Loading...
HomeMy WebLinkAboutKIMPTON LT 7Kimpton Lot 7 #051-072-70  Municipality o£Anchorage ~:.:', ',% Development Services Department.,~:' '. ~: Building Safety Division On-Site Water and Wastawater Program, 4700 S. Bragaw St.~ P.O. Box 196650 A~chcrage, AK 99519-6650 Page of www.cLanchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. $W010214 PID Number. 051-072-70 Horizon Ventures Wastewater System: [] New [] Upgrade 10900 Corrie Wav. Eaole River. Al( 99[i77 ABSORPTION FIELD LEGAL DESCRIPTION s~ ,,~ 7 Klmpton 1.49 - 1.46 ~,. 1.01-1.02 1.85 - 2.65 F,.102 (51 & 51) Private 221 F,. 221 F~ 580 r~ D3034 & F810 Sullivan 712/2001 152 ~L South Fork Const. 10110/2001 7 Gm unknown F,.I 2 TANK SEPARATION DISTANCES [] septic [] Holding [] S.T.E.P. [] Other.  Septic Abso~tion Lift Holding Public/IWivele Ma~ulac~'e~'; Tank Field Station Tank Sewer U~e Anchorage Tank 1000 c~. wa 100'+ 100'+ NA NA 25'+ Steel 2 *none known BENCH MARK Insulation over tank Door $111 100 Ft Engineer's Stamp Inspections performed by: KND EnRineerin.q Dates: 1~. 10110/2001 :~,,; 4~.~. ~ Development Services Department Approval . o -- ~'~" ......... AS-BUILT SYSTEM DETAILS/SITE PLAN Per-.it SVlOel4 KIMPTBN S/D, LOT 7 PID#051-072-70 , ~ ~CAL[~ 1' = 50' B-G= 58.7''~lT~ TUK~(~ FINAL GRAD[ A-H: 31.~' SCALE, NTS ~ ~ ~ ................. ~. ~ h PREPARED FDR: '"' · MIK[ PARKER EAGLE ~[V[R, AK.  C907) 688-9729 SCALE= NTS ENGINEERING ~ ~~sst°~~ *~ ~[WA~D o,~: ~0/~6/0~ EAGLE RIVER, AK 99577-8736 ~~~ ~ ~: ~ NWl 458 .': v v.v.'.v.'..v.'.-.v.v.v.v.-.-v.-.v.v.v-.'.-.v.-...-..v....v.'.......-....v..'...-... ~:01046.OWG ~: 01046 (907}696-6111/FAX (907}696-8111 Certi[ie rill[ing by SULLIVAN WATER WELLS P.O. BOX r~02T2, CHUGIAK, ALASKA g~5~7 · TELEPHONE 6M.2750 DATE: "//~3//,aae, I T~ IDE~IFICA~ NUMBER: IS well I~at~ at ap~ ~it ~tlon? ~ 'J No ~th~ of ~lli~: ~t~ ~ ~b~ t~l ~pth of ~1: .. ~ing Type .~Wal Diamet~ ~, Il Inches. LinerType: tt~ beJ~ Casing Stickup A~e G~: Stat~t~ ~: /~ ~ R~ ~te: ~ gpm Met~ of T~t~: ~1~ feet , ,. feet Well Intake Opening Type: ~ end r..I open hole ,d Screened: Stat feet Stopped feet GroutTyl~,,~Ro'J'~ ~"~ Volume~ Depth: from ~ feet, to ' 0~. 0"'~ feet Weft Disinfected Upon Completlon? '~s 13 No Method of Disinfectlon: ~ ~W'°~"~/'IF" ~ /~/vr Comments: Ddller's Name ~.~..~,~,..L-.--~ ATFENTION: It Is the responsibility of the property owner to submit a copy of tr~e well lOg to the proper authority. Mu~iclpallty of A~chorage: Department of Health & Human Services and/or Department of Environmental Conservation. MatSu Borough: Oeoartment of Environmental Consewation. MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Progrem 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: Jun 28, 2001 Expiration Date: Jun 28, 2002 Permit Number: SW010214 Legal Description: Kimpton S/D Lot 7 Design Engineer: 0070 KND Engineering Owner Name: Horizon Ventures Owner Address: 10900 Corrie Way Eagle River, AK 99577- Parcel ID: 051-072-70 Site Address: NHN ROAD Lot Size: 51688 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. B. Io-/?-O/ Open and closed on the same day. Covered, sealed, and heated to prevent freezing. Issued By: ~ Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.cLanchorage.ak.us (907) 343-7904 ON-SITE SEWEPJVVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 5-/-- o'~p. -- -70 Permit Number ~W 0/0 Z/~' Property owner(s) H(~rlzon Ventures Mailing address (1 } 10900 ¢orrte Way. Eagle River, AK 99577 Meiti~address (2) /q HM '~o ~ Legal description (Lot, Block & Sub'd.) I(Impten S/D, I-0t ? Legal description (Section, Township & Range) Lot Size 51,687 ~'/b~'~' Acres/Sq. Ft Number of Bedrooms - 'F_~tL.r~ ~ o.