HomeMy WebLinkAboutFOREST RIDGE BLK 1 LT 8 Municipality of Anchorage Page I~of '~' DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: ~c,,J .- ~ ~o'~.~O PID Number: et'/ - II [ - ,ama: ~O,.o~'t ~'VI~-~2~-~ A'~:'T,~y~,<.E'"" Wastewater System: ~ New I-I Upgrade '~'~ ABSORPTION FIELD Phone: ,~l~l~ _ ~oZ~l~,'~ INo'ofB~.~OOm$: r"l Deep Trench i'lShaIIowTrench I-IBed ~.Mound r'lOther Total Depth from original grade: LEGAL DESCRIPTION so~,,,t~,g: O.E, ~,~,sq Ft =' (^,,~o Subdiviaion: 3epth to pipe bottom from original grade: Gravel depth beneath pipe Township: I Range: I Sectio.: Fill added aflove original grade: Gravellength: C~ WELL: I~ New r'l Upgrade Gravel width; .~ I Number of lines: Class,fication ~Private, A.B.C): Total Depth: Cased TO: Total absorption area: Pipe materiel: SEPARATION DISTANCES [] Septic [] Ho~ing ~.S.T.E.P. Surface Wa~er I~O~' ',~'~Ooh- '--' -- LIFT STATION Remarks: ~o~ ~*,~ 7e 6~ ~O BENCHMARK ~.0 Alask~ Department of HeaVy,man ~e~ces approval ~:~h,~?~ Reviewed and approved by:~~ ~, ~~ate: ~-~-~7 PER~IT NO. SW960330 PAGE 2 O~' 3 Hunlcipatrl;y oF' Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650e, Anchor,,ge. A(aske, 99519-6650 e Te(ephone: 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LOT 8, BLOCK 1, FOREST RIDGE S/D PJ.D. No. 017-115-07 NI WOODHAVEN AVE. 10' UTIL. ESMT. .~.o ~f'-NEW PRESSURIZED ,.~,~/ TRENCHES · ,,X,,~',,X';, '% ,_ ......... %, '%",X,",, ....  ,'-ZZZZ-- -Z3 .~. ,..~,,ALT. SITE-' SAND FILTER~ ~o ~ ~'~' 1500 GAL S.T.E.P. SYSTEM ST1 3~.0' B 47.0' ST2 57.0' 48.0' MH1 I 59.5' 48.5' MH2 J 58.0' 60.0' MT1 J 50.5' 60.0' MT2 I 52.5' 46.5' MT5 I 64,5' 68.0' MT4 J 66.5' 57.0' MT5 89.5' 82.5' MT6 1154.5' 22.5' MT7 I 86.5' 89.5' MT8 1150.0' 127.0' MT9 87.5' 99.0' MTIO 133.0' 135.5'I PERMIT NO. SW960330 PAGE 3 OF 3 MunJcJpatJ%y oF Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONHENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 ON-SITE WASTE'WATER DISPOSAL SYSTEM AND/OR WEM. INSPECTION REPORT U!:C,U, LOT 8, BLOCK 1, FOREST RIDGE S/D Pig. No. 017-I15-07 N.T.S. CRADE N.T.S. IT5 = MT9 = 103.6' 101.4' MT7 101.9' y--FINAL ~,oo. ,o~.~ · ? x: ,x/~:~I ~.~,. ~.o.,,. P.01 SEP-'0~-1997 15:19 COLOHY BUILERS, INC. "9'/ t~:~ · INSPECTION REPORT i' MUNICIPALiITY OF ANCHORAGE, BUILDING SAFETY O~qSION 3600 EAST TUDOR ROAD -. IN3PECT:ON: VO;.C.E 563",7"4~4 _I_N.~p-~CTIO~; FAX l~tl)7134,?~.8~35 INFO:. 343d!211 CO/~MENT~ or DIRECTIONS: ' CO~E~ION3 ~SEN~AL A~ ~P~tED BELOW WILL RE.E~UINE AT N~ IN~PEC~ON [ ] CO NOT CONC~L UN~L RE~SP~C'~0 WNi~N CORI~ECTIQNa AR.c MADE PLEASF CALl FOR RI[INSPECTION .; L(/CATfON OF WELL STATE OF ALASKA DEPARTMENT OF NATURAL RESOURCES DIVISION OF MINING & WATER MGMT :WATER WELL'~RECORD LOCATION/SKETCH: DEPTHS MF. ASURED FROM:Dcasing top r-)ground surlace ~OREHOLE DATA: Depth Materiel Type end Color From To WELL OWNER: 0 STATIC WATER LEVEL: ft bel0w/~ top Of casing Date: AL ground surllce METHOD OF DRILLING:,,~ e~r rotary ~-I cable tool' [] other USE OF WELL: ~ domestic, r-I irrigation []-1 monitor · ~1 public supply F'I other ' CASING Casing typea WELL INTAKE OPENING TYPE.v,~ open end I~ screened [] perforated r'-i open hole RECEIVE SEP 8 1997 Depths of openings: Io ft SCREEN TYPE: Diem: In~ Slot/Mesh Size: - " GRAVEL PACK TYPE: Volume used: GROUT TYPE: Depth: from DEVELOPMENT METHOD: Duration: Depth to 1 LEVEL AN£ *IELD: (t after Dept. Health & n Services PUMP INTAKE DEPTH: ft Horsepower: WELL DISINFECTED UPON COMPLETION'~ YE~ [] CONTRACTOR INF ORMATI~.N: R[MARKS. -- _ '" ,/I ~.,,f/~ . I *'-' ' - ~, . W.,TE co. ,~neture o o'!," orlze espF e/'~t&uve ~e' -/e~'~ rk.~ OF MINING & WATER MGMT 3601 C St. $~lte S00 ANCHORAGE AK Phone (9071269-SS39, Fex (907J562.1384 ft 1~) it o CoPy MUN~CIPA~.ITY 0~ ANCHORAGE DW. PARTM~NT 0~ HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ~-- ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW960330 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:NORCOL INVESTMENTS OWNER ADDRESS:2340 LOREN CIRCLE ANCHORAGE, ALASKA 99516-2375 PARCEL ID:01711307 1 LT 8 LEGAL DESCRIPTION: FOREST RIDGE BLK LOT SIZE: 167167 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ..ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: DATE ISSUED:10/02/96 EXPIRATION DATE:10/02/97 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: DATE: DA E:/O-- 2 -?¢ ROBERT SHAFER. P.E. ROGER SHAFER. P.E. I~ay 18, 1994 CIVIL ENGINEERS (907) 694-2979 FAX 694-1211 SEWER & WATER MAIN EXTENS~S SEWER & WATER INSPECTION SITE PLANS ROAD DESIGN SOIL TEST Of'J S~TE WASTE WATER DISPOe~. SYSTEM DESIGN P.O. Box 196650 Ancho~g¢, AK 995~9 REFERENCE= T~c~ A; Block I; Fore6t RZdge S~bd. ZuZ6ion (Propo6ed Lot 8 ,~ 9) John SmZ,th ~a~ 6:t,t~ moth ~e On-~e S~ulc~ Oe~ ~ ~ on T~a~ A; Block 1 ~ ~e ~ proposed ~ Lot 9. A ~eq~t ~o~ ~ ~ep~c ~t~ ~ 6ub~ to Vo~ o~{Zce on ~9~e~ ~*~:~*S~ ~ ~o~-'~e 'deu~ o{.prop~6~ Lot 8;- A ~,b~u~lon p~ Z~ p¢~ng f~ approvaZ o~ D.H.H.S. mV u~6~dZng Z~ d~6cu~Z~g ~ ~ John Smith tha~ ~o,, ~ouZd ~pproua th~6e on-6~ u~z6t~ d~6po6c~ pc~t~ wo~d ~ign o~ on the Request ~o,, t~ke Zrmnedia. tc ~ctlon ,to revi~u thee de~ig~ ~nd proce~i ~ Z66u~ pe~t~ ~d p~t ~pprou~. to a~w co~ed d~ve~opmc~t o~ ih~6 p~op~V. ENCLOSURES cc ~ Taylor/COLONY BUILDERS 17034 NORTH EAGLE RIVER LOOP · SUITE 204 * EAGLE RIVER, ALASKA 99577 DRAWNJ. ANDERSON' ~ WOODHAVEN SUBDIVISION, BLOCK 1, LOT 8 I CKD. R.A.S. /~ATE 5-- 15--94 AVE. DESIGN CRITERIA: 4 BDRM = 600 GPD SOILS = 0.8 QPD/SO.FT. 600/0.8 =-,~5'0 SQ.FT. R£Q'D PROP. PRESS .~. 5' WIDE BED . ,. ~2 PROP. 19'x19' SAND FILTER DRAINFIELD: 3' DEEP (REMOVE OR/SM) INSTALL 4' LAKE OTIS GRAVEL 6' GRAVEL OVER AND UNDER DIST. PL°E 5' WIDE ~- ~ ~-OSO (~ 0 'S~' EACH) I~'o' PROP. 4 BDRM HOUSE --I I PROP. 1500 GAL. S.T.E.P. PROP. LOT 8 CONTRACTOR IS REQUIRED 1'O OBTAIN UTILITY LOCATES PRIOR TO ANY EXCAVATION WORK. MANYT£LL A V£. ALL PORTIONS OF SYSTEM I¥1TH LESS THAN 3.5' OF COVER REQUIRE INSULATION. PRESSURIZED DIST. SYSTEM: ruMP = 2o OSl 05HH 5 STATE (~~0 GPU) 3 LATERALS ~ 45' LONG EACH 10 GPM/LAT - 10 HOLES/LAT - (5' O.C.) 30 HOLES TOTAL ~ 1 GPM/HOLE 1/4' DIA. HOLES FACED DOWNWARD I-1/4~ DIA. LATERALS 2' SOLID ~,NIFOLD CLIENT \ TRACT A-1 \ LOT 9 , ,, ", £./1__ -- PROP.,.,"' "' ?."? \ \ '~ \, \ CLIENT I L[G^'FOREST RIDGE SUBDIVISION, BLOCK 1, LOT 8 l . PVC ISHT'4 OF 4 BOX ~/CORD GRIPS -FILTER CONDUIT FABRIC C01~Za OF BED THREADED CAP CLEAN OUT !3 REBAR FROM THE SEPTIC TANK 24' INSUL. LINE SAND FILTER pKRI~TF. Rk SUPPORT FRAMg; 1/2' Plywood Sheet~ lB' -- 24' DIA- DEPRZSSION DL~ CL200 i'I,USHI~G L/iVE BackRil betw,~en 2 IIIIIIIIIIIHHIIIlIIlIIIIIIIIIlI!IIIIIIlIIII {,,sul. +85 psi Burial Rated PVC CAP 1 ~ 4' P~A GRAV~ 3O ~l LEGAL FoREST RIDGE SUBDIVISION, BLOCK 1, LOT 8~ DRAWN& ANDERSON JCKD. R.A.S. JO^T~-lO-94 JSHT.3 or 4 /-30 MIL PVC LINER ;-ORIFICE SHEILD ~-- 18" '-F /0R~NCO MODEL LI/ -- 18" 18" r-'-24'--~ DIA. SCH 40 PVC LATERAL w/ .- 3~ 0 I~< DIA. oRIfice..~P~OED 4' PVC CAP -~ , o ~ ~ ~ 3Z' PUMP BASIN 15" DIA BOOTl' or (Thel-l/4'bootDIA'flangePVC-~\ · L is bonded to 30 mil \ i~H HllllHmlmHImHmHmmlHimlmllllmmllH~ mHImlH n liner) %.iuent from r~ ~' [ cf septlo tank g~' i~g~%~ ~iLl°° PV 1-1/4~ DIA. CL200 PVC-/ o I~ o ~ ~ O 0 0 4 "DIA. CI.AS$ 125 SLOTTED PVC PIPg TP, ANSPORT LINE 32.. --(clrr 1/4" ~T.l)g SLOTS e-l/2' DEEP ,' ~ AT 4" O.C.) 0 0 0 ~ 6 0 0 0 I ,%?, ' 2" INSULATION '--'/ around perimeter of filter REBAR, locate one each corner clean-out TUBE (r~P.) ~i.SLO,T"~.ED pVC PIPE. (cut ,t/4' ae SlOtS 4 O.C.-orlent SlOtS dorm to drain. TO PUMP CONTROL PANEL:Model SSF-IPTCT PVC CAP ....---TO DRAINFIELD DIA. CL,?.O0 P¥C FLUSHING LINE 2' FLUSHING V~U. VE w/8" PVC access r/sar and fiberglass cover 19' X 19' SAND FILTER W/ PUMP BASIN Propo~ Fore~ Riclge lhbdivisim: Lot S: Block 1 (Old Tr. A-l) Pa~ 1/3 IlvA~A'A'A~ SAND FIL'A~ SPECIFICATIONS Forest Ridge $~hdivlsiofl: Lo~ 8~ Blo*k 1 (Old Tr-. A-l) East 1/3 The work covered by these specifications and the plans consist of furnishing all labor, materials, tools, transportation, and equipment necessary to complete an intermittent sand filter system as described herein and on the attached drawings. All work under this project shall comply with the latest edition and addenda to all applicable cedes, ordinances and standards including MOA-DHHS septic installation guidelines and On-Site Wastewater Disposal Systems permits. 