HomeMy WebLinkAboutLILAC PARK BLK 1 LT 5Lielac Park
Block 1
Lot 5
EXPIRED
#015-211-20
Alunicipahty of Anchorage
George I: ll'uerch, Dlayor
Building Safer' Div4slon
P.O. Box IM650 • 4700 S. Braga w Street
Anchontge, Alaslui t)< M9-6650 • (SM) 34:3$301
6/7/2001 hllp://ai%ic.cl.nnchontge.nk.us
Stephen Routh
6231 Petrified Tree Cir.
Anchorage AK
Subject: Expired On -Site Water and/or Wastewater Permit.
Permit Number: SW000018,
Parcel ID: #015-211-20
Dear Stephen Routh:
Department of
Public NVorks
An On -Site Water/Wastewater Permit, number SW000018, issued by this office for a
single-family system, expired on Feb 17, 2001. This permit was valid for 365 calendar
days.
If this was a well permit and the well has been drilled, a well log must be sent to this
office for documentation of the installation and to close the permit.
If this permit was for a wastewater disposal system, an original as -built inspection report
must be sent to this office for review, approval and documentation. This as -built
inspection report must be signed by the licensed Professional Engineer who inspected the
installation of the system. As -built inspection reports are required to be submitted within
30 days of the completion of the system.
If no system was installed under this permit, and you are still planning to install a well or
wastewater disposal system, a new permit must be obtained from this office. When
applying for a new permit, the fees are: $320.00 for a wastewater permit and $120.00 for
a well permit.
If you have any questions, please call this office at 343-7904.
Sincerely,
(Letters Sent 6/7/01 without copies being made, second printing for file copies)
James Cross, PE
Manager
On -Site Water and Wastewater Program
enc: Copy of permit
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On -Site Services Program
825 L Street, Room 502
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 3434744
f ►1SFr:f'MW
li51ODe 1*"
ala81av ra����
C�
4ImIUo�
ONSITE WASTEWATER DISPOSAL SYSTEM /WATER SUPPLY PER�JM/�R� // ( /� n/y�
Initial Datd 1XIOFe
Dtr'18 /2000 r
Permit Number: SW000018
Legal Description: LILAC PARK BLK 1 LT 5
Expiration Date: Feb 17, 2001
Parcel ID: 015-211-20
Design Engineer: 0069 Douglas T. Kenley, PE Site Address: 012200 LILAC DR
Owner Name: Stephen Routh Lot Size: 137118 SQ. FT.
Owner Address: 6231 Petrified Tree Cir. Total Bedrooms: 8 Permit Bedrooms: 8
Anchorage . AK 99516 -
This permit is for the construction of:
R✓ Disposal Field F✓ Septic Tank ❑ Holding Tank ❑ Privy Private Well Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
THE SEPTIC TANK SHALL BE A SINGLE TANK WITH A MINIMUM CAPACITY OF 3000 GALLONS.
o K' D t -o
t N A- z,&oo
3A -t- t 4 tJK
�_A S�
`{
, f Jo 10 o g A-�_
r4nAll< . 8 "
tO
g S
Nei L£ CL4,�
,
Received By:
Issued By:
Date: 2 2 2
Lo
Date: Z —16 —6)0
MUNICIPALITY OF ANCHORAGE
Department of Health & Human Services
On -Site Sewer/Well Permit Application
NOTE: Application must be Reed out comptetely SINGLE FAMILY DWELLING Parcel ldenb6calan Number
Property Owner Name `����`r.�EJ �o1X7_W Day Phone Jill— i99#9
Mailing Address
Legal Description
r�
Zip Code 9f*'6
7 / S�dan Townsn p _
Lot Size _;F, 7/ / / Acres g Ft y Inspections will be conducted by: Vim__
Number of Bedrooms: B '� Approved Engineering Firm
Municipality (permit fee included)
Does your house contain any of the following: Hot Tub, Swimming Pool, Therapy Pool, Jacuzzi,
or Water Softener Unit? %s If yes, which one? ✓'�� `�'`'' �C
This application is for. Sewer Only Sewer and Well '� Sewer Upgrade Well Only -
1 certify that the above Information is correct. I further certify that this application is being made for a Single Family Dwelling
and in accordance with applicable Municipal codes.
