Development Services Department
Building Safety Division
On-Site Water end Wastewaler Program, 4700 S. Bragaw SI.
P.O. Box ~96650 Anchorage, AK 99519-6650 Page J o! 3
www.cLanchorage.ak.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: 5 L~O[O O ~[~' PID Number:
"'"" ~.,O/'~g ~Jt~/v~to?A WastewaterSystem: I~New I'~Uograde
~[~'~o¥ ~0(~'0'7 ,~nt~;~"' ¢~¢~'~-~7 7 ABSORPTION FIELD
Well: ~ New ~ Upgrade ~.~ ~
SEPARATION DISTANCES ~sep~]c D .o~d~.g D S.T.E.P. D Othe~
To Septic Absorptior [~ floldingPub~batc
"~" BENCH MARK
' tOO ,,
........... 37034 Eagle Rl~r Leap ~e~ ~ 1~~
Develbpme~t Services Department Approval
'~ -~.>. ..... ,..~-? ~
Reviewed and approved b ~ ~9ate: J O '~'
PERMIT NO SWO10023 PAGE 2 OF 5
Municipotit.. _y_..oF' .A.n_c h.o F g g.e.
DEPARTMENT OF HEALTH ANI) HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 IAmcho~oe, Al~sko 99519-66501 Telephor~e~ 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL iNSPECTION REPORT
t~GA~, LOT 53, BLOCK 2, WILL1AMSON #2
LOT
P.I.D, NO.
/
LOT 31
/
-~ /
SEPTICt
LOT
\
SEPTiC~ ~..
~,,,,,TA N K cm
&
NEW
1250
SEPTIC TANK
5
DRIVEWAY
015-074-25
/
/
/
/
/
/
/
/
/
k
\
\
\
\
\
\
\
\
\
\
\
\
\
\ \\
\
IdT2 \
x.
ROBERT c.
CE- 8801
PERMIT NO SW010025 PAGE 5 OP 3
Municip. o[it_y__oF .A.n_c h.o.r' g g.e.
DEPARTMENT OF HEALTHAND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
p.n. Box 196650 eAnchom~ge, Al~skr~ 99519-6650®Telephone~ 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
LEGAL LOT 53, BLOCK 2, WILLIAMSON #2
P.I.U. NO. 015--074--23
ST1
FINAL GRADE/
NEW 1250
GALLON
SEPTIC TANK
ST~,...~ 98.6'
FINAL GRADE
MT1 =85.7'
MT2=85.7'
col =9"L8'
02=100.4'
·
NO WATER FOUND
79.7' B.O.H.
A B C
FCO - 31.0' 7.5'
ST1 - 34.5' 11.5'
ST2 50.0' 42.5' -
DBL1 48.0' 45.5' -
OBL2 46.5' 46.0' -
CO1 68.0' 55.0' -
MT1 65.5' 55.5' -
C02 1 6.0' - $9.0'
MT2 18.5' - 36.0'
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Sire Wafer & Wastewater Program
4700 South Bragaw Streef
P,O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Date Issued: Feb 20, 2001
Expiration Date: Feb 20, 2002
Permit Number: SW010023 Parcel ID: 015-074-23
Legal Description:r~'VILLIAMO0N #2 SUBDIVISION BLOCK '2:[.OT 3.3f
Design Engineer: 0003 S & S Engineering Site Address: 5022 EAST 98TH AVENUE
Owner Name: GEORGE WlLMOTH Lot Size: 13664 SQ. FT.
Owner Address: PO BOX 201707 Total Bedrooms: 4 Permit Bedrooms: 4
ANCHORAGE, AK 99520-1707
This permit Is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well [] Water Storage
Afl construction must be in accordance with:
1, The attached approved design.
2. Afl requirements specified In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Afaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Issued By:
Date: ~ - ~-o-O !
Date:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWEPJVVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parce, 0 / 7 4 - Z 3
Permit Number SWOlO0 Z,~
Propertyowner(s) _~6~0/"~'~ ,J;I ~,.o'rl~ Dayphone
Mailingaddress(1) PO BC~x :[01707/ ,'~l~/'l~onn_~.~.~ ~ ~20-1707
Mailing address (2)~O22
Legal description (Lot, Block & Sub'd.)
Legal description (Section, Township & Range)
Lot Size
THIS APPLICATION IS//FOR:
Sewer Only
Sewer and Well
Sewer Upgrade
THIS PROPERTY CONTAINS:
Hot Tub
Swimming Pool
Therapy Pool
Zip Code ~'~',.5"/~
;
Number of Bedrooms
Well Only
Water Storage
Jacuzzi
Water Softening Unit
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
./~__~.~ S & $ ENGINEERING
(Signature of property owner or authorized agent) F.~ Rhm~, AJ~m ~577
Permit Fees:
Date of Payment:
Receipt Number:
(Rev. 12/00)
Waiver Fees:
Date of Payment:
Receipt Number:
ROBERT C. COWAN, P.E.
