Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DEARMOUN LT 4
I)earmoun Lot 4 #018-401-13 (Nev ub/uz/l C) Municipality of Anchorage , On-Site Water and Wastewater Section • (907) 343-7904 Page 2 of 2 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP211154 PID Number: 018-401-13 Dwelling: ❑® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New [M Upgrade Name Higgins Family Living Trust ABSORPTION FIELD ❑ Deep Trench E:1 Wide Trench REM Bed [:1 Mound Site Address 13800 Ervin Road ❑ Other Phone Number of Bedrooms Soil Rating depth from original grade 4 0.5 GPD/SF JTotal 5.4 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4,9 Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot Dearmoun 4 Fill added above original grade 0 Ft. Gravel length 60.0 Ft. Township Range Section Gravel width 25.0 Ft. Beds: Number of Lines 5 Distance between lines 5.0 Ft. SEPARATION DISTANCES To Septic Absorption Holding I Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station Tank I Line 1500 Ftz 1 N/A Ft. Well NA 100'+ NA NA 125'+ TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Capacity Surface WaterNA 100'+ ' NA NA I Gal. Material Number of compartments Lot Line NA I 10'+ NA i NA NA Foundation NA 10'+ I NA I NA LIFT STATION Manufacturer Capacity Remarks Gal. Alarm location Electrical installed by PIPE MATERIAL House to tank Tank to 3034 Installer drainfield A+ Excavation Drainfield 3034 Co/MT3034 Inspector Pannone Engineering BENCH MARK (Assumed elevation) 348 It Inspdeact sn est 05/27/21 05/29/21 Location and description 3rd 2„d aih Nail on Tree Closest to Field ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional Approval: Date 9 W a,lever! P Panr o.) "fit Septic System Approved 1�-- Date 1�-S7' Z� c- _ Note: this approval does not include well permit requirements. (Nev ub/uz/l C) -q -nnm .: —'D `-c� +v)o--a:cO n n W n N n -. ,I K is CD, KK:o W N-< Dx z�GAC)y�(nmD�- D O D 3�mc7m10— X T) M DCNn �Oo-r n < Cn N c�z�zz`— °—'D D d O= O N rn N O N z r �'nyOG� m 66 rn Lj -P O �I O 00 .� M _+COC- o m co z z 6) Cp z MAc�O U] -' -P z m O D m gr- -D-i z O r- m m M M - D r 2z W -P O Nm NOTES: RECORD DRAWING n n n W n N n -. K O K is K -P KK:o W N-< Dx z�GAC)y�(nmD�- D O D n N DCNn n f Cn N Cn N O N rn N rn W rn Lj -P O �I O 00 .� M J V v N 6) Cp O -! O) O -' -P D o - N -P O W -P O O J 'P N •P N N O) P W P W :A •P :P U) :P M •P -P :P 0 00 00 lb W N v p) O W 07 N O O Ln N - O0 O O O O W -. N 0 0 0 �1 -1 0) O o C K (n D D U) -0 7 z � ;J D 0 A 5 p- 2 -o a l -1 Drib lc/1 r�1 � cn m 0 � z • r Dr r C)7\CO 17 - > F' (/ Dx z�GAC)y�(nmD�- D O D DCNn = ��� zm ipm(AM f EFVIN ROAD 71L �p 1D O Cn� M z D OO 0 rp0--1 CnNCD (>0nZ r1 1n •T ,o rn O (A cn TI m U) K:- T1 W U z c D o O m o v 0 O (A --1 M (T x cn D N \ d :pl coM p cj� D mc ' a w v n I a l ox (Jim / V m � I DO Z oX f EFVIN ROAD m- z z —� — — \ f 0 0 0 m r r U) � -+n oz z ;u m p / z O i NZ 2 m I� Ny I C m o < m ;0 D mc ' a w v ox (Jim / V -• , N i U1 / DO Z oX f EFVIN ROAD m- z z —� — — \ f 0 0 0 � PANNONE ENG SVC LLC C.1. '1088) d����0\\ REVISIONS DATE P.O. BOX 1807 PALMER, AK 99645 � �� �F AC gS�I 06/09/2021 PHONE 907) 745-8200 FAX 907 745-8201 DEARMOUN L4 " DRAWN LJC HIGGINS FAMILY LIVING TRUST Steven•R. ROnnone CE 8149 N RD SITE PLAN ANCHORAGE, AK 99516 ALE 1 11 = 50' J.D. NO 018-401-13 ERMIT NO. OSP21154 HEET 1 OF 2 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http:/Iwww.muni.org/onsite Can -Site Wastewater Disposal System Permit Permit Number: OSP211154 Work Type: Septic Upgrade Tax Code Number: 01840113000 Site Legal Address: N L.T `-i Site Mailing Address: 13 Svc) C.t2V