ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: 63 ~L-'[- 0 ~ ~ '~ PID Number: 0 ~
Bernard Krueger Wastewater System: ~ New ~ Upgrade
Address:
21950 Judd Circle, Chugiak, Alaska ABSORPTION FIELD
Phone: Number of Bedrooms:
244-8171 3 ~ Deep Trench ~ Shallow Trench ~ Bed ~ Mound ~ Other:
Soil Rating: Total Depth from odginal grade:
LEGAL DESCRIPTION 0.6 GPD/Ft2 7 Ft.
Block: 3 Lot: 25 Subdivision: Depth to pipe boEom from original grade: Gravel depth beneath pipe:
Knik View Estates 3 Ft. 4 Ft.
Township: Range: Section: Fill added above original grade: Gravel Length:
0.9 Ft. 75 Ft.
~ ~ Gravel width: Number of lines: Distance be~een lines:
Well:
New
U
pgrade
5 Ft. 1 N/A Ft.
Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material:
A Ft. Ft. 750 F~ PVC
Driller: Date Drilled: Static Water Level: Installer: Date Installed:
Ft. Dean Construction 10/06/2010
Yield: GPM PumpSetat: Ft. Casing Height Above Ground:
Ft. TANK
SEPARATION DISTANCES D Septic ~ Holding ~ S.T.E.P. ~ Other:
T~ To Septic Absorption Lift Holding ~ublic/Private Manufacturer: Capaci~:
Tank Field Station Tank Sewer Line GaL
Material: Number of Compadments:
weH N/A N/A N/A N/A N/A
Su~aoe Water 100+ ~. 100+ ~. 100+ ff. N/A ~
LIFT
STATION
Size: Manufa~urer:
Lot Line 10+ ff. 10+ ff. 10+ ff. N/A Gal.
"Pump on" level at: "Pump o~' level at: High water alarm at:
Foundation 5 ff. 10+ ff. 10+ ff. N/A in. in. in.
Pump Make & Model Electrical Inspections pe~ormed by:
Cu~ain Drain No,~ ~ ........ ~,, N/A N/A N/A
Remarks:
The tank and li~ station were existing. The only work done was BENCH MARK
Location and Description:
the new leach field. The lot is se~ed by a public well. Threshold on detached garage side door.
Assumed Elevation:
100 Ft.
Inspections pedormed by: Fred Kenley Dates: 1st 10/05/2010
2"d 10/06/2010
Development Se~ices Depa~ment Approval
Conditional Approval Date:~ '~
Reviewed and approved by:
//./
276.83'
X ASPHALT DRIVEWAY
, SWING TIES
,
ITEM ~ DESCRIPTION A
1 FOUNDA~ON CLEANOUT 18.1
2 LINE TO~ARAGE
15.9'
36.3'
52.3'
Lot 23
19.7 5.5.6
.5 TOO-1 ~ 21.0 54.1
4 TOO-2 \ 24.4 55.4
6 LIFT STATIO~I 46.1 67.7
7 FOUNDATION~ CLEANOUT 75.4 50.4
8 EXIST. TREN(~ .~
9 MT-1 71.1 73.2 '
10 MT-2 ~ 84.4 108.5 x
Lot 24
/~SEPT,C // //~SEPTIC
~ AREA,~
-7 205' --~ ----1-15'
143.76'
MT- /
LO
0
Lot 1 2
MT-1
Lot 11
'
/
Lot 12 ~
ARE,
ASBUILT
DOUGLAS T. KENLEY, P.E. c,v,, Eng, ....
9806E. Nor[hstarCi ..... Pal ........ ka99645 . ,,0,,,,6_,0. SITE PLAN
CLIENT: Krueger, Berncrd
L~O^L~ Knik View Estates S/D, Black ,5, Lot 25
...... s:21950 Judd Circle, Chugiok, AK I .......... 051-043-27 I ......... B~,=OSP101208
o
TH-4 /
Lot 25
_\~ 20'
/
/
/ /
/
/
I-"~
Lot 11
r,o ~SSE
AR
CAPPED THREADED BLOWOUT
MONITOR TUBE PIPES ARE
PERFORATED IN SEWER ROCK,
SOLID ABOVE.
FINAL gRADE
1-1/4" DIST. PIPE, TOP--- 99.2
WITH 1/8" HOLES EVERY 24"
5/4-"- 5" DIA. SEWER ROCK
MT-1 = 95.1--
MT-2 = 95.0
102.9
2"
3.9'
4?
WATER TABLE
IMPERMEABLE LAYER
7.9'
BOTTOM OF TEST HOLE EL = 85.7'
VERTICAL DATUM = THRESHOLD OF DETACHED GARAGE DOOR
O_ LEACH FIELD AS-BUILT
NTS
DOUGLAS T. KENLEY, P.E.
9B06E, No~lhstarCircle ·Palmer, Alaska 99645 o (907) 746-1073
CLIENt: Bernard Krueger
AS-BUILT
DRAWINGS
LEOAL: Knik View Estates S/D, Block 5, Lot 25
21950 Judd Circle, Chugiak, AK i 051-045-27
DEPTH
(FEET)
1
ORGANICS
SP SOILS
PERC TEST
B. of H.
SOILS LOG - PERCOLATION TEST
PERC TEST #2
°~:
~i~!~'..:~s,~ ~////,dc.
~..~'..~.~.~.~.~sc SEE ATTACHED SHEETS
FOR SITE DRAW~NOS
DEPTH TO DATE
GROUND WATER
NET TIME WATER LEVEL NET DROP
DATE READING TIME
(MIN.) READING (IN,) (IN.)