Fees:
72-012 Mee 10/861
Proppeeny, Owner I Drifter
Receipt ff e7��"` `
/t'ermit tt swOOOL)/eg
Douglas T. Kenley, P.E. 9960 E. Puffin Drive. Palmer. Alaska 99645 (907)74&7073
PERCOLATION TEST RESULTS
AND
GENERAL SITE INVESTIGATION REPORT
for
Lot 5, Block 1, Lilac Park Subdivision
Anchorage, Alaska
Mr. Stephen D. Routh, Owner
RECEIVED
FEB 14 20
MUNICIPAUTY OF AN0110RAGE
NIRONMENTAL SERVICES DIVIS'
On January 5, 2000, the above -referenced 3.71 acre site was inspected to determine its
adequacy for supporting an on-site water and wastewater disposal system. Soil test pits
and percolation tests were performed and are being submitted under an application to the
Health and Human Service, On -Site Services Department for the installation of on-site
services.
The site is located on Lilac Drive off Huffman Road. Approximately 2/3 of the parcel is
approximately at the same elevation as Lilac Drive. Near the west end, the parcel slopes
down towards the west approximately 18 feet to a lower bench. The immediate area that
has been selected for the wastewater disposal system is at the bottom of this bench and
has an average cross slope of 2 to 4%. The site is moderately treed with birch, spruce and
alders.
On-site observation and physical survey show that there are no water wells nor private
wastewater disposal systems within a 100' radius of the proposed system. No surface
water was observed at the time of the inspection, and it appears that there is no potential
for contamination of adjacent water wells or streams.
On January 8-10, 2000, five test holes were dug to average depths of 18 feet. Percolation
tests were performed in all five test pits to determine the adequacy of subsurface soils to
accommodate both the primary and replacement on-site wastewater disposal systems.
The results of these tests are attached to this report.
The test site had adequate percolation rate to support the proposed eight bedroom
residence. Subsurface soils were found to be silty -gravel with sand overlain by 16" of
surface organics. Percolation rates for the soil was found to average approximately 30
minutes per inch.
The proposed system will have no measurable impact on reserve space, surface or
subsurface, or on drainage to adjacent lots.
Please consider this report as a request for review and approval of the attached design
drawings for an on-site wastewater disposal system and water well.
Lot 5, Block 1, Lilac Park Subdivision
Page -2-
If there should be any questions concerning the percolation rate or characteristics of the
site, please call me at (907) 746-1073 or 243-5372.
Sincerely,
Douglas T. Kenley,
PE#8176
RECEIVED
FEB 14 2000
MUNICIPALITY OF ANCHORAGE
NIRONMENTAL SERVICES DIVIS'
ED
I
I
I
I
S 89'58'10" W — 220:00'
/ 10' Y{LECO— t ELECTRIC CASEMENT — — — — — —
----------------�----------------------- -----
WELL
GO I
RAOIU� b I ;
/
T—,�P
SHENANDOAH MLLS SUBDIW•TH #3
,
o
9
�\ r"rl—� /) j
100.0' WELL RADIUS
ITEM
SCRIPTION
1Q
EXISTING FION CLEAN-OUT
20
NEW ,,SOD SEPTIC TANK
3Q
NEW DOUBLN-OUT
®
TYPIGaL LINNOUT (, 00' O.C.)NEW
4" DRNEW
ZT
DIVERSVENEW
2' W .D. XLAB' LONG TRENCHNEW
MONITOTYPICAL
TREEANOUTPROPOSED
1
F�FWELL RADIUS
GNO'
�9
r l l 4
2 2
a
10
/( R SIIOTE
�NC
PROPOSED 8- EDROOM� -Q
RESIDE CE
!J I
I
100.0' WE
I .
