample:
Nitrate /NJ. 'b.
//~L* Collected by:
Other bacteria
B. SEPTIC/HOLDING TANK DATA
Date installed /0/~/~7~ Tank size
Cleanouts (Y/N) Y' Foundation cleanout (Y/N)
High water alarm (Y/N)
Date of pumping
Compartments
Depression (Y/N)
/k.J Alarm tested (Y/N)
"T-~ ~ Pumper /N///~
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO:
Well(s) on lot /~
To property line
Surface water/drainage
On adjacent lots
Absorption field
Foundation
Water main/service line
72-026 (Rev. 7/91) Front CONTINUED ON BACK PAGE
C. LIFT STATION
Date i n st a I I e d'~"'"'--~ .........~
Size in gallons
Vent (Y/N) "Pump on' at~''''''--.level
High water alarm level '""'"~es tested
Meets MOA electrical codes (Y/N) ~
SEPARATION DISTANCE FROM LIFT STATION TO:
Well on lot On adjacent lots Surface water
Date installed
Length ~(-~ t
Total absorption area
Depression over field (Y/N) /'%,]
Results (pass/fail) ~ ~ ~;
Peroxide treatment (past 12 months) (Y/N)
Manufacturer
Manhole/Access (Y/N)
"Pump off" level at
D. ABSORPTION FIELD DATA
Width
'7'7
Soil rating ~ ~-~P --r:. System type ~_JCALL0~d
/ ~ !
Gravel thickness '~ Total depth
~ ~ Cleanouts present (Y/N) ~
Date of adequacy test ~%g
for (~-O L] IL-. bedrooms
If yes, give date
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
Well on lot
To building foundation
On adjacent lots I"~1/t~
Surface water
Curtain drain
170 /
On adjacent lots /¢)
~-- ~:~ To existing or abandoned system on lot
Cutbank /%'///~ _Water main/service line
Driveway, parking/vehicle storage area
E. ENGINEER'S CERTIFICATION ~ ~//L4/;7
i
/o
I certify that I have checked, verified, or conformed to all MOA and HAA guide!ines in effect on the date of this inspection.
Signature
Engineer's Name
Date /0/7
HAA Fee $
Date of Payment
Receipt Number
Waiver Fee: $
Date of Payment
Receipt Number
Lo --F- II
~ATE R~CEIVED /
- INSPECTION APPOINTMENTS ~A~{-~
TIlde TIME TIME
DATE DATE DATE
INSPECTOR INSPE~TOBF
INSPECTOR --~ v v
~UNICIPALITY OF ANCHORAGE ~NV/RONMLh:L'~L
825 L Street- Anchorage, Alaska 99501 Iv)AY
ENVIRONMENTAL SANITATION DIVlSIONTelephone 264-4720 REC[I VE
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES
DIRECTIONS: Complete eIl p~r~s on p~ge 1. hmomplete requests will not be processed. Please ~llow ten (10) d~ys for processing.
1. PROPERTY O~NNR PHONE
MAILING ADDRESS
PHOPERTY ~ESIDENT (If different from above) PHONE
2. BUYER PHONE
MAILING ADDRESS
3. LENDING INSTITUTION ~ PHONE
MAILING ADDRESS
4. REALTOR/AGENT ~ PHONE
MAILING ADDRESS
5, LEGAL DESCRIPTION
STREET LOCATION
6. TYPE OF RESIDENCE NUMBER OF~BEDROOMS
[] One E~] Four
',~a_ SINGLE FAMILY [~] Two [] Five
[] MULTIPLE FAMILY ~ Three [] Six
[] Other
7, WATER SUPPLY
~ INDIVIDUAL* *ATTACH WELL LOG. Awell Icg is requlreo for all wells drilled
[] COMMUNITY since JuL!e 1975. For wells drilled prior to that date, give well
[] PUBLIC UTILITY depth (attach Icg if available.)
8. SEWAGE DISPOSAL SYSTEM
~ INDIVIDUAL/ON-SITE** t~l q ~'1 YEAR ON-SITE SYSTEM WAS INSTALLED.