10/06/10 1 15:05 8
15:35 30 5 3
2 15:36 8
16:06 30 4-7/8 3-1/8
3 16:07 8
16:37 30 4-7/8 3-1/8
20
PERCOLATION RATE 9.6 (MIN./INCH)
TEST RUN BETWEEN 4.5 FT. AND 5 FT.
PRESOAKED FOR FOUR HOURS YES ~/ NO
PERC. HOLE DIA. 6" (IN.)
COMMENTS:This additional percolation test was required because the trench was moved from
the design submital.
DOUGLAS T. KENLEY, P.E. Civil Engi .... I
9806E. NodhstarCircle ·Palmer, Aleska99645 · (907)746-1073
CLIENT: Bernard Krueger
PERC
TEST
LEC~.: Knik View Estates S/D, Block 3, Lot 25
*DDRESS:21950 dudd Circle, Chugiak, AK
051-043-27 I ~"= NU,~E~: OSP101208
Permit Number:
Tax Code Number:
Work Type:
On-Site Wastewater Disposal System Permit
OSP101208
05104327000
Septic
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Upgrade
Permit Effective Dates: September 30, 2010 to September 30, 2011
Design Engineer: DOUGLAS T KENLEY
Subdivision: KNIK VIEW ESTATES
Site Legal Address: KNIKVIEW ESTATES BLK 3 LT 25 G:1558
Owner/Address: KRUEGER BERNARD & LORRAINE
PO BOX 672535 CHUGIAK AK 995672535
Site Mailing Address: 21950 JUDD ClR, Chugiak
Lot Size in Sq Ft: 46182
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field N SepticTank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Date:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Elmore Road
P.O. Box 196650
Anchorage, Alaska 99507
www.muni.org/onsite
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. O51
Property owner(s)
Mailing address
Site address
Day phone
Zip Code
.Zip Code
Legal description (Sub'd., Block & Lot) /r~/~, x /,¢~,~¢, ~%/~¢/~; ~///2..
Legal description (Township, Range & Section)
Lot Size ,z/_/~, /,¢,2 Sq. Ft. Number of Bedrooms
THIS APPLICATION IS FOR ([~ all that apply,):
Absorption Field
Septic Tank []
Holding Tank []
Privy []
Private Well []
Water Storage []
THIS APPLICATION IS AN:
Initial []
Upgrade [~
Renewal []
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner(et/authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
(Rev, 11/05)
Waiver Fees:
Date of Payment:
Receipt Number:
Douglas T. Kenley, P.E. 9806 E. Northstar Circle, Palmer, Alaska 99645 (907) 746-1073
September 21, 2010
Municipality of Anchorage
On-Site Services
4700 South Bragaw
Anchorage, Alaska
Re: Bernard Kreuger, Owner
Knik View Estates S/D, Block 3, Lot 25
21950 Judd Circle
Chugiak, Alaska
NARRATIVE FOR UPGRADE ON SEPTIC SYSTEM
On Sepember 11,2010, our office attempted to do an adequacy test on the above-mentioned
property, at which time inspection of the monitoring tubes showed 32" of water in one and 33" in
the other. The effective depth of the leach field was 30". This system was in failed condition.
We proceeded to inspect the property for installation of an alternate field. The only area available
required another pressurized system. On September 14th, a test pit was dug to a depth of 17.2', at
which time no water was observed. After the organic layer, it was consistently GM soils. Following
a seven-day monitoring period, water was observed to be at 15' from the surface.
The original gravity system was installed in1999, and in 2000 a replacement system was put in that
required the existing pressurized leach field. The original tank is still in use with normal water level
of 50". Elevation levels were checked to insure there was proper slope from the tank to the lift
station.
The lot is sparsely treed with spruce, birch, and some alders and the area where the leach field will
be installed is relatively level. The house and second garage are located at the back east end of
the triangular lot. The lot slopes steeply to the west from the front of the house to Judd Circle
street.
The area of the lot is 46,182 square feet. The placement of the new system will have no adverse
effect on adjoining lots. All of Knik View Estates Subdivision is on a Class A public well. Bear Park
Subdivision to the east has private wells. See drawings submitted.
If you have any questions, please call me at (907) 746-1073 or 243-5372.
Sincerely,
ouglas T. K
PE #8176
SEPTIC SYSTEM SPECIFICATIONS:
1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE SPECIFICATION IN M.O.A.
WASTEWATER CODE CHAPTER 15.65.060.
2. EXISTING TANK TO BE LEFT IN PLACE & EXISTING LEACH FIELD TO BE ABANDONED
AS PER CODE. NEW 5' WIDE 4-8" E.D. PRESSURIZED LEACH FIELD TO BE LOCATED
AS SHOWN ON SITE PLAN.
5. SERVICE LINE TO DRAIN FIELD SHALL BE 1-1/4" DIA. PVO PIPE.
4-.DRAIN FIELD LINE SHALL BE 1-1/4" DIA. PVO PIPE WITH 1/8" HOLES SPACED
24" APART.
5. PROVIDE 10' MINIMUM SEPARATION BETWEEN EDGE OF TRENCH AND FOUNDATION.
6. PROVIDE 10' MINIMUM SEPARATION BETWEEN SEPTIC SYSTEM AND PROPERTY
LINE.
7. PROVIDE 100' MINIMUM SEPARATION BETWEEN SEPTIC SYSTEM, WELLS &
SURFACE WATER.
DEEP TRENCH CALCULATION:
SOIL TYPE:
PERCOLATION RATE:
APPLICATION RATE (AR):
SILTYY GRAVEL (GM)
USE ,50 MIN. PER INCH. (6" PERC HOLE DIA.)