RPD
I .0 µELL ID$ -
I
1/
��,:�
V
_ ABSORPTION SYSTEM PL/AN �DESIGN) LET
� ESyi.
;o
I
FOU
NDATI(
CLEANOUT
SEPTIC SYSTEM SPECIFICATIONS:
1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE
LATEST EDITION OF THE HEALTH AND HUMAN SERVICES
CONSTRUCTION SPECIFICATIONS FOR DEEP TRENCHES
(SEE ATTACHED).
2. NEW SEPTIC TANK SHALL BE OF STEEL CONSTRUCTION BY
AN MOA APPROVED MANUFACTURER WITH WATER TIGHT
COUPLERS ON INLET AND OUTLET.
3. SERVICE
PIPE. DRAIN
SL PE SERVICELINESHALL BDIAMETER EI/4PERFOOT MN
SOLIDMUM.
4. DRAIN FIELD LINES SHALL BE 4" DIA. PERFORATED PIPE.
INSTALL PIPES LEVEL WITH PERFORATION HOLES DOWN.
5. PROVIDE 5 FT MINIMUM SEPARATION BETWEEN EDGE OF
TANK AND FOUNDATION.
BOTTOM OF TEST HOLE
18' BELOW EXISTING GRADE
STANDARD DEEP TRENCH LENGTH CALCULATION:
SOIL TYPE: SILTY GRAVEL WITH SAND a INSTALL BOTH A PRIMARY AND SECONDARY TRENCH.
PERCOLATION RATE: 15 MIN. PER INCH. AVERAGE (6" PERC HOLE DIA.) - INSTALL A ZOBEL DIVERTER VALVE BETWEEN THE PRIMARY AND SECONDARY TRENCHES
APPLICATION RATE (AR): 0.80 PD/SF REQUIRED BY (TABLE 1, AO 90-48)
APPLICATION RATE (AR): USED 0.60 GPD/SF FOR CONSERVATISM ,ASSUMES DOMESTIC WATER USAGE FOR RESIDENTIAL HOME CONSUMPTION.
CALCULATION METHOD OBTAINED FROM MUNICIPALITY P ANCHORAGE "WASTEWATER
DESIGN 8) BEDROOMS: DISPOSAL REGULATION" SEPTEMBER 18, 1990: CHAPTER 15.65.060
( ®150 GAL. PER BEDROOM = 1,200 GALLONS NOTE: FOR APPLICABLE EXCAVATION, TRENCHING, AND SHORING SAFETY
ABSORPTION AREA = 1,200 GAL-AAR) STANDARDS, CONTACT THE STATE OF ALASKA, DEPARTMENT OF LABOR, OCCUPA-
0.60 GPD SF = 2,000 SF TIONAL SAFETY AND HEALTH COMLIANCE CONSULTATION, AND TRAINING DIVISION P
LABOR STANDARDS AND SAFETY AT 264-2599 OR 264-2597.
LENGTH OF TRENCH = 2,000 SF
2 X 90 SIDEWALLS = 112 FEET
tON4
9M,.11, 9K ...,
ROUTH RE8D0JCE - LLAC DRRtE
LOT 6, BLOCK 1 LLAC PARK SUBDIVISION
YHT ymm 0
SEPTIC SYSTEM LAYOUT C2
IIIPIRT AW 99103 0�4 R6 1 «oi
OF 2
TWO-WAY CLEANOUT
TANK CLEANOUT, TYP,
TANK CLEANOUT, TYP,
ZOBEL DIVERTER
VALVE
MONITOR TUBE - CAPPED
FINAL GRADE
PIPE IS PERFORATED IN SEWER ROCK,
SOLID ABOVE.
EXISTING GRADE
BACKFILL
%/\
\%/\
TRENCH WALL SLOPES WILL VARY
MUST
S STA DARD—S
TO SAFETY SHEEND
T
3' MIN,
NOTE BELOW.
FILTER FABRIC
2" DOW RIDGID INSULATION
2" 6"
REQUIRED IF LESS THAN 36" OF COVER
oo
oo 12' MIN.