~-z,~,~vl J~} ~.~dlDay phone 250-V7~ Z~p Code THIS APPUCATION IS FOR: Sewer Only [] Well Only [] Sewer and Well [] Water Storage [] Sewer Upgrade [] THIS PROPERTY CONTAINS: Hot Tub [] Jacuzzi [] Swimming Pool [] Water Softening Unit [] Therapy Pool [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. Permit Fees: Pate o, Payment: Receipt Number: (Rev. 12/00) Waiver Fees: Date of Payment: Receipt Number: ]K~D ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907) 696-6111/FAX (907) 696-8111 October 10, 2001 Munidpality of Anchorage Development Services Department On-Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Sewer Design Modification - SW010214 - Kimpton, Lot 7 Gentlemen: Per septic system modification discussion and approval with DSD on the date of this letter, please find the attached redesigned septic system. All other items on the previous request will remain the same. If you have any questions~ please contact me at 696-6111/FAX 696-8111. Respectfully submitted, ~I~D Engineering Attachments: Wastewater Absorption System Details/Site Plan WELL 8, WASTEWATER DISPBSAL SYSTEM DETAILS/SITE PLAN KIMPTBN S/D, LOT 7 ~; )\ " ............. Ii: ..,~/ / % ~ ~'-.'"'-'"'~'"""-'- I~,-~¢-~-''''~'- i ~ -'-" --\ / ,_ ..... ........... I I / I i ? .............. ".. DESIGN DETAILS 3 BDRM X 150 GPD = 450 GPO 450 GPD/O.8 GPD PER SO. ET. (6.32 MIN/IN.)-- 56:3 SO. irt (563/5'¢V)) X .88(R0 (l.O' GRAVEL) = 99.1 FrT. TRENCH USE: 2 TRENCHES - 50 (L) X 5' (V) X 1.0'(0) TotoI depth oF system Is 2.5' Crom original grade. m mm, mc ,-'~ct$ VIT.m m~' ~' Totol depth oF' gr'ovet below distribulion pipe Is I.O' . ,.*~,'*~c, s,s,c,, NOTES' e~emca s,mc, [xc£P~ as .mc~. I. USE 1000 GAL. SEPTIC TANK. INSULATE Ir (4' DF' COVER. NE3 SEPTIC: SV$1CN~ WlIHIN L~01T DJ' ~:~. INSULATE TRENCH VITH 2' HO BURIAL FOAM. m)~mCO VCLL [XCCPT As 3. CONTRACTOR VILL ENSURE MINIMUM ~X SLOPE INTO SEPTIC TANK. 4. ADDITIONAL FRILL V[LL ~E ADDED OVER SYSTEM TO MIN. 3' CDVER Ir 5. CDNTRACTDE VILL ENSURE ALL SEPARAT[DNS TO AOJACENT ~~ VELLS & SEPTICS. EAGLE RIVER, AK. 99577 Sc~te: 1'= 100' ........................................ (907) 688-9~9 PAGE ~ SEWARD ~': ~O ENGINEERING *~: SEWARD I~m 9/27/01 EAGLE RIV~R, AK 99577-8736 ---~~ ~ -~ ~ NW~45e [I ',,'.-'....'.-'.-.-.'.'..'.-.-.'.'.-.'.'.'.-.'.'.'".'-'.'.'.'--'.'.'.'.'-.'-...,' ......... '----"..---"--'11 ~mo46.OwG ~" mo,s ~90~6~-~/FAX k,/ASTE~/ATER DISPDSAL SYSTEM DETAILS KIMPTON S/D, LIlT 7 K~ D so TH~20~ TH~200~~ ~' '. · IDgO0 Crl~I£ rAY ('907) 6ee-97,~9 PAGE 2 DF 2 ~~ ~ ~: I ~ NW~ 45e II '-'""'-'-".'.'-'"-'.' '"'"'.'.'-'.'-".'-'.'."-.'.'.'.-'...- .......-..... .............. II ~ '': 01046.OWG ' ~ ~' 01046 (907)696-61 ! I/FAX ~907)696-8111 ~x~D ENGINEERING ~. %... 20441 PTARMIGAN BLVD. · cE 7,,4 SOILS PERCOLATION TEST Peffo~ ~o: Horizon Ventures .Date PerformS: Project:. Kimpton, Lot ? TEST tIOLE # 2001-3 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 14- 16- 17- Depth (Feet) Org - black/red, overburden w/ organics SM/GM- gray, sandy, gravel w/silt and cobbies to 1' mod. dense silt, density, moisture increasing w/depth seeps B.O.H. SEE ATTACHED SITE PLAN FOR HOLE LOCATION Was Ground water encountered? Yes What depth? 