i Nj Owner: HIGGINS FAMILY LIVING TRUST Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Effective Date Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 5/21/2021 5/21/2022 Q Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: � Date: Issued By: Date: 5( 0 M MUNICIPALITY OF ANCHORAGE Community Development Department' Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 018-401-13 Property owner(s) Higgins Family Living Trust Mailing address Site address 13800 Ervin Road Day phone Legal description (Sub'd., Block & Lot) Dearmoun L4 Legal description (Township, Range & Section) Lot Size 49,500 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field X❑ Initial ❑ Single Family (SF)X❑ Septic Tank ❑ Upgrade (w/wo ADU) (D) ❑ Holding Tank ❑ RenewalDuplex ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE 1 WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 159.5 Waiver Fees: Date of Payment: �Il�/21 Date of Payment: Receipt Number: L'2L4 V--;7 Cr Receipt Number: Permit No. O S,"Q 11 15 q Waiver No. Permit App_:- :- :L. c- Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211154, Rebecca Carroll, 05/21/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211154, Rebecca Carroll, 05/21/21 b Ln L% GVO& & I V I i &3 —oO , 0 00"996 Ma0£,LO.00N C c N Q C C O CL_ a _ O 0 + b LU o6E._ U Ln C N ILL cc E U co _ LL m 0 O 0 Z a O V N N .+ N W 2� N C N O O Lt, V' N z n C Z W U n $ E o o C we .FL- w Q Q c, O a) J O v CL a) a) Q) m C m w U w o o U� 0-0 0 N C Q 41 O LO m ,u .0 L c m ° m N -0 0 @ 0 Q C �- 2 Na O O v w m-0 2 v, O m N C V C 0) uj 3 "O ° O .•.. ° C ° - J V% C d U d c y > m Z U 'oo ° S= $N _,cE�� O E QCD 12" m VOl COj C C ° CO �O U Ly a) t4 L- 0. O w 2 ` FL6 .N., y ti o o a ° aL LA °n > o to N ¢ 7 C U N U -6 aJ O w N O" C 7 O CO ° a) 30�aEis vp E 6 'OZ Lu E m m ac) La ]. Q t X —C 0VeWok v c C G "L9 y r) _ N a Lu o oN 5 8Yl 0 N u a a� m }J o za co m ° y O �Naci Q _J 0) N fa n Z ZL m O N O ' Z"6Z 4 � 'O N � N 00'996 3.,0£,LO o00S / Z 6107 £Z`107 t�Z 107 :103,903 !gZ 107 O v � O m c -- m a a) 0 O N Q. U L v c > Li) O L cu L y � ) � t a) Q) c� L G ai + U a1) m a) W Ln v E a a) E a) O_ 0 LD > a O N C O N D. C 00 1-1 Ln LT O1 LO Y E @ O Q U tLtLo N O � u i U C u Q=E J W 0 0 J a) ,!= U :t - Ln = 0> N Ln _ a) c > Q ` C/1 aC LD — L 00 -i C Ln O OL } LO w O oo U_ w rn 3 C c N Q C C O CL_ a _ > U LU o6E._ U Ln C N ° ° o _ LL m 0 O 0 Z a O V N N .+ N W 2� N C N O z n C n $ E o o C we .FL- w Q Q CL a) a) Q) m C m w U w o o U� 0-0 0 N C LO m ,u .0 L c m ° m -0 0 @ 0 C �- 2 Na O O v w m-0 2 v, O m N C V C 0) uj 3 "O ° O .•.. ° C ° - J V% C d U d c y > m Z U 'oo ° S= $N _,cE�� O E aI E m N N lT m VOl \ C C ° CO �O U a) t4 L- 0. O w 2 ` FL6 .N., y ti o a J F C a ° aL LA °n > o to N ¢ 7 C U N U -6 aJ O w N O" C 7 O .=0.. caami ° a) 30�aEis vp E 8 c Lu E m m ac) La ]. Q t X —C Q= a) E E v c C E s m o o m y r) _ N a Lu o oN 5 CL >` "� 0 N u a a� m }J o za co m ° y O �Naci Q _J 0) N fa _C C 0-O n CL N m O N O v E a a) E a) O_ 0 LD > a O N C O N D. C 00 1-1 Ln LT O1 LO Y E @ O Q U tLtLo N O � u i U C u Q=E J W 0 0 J a) ,!= U :t - Ln = 0> N Ln _ a) c > Q ` C/1 aC LD — L 00 -i C Ln O OL } LO w O oo U_ w rn 3 O CL_ a _ LU Ln C i Z/ Z _ NC W O` ° 0 N 0. L6( O V N N .