4" DIA. PERFORATED PIPE
LAID LEVEL WITH HOLES DOWN.
NEW 1,500 GAL.
NEW 1,500 GAL.
SIDEWALL OF TRENCH
STEEL SEPTIC TANK
STEEL SEPTIC TANK
3/4" - 3" DIA. SEWER ROCK
9'-0"
2'-0"118'-0"
MIN. o
WIDTH
4'-0" MIN.
ABSORPTION SYSTEM
O
SECTION
(DES_ IGN)
BAKH
UCKETS
SECONDARY
TRENCH
NTS
6'-0'
PRIMARY TRENCH
WATER TABLE
-..--------- - ----2'-0" MIN.
SEPTIC SYSTEM SPECIFICATIONS:
1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE
LATEST EDITION OF THE HEALTH AND HUMAN SERVICES
CONSTRUCTION SPECIFICATIONS FOR DEEP TRENCHES
(SEE ATTACHED).
2. NEW SEPTIC TANK SHALL BE OF STEEL CONSTRUCTION BY
AN MOA APPROVED MANUFACTURER WITH WATER TIGHT
COUPLERS ON INLET AND OUTLET.
3. SERVICE
PIPE. DRAIN
SL PE SERVICELINESHALL BDIAMETER EI/4PERFOOT MN
SOLIDMUM.
4. DRAIN FIELD LINES SHALL BE 4" DIA. PERFORATED PIPE.
INSTALL PIPES LEVEL WITH PERFORATION HOLES DOWN.
5. PROVIDE 5 FT MINIMUM SEPARATION BETWEEN EDGE OF
TANK AND FOUNDATION.
BOTTOM OF TEST HOLE
18' BELOW EXISTING GRADE
STANDARD DEEP TRENCH LENGTH CALCULATION:
SOIL TYPE: SILTY GRAVEL WITH SAND a INSTALL BOTH A PRIMARY AND SECONDARY TRENCH.
PERCOLATION RATE: 15 MIN. PER INCH. AVERAGE (6" PERC HOLE DIA.) - INSTALL A ZOBEL DIVERTER VALVE BETWEEN THE PRIMARY AND SECONDARY TRENCHES
APPLICATION RATE (AR): 0.80 PD/SF REQUIRED BY (TABLE 1, AO 90-48)
APPLICATION RATE (AR): USED 0.60 GPD/SF FOR CONSERVATISM ,ASSUMES DOMESTIC WATER USAGE FOR RESIDENTIAL HOME CONSUMPTION.
CALCULATION METHOD OBTAINED FROM MUNICIPALITY P ANCHORAGE "WASTEWATER
DESIGN 8) BEDROOMS: DISPOSAL REGULATION" SEPTEMBER 18, 1990: CHAPTER 15.65.060
( ®150 GAL. PER BEDROOM = 1,200 GALLONS NOTE: FOR APPLICABLE EXCAVATION, TRENCHING, AND SHORING SAFETY
ABSORPTION AREA = 1,200 GAL-AAR) STANDARDS, CONTACT THE STATE OF ALASKA, DEPARTMENT OF LABOR, OCCUPA-
0.60 GPD SF = 2,000 SF TIONAL SAFETY AND HEALTH COMLIANCE CONSULTATION, AND TRAINING DIVISION P
LABOR STANDARDS AND SAFETY AT 264-2599 OR 264-2597.
LENGTH OF TRENCH = 2,000 SF
2 X 90 SIDEWALLS = 112 FEET
tON4
9M,.11, 9K ...,
ROUTH RE8D0JCE - LLAC DRRtE
LOT 6, BLOCK 1 LLAC PARK SUBDIVISION
YHT ymm 0
SEPTIC SYSTEM LAYOUT C2
IIIPIRT AW 99103 0�4 R6 1 «oi
OF 2
.t
e Municipality of Anchorage ^^ nn ,9f
DEPARTMENT OF HEALTH & HUMAN SERVICES �* ' `�l'` TH • • '
825 "L" Street. Anchorage. Alaska 99502-0650 .'