4 Bedroom single family home = 600GPD Soil acceptance rate = 20 min/in Use 0.8 GPD/SF for polished effluent 750 S.F. required Using 5' wide beds with 6" effective depth 750/5 = 150 LF Remove approximately 2' of OR/SM material and replace with Lake Otis pit run gravel. Add approximately 2.5 feet of Lake Otis gravel above original grade. Construct beds as shown. The Contractor who proposes to complete this project must carefully examine the project documents, have full knowledge thereof, have investigated the site, and be satisfied with the conditions affecting the work. Conditions include, but are not limited to those bearing upon transportation, disposal, handling and storage of materials, availability of labor, water, electric power, roads, and uncertainties of weather, physical conditions at the site including all underground utilities, the conformation and conditions of the ground, the character of equipment and facilities needed preliminary to and during prosecution of the work. The Contractor must be satisfied with the character, quality and quantity of surface and subsurface materials or obstacles to be encountered insofar as this information is reasonably ascertainable from an inspection of the site, including all prior exploratory work, as well as from information presented by the plans and specifications made a part of this project. Any failure by the Contractor to become acquainted with the available information will not relieve him/her from responsiblity for performing the work as stated in these specifications and drawings. Locations of utilities shown on the plans are not exact. Above ground utilities have been field located. Below ground utilities are shown as depicted on "as-built" plans. The Owner and his Engineer shall not be held liable for Page Two Forest Ridge Subdivision; Lot 8; Block 1 April 30, 1994 damages to utilities incurred during construction due to deficiencies or omissions on the plans. At least 24 hours prior to co~z~ncing work, the Contractor shall contact all local utility companies to obtain underground utility locates. The Contractor shall exert due care to prevent damage to utilities. Should a utility be damaged, the Contractor shall notify the utility company and shall have repaired at his own expense any damage resulting from failure of the Contractor to request an underground utility locate or to exert due care. If any utility company determines that a utility has to be temporarily raised, lowered, moved, guyed, shored, braced or otherwise protected during construction, it shall be don6 at the expense of the Contractor to the satisfaction of the utility company. Typically, there will be a minimum of eight (8) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: Inspection of work in progress maybe made by the Engineer and MOA - DHHS at any time. The following schedule of required inspections is to be adhered to. 24 hour notice is required prior to each inspection. Inspections can only be arranged during weekdays and during normal working hours. The following inspection schedule is to be strictly adhered to: 1. Septic tank/lift station is in place, but not backfilled. Sewer piping from building to tank is complete, properly bedded and backfilled. 2. Sand filter pit is excavated and prepared for filter construction. Prior to placement of filter linermaterial. Engineer to be notified with Contractor's schedule during actual construction of the sand filter to allow spot inspection during construction. Any deviation from reported schedule is to be reported to the Engineer. Final inspection of the sand filter with all pressure piping in place, but prior to placement of cover material. Flow testing of pressure piping at this time will require completion of lift station wiring prior to this inspection. Page Three Forest Ridge Subdivision; Lot 8; Block 1 April 30, 1994 5. Inspection of open trench excavation of leaching trench as per MOA code. 6. Inspection of trench with sand backfill in place. 