[] PUBLIC UTILITY
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-010 (Rev. 6179) ~,
[1 .....,~..,_ C-Jr /~'
THIS SIDE FOR OFFICIAL USE ONLY .,
I. TYPE/OF RESIDENCE NUMBER OF BEDROOMS
~ SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER
[] MULTIPLE FAMILY [] TWO [] FOUR [] SIX
I~~ INDIVIDUAL DEPTH OF WELL
[] COMMUNITY
DATE DRILLED
[] PUBLIC UTILITY
Connection Verified LOG RECEIVED
3, SEW,,~AGE DISPOSAL SYSTEM PERMIT NUMBER
EZiI'N DIVIDUAL/ON -SITE DATE INSTALLED
[]PUBLIC UTILITY / I "7
Connection Verified INSTALLER
[~eptic Tank or ~Holding Tank
Size: /~ If Tank is homemade SOILS RATING
give dimensions:
TYPEOFTANK ~ ~ MANUFACTURER
4~ DIST~G~SW[kL TO: Septic/Holdin~ Tank Absorption Area Semer kine ~aarest lot tine
ABsorptioa Area to nearest Lot Lino
5. COMMENTS
~ ~NDITION'AL APPROVAL (letter must accompany certificate)
~DISAPPB0VED
825 "L" S-FR EET
ANCHORAGE, ALASI<A 99501
(907) 264 4111
~1[ f~A[~ rt4[:!,Jl OF Iii ,:~1 rtl AIWD ENVIRONMEFNTA[ PROTECTION
May 29, 1980
John F./Carolyn A. Hanrath
% 3009 West Camelback Road
Phoenix, Arizona 85017
Subject: Lot 11 Block 7 Greenland Subdivision
Approval for your individual sewer and water facilities
can not be granted until the foil. owing items have been
completed:
(1)
The water analysis report ]De delivered to this
department from Chem Lab, 5633 B Street, for
our review.
(2)
The septic tank pumped with a receipt submitted
to this department.
(3)
~] adequacy test be performed on the existing leaching
area. This test will determint if the system is
adequate according to National Standards. A listing
of private firms performing the test is enclosed. This
report needs to be submitted to this department for
our review.
If there are any further questions, please call this office
at 264-4720.
Sincerely,
Les N. Buchholz, R.S.
Senior 'Environmental Specialist
LNB/ljw
CC:
National Bank of Alaska
Pouch 7-025 99510
Lee Houston
% Lee Houston and Associates Ltd.
101 Benson Boulevard - Suite 302
99503
LEE HOUSTON Ex: ASSOCIATES, LTD,
- F{EAL ESTATE-
June 12, 1980
SUITE 302, 101 BENSON BUILDING
ANCHORAGE, ALASKA 99503
(907) 276-5909
Les N. Buchholz, R.S.
Senior Environmental Specialist
Municipality of Anchorage
825 L Street
Anchorage, AK 99501
RE: Lot 1'1, Block 7, Greenland Subdivision
John F. and Carolyn A. Hanrath
Attached are copies of:
1) Chem Lab's water test
2) Isaac's septic pumping report
3) R&M's adequacy test report
If anything further is needed, please let me know.
Sincerely,
Broker
LH/jh
June 6, 1980
Lee Houston
101Benson Blvd.
Suite 302
Anchorage, Alaska 99503
Re:
R&M No. 051001-36
MUNIciPAL/TM ©F ANCH©RAGE
DEPT. OF i ,t,'.~ ,~:
ENVIRoNMENL~,L ;, . ~CTION
RI CEIV D
Adequacy Test on Existing Sanitary Sewer System; Lot 11, Block 7,
Greenland Subdivision, Anchorage, Alaska. For Professional Services
Rendered through June 4, 1980.
Dear Mr. Houston:
The following is our invoice for professional services rendered on the above
referenced project.
Invoice No. 051001-36
Professional Services
$300.00
Total Invoice No. 36 $300.00
Please note our invoice number on your remittance. Should you have any
questions concerning this invoice, please contact me or the Project Manager,
Ms. Janice Cecere.
Thank you,
R&M CONSULTANTS, INC.
C. ~-:"Parisena
Anchorage Office Manager
CJP/j h/13-M
June 6, 1980 R&M No. 051001-36
Lee Houston
101Benson Blvd.