0.6 GAL./DAY/SF
DESIGN (5) BEDROOMS:
ABSORPTION AREA =
@ 150 GAL. PER BEDROOM = 450 GALLONS
450 GAL/DAY
0.6 GPD/SF = 750 SF
750 SF
TRENCH LENGTH = 5' - 150' x 0.5 = 75'
ASSUMES DOMESTIC WATER USAGE FOR RESIDENTIAL HOME COMSUMPTION.
CALCULATION METHOD OBTAINED FROM MUNICIPALITY OF ANCHORAGE "WASTEWATER
DISPOSAL CODE REGULATION" FEBRUARY 14, 2003; AMC 15.65, TYPICAL WIDE DRAIN
FIELD REQUIREMENTS AND SPECIFICATIONS.
NOTE: FOR APPLICABLE EXCAVATION, TRENCHING, AND SHORING SAFETY
STANDARDS, CONTACT THE STATE OF ALASKA, DEPARTMENT OF LABOR, OCCUPA-
TIONAL SAFETY AND HEALTH OOMLIANCE CONSULTATION, AND TRAINING DIVISION OF
LABOR STANDARDS AND SAFETY AT 269-4955.
DESIGN
DOUGLAS T. KENLEY, P.E. c,v, Eric ....
9806 E. N .............. Pal ................ (907) ....... 3 CALCULATIONS
CLIENT: Bernord Krueger
LEGAL: Knik View Estotes S/D, Block 5, Lo( 25
21950 Judd Circle, Chugiok, AK I*'D"u"SE": 051-045-27 IP~R"'TNu"sER:
..... 9/:o/ o I ........ oTK I ...... rK I ...... N/, I.......... 10117 IBBEET 1 OF 6
~ I i/
I / I /
/ / /,
!
/
Lot 29
Lot 28
~S_SEPTIC
Lot 27 Lot 26 / /
Lot 21
, /__¢sEPT, c
/ ~SEPTIC~ \ AREA~
AREA,/ ',\
/
. -;0"7~ ~ -7 205' .~ 115'
/ Lot 11
/ ,./
Lot 12 /
/ .,/
/ /
/ -
/ /' ~
// ~' ~
/ REBECCA CIRCLE / /I / ~--~-
Lot 2o
%...
Lot 19
/ ~
Lot 14
DOUGLAS T. KENLEY, P.E. civi, Engi .... SITE PLAN
9806E. No~thstarCircle o Palmer, Alaska99645 o (907) 746-1073
CLIENT: Krueger, Bernard
LEOA~: Kinik View Estates S/D, Block .5, Lot 25
^DDRESS:21950 Judd Circle, ChugiGk, AK ]R,D.U~.~: 051--045--27
..... ~/~o/~o I ........ oT~ I ...... ~ I ...... ~.= ~oo,I .......... ~o~1~
2 OF 6
276.83'
143.76'
299.24'
ASPHALT DRIVEWAY
SINGLE
',~ESIDENCE
\
Lot 25
,~SSEPTIC
AREA~
Lot 12
xSX~, ED
Lot 24
~SEPTIC
AREA~
GARAGE
MT-2
/
I TH~
\
\ TH-~
DOUGLAS T. KENLEY, P.E. c,v,, ~,~ ....
Lot 1 1
CLIENT: Krueger, Bernard
LECAL: Knik View Estotes S/D, Block 3, Lot 25
*DDRESS:21950 Judd Circle, Chugiak, AK IP,D"u"SER:051-04,5-27
~SEP
ARE
SITE PLAN
LQ
0
ISHEET 5 OF 6
Lot 12
IT- 1
/
~ 41 '
/
/
/
/
/
I-""----
Lot 1 1
DISCRIPTION OF SYMBOLS ON SITE PLAN
FCO
4" LINE TO 2nd GARAGE
EXISTING 1000 GALLON GREER TANK W/AFTER TANK CO
LIFT STATION W/4" TEE TO ~" PIPE TO BOTTOM OF LIFT TANK
EXISTING 5' WIDE 2.5' ED 72' LONG PRESSURIZED LEACH FIELD
FCO AT 2nd GARAGE
PROPOSED 5' WIDE 4' ED 50' LONG PRESSURIZED LEACH FIELD
Notes:
There is an enclosed dog pen with asphalt floor with access to
the garage. There are no wells within 100' of the dog pen.
The existing leach field has a mound of 2 to 3 feet placed over it
for extra cover.
TH-1 & 2 were dug in 2000, TH-3 on 9/14/2010.
DOUGLAS T. KENLEY, P.E.
9806 E. Northstar Circle o Palmer, Alaska 99645 o (907) 746-1073
CUEN~: Bemord ~<ruecjer
DESIGN
NOTES
LEO^L, Knik View Estotes S/D, Block 5, Lot 25
........ 21950 Judd Circle, Chugiok, AK I .......... 051 -045-27 I .............
MONITOR TUBE PIPES ARE
PERFORATED IN SEWER ROCK,
SOLID ABOVE.
BACKFILL ~'-~,
TRENCH WALL SLOPES WILL VARY
WITH SOIL TYPE AND MUST CONFORM
TO SAFETY STANDARDS, SEE SHEET
1 OF 5
2" DOW RIDGID INSULATION~
REQUIRED IF LESS THAN 56" OF COVER
1-1/4" DIA. WITH 1/8" HOLES EVERY 24"
LAID LEVEL WITH HOLES DOWN.
SIDEWALL OF TRENCH
5/4" - 5" DIA. SEWER ROCK
NOTES:
LENTH OF TRENCH IS~ FEET.
