HomeMy WebLinkAboutMCKINLEY VIEW ESTATES BLK 2 LT 10 Municipality of Anchorage Page Development Services Department Building Safety Department On-Site Water and Wastewater Program, 4700 $. Bragaw St. P.O. Box 196650 Anchorage. AK 99519-6650 www.cLancflorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW000327 PID Number: 05:1-792-14 Name: Linda Longnecker Wastewater System: New [;~ Upgrade P.O. Box 877270 Wasilla, AK 99687 ABSORPTION FIELD 688-:1236 Three (3) aO.~T~.~ aS~,T,.~ n.. LEGAL DESCRIPTION .8 c~o~e 8 2 10 McKinley View Estates 7 ~. 1 .5 ~. 100 w.,,: [] New [].pgrade 5 .. Class A .. F,.575 r~ ASTM D3034 PVC F,.MM&M Contracting: 9/30-10/4/2000 ¥.: c,~l e.,,,, s..: ..i c.~, .,~.,o.. c,..~:,~ TANK SEPARATION DISTANCES Ig sepuc n Holding n S.T.E.P. r-I Other:.  SepUc AbsorpUon Lift Holding ~bllc/Pflvate ~ac~e~: Tank Field Stafio~ Tank S~,~U~ Anchorage Tank 1,000 w., >:100 >100 N/A N/A >100' Steel Two ~w... >100' >100' N/A N/A ~ / LIFT STATION ~. >5' >:10' N/A N/A/~ ~": o.,. .,.,~o. >5'. >10' N/A N/A ~,. ~,. . c~,,~. None Noted ~"~"~'"~ "'""~: BENCH MARK t. XlStlng beptlc lank Removed ~rom ~ite. Lot is c ..... ,~ =,, owc,n ~ 2!0~97. &--xl'~r'~'J& 'T"n,,,~ Concrete Stoop at Base of Steps Engineer's Stamp Inspections performed by: MEA Dates: 1" 9/30/00 2"~ :10/4/00 .... - · .'-~-'~.~,, Department of.. ,/ .~ Health and Human.,,~ ~,_Services approv · ..... Municipality of Anchorage Page 2 of 3 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DMSION P.O. Box 196650 - Anchorage, AK 99519-6650 - 343-4744 On-Site Wastewater Disposal System or Well Inspection Report Permit Number SW000327 PID No. 051-792-14 A Sl 25.6 25.8 S2 30.9 30.5 C3 59.1 40.1 M1 37.2 58.2 M2 68.1 54.7 C4 37~ 58.2 C5 68.1 54.7 LEGEND S - Septic Vent C - Cleanout M - Monitor Tube SV : - Splitter Valve' $1 c: PLAN AS-BUILT SCALE 1" = 40' Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAl. SERVICES DMSION P.O. Box 196650 - Anchorage, AK 99519-6650. 343-4744 On-Site Wastewater Disposal System or Well Inspection Report Page 3 of 3 Permit Number SW000327 PID No. 051-792.14 16' 93.t Drainfield 92.0 99.1 Geotextile · ' ~abr~c .... ' ' · PROFILE AS-BUILT 1" = 10' q;¢;;.;~ ..... ,;;~ ~ · MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage. AK 99519-6650 (907) 343-4744 IO- ® ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Aug 24, 2000 Expiration Date: Aug 24, 2001 Permtt Number: SW000327 Legal Description: MCKINLEY VIEW ESTATES BLK 2 LT 10 Design Engineer: 0014 Anderson Engineering Owner Name: Country Realty Owner Address: PO Box 670495 Chugiak, AK 99567- Parcel ID: 051-792-14 Site Address: 022519 CENTURION DR Lot Size: 20087 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. Ail requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Date: - 24- O0 FAX MEMO TO: WITH: FROM: DATE: SUBJECT: Dan Roth DHHS Mike Anderson September 29, 2000 Lot 10, Block 2, McKinley View Subdivision Septic System Design MESSAGE: The groundwater .level .In the test hole for this Job is at 12.5' below the ground · surface. This is a more accurate reading than shown on our