Suite 302
Anchorage, Alaska 99503
Re: Adequacy Test on Existing Sanitary Sewer System; Lot ll, Block 7,
Greenland Subdivision, Anchorage, Alaska
Dear Mr. Houston:
Per your request of May 28, 1980, we conducted a test of the sanitary sewer
system on the above described property.
Because the house had been vacant 3 months the seepage pit was saturated with
4,250 galllons of water prior to the test. During the test the liquid level
in the seepage pit was measured before and after the addition of 600 gallons
of water. The total depth of the seepage pit was 13.8 feet. All liquid
levels were measured below the top of the standpipe and are shown in the
following table:
Initial Water Second 24 hour Total
Reading Added Reading Reading Drop
~gallons)
10.95' 600
10.30' 11.15' 0.85'
The water level rose 7.8 inches with the addition of 600 gallons of water,
indicating a capacity of 76.9 gallons per inch. Twenty-four hours later the
liquid level was again measured and found to be 11.15 feet. It had dropped
.85 feet or 10.2 inches. This indicates an average effluent acceptance rate
of 784 gallons per day for the surrounding solls. If the 4 bedroom residence
Lee Houston
June 6, 1980
Page -2m
on the property is to house 8 people, the average load on the system can be
expected to be 600 gallons per day. We can therefore conclude that the
system is disposing of effluent at an adequate rate for a 4 bedroom
residence.
We appreciate this opportunity to be of service to you. Please contact us if
you have any questions regarding this letter or if we can be of additional
service to you.
Very truly yours,
R&M CONSULTANTS, INC.
Jan~ce Cecere
Prol ect Manager
h/AT&SI--P
1. Approval requested by:
Mailing Address:
2. Property Owner:
Mailing Address:
4.
5.
6.
GREATER ANCHORAGE AREA BOROUGH
Department of Environmental Quality
3330 "C" Street, Anchorage, Alaska 99503 274-4561
Date Received
Time of Inspection
Date of Inspection
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
FOR
Phone:
Phone:
Legal Description:
Location:
Type of facility to be inspected
Well Data:
A. Type
No. of bedrooms
B. Depth
D. Bacterial Analysis
C. Construction
7. Sewage Disposal System:
A. Installed ~/~/"~i
C. Septic Tank: 1. Size
D. Seepage Pit: 1.
E. Disposal Field: Total length of lines
8. Distances:
A.Well to: Septic tank
Nearest lot 'line
B.Foundation to septic tank
C. Absorption area to nearest lot line
B. Installer '~ "::':'.
'~' ' 2. Manufacturer '~':
Absorption Area .... 2. Material
, Absorption area
, Other contamination
, Sewer Lines ,
, Absorption area
'Q-034 (1/74) Page 1 of two pages
GREATER ANCHORAGE AREA BOROUGH
Department of Environmental Quality
3330 "C" St., Anchorage, Alaska 99503 - 274-4561
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
1. Type of Inspection: CMRO VA FHA
Mai.ling Address: S~ ~x~/~
3. Name of Buyer: ___~ $~ /cz/~_~_F
Mailing Address:
4. Name of Lending Institution:
Mailing Address: Phone
5. Name of Realtor or Agent:
Mailing Address: Phone
CONV~
__DaS Phone
D~y Phone
6. Legal Description: i //z~?/x~e~/~J ~bJ,
Location: ,9.~~r' dD~ ./"~
7. Type of Facility to be inspected:
8. Water Supply
Type of Supply: Public Utility Individual
If Individual, number of dwellings presently served
If Individual, depth of well
9. Sewage Disposal System
Type of System: Public Utility
If ~ndividual, date of installation
No. Bdrms. ~
Individual (on-site)
EQ-037 (~/74)
Page 2 of two pages m Re ~st for Approval of Individual ler & Water Facilities
Legal Description ~ , ~. ~ , ...... ~
Comments
Approved.~ ~J-' ~, ~ Disapproved Date ~'~'~"~
Approval:Valid for one year from date signed
Greater Anchorage Area Borough, Department of Environmental Quality
DIAGRAM OF SYSTEM
certify that the information contained in this request for approval to be a true and
accurate representation of the subject sewer and water facilities and these facilities
are operating satisfactorily.
SIGNED Date