HomeMy WebLinkAboutKNIK HEIGHTS BLK H LT 14Knik H
ights
Block H
Lot 14
#017-372
-14
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
hftp://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP241355
Work Type: SepticTank Upgrade
Tax Code Number: 01737214000
Site Legal Address: KNIK HEIGHTS BLK H LT 14 G:2836
Site Mailing Address: 12941 RIDGEWOOD RD, Anchorage
Owner: ALBERT DENNIS
Design Engineer: FIRST WATER CONSULTING
This permit is for the construction of:
Effective Date
Expiration Date
Lot Size in Sq Ft:
Total Bedrooms:
10/21 /2024
10/21 /2025
43500
❑ Disposal Field 2 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions: Prior to any future COSA approval, Letters of Non Objection are to be secured from the
utility companies for the water well in the utility easement.
Received By: is 5 Date:
Issued B /
y� t t1 �� Date:
4
MUNICIPALITY OF
Development Services Department
On -Site Water & Wastewater Section
Parcel I.D. 017-372-14
ANCHORAGE
ON -SITE SEPTIC/WELL PERMIT APPLICATION
Property owner(s) ALBERT DENNIS Day phone _
Mailing address PO BOX 90602, ANCHORAGE, ALASKA 99509
Site address 12941 RIDGEWOOD ROAD, ANCHORAGE, ALASKA 99516
Legal description (Sub'd., Block & Lot) KNIK HEIGHTS BLOCK H LOT 14
Legal description (Township, Range & Section)
Lot Size 43,500 Sq. Ft. Number of Bedrooms
In
Phone: 907-343-7904
Fax: 907-343-7997
16'
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑
Initial ❑
Single Family (SF) 113
(w/wo ADU)
Septic Tank
®
Upgrade EA
Duplex ❑
(D)
Holding Tank
❑
Renewal ❑
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION
INCLUDES A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature-.Qf,property owner or authorized agent)
Permit/Rush Fees:1225 Waiver Fees:
Date of Payment: 0 Date of Payment:
Receipt Number:
Permit No.
r
Receipt Number:
Waiver No.
GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc
13030 Sues Way, Anchorage, AK 99516
907-350-9566 / FirstWaterAK@gmail.com
!
!!
October 14, 2024
Municipalities of Anchorage
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
RE: SEPTIC TANK UPGRADE PERMIT
LEGAL: KNIK HEIGHTS BLOCK H LOT 14
The owner has requested that we obtain a septic permit to upgrade the existing aged steel septic
tank on the above referenced lot. For current functionality and future consideration or flexibility,
we propose to install a 1500-gallon HDPE deep-burial septic tank per the attached design to
serve the existing 4-bedroom residence.
Groundwater was not noted in the MOA on-site file and is not anticipated to affect the septic
tank installation. If groundwater is encountered during installation that may affect this septic tank
upgrade, an epoxy coated steel septic tank or other action may be required.
The lot and area are served by private water and any encroaching wells, easements, … must be
staked prior to construction. The design will not impact any of the neighboring properties.
Please contact us if you have any questions.
Sincerely,
Curtis Huffman, P.E.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241355, Curtis Townsend, 10/21/24
FIRST WATER CONSULTING
KNIK HEIGHTS BLOCK H LOT 14
DESIGN DETAILS:
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241355, Curtis Townsend, 10/21/24
Municipality of Anchorage Page
DEPARTMENT OF HEALTH AND HUMAN SFRVICES
ENVIRONMENTAL SERVICES DIVISION
1~.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: -4c'J ¢l~'°c'l~f PID Number: o1'/ "3 '7~
N~": C~ ~r,¢~ C. ~u Ce ~¢~ Wastewater System: ~ New ~ Upgrade -
Address: ~l ~l ~J ~
~ ~,0~,,~ ~,,.' A~,o~,~ ABSORPTION FIELD
No. of Bedrooms:
Phone: .~' ~ ~ ~ ~ '~ ~ ~ Deep Trench ~ Shallow Trenc~ Q Bed ~ Mound B Other
Total Depth from original grade:
LEGAL DESCRIPTION SoilRating: /' Z GPD/Sq. Ft.
~ot; ~ Block: ~ Subdiv~[on:~]~ ~Et6~T~ Depth to pipe bottom from odginalj~grade: Ft, Gravel depth beneath pipe ~ Ft~
Township: Range: Section: Fill added above original grade: Gravel length:
Gravel width: Number of lines: Distance between lines:
WELL: ~s-~,a~ New ~ Upgrade / :~> Ft. J - -~ Ft,
~lassification (Priwte, A,B,C): Total Depth: ~To: Total absorption area: Pipe material:
~riller:// ~e Drilled: Static Water Level: Installer~ ~ ~6E ~y~-r~$ Date installed:~ -
Ft. -
~ield: ~Pump Set at: Casing..~¢ A~o,. ero,.,: TAN K
~./~ ~ j Ft. Ft.
