Loading...
HomeMy WebLinkAboutDEARMOUN LT 5I eoPmoun Lot 018-401 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page 1 of 3 www.ci.anchorage.ak, us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: 8W101219 PID Number: 018-401-12 Name: Fredrick Lewis Wastewater System: [] New [] Upgrade Address: 13740 Ervin Street ABSORPTION FIELD Phone: Number of Bedrooms: ~ [] Deep Trench [] Shallow Trench [] Bed [] Mound [] Other: LEGAL DESCRIPTION Soil Rating: Total Depth f .... riginal grade: 1,2 GPD~Ft2 12 Ft. Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: 5 Dearmoun 7.5 Ft. 4.5 Ft. Township: Range: Section: Fill added above original grade: Gravel Length: 0 Pt. 42 Ft. Well: [] New [] Upgrade Gravelwidth: Number of lines: I Distance between lines: 2,5 Ft. 1 - Ft. I Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material: Existing Private Pt. Ft. 378 Ft2 3034 PVC Driller: Date Drilled: Static Water Level: Installer: Date Installed: Pt. Red Dog Masonry 10/24/2010 Yield: I Pump Set at: Casing Height Above Ground: GPMI Ft. Ft. TANK SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other: T~To Septic Absorption Lift Holding ~ublic/Private Manufacturer: Capacity: From~ Tank Field Station Tank Sewer Line Anchorage Tank 1000 Ga,. Material: Number of Compartments: We, 120.9 142.8 56.0 Steel 2 SurfacaWater 100+ 100+ ~ / LIFT STATION Lot Line 66.3 50.0~ Size: Manufacturer: Gal. Foundation 63.0 84.5 "Pump on" level at: "Pump off" level at: J High water alarm at: in. in.I in. Curtain Drain N/A N/A Pump Make & Model Electrical Inspections performed by: Remarks: Existing 4 BE house demolished & replaced with new 3BE house. BENCH MARK Existing tank abandoned per code. Location and Description: Storage Barn Finish Floor Assumed Elevation: 100,0 Ft. Engineer's Stamp Inspections performed by: PANNONE ENG. SVC, LLC Dates: 1st 11/1/2010 2nd 11/3/2010 Development Services Department Approval Conditional Approval Date: ............ .' ..... ~ ~.,,.....,.~.,~..,,~...,..x..,..,..~.=...,~ ... ... Reviewed and approved by: w/' //~. e: ,~-.~._ ............ .~..~ ~ 0 E, ~ WELL(E) --- / i rap EXISTING ~ ~ SEPTIC AREA AREA DEVELOPED 1 0 1.8 EXISTING UNOOCUMENTED SYSTEM NOTWITHIN 100' ~ OF WELL ~ 154'0 ~ ~EXISTING FIELD IN FAILURE EXISTING 10009 ~ W TO BE R SEPTIC TANK ~ .~ ~v EUSED AS RESERVE ~ ~ ~ ~~ ~ 42LFx4.5' EDxSO"W, 12'TD WITH BALL VALVES ~ ~ /~ ~ ~ ~ 5~ A~ER TANK ~ N~ ~f ~ ~ ~ DC V C1 I I k 120.9 N~ N ~ ~ --~ ~.~ REP~CED WITH ~ ~~ NEW 5BP HOUSE A B C D E T2 102.2 80.0 EXISTING DC 107.6 86.5 HOUSE BV 116.6 97.7 ~ M1 114.8 96.4  M2 150.2 157.1 WELL (E) ~ C1 151.1 157.7 WELL 6.4 18.5 ...... ~ 2/~/~ RECORD DRAWINGS P.O. BOX 100217 ANCHORAGE, AK 99510 ~.~' 1"=50' NO PLAN ANCHORAGE. AK 99516 I~;¢¢~s,~._.--- ~ Sheet SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION WAS INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS. 2. ALL WORK WAS IN ACCORDANCE WITH THE A]-FACHED SPECIFICATIONS. 5. SCOPE OF WORK: INSTALLED NEW 1000 GALLON SEPTIC TANK AND NEW SOIL ABSORPTION SYSTEM. 4. NO GROUNDWATER WAS OBSERVED AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 18.0 FEET BELOW EXISTING GRADE, NOTIFY THE ENGINEER IMMEDIATELY. m2 98.5 OM 7.5 --5 -- 0.5' 4.5 ~.0 ~o. No ~roundwotor monitored (80.5) ~ o o ~o $ -- -- 98.5 FG & EG -- -- 98.5 86.5 TRENCH 42 LONG, 4.5' DEEP, 12' T.D. PROFILE DESIGN PARAMETERS ABBREVIATIONS LEGEND PRIMARY/RESERVE SEPTIC SYSTEM NO. BEDROOM: 5 (450 gpd) CU COPPER ~ W- WATER LINE/ TANK SIZE: lO00g DiP DUCTILE IRON PIPE WELL RADIUS PERC RATE = 1-5 MPI TH TEST HOLE SOIL RATING: 1.2 GPD/SF FC FOUNDATION CLEAN OUT ~ SS ~ NEW SEPTIC AREA RQD: 575 SF T~ TANK CLEAN OUT NO. SYS. ~PE: DEEP TRENCH 4.5' E.D. C~ CLEAN OUT NO. M[N LENGTH: 41.7 LF M~ MONITOR TUBE NO. R.I. RIGID INSU~TION USE: DCO DOUBLE CLEAN OUT 42 LF X 2.5' WIDE, 4.5' E.D., DV DWERTER VALVE 12' TD FS FLOW SPLICER TOTAL AREA: 578 SF NOTES: RECORD DRAWINGS p.o. BOX 100217 ANCHORAGE, AK 99510 Scole NTS FREDERICK LEWIS~'~'~"- cE 8~49 ..