+ N W 2� N �j a Or O moE� z n a) E n $ E o we .FL- w Q Q C7c NM 4 Municipality of Anchorage a` © Development Services Department Building Safety Division On -Site Water and Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page 1 of 2 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW070247 PID Number: 018.401-13 NameWilliam C, Higgins : Wastewater System: ❑ New ® Upgrade Atltlress: Box 111463 ANCH AK. 99511 ABSORPTION FIELD Phone: Number of Bedrooms: ❑ Deep Trench 0 Shallow Trench 0 Bed 0 Mound 0 ether: LEGAL DESCRIPTION Soil Rating: Total Depth from original grade: GPDyFt� Ft. Block: Lot: Sclor ision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: y DeArmoun Ft. Ft. Township: Range: Section: Fill added above original grade: Gravel Length: Ft. Ft. Well: [-I New El Upgrade Gravel Moth: Number of lines: Distance between lines: Ft. Ft. Classification (Private, A, B, C): Total Depth:eased to: Total absorption area: Pipe Material: Exist' Private Ft. Ft. Ft' PVC 3034 Driller: Date Drilled: Static Water Level: Installer. Daze Installed: Ft. Owner 1 9123/2007 Yield: Pump Set at: Casing Height Above Ground: TANK GPM P. F[. SEPARATION DISTANCES ® Septic ❑ Holding ❑ S.T.E.P. ❑ Other: To Septic Absorption Lift Holding ubtic/Private Manufacturer: Capacity: From Tank Field Station Tank Sewer Line Anchorage Tank 1250 Gal. Wall 107.9 126.3 Material: STEEL Number of compartments: 2 Surface Water 100+ 100+ LIFT STATION Lot Line 49.3 30.0 Size: Manufacturer: Gal. 5+ "Pump on" level at: "Pump "Pump otr level at: High water alarm at: Foundation in . in. Curtain 50+ Pump Make & Model Electrical Inspections performed by: Drain Remarks: TANK REPLACEMENT ONLY. Existing house was razed. A new 4 BENCH MARK BR house is planned for the near future. New service line will be Location and Description: TOP OF WELL installed with new house. Assumed elevation: 100.0 Ft. Engineer's Stamp Inspections performed by: PANNONE ENG. SVC, LLC Dates: 1' 9/23/2007 q��S444 2"' 9/2312007.�X,P��,OF `;�i� Development Services Department Approval �•.' TH Conditional Approval Date: �,,,•n .,•/ ....... Ir0 ................. . y Steven R. Pannone.- w `�1�%°•., r/\ Reviewed and approved by: !d Date: i q 0 No. CE 8149 �1 �2 (Rev. oarod) ... ��+�eI ESS; �•� EXIST'G SEPT\C \ EXIST'G 882 BED E 157'G SEPTIC TANK TO BE, U ED \ ABANDONED IN PLACE BED INSPXCTED A - PER CODE IS OPERA TINGIN6RMALLY- -\ �.�" /FOR 4 BR.'S \ ._.... __...___125 YEN 4 � S TA ` . 3 . D.. EXIS '3I 79... SERVICE LINE ` '• [ �2. _ `. TH BY ' --LEE RElD `'� � ] 10' ti1IN \ ..' SHED Q 0 a 2 _ EXIST'G E1 E2T1 �',\, 0 EXIST'G WELL 3BR ("t USE �� LOT J--':-57.8 DEMO I HED EXIST'G SEPTI _ SHED 26. BR RESERVE'„PED y A S STEM - 25'Wx60LFx0.5'ED;, 2.D TO GARAG_ SEE NOTES W '�...__,.......j PROPOSED 1 BRADDITIO �\ a 1) P,STG HOUSE DEMOLISHED. CO56.0 ''---DWNE PLANS TO BUILD NEW EXIST'G SEPTIC 7 1� �� 4`B OUSE IN SPRING. 2) NEWa,ERVOE, LINE WILL BE E1 100.7 1 3.8 INSTGALL� `•,WITH'NEW HOUSE E2 112.6 j24.5 T1 120.0 32.4 EXIST'G'WELL T2 126.6 X139.2 EXIST' s I CA �- C1 130.0 1143.0 o- 'C2 132.3 '145.4 DESIGN PARAMETERS ao 0 0 00 0 (UPGRADE FIELD ONLY) ow NO. BEDROOM: 4 TANK SIZE: 1,250 gallon PERC. RATE: 15.2 MPI SOIL RATING: 0.5 gpd/SF 92.9 0.1 APPLICATION RATE: 300 SF/BR AREA ROD: 1200 SF p T 485.2 SYS. TYPE: BED 0.5' ED, 25'W NEW 12 86.4 MIN LENGTH: 48 LF N USE: SEPTIC MiN.s�oce TANK s-o.o,w 6OLFx25'WIDE,0.5'ED,2.0' TD TOTAL AREA: 1500 SF l OFA�gsi`) 7]A7�i7�TON 1�1�T/"! C+C C, TTI+ rP.O.VBlO,IX REVISED Date 110,2199541 ANCHORAGE, AK 9J9.51100 RECORD DWG 12-10-07 Gj�P' Co..- PHONE (907) 272-8218 FAX (907) 272-8211 Scale P.I.D. NO ...... .. :.. "SfeJeri 'non DeArfnoun S/D, Lot 4 018-401-1 .' P / CE 8149 WlUiarl Higgins PERMIT NO. �/ 07.