7. Inspection of leaching trench prior to final backfill with all piping in place. Inspection will require pressure testing of leachfield piping with sand filter pump in place. 8. Inspection of final grading. The Owner shall contract with the Contractor to perform the work outlined in these specifications and plans and in accordance with the attached MOA permit. There will be no contractual arrangement existing between the Contractor and S & $ Engineering. S & S Engineering shall be the Owner's representative and will inspect the work as stated above to document the Contractor's activities. Final acceptance of the Contractor's work rests with the Owner and the MOA. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the Contractor or any other persons performing work on this project or the failure of the Contractor to carryout the work in accordance with these construction documents. S & S Engineering's inspecting Engineer will not be responsible for the construction moans, mothods, techniques, sequence, procedures or the safety precautions incident to this project. All landscaping, fences, sidewalks, paving, driveways, utility markers and other improvements, removed to facilitate the Contractor's operations shall be fully restored to their original condition and location by the Contractor unless otherwise directed by the Engineer. Items damaged by the Contractor during removal, storage, or restoration, shall be repaired or replaced in kind by the Contractor. This work shall be considered incidental to the project. Page Four Forest Ridge Subdivision; Lot 8; Block 1 April 30, 1994 ~ MA~m~IAL SPECIFICATI(~S 1. Any septic tank proposed for installation must be Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use installations in the Municipality of Anchorage: Type of Pipe Perforated Solid Cast Iron Yes Yes ASTM D3034 (P¥C) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes ASTM D2241 Yes Yes ASTM D2239-74 Yes Yes constructed by a in septic system Use of a type of pipe other than listed above must be approved by the inspecting Engineer. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). A permeable nontoxic silt barrier (Typar 3401, Mirafi 140/N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. Ail leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the ~200 sieve. When sand is being used as a filter material, its gradation specifications must conform to current MOA or DEC requirements. Page Five Forest Ridge Subdivision; Lot 8; Block 1 April 30, 1994 .~TIC TANK/LIFT STATI~ A. General The work under this section consists of the performance of all operations pertaining to furnishing and installing the septic tank/lift station and piping to the sand filter. B. Materials 1. Ta~k for Lift Septic tank shall be a 1500 gallon two compartment steel tank specifically for the use of Orenco Systems Inc. patented lift station assembly Or.nco No. 4200. The tanks shall be designed for soil loading conditions as required by Municipal and State regulations. The design or analysis shall be in accordance, with accepted engineering practice and local regulatory agencies. c. All welding shall be in accordance with applicable codes and standards. Ri~ers a. First compartment shall have a separate 4" pumpout riser. The second compartment shall have a separate four inch pumpout riser. b. An additional second compartment outlet riser shall be 12 gauge sheet steel, and shall extend 12 inches (minimum), above surface grade, shall have a minimum nominal diameter of 24 inches, and shall be capable of being equipped with the following: 1. A junction (Nema 4x) box or equal, bonded or attached to the riser. 