~ PERMIT NO. 13740 ERVIN ST ,~¢~... .,,¢~j 0SP101219 DESION DETAILS ANCHORAOE, AK gg516 I~{~o~¢{~ Sh~t Permit Number: Tax Code Number: Work Type: On-Site Wastewater Disposal System Permit OSP101219 01840112000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade Permit Effective Dates: October 11, 2010 to October 11, 2011 Design Engineer: PANNONE ENGINEERING SERVICE Subdivision: DEARMOUN Site Legal Address: DEARMOUN LT 5 G:2935 Owner/Address: LEWIS FREDERICK M JR & SUZETTE L 13740 ERVIN STREET ANCHORAGE AK 995163548 Site Mailing Address: 13740 ERVIN RD, Anchorage Lot Size in Sq Ft: 49500 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: The existing 4 bedroom house must be demolished before the inspection report will be approved. Received ,By: Date: Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, Alaska 99507 www. muni.org/onsite (907) 343;7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. Property owner(s) ?~'~'?-I(~l(' Mailing address 137~D ~-----~¢-VI/¢~ Site address ['~7~¢ ~--/~v'hAJ~- Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) Lot Size Sq. Ft. Zip Code Zip Code Number of Bedrooms Day phone THIS APPLICATION IS FOR ([~ all that apply): Absorption Field Septic Tank Holding Tank Privy Private Well Water Storage THIS APPLICATION IS AN: Initial [] Upgrade ~, Renewal [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signa~re of property / owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: (Rev. 11/05) Waiver Fees: Date of Payment: Receipt Number: Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com September 28, 2010 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program 4700 S. Bragaw Street P. O. Box 196650 Anchorage, Alaska 99519 Subject: DeArmoun S/D Lot 5 Septic System Permit Upgrade Request Ladies and Gentlemen: I am writing to request a permit to construct an upgraded septic system be issued for this property. The proposed systems will serve a new three-bedroom house. Currently the lot is developed. The existing house will be demolished and a new house constructed. The lot is served by a private water supply. The existing septic system is in failure and will be reused. A new drain field will be installed south of the existing field. The surrounding developed lots are served by private water systems. The private wells are located over 100 feet from the proposed soil absorption system. 1. Soils. A single test hole was excavated by A+ Home Services in September of 2010. See the attached soil log. Ground water was monitored for seven days. No ground water was monitored to a depth of 18 feet below ground level after the monitoring period. Bedrock was not encountered in the test hole. It is my opinion, based on the results of the percolation tests and overall soils appearance; an application rate of 1.2 gallons/day/square feet should be used, using a conventional wastewater treatment system. Soil Absorption System Design. See Design Drawings sheet 2 of 3 for design calculations. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and the existing drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 4. Topography: The average topography in the area of the proposed septic system is approximately 2 percent based on the survey information. The proposed installation will be greater than 50 feet from the shoulder of the steep slopes. 5. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that the review is complete and that there are no further comments is received from MoA On-Site Mailin6: P~O. Box S. 002~7~ Anchorage~ AK 995;i. 0-,O2S,;;' Physical: 61,5 East 82® A~,~e~ Cui1:e B6, Ancho~'age, AK 99505 Telephone: (907} 2'72,-,82L~.8 FAX: (907} 272~822,~ Page 2 of 2 Department, the note will be removed and "Issued for Construction" drawings will be issued. The proposed installation will not affect the future development of the surrounding or existing lots. There are no wells or septic systems within 100 feet of the proposed septic location. If you have any questions or concerns, please contact me at 272-8218. Sincerely, ........... Steven R. Pa~one, P.E. O~effCivil Engineer A~ac~ents: P~ysica~; 615 last 82nc~ Ave, Cuite B6~ Ancho~,"a~Se, AK 99503 Telephone: (907) 272-~82S, 8 [:.AX: (907) 272~82~S~ / \ ~ \ WELL (E) L'" EXISTING (ISTIN , UNDOCUMENTED ;YSTE i, NOT WITHIN 100' 1 05.0 OF WELL ~ EXISTING 10009 ~ 14/~___, ~ EXISTI"NG FIELD IN FAILURE --~---M- SEPTIC TANK ~ ~,~ ~ vv-~- TO BE REU,SED PROPOSEI~ SEPTIC1TANKO00g --x.--xNx.~ /.× .z~.~ A~ / / ~ INSTALL BALL VALVES ~ ~. ~ ..,~"/ ~ \ ~ LLI AFTER TANK~N ~~ J, ~ / % EXISTING __ SEPTIC AREA EXISTI ~ WELL (E) TO BE REPLACED WITH --M ~ NEW 3BP HOUSE EXISTING EXISTING HOUSE ° o WELL (E) -~ / '- ,__ NOTES: ENG LLC PANNONE o,~,, FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 ~?... ,~4~l~j~ 10/07/10 PHONE (907) 272-8218 FAX (907) 272-8211 ~.'..' ---/g':.l.~ll Scale  P.I.D. NO DEARMOUN S/D LOT 5 "'- anno~e ~'018-401-12 FREDERICK LEWIS '¢~ '~.'~':.,..' '-'~ .... .'"'~ ~ PERMIT ~¢~,'. CE 8149 .-~-~ NO. 1,5740 ERVIN ST ~/~;. ..C~ OSPLO1219 SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS. 2. ALL WORK SHALL BE IN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS. 5. SCOPE OF WORK: INSTALL NEW 1000 GALLON SEPTIC TANK AND NEW SOIL ABSORPTION SYSTEM. 4. NO GROUNDWATER WAS OBSERVED AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 18.0 FEET BELOW EXISTING GRADE, NOTIFY THE ENGINEER IMMEDIATELY. , SM/ ~M 7 5 6.0 BO. NO groundwoter monitored / SEPTIC TRENCH 42 LONG, 4.5' DEEP, 12' T.D. PROFILE DESIGN PARAMETERS A~VIATION~ L~O~ND PRIMARY/RESERVE SEPTIC SYSTEM NO. BEDROOM: 3 (450 gpd) CU COPPER ~ W- WATER LINE/ TANK SIZE: 10009 DIP DUCTILE IRON PIPE WELL RADIUS PERC RATE = 1-5 MPI TH TEST HOLE SOIL RATING: 1.2 GPD/SF FC FOUNDATION CLEAN OUT ~ SS ~ NEW SEPTIC AREA RQD: 575 SF T~ TANK CLEAN OUT NO. SYS. ~PE: DEEP TRENCH 4.5' E.D. C~ CLEAN OUT NO. MIN LENGTH: 41.7 LF M~ MONITOR TUBE NO. R.I. RIGID INDUCTION USE: DCO DOUBLE CLEAN OUT 42 LF X 2.5' WIDE, 4.5' E.D., DV DIVERTER VALVE 12' TD FS FLOW SPLICER TOTAL AREA: 578 SF NoT s: ~;~F ~17~ Date FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 ~__~.. PHONE (907) 272-8218 tAX (907) 272-8211 ~...~ 0~8-40~-12 FREDERICK LEWIS NO. DESIGN DETAILS ANCHORAGE, AK 99516 Sheet SOILS LOG - PERCOLATION TEST TEST HOLE SLOPE SITE P'L~ 1 -- OR ROOT MASS 3 -- BROVVN SM/GM SILT/SAND L~LJ 4-- 5 TH 10 -- TO BE REPLACED WITH NEW 5BR HOUSE 11 --J POORLY ~41 ~ GRADED ~'/ GP/SP GRAVELLY ~ .~/ 12 -- SAN D W/SOME , SILT (GRAY) 15 -- WAS GROUND WATER SLOPE 14 --, ENCOUNTERED? N 15 -- IF YES, AT WHAT TH 16 -- DEPTH? -0-' X 17 -- DEPTH TO WATER AFTER MONITORING? -DRY- 18 DATE: 9/27/10 BOH I WATER DATE PERFORMED: 9/10/10 READING DATE I CLOCK NET TIME LEVEL NET DROP TIME READING I 9/10/10 10:36 --- 3.25 --- 2 10:46 10 MIN 5,68 2.43 3 10:47 -- 3.25 --- 4 10:57 10 MIN 5.61 2.36 5 10:58 -- ~ 3.25 --- 6 11:08 10 MINI 5.54 2.29 PEROLATION RATE 4.4 (min/inch) PERC HOLE DIAMETER 6 inches TEST RUN BETWEEN 5 FT AND 6 FT COMMENTS: Test hole excavated by A+ HOME SERVICES. Prec hole was presoaked. Test run for one hour. Last 3 readings reported PERFORMED BY: Steven R. Pannone~ P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. ~'~-'~-'~"--'~-%'~.~,~ ,. D a t e NO-rEs: PANNONE ENG SVC, LLCi' 10/07/10 FOR CONSTRUCTION P.O. BOX 102954 ANCHORAGE, AK 99510 PHONE (907)272-8218 FAX (907)272-8211 ~'o~.w._' %..,~i~i, Scale  P.I.D. NO DEARMOUN S/D LOT 5 -.018-401-12 FREDERICK LEWIS "~~"'~'n'o~;'~ PERMIT NO. fl, ~_". CE 8149 .'.'4~- ~ 13740 ERVIN ST *~i?~;-. .'