--_ PO Box 111463 SWO70247 DESIGN ��F��OFESSl Anchorage, AK 99511 sneer + PLAN 2 of 2 MUNICIPALITY OFANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 1 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Permit Number: SW070247 Legal Description: DEARMOUN LOT 4 Design Engineer: 0062 PANNONE ENGINEERING SERVI( Owner Name: WILLIAM C. HIGGINS Owner Address: PO BOX 111463 ANCHORAGE, AK 99511 - Date Issued: Sep 12, 2007 Expiration Date: Sep 11, 2008 Parcel I D: 018-401-13 Site Address: 13800 ERVIN ROAD Lot Size: 49500 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: ❑ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy All construction must be in accordance with: 1. The attached approved design. ❑ Private Well ❑ Water Storage 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Date: xl Issued By: /(v \ Date: Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.org/onsite (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. M- qLl- l-_�) Property owner(s) William C Hiuiains Day phone 242.8220 Mailing addressP.O. Box 111463, ANchoraae. AK Zip Code 99511 Site address 13800 Ervin Road Zip Code 99516 Legal description (Sub'd., Block & Lot) deArmoun SID. Lot 4 Legal description (Township, Range & Section) Lot Size 49,500 Sq. Ft. THIS APPLICATION IS FOR (® all that apply): Absorption Field ❑ Septic Tank Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Number of Bedrooms THIS APPLICATION IS AN: V!v Initial ❑ Upgrade Renewal ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. Pannone LLC (Signature of property owner or authorized`agent) Permit/Rush Fees: _ `t&() ` Waiver Fees: Date of Payment://J�� Receipt Number: 9 "! � 7.4 (Rev. 11105) Date of Payment: Receipt Number: Pannone Engineering Services, LLC Consulting Engineers (9071272-8218 September 2, 2007 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 S. Bragaw Street P. O. Box 196650 Anchorage, Alaska 99519 Subject: DeArmoun S/D, Lot 4 Septic Tank Replacement Permit Request Ladies and Gentlemen: P.O. Box 102954 Anchorage, Alaska, 99510 (907)272-8218 Fax I am writing to request that a permit to install a new septic tank be issued for this property. The system currently serves an existing three,bedroom house. The Owner wishes to construct a new bedroom and garage on the house. The lot is currently developed and is served by a private water system. 1. Tank Replacement. The original 1000 -gallon septic tank was installedprior to the 1984 upgrade to this septic system It is assumed the tank was installed when the house was constructed in 1963. From field observations, the tank is extremely corroded. The replacement tank is to be installed north of the existing tankand outside the 100 -foot well radius. A new 1250 -gallon septic tank will be installed. See the attached site plan. The existing drain field was inspected and found to be dry even though it was in use. It wastested and found to be able to accept the required 600 gallons required for a four-bedroom house. 2. Surface Water: There is no surface water within 100 feet of flee proposed system. 3. Topography: The septic drain field is located at the bottom of a small hill. The proposed septic tank will be installed uphill of the drain field and will have at least four feet of cover over the tank. 4. Upgrade to 4 bedrooms: The existing field was constructed to have 882 square feet of surface area. The soil was rated at 190 sf per bedrooms. The minimum area for afour-bedroom system at this soil rating is 760 sf. A reserve are is shown on the site plan and is sized based on the existing codes and apercolation rate of 16-30 minutes per inch. Lee Reid obtained a percolation rate of 15.2 mpi in 1984. The proposed installation will not affect the future development of tle surrounding or existing lots. There are no wells or septic systems within 100 feet of the proposed septic tank location. If you have any questions or concerns, please contact me at 227-3522 or 272-8218. Sincerely, .4* - _ . �F q� Q� ,1♦♦ TH �,,.