Loading...
HomeMy WebLinkAboutJEFFERS LT 1Jet r'-5 -t- I 0 -o /al , nicipalitYof Anchorage 825 "L" STREET ANCHORAGE, ALASKA 99501 (907) 264-4111 GEORGE M, SULLIVAN, MA YOR OEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION December 31~ 1980 Ray Jeffers 1507 Martin Anchorage, Alaska 99504 Permit ~ 800017 Subject: Lot i Block 1 Jeffers Subdivision A permit issued by this department for well and/or sewer system has expired as of this date. Permits are issued on a calendar year basis, as stated on the permit, by authority of Municipal Ordinance. If you have drilled the well, a well log should be sent to this department to.document the installation date. If an engineer inspected the installation of the on-site sewer system, please have them send us the as-builts for our files. I~ there are any further questions, office at 264-4720. Sincerely, ' / / Les N. BUC.hholz, R.S Senior Environmental ~F~cialist. please call this LNB/ljw enc: Copy of Permit SWP/057 ,I PERMIT NO. · M[JN ! c i .-~AL I T~r° OF ANC~.ORAGE ~DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 'L' STREET, ANCHORAGE, AK. 99501 264-4728 01'-~ ~ TE ~Et4E~ UP~E PE~ ~PPLICRNT RAY SEFFERS .OCRTION RABBIT CREEK EGRL !LT. 1BLK. 1.JEFFERS! YPE OF SOIL ABSORPTION SYSTEM IS: 1507 MARTEN DRAINFIELD LOT SIZE 3~7 7902 108~00 SQUARE FEET ~AXIMUM NUMBER OF BEDROOMS = ~ SOIL RATING (SC FT?BR)= 175 'HE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: ~EPTH= 9 LENGTH= ~-e5 GRAVEL DEPTH= 1. 5 THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRIHFIELD. THE DEPTH OF R TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF .THE GROUND AND THE BOTTOH OF THE EXCRVRTION (IN FEET). THE TRENCH WIDTH IS 5. e00 FEET. THE GRAVEL DEPTH IS THE MINIMUM DEPTH Of GRAVEL BETWEEN THE OUTFRLL PIPE AND THE BOTTOM OF THE EXCAVATION (IN FEET)· ~EQUIRED SEPTIC TRt~K SIZE= '~ 500 GALLONS ERMIT RPPLICRNT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE NSTRLLRTION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE UMBER OF RESIDENCES THAT THE WELL WILL SERVE. ----- TI~O (2_) I I'-ISPECT I 01'~i5 ARE REQU I RED 7---- RCKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS EPRRTMENT HILL BE SUBJECT TO PROSECUTION. IN'IMUM DISTANCE BETWEEN R WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 00 FEET FOR R PRIVATE WELL OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING PON THE TYPE OF PUBLIC WELL THER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAM5 ARE VRILRBLE TO INSURE PROPER INSTALLATION. CERTZF~ THAT : I RM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS A~ SET OATH BY THE MUNICIPALITY Of ANCHORAGE. ~- :. I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. : I UNDERSTAND THAT THE ON-SITE 5EI~ER SYSTEM MAY REQUIRE ENLARGEMENT IF THE ESIDENCE IS REMODELED TO INCLUDE HORE THAN 3 BEDROOHS. SSUED APPLICANT RAY JEFFERS V4. 0 825 "t." STREET ANCHORAGE, ALASKA 99501 (907) 264.4111 SULLIVAN. December 31, 1979 Ray Jeffers 1507 Marten Anchorage, Alaska 99504 Permit ~ 790393 Subject: TllN R3W Section 2 SW¼ (Proposed Jeffers Lot 1 Block 1) A permit issued by this department for well and/or sewer system has expired. Permits are issued on a calendar year basis, as stated on the permit, by authority of Municipal ordinance. If you have drilled the well, a well log should be sent to this department to document the installation date. If an engineer has inspected the installation of the on-site sewer system, please have them send us the as-builts for our files. If there are any further questions, please contact this office at 264-4720. .Sincerely, Les N. Buch. holz, R.S. ..