test hole log because that reading was taken after heavy rains and the looseness of the test hole soil.pro, bably attracted the mols. ture from the heavy rains the entir6 week of the momtorlng period. The level is now stabilized and appears to be more accurate as we are approaching the normal high ground water period for the year. We need to mo.d. lfy the design of the ab.so, rptlon trench due to the elevation of the service line exiting the house. The ongmal septic.tank has failed a,nd must be replaced. Unfortunately the Inlet of the tank i.s ap. proximately 6.5 below the ground surface which means the distribution p~pe in the trench must be at 7' below the surface. The total depth of the trench will be 8' which allows a 4.5' buffer to ground water. Two trenches will now be required each 50' long and 5' wide. We are unable to u.se a flow divider because.it requires a 6" d~op in grade whlch we can't achieve in this case. Please rewew the attached design and modify the permit accordingly. Thanks. 2 Pages B~ing Transmitted. Please call 522-7773 if there are any problems. Z/I 'd 8~69'0N ~dlO:Z 000~ '6Z'deS. L.e--r- lC), /~'~. ~3 ooo ~?~7 Z/Z 'd 8Z69'°N :.. ~d~O:~ 000~ '6~'deS ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 (FAX) '.. August12,2000 Municipality of Anchorage . . Department of Health and Human Services 825"L" Street ' Anchorage, AK 99502-0650 Subject: Lot 10, Block 2, McKinley View Estates Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Eng~neen The existing absorption tren(~h currently serving the three bedroom home on the subject lot will not pass an adequacy test and cannot-be certified for a Health Authority Approval. We are therefore applying for a permit to construct a new septic system on the lot to serve the home. The attached Site Plan and backup documentation identify the location and configuration of the new septic 'system and the parameters used in the design. The subdivision is currently served by a community water system so separation distances from the water service line are easily met, The existing septic tank will be uncovered, inspected and vedfied for continued use. It will be replaced if it is found to be leaking or structurally defective. . A test hole was placed on the lot in the area of the new absorptio~ trench. Silty sand was encountered with some gravel. The material percolated at a rate of 15 minutes per inch. Groundwater was not encountered in the excavation but did develop at 11' below the surface during the monitoring pedod. We have therefore designed a 5'. wide absorption trench with 3' of gravel beneath the distribution pipe. The total length of the trench will be 64'. The total depth of the trench from original grade will be 6.5' which will be a minimum of 4.5' above the present level of the groundwater. The ground surface on the lot is very fiat with only a moderate slop~ toward the east. ' The new trench will be constructed parallel to' the contours of the surface in . conformance with Municipal requirements. Grading will be acccmplished to assure surface drainage is away