SEPARATION DISTANCES ~ s~p~ic a Ho~di.g u S.T.E.~.
To Septic Absorption Lift Holding ~ublic/Private Manufacturer: Capacity in gallons:
From Tank Field Station Tank Sewer Lines ~ ~O~-~ ~ j '~ ~ O --
Number of Compartments:
Welk I cot + i°ot 'E ~ '~ ~ ~ ~ Material: ~¢~b
s.,.o~ ~ LIFT STATIC N
Water ~i~ i ~ol + .... ~ --
LineL°t '~ ~ ~ ~O i ~.~ .~ .~ Size in gallons: Manufacturer: ~~
"Pump on" level at: ~~' level at: High water alarm at:
Foundation
Curtain -- ¢c~E I~ 4E',¢ ~ ---~ P:~ Electrical Inspections performed by:
Drain ..
Remarks: BENCH MARK
Location and Description: ,~ tV~
Assumed Elevation:
Inspections perJorm~lCe~j:(=rk==p.qe~.=~ Dates: 1st E-~z-~lL
H~~fl :~'~ ~'' -z~--,',~ ~,, c~
Department
of
He~It~and
Services approval ~. .... . '. ,,.-' ¢..
Permi't No,
SW960074 2 2
Page of
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 e Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
LOT 14, BLOCK H, KNIK HEIGHTS S/D 017-572-141
Legal Description: PID No.:
SEPTIC T~NK~
NEW TREI4CH~ L 5 ~0' UTIL, ESMT.
MT2 ...... TH
LC'T;
~ INSU~'I'ION~ I liH
/
NO ~ROUND WATgR ..
72-013 A (Rev. 9/91) MOA 25 '~ ~. C,. ~,
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
PAGE 1 OF 1
ANCHORAGE, ALASKA 99519-6650
ON SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT ~'-~
PERMIT NUMBER:SW960074 DATE ISSUED: 5/14/96
DESIGN ENGINEER:S & S ENGINEERING EXPIRATION DATE: 5/14/97
OWNER NAME:SCHREIBER CRISTINA C
OWNER ADDRESS:12941 RIDGEWOOD RD
ANCHORAGE, AK. 99516
PARCEL ID:01737214
LEGAL DESCRIPTION:
KNIK HEIGHTS BLK
H LT 14
LOT SIZE: 43500 (SQ. FT.)
NUMBER OF BEDROOMS: 4 THIS PERMIT: 4
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN~
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAAC80) .
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
EXTEND MONITOR TUBE TO EXISTING SYSTEM IF IT IS
TO BE USED IN THE FUTURE, AND MAINTAIN AMINo HORIZ.
SEPARATION/DISTAN~f/fTT.~WEEN TRENCHES.
RECEIVED BY~
ISSUED BY:~.~l/~
DATE:
DATE:
ROBERT C. COWAN, RE.
ROBERT A. SHAFER, RE.
May 3, 1996
CIVIL ENGINEERS
(907) 694-2979
FAX (907) 694-1211
HEALTH AUTHORITY
APPROVALS
SEWER &WATER
MAIN D(TENSIONS
SEWER&WATER
INSPECTION
ENGINEERING STUDIES
AND REPORTS
WELL INSPECTION
& FLOWTEST
SITE PLANS
ROAD DESIGN
SOIL 'rEST
PERCOLATION
TEST
STRUCTURAL &
MECHANICAL
INSPECTIONS
ONSITE
WASTEWATER
DISPOSAL SYSTEM
DESIGN
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
P.O. Box 196650
Anchorage, AK. 99519
REFERENCE: Lot 14,Block H, Knik Heights S/D
Request you issue a permit to upgrade the septic system
serving the existing four bedroom house on the referenced
property.
A test hole was excavated and percolation test performed.
The approximate location of the test hole is located on the
attached site plan.
At the time of excavation water no was encountered. The
monitoring 'tube has been checked and found-to be dry.
Attached is the proposed upgrade design.
We do not anticipate any adverse effects on neighboring
wells, septic systems or drainage patterns by the
installation of the proposed septic system.
The proposed 1250 gallon septic tank is to be placed
outside the well protective radius. Attached is a site
plan which depicts the location of the proposed tank.
If you require additional information, please contact us.
Sincer, el_¥ ,__
Robert C. Cowan, P.E.
RCC/gk
Enclosure
17034 NORTH EAGLE RIVER LOOP o SUITE 204 · EAGLE RIVER, ALASKA 99577
/
/
RIDGEWOOD
SITE PLAN
/
~OAD
gf]l(IVH 'Iq~A ,OOI
F-
o
.--t
UTIL. ESMT.
