Loading...
HomeMy WebLinkAboutHUNDRED HILLS 1ST ADDITION BLK 4 LT 6Hundred Hills Block 4 Lot 6 #078-191-09 () Municipality of Anchorage ,,,~','.~ >,., Development Services Department .~ Building Safety Division '~ On-Site Water and Wastewater Program, 4700 S. Bragaw SL P.O. Box196650 Anchorage, AK 99519-6650 Page [ of www.cl.anchorage.ak, us (907) 343-7904 Permit Number:. ,~' ~.4Vt O0~ ~)~ ~ 4 PID Number. I~ ? ~-- [ q [-- O ~ "-: ~odney/~/¢-/'calF WastewaterSystem: [] New [-IUpgrade ~'~tS O~rk¢;e~/~rracE. ~.p~,~J~;¢e4 ~" qqg77ABSORPTION FIELD Well: ~ New D Upgrade n. ~ ~ r. 25~"" ~4~°W~ '"l ~ '~ TANK SEPARATION DISTANCES ~Septic ~ Holding D S.T.E.P. D ~he~  Septic ~somtion L~ Holding Pubr~t~ ~ Tank F~ld Sta~on Tank S~r L~e ~ ~ t~ ~~ ilS' i o' V -' 2 "~ BENCH MARK Opo:~t ~" too,, Inspections pe~ormed by: ~{. m... ~1..~. ee~ Dates: ,.-....,~x.-v/.-~ -7--- Development Se~ices Depa~ment Approval t~.%% c~-ssol ~, ~.;..., ..... ..~ .ev~ewe~.~.~p~o~dby: ~~/~~t~: 3-21-o~ , , .......... .,~ c~. ,~, ~/I ~ ' ~ ;'-',..... ~_ ......... PERMIT NO SW000226 PAGg 2 OF 4 Municip. atit oF .A.n_c h o..r' c~ g.e. DEPARTHENT OF HE~_THAND HUMAN SERVICES ENVlRONHENTAL SERVICES DIVISION P.D. Box 196650 eAncho~'age, A.~laska 99519-6650 · Te.i.e,ohone~. 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT L£OAL LOT 6, BLOCK 4, HUNDRED HILLS #1 P.I.D. NO. 078-191-09 LOT 3 / LOT 4 / / sou,. ,o.~ [ o~x~ LOT 8 EAGLE RIVER PER.~? ~0. SWOOO22B PAGE 5 OF ~ Mumicip. a[i~c__y_~ _oF .~.0~ h.o.m g g.e. DEPARTHFNT OF HFALTH AND HUMAN SF:RVICES ENVIRONMENTAL SERVICF:S DIVISION p.n. Box 196650 OAnchomoDe, Alosko 99519-66500Telephone= 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LECAL LOT 6, BLOCK 4, HUNDRED HILLS #1 PJ.D. NO. 078-'191-09 NEW 2000 GALLON SEPTIC rBM & DBL2 C01 aT1 TH#3 PERi, IT ~'0, SW000226 PAC£ 4 OF 4 Municip. o, tit oF .A.n._c h.o.r' o, 9.e' DEPARTHENT OF HEA~THAND IdUMAN SERVICES ENVIRONMENTAL SERVICES BlVlSlON p.n. Box 196650 ·Ancho,"o. ge0 AIQsko, 99519-6650 · Tetephone, 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LEGAL LOT 6, BLOCK 4, HUNDRED HILLS #1 P.I.D. NO. 078--191--09 ST1 ST2/99.9' FINAL ~,~1~ -:';~W"2000 ~=~:~-~_ ~, 96'4'/ Is'-PT'C FINAL GRADE MT1 =90,9' ._/ MT2=90.9' C01=101,4' C02=103.3' C01=95.8' C02=95.8' NO WATER FOUND 81.9' B.O.H. A B FCO 25.5' 63.5' ST1 27,0' 83.0' ST2 40.0' 91.0' DBL1 44.0' 92.0' OBL2 45.5' 91.0' C01 57.5' 84.5' MT1 59.0' 84.5' C02 145.5' 95.0' MT2 146.0' 95.5' DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage. Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST 2 3 4 5 6- 7- 8- 9- 10- 11 Municipality of Anchorage ,.. DATE PERFORM~'F~/ WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? I~pth to Waer Idonitering? 13- 14- 15- 16 17 18 ~20/4 2O Township. Range. Section: SLOPE SITE PLAN / Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE (m~nute~'mch) PERC HOLE DIAMETER __ COMMENTS TEST RUN BETWEEN -- FT AND FT S & S ENGINEERING PERFORMED BY: ' ~ 7~'~4 ,"u~u ~'~;v=r ..... I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH AL~D~eI~IDELINES IN EFFECT ON THIS DAT~ DATE: ~ ~ /~ 0 72-008 (Rev. 4;85) OWNER OF LAND ADDRESS ~/~ ( er dfie Drfllin ' og b>. '1' SULLIVAN WATER WELLS P.O. BOX 670272, CHUGIAK, ALASKA 99567 · TELEPHONE 688-2759 I ~,~ 77/~ E ~ STATIC LEVELOF~ATERFT DATE-S~ed ' Ended NUMBER DRAW DOWN FT. GALS. PER HR KIND OF CASING : . / ~"~3 O .. KIND OF FORMATION: t, ! From O 'Ft. to '~ ! From ·; Ft.~o . From ~F Ft. to ~.J__~.__Ft. From Ft. to__Ft. From ".~-%~-~-~Ft. t~ ~"~"~ Ft. From ~'.4)'"" Ft. Io '~ I Ft. From~Ft. to Ft. From.__Ft. to Ft. Fromm. Ft. to From.__.Ft. to Ft. From Ft. to Ft. From Ft. to Ft. From Ft. to Ft. From Ft. to Ft. 'From Ft. to Ft. From Ft. to__Ft. From Ft. to_~Ft, From ~Ft. to From__Ft. to From FI. to: From Ft. to From FI. to From__,Ft. to From__,Ft. to Fromm, FI. to FI. to__FI Ft. to.