~'~',~ OSP101219 SOILS LOG ANCHORAGE, AK 99516 CLOCK WATER READING DATE TIME NET TIME LEVEL NET DROP READING I 9/10/10 10:36 --- 3.25 --- 2 10:46 10 MIN 5,68 2.43 3 10:47 -- 3.25 --- 4 10:57 10 MIN 5.61 2.36 5 10:58 -- 3.25 --- 6 11:08 10 MIN 5.54 2.29 ~UNICIPAL~TY OF ANCHORAGE~ Hee° ~and Environmental Prote( Fourth Floor West 825 L Street Anchorage, Alaska 99501' 264-4720 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM oc ,ON c SEPTIC TANK: DISTANCE I FROM WF'LL J 0C) ,.~ MArIUFACTURER ~t.~..u,~.~" MATERIAL INSIDE LEt~GTH INSIDE WIDTI4 LIQUID DEPTH NUMBER OF LIQUID CAPACITY J~Q~ GALLONS. TILE DRAIN FIELD:~''~''pJHS~'''''cl'~ DISTANCE FROM WELL J00 J~ FOUNDATION '~O~ NEAREST LOT LINE ~ I~ TOTALoF LINELENGTH~ I ~ of Lines J DISTANCE BETWEEN LINES ~/~ TRENCIt WIDTH ~ IN. TOTAL EFFECTIVE ABSORPTION AREA ~ ~ SQ. FT. LEITH OF EACH LINE -- DEPTil OF FILTER ' OEPTIh TOP OF TILE TO FINISII GRADE ~ MATERIAL BENEATH TILE ~ IN. ABOVE TILE ~ IN. SEEPAGE PIT: Log Crib Rings BUILDING FOUNDATIO~I DIAMETER OR WIDTH Crib Size: OIAMETER NEAREST LOT LINE LENGTH DEPTH DEPTH DISTANCE FROM: TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) WELl,. Well Class:~. Depth: Well Distance To: Lot Line~ Bldg: ~ql Sewer,Line: Pipe Materials: ~_~L ,~j~'~--'- ~ of Bedrooms: Installer: Remarks: ,~:~.t~ APPROVED · 'o DEPARI'MEN[ O~'-x-LAL'TH RND EN'¢IRONMENTRL P,~'-~ECIlON k..~..4-.~ ' ~ · 82~ ~L~ .IREEI', MNCHORNGE, AK. 99b -~ PENPI[T NO. ( 777~5 ) ~ ~b 'LEGRL LO1 5 bEHRMOUN SUB . LOT SIZE 4~5~ 5QURRE FEET ]YHE OF 501L RBSORBT]ON S~STEM I5: TRENCH ~'~ ~,XI~IU~I NUPI~ER OF BEDRO0~,S = ~ SOIL RHTINu (SQ FT/B~)= ~' ~ HE REQUIRED 51ZE OF.THE SOIL RBSORPTION SYSTEM IS: ~ DEP'I-H= ::1_0 LF--r4G]-H= --<--< GRRVEL DEPI'H= 6 [HE LENGIH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRINFIELD. ]HE DEPTH OF 8 TRENCH OR PI]' IS THE DIS]BNCE BETWEEN THE SURFRCE OF THE GROUND HND THE BOTTOM OF- ]HE EXCRVRTION (IN FEET). 1HERE 1S NO SET WIDTH FOR TRENCHES. ]HE GRHVEL DEPT'H IS THE MINID1UM DEPIH OF ORRVEL BETWEEN THE OUTFRLL PIPE BN'J 1HE BOTTOM OF THE EXCHVHTION (IN FEET). t~EQU I RED SEP1- I C ]]:11'-.11< $ I ZE: '1000 ISFILLOhI$ PRI3KFIt_~E PLFIr-~]- OPT I ON !H PHCKROE PLRNr MRY BE INSTRLLED RT THE PERMITTEE"S OPTION SUBJECT TO THE FOLLOWING CONDITIONS: 1. EITHER R CLRSS I OR II NSF RPPROVED PLRNT MRY 8E INSTRLLED. 2. H CONTINUOUS MRINTENRNCE 8GREEMENT IS REQUIRED. IF R MRINTENRNCE RGREEMENT IS NOT KEPr CURRENT YOU WRY BE REQUIRED TO ENLRRGE THE SOIL RBSORPTION SYSTEM RND?OR YOU MRY BE SUBJECT TO PROSECUTION. ]'NO ( ;;' ) I NSPECl- ION$ FIRE REI~U ! RED BRCKFILLIN~3 OF HN'¢ SYSTEM WITHOUT FINRL INSPECTION AND APPROVHL BY THIS DEPRR]~IENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DI5IHNCE BETWEEM H WELL AND ANY ON-SITE SEWRGE DISPOSRL SYSTEM IS 100 FEET FOR H PRIVRTE WELL OR 200 FEET FOR R PUBLIC WELL. O]HER REQUIREMEMTS HHY HPPL~. SPECIFICRTIONS RND CONSTRUCTION DIBGRRPIS BRE HVHILHBLE lO INSURE PROPER INSTRLLRTION. EXPIRES DECEMBER ~l- ~77 I CERTIFY THRT 1:. I HPI FHPIlLIHR WITH THE REQUIREMENTS FOR ON-SITE SEWERS RND WELLS RS SET FUNI'H BY THE MUNICIPRLITY OF RNCHORRGE. 2:1 WILL INSTRLL THE SYSTEM IN RCCORDBNCE WI]H THE CODES. ~: I UNDER5]RND THRT THE ON-SITE SEWER SYSTEM MRY REQUIRE ENLRRGEMENT IF THE RESIDENCF-~ IS REMODELED TO INCLUDE MORE THRN '~ BEDROOMS. S I GNED: ....... RPPLICHNf JRNET RUSSELL .... 0 August 23, 1977 R&M No. 751221 Richard Besse 1360 E. 71st Anchorage, Alaska 99502 Subject: Soil Investigation for Sanitary Sewer System, Lot 5, DeArm~un subdivision, Anchorage, Alaska Dear Mr. Besse: At your request of August 18, 1977, we conducted a subsurface soils investigation at the proposed location of the sanitary sewer system on the subject lot. The investigation complied with those procedures required by the Municipality of Anchorage Department of Health and Environmental Protection. This investigation, which was accomplished on August 22, 1977, consisted of a test hole drilled to a depth of 17.5 feet below the existing ground surface. The test hole was sited according to