DESIGN
F
ROBERTC. COWAN, RE.
ROBERT A. SHAFER, P.E.
CIVIL ENGINEERS
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MATERIAL SPECIFICATIONS
(907) 694-2979
FAX (907) 694-1211
HEALTH AUTHORITY
APPROVALS
SEWER&WATER
MAIN EXTENSIONS
SEWER&WATER
INSPECTION
ENGINEERING STUDIES
AND REPORTS
WELL iNSPECTION
& FLOW TEST
SiTE PLANS
ROAD DESIGN
SOIL TEST
PERCOLATION
TEST
STRUCTURAL &
MECHANICAL
INSPECTIONS
ONSITE
WASTEWATER
DISPOSAL SYSTEM
DESIGN
REFERENCE: Lot 14, Block H, Knik Height S/D
May 3, 1996
GENERAL:
1.
The scope of this project includes the installation of
a 1250 gallon septic tank and a leachfield trench to
serve the four bedroom residence located on the
referenced property. The existing trench is to be
abandonc~as such that it may used in the fur and
the existing 1250 gal septic tank is to be excavated,
pumped, crushed, and abandoned completely.
Construction shall be in accordance with the approved
site plan and design drawings, Municipal permit with
any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal
Regulations.
The contractor shall be responsible for obtaining any
necessary underground utility locates.
Unless specifically agreed otherwise, the property
owner shall be responsible for final grading areas
subsequently depressed from soil settling.
Contractors installing wastewater disposal systems
must be certified by the Municipal Health Department
for system installations. Owners installing their own
systems must also receive prior approval from the
Municipal Health Department.
SEPTIC TANK INSTALLATION:
A septic tank is to be constructed by a certified
septic tank manufacturer. Construction shall include
two 4" cleanouts for pumping access.
2. The septic tank shall be sufficiently bedded to
prevent settling or shifting of the tank.
Ail standpipes on the septic tank shall extend a
minimum of 12 inches above final grade.
17034 NORTH EAGLE RIVER LOOP ' SUITE 204 · EAGLE RIVER, ALASKA 99577
Page Two
Lot 14, Block H, Knik Heights S/D
May 3, 1996
Septic tanks installed with less than 4 ft. of cover shall
be insulated.
A foundation cleanout shall be installed one to four feet
from the building foundation. In the line between the tank
and the leachfield there shall be two adjacent cleanouts
(unless an effluent pumping system exists within the septic
tank). These cleanouts shall be located on undisturbed
soil not more than 10 ft. from the tank. The first
cleanout, in line, shall be to clean toward the leachfield.
The second cleanout shall be to clean toward the septic
tank.
Final grading over the septic tank shall be such that a
positive slope exists away from the septic tank.
ABSORPTION TRENCH/DRAINFIELD INSTALLATION:
Excavate the proposed trench to the dimensions shown on the
design. The bottom of the excavation shall be within 2
inches of level. If the sidewalls of the excavation become
smeared, they must be raked or scratched (ruffed-up) before
gravel (sewer rock) placement.
Once the gravel is installed, the distribution pipe is to
be installed level with the perforations faced downward.
Gravel is then to be placed over the distribution pipe 'to
provide a minimum of 2 inches of cover over the pipe·
A silt barrier must be installed between the final gravel
layer and the native soil backfill° Ensure the silt
barrier covers the entire gravel surface before placing
backfill.
Monitor tubes shall be of four (4) inch diameter,
installed approximately in the locations shown on the
design, and extend a minimum of 12 inches above final
grade. The portion of the monitoring tube extending
through the gravel shall be perforated from the bottom of
the trench to the invert of the distribution pipe. This is
equivalent to the effective depth of the gravel as noted on
the design.
Page Three
Lot 14, Block H, Knik Heights S/D
Mat 3, 1996
Backfill over the final gravel layer must not be less than
twenty-four (24) inches. Insulation must be installed when
the backfill depth is less than thirty-six (36) inches.
The finish grade over the trench must be mounded to prevent
the formation of a depression after settling.
MINIMUM MATERIAL SPECIFICATIONS:
Any septic tank proposed for installation must be
constructed by a Municipally approved septic tank
manufacturer.
The following pipe materials are approved for use in septic
system installations in the Municipality of Anchorage:
Type of Pipe
Perforated Solid
Cast Iron
ASTM D3034 (PVC)
ASTM F810 (HDPE)
ASTM D2662 (ABS)
Yes Yes
Yes Yes
Yes No
Yes Yes
Use of a type of pipe other than listed above must be
approved by the inspecting engineer.
Insulation shall be at least 2" thick extruded direct
burial polystyrene (Dow Chemical Company Styrofoam HI or
equal).
