HomeMy WebLinkAboutFOREST RIDGE BLK 2 LT 4 Municipality of Anchorage Page DEPARTMENT OF HEALTH AND HUMAN SERVICES · . ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Dispos.al System and/or Well Inspection Report Permit Number: -~WcjqOIN7 'PID Number: QI7/Izc/'5'' Name: ~ Wastewater System: ~ New [] Upgrade Address: ABSORPTION FIELD Phc=~ ~ No, of B~drooms: ~ Deep Trench D Shallow Trench ~ Bed ~ Mound ~ Other LEGAL DESCRIPTION so, Rating: Total Depth fro~ original grade: Lot: Block: Subdiv~ion: Depth to pipe ~ffom from original grade: Gravel depth beneath pipe Township: I Range: ~ion: Fill added sbove original grade: ~ Gravel length: I WELL: ~ New D Upgrade ~ravel width: /~ Ft. Numbe[ of lines:~ Dis~n~ ~be~n'~lines: Classification (Private, A,B,C): Total Depth: Cased To: Total absorption area: Pipe material: ' ~ / Casing HeightAboveGround: SEPARATION DISTANCES ~ septic ~ Holding / TO Septic Absorptio~ Lift Holding ~ubli~Private M~nufacturer: Capaci~n gallons: Su~ace ,~ ,~ ' LIFT STA~ Lot Size in gallons: ~ Manufacturer: "Pump on" level at: "Pump off" level at: ~ High water alarm at: Remarks: BENCH MARK Location and D~cription: Assumed Elevation: ENGINEER'S SEAL Reviewed and approved by: , . _ Date: ~- ~ ~- ~¢ 72-013 (Rev, 9/91) MOA 25 Permit No. SW940147 Page 2_ of 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal DescriptioFnO:REST RIDGE SUBDIVISION, BLOCK 2, LOT 4 PID No.: 01711295 CO1 C02 GAL i A B FC0 2.5 C0~ 46.0 20.0 C02 53.0 28,5 M.~. 54.5 30.0 MTB 23.5 44.0 MTB 99.5 79.5 MT4 96.5 75.0 30.0' i MT1 GRADE Z"' ~NSUIAT~0N'" ~ 94.8' I02.4z TOPSOIL ~ SEED 105i8' MT2 ;RADE 102.9'- ~ i 4 BDRM ~ LOT 4 iI 1250 GAL ~2 ~ S.T.E.P. sc~ NEW PRES DISTRIBUTIO 1" =40' BED MUNICIPALITY OF ANCHOP~AGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 PAGE 1 OF ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW940147 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:WARE DANIEL L & KAREN P OWNER ADDRESS:9806 RELIANCE DRIVE ANCHORAGE, AK 99507 DATE ISSUED: 5/27/94 EXPIRATION DATE: 5/27/95 PARCEL ID:01711295 LEGAL DESCRIPTION: FOREST RIDGE BLK 2 LT 4 LOT SIZE: 53104 (SQ. FT.) NLrMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 (24 HOD-RS) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: THIS SYSTEM MUST BE INSTALLED AS SHOWN ON THE REVISED AND APPROVED DESIGN DATED 4/29/94. THE POINT OF ENTRY INTO THE BED FROM THE LIFT STATION MUST BE AT THE MIDPOINT OF THE ? DATE: DATE: 1LEGAL FOREST RIDGE SUBDIVISION, BLOCK 2, LOT 4 I DRAWN J. ANDE:R$ON ICKD. R.A.S. I DA'E4--9--94 ISHT- 1 OF 2 DESIGN CRITERIA: STRUCTURrS. EASEUENTS. OR ENCROACH,ENTS SHOWN ON THIS SITE PLAN ARE AS SHOWN ON 4 BDRM. = 600 GPD AN AS-BUILT SURVEY DRAWN BY: SOILS = 0.5 GPD/SQ. FT. JEFFERY A. GASTALDI 600/0.5 = 1200 SQ. FT. REQ'D IT IS THE RESPONSIBILTIY OF THE CONTRACTOR TO VERIFY EASEMENTS, REQUIRED SEPARATION SOUTH DISTANCES. AND PROPERTY LINES PRIOR TO qDSOR CIR. CONSTRUCTION. RADIUS CRITERIA 1.5' DEEP 6" GRAVEL OVER DISTRIBUTION PIPI 2" INSULATION REO'D 2' MIN. COVER 12' WIDE , c,~' 100' LONO ~'xYLOT'5 TO CUT~ANK LOT 5 WEt.L PROPOSED 4 BDRM HOUSE LOT 4 PROPOSED 500GA~. $.?.E.P. · or ~'~D I tO' UTIL £SMT RECEIVED MAY 2. 