1-1/4" PVC WILL COME FROM EXISTING
PUMP CHAMBER.
PVC LINE FROM EXISTING TRENCH WILL BE
PLUGGED OFF IN THE PUMP CHAMBER.
EXTRA MATERIAL FROM THE JOB WILL BE
USED TO ASSURE THE 3' OF COVER.
5'_+
ORIGINAL GRADE
FABRIC
WATER TABLE
4.2'
IMPERMEABLE LAYER
10.2'
BOTTOM OF TEST HOLE 17.2'
FROM ORIGINAL GRADE
LEACH FIELD PROFILE DESIGN
NTS
DESIGN
DOUGLAS T. KENLEY, P.E. c,vi, En~i ....
.............. C ...... Palmer, Al,skag .... (907) ....... 3 DRAWINGS
CLIENT: Bernard Krueger
LEG^L: Knik View Estotes S/D, Block 5, Lot 25
21950 dudd Circle, Chugiok, AK .u.~: 051-045-27
5 OF 6
DEPTH
(r~E~)
3
5
6
7
ORGANICS
PERC TEST
GM SOILS
GROUND WATER
B. of ri.
SOILS LOG- PERCOLATION TEST
TEST HOLE #1
DEPTH TO DATE
GROUNDWATER
0 9/14/10
15' 9/22/10
SEE ATTACHED SHEETS
FOR SITE DRAWINGS
NET TIME WATER LEVEL NET DROP
DATE READING TIME
(MIN.) READING (IN.) (IN.)
9/14/10 1 15:04 10
~5:54 30 8-1/2 1-1/2
2 15:35 10
16:05 30 8-3/4 1-1/4
3 16:10 10
16:40 30 8-7/8 1-1/8
4 16:41 10
17:11 30 8-7/8 1-1/8
20-
PERCOLATION RATE 30 (MIN./INCH)
TEST RUN BETWEEN 4.5 FT. AND 5 FT.
PRESOAKED FOR FOUR HOURS YES ~ NO
PERC. HOLE DIA. 6" (IN.)
COMMENTS:
SOILS
DOUGLAS T. KENLEY, P.E. Civil Engi ....
)~O~E. North$l~rC ...... Palmer, Alaska99645. <,o,,,,6.,o,, LOG
CLIENT: Bernard Krueger
LEGAL: Knik View Estates S/D, Block 3, Lot 25
ADDRESS:21950 Judd Circle, Chugiek, AK IP'DNUMBE~:051__043__27
IPERMIT NUMBER:
SHEET
6 OF 6
Munici'pality of Anchorage Page , / of
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-SUe Wa,s..l?waler Disposal Syslem and/or Well Inspection Report
Permit Number: ~'~OD C) ~ PID Number: ~ j' ~
""=*: ~t~ ~~ Waslewaler Syslem: D New ~Upgrade
~. ~ ~ ~3=E~ ABSORPTION FIELD
WELL: O New O Upgrade e,.~e~.*mh: ~' r~. /
SEPARATION DISTANCES os,p,, ~.o,d~.~ ~ osz.~.~.
To Seotle A~I~ Lilt ~ ~al Menuleclurer: ~ ~ ~ J /' Capacity In
Well ~1~ ~IU / ~l ~ MaterlM: Numar of Compmtmenls:
Remarks: BENCH ~ARK
-/
Deparlmenl of Heallh ~nd Human Services ~pproval
PERMIT NO. $W980049 PACE 2 Or
Municip. cdi-I: oF
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
p.n. Box ].96(,50 e,..Ancho~'oge0 A..~tosko 99519-6650 · Telephone: 343-4744
ON-SITE WASTEWATER UISPOSAL ~YSTEH AND/OR WELL NSPECT ON REPORT
LECAL LOT 25, BLOCK 3, KNIK VIEW ESTATES S/D P.l.~). NO. 051-043-27
LOT 27 LOT 26
~ ~ ~. SEPTIC TANK r
LOT 24 k ..[~..,z~c.,..o..
..
~ ~ .-'
~ k '~~ ..... ~.:
PER.~flT NO. SW980049
PACE 5 OF 3
Hunicipcti"c of' Anchor'czoe
DEPARTMENT OF HE~[THAND HUHAN SERVICES
ENVIRONHENTAL SERVICES DIVISION
PO Box 196650 OAnchor'~ge, A~kzsko 99519-66500TeJf. phone: 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
LEGAL LOT 25, BLOCK $, KNIK VIEW ESTATES S/D P.I.D. NO. 051--043--27
ST1 ST2 /FINAL GRAD1Eo0.5'
,'.~ EXISTING '1 ~---~1
?,-~ looo GAG I'X.a~'lll
95. SEPTIC I .... III
J
TANK I
~93.3'
FINAL GRADE
A B
FCO 58.5' 14.0'
STI 56.5' 18.0'
ST2 5,5.5' 24.0'
DBL1 52.5' 26.0'
DBL2 51.5' 28.0'
VNT 49.0' 3.5,5'
MH 47.0' 36.5'
MT1 65.5' 90.5'
MT2 66.0' 89.0'
2" INSULATION ~,~
MT1 = 97.9' [__~
MT2 = 97,9'
/
MT1 = 102.5'
MT2 = 102.5'
-DIST. PIPE = 100.4'
WATER FOUND @ 93.4' .~,
DISTRIBUTION DATA: 89.9' B.O.H.
PUMP=15 GPM
1 LATERAL 70' LONG (1-1/4"P)
15 3/16"P HOLES/LATERAL SPACED 4' O.C.
E N C_[~LF~~ STAMP
/'2'..