Septic tank inlets and outlets shall be fitted with
watertight couplings (Caulder, Fernco, or equal).
A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N,
or equal) must be installed between the final leachfield
grave], layer and the native soil backfill.
Ail leachfield gravel (sewer rock) shall be 0.5"-2.5"
screened gravel with less than 3% passing the #200 sieve.
When sand is being used as a filter material, its gradation
specifications must conform to current M.O.A. or D.E.C·
requirements.
Page Four
Lot 14. Block H, Knik Heights S/D
May 3, 1996
INSPECTIONS:
Typically 'there will be a minimum of three (3) inspections
required during the installation of the wastewater disposal
system. These inspections will occur as follows:
The first inspection must be conducted after the
excavation of ditches, pits, trenches, or beds and
before the installation of any gravel. A septic tank
may be set in place, but may not be backfilled before
this inspection.
The second inspection must be conducted after the
placement of the silt barrier, gravel, distribution
lines, standpipes, cleanouts, and insulation, but
before the placement of any other backfill.
The final inspection is to occur upon final grading of
the property.
Often there will be more than these 3 inspections required.
Especially with the installation of multiple trenches, sand
filters, pressurized distribution systems, etc. Thus, the
inspecting engineer is to be contacted at least 24 hours prior
to the start of construction. If necessary, a pre-construction
meeting will take place on-site. The inspecting engineer will
not coordinate, direct or control in any way the contractors
activities.
The owner shall contract with the contractor to perform the work
outlined in these specifications and plans and in accordance
with the attached M.O.A. permit. There will be no contractual
arrangement existing between the contractor and S & S
Engineering. S & S Engineering shall be the owner's
representative and will inspect the work as stated above 'to
document the contractors activities° Final acceptance of the
contractors work rests with the owner and the M.O.A.
Page Five
Lot 14, Block H, Knik Heights S/D
May 3, 1996
S & S Engineering shall have no liability to the owner or to
others for acts or omissions of the contractor or any other
persons performing work on this project or the failure of the
contractor to carry out the work in accordance with these
construction documents. S & S Engineering's inspecting engineer
will not be responsible for 'the construction means, methods,
techniques, sequence, procedures or the safety precautions
incident to this project.
CONTRACTOR/INSTALLER
Municipality o! Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR:
LEGAL DESCRIPTION:
V/,.¥' ,,., , ,.,,o ,g,/_
Township, Range, Section:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15--
16
17
18--
19
2O
COMMENTS
SLOPE SITE PLAN
WAS GROUND WATER
ENCOUNTERED?
S
IF YES, AT WHAT -~ ~
DEPTH? p
E
Depth to Water Alter
Moniloring? ,bAY Date: ''~
I
Gross Net Depth to Net
Reading Date Time Time Water Drop
,hol ' .-
z- ~,/ ( ,.,,~ (, ~/~"
3 '. ~ ~ '7 % ~ /
~ ' ~'~ ~"~
PERCOLATION RATE I _ (m~nutes/mch) PERC HOLE DIAMETER
TEST RUN BETWEEN ~ FT AND (:) _ FT
_
~ ~ - = --. ~ ~..~ ~ - - , CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE ~~;~I::~;IDELINES IN EFFECT ON THIS DATE. DATE: '--/ ~ /`,~
72-008 (Rev. 4/85)
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL. PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street - Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAl_ SYSTEM AND/OR WELL INSPECTION REPORT
NAME
MAI LING ADDRESS
LEGAL DESCRIPTIQN
kOCATION
}-2
~UL~.
DISTANCE TO: I
Manufacturer 4~'~¢¢~---~"~' '~ 'Inside length
I Liq* capacity in gallons I ,~,,~
DISTANCE TO' Iwell
Manufacturer
I Well
ST*NC. TO:I
No. of lines , [ Length of each line
Top of tile to finish grade
L 4
~ngth Width
I~ss Dept~
I ~TO% ~uild,n~ found,I,o~
NEW
UPGRADE
NO, OF BEDROOMS
PERMIT NO.
No. of compartments
Liquid depth
Dwelling PERMIT NO.
Liquid capacity in gallons
Material
Nearest lot line
Fo,nOation~) /=~, /T''ench width
Total length of lines
~ r~" '~ "~_O inches
Material beneath tile
~~D ~ ~ ~FLinche2
Depth
PERMIT NO.
Distance between lines /V//~:~
Total effective absorption area
~04- FT'. ,2
PERMIT NO.
Crib depth Total effective absorption area
Building foundation Nearest lot line
Driller Distance to lot line PERMIT NO.
Sewer line Septic tank Absorption area(s)
OTHER
PIPE MATERIALS ,~.li
SOIL TEST RATING
INSTALLER
REMARKS
/.Ct ~';v ,¥c~
LEGAL
PERMIT NO.