from the new trench. The existing absorption trench will be abandoned in place as it is more than 8' in total depth from the surface and apparently encroaching into the 4'. separation required from groundwater, If the system is con{tructed in accordance,with our design the following statements apply: . The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. Lot 10, Block 2, McKinley View Estates August 12, 2000 Page Two 2.. Th(~ system, if constructed as designed, wiil have no adverse impact on existing septic systems in the area or those to be constructed in the future.. ' ' ' 3. The system, if constructed as designed, wili 'hav~ no adverse impact on reserve space,.either surface or subsurface, on any lots located in the area. 4.. The system, if constructed as designed, will have no adverse impact on drainage pattems in the area. The current drainage pattern will be maintained. Sincerely, . II '11 II I I THIS P ~75.66 ! ./ I / / ./ · 13 / ' /' ./ / / . · ! / AREA MAP SCALE 1' = 100' /. / /. / /' / / / b SCOPE OF WORK: 1. Verify the Foundation Cleanout. Place New if Necessary. 2. Verify Existing Septic Tank for Continued Use. 3. Place New 1,000 Gallon Septic Tank if Required. 4. Place 2 Post Tank Cleanouts. 5. Construct New 64' Long X 5' Wide X 3' Effective Depth Absorption Trench. 6. Abandon Existing Absorption Trench in Place. 7. Regrade All Disturbed Areas. 8. Revegetate Area As Required. SITE PLAN SCALE 1" = 40' ~ctive De' LOT 10, BLOCK 2, MCKINLEY VIEW DESIGN FACTORS: SYSTEM REQUIREMENTS: Three Bedroom Home 5' Wide Trench System Perc. Rate: 15 Min./Inch 1,000 Gallon Septic Tank Application Rate: .8 GPD/SF 3' Drainfield Rock 3 Bedrooms X 150 GPD 1.8 GPD/SF = 562.5 SF of Absorption Area 562.5 SFI5 LF (Width)*.57 (Red. Factor) -- 64.1 LF Trench Length Therefore: Construct 64' Long X 5' Wide X 3' Effective Depth Al~sorpfion Trench. Flowline Elevation in Trench to be 3.5' Below Original Ground Surface. Total Depth to be 6.5'. Mound Over Trench to Provide Minimum of 3' of Cover. NOTE: TYPICAL WIDE TRENCH SECTION , . (NO SCALE) · Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 10' Separation From Lot Line. Minimum 4' Separation From Groundwater. Municipality of Anchorage Department of Health & Human Services 825 L Street, Anchorage, AK 99502-0650 SOILS LOG - PERCOLATION TEST Performed For: ~ Legal Description: Lot 10. Block 2. McKinley View Subdivision 3 4 5 6 7 8 9 10~ 13 14 15 1E 17 18 21 OG/OL Some Gravel Was Groundwater Encountered? If Yes, What Depth? Depth to Water After Monitoring Date:' Bottom of Test Hole SLOPE North South No 11' ' 8/7/00 ,~ ~. ~'~,Jj .L~. ....... ~',,. --¥ ~..~4..