, . :. ~ .......~?,~'.s,~.~ ~.'. ~. ~-_.
BAILEY EL.F.~*iRK~
PO BOX '7T1304
EAGLE RIVER AK ~
PROPOSAL SUBMITTED TO:
c~, ~
PHONE ~.
PROPOSAL
WORK 1'O BE PERFORMED AT:
~ , - , by u~ If nol ~cc;e~)ted within ' day~i
MUNICIPADTY OF ANCHORAGE
Department of Health and Human Services
On-Site Services Program
825 L Street, Room 502
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-4744
ON-SITE WASTEWA?ER DISPOSAL SYSTEM PERMIT
Upgrade
Date Issued: Aug 02, 2000
Expiration Date: Aug 02, 2001
Permit Number:. SW000277
Legal Description: KNIK VIEW ESTATES BLK
Design Engineer:. 0825 Robert Shafer, PE
Owner Name: Bernie Kreuger
Owner Address: PO Sox 672535
Chugiak, AK 99567-
3LT 25
Parcel ID: 051-043-27
Site Address: 021950 JUDD ClR
Lot Size: 46182 SQ. FT.
Total Bedrooms: 0 Permit Bedrooms:
This permit is for the construction of:
[] Disposal Field [] SepticTank [] Holding Tank [] Privy
[] Private Well [] Water Storage
Ail construction must be in accordance with:
1. The attached approved design.
2. Ail requirements specified in Anchorage Municipal Code Chaptem 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each Inspection. Provide notification by calling
(907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either:. A. Open and dosed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
WIDE DRAINFIELD SHALL BE LENGTHENED TO 72 FEET LONG
Received By:
Issued By:
July 31, 2000
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
P.O. Box 196650
Anchorage, AK. 99519
REFERENCE: Lot 25, Block 3, Knik View Estates
It is requested that you issue a permit to install a septic system to serve the existing
three bedroom dwelling on the referenced property.
A test hole was excavated and a pemolation test was performed. The approximate location
of the test hole is located on the attached site plan. At the time of excavation 6/30/00 water
was found at 11 feet, after ground water monitoring, water was found at 8.5 feet.
We do not anticipate any adverse effects on neighboring wells, septic systems, reserve
areas or drainage patterns by the installation of the proposed septic system. The
construction of iNs system will not prevent any future development on any of the adjacent
properties.
Ifyou require additional information, please contact us.
inclosure
LOT 27 LOT 26 ~EA~~.~
~..~rA /I... ,,/....~a~...L-;... - .,,. ~ ~
A~PHALT ~RIV[WAy [XI~TING ~0~ GALLON
~ SEPTIC TANK~I ~ % ~ ~ ., · .-
[XISTING
uu'r~ ~ ~ · ~u.~.s,.~ ~ ~ SITE PLAN / DESIGN
3 BEORO0~ = 450 GPO X [oc,~o.-- ~ DATE: 7/31/00
SOILS = ~PD/SOUARE FOOT~
~~ITERIA:
'~E~,.,~, .... , ~ CHECKED BY: R.A.S.
5'WIDE ~ ~ . ~oo'wm,~,us . SCALE: 1" = 60'
Pu~P=15o,, ~
Municipality of Anchorage.
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR:
LEGAL DESCRIPTION:
4' I C 'f"
5'
6'
7
8 '1~ .O~
10 /~ ~...
11
12 --'~'~,~.
13-
14-
15.
16-
17-
18-
19-
20-
DATEPERFORME
~1 ig.-- d[~4.~ Township, Range. Section:
sLoPE
WAS GROUND WATER
ENCOUNTERED?
IF YES. AT WHAT
MortiSing? ~' *~
SITE PLAN
Gross Net Depth to Net
Reading Date Time Time Water Drop
r~-I~.~ ~_ ~
I
PERCOLATION RATE '/~:~ (mmutes.,~nch) PERC HOLE DIAMETER'
TEST RUN BETWEEN ~ ...,.,,.~D '~' '~ FT
· - f DATE:
72-008 (Rev, 4/85)
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MATERIAL SPECIFICATIONS
REFERENCE: Lot 25, Block 3, Knik View Estates
July 3 i, 2000
GENERAL:
The scope of this project includes the installation of a pmssmized five foot wide
drainfield and a pump basin to serve the existing three bedroom residence located on
the referenced property.
Construction shall be in accordance with the approved site plan and design drawings,
Municipal permit with any special provisions or conditions, and all applicable State
and Municipal Wastewater Disposal Regulations.
The contractor shall be responsible for obtaining any necessary underground utility
locates.
Unless specifically agreed otherwise, the property owner shall be responsible for final
grading areas subsequently depressed from soil settling.
Contractors installing wastewater disposal systems must be certified by the Municipal
Health Department for system installations. Owners installing their own systems must
also receive prior approval from the Municipal Health Department.
ABSORPTION TRENCII/DRAINFIELD INSTALLATION:
Excavate the proposed trench to the dimensions shown on the design. The bottom of
the excavation shall be within 2 inches of level. If the sidewalls of the excavation
become smeared, they must be raked or scratched (rafted-up) before gravel (sewer
rock) placement.
Once the gravel is installed, the distribution pipe is to be installed level with the holes
faced downward. The distribution piping is to be ofPVC (ASTM D3034 or equal).
AIl joints are to be solvent cemented. Gravel is then to be placed over the distribution
pipe to provide a minimum of 2 inches of cover over the pipe.
A silt barrier must be installed between the final gravel layer and the native soil
backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill.
Page 2
Lot 25, Block 3, Knik View Estates
du~/31,200O
4. Monitor tubes shall be of four (4) inch diameter, installed approximately in the
locations shown on the design, and extend a minimum of 12 inches above final grade.