DEPARTMENT : . WEALTH AND ENVIRONMENTAL .ROTEC]'ZON
825 ~1~~ STREET, ANCHORAGE, AK. D950t
264-4720
( 788;82 )
APPL I CAN]'
LOCf~IT I ON
LEGAL
MOtJNTAI N ENTERPRISES
R IDGEWOOD DRIVE
Lt4 B H KWIK HEIGHTS
SAR BOX t582N
LOl' SIZE
R I DGEWOOC.
4~500 SQUARE F'EET
]'YPE: OF SOIL ABSORBTION SYSTEM IS'i: TRENCH
MA~IMLJM NUMBER OF BEDROOMS
SOIL RATING (S~ FT?BR)= 125
THE REQUIRED SIZE OF' THE SOIL ABSORPTION SYSTEM IS:
THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAINFIEL. I>.
THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THIS SURFACE OF' THE
GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET).
THERE IS NO SET WIDTH FOR TRENCt4ES.
THE GRAVEL DEPTH IS THE MINIMUH DEPTH OF GRAVEL BETWEEN THE OUTFRLL PIPE
AND THE BOTTOM OF THE EXCAV8TION (IN FEET).
F:'ERMII' APPI.~ICAN'r HAS THE RESPONSIBILITY TO INFORM 'THIS DEPARTMENT DURING ]'HIS
INSTALLATION II',tSPECT]ONS OF ANY WELLS ADJACENT "FO THIS PROPERTY AND THE
NUMBER OF RESIDENCES THFIT 'THE WELL WILL SERVE.
BFICKFILLINC~ OF' Fti'.,IV SYSTEM 14ITHOUT FINRL IN'.F,.PEC, TION AND F:IPPI~O',,,'f~I. BY THIS
[:,EPRRTMENT 14ILL BE] SUBJECT TO PROSECUTION.
MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS
iE'~O FEET FOR A PRIVATE WELL,~ OR
,'1.50 TO 200 FEET FROM A PI..IBLIC HELL DEPENI)ING UPON THE TYPE OF PUBLIC HEEL.I,,..
14EL. L LOGS ARE REQUIRED AND MUST BE RETURNED TO TI4E DEPARTMENT HITHIN 30
OF THE WEL. L COMPLETION
OTHER REQUIREMENTS MflY FIPPL't'. SPECIFICATIONS AND CONSTRUCTION C, IFIGRRMS ARIS
FIVfl[LRBLE TO ~NSURE PROPER [NSTRL.L..RT[ON.
I CERTIFY 'THAT
1: I FtM FAMILIAR WITH THE REQUIREMENTS FCIR ON-SITE SEWERS AN[.', WELLS AS SET
FORTH BY THE MUNICIPALITY OF ANCHORAGE.
2: I WILL INSTALL THE SMSTEM IN ACCORDANCE WITH THE CODES.
2~:: I UNDERSTAND ,~THRT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE
RESIDENCE I$ REMODELED l'O INCLUDE MORE Tt4RN 4 BEDROOMS.
/-,
APPLICRNT MOUN]'~IN EN'FERPRISES
' ""' ..... . .... BAT F V3 "'2:
I .z,z, UED DY_
[~] SOILS LOG
PERFORMED
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
Pouch 6-650, Anchorage, Alaska 99602 276-222~[
SOILS LOG - PERCOLATION TEST
~'-~/-r~42 l~.t .'S~ (*I~UO .~'z-'{~- ~;):.'~'~ DATE PERFORMED:
[] PERCOLATION
TEST
LEGAL DESCRIPTION:
SLOPE
SITE PLAN
10
11
'12
13
14
15
16
'17
18
19-
20-
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
Gross Net Depth to Net
Reading Date Time Time Water Drop
PERCOLATION RATE
(minutes/inch)
TEST RUN BETWEEN FT AND -- FT
/~'~ df, It--l/~,rofJt/J ~'*~.tnfJ /tll'~r,~,~f~ 0~: /~-~
CERTIFIED BY; (~U:q(~-~2~/ ~. DATE:
72-008 (7/76}
WELL OWNER
WATER WELL LOG
FOSS DRILLING
1336 Ingra Street
Anchorage, Alaska 99501
,J ~_~r) USE OF WELL~~
SIZE OF CA~ING.~ 'j DEPTH OF HOLE~T. CASED TO /_~/~
oF D AWOOW .
FT.