your instructions and its location is shown in attached Drawing A-01. Drilling was accomplished with a rotary drill rig using continuous flight solid-stem auger with an outside diameter of 6 inches. A sample was taken at the depth shown on the soils log in Drawing A-01. The sample will be held in storage in our lab for approximately six months. In addition, all material brought to the surface by the augers was continuously monitored by an experienced engineering geologist. The topography at the drilling site is generally rolling. At the time of the investigation the site had original vegetation consisting of grass. The top of the test hole was located at original ground surface. The soils encountered in the bore hole are shown in the test hole log in Drawing A-01. The symbols used in Drawing A-01 are explained in Drawings B-01, and B-02. This log displays specific conditions encountered at the test location. However, subsurface conditions may vary in other parts of the lot without any apparent surficial evidence of the change. Groundwater was not encountered in the test hole. Bedrock was not encountered. At the time the hole was drilled seasonal frost was not present and permafrost was not encountered. Based on the visual classification of the soil and the requirements set forth by the Municipality of Anchorage, a percolation test was not necessary within the test hole on the subject lot. August 23, 1977 Mr. Richard Besse Page -2- We appreciate this opportunity to be of service to you. Please contact us if you have any questions concerning this letter or if we can be of additional service. Very truly yours, R & M ~ONSULTANTS, INC. Seni~ Geologist GAS/gld Attachments: Drawings A-01, B-01, B-02. Lot 5, DeArmoun Subdivision Anchorage, Alaska T.H. 5~01 75' J Not to Scale Distance shown are approximate and have not been measured by surveying methods. 8-23-77 ..0Jcc* No 751221 scaL~see above O.A*,N~ ,O.A_01 R&M CONtSULTANTG, INr' TEST ROLE LOG Scale: 1"=3t ORGAt~IC SILTY SAND(SM+PT) Brown, Trace Gravel -- 4.5' GRAVEL W/TRACE SILT At~D SAND )GP-~t) Slightly Moist, Brownish Grey m m m m m SAt]DY GRAVEL (('~rl) Grey 13.0' 17.5' T.D. Groundwater was not encountered. This log depicts subsurface soils observed within the test hole at the location shown. See Drawings B-01 and B-02 for explanation of symbols. LOCATION SKETCh[ At[D TEST IIOLE LOG RI Ct5%RD BESSE AHCHORAGE, i~J2%S F,3% SOILS CLASSIFICATION! CONSISTENCY AND SYMBOLS CLASSIFICATION: Identification and classification oE the so~ is accomplished in accordance with the Unified Soll Classification System. Normally, the grain size distribution determines classification of the soil. The soft is defined according to major and minor constituents with the minor elements serving as modifiers of the major elements. For cohesive soils, the clay becomes the principal noun with the other major soll constituents used as modifier; i.e. silty clay, when the clay particles are such that the clay dominates soft properties. Minor soil constituents may be added to the classification breakdown in accordance with the particle size proportion listed below; i.e. sandy silt w/some gravel, trace clay. no call - 0 - 3% trace - 3 - 12% some - 13 - 30% SOIL CONSISTENCY - CRITERIA: Soll consistency as defined below and determined by normal field and laboratory methods applies only to non-frozen material'. For these materials, the influenc~ of such factors as soll structure, i.e. fissure systems, shrinkage cracks, sllckensldes, etc., must be taken into consideration in making any correlation with the consistency values listed below. In permafrost zones, the consistency and strength of frozen soils may vary significantly and unexplainably with ice content, thermal regime and soll type. Cohesionless N*(blows/ft) Relative Density Loose 0 - 10 0 to 40~ Medium Dense l0 - 30 40 to 70% Dense 30 - 60 