-1"-[' ~5: ~ y.../,~_ ..,~:~.....,~.......?.,~,~; ._:,,;.. ~ - Date Performed: -..."' SITE PLAN S 0% L O P E Reading Date Gross Net Depth To Net Time Time Water Drop I 7-Aug 12:30 10" 2 1:00 30 12" 2" 3 1:01 9.5" 4 1:31 30 11.5" 2" 5 1:32 10" 6 2:02 30 12" 2" Perc. Rate: 15 Min./Inch Perc. Hole Diameter: 6" Test Run Between 4.5 Ft. and 5.5 Ft. Comments: Perc. Cavity Presoaked Prior to Test. Performed By: Tim Kimbrough, I, ~ Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 8/7100 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 10, BLOCK 2, MCKINLEY VIEW ESTATES SUBDIVISION GENERAL: The scope of this project includes the placement of a new foundation cleanout and the verification for continued use of the existing 1,000 gallon septic tank. If the tank is found to be unsound the work will include the procurement and placement of a new 1,000 gallon septic tank at the location shown on the Site Plan. Work also includes the construction of a new 64' long X 5' wide X 3' effective depth absorption trench at the location shown. Distribution pipe will be placed at 3.5' below the odginal ground surface. The total depth of the trench from odginal ground will be 6.5'. Mounding over the trench may be required to provide a minimum of 3.0' of protective cover. Construction shall be in accordance with the approved site pla~, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation o--f affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,000 gallon septic tank must be be procured from an approved source and installed at the location shown on the plans if the existing tank is found to be unfit for continued use. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include Ko 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. · Lot 10, Block 2, McKinley View Estates August 12, 2000 Page 2 of 3 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. Contractor shall vedfy the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trenches to drain away. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). ' ' Lot 10, Block 2, McKinley View Estates August 12, 2000 Page 3 of 3 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfllled. The second inspection must be conducted after the placement of the geotextile fabdc, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME /~i ~ LEGAL DESCRIPTION LOCATION IInside length -EW P~'r '~-~N~ ~E~ {.~PG RADE NO.~_.~EDROOMS Dwellingc~ ~_..~ / PER-MIT_NO. __ ,o. of co~ynt, Liquid depth IDwelling PERMIT NO. Material [Nearest lot ,in~_~,~ ~- / ~ ~-~d~ . / , Foundation%~, / Liquid capacity in gallons -:~~tion area PERMIT NO. DISTANCE TO' t we/g/'~ _ Man u factu re,r/~ ,~ J Liq'tz~t ~al'~~ IF HOMEMADE: ~,s,..c~,o: I"~'' i~umur.r -- Wel ~ - ~~C~TO: / ~hnes~ ~ Length ~li~e ~ [~~ Top oftile~o finish grade ~ Width' Type of crib ~ ~~TO: w~ Depth Crib depth Total effective absorption area Building foundation Nearest lot line Driller Distance to lot line PERMIT NO. Sewer line Septic tank Absorption area(s) OTHER PIPE M AT E R I/~.~LS INSTALLER APPRO~~) ~_o,~,.i,,l~,~ m~ DATE~ LEGAL I--1 L~ tP,t C: DEPFtR'!'MENI" HEALTH AND FN','IF.'nNMENT~L F~TEF:TInN 8;2 ..... '"L'" STFEET, At'-,CHORFIGE., FIk'. :.~ .......... e,- CONST ,::SAL RRELLO) F'O BOX 207:1.. E.R. 99577 '69¢.~4169 HFFL [ _.HN I ~,.~.:, L 0 E: R T i 0 N LEGFIL LiS B2 MCKINLEY L]~. ¢ ~ ~.%~.,;,¢:*~n~c~ ............. ~ LO]" SIZE '9'~'~9'~q~ qptlRRE FEET T'-r'E'E OF SOIL FIE:SORF'TIZN z,¥z, TEH IS: TRENCH MRXIMLH t'IUME'ER OF EEDRCEHS = ~: SOIL.. RATING ,::SL.] FT,-"BR)= THE REPl IF. tED SIZE OF THE :.LIL HE, z, UF..PFILN SYSTEM THE LENGTFI DIMENSION :ES THE LENGTH ,.'