� ................ Steven R. P none, P.E. ..... . .............. . Civil Engineer j_A?•Steven • Po none. o No. CE 8149 Attachments: �j�♦ . EV Work\Letters\4 DeArmoun.001.doc iE 5 0 3 ti I I � I \ I 1 III EXIST'G WELL tXISr'G SEPTIC—\ `\ EXIST'G 882�`/ BED 1 'G EXISTSEPrC 1 EXI G SEPTIC TANK TO BE,R£USED \ ABANDON IN PLACE BED INSPECTED "& _ PER CODE !S OPERArING�NORMALLY /OR 4 BR. 'S \ 1 \y ,ROP OJ 125Qg �5'EPTIC TANK ••• �-��SI=FEfr 3 .0� 11 NEW SERVICE LINE INSTALL FC p BY L£E REID SHED 05. �� MIN " Q o q 10' Q �•.• 0 EXIST'G EXIST'G WELL 38R HOUSE` \ LOT 26. 4 I "sem ��51. EXIST'G SEPTIC �; _ SHED �, �4 BR RESERVE,�ED S STEM INSTALL DCt7 25'Wx6OLFx0.5'ED,, 2.0 70 GARAG / `. SEE NOTES W I NEW SEOICE " ROPOS D 1 BR rFCO I DITION j�INS \ EXIST'G SEPTIC EXIST'G WELL > EXIST' E TIC- � % w j IS UED OR C SYRUCTION 9/11/07 / J/ PANNONE ING SVC, LLC REVISED Date P.O. BOX 102954 ANCHORAGE, AK 99510 PHONE 272-8218 09-0 -a, Scale *: '.*r� (907) FAX (907) 272-8211 1„=50' ... .. ... ..... P.I.D. NO 018-401-1 Steven R. Pannone % DeArrnoun S/D, Lot 4 PERMIT N0. Sw07xxxx / I<1,F'• CE 8149 'rte •09-11-oz•' William Higgins P❑ Box 191463 DPLANN s ,� �illEDy70p�p= Anchorage, AK 99511 sneer 1 of 2 SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON—SITE WASTEWATER DISPOSAL SYSTEMS. 2. ALL WORK SHALL BE IN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS. 3. SCOPE OF WORK: 4—BEDROOM HOUSE, NEW 1250 SEPTIC TANK, REUSE EXIST'G FIELD, ABANDON OLD TANK IN PLACE PER CODE. 4. GROUNDWATER IS NOT EXPECTED TO BE ENCOUNTERED DURING EXCAVATION, AS EVIDENCED BY THE SOIL TEST HOLE INFORMATION ABOVE 8 FT. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 6 FEET BELOW EXISTING GRADE, NOTIFY THE ENGINEER IMMEDIATELY. 5. THIS PERMIT IS FOR A NEW 12508 SEPTIC TANK ONLY AND TO OBTAIN APPROVAL TO OPERATE THIS SYTEM AS A FOUR—BEDROOM SYSTEM. EXIST'G BED, SIZED AT 882 SF AND BASED ON A SOIL RATING OF 190 SF PER BEDROOM, IS ADEQUATELY SIZED FOR A FOUR BEDROOM SYSTEM. RESERVE AREA IS SIZED USING THE CURRENT CODE AND APPLICATION RATE AND BASED ON A PERCOLATION RATE OF 16-30 MPI. 6. EXIST'G DRAINFIELD WAS INSPECTED AND FOUND TO BE ABLE TO ACCEPT 600 GPD AS REQUIRED BY CODE FOR A FOUR—BEDROOM HOUSE. DESIGN PARAMETERS (UPGRADE FIELD ONLY) NO. BEDROOM: 4 TANK SIZE: 1,250 gallon PERC. RATE: 15.2 MPI SOIL RATING: 0.5 gpd/SF APPLICATION RATE: 300 SF/BR AREA ROD: 1200 SF SYS. TYPE: BED 0.5' ED, 25'W MIN LENGTH: 48 LF USE: 6OLFx25'WIDE,0.5'ED,2.0' TO TOTAL AREA: 1500 SF ABBREVIATIONS CU COPPER DIP DUCTILE IRON PIPE TH TEST HOLE 'o o go FOUNDATION CLEAN—OUT T# TANK CLEAN—OUT NO. C# o� M# �w R. 1. �w 5 O i� eDo PeRP1, z S < 30M PVC U tNE125Og3=0A00 SEPTIC MIN.3LppE TANK s=0.0100 x r * a. EXIST'O BED- SEE PLANS FOR DIMENSIONS PROFILE DESIGN PARAMETERS (UPGRADE FIELD ONLY) NO. BEDROOM: 4 TANK SIZE: 1,250 gallon PERC. RATE: 15.2 MPI SOIL RATING: 0.5 gpd/SF APPLICATION RATE: 300 SF/BR AREA ROD: 1200 SF SYS. TYPE: BED 0.5' ED, 25'W MIN LENGTH: 48 LF USE: 6OLFx25'WIDE,0.5'ED,2.0' TO TOTAL AREA: 1500 SF ABBREVIATIONS CU COPPER DIP DUCTILE IRON PIPE TH TEST HOLE FC FOUNDATION CLEAN—OUT T# TANK CLEAN—OUT NO. C# CLEAN—OUT NO. M# MONITOR TUBE NO. R. 1. RIGID INSULATION LEGEND WATER LINE/ WELL RADIUS SS — ss — EXIST'G SEPTIC _U—ss— NEW SEPTIC CHAINLWK FENCE ISSUED FOR CONSTRUCTION 9/11/07 PANNONE ENGINEERING SVC, LLC REVISED DOte OF A� gs>t�) P.O. BOX 102954 ANCHORAGE, AK 99510 9/2/07 *�p' TH !y*�I/ PHONE (907) 272-8218 FAX (907) 272-8211 Scale NTS • • P.I.D. NO DeArrnoun S/D, Lot 4 018-401-13 I SfeveCE Pannone / Wiltiam Higgins(! �,•, CE 8149 •� j PERMIT N0. 