70 to 90% Very Dense - 60 90 to 100% *Standard Penetration "N": Blows per foot of a 140-pound hammer falling 30 inches on a 2-inch OD split-spoon except where noted. Cohe sive T- (tsf) Very Soft Soft Stiff Firm Very Firm Hard 0 - 0.25 0.25 - 0.5 0.5 -1.0 1.0 - 2.0 2.0 -4.0 -4.0 DRILLING SYMBOLS WO: Wash Out WD: WL: Water Level BCR: WCI: Wet Cave In ACR: DCI: Dry Cave In AB: WS: While Sampling TD: While Drilling Before Casing Removal After Casing Removal After Boring Total Depth Note: Water levels indicated on the boring logs are the levels measured in boring at the times indicated. In pervious unfrozen soils, the indicated elevations are considered to represent actual ground water conditions. In impervious and frozen so,~s, accurate determinations of ground water elevations cannot be obtained within a limited period of observation and other evidence on ground water elevations and conditions a e re ed. . ' Engineering 8~ Geological Consultants Inc. · .c.o.~e ,*,,,~.K, ALASKA JUNr*U GENERAL NOTES ,-,-,2 I.cAL Iow. I -,o ', Iow .o. B'OI MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Date April 16, 1985 - GENERAL INFORMATION (a) Legal Description (include lot, block, subdivision, section, township, range) Lot 5, De Armoun Subd.; ~ec.28, T12N, R3W, S.M. Location (address or directions) (b) Applicant Name Bert McQueen Telephone: Home 345-3983 Business 561-1092 Applicant Address .~t, ~,./~R~ ~lw,_ ~.n~-~n~g~.; /IF 99_503 (c) Applicant is (check one): Lending Institution r-I; Owner/builder ~'?; Buyer IF'I; Other I'1 (explain); (d) Le~ding Institution FedAlaska Credit Union Address 8m & I St.~ Anehorase, A~ 99501 (e) Real Estate Company and Agent N/A~ Telephone 276-1Oll Address '(f) Telephone Mailthe HAAtothefollowingaddress: Hold for pickup TYPE OF RESIDENCE ' Single-F. amily[~ Multi-Family[] Number of Bedrooms Three Other WATER SUPPLY Individual Well [] Community D Public [] Note: If cum munity well system, must have written confirmation from the State Department of Environ mental Conservation ' attesting to the legality and status. . .... "' 4. SEWAGE DISPOSAL Onsite~)~ Public[] Community[] Holding Tank [] Note: If community well system must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 12-o=5 (11,84) ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION AS certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate ..... for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained 'from the Municipality of Anchorage files and from my Investigation and inspection, the on-site water supply and/or · wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Alaska Soil Testing and En~ineeringTelephone Address 61OO A El_. Ar. chora_~e~ AK qqS02 Daie ST85-260 561-7453 Approved f6r'---~ Approved ,,~,X"~y~",~,~ bedrooms by _ ~' Date Disapproved Conditional Terms of Conditional Approval CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal arid state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Pan~ 2 of 2 MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 264-4720 HUNICSPAU'~Y OF D~PT. OF HEALIM & Legal Description: Lot 'APR WELL DATA Well Classification ?r:Lvate I, A, B, C, D.E.C. Approved (Y/N)RECEIVED M. Well Log Presf~nl (?N) . Dale Compleled Uz'~nown Yield 450 gal/da[ J~er 24 hr l~O'(Insp. R~t) Unkncwn(130.~¢~ .- . N/A, drawdown teat Tota~ Deplh gased to ~prn ct ~roufing Static. Water Level 120 ft. Pump Set At l~O ft. Casing Height Above Ground 14" (?2"above basemen,~,anitary Seal on Casing (Y/N) Y floor) ' Electrical Wiring in Conduit (V/N) N(We]:l In case- Depression Around Wellheed (Y/N) N(Well in b~$ement) merit) Separation Distances from Well: To septic/Holding Tank on Lot ll4 ft. ; On Adjoining Lots 1OO ft. To Nearest Edge o! Absorplion Field on Lot 126 ft. ; On Adioining Lots 1OO ft. To Nearest Public Sewer Line 100+ ft. To Nearest Public Sewer C;eanout/Manhole 1OO+ ft. To Nearest