12' Depth to water after monitoring? 11.1' Date? 10/12/01 Reading Date Gross Net Depth to Net Time Time Water Drop 1 10/I0/1 1:00 6" - 2 1:30 30 rain 3 8/16" 2 8/16" 3 * 1:31 6" 4 2:01 30 rain 3 6/16" 2 10/16" 5 " 2:02 6' - 6 2:32 30 rain 3 7/16" 2 9/16" · Water Added Percolation Rate 11.71 (m/n/in) Perc Hole Diameter 6" Test Run Between 4 feet and ,5 feet 19- HOLE PRESOAKED 20- PRIOR TO TEST I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. ~D ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)696-6111/FAX (907)696-8111 June 19, 2001 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 · Subject: New sewer & exploratory well permit - Kimpton Lot 7 Gentlemen: The owner has requested we proceed forward to obtain a well and septic permit on the subject lot. On May 4, 2001 we dug one testhole for theproposed system. The results of this test are attached. The general slope of this lot is from east to west at a grade of approximately 4 - 7%. An individual well will serve the lot. We propose to install a 5' wide shallow trench for the proposed 3-bedroom .house. Water was encountered during the excavation at 9' and after monitoring at 8.5. We are requesting an exploratory well permit at this time until we can perform the additional testhole requested. Since we have already performed one testhole with water monitoring within the area of the proposed septic system, we request in lieu of an additional testhole that we be permitted to perform another percolation test at time of construction. There are no public or private wells within 200' of our proposed system location except as noted. There is no surface water within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 696-6111/FAX 696-8111. Respectfully submitted, 1I~I~1~ Engineering Attachments: On-Site Well and Sewer Application Wastewater Absorption System Details/Site Plan Soils Log/Percolation Test WELL K 3 WASTEWATER DISPOSAL KIMPTON S/D, LOT SYSTEM DETAILS/SITE 7 6 PLAN i I DESIGN DETAILS :3 BI]RM X 150 GPO = 450 GPO 450 GPD/O.8 GPO PER SO. IrT. (6,32 MIN/IN.)= 563 SO. IrT ¢563/5'(i/)) X .88(RF) (1.0' GRAVEL) = 99.1 rT. TRENCH USE I TRENCH - 100 (L) X 5' (i/) X Totot depth o? system is P.5° ?rom opiglnG( gp~de. Tot~[ depth o~ g~ve( belo~ dlst¢ibution pipe Is 1.0' . N~TES: !. USE 1000 GAL SEPTIC TANK. INSULATE IF ~. INSULATE TRENCH WITH ~* HD BURIAL rOAM. 3. CONTRACTOR ~ILL ENSURE HINIHUH EZ SLOPE INTO SEPTIC TANK. 4, ADDITIONAL ~]LL ~ILL BE ADDED ~VER SYSTEM T~ ACHIEVE MIN. 3' COVER IF REQUIRED, I 51 CONTRACTOR I/ILL ENSURE ALL SEPARATIONS TO ADJACENT ...... · ~9,ru'~ '"'...: . ~ ...................... I/ELLS & SEPTICS. PREPARED FOR: HIKE PARKER 10900 CORRIE VAY EAGLE RIVER, AK. 99577 (907) 688-9729 SEWARD mu, m: VBG SEWARD ¢~m¢o: KMD SEWARD m,~: 6/1/01 ~ NW1458 01046.DWC ~ ~: 01046 Score: 1'= 100' PAGE I DF 2 ]~ ~ I]~) ENGINEERING ;~0441 PTARMIGAN BLVD, EAGLE RIVER, AK 99577-8736 (9o?)e96-elil/;Ax (9o?)soe-slll WASTEWATER DISPF1SAL SYSTEM DETAILS KIMPTON S/D, LOT 7 ~ ' RBPDSED 1000 GAL THN2 ~ .m. _~ SEPTIC TANK ~I~. ~ __ ~I~. ~% OF A~4~ PREPARED FOR: ........... c907) 6ee-eTe9 PAGE ~ DF ~ 'a~',~ ...... .~ ~ "~ S[WA,O "mm K~D 20441 PTARMIGAN BLVD. .~--~2%'~'2 ..............~."['. ~ ~ SEWARD o*~= 6/I/01 EAGLE RIVER. AK 99577-8736 ~ ~- ~ssto~ ~ [..:......~~..,,.....~.~..~~...........~......~~..~.~~~.~:~....~.~....:...~..~...~,:..~...~.:~.~...,~_ ............] ~~ ~ ~: ~ N~ 458 -- O~ A~. ~ ~ ENG~EE~NG ~/~ ~ ~ .