The portion of the monitoring tube extending through the gravel shall be perforated
from the bottom of the trench to the invert of the distribution pipe. This is equivalent
to the effective depth of the gravel as noted on the design.
Backfill over the final gravel layer must not be less than twenty-four (24) inches.
Insulation must be installed when the backfill depth is less than thirty-six (36) inches.
The finish grade over the U'ench must be mounded to prevent the formation of a
depression after settling.
MINIMUM MATERIAL SPECIFICATIONS:
Any septic tank proposed for installation must be constructed by a Municipally
approved septic tank manufacturer.
The following pipe materials are approved for use in septic system installations in the
Municipality of Anchorage:
Type of Pirie Perforated Solid
Cast Iron Yes Yes
ASTM D3034 (PVC) Yes Yes
ASTM F810 (HDPE) Yes No
ASTM D2662 (ABS) Yes Yes
Use of a type of pipe other than listed above must be approved by the inspecting
engineer.
Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical
Company Styrofoam HI or equal).
Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco,
or equal).
A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be
installed between the final leachfield gravel layer and the native soil backfill.
All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3%
passing the #200 sieve.
Page 3
Lot 25, Block 3, Knik View Estates
July 3t. 2000
7. When sand is being used as a filter material, its gradation specifications must conform to
current M.O.A. or D.E.C. requirements, which ever specifications applies.
INSPECTIONS:
Typically there will be a minimum of three (3) inspections required during the installation of
the wastewater disposal system. These inspections will occur as follows:
The first inspection must be conducted after the excavation of ditches, pits,
trenches, or beds and before the installation of any gravel. A septic tank may
be set in place, but may not be backfilled before this inspection.
The second inspection must be conducted after the placement of the silt baMer,
gravel, distribution lines, standpipes, cleanouts, and insulation, but before the
placement of any other backfill.
3. The final inspection is to occur upon final grading of the property.
Often there will be more lhan these 3 inspections required. Especially with the installation of
multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting
engineer is to be contacted at least 24 hours prior lo the start of construction. If necessary, a
pre-construction meeting will take place on-site. The inspecting engineer will not coordinate,
direct or control in any way the contractors activities.
The owner shall contract with the contractor to perform the work outlined in these
specifications and plans and in accordance with the attached M.O.A. permit. There will be no
contractual arrangement existing between the contractor and S & S Engineering. S & S
Engineering shall be the owner's representative and will inspect the work as stated above to
document the contractors activities. Final acceptance of the contractors work rests with the
owner and the M.O.A.
S & S Engineering shall have no liability tO the owner or to others for acts or omissions oflhe
contractor or any other persons performing work on this project or the failure of the contractor
to carry out the work in accordance with these construction documents. S & S Engineering's
inspecting engineer will not be responsible for the construction means, methods, techniques,
sequence, procedures or the safety precautions incident to this project.
CONTRACTOR / INSTALLER
~.,..08/21/2B00 07:12 9076881123 I<RUE:GERCO ~ PAGE 01
To: On-Site Services
Fax: 343-4786
Ph #: 343-4744
From: Bernard Krueger
Krueger Contracting
Fax: 688-1123
Ph #: 688-2633
Pages: ONE
I am a licensed general contractor well versed in the use of machinery and
mechanics of on-site waste water disposal systems. This letter is to notify you
that I will be installing my own septic field as per permit # SW00277. Thank you
for your time in this mattcr.
Sincerely,
21950 Judd Circle (physical address)
P.O. Box 672535 (mailing address)
Chugiak, Alaska 99567
· '° Municipality of Anchorage Page
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater DiSposal System and/or Well Inspection Report
Permit Number: ~'["~ C~ ~¢~)0 L.~ ~ PID Number: 0~1~ ~ ~
Name: ~/~ , ~y~O, ;~ ~r H~ ~ ~~ Wastewater System: ~New ~ Upgrade
~&~ ~¢~/Ip,q ~f,v~ e,~7 ABSORPTION FIELD
Phone:~-~.~'~ INo. of Bedrooms:~ ~DeepTrench ~ Shallow Trench OBed ~Mound ~Other
LEGAL DESCRIPTION SoilRating: 0' ~ GPD/Sq. Ft. Total Depth from orlginal grade: ~
Lot: ~5' Block: ~K. ,~ Vig¢ ~Subdiv~ion:. · ~ Depth to pipe bottomfrom odgi algrade:~ Ft Grave depth ben7 PiP~ Ft.
Township: J Range: J Sectiom Fill ad d e d a ~(~al. g~d e: Ft. Gravel length: ~'~¢ ~ Ft.
WELL: g New D Upgra Gravelwidth: ~ Ft. '" Ft.
Total D . Cased TO: Total absorption area~ P'pe m t rial:
Classification ,Private. A.B,C):, ~' r, ~t. Ft. O0 SQ. Ft. ~S~ P~
Ft.
Yield: ~ [ ~m¢~t:Pump Set at: Ft. I Casing Height Above Ground:Ft. TAN K
~ SEPARATION DISTANCES ~Septic O Holding O S.T.E.P.