1994 Municipality ol Anchorage Dept. Health & Human Services CONTRACTOR IS REQUIRED TO OBTAIN UTILITY LOCATES PRIOR TO ANY EXCAVATION \ ~ORK. LOT 1 4 PLATTED ~ELL GREENPOINT_ __ AVE_. ~ _ __ CLIENT ILEGAL DRAWN FOREST RIDG]~ SUBDIVISION. RT,OCK P. I,f)T d L. S. ULSHER IcED. R.A.S. IDATE 4/29/94 I SHT'2 OF' 2 PRESSURIZED DISTRIBUTION SYSTEM: PUMP = 20 OSl 05HH - 5 STAGE (~30 GPM) 4 LATERALS ~ 47' LONG EA. = 7.5 GPM/LAT 12 HOLES/LAT (4.25' O.C.) - 48 HOLES TOTAL ~ 3/i6" DIA. HOLES FACED DOWNWARD 1 1/4" DIA. LATERALS .6 GPM/HOLE 1" DIA. SOLID MANIFOLD ~ 0 DETAIL r ~' TOP$OF.. & SEED 2" INS'OL~TION II / II / {.5' Dm, m~ovE o~cs)J l~l I . DIST. P S ~ wrr~IN' SE~ER ROCK. 6' UNDER & 2" OVER DIST. PIPES PROFILE RECEIVED MAY 2 1994 Municipality of Anchorage Dept. Health & Human Sen/iDes ROBERT SHAFER. P.E. ROGER SHAFER. P.E. April l~ 1994 CIVIL ENGINEERS (907) 694-2979 FAX 694-1211 SEWER & WATER ie~SPECTION SITE PLANS ROAD DESIGN Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES 825 'L' Street P.O. Box 196650 Anchorage, Alaska 99519-6650 REFERENCE: Forest Ridge Subdivision, Block 2, Lot 4 Request you Issue a permit to drill a well and install a septic system to serve the proposed four bedroom house on the referenced property. Test holes were excavated and percolation tests performed. The approximate location of the test holes are located on the attached site plan. At the time of excavation water was encountered at 8 feet in test hole one and after seven day water monitoring water was found at 8 feet in test hole one. This property has enough area fora future septic upgrade which can be seen on the attached site plan. We do not anticipate any adverse effects on neighboring oroperties by the installation of the proposed septic system. ff you have any questions, or require additional information for your review, olease contact us. ~s'~c°~~rt A. Shafer, P.E. / ~RAS/LSU/Isu ONSITE WASTE WATER DISPOSAL SYSTEM DESIGN 17034 NORTH EAGLE RIVER LOOP * SUITE 204 · EAGLE RIVER, ALASKA 99577 I LEGA{'FOREST RIDGE I DRAWNJ. ANDERSON TRENCH: 5.5' Dr£P 3.5' EFFECTIVE 2" INSULATION REO'D 5' WIDE 81' TOTAL LENGTH SUBDIVISION, BLOCK 2, LOT 4 I CKD- R.A.S. I DATE4--9--94 I SHT' 1 OF 1 DESIGN CRITERIA: 4 BDRM. = 600 GPD SOILS = 0.8 GPD/SQ. FT. 600/0.8 = 750 SO. FT. REO'D SOUTH )SOR CIR. RADIUS ~ LOT $ STRUCTURES. EASEMENTS, OR ENCROACHMENTS SHOWN ON THIS SITE PLAN ARE AS SHOWN ON AN AS-BUILT SURVEY DRAWN BY: JEFFREY A. GASTALDi IT IS THE RESPONSIBILTIY OF THE CONTRACTOR TO VERIFY EASEMENTS, REQUIRED SEPARATION DISTANCES, AND PROPERTY LINES PRIOR TO CONSTRUCTION. LOT 5 PROPOSED .OUSE LOT"~t PRESSURIZED· DIST. SYSTEM: PUMP = 20 OSI 05HH - 5 STAGE (~30 CPM) LATERALS ,,, $8.5' LONG EA. = 15 OPM/LAT. 15 HOLES/LAT (2.75' O.C.) - 50 HOLES TOTAL =~1 GPM/HOLE DIA. HOLES FACED DOWNWARD LATERALS x, % CONTRACTOR IS REOUIRED TO ~ I ~ OBTAIN UTILITY LOCATES \ PRIOR TO ANY EXCAVATION x, .WORK. 70 CUT~NK CO S.T.E.P. PRESSURE SYSTEM TO FOLLOW OF LA.ND 10' UTIL ESMT LOT 14 GREE_NPOINT_ AV.r._ CLIENT ON-SITE WASTEWA TER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPEClFICATIONS REFERENCE: Forest Ridge Subdivision, Block 2, Lot 4 GENERAL: 1. The scope of this project includes the installation of a 1500 gallon septic tank effluent pumping (S.T.E.P.) system and a pressurized five foot wide drainfield to serve the proposed four bedroom residence for the referenced property. Construction shall be in accordance with the approved site plan and design drawings; Municipal permit with any special provisions or conditions; and all applicable State and Municipal Wastewater Disposal Regulations. The contractor shall be responsible for obtaining any necessary underground utility locates. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. On all leachfield mound systems, the property owner shall be responsible for ensudng a satisfactory vegetation growth over the mounded area. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. SEPTIC TANK INSTALLATION: A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4' cleanouts for pumping access. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. Page Two Forest Ridge Subdivision, Block 2, Lot 4 April 10, 1994 4. Septic tanks installed with less than 4 ft. of cover shall be insulated. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfie/d there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (ruffed-up) before gravel (sewer rock) placement. Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. A silt barrier must be installed between the finalgravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. Monitor tubes shall be of four (4) inch diameter and installed approximately in the locations shown on the design. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. Page Three Forest Ridge Subdivision, Block 2, Lot 4 April 10, 1994 MINIMUM MATERIAL SPECIFICATIONS: Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. All leachfield gravel (sewer rock) shall be 0.5'-2.5" screened gravel with less than 3% passing the #200 sieve. When sand is being used as a filter material, it's gradation specifications must conform to current M.O.A. or D.E.C. requirements. Page Four Forest Ridge Subdivision, Block 2, Lot 4 April 10, 1994 INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. The second inspection must be conducted after the placement of the silt barder, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. 3. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR/CUSTOMER PERFORMED FOR: LEGAL DESCRIPTION: LI~ t_ i~-- ,. 1 2 :3- 7- 10 14 16- 72-008 (Rev. 4/85) I . ~,(ENGINI~ER.'S SEAL) 825 '~' Street. ~ ~ ~anoe, Section: WAS GROUND WATER ~,A~'O,~ ENCOUNTER ED? /v IF YES, AT WHAT ~ O DEPTH? p E 4 DiI~ SLOPE SITE PLAN Reading Date Gross Net Depth to Net Time Time Water Drop 12: ~ ~ ~ ~" -- :~ I0~,~ ~" I" ~ ~6 (o ', ~ ~" 1:o6 (~ ,. ~e" ~y ; : /~ I~ - ~ ~e" ~y,' 20- PERCOLATION RATE . TEST RUN BETWEEN COMMENTS S & S ENGINEERING / 17034 E~gle Riv~ Loop Road No. 204 //~ PERFORMED BY: E.~;. R;,~,, A;..;,. ~r;3~* ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELI~)~tlq EFF. I I~::)'~ (m,nutes/,nch) PERC HOLE DIAMETER /~'~T AND ~"~ FI CERTIFY THAT THIS TEST WAS PERFORMED IN T ON THIS DATE. DATE: (ENGINEER'S SF-.~L) Municipality o! Anchorage "~'~:"~/ '"~'~'~ °. "2 · DEPARTmEnT OF HEALTH & HU~ SERVICES SOILS LOG -- PERCO~TION TEST LEGAL OESCR,PTION: L~ ~ ~: ~T ~,D*E Townsh'p, g, Section: SLOPE SITE PLAN 1 4- 5- 6- 7 9 WAS GROUND WATER 10 ENCOUNTERED? I~ IF YES, AT WHAT DEPTH? 12 13. ~i~? Reading Date Time Time Water Drop 14- 15- 16- 17- 18' 19- 20- PERCOLATION RATE ('"~'~ Immutes~mch) PERC HOLE DIAMETER TEST RUN RETWEEN .~.~,~T AND ~ FT ACCORDANC~LL ~TE AND MUNICIPAL GUIDELI~ECT ON THIS DATE, DATE: 72~ (Rev. 4/~) ~ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P,O, Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D. # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING 0 I'1 '-113, _6~,.