.'IN FEET::, OF 'THE TRENCH OR DF:AINFIELD. '' -' IS . -"1 THE DEPTH ElF R TF. EN_.FI OR PIT THE DISTAHCE E, ETI.~EE.I-,. THE SURFACE OF THE ........ "'lTM - 3Rl~ NJ':, AND THE E:RTTF~M ElF THE E,.,...HCMTIJN (IN FEET', THERE tS NO SET WIDTH FOR TRENCFIES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OLrFFALL PIPE AND THE E:OTTOM OF THE E',dfZ:RVFiTION ,:.'IN FEET). t I .' ~j PERMIT AF'F'LICRNT HAS THE F:'E_-,F_N.:,IBILIT.r TO INFORM THIS [:,EF'RRTMENT DURII',IG THE INS'T'ALL.ATIEd'.~ INSPECTIONS OF FINY .WELLS AD TFIZENT TO THIS F'ROPERT'¢ FIND THE NJMBER ElF RESIDENCES TFIRT ]"HE WELL WILL SER',,,'E. BACKFILLING OF FINY S'.r'STEM WITHOUT FINAL INSF'ECTION AND RF'F'RO',,,'AL BY TFIIE; DEPARTMENT WILL BE '.--;IIB.¥EF:T TO FRO::,EL. UT.uN. MINIMUM DISTANCE BETWEEN A WELL FIND FtNY ON-SITE SEWAGE DISPOSAL. SYSTEM IS 100 FEET FOR A PRIVATE WELL OR t50 TO 200 FEET FROM A PUBLIC WELL DEPENDING UPON THE TYPE OF F'UBLIC WELL MINIMUM DISTBNCE FROM B PRIVBTE WELL TO A PRIVATE SEWER LINE IS ~5 FEET BND TO FI COMMUNITY SEWER LINE IS 75 FEET, OTHER REQUIREMENTS MAY FIF'F'LY. SF'ECIFICATIOI'.,IS AND CO!'.,ISTF.'.LICTION [:,IRGF.'RMS ARE R',,,'RILABLE TO INSURE PROPER INSTALLATION. I CERTIFY THAT ::L: t AM FFIMILIFIR WITH ]"HE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS RS SET FORTH BY THE MUNICIPRLIT'¥' OF FINCHORRGE. 2: I WILL INSTALL THE S"r'STEM IN ACCORDANCE WITH THE CODES. 3: I UNDERSTRN[:, TF'IAT THE ON-SITE SEWER SYSTEM I"lFf¥' REQU2RE ENLFIRGEHENT IF THE RESIDENCE IS REMODELE[:, TO IN. CLUDE MORE THAN SIGNEr.,: .......2__'x_:£ .... ;- - ~.;"?.. ............................ AF'F'L I CANT FI&S COt'-,I:;T (';AL FIRE[ LC :, ,-,- ., ,,~ ' ::' ( "',: ': /- . ~l~ssell Oyster 694-2774 O&E Performed for: Narne:. ENL~,NEERING & DEVELO, Box 90, Davis St., Eagle River, Alaska 99577 694-2774 or 688-2280 MENT CO. SOIL LOG Tel. No._ Mailing Address: Legal Description: Earl Elil~ 688-2280 Depth (feet) 1__ 2__ 3__ 4__ 5__ 7__ 8__ ~10 __ 11__ 12____ 14__ 16____ Soil Characteristics Ground Water Encountered: Yes.___ Proposed Installation: Seepage Pit Comments: _ No__ If yes, what depth Drain Field__ PLOT PLAN PERC. TEST Performed by: Date: SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG- PERCOLATION TEST PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: 2 DATE PERFOR[VIED:_O[:~' ~'~r LlO SLOPE SITE PLAN 10 11 ENCOUNTERED? 1 2 IF YES, AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time ¢~,i~'~ Water Drop ;~ f~ ~ ~ , . 14 15 16 17 18 19 20 PERCOLATION RATE ~ [ r~ (minutes/inch) TEST RUN BETWEEN . ~-- FT AND 2 '~/'~_ FT 72-008 (6179) ALASKA WAS GROUND WATEfl ENCOUNTER£-D? IF YES, AT WHA, T DEPTH? 5 6 7 8 9 10 1/ t2 13 14. lfi 17, 20- 'tH g Gross Net Depth to Net I If;adiP9 Date Time Time Water Drop PERCOLATION RAFE ..................................... (minutes/inch) TEST RUN BETWEEN FT AND FT PERFORMED BY: ~ eer,{ GEFITIFIEt3 BY: I)ATE: APPLI( ,NT FILLS OUT UPPER HAl ONLY Property0wner ....~-/~.~...~/~.~._ x,~.~f~ ~/~i~,'~A ~.