HomeMy WebLinkAboutDEARMOUN LT 2I)eArmoun
Lot 2
#018-401-15
DTATEUKHT
A
D
2
N
r
2
W �W
�r � ��� r
r
�•dig
,• \ C
_
Z
z
E\�
Iv�0
9
r
m
<
Y
j -IN
1
C
—•Y
w
r0
.�
t
�3
r
O
t1
DTATEUKHT
ALL DRILLING
P. O. Box 9119
Anchoragc Alaska 99502
Phone 399-5567
Eq
A
D
2
N
r
2
W �W
ALL DRILLING
P. O. Box 9119
Anchoragc Alaska 99502
Phone 399-5567
Eq
DA 1C2a
o� 3DlOGb
A,: V/V. A c:
n
p r
r
W �W
�r � ��� r
r
�•dig
,• \ C
_
Z
z
E\�
Iv�0
9
DA 1C2a
o� 3DlOGb
A,: V/V. A c:
r'1 N
/65.00
SEEYfKIC SEo/t6AcN FE(D •.��
5�INOPIVf
SEPr�c — z—,
STfINO PIP 20
Ao /201 /
I rZI OG
4 LOT 1 / caOIN/
•J 1 ^
z'13
L(;Ajll
If o
/ LOT
coo
� I I
I Q
I
FovNO /
1" I ROW
of rl ✓F
WELL
FOUND
I")RO4
rrg� PIPE
30
+ _ N
00'07'30
W
_
30
ERON
GOAD
LOT
I6
Fovw)
1 � " !Roa PIPE
LOT
1, EGElJD
/ter
WELL
J E.OF At. IN
AS QUILT
LOT 2 DE ARMOUN
SURVE
SUBDIVISION
, �*!agm
ANCHORAGE
RECORDmr,
PRECINCT ALASKA
✓AMES B. RODGERS
I. f �............
`I �o+..e.p�•�y.:�L;;S� Registered Land Surveyor
♦� r,,ti. 140.4367S SRA Box 16/6 C
✓j) .,, �.•,,.�. ".; Anchoroge,Alosko 99507 (907/345.0927
Oaf• Sccl•I Orwn.by I F.9. 1 Gr/O J S&Int
Aua. 63 1 "=50'1 Z/T 2935 /of /
' APPLIC" NT FILLS OUT UPPER HAIL ONLY
Time
Property Owner ��
Phone
gating Address - ZIP Code
Date
Buyer
Date
Date
Address Zip Code
Lending Institution i G%� ' LZ:�/) l/���C�'�
Phone
pcx
�� �'�-i/(�/P�`
Inspector
Address p�-O ,J /) �. Zip Code
Inspector
Realty Co. & Agent 'n
Phone
Address Zip Code
!+
Legal De.scrlption . LO 7' :J/
o �GC �j/✓�O(///� j l//S.
Street Location -� Cof'v/�/ I OHO
Field Notes:
Type of Residence
&'f Single Family
�� _
0Multiple Famlly-la No. of Bedroom
6'E4 LL, :
❑ Other
Water Supply
'
RECEIVED
Individual
ATTACH WELL LOG. A well log Is required for all wells drilled since June 1975.
O Community
For wells drilled prior to that date, give well depth (attach log
If available).
O Public Utility
DATE �a
Sewer Disposal
`
CTr Individual Year Individual Installed:
B �
❑ Public Utility When Connected to Public Utility:
❑ Holding Tank
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
Soils Rating
M
Time
Time
Time
Time
Date
Date
Date
Date
Inspector
Inspector
Inspector
Inspector
Field Notes:
MUNICIPALITY OF ANCHOP.A
DEPT. OF HSPLTH P.
PROTECTION
�� _
ENVIRO�'AcNTAI
6'E4 LL, :
AUG I
'
RECEIVED
( ;C) APPROVED BEDROOMS -.. 'CONDITIONS OF APPROVAL
( ) DISAPPROVED
( ) CONDITIONAL APPROVAL*
DATE �a
`
B �
r -
Soils Rating
Date Sewer Installed
Well To Absorption Area
Well Log Received
Septic Tank Slze
Well to Tank
tzazz IM
1) FA ---------------------
p `
i
August 23, 19113
Slob and Laverne bodge
Printmore Corp.
920 E. Whitney Road
Anchorage, AK 995
Subject: Lot 2, DeArmoun Subdivision
Approval for the individual sewer and water facilities cannot
be granted until the following items have been completed:
A well log submitted to this office for our files and
review.
° The top of the well casing should be sealed so that it is
water tight.
° The septic tank pumped with a receipt submitted to this
department. The total number of gallons pumped needs to be
on the receipt and verified by a registered engineer as to
the actual number of gallons pumped. This is to verify the
size of the septic tank.
° Expose the septic tank manhole to verify its existence.
° Locate and expose the cleanout to the seepage pit and/or
leaching area for our inspection. This is to insure the
minimum distance requirements are met between the well and
sewer system.
° An adequacy test needs to be performed on the existing
leaching area. This test will determine if the system is
adequate according to tlational Standards. A listing of \
private firms performing the test is enclosed. This report.
needs to be submitted to this office for our review.
r i.
Bob and Laverne Hodge
August 23, 1983
Page 2
° Doth Systems will need to be tested.
° Your well serves more than one dwelling and you need to
contact State of Alaska, Department of Environmental
Conservation, 274-2533, to register your well.