9 11/07•.fir PD Box 111463 SW07xxxx • N= Anchorage, AK 99511 DESIGN sheet �i�\\fit=�� NOTES 2 or 2 01/25/2008 Municipality of Anchorage On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, Ak 99519 re: septic tank upgrade Permit # SW070247 Legal Description: lot 4 Dearmoun Site Address: 13800 Ervin Road Ladies and Gentlemen: I am submitting this additional documentation in support of my permit request filed by Pannone Engineering Services, LLC. I did the installation of the new septic tank, and was present during the entire time. I used a backhoe that I borrowed from my brother in law. I have installed septic tanks and entire systems before. In Anchorage and the Big Lake area. Thank you, William C.i ins P.O. Box 111463 Anchorage, AK 99511 ph# 242-8220 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION _ 825 L Street - Anchorage, Alaska 99501 Telephone 264.4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME PHONE ❑����� e . e _ �� �N�EW (?UPGRADE MAI 'iyJAXrss #:�wffuc�io 2 �5 LEGAL DESC IPTION A 20 ur S cY Uig LOCATION I NO. OF BEDROOMS -r Well-bsorption Dwelling PERMIT NO. DISTANCE TO: Uy E22 ManufacturerMaterial. - No. of compartments wF W Liq. capacity in gallons HOME ADE: Inside length Width Liquid depth d y DISTANCE TO: Well Dwelling PERMIT NO. J t�2 Oz F Manufacturer Material Liquid capacity in gallons O Well Foundation Nearest lot line PERMIT NO. m= DISTANCETO: LL Z No. of linesLength of each line Total length of lines Trench width Distance between lines F Z w inches Q IC 2 ~ Top of tile to 'n h r e Material beneath tile Total effective absorption area O inches w Length Width Depth PERMIT NO. C7 Q �/�r� Tye Crib diameter Total effective absorption area - / w hcn �---� '22LG W �Y DISTANCE TO: Well -/3 Buildin and tion Nearest lot line , J Class Depth Driller Distance to lot line PERMIT NO. J w � DISTANC Building foundation Sewer line Septic tank Absorption area(s) OTHER — PIPE MATERIALS SOIL TEST RATING f�10L1�8., INSTALLER C C o 10 FK _ REMAR S 6alAcilLam. / ((K A, I ^77,1 - ' Nd s I /lam! I ` f Io>JoTwtc r A � �O S MOA -q _� Irl 5 APPROVED DATE LEGAL -' 72-013 (Rev. 3/78) C1A" MUN I r= I 401- I -r-v Cl F= FANIC. "WF9C=iE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 'L' STREET, ANCHORAGE, AK. 99501 264-4720 WELL FitJ� a et i—E� I TE EWEFR PEEZM I T PERMIT NO. C 830454 � APPLICANT WILLIAM C HIGGINS BOX 111463 ANCHORAGE 99511 345-0302 LOCATION INSTALL WITHIN 10' OF TH2 LEGAL LOT SIZE 999999 SQUARE FEET TYPE OF SOIL ABSORPTION SYSTEM IS: TRENCH MAXIMUM NUMBER OF BEDROOMS = 3 SOIL RATING CSO FTrBR.)= 246 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: E] E F= _r"= :E: L l="C3 7r"= E fR f=j E: L_ DEP—r"= .4 THE LENGTH DIMENSION IS THE LENGTH CIN FEET) OF THE TRENCH OR DRAINFIELD. THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE ,SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION CIN FEET); THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVATION (IN FEET). REG 4 1 I AEC) = EPT I r TF=I"K I F= _ ::L biota CiF=fLLCjt-.IS} PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. --- TWn [ I t B PELT I C ! ARE RE=QU I FLEE? --- BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR A PRIVATE WELL OR 150 TO 200 FEET FROM A PUBLIC: WELL DEPENDING UPON THE TYPE OF PUBLIC: WELL. MINIMUM DISTANCE FROM A PRIVATE WELL TO A PRIVATE SEWER LINE IS 25 FEET AND TO A COMMUNITY SEWER LINE IS 75 FEET. WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN 30 DAYS OF THE WELL COMPLETION. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. F='E=RM I T E= P' I FZE E}Ef_-EME3ER :33 s --?Fe2 I CERTIFY THAT 1: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: 1 WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. 3: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE RESIDENCE IS REMODELED TO INCLUD MORE THAN 3 BEDROOMS. e t SIGNED:__ _ APPLICANT WILLIAM C HI CS S ------ ENLARGEMENT IF THE V4. 0 ISSUED BV_ • SOILS LOG , MUNICIPALITY OF ANCHORAGE ITMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION TEST 825 L. Street, Anchorage, Alaska 99501 _ 264-4720 SOILS LOG - PERCOLATION TEST PERFORMED FOR: V I 1 I I L-- 1.J I I I I Y lji I (� a' A I VQ LEGAL DESCRIPTION:_1-0� A , T 1-2N , Romp' V DATE PERFORMED: 4 83 S . `tcl-i rel, 33 Sett-) rd Ian 4 SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION TEST 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LLOJ//Gyyy��� PERCOLATION TEST /y/ DATEE J�(y PERFORMED: t� � / LEGAL DESCRIPTION: ,/ LIL 114 Vu y L SLOPE SITE PLAN FPT CD�-)Bi�'�NIG $IIT rTTI i (ak)5; H/Ifh Scl nd y `g r� ✓e SPA) 0ccasiorta- J S«nd �oLke1-g Ss�// p�b6/es Sarn.e r:obbie. s 5anc� . WAS GROUND WATER /l 0_ L ENCOUNTERED? Net Time Depth to Water _� O 7-N7,0 P lay/ E IF YES, AT WHAT ,� DEPTH? _/ ,//7 i ib Reading Date Gross Time Net Time Depth to Water Net Drop 7-N7,0 sr/q lay/ — ,sa — 10-5'1 ib . 3 • / s- THy W a TNZO W01 Ol-- I>: /O . 3q • /I Tho W;Z1 _ . Sb flPERCOLATION RATE /G. .z (minutes/inch) TEST RUN BETWEEN 'Z'S - FT AND 2*5 FT m • • ALASKA EIIUIROflmMAL COWROL SERUICES, IX Engineerinq & Environmental Studies Supplemental Soils SnYormation. w) �ca 33mock Subdivision T 1 'R 3±t - GX ol d M�riCtic�h Vii- 11R W LOT ( LOT LOT LOT TH TH TH TH DEPTH p DEPTH DEPTH aFET) OL Fro7-en (FEET) (FEET) 1 1 1 i 2 ISM 2 2 2 3 S'i I+y Sandy 3 3 4 13 Caravel 4 4 4 5 5 5 5 6 - 6 6 6- 7 7 7 fe�USQ� 7 8 g g 8 9 g 9 9- 10- 10 10 10- 11 11 11 11 12 12 12 12 13 13 13 13 14 14 14 14- 15- t5 I 15 15- 16- 16 16 16- 17- 17 17 17- 18 18 18 18 19 19 19 19 20 20 26, 20 1200 fest 33rd Avenue. Suite B • Anchorage. Alaska 99503 • (907) 276-1361 MUMCIPAUTY O 4� Development Services Department On -Site Water & Wastewater Section Parcel I . D.018-4.01-13 1 A rm� CHO RAS G�E Certificate of On -Site Systems Approval GENERAL INFORMATION Complete legal description Dearmoun Lot 4 Location (site address) 13800 Ervin Road Expiration Date Phone: 907-343-7904 Fax: 907-343-7997 Current property owner(s) Higgins Family Living Trust Day phone Mailing address Real estate agent 2. TYPE OF DWELLING: F-1 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 Day phone 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well IT] Private Septic 0 Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Dista Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ + ��� gU s Waiver Fee $ Date of Payment r yZ;ul Date of Payment Receipt Number 031 G Receipt Number COSA # 0 S C 2 113 2 LI Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Reliance on this report by another person is at their own risk. Pannone Engineering Services LLC highly recommends buyers hire their own engineer to evaluate this report. Name of Firm Pannone Engineering Services Address P.O. Box 1807 Palmer, AK 99645 Engineer's Printed Name Steven R. Pannone P.E. Phone (907) 745-8200 Date OF ALqs�> 6. DSD SIGNATURE ••••...• .• ' •• .