REMARKS
DATE COMPLETED_
~PUMP TO BE SET AT
~_t o~
~_t o
~.t O__
~_t O~
~to~
___to.
___t O__
~t O~
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 South Bragaw SL
P.O. Box 196650 Anchorage, AK 99519-665~~,~ ~
www.d.anchorage.ak, us
(9O7) 343-7904
CERTIFICATE OF HEALTH ,AUTHORITY ,APPROVAL
FOR ,A SINGLE FAHILY DWELLING
Parcel I.D. 017-,372-14
GENERAL INFORMATION
Expiration Date:
Complete legaldescription KNIK HEIGHTS Lo'r 14 BLOCK H
Location (site address or directions) 12941 RIDCEWO00
Current Property o,~ner(s)
Mailing address
Lending agency
'k~ailing address
Real E. state Agent
Mailing address
LARRY BIGALKE Day phone 250-7618
12941 RIOGEWOOD ROAD .ANCHORAGE AK. 99516
Day phone
BARBARA BLOCK W/PACIFIC RIM PROPERTIES Day phone. 762-5417
3000 'C" ST. ANCHORAGE AK. 99503
Unless otherwise requested, HAA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 4
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding tank
[] Community On-site
[] Public Sewer
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer
of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or
water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority
Approval are valid far 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of
up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B
wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
Note: Alaska Water and Wastewater Consultants, Inc. shall be paid $1000.00 at, or pdor
to closing for the engineering services provided.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto end as of the validation date shown below, I vedfy that my
investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate
for the number of bedrooms and b/pe of structure indicated herein. I further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm ALASKA WATER &: WASTEWATER CONSULTANTS, INC. Phone
Address 6901DEBARR ROAD, SUITE 2B ° ANCHORAGE, AK 99504
Engineer's Pdnted Name JEFFREY A. GARNESS, P.E.
Date
337-6179
o
Engineer's Comments:
In conducting this eva/ua§on, A WWC, Inc. attempted to provide a thorough, ·
conscientious enginee~fng analysis of the system in accordance with ADEC end MOA
DSD Guidelines & Regulations. The reported results descrfbed the performance of the
system under the conditions encountemd at the time of the test, and separation
distances measured to readily identifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
#uctuate dudng the year. and ~he water usage of the family being served by the system.
' These conditions are oufside the cent/el of the evaluator of the system. Safisfactory test
results do not guarantee future performance of the system, horde they guarantee that
there are no hidden defects or encroachments. AWWC, Inc. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report Is for
the sole benefit of the owner listed above. Any re/ianca upon or use of this report by any
other person or party is not authorized, nor will it confer any legal #ght whatsoever.
ess."
'~',~. ... ~, ..' ..~
DSD SIGNATURE
~ Approved for Lit' bedrooms.
Disapproved.
Conditional approval for
bedrooms, with the fllowing stipulations: .t({((.l~f/.~/-f,.
,.q,~,'.,,. · .....
.. ..
,~- :~,.. .. ,.~ c
~. W^TERAND ·
Attachments:
HAA Checklist
Septic System Advisory
Well Flow Advisory
~,.'. ...... .' ~_~
Manitenance Agreements
Supplemen~l Engineer's Reort
Other
Original Certificate Date:
Municipality of Anchorage
Development Services Department
On-Site Water & W.~tewa~er Program
,1700 ~outh Bragaw St,
P.O. Box 196650 Anchorage, AK 99519-6650
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description:
WELL DATA
Well type Pmv^~
Date completed 6/25/78
Total depth 286 ft.
Date of test
Static water level
Well production 2
WATER SAMPLE RESULTS:
Coliform. 0 colonies/100 mi.
Date of =ample: 10/15/2001
B. SEFTIC/HOLDING TANK DATA
KNIK HEIGHTS LOT 14 BLOCK H
Parcel ID:
017-572-14
If A, B, or C provide P1NSID~ N/A
Sanitary esal (Y/N) YES
Cased to 140 lt.
FROM WELL LOG
6/25/78
106 .ft.
g.p.m.
well Log (Y/N)
Wires properly protected (Y/N)
Cesing height (ebov~ ground)
AT INSPECTION
lO/4/Ol
107 lt.
g.p.m.
1
Y
YES
18,+ in.
Nib'ate 1.03 m0JL.
Collected by:
Other bacteria 0 colonies/100 mi.
AWWC, INC.
Tank Type/Material STEEL
Tank elze 1250 gal. Number of Compartments 2
Foundafioncleanout(Y/N) YES Depresslonovertank(Y/N) NO
Dateinstelled 5/22/96
Cleanoute(Y/N) YES
Hlghwateralarm(Y/N) N/A
Date of pumping 7/13/2001 Pumper
C. ABSORPTION fiELD DATA
Date installed 5/23/96 Soil rating (~or ~rodrm) 1.2
Length 42 lt. Width 5 lt.