Sewer Service Line on Lot 10 ft. Water Sample Collected by Mark Holumt P.E. ; Dale 4-1~5-$~ Water Sample Test Results Satiefactor~r Comments Well loE. is not on file with state or munici~ality. B. SEPTIC/HOLDING TANK DATA Date Installed Standpipes (Y/N) Y Air-tight Caps (Y/N) Depression over Tank (WN) N Pumping/Maintenance Contract on File (Y/N) Holding Tank High-Water Alarm (Y/N) Separation Distances from Septic/Holding Tank: 4-9-77 Size 1000 ~*al. No. of Compartments 2 Foundation Cleanout (Y/N) Date Last Pumped _~ ") ~. - ~'"~' ; for Temporary Holding Tank Permit (Y/N) N/A To Water-Supply Well 114 ft. To Property Line 58 f~;. To Water Main/Service Line 70 ft. Course ~.00+ ft. To Building Foundation' ' 70 ft. To Disposal Field 7 ft. To Slream, Pond, Lake, or Major Drainage Commems Page 1 of 2 72-026(11/84) C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata130 ft2/bdrm(Insp· Rpt)Type o! System Design Date Installed 4-9-77 Width of Field ~6 inches Square Feet of Absorption Area Depression over Field (Y/N) Results of Lest Adequacy Test 448 ft2 SatisfagtOrX Separation Distance from Absorption Field: To Water-Supply Well 1OO ft. To Building Foundation 82. ft. Lot N/A To Water Main/Sen/ice Line 82 ft. To Stream/Pond/Lake/or Maior Drainage Course To Driveway. Parking Area. or Vehicle Storage Area Septic Tank and Trench Length of Field ~6 ft. (Insp. Rpt. ) Depth of Field 8.5 ft. Gravel Bed Thickness 4 ft. Standpipes Present (Y/N) ¥ Date of Last Adequacy Test 4/1~-16/8~ To Property Line 20 ft. To Existing or Abandoned System on ; On Adjoini6g Lots 156 ft. To Cutbank (if present) 1OO+ ft, 100+ ft. ' 30 ft. Comments D. LIFT STATION Date Installed N/A, Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for ~lectrical Codes (Y/N) Dimensions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA Comments "Check Permitted Bedroom Rating Against HAA Request" Receipt No. Date of Payment Amount: $ I certify thai I have checked, verified, or conformed to all MOA and HAA gui?elines in effect on the date of this inspection. Sign Date 4-16] '~ Soil Testing & EngXMOANo. ST8~ 260 Company ~ ~' ~~' .;.~ Page 2 of 2 72-O26 ( I 1,84) ALASKA SOIL TESTING AND ENGINEERING 6100 A Street, Anchorage, Alaska 99502 (907) 561-7453 Location: Type: Address: Client: Date ~4-13-85 4-14-85 4-16-85 Comments: Conclusion: Performed by: Adequacy Test Lot 5, De Armoun Subd. Septic Tank and Trench (See Installation Rpt., Attached) 13740 Ervin St. Anchorage, AK Bert McQueen, 524 E. 48~ Ave. Anchorage, AK 99503 Time Quantity of Depth Below Depth Below Water Added to Grade of Water Grade of Water Trench Level in Level in Trench Septic Tank (Gal) (Inches) (Inches) 11:33 am O 98 ~/~ 88 7/8 11:50 67 96 1/4 88 3:07 pm 256 93 83 3/4 5:20 486 90 1/2 81 3/8 5:28 " 90 3/4 81~3/4 7:21 " 93 3/8 84 9:59 am " 97 3/4 88 5/8 11:42 0 97 7/8 88 5/8 2:36 pm 170 94 3/8 85 1/4 5:54 467 91 1/4 87 1/8 7:27 " 93 83 3/4 8:51 am " 96 1/8 88 9:35 0 97 1/8 88 9:41 100 94 5/8 85 1/2 9:46 200 90 1/2 80 10:05 300 87 3/4 77 3/4 lO:2O 450 84 1/2 75 1/2 10:30 " 86 76 1/2 12:40 pm " 91 3/4 82 1/2 2:52 " 94 84 1/2 5:41 " 95 1/8 86 10:45 am " 99 7/8 90 1/2 The septic system was in use prior to and during the test. The absorption rate of the trench exceeds the minimum rate of 450 gal/day for the three bedroom si~l, family dwelling. Mark Holum, PiE. ST85-260 DATE RECEIVED · { · INSPECTION APPOINTMENTS ,.-~. , INSPECTOR INSPEC~ ~~ INSPE~~ ' MUNICIPALITY OF ANCHORAGE MUNIOPAU~ OF AN~O~GE t~ DEPARTMENT OF HEALTH & ENVIRONMENTAL PROT~TIO~EpL OF HEALTH ENVIRONMENTAL SANITATION DIVISION JUtl [ 1 19B1 Tele~one ~7~ ~ LENDING INSTITUTION ~E MA%LING ADDRESS ~ STREET.