~ ~'~ 2~1 ~A~IGAN BL~ ~~~~?~' ~ EAGLE ~R, AK 995~-~736 ~ SOILS ', Perfo~ed [o~ Horizon Ven[ures Date Perform: 05/~/01 Project: Kimpton, Lot 7 TEST HOLE # 2001-01 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18-- Depth (Feet) Org - black/red, overburden w/ organics, moist GP/GM- gray, sandy, damp gravel w/silt mod. dense GM - gray, sandy-silty gravel, moist, mod. dense silt, density, moisture increasing w/depth seeps B.O.H. SEE ATTACHED SITE PLAN FOR HOLE LOCATION Was Ground water encountered? NO Dep~ to water after monitoring? 8.5' What depth? NA Date? 5/11/01 Reading Date Gross Net Depth to Net Time Time Water Drop 1 5/08/01 1:00 8' 2 1:30 30rain 34/16" 412/16" 3 * 1:31 - 8' 4 2:01' 30 rain 3 4/16" 4 12/16" 5 * 2:02 - 8" 6 2:32 30 rain 3 4/16" 4 12/16" · Water Added 19- 20- HOLE PRESOAKED PRIOR TO TEST IPercolation Rate 6.32 (rain/in) Perc tlole Diameter .. Test Run Between 2 feet and ;~ feet I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. ~,~ 1.~ ENGINEERING ,~:' 20~1 ~A~IGAN BL~, SOILS PERCOLA~ON ~ST Perfo~ fo~ Horizon Ventures De~e Project:. Kimpton, Lot 7 TEST HOLE # 2001-02 Depth (Feet) SEE ATTACHED SITE PLAN I FOR HOLE LOCATION Was Ground water encountered? What depth? NA Depth to water after monitoring? Date? 6/22/01 Reading Date Gross Net Depth to Net Time Time Water Drop 1 6/22/01 3:15 9 4/16" 2 3:45 30 min 4 2/16" 5 2/16" 3 * 3:46 9 4/16" - 4 4:16 30 rain 4 2/16" 5 2/16" 5 * 4:17 9 4/16" - 6 5:47 30 rain 4 2/16' 5 2/16" · Water Added Percolation Rate 5.83 (min/in) Perc Hole Diameter 6' Test Run Between 2 feet and ~ feet 4~ ,% 6- 7- 8- 9- 10- 11- 12- 13- 14- 1,% 16- 17- 18- 19- 20- HOLE PRESOAKED PRIOR TO TEST I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. Municipality of Anchorage Development Services Department Building Safety Division On-Sita Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.cLanchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D.. 051-072-70 Expiration Date: ] -' ! ~/- 0 ~ 1. GENERAL INFORMATION Complete legal description KIMPTON I-OT7 Location (site ~ddress or directions) NHN GLACIER RD., CHUGIAK, AK 99507 Current Property owner(s) Mailing address Lending ag~n, cy HORIZON VENTURES Day phone .688-9729 10900 CORRIE WAY, EAGLE RIVER, AK 99577 Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless othen~ise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: ' Individual Well [] Individual Water Storage I-I Community Class .__ Well [] Public Water System [] TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding tank Community On-site Public Sewer [] [] [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a' pdvate or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a pedod of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(am) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further vedfy that based on the information obtained from the Municipality of Anchorage flies and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(am) tn compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm KND Enqlneerinq Phone. 