~' HAA# ~-~{~c~l~ ['~L'~ · ,'~ 1. GENERAL INFORMATION Complete legal description Lot 4: Block 2; Forest Ridge Subdivision Location (site address or directions) Property owner Mailing address 15141S. Windsor Circle Anchorage, AK Ron Kincannon Day phone 345-7924 630 Clippership Court Anchorage, AK 99515 Lending agency Mailing address Agent Address ' Premier Mortqaqe Day phone 563-7736 Day phone Unless otherwise requested, HAA will be. held for pickup. NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual well Community well Public water 4 ',4 NOTE: If community ~el! system, provide written confirmation from State ADEC attest- lng to the legality and status of system. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. Be STATEMENT OF INSPECTION BY ENGINEER. As certified b~' my seal affixed hereto and as of the validation date sho~n below, I'verify that r~y ' investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspect[on, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations In effect on the date of this inspection. Name of Firm s & s ENGINEERING 17034 Eagle River Loep Roed No. 204 Engineer's signature. ~p~.~/~,, ~,~ Phone Date DHHS SIGNATURE Approved for Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Additional Comments The Municipality of Anchorage Department of Health and Human Servi'ces (DHH$) Issues Health Authority Approval Certificates based only upon the representations given In paragraph 5 above by an independent professional engineer registered In the State of Alaska. Th~ DHH$ does this as a courtesy to purchasers of homes and their lending Institutions in orderto satisfy certain federal end state requirements. Employees of DHH$ do not conduct Inspections or analyze data before e certificate Is Issued. The Municipality of Anchorage Is not responsible for errors or omlsalons In the profeesional engineer's work. ~NICIPAiJTy OF ANCHO~--~ Municipality of Anchorage ~~ ~2 ~ DEPA~ENT OF H~L~ & HUMAN SE~ICES OCT 09 ]99~ En~mnme~l Se~s Dillon 825 L Street, R~m 502. ~chomg., Nas~ 99501. (90~ ~lVE -~ -- Health Authority Approval Checklist LogalDescripfion:.£o7- # /~c0c~ 3. F~,~$r /f,a¢;~ ParcalI.D.: OI -/ -If ~ - '7 .f- A. WELL DATA Well type Log present~/N) Total depth Data completad Sanitary ssal (~) Y~ · If A, B, or C, attach ADEC letter. ADEC water system number Cassdto ]11 Casing height (above ground) I -./- Wires property protected (~N) ¥ ~ $ Date of test FROM WELL LOG AT INSPECTION /o/;~ Static water level Well production WATER SAMPLE RESULTS: O Coliform Data of sample: I o / ~. / 8.~'~'~OLDING TANK DATA Nitrate g.p.m. 0.1 Collected by: Other becteda O S & S ENGINEERING ;TG;-; ;..;. R;v,r Loop koaa ~o. zo4 Oatalnstalled ~/q/q?/ Tanksize /~''c~*'Y' Number of Compartmenta Founclaflon cleanout C~/N) ¥~5' Depmsalon (Y4~j ~. , .' . Data ~Pumpin. g '1o /~- Pumper /~ C. ABSORPTION FIELD DATA - Date ir, stalled (; / q /~1~" Soil ratfog ~er ftaAxlrm) Length. / o o .Wldt~ ' ~ ~ Effecfive al:mo~fion ama / ~' ~ ~ Dateofa~equacytast ~o / ~/'~(, Grovel thickness below pipe O. 3- ' Total depth 3. ~" Monitoring Tube present (Y/N)~ Depression over field (Y/N) ~ Results (Pass/Fall) ~P/4 $ .