HomeMy WebLinkAboutJEFFERS LT 1Jet
r'-5
-t-
I
0 -o /al
, nicipalitYof
Anchorage
825 "L" STREET
ANCHORAGE, ALASKA 99501
(907) 264-4111
GEORGE M, SULLIVAN,
MA YOR
OEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
December 31~ 1980
Ray Jeffers
1507 Martin
Anchorage, Alaska
99504
Permit ~ 800017
Subject: Lot i Block 1 Jeffers Subdivision
A permit issued by this department for well and/or sewer
system has expired as of this date.
Permits are issued on a calendar year basis, as stated on
the permit, by authority of Municipal Ordinance.
If you have drilled the well, a well log should be sent
to this department to.document the installation date.
If an engineer inspected the installation of the on-site
sewer system, please have them send us the as-builts for
our files.
I~ there are any further questions,
office at 264-4720.
Sincerely, ' / /
Les N. BUC.hholz, R.S
Senior Environmental ~F~cialist.
please call this
LNB/ljw
enc: Copy of Permit
SWP/057
,I
PERMIT NO.
· M[JN ! c i .-~AL I T~r° OF ANC~.ORAGE
~DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 'L' STREET, ANCHORAGE, AK. 99501
264-4728
01'-~ ~ TE ~Et4E~ UP~E PE~
~PPLICRNT RAY SEFFERS
.OCRTION RABBIT CREEK
EGRL !LT. 1BLK. 1.JEFFERS!
YPE OF SOIL ABSORPTION SYSTEM IS:
1507 MARTEN
DRAINFIELD
LOT SIZE
3~7 7902
108~00 SQUARE FEET
~AXIMUM NUMBER OF BEDROOMS = ~ SOIL RATING (SC FT?BR)= 175
'HE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS:
~EPTH= 9 LENGTH= ~-e5 GRAVEL DEPTH= 1. 5
THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRIHFIELD.
THE DEPTH OF R TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF .THE
GROUND AND THE BOTTOH OF THE EXCRVRTION (IN FEET).
THE TRENCH WIDTH IS 5. e00 FEET.
THE GRAVEL DEPTH IS THE MINIMUM DEPTH Of GRAVEL BETWEEN THE OUTFRLL PIPE
AND THE BOTTOM OF THE EXCAVATION (IN FEET)·
~EQUIRED SEPTIC TRt~K SIZE= '~ 500 GALLONS
ERMIT RPPLICRNT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE
NSTRLLRTION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE
UMBER OF RESIDENCES THAT THE WELL WILL SERVE.
----- TI~O (2_) I I'-ISPECT I 01'~i5 ARE REQU I RED 7----
RCKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS
EPRRTMENT HILL BE SUBJECT TO PROSECUTION.
IN'IMUM DISTANCE BETWEEN R WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS
00 FEET FOR R PRIVATE WELL OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING
PON THE TYPE OF PUBLIC WELL
THER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAM5 ARE
VRILRBLE TO INSURE PROPER INSTALLATION.
CERTZF~ THAT
: I RM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS A~ SET
OATH BY THE MUNICIPALITY Of ANCHORAGE. ~-
:. I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES.
: I UNDERSTAND THAT THE ON-SITE 5EI~ER SYSTEM MAY REQUIRE ENLARGEMENT IF THE
ESIDENCE IS REMODELED TO INCLUDE HORE THAN 3 BEDROOHS.
SSUED
APPLICANT RAY JEFFERS
V4. 0
825 "t." STREET
ANCHORAGE, ALASKA 99501
(907) 264.4111
SULLIVAN.
December 31, 1979
Ray Jeffers
1507 Marten
Anchorage, Alaska
99504
Permit ~ 790393
Subject: TllN R3W Section 2 SW¼ (Proposed Jeffers Lot 1 Block 1)
A permit issued by this department for well and/or sewer
system has expired.
Permits are issued on a calendar year basis, as stated on
the permit, by authority of Municipal ordinance.
If you have drilled the well, a well log should be sent
to this department to document the installation date.
If an engineer has inspected the installation of the
on-site sewer system, please have them send us the as-builts
for our files.