SOILS LOG — PERCOLATION TEST /• • • • • i
/ 9;. COU .S . K'cN
PERFORMED FOR: Jr!'EO/iGiJ L,. 'e ds—i,/ DATE PERFORME� ••• '� '•
LEGAL DESCRIPTION: LoTs �K L L.,,oc 0/PE�.t—' Township, Range, Section:
SLOPE SITE PLAN
(FEET) I OvtA.ti�G6
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
WASGROUNDWATER �c
�.4 nlQY S/LTy ENCOUNTERED?
Geo�6� S
L
Z!r o. All
IF YES, AT WHAT ..� 0
DEPTH? P
E
Depth to Waer A r
Monitoring? oJ—� 031e:y5z
Reading
Date
GrossNet
Time Time
Depth to
Water
Net
Drop
izA
4-
.70
9 ,.
..
2
i.
01
201�2
!/
..Xy
20 y l 6
IL—ll PERCOLATION RATE //3(mmutevtncn) PERC HOLE DIAMETER o
TESTRUNBETWEEN 'i/Z FTAND � FT
COMMENTS 1�.�ESO.O,c/EO t.�O.i1/1•"Y�.� T(.tISfALGEO I
PERFORMED BY: �'�-""�'s-IG6y I
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT A THIS DATE.
72-008 Rev. 41851
f IFY THAT THIS TEST WAS PERFORMED IN
2.11 .00
Municipality of Anchorage
e ` DEPARTMENT OF HEALTH Q HUMAN SERVICES
825 "L' Street. Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
PERFORMED FOR. .>7zp/,/6.e� .�cy7-�V DATE PERFORMED:-`_X�,`��a""" -
LEGAL DESCRIPTION LeT �B<fcrt�� L/G42 7✓/.G;ownshi 5 ROPEge. SECIIOn: SITE PLAN
DEPTH
IF ET)
1 O.QGA/t9/G S
2
3-
4-
5-
6-
7-
8-
9-
10•
11 -
12
13
14
15
16
17
18
19
a
SANOy $.� WAS GROUND WATER 4D,
' / ENCOUNTERED?
45;/e_A4ILrL—
Agre.
IF YES, AT WHAT
DEPTH?
Depth to Wrier Aee /
Moailatioa) '�o'�F' 011e:// 00
Reading Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
97
90
,7
20 1 I PERCOLATION RATE Immutevmch) PERC HOLE DIAMETER
u TEST RUN BETWEEN FT AND FT
COMMENTS %yrPidOA�L�.0/Tiy//r',O,(%/TOL S /rt.IStf1�-c—EO
�lSEG �..f6Al4-Ey I J
PERFORMED BY
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN
72008 IRev 4/85)
CERTIFY THAT THIS TEST WAS PERFORMED IN
THIS DATE ATE. Z' ( ��
TH
Municipality of Anchorage , , ...
e " DEPARTMENT OF HEALTH S HUMAN SERVICES .
825 "L" Street, Anchorage, Alaska 99502-0650 •9 : �' . KEf%'
SOILS LOG — PERCOLATION TEST l��a CE 8176
PERFORMED FOR.
,JfC�</6'n.l Ae'o uY// DATE PERFORMED -'Ll; X;;t=- ""
LEGAL DESCRIPTION Lor�B<et.� L���-S���Township. Range. Section.SLOPE SITE PLAN
N
WAS GROUND WATER
ENCOUNTERED? °
IF YES. AT WHAT
DEPTH?
Depth W Water Aller
.ria.✓` — Dale: /
i
L
a
E
Reading Date
Grott
Time
Net
Time
Depth to
Water
Net
Drop
f
6"
20U PERCOLATION RATE ',44Immutevmeh) PERO OL
DIAMETER
TEST RUN BETWEEN FT AND 6 FT
COMMENTS �.tE.SO,O,�EO stJi Ti.� �O.✓�>O Tc/O'EI .JST/iGGcC�c
n
PERFORMED BY. F"Zer-0 LLQ �1 JU4�
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECTleA THIS DATE
72-0081Re,r 4/851
IFY THAT THIS TEST WAS PERFORMED IN
2 ' Iq'tb
OF,_At �1-_
Municipality of Anchorage• • • • ••
a ti DEPARTMENT OF HEALTH & HUMAN SERVICES J.