~ ~~ ...... Phone Address ,~ ~ '~ ~.~ ,( ~.~ .~,~,.~. ~ ~,/~. Zip Code Lending Institution ~ / ~ ~ // Phone Street Locati~ A//&: '~ ' ' ' '" ' - Type of Resi~nce ~Single Family ~ Multiple Family No. of Bedroo~ ~ Other Water Supply ~ Individual A~ACH WELL LOG. A well Icg is required for all wells drilled since June 1975. ~ Community For wells drilled prior to that date, give well depth (attach Icg if available). ~ Public Utility Sewer Disposal ~ Individual Year individua[ ~nstafled: ~ Public Utility When Connected to Public Utility: ~ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH RE~EST BEFORE ~OCESSING CAN BE INITIATED. Time Time Time Time Date Date Date Date Inspector Insp~tor Insp~tor Insp~tor Field Notes: ~/~I]i~ICtPAI~TY OF l)!~)~' ,- ,, ~:h[Vl:;: .), 4,', ,:: ............ , ::: : ( ) DIS~BOVED ( ) CONDITIONAL APPROVAL* O*T~ /~. ~_ ~ ¢ Z.~ Soils Rating Date ~wer Installed Well To Absorption Area Well Log Received [~ ~ Z Well to Tank Septic T~k Size 72.023 ; - .,.'- . ,.*:.- ,Department of Health:and Human.Servmces :.,, .: .,- . ,., , ~ . ., ~ .. .......~.a,~.~..a~, . ...,,.~ i , ,.. -: ...... ,~ ..... ·. CERTIFICATE OF H~bTH AUTHORI~, APPROVAL ...... Cu~ent Prope o her s LlndaLongn~ker .... ,'. ','. .... Da one ~1236, , Mailing address · P.O. Box8~270.,Wasilla,'AK99687; : .- ....... ',, '. Mai~i~g add[ess'.' ' + J IE"-SA" nt"' ' ' ' " "' ' ' ' "' ' ' "/'""" " ' "'" : Un ss othe~is~ ~ ested, ~ willbe ~Id by DHHS rp kup. ~ picked up b~ .... "OMSER OF BEDRoOMs: 3. '. TYPE OF WATER SUPPLY: -. Individual Weli ,, . Ind!vidua_l Water S!orage.. ; Community Cla~s_A-Weft Public Water System 'th ~ (3) .... ' ' ' .TYPE oEWASTEW~TER DISISOSA~.; , - ', '. Individual On-s -," , Indi~iduAl Holding t~nk,'." "' '" E]: · CommuntyOh-site *' , ' '- E]~': "' "' Public Se{ver E]: The Municipality of Anchorage Department of Healih and Human Services (DHHS) Is~;ues Certificates of Health Authority Approval (I-IAA) based only upon the rep~:esentations given in paragraph 5 by an Indel~n. deht pr0fessk{nal, , civil ~ngineer registered in the State of Alaska. Certificates of Health Authority Approval are'required for th~ trar~sfer, ', of title (except between spouses) on propedies served by a single family on-site waste~ater disposal and/or.water . supply system.' DHHS also issues HAAs upon'request to home oy~ners: Certificates'of Health'Authority Approval", are valid for 90 days from the date of issue for properties served by a pdvate or Class C ~/ell and may be reissued · with new water sample results less than 30 days.old. Cedificetes are valid for one year for properties served by Class A'or B wells or a public water system. The. Municipality · of Anchorage is not respons~le fo~: errors or, , omissions in the professional engineer's work. . '5.- STATEMENT OF INSPECTION BYENGINEER :. ;,.;-: . '~ ;,'/. ',". - · .... ", ~,~ c~--tified b~ 'mv"~:,~al ~ffi~ed h~'~t~ a~'~d'~ ;of ~ valMation date sh~ ~197 I v~ ~at,my r ~;~ ~" '~ ~"~ '~h '~ i~t~ H~ th ~Au~ ~proval Gu~d~nes f~ th~s ~lth · '- · - '*. ' ' ................... t ater d~s a ,s tem'~s ~fe..