~Ft. __FI. lo Ft. Fi. to _.FI. lo FI FLto Ft. FI. to Ft. FI. to Fi. _Fi. lo Ft. Ft. Ft. Ft Ft. Ft Ft. Ft. MISCL INFORMATION: DRILLER'S NAME ..... Drdhug og ' DOC Co. Oba SULLIVAN WATER WELLS P.O. BOX670272, CHUGIAK, ALASKA99567 · TELEPHONE688.2759 OWNER OF LAND /~ ~,0() ex3 LEGAL DESCRI~ION ~: ~ 6~ q ~0 tO dd~d ~]~' DATE - Started Ended PERMIT ~UMBER DEl'TH OF WELL ~// '~ ("~ Dow KIND OF FORMATION: ~ From (.') Ft. to ':~ ! Ft <--,'q~r/O~ ~ iCK'~d-(9 From From.:.:, Ft. to z. ~ Ft. (.~3 ~ ) 6:~( ~ g.~,d ~ /~-~ From From " Ft. toS;,? Ft. ~' / L, 77 .) ' ' ' '< From From Ft. to Ft. ~/ C 0 t~/~( ~d- Y From From.~Ft. to Fl, From From ~t. to~t. From From Ft. to~ Ft.. From From Ft. to Ft. From F~om Fi, to Ft. From From Ft. to_ Et From ~rom ~t, to~Ft From From. Ft, to~Ft From From. Ft. to Ft. From From~Ft. to Ft. From From~Ft. to._ Ft. From~ Ft. to_.. Fl Ft. to. _Ft.. __ Ft. to. Ft. __Ft. lo__Fl. Ft. to Ft. __Fl. to. FL __Ft. to _Ft. ~Ft. to Fl. Ft. to _Ft. Ft. to Ft. __Ft. to ' Ft._ Ft. to Ft. Ft. to Ft __Ft. to Ft. .____Ft. to .... F~. Ft. to____Ft MISCL. INFORMATION: DRILLER'S NAME ROBERT C. COWAN. RE. ROBERTA. SHAFER, RE. CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 RECEIVED Municipality of Anchorage SEP 05 2000 DEPARTMENT OF HEALTH AND HUMAN SERVICRS Munic~pahly o! ~ncnorago 825 L Street Dept. Health &Human Semites P.O. Box 196650 'Anchorage, Alaska 99519-6650 The septic inspections for ~e ~eferenced property were performed on ~-~-00 and ~ 29 L~. Prior to submitting the On-site Wastewater Disposal Syste~ and/gr Well Inspection Report we are waiting for the ~-~,~ ~,Fv~ to be completed. ~ If we may be of further service please contact us. Sincerely, 17034 NORTH EAGLE RIVER LOOP · SUffE 204 · EAGLE RNEP~ ALASKA 99577 MUNICIPALITY OF ANCHORAGE Department of Health and Human Sen/ices On-Site Sen/ices Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (gO7) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Renewal Date Issued: Jul 12, 2000 Expiration Date: Jul 12, 2001 Permit Number: SW000226 Legal Description: HUNDRED HILLS ISTADDITION BLK 4 LT 6 Design Engineer: 0003 S & S Engineering Owner Name: Rodney Metcalf Owner Address: 8913 Parkview Terrace Loop Eagle River, AK 99577- Parcel ID: 078-191-09 Site Address: Lot Size: 235010 SQ. FT. Total Bedrooms: 6 Permit Bedrooms: 6 This permit is for the construction of: [] Disposal Field [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage Ail construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18MC72 ) and Drinking Water Regulations ( 18MC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Rick Mystrom. Mayor Municipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 August 25, 1995 Rodney D & Terry L Metcalf 11139 Aurora Circle ~A Eagle River, Alaska 99577 8113 Subject: Lot 6 BLock 4 Hundred Hills 1st Addition Permit ~SW940316, PID #078-191-09 The subject permit, issued August 25, 1994 by this office for a single family well and/or on-site wastewater system, has expired as of August 25, 1995. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as-built inspection report must be sent to this office for review, approval and documentation. All inspection reports must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit; $120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit. If you have any questions, please call this office at 343-4744. r~nS;geP~E' ' On-site Services enc: Copy of Permit cc: S & S Engineering PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW940316 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:OSTDIEK ELDON J OWNER ADDRESS:P.O. BOX 771408 EAGLE RIVER, AK 99577-1408 DATE ISSUED: 8/25/94 EXPIILATION DATE: 8/25/95 PARCEL ID:07819109 LEGAL DESCRIPTION: HUNDRED HILLS 1ST ADDITION BLK 4 LT 6 LOT SIZE: 235010 (SQ. FT.) ~_ NUMBER OF BEDROOMS: ~$/THIS PERMIT: THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 (24 HOURS) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS RECEIVED BY: ROBERT C. COWAN, P.E. ROBERT A. SHAFER, RE. HEALTH AUTHORITY APPROVALS SEWER&WATER MAIN EXTENSIONS SEWER&WATER INSPECTION ENGINEERINGSTUDIES AND REPORTS WELL INSPECTION & ELOWTEST SITE PLANS ROAD DESIGN SOIL TEST PERCOLATION TEST STRUCTURAL & MECHANICAL INSPECTIONS ONSITE WASTEWATER DISPOSAL SYSTEM DESIGN May 24, 1995 CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 