~ .. Senior Envlronmen=al Speci%~r~.st LNB/ljw enc: Copy of Permit .'Y MUST BE OBTAINED FROM THE FILES - DATA NOT AVAILABLE HUNI¢IP.4LITY OF Ar~CHG~AGE '" DEPARTMENT OF HEALTH AND ENYIRONMENTAL PROTECTION 825 'L' STREET, ANCHORRG~ AK. ~N THE COMPUTER ~37 7 ?~. eNO,N..,=.Ia&M CONSUL'rANTB. INC. lez4 co,~oov^ · .ox ~,o,, · ^~CHO.^GZ. ^L~,, j~U .El.Ii)~ ALITY · '"'OF'~o""e'°'"~ANCHORAGE· ?Lx. July 17, 1~)7~ Hr. Les Bucholz Department of Health and Environmental Protection 825 L Street Fourth Floor West Anchorage, Alaska 9~$01 DEPT. OF H:ALTH & ENVIRONMENTAL PROTECTION JUL 1 ? 1979 RECEI.V. ED Re: Review of Sanitary Sewer-System, Lot l, Block I, Jeffers Subdivision Anchorage, Alaska Dear Mr. Bucholz: This letter is submitted as a supplement to our report on the subject property dated June 25, 197~. After reviewing your recommendations for the sanitary sewer It appears the system should perform satisfactorily. It was recommended that three trenches be excavated to ~ feet and backfilled with 2 feet of fissured bedrock fragments, ~ feet of sand, 1.5 feet of washed aggregate, 0.$ feet of straw and 3 feet of fill and topsoil. Three leach fields (5' x 35' each) are to be constructed using the above material. We hope thls letter meets your present requirements. Should you desire further Information please do not hesitate to contact us. Very truly yours, R&M CONSULTANTS, INC. I~lchael C. Hartley Geotechnlcal Engineer HCH/dJ July 10, 1~7~ Hr. Les Bucholz Department of Health and Environmental Protection 825 L Street Fourth Floor West ~C~_~)~.~t'~%'~,. Anchorage, Alaska 99501 ~f Re: Review of Sanitary Sewer S t L (~'('~-~-%'~ ';~ · ys em, ot.l,~Block I, vee,ers Subdivision, Dear Mr. Bucholz: ~ Thls letter is submitted as a supplement to our report on the subject property dated June 25, 197% After careful revle~ of yo~deslgn for the sanitary sewer It appears the system ~ill perform satlsfactorily. This deslgn consisted of excavating three trenches to g feet and backfllllng ~lth 2 feet of fissured bedrock fragments, ~ feet of sand, 1.5 feet of ~ashed aggregate, 0.5 feet of stra~ and 3 feet of flll and topsoll. Three leach fields (5~ X 35~ each) are to be constructed using the above material. We hope thls letter meets your present requirements. Should you desire further information please do not hesitate to contact us. Very truly yours, R&M CONSULTANTS, INC. Michael C. Hartley ~/ Geotechnlcal Englneer MCH/pJ July 3, 1979 Les Buchholz Department of Health and Environmental Protection 825 L Street Fourth Floor West Anchorage, Alaska 99501 Re: Sanitary Sewer System, Lot 1, Block 1, Jeffers Subdivision, Anchorage, Alaska Dear Mr. Buchholz: This letter is written in response to a request by the Municipality of Anchorage. Based on observations at the above referenced site, the fissured bedrock encountered from 4 to 9 feet should break down into smaller fragments during excavation. Particle size should range from approximately 2 to 10 inches with some occassionally larger fragments. hope this letter meets your present requirements. Please contact us if you have additional questions concerning this letter or if we can be of additional service. Very truly yours, R&M CONSULTANTS, INC. Michael C. Hartley Geotechnical Engineer