•• System #1 Approved for bedrooms s ei%en ' . _ 'r,"ae ��� • CE 8148 System #2 Approved for bedrooms Disapproved@t..: Conditional approval for bedrooms, with the following stip`lakjGQPM(((pFr((/r���i ffy 0N-S1TE VV „ AND m J�o RO,�AA4 o J �\ JJJJ� CI '99 n r O\`\ 1��ilt v Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet COSA Checklist Legal Description: Dearmoun Lot 4 Parcel ID: 18-401-13 If more than 1 septic system on lot: COSA Checklist # 1 of 1 Structure served by this system 1 A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled UKN Total depth UKN ft Cased to UKN ft FE -Ml Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) 24 in. Date of flow test for COSA Static water level at beginning of test 115.4 ft. Comments B. TANK DATA Age of tank(s) 14 years Tank type/material "..4'Us " Measured operating fluid level in septic tank 48 FR Standpipes/foundation cleanout per record drawing Date of pumping 5/12/2021 D. ABSORPTION FIELD DATA Bed System Which system tested (date installed) 5,27==' © ALL standpipes present per record drawing Total measured depth from grade 5.9 ft (max) Measured depth to pipe invert from grade 1.5 ft (min) ❑ N/A — pressurized field 0 Monitor tubes go to bottom of effective. If not, state depth into effective 0 Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Comments/Deficiencies: COSA Checklist yellow sheet Well production at time of test 2.99 gpm Water storage tank volume N/A gallons Well disinfected for coliform test? ❑ Yes Fv� No 0 Coliform bacteria is Negative Nitrate mg/L © Nitrate less than MRL (ND) Arsenic ug/L ® Arsenic less than MRL (ND) Collected by PES Date of Sample C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Comments: Adequacy test date St0R02 Results ❑✓ Pass For 4 bedrooms Fluid depth prior to test 7 in Water added 600 gal New depth 8 in Elapsed time 200 min Final fluid depth 10 in Absorption rate 600+ gpd Any rejuvenation treatment (past 12 months) If yes, enter date E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' F/I Yes if No Community Sewer Manhole/Cleanout > 100' Yes if No ft 7 Yes if No Neighboring Tank > 100' Z Yes if No ft. Private Sewer/Septic Line > 25' C] Yes if No Absorption Field on Lot > 100' 7 Yes if No ft Holding Tank > 100' Yes if No Neighboring Absorption Fields > 100' Yes if No Animal Containment > 50'✓Q Yes if No 0 Yes if No ft if No ft F. ENGINEER'S COMMENTS Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' F/� Yes if No ft 0 Yes if No From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' Fv� Yes if No ft Surface Water > 100' ft ft ft ft M El Yes if No ft Property Line > 5' F/I Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' F/� Yes if No ft Private Wells > 100' Yes if No Water Main > 10' Q Yes if No ft Community Wells > 200' Yes if No Water Service Line > 10' FV� Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Q Yes if No ft if absorption field is under driveway comment below Property Line > 10' Q Yes if No ft Wells on Adjacent Lots: Water Main > 10' 0 Yes if No ft Private Wells > 100' 0 Yes if No Water Service Line > 10' Cj Yes if No ft Community Wells > 200' Yes if No Surface Water > 100' 0 Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet OF AL"s�a� C� 4THz� .... .. ... ft ft ft ft ------------ --o---- Q V OCA ! lA a3 3 -- ------------- I -- - - - --- 1N3W3Abd 30 35— a 00"996 M..00,ZO.00N C V_ O m O o } Zco oQ LO m U U)a u` v m Cf) J �C/)W o vain N M 0 Q1 O Q N � e N tn) vi J m N J U m -- � C. 1 o o m Cl) LL o v M Coi n O 0 F, / h \ m is � / C N ou Z0 o E'hZ ". 0'01 \ = 0 0 _o s.s.�� O'OZ O N CL N C O CF9 \ : T = m 8't t c m a o:. f s ) o�Q v r_ 2 y cs F p cu C: o t a �1J I Z'6Z j o m m r> O O 2L O i-+ h N V U co Y N U N N 2 � G " 00'.996 3110C 120 oOOS u ° E o o rn L G 107 eZ`107 \ �Z 107 / 5Z 107 W a v v y x