825 "L" Street, Anchorage, Alaska 99502-0650 y'I` ...
kNtJr7.:
SOILS LOG - PERCOLATION TEST ��,CE 8176
PERFORMED FOR:-��`P�`%�iV Q, Qd�JJ's� DATE PERFORMEO..�_jXX�+V�TOU
LEGAL DESCRIPTION: Lof SuO�Township. Range, Section:
C1 nPC SITE PLAN
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1E
li
1f
1f
S,a.JOY.Sicly �,e.4lJEL
WAS GROUND WATER NO
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
Depth to Water Atlel
Monitoring? c"J'r Date:
ONO
Reading Date
Gross Net
Time Time
Depth to
Water
Net
Drop
.r
CID
—
Reading Date
Gross Net
Time Time
Depth to
Water
Net
Drop
.r
CID
—
O
20 I I PERCOLATION RATE 'z49 Immutew,nCh) PERC HOLE DIAMETER G"
u TEST RUN BETWEEN 45%: FT AND F' FT
COMMENTS
PERFORMED BY. �'�""' JCG.✓GF' �/ I —
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN
72-0081Rev 4/85)
ERTIFY THAT 1q.60
THIIS TEST WAS PERFORMED IN
THIS DATE E, LI . dy
a V Municipality of Anchorage
DEPARTMENT OF HEALTH 8 HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
PERFORMED FOR. ✓�YGOi,/E'.t-1 O, �Oc�TiJ DATE PE
LEGAL DESCRIPTION Township, Range, Section:
�1 SLOPE SITE PLAN
1
2
3
4
5
6
7
6
9
10
11
12
13
14
15
16
17
16
Q,eGAN�G S
J.o.Joy .�icry li•�.vtJEL
0
WAS GROUND WATER A
ENCOUNTERED?y
IF YES, AT WHAT
DEPTH?
Depth to wren Atler
klonitoring? �e'JE One. o0
■■■■■■■■■■
19
20
PERCOLATION RATE �Z/�/�d Iminulevmcnl PERC HOLE DIAMETER
TESTRUNBETWEEN XlZ FTAND 6 FT
COMMENTS a�.Qb.S0�4.t�Ei1 G(..✓iriAzf /A.ZiY/i7lGG��%♦ T.rr.laor.+ovr_/�'O
PERFORMED BY. ��''� ^' �Cs1'`IRift h2qgkCERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFEdl ON THIS DAV DATE. 7.( .(:)o
72-008 (Re.. 41851
MUNICIPALITY OF ANCHORAGE
MEMORANDUM
DATE:
TO:
FROM:
October 26, 1988
File; Lots 4&5 Blk.1 Lilac Park z~~
D.N. Bolles, On-site Services
SUBJECT: Imported fill.
A site visit by D.N. Bolles and S.E. Oswalt, on this date,
revealed that almost all the available area on both the subject
lots had been covered with imported fill material. The
thickness of the fill varies, however, the eastern extremity
would seem to exceed 15' in depth. This fill material contains
trees and other organic materials, thus rendering it
unacceptable for use by on-site waste water disposal systems.
Another concern is that the native organic mat may not have been
removed and thus act as a conduit for surface and ground water.
Also the storm drain platted along the back of Lots 1 and 2
along the side of Lot 3, discharges through a CMP to the north.
This pipe crosses Lot 3 and may cross over portions of Lots 4
and 5 as well.
Until these items can be taken care of the subject lots cannot
receive approval for on-site well or septic. The storm drain
must be platted and an easement granted~ also no septic system
may be allowed within 100' up slope or 30' down slope of the
storm drain. The fill area must be probed and the content and
depth determined.