( For ~// Fluid depth in absorption field before test (In.); P'<' t( Immediately after ~ q ~/gal. Water add~cl (in.): Fluid depth O (ina) Minutes later: ~- ~l (3 Absorption rate = (: o ~ -/- g.p.d. Pemxtdetmatment(past12months)(Y/N) ~,,~/L ~:/-'G~,,../ Ifyes, givedata ~' .bedrooms ) 72.026 (Rev. D. LIFT STATION Date installed ~ / ~ / ~/¥ Size in gallons Manhole/Access (~N) Yf- J' 'Pump on' level at* (; q" High water alarm level at* (o 5' *Datum 7o,~ ~; Cycles tested 3 /3'00 "Pump off" level at* E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: T~6~'~olding tank on lot ! o o ~ ~ Absorption field on lot Public sewer main Sewer/septic service line On adjacent lots On adjacent lots Public sewer manhole/cleanout Eft station SEPARATION DISTANCES FRO~OLDING TANK ON LOTTO: Foundation ~ o Property line ~ '~- Absorption field Water maln/sorvice line 6'"~ '+ ~ ,Surface water/drainage ! o o * Wells on adjacent lots SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line I o ~ Building foundation ~ o Sun'ace water ) ~ o ' Y- CurtaJndraln ~ve~,e ~<,~ ~' Water maln/ssrvice line Driveway, parldng/vehicle storage area Wells on adjacent lots / R ENGINEER'S CERTIFICATION are Signature ~/~'~5~// '":-/---,YT..~ " Receipt Number '/~3,~' 724326 (Rev. 3/96)* Waiver Fee $ Date of Payment Receipt Number OCT-(~J-I~O~6 (~'7:44 P.01 KLL 2540 LQI~ CI1~1 LOT 14 JL[ 12 grd Dt.t Inv. Dr: CUSTOItER P.O. · ~IP VIA TERIIS git NET ~0 KQ'D DATE O~D~R ! 00544t ORO'~ ~[P !10 ITT# Ill ! t O ImEAS1~4 ! ! 0 Ira4! I I O ImOSILIDS ~ ! 0 OStler I I 0 0S[4004 LIK Till[ SYST~ IS~Q GN. 8J~E LIFT RISER SADIST, 24' LI~ RZ~ 4' LI~ RI~ LTl, E I~A LIFT P~sUFL~T~I,tl2 ~ LI~T PU~ PLT OSI 400Q 15~025.0Q t3,025,0¢ ~ost-lt' b~nd fax transmit~J memo 7671 Thy TQ%eTs Totd] Duel $$,02~,00",~. TOTRL P.01 18/18/1996 18:14 907694121! S A~ S E]qGIN:~_~ING STAt ,z ALASKA D~ARTMQ~IT O~"NATURAL RE~OURCE~ DIVISION OF' WATER ~VAT[R ~LL flsr~ORO LOCATION OF WELL .,.. .. . ..., · Mata~t,Type a~ ~fo( ~m To Os Ow oe,,m of ho:e: //-~ Depth of caslng:~/~4/ ft PAGE 02 P.01 7': I'1 ground eu~faom R FCE JVEg.l.:li:.!, il oCT 10 199~.:i~ '"I~I Municipality el Anch.c~.age-'-~:. j Dept. Health & Human 8.ervl¢?~.". j GROUT TYPE: Volume: Oept~ from' it to _ _it PUMP~G L~CL ~O YIELD: PUMP ~AKE DEPTH: It Horaepowen ~D~NF~O UPON COMP~ION? ~ ~ HO CONTRACTOR INFOR.'~,~TION: .. '. ' ;.. R~,tAF~S: . · ~gist~t~O ~uslness Na~e '~ ~ .," ' ~ , DNR~ISION OF WAIER ~,g~t~e el Aut~Nzed Resprgs~ta~ve DaCe... ~CLE PO BOX 772116 RIV[R AK 99577-2116 · .,. '" ":'-·'CERTIFICATE OF HEALTH AUTHORITY : ' ... APPROVAL FOR A $1NGLE FAMILY DWELLING - :~ ::'" :'""'" Location (site address or directions) · ,~. ,' Day phone Property owner - ~ailing address ..... '" ' ; Day phone . . .... · .. ... , .- j..~,.,,..........,,. . :.:..~.. :.,:~,:~.~,. · ,.. . · ,., ..- · NUMBER OF BEDROOMS: 4 · ' '" ..... 3. TYPE OF WATER SUPPLY: · " v en confirmation from State0 : DEPARTMENT OF HEALTH&HUMAN sER~/ICES: ':,' i~J~i~ "~?":'~. .~,.:. Division of Environmental Services :-;:~..I.l~::li~ :'~."' ":'~'-~!'?;"" . , ~.., ~....:,,~,.;.On-Si~Servlc.es,.sectlo.n.:,,'_:;:~,~.':'3~.~5.~, - ,~ .' ... ;:,.. :~*;.-.:?;-343-4744,:~:'::.?~'~.~ ~ .~.~:;:~.?:.:. ~.: :,~,,: ... 5. STATEMENT OF INSPECTION BY ENGINEER ' ' "',:': "-"' .* ' · ; [ As certified by my seal affixed hereto and as of the validation date shown below, I verify that mv ' .. Inv~tlgaUon of th~s Health ~uthonty Approval application show~ that the on-~ite water su~o ~"::: :.:~; al;Id/or wastewater di~posal syStem.is safe, functlo, nal and adequate for the number of .bedro?.,m.