ANCHORAGE CESSPOOL PUMPING
Total depth ~ ~' e UT ff. Eft. absorption ama 500 ftz Monitoring tuba YES
Date of adequacy test 10/4/01 Results (Pass/Fall) PASS
Fluid depth in absorption field baforo test 10 in. Water added 855, gal.
Elapsed TIme: 754 min. Final fluid depth 24 in.
Any rejuveuaUon treatment (past 12 mo.) (Y/N & bjpa)
System type 0EEP TRENCH
Gravel below pipe 6 It,
Depression over field NO
For 4 bedrooms
42.5 in.
g.p.d.
New depth
Absorption rate >= 600+
NONE KNOWN If yes, giv~ date
O. UFT STATION
Oata installed Size in gallons M~_~N~'--~ __
"Pump on' level at in. "Pump n. High water alarm level at in.
Datu..._.._m Cycles tasted. Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
Absorption field on lot
Public sewer main
Sewer/septic se~ce line
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot 100'+
100'+
N/^
25'+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5' +
Water main N/A Watar sewloe line. 1 O' +
Wells on adjacent lots 100'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation 10'+
Watarsewloellne ' 10'+ . Sur~acewatar 100'+
Curtalndraln NONE KNOWN Wells on adJacent lots 100'+
F. COMMENTS
On adjacent lots 100'+
On adjacent lots 100' +
Public sewer manhole/deanout
Holding tank N/A
N/A
Absorption field. 5'+
Surface watar. 100'+
Water main N/A
Driveway, parldngNehlcle storage lo'+
G. ENGINEER'S CERTIFICATION
I cerlify that I have determined through field inspections and
review of Municipal records that the ebove systems are in
conformance wfth MOA HAA guidelines in effect on this date.
Engineer's Prlntad. Nan~e
Data
JEFFREY A. GARNESS
HAA Fee $
Date of Payment Io/z-~,'/O /
Receipt Number. ! 1"7~')
(Rev.
Waiver Fee $
Data of Payment
Receipt Number
BY: PACIFIC RIU PROPERTIE~;
0CT-2-0t 1t:36;
PABE 212
C
aVO~-J aOOM39Ol~J
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage. Alaska 99519-.6650
343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
Parcel I.D.# ~ [ ? ' ~ ? :z - /~/
1. GENERAL INFORMATION
Complete legal description
Location (site address or directions)
Property owner C
Mailing address ,' ~'94 ~ Ridq~wood ,,,~,.d
Day phone 75-3~62
Lending agency
Mailing address
Agent
Address
Day phone
Day phone
Unless otherwise requested, HAA will be held for pickup.
NUMBER OF BEDROOMS: 4
TYPE OF WATER SUPPLY:
Individual well ,~,,,,:.
Community well
Public water
NOTE:
If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
TYPE OF WASTEWATER DISPOSAL:
Individual on-site
Holding tank
Community on-site
Public sewer
NOTE:
If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72 025 {Rev I 91) ¢'~t MOA #21
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
S & S ENGINEERING
Name of Firm 1703-!. E=gie River ~ ,'~_,"_ ~_o~ ~n ~n4
Eagle River, Alaska 99577
Address ~ .~ . -~ /'
Engineer's signature .
Phone
DHHS SIGNATURE
~' Approved for ~
Disapproved.
Conditional approval for
bedrooms.
bedrooms, with the following stipulations:
Additional Comments
Date C/z ?./¢/_'
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. ']-he DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
Environmental Services Division
825 L Street, Room 502 · Anchorage, Alaska 99501 · (907) 343-4744
Legal Description:
Health Authority Approval Checklist
Bz~c I¢ l<,.,~¢c #-¢.~¢,//fJ' ParcelI.D.:
A. WELL DATA
Welltype PR~v/C T' ¢_.
Log present (~¢/N) ",/8 .~
/
Total depth 7), ~' (;
Sanitary seal ((~N)
Date of test
Static water level
Well production
If A, B, or C, attach ADEC letter. ADEC water system number
Date completed
/
Cased to ) '--/O
Casing height (above ground)
Wires properly protected (~N)
FROM WELL LOG
AT INSPECTION
f
;-% g~p.m. ")' $- g.p.m.
WATER SAMPLE RESULTS:
Coliform
Nitrate
Date of sample: ¢,
B. TAN .ATA
Date installed ~f/;~/~¢6 Tanksize /¢-,,¢-0
Foundation cleanout C/N) ¥
C. ABSORPTION FIELD DATA'
Length`· ~ ,)- width
EffeCtive absorption area ' ~&~'o
Depression (Y/~)
Purnper
Collected by:
Other bacteria
$ & S ENGINEI-'RING
Eagle Ri~er~ Alaska 99577
Number of Corn ~artments.