2. UL listed electrical cord grips, installed in the J-box. c. A lid - shall be furnished with the riser. It shall be constructed of fiberglass or equivalent aggregate finish. Meet H-10 loading requirements and have a latching mechanism. Page Six Forest Ridge Subdivision; Lot 8; Block 1 April 30, 1994 d. Riser installation - each riser shall be sealed or welded to the top of the tank in such a manner as to prevent infiltration of ground water. e. Lid Insulation - four inch rigid extruded polystyrene shall be placed in the riser directly below and attached to the lid. f. Riser Insulation - two inch sprayed shop applied urethane on circumference of riser with 46465 Tnemec coating. a. Effluent pumping assembly shall be Orenco systems (TM) model 20-OSI-05-HHF series consisting of following: 1. % H.P. 110 volt or equal U.L. listed effluent pump. 2. Screened pump vault (U.S. patent No. 4439323) 59 inches deep, 3/16 inch thick high-density PVC cylinder houses the pump, level controls and screen and serves as a baffle to prevent the screen from clogging. Fifteen 1%" diameter holes are drilled in the vault at a level that places them at about the midway point in the depth of the septic. Flap check: Allows the vault to drain when removing the tank. Screen: 15 inch diameter cylinder of high-density polyethylene 1/8 inch mesh. 3. All piping shall be PVC or other non-corroding material. b. Pump controls and alarm system - Control shall be Orenco systems SICTETMRO 110 volt with following options consisting of: 1. Event counter. 2. Elapsed time mater. 3. Program timer. 4. 10 watt heater. Page Seven Forest Ridge Subdivision; Lot 8; Block 1 April 30, 1994 Se Remote alarm panel option with a minimum of 80 DB sound pressure at 24 inches, operating temperature 30AC to 65AC, continuous sound to be located in the hom~. 9. 10. 6. Oil-tight visual alarm with push-to-silence feature. audio-alarm reset. 7. Automatic 15 amp motor rated toggle switch, double pole, double-throw with three positions; manual (man), automatic (auto), and center (off) (H.O.A.). Nema 4x-rated, fiberglass, or equal, enclosure with hinged cover. All controls to be installed as per manufacturer's recommendations. Control panel to be installed on outside wall of home within sight of septic tank/lift station. c. Piping from the septic tank to the sand filter is to be 1%" P¥C schedule 40 solvent weld piping properly bedded as described in Materials Specifications and sloped to drain back to the septic tank. Insulation board 2" thick and 2' wide centered over pipe is to be placed where soil cover is less than 4' depth over pipe. In order to insure proper inspection procedure the system is to be installed in the following order: 1. Sewer line from house to tank 2. Septic tank/lift station 3. Sand filter 4. Leachfield 5. Final grading Page Eight Forest Ridge Subdivision; Lot 8; Block 1 April 30, 1994 1. Pipe Grade and Alignment: Variance of individual pipe sections from established line and grade shall not be greater than 0.02 feet, providing that such variance does not result in a level or reverse sloping invert. During the progress of the work, the Contractor shall provide instruments such as transits, or levels, for transferring grades from offset hubs or other construction guides from the control points and bench marks provided to the Contractor by the Engineer. The Contractor shall provide qualified personnel to use such instruments and who shall have the duty and responsibility for placing and maintaining such construction guides. 2. Pipe Laying: All pipe shall be laid with Class C Bedding, free of large stones and organic matter. Each section of pipe shall be handled carefully and placed accurately; the spigot end shall be fully inserted pointing in the direction of flow and glued in place to make a watertight seal. Each section of pipe shall be properly supported to insure true alignment and an invert which is smooth and free from roughness or irregularity. At all times, when work is not in progress, open ends of pipe and fittings shall be securely and satisfactorily closed so that no undesirable substance will enter the end of the pipe or fittings. 