MUNICIPALITY OF ANCHORAGE Department of Health and Human Sexvices P.O. Box 196650 Anchorage, AK 99519 REFERENCE: Lot 6; Block 4; Hundred Hills Subdivision Requeet ~ou issue a pe4mit to d~Lfl a well and install a septic system to ~erve the p~opo~e~ ~ix bedroom house o~ the refe~d prope,¢~. A test hole was excavated and a percolation test performed. The, approximate location of the test hole is located on the, attached site plan. The monitoring tube within the test hole. has been checked and found to be d~y. This property has enough area for a future septic upgrade which can be. seen on the attached site plan. We do not anticipate, any adverse, effects on n~ighboring propexties by the installation of the, proposed septic system. This design replaces S & S Engineerin~ design dated 8/9/94 and is to be. installed under permit #SW940316 issued 8/25/94. If you require additional information, please contact us. Sincerely, Robert C. Cowan, P.E. RCC/gk Enclosure 17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577 100' ? / / / / SITE PLAN C) < ~I~ ~o~ Municipality o! Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L' Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: ~O LEGAL DESCRIPTION: [.....~(2~ 2 4 7 8 9 12 14 17 18 19- 20- WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT ~-~,/.~, DEPTH? Depth to Water ./~r Monitoring? ~'~"~ Date: SLOPE SITE PLAN Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE [,-z.~,-'~ (minutest~nch) PERC HOLE DIAMETER TEST RUN BETWEEN ~ FT AND Lc FT COMMENTS $ & S ENGINEERING PERFORMED BY: "¢ *~ ,~a~-','~l. ¢*' ~ ,.I ~ CERTIFY THAT THIS TEST WAS PERFORMED IN I~d3~ =~gle River L~p ~oad ACCORDANCE WITH A~~h~UIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85) Municipality ol Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG w PERCOLATION TEST LEGAL DESCRIPTION:~'c~'r (-~ '~.- ~ t.l,3,3OIZ.r%..~ Township, Range, Section: SLOPE SITE PLAN o~ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15- 16 17 18 19- 20- WAS GROUND WATER \ ENCOUNTERED? ~'~ ~'~ IF YES, AT WHAT DEPTH? Depth lo Water Alter Monitoring?I~ ~ Dale: Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE \'Zp.',~ (mmutes/mch) PERC HOLE DIAMETER TEST RUN BETWEEN %~- FT AND ~" F'r COMMENTS S & $ ENGINEEEING PERFORMED BY: .~. o'xm~'~,~ --~.c'~'la .................. I~;u~, 1__,~3_ ~ l~m~el Nm_ ~ _ .ll'~/,~ W'~ ,3 ~ CERTIFY THAT THIS TEST WAS PERFORMED IN a !~ 7 72-008 (Rev, 4/85) ROBERT C. COWAN, RE. ROBERT A. SHAFER, RE. HEALTH AUTHORITY APPROVALS SEWER&WATER MAIN EXTENSIONS SEWER&WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW TEST SITE PLANS ROAD DESIGN SOIL TEST PERCOLATION TEST STRUCTURAL & MECHANICAL INSPECTIONS ONSITE WASTEWATER DISPOSAL SYSTEM DESIGN ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS CIVIL ENGINEERS (907) 694~2979 FAX (907) 694-1211 REFERENCE: Lot 6, Block 4, Hundred Hills S/D May 24, 1995 GENERAL: The scope of this project includes the installation of a 2000 gallon septic tank and a leachfield trench to serve the proposed six bedroom residence for the referenced property. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. e The contractor shall be responsible for obtaining any necessary underground utility locates. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. On all leachfield mound systems, the property owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded area. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. SEPTIC TANK INSTALLATION: A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. Ail standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 17034 NORTH EAGLE RIVER LOOP . SUITE 204 . EAGLE RIVER, ALASKA 99577 Page Two Lot 6, Block 4, Hundred Hills S/D May 24, 1995 e De Septic tanks installed with less than 4 ft. of cover shall be insulated. A foundation cleanout shall be installed one to four feet from 'the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (ruffed-up) before gravel (sewer rock) placement· e Once 'the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. 