/,-, o High water alarm (Y/~I
Soil rating fF/bdrm) /*
3 / Gravel thickness below pipe
Monitoring Tube present(~/N) yc.~r Depression over field (Y/~)~__
System type z-
Total depth
Date of adequacy test/v//~ - N ¢~ M Results (Pass/Fail) For .~-bedrooms
Fluid depth in absorption field before test (in.); ~ Immedia[Cy~fter-"~"gal. water added (in.): __
Fluid depth (ins) M.~~~ Absorption rate = g.p.d.
Per, ox~i~ast 12 months) (Y/N) If yes, give date
72-026 (Rev. 3/96)*
D. LIFT STATION
Date installed Size in gallons
Manhole/Access (Y/N) ~n_D~Jevet-&t*"'---* "Pump off" level at*
High water alarm level at* ~ *Datum
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
olding tank on lot
Absorption field on lot
Public sewer main
Sewer/septic service line
On adjacent lots
On adjacent lots / o o -/--
Public sewer manhole/eleanout
Lift station
SEPARATION DISTANCES FROM~.~HOLDING TANK ON LOT TO:
/
Foundation /v o Property line ~- ~ ¥ Absorption field
Water main/service line ~0 /v-
Surface water/drainage / co Wells on adjacent lots
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line '~- ¢ :' Building foundation lq ~- Water main/service line
Surface water 2 o o
Driveway, parking/vehicle storage area
Curtain drain /v ~ ,v ~ /~ .¥ o w ,¢ Wells on adjacent lots
F. ENGINEER'S CERTIFICATION
I certify that I have determined thru field inspections and review of Municipal records th~
in conformance with M.~O~ideline~p effect on this date.
Signature
Engineer's Name
Date
HAA Fee $ ,.~¢2~
Date of Payment
Receipt Number
72-026 (Rev, 3/96)*
Waiver Fee $
Date of Payment
Receipt Number
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEAl_TH & ENVIRONMENTAL PROTECTION
825 L Street - Anchorage, Alaska 99501
ENVIRONMENTAL ENGINEERING DIVISION
Telephone 264-4720
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SFWER FAC!LiTiES
DIRECTIONS: Complete all paris on page 1. Incomplete requests will not be.~procassed, Please allow ten (10) days for processing,
1. "RO"ERTVOWNE>' L / f i ,ONE
2, BUY~ ~ ~ , PHONE
3. LENDING INSTITUTION
MAILING ADDRESS
4. REALTOR/AGENT PHONE
MAILING ADDRESS
;TREET LOCATION
6, TYPE OF RES. J~NCE NUMBER OF BEDRO_0~OM..~..~--
[~SING LE [] One ~ Four [] Other
FAMILY
[] Two [] Five
[] MULTIPLE FAMILY [] Three [] Six
7. WATER SUP~.J~Y
~ INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled
[] COMMUNITY since June Ig75, For wells drilled prior to that date. give well
[] PUBLIC U-FI LITY depth (attach Icg if available,)
~' INDIVIDUAL/ON-SITI:** **If individual/on-site, give installation aate ~
If system ~s over two [2) years old an adequacy test is required
[] PUBLIC U'FI LtTY by this Department.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-010(3/78)
THIS SIDE FOR OFFICIAL USE ONLY
DATE RECEIVED
INSPECTION APPOINTMENTS
TIME TIME TIME
DATE DATE DATE
INSPECTOR INSPECTOR INSPECTOR
DIRECTIONS:
1. TYPE OF RESIDENCE NUMBER OF BEDROOMS
[~' SI NG LE FAMILY [] ONE [] THREE [] FIVE [] OTHER
[] MULTIPLE FAMILY [] TWO [] FOUR [] SIX
PERMIT NUMBER
2, WATER SUPPLY
L~"INDIVIDUAL DEPTH OF WELL
EZ] COMMUNITY
DATE DRILLED
[] PUBLIC UTILITY
Connection Verified LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM ~ERMIT NUMBER*
E~-I~DIVI DUAL/ON -SITE DATE INSTALLED
[]PUBLIC UTILITY
Connection Verified INSTALLER
[]Septic Tank or E~Holding Tank
Size: /~),%' E-) If Tank is homemade SOILS RATING
give dimensions:
TYPE OF TANK MANUFACTURER
TOTAL ABSORPTION AREA MATERIAL
4~. DISTANCES Septic/Holding Tank Absorption Area Sewer Line I Nearest Lot Line
I
WELL TO:
Absorption Area to nearest Lot Line
5, COMMENTS
~'/'APPROV ED FOR ~ BEDROOMS
[] CONDITIONAL APPROVAL (letter must accompany certificate)
[] DISAPPROVED
DATE BY~ _~~
LEGAL DESCRIPTION
72-010 (Rev. 3/78)