3. Bedding of Pipe for Sewer Lines: The pipe should be bedded with Class C Bedding materials compacted to 95 percent. Native materials may be used as backfill material above the pipe, provided it is free of large stones and organic matter to a point one foot above the top of the pipe. Installation. All pumping services shall be installed in accordance with the manufacturer's recommendations and standards. Electrical installation is to be to code by licensed electrical contractor, with Municipal inspection where required. If MOA inspection not required, a licensed electrician is to provide letter to the Engineer stating that the system meets or exceeds all applicable Cedes. Page Nine Forest Ridge Subdivision; Lot 8; Block 1 April 30, 1994 4. Exca~atim: be Excavate to proper depth to allow gravity flow, install tank level, tolerance 0.O1 foot, on undisturbed or compacted to 95 percent classified sand fill material. Line excavated tank pit walls with two inches +35 PSI burial foam full depth of tank. Backfill between tank and foam with sand material and compact, in a manner to prevent damage to tank surface coating. Create a level sand surface over tank and add two inches burial foam +35 PSI directly over tank. Mound unclassified soil over tank location to a depth of two feet above finished grade to allow positive drainage away from tank and counteract buoyancy. a. Ail connections to be as per MOA - DHHS and UPS requirements PVC 3034 piping with Caulder or equivalent couplings for inlet riser pipes. b. Ail tank connections are to be completely water tight. SAND FIL'&~ The work under this Section consists of the performance of all operations pertaining to furnishing and installing the sand filter. A. Materia/s 1. Sand Filter: a. The contractor shall provide a washed sand to meet ASTM C-33 Concrete Sand specifications with the additional requirement that all but 1 percent of the materials passing the t100 sieve be removed. A sample of the proposed filter sand must be submitted to the Engineer for testing one week prior to construction. A sample will be taken from the sand bed during construction for purposes of quality control. If the sample does not meet specifications, all sand will be removed and replaced. Page Ten Forest Ridge Subdivision: Lot 8; Block 1 April 30, 1994 Contractor shall be responsible for providing pea gravel. Where pea gravel is specified, the pea gravel shall be a washed material containing no fines (0 percent passing the %100 sieve) and a maximum size of %" diameter. Contractor shall be responsible for providing round rock. Where round rock is specified, the round rock is to be washed gravel with rounded edges well graded with maximumdiameter of %". Contractor shall be responsible for providing the manifold assembly. Manifold assembly shall be the Orenco Model SFM 1036 Or equivalent with orifice shields and flushing assembly. Ail drilled holes to be cleaned of burrs and pipes flushed prior to assembly. Flushing valve to include riser to +12 inches above finish grade with extension handle provided to operate globe valve from ground surface. Liner - Or.nco Model LI Or equivalent. 30 mil PVC cut and fabricated to provide water tight enclosure of filter sand volume. Seams to be permanent as per Manufacturer's recommendations. All connections, such as boot flanges, through sand filter to be permanently bonded to liner. Pump Basin - Sand filter pump basin is to be Orenco Model PBSF1561FI with flow inducer and matching 15 inch diameter riser sections as needed to extend 12 inches above finish grade maintaining a water tight seal through the full length of conduit riser. PVC splice box to be installed with a conduit seal kit. Filter Secondary Pump - Orenco Model 20 OSI 05 BHF with appropriate float assembly and high pressure discharge assembly. Contractor shall be responsible for providing filter fabric, filter fabric shall be Orenco Model LIFF or equivalent. Contractor shall be responsible for providing insulation. Insulation shall be +35 psi board rated for direct burial. The 2 inch thick rigid insulation on the sidewalls of the filter box shall extend the full 4 foot height of the plywood box and be inside the plywood box. 2. Construction of Sand Filter: Sand filter construction is to follow procedures as outlined in the Orenco Installation Manual as applicable