If there are any further questions, please contact this
office at 264-4720.
.Sincerely,
Les N. Buch. holz, R.S. ..~ ..
Senior Envlronmen=al Speci%~r~.st
LNB/ljw
enc: Copy of Permit
.'Y MUST BE OBTAINED FROM THE FILES - DATA NOT AVAILABLE
HUNI¢IP.4LITY OF Ar~CHG~AGE '"
DEPARTMENT OF HEALTH AND ENYIRONMENTAL PROTECTION
825 'L' STREET, ANCHORRG~ AK.
~N THE COMPUTER
~37 7 ?~.
eNO,N..,=.Ia&M CONSUL'rANTB. INC. lez4 co,~oov^ · .ox ~,o,, · ^~CHO.^GZ. ^L~,, j~U .El.Ii)~ ALITY · '"'OF'~o""e'°'"~ANCHORAGE· ?Lx.
July 17, 1~)7~
Hr. Les Bucholz
Department of Health and Environmental Protection
825 L Street
Fourth Floor West
Anchorage, Alaska 9~$01
DEPT. OF H:ALTH &
ENVIRONMENTAL PROTECTION
JUL 1 ? 1979
RECEI.V. ED
Re: Review of Sanitary Sewer-System, Lot l, Block I, Jeffers Subdivision
Anchorage, Alaska
Dear Mr. Bucholz:
This letter is submitted as a supplement to our report on the subject
property dated June 25, 197~.
After reviewing your recommendations for the sanitary sewer It appears the
system should perform satisfactorily. It was recommended that three trenches
be excavated to ~ feet and backfilled with 2 feet of fissured bedrock
fragments, ~ feet of sand, 1.5 feet of washed aggregate, 0.$ feet of straw
and 3 feet of fill and topsoil. Three leach fields (5' x 35' each) are
to be constructed using the above material.
We hope thls letter meets your present requirements. Should you desire
further Information please do not hesitate to contact us.
Very truly yours,
R&M CONSULTANTS, INC.
I~lchael C. Hartley
Geotechnlcal Engineer
HCH/dJ
July 10, 1~7~
Hr. Les Bucholz
Department of Health and Environmental Protection
825 L Street
Fourth Floor West ~C~_~)~.~t'~%'~,.
Anchorage, Alaska 99501 ~f
Re: Review of Sanitary Sewer S t L (~'('~-~-%'~ ';~ ·
ys em, ot.l,~Block I, vee,ers Subdivision,
Dear Mr. Bucholz: ~
Thls letter is submitted as a supplement to our report on the subject
property dated June 25, 197%
After careful revle~ of yo~deslgn for the sanitary sewer It appears the
system ~ill perform satlsfactorily. This deslgn consisted of excavating
three trenches to g feet and backfllllng ~lth 2 feet of fissured bedrock
fragments, ~ feet of sand, 1.5 feet of ~ashed aggregate, 0.5 feet of stra~
and 3 feet of flll and topsoll. Three leach fields (5~ X 35~ each) are
to be constructed using the above material.
We hope thls letter meets your present requirements. Should you desire
further information please do not hesitate to contact us.
Very truly yours,
R&M CONSULTANTS, INC.
Michael C. Hartley ~/
Geotechnlcal Englneer
MCH/pJ
July 3, 1979
Les Buchholz
Department of Health and Environmental Protection
825 L Street
Fourth Floor West
Anchorage, Alaska 99501
Re: Sanitary Sewer System, Lot 1, Block 1, Jeffers Subdivision,
Anchorage, Alaska
Dear Mr. Buchholz:
This letter is written in response to a request by the Municipality of
Anchorage.
Based on observations at the above referenced site, the fissured bedrock
encountered from 4 to 9 feet should break down into smaller fragments
during excavation. Particle size should range from approximately 2 to
10 inches with some occassionally larger fragments.
hope this letter meets your present requirements. Please contact us
if you have additional questions concerning this letter or if we can be
of additional service.
Very truly yours,
R&M CONSULTANTS, INC.
Michael C. Hartley
Geotechnical Engineer