~CAI'ION 6. TYPE OF RESIDENCE NUMBER OF~BEDROOMS I'-I One I'-] Four ~ SINGLE FAMILY [] Two [] Five [] MULTIPLE FAMILY ,~ Three* [] Six [] Other 7. WATER SUPPLY ,~ INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled r-I COMMUNITY since June 1975. For wells drilled prior to that date, give well [] PUBLIC UTI LITY depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM [~ INDIVIDUAL/ON-SITE** ,YEAR ON*SITE SYSTEM WAS INSTALLED. [] PUBLIC UTILITY NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. ~ . THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS , Y I--I SINGLE FAMILY [] ONE [~THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER []INDIVIDUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY Connection Verified INSTALLER []SepticTank or []HoldingTank Size: If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4. DISTANCES Septic/Ho~ding Tank IAbsorption Area JSewer Line I Nearest Lot Line WELLTO: I I I Absorption Area to nearest Lot Line 5. COMMENTS APPROVEDFOR '5 BEDROOMS [] CONDITIONAL APPBDVAL {letter must accompany certificate} [] DISAPPROVED DATE d BY~ 72-010 (Rev. 6/79) ~% DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTEC~[ONL'.~TAL ENVIRONeENTAL REQUEST FOR ~PROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all parts on paoe 1. Incom~ete requ~ts will not be procam~], R~ el~ ~ (tO) days f~' pm~esin9. PHONE S. LENDING INSTITUTION JPHONE MAILING ADDRESS 4. REALTOR/AGENT MAILING ADDRESS JPHONE 5. LEGAL DESCRIPTION STREET LOCATION TYPE OF RESIDENCE SINGLE FAMILY [] MULTIPLE FAMILY NUMBER OF BEDROOMS r"l One I--I Four [~] Two r-I Five ~ Three [] Six [] Other 7. WATER SU~LY INDIVIDUAL* [] COMMUNITY [] PUBLIC UTILITY "'8, SE~I~AGE DISPOSAL SYSTEM INDIVIDUAL/ON-SITE** [] PUBLIC UTILITY · ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. For wells driUed prior to that date, give well depth (attach log if available.) J <~) I "1 f individual/on-site, give installation date If system is over two (2) years old an adequacy ' " test ~s reqmred by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATEE~ 72-O10(3/78) ' · --*-.i~ THIS SIDE FOR OFFICIAL USE ONLY INSPECTION APPOINTMENTS TIME TIME DATE INSPECTOR DATE INSPECTOR DATE RECEIVED' TIME DATE INSPECTOR DIRECTIONS: 1. TYPE OF RESIDENCE [] SINGLE FAMILY [] MULTIPLE FAMILY 2. WATER SUPPLY [] INDIVIDUAL [] COMMUNITY [] PUBLIC UTILITY Connection Verified 3. SEWAGE DISPO~;AL SYSTEM [--IINOIVIDUAL/ON -SITE []PUBLIC UTILITY Connection Verified [] Septic Tank or [] Holding Tank Size: //.)~L) If Tank is homemade ire dimensions: YPE OF TANK TOTAL ABSORPTION AREA 4. DISTANCES WELLTO: Ab~ption Aree to neerest Lot Line NUMBER OF BEDROOMS [] ONE [] THREE [] FIVE [] TWO [] FOUR [] SIX PERMIT NUMBER [] OTHER DEPTH OF WELL DATE DRILLED LOG RECEIVED IPERMIT NUMBER DATEINSTALLED INSTALLER SOILS RATING MANUFACTURER Lot Line ~ APPROVED FOR BEDROOMS [~'~'CONDITIONAL APPROVAL (letter must acco~ny certificate) 'U:a~O~SAPPRO~ DATE-- BY (Titlel LEGAL DESCRIPTION ~ · Mr. Dan Rapalee Local Representative Veterans AdministratiOn P. O. Box 1~99 ~chorage, Alaska 99501 SUBJECTs Sewage Facilities Serving Lo~ 5, Dearmoun Road Subd. - Ho~e of Mrs. U. D. Holm l)~ar Mr. Rapalees ~ personnel of the Creater Anchorage Area Borough Health Department have made recent inspections o£ the sub~ect location. In or,er for the ~ewage system to meet our requirements for a three ~B~l~Om home, it will be necessary to install a 1OOO gallon septic ~X ~I1 CO~:~[~ with the presently existing cesspool. ~ls q / ~' _l,~' / Sincerely, / ~edlcal Director BYI ,, David ~. Harkness, R. S. ,, .--- S~ltarian ~;r. ~mn RaDaloe Local Veter~ ADministration A~chcra~, SUbJEcT: Installation Of Sewa3e racllitle: Servln2 Lot 5, I~Ar~oun Road SuLdlvl- sion, {{o~e of }frs.U.A. HOD-. Personnol of ~he Gr~-.ater /unchora~e Area Borou~.h }fcal~h D~partr, cnt ha~. ~ade a recent inspection of the subject sewage faci~ltlc$. by this office on Juno 3.3, 1969; ~hcrcfore, ~ktnE th9 sewage end Water fa¢llltle~ sf~rroved Ly thl~ offl¢.. Elncorsly, DAVID h.L. " ' DU.,CA. , ){.D. S~dlcal Director Dii ,' rn cc-' /:r. Phillips ~ani~arlan