to this design. Care is to be taken to protect the integrity of the sand filter PVC liner material. This includes Page Eleven Forest Ridge Subdivision; Lot 8; Block 1 April 30, 1994 careful placement of soil material into liner. Any perforation of the PVC liner material will require patching in a method that exceeds original manufacturer's strength. Rock, pea gravel, and filter sand are to be hand leveled to proper depth (tolerance within 0.01 feet) in filter, taking care not to allow mud or fine soil material into the filter or rock layers. This would include mud or fine soil material into the filter or rock layers. This would include any soil material picked up by excavation machinery buckets while loading specified material. Contractor should estimate filter materals volumes such that allowance is made for wastage of material in contact with ground at site. Work .on the sand filter may be suspended at Engineer's discretion due to inclement weather conditions such as rainfall. The sand filter and material stockpiles will be completely covered by a tarp overnight during construction until finished. Filter internal construction should be accomplished in one day's time. The Engineer will reject any sand, round rock or pea gravel that does not meet specifications or is contaminated in transit or while handling. If such material is placed in the filter, all soil material may be required to be removed and replaced with new material. 1. General The work in this section pertains to furnishing all materials and installation of the septic leachfield. 2. Materia/s All materials shall be as approved by the MOA - DHHS for leachfield construction. Leachfield piping is to be fabricated to allow pressure distribution. Ail holes in fabricated piping are to be deburred and flushed clean. 3. Cormtructi~ Construction is to be as per MOA - DHHS Code and guidelines. Page Twelve Forest Ridge Subdivision; Lot 8; Block 1 April 30, 1994 4. mminfield a. The drainfield is to be located in position shown on site plan. b. The bottom of each drainfield excavation shall be level, plus or minus 1.5" or 0.13'. c. Leachfield trench is to be excavated to indicated depth and backfilled with Lake Otis gravel material to sewer gravel level. d. The lb" effluent pipe is to be level in leachfield. e. The drainfield gravel is to be cc~pletely covered with typar fabric material. fe The area over the drainfield and sand filter is to be finish graded to prevent ponding of surface water runoff over and between trenches. Topsoil 6" and seed. 5. Leachfield Dimensions: TOTAL DEPTH = 2.5' above orig. grade DRAINFIELD LENGTH = 150' SOIL RATING = 0.4 GPD/sq.ft. POLISHED EFFLUENT = 0.8 GPD/SF GRAVEL DEPTH = 1' DRAINFIELD WIDTH = 5' BEDROOM CAPACITY -- 4 Municipality of Anchorage . DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street. Anchorage, Alaska 99502-0650 SOILS LOG .-- PERCOLATION TEST LEGAL DESCRIPTION: ~ ~ I~ ~ Township, Range. Section: SLOPE SITE PLAN 1 2 3 4 5 6 7 8- 9- 10- 13- 14- 15- 16. WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT- DEPTH? Depth to Wator ~er :N Reading Date Gross Net Time Time Depth to Net Water Drop 17 18 19 20 COMMENTS PERCOLATION RATE .~ TEST EETWEEN .- (mmuteshnch) PERC HOLE DIAMETER - FT AND ./"~'-'~ FT PERFORMED BY: $ & S ENGINEERING I '"'~--~r~ CERTIFY THAT THIS TEST WAS PERFORMED IN 17034 Eagle River Lo.o~p.,Ro..a.d No. 204 ~ ACCORDANC£ WITH Ll~;l~li~Tr~l~,,~jklj~;'~".r,~,~,r~.,.~UlDELiNES IN EFFECT ON THIS DATE. DATE: '~' -- I '~ __.C~ ~ 72-008 (Re~. 4/85~ Municipality of Anchorage .-. DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG .-- PERCOLATION TEST PSRFORMEOFOR= -- OATEPERFORMED: ~b~-~ L~'r.~' ~c~ ! 8 10 WAS GROUND WATER r~J ENCOUNTERED? 11 [P ','ES. AT W,AT" __ 12 ~,O,H. DEPTH? 14 18- 19- 20- COMMENTS Township, Range, Section: 0epth lo Waler ~er Moflitorin0? D~lt SLOPE SITE PLAN PERCOLATION RATE . J'~*~* (m,nuteu,nch) PERC HOLE DIAMETER TEST RUN BETWEEN '~ FT AND dC~ ET PERFORMED BY; $ & S £~k:O iNEqRING ~ ~ ~ CERTIFY THAT THIS TEST WAS PERFORMED IN 17034 E River Leo Read N .