February 13, 2001
CML ENGINEErtS
(907) 694-2979
FAX (907) 694-1211
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
P.O. Box 196650
Anchorage, AK. 99519
REFERENCE: Lot 33, Block 2, Williamson #2
It Is requested that you issue a permit to install a septic system to serve the proposed
fourbedroomdwellingonthereferencedproperty. -rt4¢ rao,~4 a,~ ~,~
A test hole was excavated, and a percolation test performed. The approximate location of
the test hole is located on the attached site plan. At the time ofexcavation, 6/24/92, water
was not found. After ground water monitoring, the tube was dry.
We do not anticipate any adverse effects on neighboring wells, septic systems, reserve
areas or drainage patterns by the installation of the proposed septic system. The
construction of this system will not prevent any future development on any of the adjacent
properties.
If you require additional information, please contact us.
Sincerely,
Robert C. Cowan, P.E.
RCC/bjj
Enclosure
17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, AL,'~ KA 99577
-~~ ~'" I.OT 33, BLOCK 2, WIi. I,IAMSON #2I
O.O.J. R.C.C. 2-13-01 I OF 1
trin~ DESIGN CRI).'ERIA: ~o.,,,~,o,,~,,oo,,~o,o .. · ,- . - ~ .
4 BDEM = 600 '~D /
SOILS = 0.6 CPI/SO.FT. [ WORK.
........ ~ ~ J PROPERTIES SERVED BY
8.~ EFFECTIVE L'~- ~ I COMMUNITY WATER
Z
~~ 2.~ 'l WIDE ~ cro
~ ~ ~LONO ~', / C~K~ I ', SERV[D ar C~SS 'A'
I / .... ~ / ~. , I WATER SYSTEM
OOUBLE
Z
~ ~ ~ VELOPE
Municipality o! Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street. Anchorage. Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR: ~---~'/
LEGAL DESCRIPTION:
1
4-
5-
6
7
8
9
10
11
12
14-
15-
16-
17-
18
19-
20-
~ ~'~O: · ....~'~,~
DATE
Township, Range, Section:
SLOPE SITE PLAN
WASGROUNDWATER
ENCOUNTERED?
S
L
IF YES, AT WHAT O
DEPTH? p
E
Oepth to Water After
Monitoring? "~'~ Dale: ~7-1-'~Z'
Dross Net Depth to Net
Reading Dete Time Time Water Drop
PERCOLATION RATE ~ {'~ (m~nutes/mch} PERC HOLE DIAMETER
TEST RUN BETWEEN "~ FTAND ~--~ FT
COMMENTS
PERFORMED BY: S & S ENGINEERING I rr"-~ ~[--~
17034 Ea fe River Leo Roa
ACCORDANCE WITH A~[/~[3~a~I'c~;~'JI~E~L~I~ EFFECT ON }HIS DATE.
72~ (Rev.
CERTIFY THAT THIS TEST WAS PERFORMED IN
DATE: '7-- I 'Z---
ROBERT C. COWAN. P.E.
CML ENGINEEF{S
(907) 694-2979
FAX (907) 694.1211
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MATERIAL SPECIFICATIONS
REFERENCE: Lot 33, Block 2, Williamson/12
February 13, 2001
GENERAL:
The scope of this project includes the installation of a 1250 gallon minimum
septic tank and a new trench to serve the proposed four bedroom residence
located on the referenced property.
Construction shall be in accordance with the approved site plan and design
drawings, Municipal permit with any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal Regulations.
The contractor shall be responsible for obtaining any necessary underground
utility locates.
Unless specifically agreed otherwise, the property owner shall be responsible
for final grading areas subsequently depressed from soil settling.
Contractors installing wastewater disposal systems must be certified by the
Municipal Health Department for system installations. Owners installing
their own systems must also receive prior approval from the Municipal ttealth
Department.
SEPTIC TANK INSTALLATION:
I. A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" clcanouts for pumping access.
2. The septic tank shall be sufficiently bedded to prevent settling or shifting of
thc tank.
17034 NORTH EAGLE RIVER LOOP ° SUITE 204 ° EAGLE RNER, ,N_A~KA 99577
Page 2
Lot 33, Block 2, Willlomson #2
February 13, 2001
All standpipes on the septic tank shall extend a minimum of 12 inches above final grade.
Septic tanks installed with less than 4 ft. of cover shall be insulated.