~ ~i 'i~ and tYpe ~f structure Indicated here,ri. I further ~enfy that I~a~e~ on'tl~ info r~11~1~"~ btm ned f~3~q'~. .' !~::" · the Munic~pahty of Anchorage files and from my Investigation and Inspection, the on-~tte W~/t~ ~}- ' ~ supply and/or wastewater disposal system Is in compliance with all Municipal and State codes, ;' ordinances, an~ regulations in effect on the date of this insp~ion.' - ' ' '~. ................ · : -?'-~ :~ :?. .. Name of Firm · : $&s ENGINI~ING Phone G~i'Y- 2~ ~/7' ¢' =.;" :' '.~',.. <..: ,, .,:.. ,,'~]4rr..~ltt.~rt,e~p..~l~ , , ....... · '.".;'Address.___ ' Rl~-~'/J~drc¢~,~77 .~',--*, .,. ,,.t ....~ .......: ': Engineer's signature R : Municipality of Anchorage Department of Health and Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: L A, Wall Data Well type Log presenl~N) t'('t~"~..~ Total depth / I.~' · Sanitary sea,N)~"~, (~ Date of test Static water level Well flow Pump level1 ~ ~-- /C'o/~EST" Parcel I.D. If A, B, or C, attach ADEC letter. ADEC water system number Date completed ~r'/?/~''~ Drillei'/Z~O/~u~' L~_K.L./~.~J~. ~ Cased to '1 ~ I ~' Casing height ~res property protected) AT INSPECTION / - SEPARATION DISTANCES FROM WELL TO: Septic , - nk on Absorption field on lot Public sewer main ~'~,.(' Sewer service line ; On adjacent lots ; On adjacent lots Public sewer manhole/cleanout Petroleum tank WATER SAMPLE RESULTS: Coliform ~)/('~ , Nitrate Date of sample: '7_~/~,./~4- / O, fO "~/,~, Other bacteria Collected by: ,~"~ .~' B. SEPTIC~.,'CLC',:;C TANK DATA Date installed ~_p[c//,~/_.~ Tank size Cleanouts~)'-'F~''~' Foundation cleanou~) High w;ter alarm~N) SEPARATION DISTANCES FROM SEPTIC/I'I~:O~N~TANK TO: - Well(~s) on lot ~/(~Y,..~/"/-'" On adjacent lots To property line ~O (-~ Absorption field Sudace water/drainage /00 ~ (~/~ c.. Compartments ~.- .C~ ~'C/ Depression (v~ Alarm teste~N) ~"r~'~' Pumper Foundation ~..O t Water main/service line /(~/'/'- CONTINUED ON BACK PAGE C. UFT STATION Date installed ~'/~' / ~'~" Size In gallons Vent ~N) y_~ 'Pump on' level at High water ala~ level Meets MOA el~l c~es~) SEPA~TION DISTANCE FROM LI~ STATION TO: Well on lot ~ ~ On adjacent Io~ Manufacturer Uanhole/Access(~)N) z~.. '~ '~ 'Pump off" Level at Cycles tested *~'(:~-~ '~' Sudacewater /o0/'-~' D. ABSORPTION FIELD DATA Date installed Length /~00' ' Total absorption area Date of adequacy test Water level i~ absorption field before test Peroxide treatment (Past 12 months) (Y~ 4; / +- so, ,ating (GPD/Ft ) Width /-~/ Grovel thickness /-~*O0 ~ Cleanout present(~l) /~//,J~ '/J~J SY'-q~'~ Results (pass/fail) SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot ~/0 0 ~ ' To building foundation /0/"~' On adjacent lots ~---~C> r~..- Surface water /~--~ 0 /'.'~' Curtain drain /JotJ~: ~]~/,.J System type Total depth /, ~"" ,Depression over field (Y~) for ,/(~[/~r' ,Bedrooms' · After test If yes, give date fO//~J Onadjacentlots /00 ~ Propertyline //0~'- TO existing or abandoned system ~3n lot '~'//~ Cutbank~O ~ '- ' - Water mai~se~ line /0 f~ Driveway, pa~n~ehicle storage ama /~ ~ E. ENGINEER'S CERTIFICATION I cer~fy that I have checked, verified, or confcrrned to alIMOA and HAA guidelines in effect on the date of this inspection. Signature ' ' ' Engineers Name HAAFeeS - >DO,/_~ , , WaiverFeeS Date of Payment ~'-~;~,~-~ - 7.z~- Date of Payment Receipt Number ,~04/ /"~' ~'~'F Receipt Number. 72-026 (3/93)° Back