~ MUNICIPALITY OF ANCHORAGE BEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-.4744 CiFALI1'/OF ANCHO~AGE NME,',~AL Sc~RVICES DJ'IlS:ON SEP 08 1937 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. # OI '/--ll3-- ~7 .:..:HAA# GENERAL INFORMATION · Complete legal description RECEIVED Location (site address or directions) ,..~ Pro.perry owner'.. ~ o re c~, c Day phone ;..:, .ailin. g address "~'.~ ¥o ..... ..Lending agency · %";Mailing address' -' '-'~.ent ' '" Address Day phone Day phone 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Unless otherwise requested, HAA will be held for pickup. NOTE: Individual well X Community well Public water If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. · TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage fil~s and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulat!ons in effect on the date of this inspection. $ & $ ENGINEERING Name of Firm 17G~.4 r--.,t~|,. ~; .,~, L~.~p F,,~.~ ;,,;~. iG,; Phone Address Eagle RIYer, Alaska 995~7"/ Engineer's signature '~~-/"Z/"--,~ Date Se DHHS SIGNATURE Approved for Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Additional Comments Date c~_ ¢_~ ,7 The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given In paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Municipality of Anchorage ~UNICIPALITY OF DEPARTMENT OF HEALTH & HUMAN SERVI(7,E~O~4ENT^L Environmental Services Division 825 L Street, Room 502 · Anchorage, Alaska 99501 ° (907) 34~F..~(J~ 1997 Health Authority Approval Checklist RECEIVED Legal Description: L~.r &: ~.c~c I; ~-m~- ~tp~e -~percol I.D.:. Or'/ -II'~ .- 0-7 A. WELL DATA Well type Log present Total depth Sanitary seal If A, B, or C, attach ADEC letter. ADEC water system number Date completed '/ / / '//'t 7 Cased to ~ ¥ q ~ Casing height (above ground) Wires properly protected~/N) ¥ '~ £ Date of test Static water level Well production ' WATER SAMPLE RESULTS: FROM WELL LOG AT INSPECTION //7/q 7 / ~- 0 g.p.m. / ' g.p.m. Coliform Nitmte O. Io o Other bacteda 0 Date of Sample: B. SEPTIC/HOLDING TANK DATA Date installed Tank size Foundation c!eanout.(l~)) Date o~ Pumping > ABSORPTION' "~' FIELD DATA Date.imq~lled ~ - ~. - °1 '7 Effectiv~ absorption area ":/~o Deprassion (Y~) Pumper Collected by: S & S EN§II~"ERING 17034 Eagle River Leap Read Ne. 204 Eagle River, AIm~km 99577 I~oo Number of Compartmants ~_ Cleanoute(~]N) ¥6'5' Date of adequacy test So, rating (g.p.d./fFoK~) Fluid depth in absorption field before mst (in.); Fluid depth ~ (ins) Minutes later: High water alarm System type Peroxide treatment (past 12 months) (Y/N) Gravel thickness below pipe O. ~ t Total depth ' . ~' Monitoring Tube present (~N) Yes Depression over field (Y/l~) ~J o Results (Pass/Fail) -- For Lf .bedrooms Immediately after "~gaL water added (in.): '----" Absorption rate = g.p.d. If yes, give date 72-026 (Rev. 3/96)* D. LIFT STATION Date installed ~, -' ~ G -¢~'[ Size in gallons Manhole/Access g/N) ~f '~' -,~ 'Pump on" level at* High water alarm level .at* N ~" · *Datum Cycles tested 'Pump off" level at* 3 ~) E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: SepficAlolding tank on lot I ~o1'4' Absorption field on lot I o Public sewer main t~ /~- Sewer/septic service line 2 ~ I"t On adjacent lots I oo'-t* On adjacent lots Ioo~-t Public sewer manhole/de;moot Lift station I oo Iff. SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Foundation ~ i '1' Pmpe.rty line e,o' .'r Absorption field. I o t-f Water maln/ssrvice line I o '.4. Surface water/drainage I o o I + Wells on adjacent lots SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOTTO: Property line I"t Building foundation I o I .I- Water maln/ssrvice line Surface water ! od ~- Driveway, parking/vehicle storage area Curtain drain ~Or~: ~.~t ~d Wells on adjacent lots I F. ENGINEER'S CERTIFICATION ,. I cerUfy that l have detennined lhru fleld inspecUons ond review of Municfpal mco~~~~A s are in conforflmn¢~ ~ MOA HAA guidelines in effect on this date. Date / ? Date of Payment ~~'- 72-026 (Rev. 3/96)* Waiver Foe $ Date of Payment, Receipt Number