Please notify this Department for a reinspection when the
noted discrepancies have been corrected. If there are any
further questions, please call this office at 264-4720.
Sincerely,
J. S. Roberts
Assistant Environmental Specialist
JRG/ej/E2
Enclosure
(1 �
ENGINEERING INNOVATION IN 1HE FAR NORTH
ARCTIC ENGINEERS, INC.
ENGINEERING STUDIES• DESIGN. CONSTRUCTION MANAGEMENT. SURVEYING
September 14, 1983 AEI# 83-013-26
J.S. Roberts
Assistant Environmental Specialist
Department of Health and Environmental Protection
825 'L' Street
Anchorage, Alaska 99501
Re: Approval of individual water and sewer facilities for Lot 2, DeArmoun Subdivision.
Dear Mr. Roberts:
This report is in reference to a letter from your office dated August 23, 1983
to Bob and Laverne Hodge. Eight items were necessary to receive approval
for the water and sewer facilities. Arctic Engineers inspected the facilities and
procured necessary information to yield the following results:
1) The well log is included with this report.
2) The top of the well casing has been properly sealed so it is water tight.
3) The septic tank was pumped after the adequacy test was conducted. Approx-
imately 800 gallons of sewage was extracted. It is the opinion of the
pump operator and the on-site inspector that the tank volume is approximately
1000 gallons.
4) The septic tank existence was verified in the field by the inspector and
pump truck operator.
5) The seepage pit and/or leaching area cleanout was exposed for the adequacy
test. The distance requirement for the well is addressed in item 7.
6) An adequacy test was performed and is included with this report. The
system is adequate to meet Municipal Standards.
7) The well was inspected and the following items were found to be in compliance
with Municipal Standards:
a) Casing extends 12" above ground.
b) Ground surface around the well is sloped away from the well.
c) Well cap is properly sealed.
d) All wiring is in electrical conduit.
e) Water analysis for total coliform is satisfactory. Test results
are included.
f) Distances from the septic system are marginal. The well was found
to be 109' from the septic tank. The leach field is 98' from the
well. This is 2' short of the requirement and a waiver is requested
for this item.
8) The well presently serves more than one dwelling. A waiver from the ADEC
is uhobtainable:due to'-the:.distance-tn-:the=seepage area.:: An'.alternative
to system improvements or the ADEC waiver is to evict the person in the
one-bedrrom studio apartment. A copy of the eviction notice is enclosed,
eliminating state requirements for a "Class C" system.
ARCTIC ENGINEERS, INC. 1500 W. 36TH AVENUE• ANCHORAGE. ALASKA 99503.9071277-8593
3901 PATRICIA LANE • ANCHORAGE. ALASKA 99504 • 9071333.9428 (ACCOUNTING)
n
n
I hope this answers all questions and aids in facilitating system approval.
If you have any questions or problems, please call.
Sincerely,
ARM ENGINEERS, I
o sRgan
Environmental Engine
September 2, 1983
Robert C. Hodge
13900 Ervin Road
Anchorage, Alaska
LEGAL:
OWNER:
HOUSE TYPE:
WATER:
SEPTIC
SYSTEM:
TEST DATE:
E :::NEERIMG INNOVATION IN THE FAN NORTH
ARCTIC ENGINEERS, INC.
F'• ' • -. ] : "' D!: 6.ON • COW70ZJGTIOM MANACPAENT . SURVEYING
AEI# 83-013-26
SEPTIC SYSTEM ADEQUACY TEST
Lot 2, DeArmoun Subdivision
Robert C. Hodge
2 -bedroom house, 1 -bedroom studio, total 3 -bedrooms
On -Site Well
Tank:
Unknown
Absorption
System:
Unknown
Absorption
Area:
Unknown
Approval
Date:
Unknown
September 1, 1983
PROCEDURE: The adequacy test was started at 11:00 a.m.. No record of the
existing system was available. We were unable to contact the
original owner and system installer in Washington State.
Two standpipes were located near the studio apartment. The
toilet was flushed while observing the septic tank to
verify tank location. Water from a tank truck was dumped
into the leach field or crib in 100 gallon increments with
liquid rise in the standpipe measured after each increment.
ARCTIC ENGINEERS, INC. Al A,I<A 90503.907'277.8593
t . !.•.I•+ArE A :. ;r.n 99504 . 90713213 9,128. (AccouNnr.c)
n
Robert C. Hodge
Adequacy Test
83-013-26
-2-
W
PROCEDURE:
%lien 700 gallons had been added, a minimal rise was noted
(cont'd)
with no backwash into the septic tank. At that time, addition
of water was halted and the septic tank was pumped.
The calculated rate of rise in the pipe was 350 gallons per inch.
Absorption monitoring was not carried out due to the small rise.
The liquid level decreased to its original level within five
minutes after filling with water. No ground seepage or other
outlets were located.
RESULTS:
The daily absorption capacity of 450 gallons per day required by
the Municipality was exceeded by a factor of 1.55 without any
appreciable rise in the liquid level. The soil absorption system
meets Municipality of Anchorage requirements.
COMMENTS:
Excessive solids were noted in the seepage pit. A number of
possible reasons exist for this but not knowing the type of
system, limits them to speculation. The pit should be pumped
periodically along with the tank.
-- zS -
Timis' ,�
0
S/
Top
1"7:o4%Vif7
1177
��iO�OGOr�'�OS % �