3e A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. De Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. Page Three Lot 6, Block 4, Hundred Hills S/D May 24, 1995 MINIMUM MATERIAL SPECIFICATIONS: Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe Perforated Soli~ Cast Iron ASTM D3034 (PVC) ASTM F810 (HDPE) ASTM D2662 (ABS) Yes Yes Yes Yes Yes No Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. Ail leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the %200 sieve. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements. Page Four LOt 6, Block 4, Hundred Hills S/D May 24, 1995 INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of 'the wastewater disposal system. These inspections will occur as follows: The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. e The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-construction meeting will 'take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR/OWNER ROBERT SHAFER, P.E. ROGER SHAFER, P.E. August 03, 1994 CIVIL ENGINEERS (907) 694-2979 FAX 694-1211 HEALTH AUTHORITY APPROVALS SEWER & WATER MAIN EXTENSIONS SEWER & WATER INSPECTION ENGINEERINGSTUDIES ANDREPORTS WELLINSPECTION & FLOW TEST SITE PLANS ROAD DESIGN SOIL TEST PERCOLATION TEST STRUCTURAL & MECHANICAL INSPECTIONS ON SITE WASTE WATER DISPOSAL SYSTEM DESIGN Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES 825 'L' Street P.O. Box 196650 Anchorage, Alaska 99519-6650 REFERENCE: Hundred Hills Subdivision; Block 4; Lot 6 Request you issue a permit to drill a well and install a septic system to serve the proposed three bedroom house on the referenced property. A test hole was excavated and a percolation test performed. The approximate location of the test hole is located on the attached site plan. The monitoring tube within the test hole has been checked and found to be dry. This property has enough area for a future septic upgrade which can be seen on the attached site plan. We do not anticipate any adverse effects on neighboring properties by the installation of the proposed septic system. If you halve an~D2A~questions, or require additional information for your revie~se ~tact us. ~///~/LSU/jk 17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577 o~ oom~ 8 ~ o NYqd 3ils J / / / / / ,OO!, : ,,!, IVlunicipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L' Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST LEGAL DESCRIPTION: t~-r~ L~ ~'~J,~ k~ ~=, SLOPE SITE PLAN WAS GROUND WATER \ ENCOUNTERED? IF YES, AT WHAT L DEPTH? ~ pO E 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O Depth to Waler A~te_.cr. t Reading Date Gross Net Depth to Net Time Time Water Drop PERCOLATION RATE ~--'~,'~ (minutes/inch) PERC HOLE DIAMETER 72-008 (Rev. 4/85) ,' ;: Jv~,r, AlaSKa ' / ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS REFERENCE: Hundred Hills Subdivision #1; Block 4; Lot 6 1. The scope of this project includes the installation of a 1000 gallon septic tank and five foot wide drainfield to serve the proposed three bedroom residence for the referenced property. 2. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The contractor shall be responsible for obtaining any necessary underground utility locates. 4. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. On all leachfield mound systems, the property owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded area. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. SEPTIC TANK INSTALLATION: 1. A septic tank manufacturer. access. is to be constructed by a certified septic tank Construction shall include two 4" cleanouts for pumping 2. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 3. Ail standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 4. Septic tanks installed with less than 4' of cover shall be insulated. Page Two Hundred Hills Subdivision #1; Block 4; Lot 6 August 03, 1994 A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10' from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. 6. Final grading ow~r the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRF/qCH/DR~INFIELD INSTALLATION: Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (roughed-up) before gravel (sewer rock) placement. Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. Monitor tubes shall be of four (4) inch diameter and installed approximately in the locations shown on the design. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. MINIMUM MATERIAL SPECIFICATIONS: 1. Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. Page Three Hundred Hills Subdivision #1; Block 4; Lot 6 August 03, 1994 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). A permeable nontoxic silt barrier (Typar 3401, Mirafi 140/N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. 6. Ail leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with ].ess than 3% passing the #200 sieve. 7. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements. INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. Page Four Hundred Hills Subdivision #1; Block 4; Lot 6 August 03, 1994 3. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required, especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractor's activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractor's activities. Final acceptance of the contractor's work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR/INSTALLER M U Il V CPU �,1 U kl Y O /\ H C H O l! �, J` GF__ �t Development Services Department %Phone- 907-343-7904 On -Site Water & Wastewater Section -- Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 078 191 09 1. GENERAL INFORMATION Expiration Date: moxck L d0 Complete legal description HUNDRED HILLS #1 BLOCK 4 LOT 6 V B46 Location (site addresss) HARP Current property owner(s) METCALF Mailing address Real estate agent 2. TYPE OF DWELLING: R Single Family (w/ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 5 Day phone Day phone 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well El Private Septic IT] Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request tor: N O N E q Distance: Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. Date: COSA Fee $ 550 Waiver Fee $ Date of Payment // ��Z I Receipt Number 072 69.0 COSA# 05C.211 6 & 7 Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm C&M ENGINEERING Phone 8545558 Address 20182 TULWAR Engineer's Printed Name CHARLES BALZARINI Date 11/20/21 6. DSD SIGNATURE ✓ System #1 Approved for °F Al q 49 TH 5 bedrooms System #2 Approved for _ Disapproved Conditional approval for CHARLES G BALZARId bedroomsVIPF CE -13854 r ��lF� pROFE5S14NP�'-� _ bedrooms, with the following stipulations: BY Original Certificate Date: A0/.20.2 J The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Septic System Advisory Well Flow Advisory COSA Checklist blue sheet Nitrate Advisory Arsenic Advisory Other C&� 0UViSor4 X =� WPIER,t ER o o NJ P ` Gh p,M 14 BY Original Certificate Date: A0/.20.2 J The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Septic System Advisory Well Flow Advisory COSA Checklist blue sheet Nitrate Advisory Arsenic Advisory Other C&� 0UViSor4 X COSA Checklist yellow sheet COSA Checklist Legal Description: Parcel ID: If more than 1 septic system on lot: COSA Checklist # of Structure served by this system A. WELL DATA Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date of Sample Comments __________________________________________________________________________________ C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade ft (min) N/A – pressurized field Monitor tubes go to bottom of effective. If not, state depth into effective Code-required soil cover over field System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Adequacy test date Results Pass For bedrooms Fluid depth prior to test in Water added gal New depth in Elapsed time min Final fluid depth in Absorption rate gpd Any rejuvenation treatment (past 12 months) If yes, enter date Comments/Deficiencies: B.TANK DATA Age of tank(s) years Tank type/material6WHHO Measured operating fluid level in septic tank Standpipes/foundation cleanout per record drawing Date of pumping D.ABSORPTION FIELD DATA ______________________ Which system tested (date installed) HUNDRED HILLS #1 BLOCK 4 LOT 6 078 191 09 11 1 +4.5 9/94 - 81 81 +24 C.Balzarini 11/6/21 48 11/10/2021 21 Septic 50 ** Pending, See attachment and comment. trench 2000 11/6/21 5 12.5 25 8 750 36 1440 4.5 24 750 NA 2000 NA Cleanout and MT at start of field were repaired. ✔ COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft From Septic/Holding Tank on Lot to:(Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Property Line > 5’ Yes if No ft Absorption Field > 5’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10’ Yes if No ft Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft If absorption field is under driveway comment below Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft F. ENGINEER’S COMMENTS G. ENGINEER’S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date.11/16/21 ✔✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ The owner has pre-paid ARM services to pump the septic tank once the road conditions are more favorable. The engineer does not expect negative impacts due to delaying the pumping until the roads improve in the spring. ✔ MUNICIPALITY OF ANCHORAGE    DEVELOPMENT SERVICES DEPARTMENT    907‐343‐7904  On‐Site Water and Wastewater Section                                                                                           Fax: 343‐7997  www.muni.org/onsite         Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519‐6650 * www.muni.org      Septic Tank Advisory   Certificate of On‐Site Systems Approval # OSC211687  Subdivision:  Hundred Hills 1st Addition  Block:4, Lot: 6  The septic tank for this property is 21 years old.  The average life for a steel septic  tank is 20 years. Typical replacement costs range from $7,000 to $11,000.   This advisory must be attached to all copies of the subject Certificate of On‐Site  Systems Approval.               This is an example of what the metal of a 30 year old steel tank MAY look like.      ARM Services, LLC 12/2/21 Rodney & Terry Metcalf 654 Harp Circle Eagle River AK 99577 To Whom It may concern ARM Septic Services, LLC has been prepaid for the referenced property above to complete a 2000 gallon septic tank pumping in the spring of 2022. Please call the the ARM office if anyone has any questions regarding scheduling. 
 Thanks so much, 
 Mariah Campbell ARM Septic Services, LLC 907-688-9433 17933 Old Glenn Highway *Chugiak, AK 99567 Ph: (907) 688-9433 Email: ARMServicesAK@outlook.com L�__! Hundred Hills/ Subd. Lot 3 ' N09G5r1'3r1"E X04 00 Lot 4 f ANX®OF A4 \ 1 • • • • • s ; � Q`• I'S �'•• 49 th ! • •�p • o • •moi • • • • • • • s� • g 00 00 00 �. izabeth L. Waiatka •' o s ; 8036 - LS . • „W <N1 AM p�•••••®'pCti�Aw °�ssIOVApX ��. ® V.%NN� T Lot 7 SCALE: 1"= 100' AS-BUILT AS-BUILT NO CORNERS SET THIS DATE I hereby certify that I have performed a Mortgagee's inspection in accordance with ASRLS Standards of the following described property: LOT 6, BLOCK 4, HUNDRED HILLS SUBDIVISION FIRST ADDITION Anchorage Recording Precinct, Alaska, and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Anchorage, Alaska this 2nd day of November , 2021. EASEMENTS OF RECORD, OTHER THAN FRED WALATKA & ASSOCIATES, L.L.C. THOSE SHOWN ON THE RECORDED Engineers and Surveyors FLAT ARE NOT SHOWN HEREON FB 21-6, pg47-48 BE 907-248-1666 g y UNLESS OTHERWISE NOTED. This drawing is a representation of conditions found at the time the mortgage location survey was performed. This document does not constitute a boundary survey and is subject to any inaccuracies that a subsequent boundary survey may disclose. The information contained on this drawing shall not be used to establish any fence. structure or other improvements. This drawing shall only be used for a single property transaction. Use of this drawing by the original client or by others at a later date without the consent of Elizabeth L. Walatka is a violation of Federal Copyright law. Unless gross negligence is discovered, the liability extent of the preparer is limited to the amount of fees collected for services in preparation of this product.