696-6111 Address, 2044'1 Ptarmiqan Blvd. Eaqle River, AK, 99577 Engineer's PHnted Name Kenneth M. Ouffus Date 10117101 Approved for ~ bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments Attachments: HAA Checklist Septic System Advisory Well Flow Advisory X Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: / 0 ° /'~ -- 0 '/ Municipality of Anchorage Development Services Department Building Safety OMslon On-Site Water & Wastewater Program 4700 South Bragaw 8L P.O. Box 195650 Anchorage, AK 9951g-6650 www.cLanchomge.ak.us (907) 343-7g04 HEALTH AUTHORITY APPROVAL CHECKLIST Parcel ID: 05t.072.70 Klmpton Lot ~ Legal Description: A. WELL DATA Well b'pe I~dvate Date completed 07/02/01 Total depth 221fL If A. B, or C provide PWSID # Sanitary eeal (Y/N)¥ Cased to 221fl` FROM WELL LOG Date of test 07/02/01 StaUo water level t52 Well production WATER 8AMPLE RESULTS: Coliform {I colonies/100 mi. Date of sample: t0/16/0t B. SEPTIC/HOLDING TANK DATA Well Log (Y/N) y Wires ~ protectecl (Y/N) y Casino height (above ground) 2' AT INSPECTION ft. fl` g.p.m g.p.m. Nitrate ~.~4 mgJL Callected by: KND Enalneeflna Other becteda O colonles/10Oml Tank Type/Material An~oraae Tank 18tasl Date installed 10/t0/0t Tank size t000 gal. Number of Compartments L Cleanoute Yas Foundafion cleanout Yea Depression over tank No Hlgh water alarm NA Date of pumping NA.newtank Pumper C. ABsoRpTION FIELD DATA Date installed 10/t0/0t 8oll raUng (g.p.dJfl= or fl=rodrm) U Length 2.3J1Ug2)~ fL Width ~ System type ShaflowTmnch fl` Gravel below pipe 1.02 Depression over field No For L bedrooms gal. · .New depth in. Nosorptlon rate >= If yes, give date Total depth ~ fl. Eft. absorption ama 580 fl= Monitoring tube Yea Date of adequacy test NA. new system Resutte (Pass/Fall) Pass Fluid depth In absorption field before teat In. Water added Elapsed TIme: min. Final fluid depth Any rejuvenation treatment (past 12 mo.) (Y/N & type) In. g.p.d. D. LIFT STATION Date installed N~ 'Pump on" level at __ in. Datum E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 10Q'+ Absorption field on lot 1QQ'+ Public sewer main Sewer/septic sewlce line 25'+ Size in gallons Manhole/Access (Y/N) 'Pump off' level at m in. High water alarm level at Cycles tested Meets almm & circuit requirements? On adjacent lots 1QQ'+ On adjacent lots t00'+ Public sewer manhole/cleanout 1gQ'+ Holdlng tank tQQ'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation ~'+ Property line ~'+ Water main lQ'+ Water sen, ice line tQ'+ Wells on adjacent lots t0Q'e SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line Water Service line Curtain drain F. COMMENTS 10'+ G. ENGINEER'S CERTIFICATION Building foundaUon 10'+ Surface water tQQ'+ Wells on adjacent lots 100'+ I certify that I have determined through field inspections and review of MunicJpe/ records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Pdnted Name Kenneth M. Duffus Date Absorption field ~'+ Surface water 1QO'+ Water main 10'+ D~veway, parking/&mhlcle sterage in. HAA Fee $300 Data of Payment Receipt Number (P~v. 12mo) Waiver Fee $ Data of Payment Receipt Number 0CT-18-01 08:17 FROI/~CT&E ENVIRONMENTAL SRV 9015615301 T-951 P.01/01 F-481 CT&E Environmental Services Inc. Laboratory Division 200 W. Potter Drive Anchorage, AK 99518 Tel: (907) 562-2343 Fax: (907) 561-5301 CT&E Ref. #: Client Name: Project Name: Client Sample ID: Matrix: PWS~D Sample Remarks: 1017190001 KND Engineering n/a Kimpton Lot 7 Drinking Water Client PO~: n/a Printed Date/Time: 10/18/O1 07:45 Collected Date/Time: 10/18/O1 11:30 Received Date/Time: 10/10/01 12:25 Technical Director. Stephen Ede Released Parameter Results PQL Units Total Coliform (MF) 0 co1/100 mi Nitrate 2.24 0.5 mg/L Allowable Prep Analysis Method Limits Date Date Init SM9222B 1 0/18/01 EPA 300 10.0 10/16/01 YAP SCL