Man factur r: ~ ~ Capacity in gallons:
To Septic Absorption Lift Holding Public/Private ~
From Tank Fie~d Station Ta~k Sewer Lines ~ ~
W~te~ ~'~ ~O~¢ LIFT STATION
L~ ~, ~, Size in gallons: [Manufacturer: ~
"Pump on" level ~~' level at: I High water alarm at:
FoundationS' 17' ~el Electrical Inspections performed by:
Remarks: BENCH. MARK
Location and Desoriptiom g~ ~ O~
AssumedElevati°n: I O0
Inspections pedormed b?7O34 ~agle River Leog ~oad No. ~ates: 1st ~//3J ~ ~ ~ ~~
Eagle River, AlasEa 9~577 2nd ~/~o/9 ¢ ~t ,O~T C. COWA,
Department of Health and Human ~e~ces approva~ ~, 4¢., .... ...,
Reviewed and approved by~_,~ /~,~Date: ~-~-~ .
72-013 (Rev. 9/91 ) MOA 25
P~;RMI? NO SW980049 PAG~ 2 OF 5
i~umiciDo.[.i~: o~ Amchor'o,~e
B.E?ARTMENT OF HEA~TH SERV~
ANN HUMAN CES
ENVIRONMENTAL SERVICES ~OVOS~ON
P.8, Box i96650 ~A~chopQge, A~d~R~ 995~9-6650~Te~ephone: 343-4744
ON=SoTE WASTEWATER DISPOSAL SYSTE~ AND/OR WELL ONSPECTOON REPORT
L~GAL LOT 25, BLOCK 5, KNIK VIEW ESTATES S/D P.I.D. NO. 051--045--27
LET 27 LE]T 26
DRIVEWAY
NEW 1000 GAL,
LET
L~T
~:.-.g.~.~,,~ ..........
PERMIT NO SW980049 PAGE 3 OF 3
HuniciDaLit; of' Anchor'o. oe
DEPARTMENT OF HEALTHAND HUM'AN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.B, Box t96650 IAnchor'age, At6sk~ 995tg-6650~T~(~hone: 343-4744
ON-S~TE WASTEWATER DISPOSAL SYSTEH AND/OR WELL iNSPECTION REPORT
LEGAL LOT 25, BLOCK 3, KNIK VIEW ESTATES S/D P.I.D. NO. 051--043--27'
ST1
ST2 /FINAL
99.6'
NEW
.000 GAL
SEPTIC
TANK
GRADE
A B
FCO 58.5' 1 4.0'
ST1 56.5' 1 8.0'
ST2 55.5' 24.0'
DBL1 52.5' 26.0'
DBL2 51.5' 28.0'
CO1 49.0' 33.5'
MT1 47.0' 56.5'
C02 65.5' 90.5'
MT2 66.0' 89.0'
FINAL GRADE~k~
NT1 = 89.4'
HT8 89,5'
CB1 =
CB8
CO1
CB2
·
NO WATER FOUND
83.4' B.0.H.
99,5'
100.8'
94,1'
94,3'
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
PAGE
1 OF 1 ~
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW980049
DESIGN ENGINEER:S & S ENGINEERING
OWNER NAME:KRUEGER BERNARD & LORRAINE
OWNER ADDRESS:22568 CENTURION DRIVE
CHUGIAK, AK 99567
DATE ISSUED: 4/01/98
EXPIRATION DATE: 4/01/99
PARCEL ID:05104327
LEGAL DESCRIPTION:
KNIK VIEW ESTATES BLK
3 LT 25
LOT SIZE: 46182 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
DATE:
ROBERT C. COWAN, P.E.
March 11, 1998
CIVIL ENGINEERS
(907) 694-2979
FAX (907) 694-1211
SEWER & WATER
INSPECTION
ENGINEERING STUDIES
AND REFORTS
WELL INSPECTION
& FLOWTEST
ROADOESIGN
SOILTEST
PERCOLATION
TEST
STRUCTURAL&
MECHANICAL
INSPECTIONS
ONSITE
W&STEWATER
DISPOSAL SYSTEM
DESIGN
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
P.O. Box 196650
Anchorage, AK. 99519
REFERENCE: Lot 25, Block 3, Knik View Estates S/D
Request you issue a permit to install a septic system to serve the proposed three
bedroom house on thc referenced property.
A test hole was excavated and a percolation test was performed. The approximate
location of the test hole is located on the attached site plan.
At the time of excavation no groundwater was encountered and after seven day
groundwater monitoring, the test hole was found to be dry.
This property has enough area for a future septic upgrade which can be seen on the
attached site plan.
We do not anticipate any adverse effects on neighboring wells, septic systems or
drainage patterns by the installation of the proposed septic system.
If you require additional information, please contact us.
Sincerely,
RCC6
Enclosure
17034 NORTH EAGLE RIVER LOOP SUITE 204 · EAGLE RIVER, ALASKA 99577
-1" = 60'
SCALE
SITE PLAN
DESIGN
~C
PERFORMED FOR:
8
9
10
11-
12-
13-
14-
15
16-
17-
18-
19-
20-
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES ?~('~
825 "L" Street, Anchorage Alaska 99502-0650
'.~ ' ,,..,
~1~ ~~ DATE PERFORMED:
Township, Range, Section:
1
2
3
4
5
6
7
~-~-r~-r~.~ SLOPE SITE PLAN
WAS GROUND WATER
ENCOUNTERED?
S
L
IF YES, AT WHAT / O
DEPTH? p
E
Dep(h to Water Aftee
Monitoring? h4,2
Dale: ¢/0/18
Gross Net Depth to Net
Reading Date Time Time Water Drop
PERCOLATION RATE J~ (minutes/inch) PERC HOLE DIAMETER
'lEST RUN BETWEEN ~ FT AND ~ FT
COMMENTS
72-008 (Rev. 4/85}
ROBERT C. COWAN, P.E,
SEWER&WATER
INSPECTION
ENGINEERING STUDIES
ANO REPORTS
WELL INSPECTION
&I:LOWTEST
ROA~DESIGN
SOILTEST
PERCOLATION
TEST
STRUCTURAL&
MECHANICAL
INSPECTIONS
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MATERIAL SPECIFICATIONS
CIVIL ENGINEERS
(907) 694-2979
FAX (907) 694-1211
REFERENCE: Lot 25, Block 3, Knik View Estates S/D
March 11, 1998
GENERAL:
The scope of this project includes the installation of a 1000 gallon septic tank
and a five foot wide drainfield to serve the proposed three bedroom residence or
the referenced property.