A foundation cleanout shall be installed one to four feet' from the building foundation. In
the line between the tank and the leachfield there shall be two adjacent cleanouts (unless
an effluent pumping system exists within the septic tank). These cleanouts shall be
located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line,
shall be to clean toward the leachfield. The second cleanout shall be to clean toward the
septic tank.
Final grading over the septic tank shall be such that a positive slope exists away from the
septic tank.
ABSORPTION TRENCII/DRAINFIELD INSTALLATION:
Excavate the proposed trench to the dimensions shown on the design. The bottom of thc
excavation shall be within 2 inches of level. If the sidewalls of the excavation become
smeared, they must be raked or scratched (ruffed-up) before gravel (sewer rock)
placement.
Once the gravel is installed, the distribution pipe is to be installed level with the
perforations faced downward. Gravel is then to be placed over the distribution pipe to
provide a minimum of 2 inches of cover over the pipe.
A silt barrier must be installed between the final gravel layer and the native soil backfill.
Ensure the silt ban'ier covers the entire gravel surface before placing backfill.
Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations
shown on the design, and extend a minimum of 12 inches above final grade. The portion
of the monitoring tube extending through the gravel shall be perforated from the bottom of
the trench to the invert of the distribution pipe. This is equivalent to the effective depth of
the gravel as noted on the design.
Backfill over the final gravel layer must not be less than twenty-four (24) inches.
Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The
finish grade over the trench must be mounded to prevent the formation of a depression
after settling.
Page 3
Lot 33, Block 2, Willlamson #2
February 13, 2001
MINIMUM MATERIAL SPECIFICATIONS:
Any septic tank proposed for installation must be constructed by a Municipal approved
septic tank manufacturer.
The following pipe materials are approved for use in septic system installations in the
Municipality of Anchorage:
Type of Pipe perforated Solid
Cast Iron Yes Yes
ASTM D3034 (PVC) Yes Yes
ASTM F810 (tlDPE) Yes No
ASTM D2662 (ABS) Yes Yes
Use of a type of pipe other than listed above must be approved by the inspecting engineer.
Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical
Company Styrofoam HI or equal).
Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or
equal).
A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed
between the final leachfield gravel layer and the native soil backfill.
All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3%
passing the #200 sieve.
When sand is being used as a filter material, its gradation specifications must conform to
current M.O.A. or D.E.C. requirements, which ever requirement applies.
INSPECTIONS:
Typically there will be a minimum of three (3) inspections required during the installation of the
wastewater disposal system. These inspections will occur as follows:
n,t° ·
I~oge 4
Lot 33, Block 2, Willlorn~on
Februar~ 13, 2001
The first inspection must be conducted after the excavation of ditches, pits,
trenches, or beds and before the installation of any gravel. A septic tank may be
set in place, but may not be backfilled before this inspection.
The second inspection must be conducted after the placement of the silt barrier,
gravel, distribution lines, standpipes, cleanouts, and insulation, but before the
placement of any other backfill.
3. The final inspection is to occur upon final grading ofthe property.
Often there will be more than these 3 inspections required. Especially with the installation of
multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer
is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-
construction meeting will take place on-site. The inspecting engineer will not coordinate, direct
or control in any way the contractors activities.
The owner shall contract with the contractor to perform the work outlined in these specifications
and plans and in accordance with the attached M.O.A. permit. There will be no contractual
arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be
the owner's representative and will inspect the work as stated above to document the contractors
activities. Final acceptance of the contractors work rests with the owner and the M.O.A.
S & S Engineering shall have no liability to the owner or to others for acts or omissions of the
contractor or any other persons performing work on this project or the failure of the contractor to
carry out the work in accordance with these construction documents. S & S Engineering's
inspecting engineer will not be responsible for the construction means, methods, techniques,
sequence, procedures or the safety precautions incident to this project.
CONTRACTOR / INSTALLER
rlODERT C. COWAJ'I, P.E.
ROBERT A. SI IAI'Ell, r~E.
CML ENGINEErIS
(907) 694-2979
FAX (907) 694-12
Municipality of Anchorage.
DEPD~RTMENT OF }IEALTII AND ItUHAN SERVICES
825 L Street
P.O. Box 196650
Anchorage, Alaska 99519-6650
4
Tile septic in~pe~tions for t~e .referenced property were
performed on~-/~/o( and ~/q/~( . Prior to submitting
tile On-site Wastewater Disposal System and/orWell Inspection
Report we are waiting for the ~ r/o ~ ~ to be
completed. ~$~v~ur SU~
If we may be of further service please contact us.
Sincerely,
Z P.E.
R~ Cowan,~%~
7034 NORTH IiAGLE EI~EI'I LOOP · SUITE 204 · EAGLE RIvEn, N,.k~ KA ~577