~ncbon~ '~h~h~ ~'~ h'U~f ~ ~hd ~ of ~cture i~d~t~ herein..~ m~,v~ nfn~t ~n* ~bta h~ fr~ t~ Mu~ c ~ ~ of ~a~ files'and from my investlg~fion pnd m~bpn. ~e sit~'W~t~'s~olv ah~ ~te~ater'd sposal system ~s in ~mpha~e ~th all ap~ble. ~umc~pa~,~nd Name of F~rm. ~demon Enflmeennfl.: ........ "' '" ~''' ' -'~ ~'~'; "' :. *P~5~ev'5~-~3 . r ss P..B ~ chom ,,, .:.,. Eda nee~ PHnted Name '-. Michael E. Andem6n. P.E. "- - ~ . . Date '- ~10101 . . . .... , . . ~, . .~..~ ~~ ~~...~.y..~..,~,...~-.t...'~ . . 6. DHHS SIGNATURE , ' 4t~,:.. ....... :.~e~ ' Approvea~or, .'J- Dearooms,: ' , . , , · :.' , ~ ',..?~t~- . · Disapproved.' ~ · : ,'. · ,,.'. ' · :' · ', ;, - .' , 'bed ~ tip rooms with the f611owing s utations: .r. . Conditional approval for ..... Additional Commen~s Attachments: HAA Checklist Septic System Advisory Well Flow Advisory Expiration Date: L.~ , I I ~ (~ev. 1(~) X Maintena.nce Agreements Supplemental Engineer's Report Other Original Ceflificate Date: /-//- //- ~ I Reissue Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Pragmm 47OO South 81~gaw SL P.O. Box 196650 Anchorage, AK 99519-6650 www.ci,mx:horage.al~us (go7) 343-?g04 HEALTH AUTHORITY APPROVAL CHECKLIST Legal De~atplkm: Lot t0. Block ~, Uddnle/View Eot~te~ A. WELL DATA wea type C~uA. Talal depth -- Be If A. e. ar C pmvlde PWSID # 211~"97 FROM W~ i LOG Date of tes~ StaUc water ~ we~ ~r°%~an WATER ,~IPLE RESULTS: Cdiform calonles/100 mi. Date of sample: SEPTICMOLDING TANK eATA Tank TyTm/Matmlal Steel Ta~tk size 1,000 gal. Date of pumping ABSORPTION FI~,.D DATA ft. g.p.m. Number of Campam'nente Z Dalxession over tank (Yfld) N ~ mUng (g.p.dJf~ ~ ft2A:)drm) · GPO/SF Wiclth .5 ft. CJ Length t00 Tc~al depth ~ ft. Parcel ID: 051.T92.14 wea tog (Y~) Wires.properly protected (Y~l) casino heght (above eround) AT INSPECTION ft. g.p.m. aeanou= (Y/N) y High water alarm (Y~I) N System type 5' Wlde Tfendl Gravel t~ow pipe 1 Eft. e--hs'~P-- tJon ama 575 ~ Monitoring tube Y Depression Qver field N Re~u~ (Pas.~FaU) Fluid depth in absorption field before test in. Wate~ 8dded gal. Elapsed Time: min. Iqnal fluid depth in. AJ3~orpaon rate Any rejuvenation treatment (past 12 mo.) O'/N & t~tpe) N Far bedmams New deplh in. g.p.d. If yes, give date N/A D. MFT S'rATION Date installed 'Pump on' level at in. Datum F_ SEPARATION DISTANCES 'Pump off" level et Cycles tested SEPARATION DISTANCES FROM WElL ON LOT TO: Septic tank/lilt station ~n lot N~scxption rmld on lot Public sewer main Manhole/Access (Y/N) High water alarm level at Meets alarm & ~ n~luf~eme~ts? On adjacent lots On adjacent lots Public sewer manhele/deanout Holding tank Property line ,>10' Water Service line >10' Curtain (hain None Noted F. COMMENTS SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:. Building f~undatlon >5' Pro~ line Watermaln.4UA' [~'~ '~'~' Water sewlce line >10' Wells on adjacent lots >100' SEPARATION DISTANCE FROM ABSORPTION F;;~ n ON LOT TO:. Bullding foundation >t0' Sur~ce water >100' Wells on adjacent lots >100' Water main >t0' ~, parta~hUe storage >25' Waiver Fee $ Date of Payment Receipt Number Receipt Number {Rev.