Construction shall be in accordance with the approved site plan and design
drawings, Municipal permit with any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal Regulations.
The contractor shall be responsible for obtaining any necessary underground
utility locates.
Unless specifically agreed otherwise, the property owner shall be responsible for
final grading areas subsequently depressed from soil settling. On all leachfield
mound systems, the property owner shall be responsible for ensuring a
satisfactory vegetation growth over the mounded area.
Contractors installing wastewater disposal systems must be certified by the
Municipal Health Department for system installations. Owners installing their
own systems must also receive prior approval from the Municipal Health
Department.
SEPTIC TANK INSTALLATION:
A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" cleanouts for pumping access.
The septic tank shall be sufficiently bedded to prevent settling or shifting of the
tank.
All standpipes on the septic tank shall extend a minimum of I2 inches above
final grade.
17034 NORTH EAGLE RIVER LOOP SUITE 204 " EAGLE RIVER, ALASKA 99577
Page Two
Lot 25, Block 3, Knik View Estates S/D
March 11, 1998
4. Septic tanks installed with less than 4 ft. of cover shall be insulated.
A foundation cleanout shall be installed one to four feet fi:om the building foundation.
In the line between the tank and the leachfield them shall be two adjacent cleanouts
(unless an effluent pumping system exists within the septic tank). These cleanouts shall
be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in
line, shall be to clean toward the leachfield. The second cleanout shall be to clean
toward the septic tank.
Final grading over the septic tank shall be such that a positive slope exists away from
the septic tank.
ABSORPTION TRENCH/DRAINFIELD INSTALLATION:
Excavate the proposed trench to the dimensions shown on the design. The bottom of
the excavation shall be within 2 inches of level. If the sidewalls of the excavation
become smeared, they must be raked or scratched (ruffed-up) before gravel (sewer rock)
placement.
Once the gravel is installed, the distribution pipe is to be installed level with the
perforations faced downward. Gravel is then to be placed over the distribution pipe to
provide a minimum of 2 inches of cover over the pipe.
A silt barrier must be installed between the final gravel layer and the native soil backfill.
Ensure the silt barrier covers the entire gravel surface before placing backfill.
Monitor tubes shall be of four (4) inch diameter, installed approximately in the
locations shown on the design, and extend a minimum of 12 inches above final grade.
The portion of the monitoring tube extending through the gravel shall be perforated
fi:om the bottom of the trench to the invert of the distribution pipe. This is equivalent to
the effective depth of the gravel as noted on the design.
Backfill over the fmal gravel layer must not be less than twenty-four (24) inches.
Insulation must be installed when the backfill depth is less than thirty-six (36) inches.
The finish grade over the trench must be mounded to prevent the formation of a
depression after settling.
MINIMUM MATERIAL SPECIFICATIONS:
1. Any septic tank proposed for installation must be constructed by a Municipally
approved septic tank manufacturer.
Page Three
Lot 25, Block 3, Knik View Estates S/D
March 11, 1998
The following pipe materials are approved for use in septic system installations in the
Municipality of Anchorage:
Type of Pipe Perforated Solid
Cast Iron Yes Yes
ASTM D3034 (PVC) Yes Yes
ASTM F810 (HDPE) Yes No
ASTM D2662 (ABS) Yes Yes
Use of a type of pipe other than listed above must be approved by the inspecting
engineer.
Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical
Company Styrofoam HI or equal).
Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco,
or equal).
A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed
between the final leachfield gravel layer and the native soil backfill.
All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3%
passing the #200 sieve.
When sand is being used as a filter material, its gradation specifications must conform
to current M.O.A. or D.E.C. requirements, which ever applies.
INSPECTIONS:
Typically there will be a minimum of three (3) inspections required during the installation of
the wastewater disposal system. These inspections will occur as follows:
The first inspection must be conducted after the excavation of ditches, pits,
trenches, or beds and before the installation of any gravel. A septic tank may be
set in place, but may not be backfilled before this inspection.
The second inspection must be conducted after the placement of the silt barrier,
gravel, distribution lines, standpipes, eleanouts, and insulation, but before the
placement of any other backfill.
3. The final inspection is to occur upon final grading of the property.
Page Four
Lot 25, Block 3, Knik View Estates S/D
March 11, 1998
Often there will be more than these 3 inspections required. Especially with the installation of
multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting
engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a
pre-construction meeting will take place on-site. The inspecting engineer will not coordinate,
direct or control in any way the contractors activities.
The owner shall contract with the contractor to perform the work outlined in these
specifications and plans and in accordance with the attached M.O.A. permit. There will be no
contractual arrangement existing between the contractor and S & S Engineering. S & S
Engineering shall be the owner's representative and will inspect the work as stated above to
document the contractors activities. Final acceptance of the contractors work rests with the
owner and the M.O.A.
S & S Engineering shall have no liability to the owner or to others for acts or omissions of the
contractor or any other persons performing work on this project or the failure of the contractor
to carry out the work in accordance with these construction documents. S & S Engineering's
inspecting engineer will not be responsible for the construction means, methods, techniques,
sequence, procedures or the safety precautions incident to this project.