Loading...
HomeMy WebLinkAboutMCMAHON BLK 3 LT 5McMahon Block 3 Lot 5 #017-042 05 '.Municipality of Anchorage Page I of '~ . DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage. Alaska 99519-6650 · Telephone: 343-4744 On-Sile Waslewaler Disposal Syslem and/or Well Inspection Report Permit Number: ~'1,4,.) OO0~) I(:~ PID Number: I~am.: d~ 5~--~'*h" 1+~ Waslewaler System: ~New D Upgrade '~'EO0 F.,~.~[¢~.~ ~o~ ~.,~.~,~ SI~ ABSORPTION FIELD LEGAL DESCRIPTION so,,..,,..- ~, ~ ~.o,sq WELL: B New B Upgrade G,..~ ~ld.,: ~ F~. I ~ ~t. " , · ~oPuI ~n~p~w~ ~-I ~ .. TANK SEPARATION DISTANCES Ks,,,= o tlolding a S.T.[.P. SuHace Waler I~ I~ -- T STATION Remmks: BENCH MARK Top ...,,~ ~..v.,,o.= 5 & S ENGINEERING 17034 Eagle River L~ R~d, NO.~ Deparlmenl ol Heallh and Human Services approval Reviewed and spproved _ ~. ~ O~te: /'//' 0 i PERMIT NO. SWO00010 PAgE. 5 O~ 5 Nunicip. alit oF DEPARTNENT OF HE~_THAND HUMAN SERVlGES ENVIRONMENTAL SERVI£ES DIVISION p.n. Box 196650 eAnchorage, Alaska 99519-6650 e Telephone: 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LEGAL LOT 5, BLOCK 5, McMAHON S/D P.1.D. NO. 017-042-05 ST1 FINAL GRADE/ MT1-85- .2'-~ Si~,- 98.9' NEW 1250 ~ GALLON SEPTIC TANK C01=97.9' __C02=96.6' A NO WATER FOUND ?6.7' B.O.H. A B FCO 5.0' 76.0' ST1 17.0' 87.5' ST2 24.0' 90.0' DBL1 52.0' 92.5' DBL2; 55,0' 95,0' C01 42.0' 89.0' MT1 68.0' 74.0' C02 72,0' 75.0' PERMIT NO. SWO00010 PAGE 2 Or 3 _.Municioa[itv o? AnchoraQe DEPARTMENT OF HEALTH AND HUI~AN SERVICES ENVIRONMENTAL SERVICES DIVISION p.n. Box 196650 ~._Anchorage, ~aska 995[9-6650eTe. i.e. phone: 343-4744 ON-SITE WASTEWATER DISPOSAL ~YSTEM AND/OR WELL INSPECTION REPORT LEC.~L LOT 5, BLOCK 3, McMAHON S/D P.I.D. NO. 017--042-05 100' W 0 GRAVEL DRIVEWAY SEPTIC 'ANK~ ~: ~ ~ I r~ ]0'DRAIN~T ~Nf ........ J r,] ~~ ~ /~,~.=/~--=~ .... ' ,,,.~...?:~.=~ From : R_P[t,,E DRILL 907 ~45 0202. 0ct.'t6.20{~ 1~4:44 g~M Municipality of Anchorage Department of Health and Human Services 825 %' Street P.O. Box 196650 Anchorage, Alaska 99519-6850 Rick My~from htlp://www.cl anchorage ak.us Mayor Permit Nu tuber: f/SW 000010 Date of Issue: 2.1.00 Pa r'el Identification ~mb~n' Date Completed: 4.26-00, ]s well located at approved p~mit location? [] Y~ [] No Date Started: ~ PrepeHy Owner Name & Addre~: Borehole Dm: Sell Type, Thief, ness & Water Strata McMahc~n BIk 3 lot ~ Jeff Shuttz f2500 Furrow Creek Raad J:rom '1'o. stick-up sandy silt silty gra vel gm vetly s#t silt gra rally silt silty wa fer sand end gm vel silt gravelly silt water sand & gravel 0 2 2 18 18 31 31 77 77 85 85' 105' 105 117 f17 125 f25 182 102 187 RECEIVED OCT 19 2000 ,.-'- Method of D~illing [] air.rotary E] cable $,ool C~slng ~ype: s~eel Wail ~ickness: ,025 inches Dia~ter: ~ inches Depth: 187 f~t Lin cr Type: Diameter: ~ inches Dcp~: feet Casing sfickup above ground: ~ f~t 'S~t~ ~ter ~el (from ground level}: ~f~t Pumping kvel:/8?.fcct ~ ~ ho~s pump~g'~ gpm R~e~ Rate: ~ ~m M~od of Tm6ng: 9/r ~. Well'Intake Openi~ ~ Open E~ ~ (~ Hole ~ P~orations -S~n f~ Smp~ f~ Groul Type: bentonite ~ 8 Volume: 1 Depth: Sart~ feet Pump: Intake Deplh Pu~ size hp Btam ~a~ Well Dislnf~ Upon Completion? ~ Yes ~ MethM of. DiSlnf~tion: OIo~np Comments: Wall Dr~ler: Atp/ne D~ing ~ Enfe~Eses PO ~x ~10496. ~nohomge, AK 995~ ~ Attention: The well driller shall provide awc]] log to the property owns- within 30 days of completion and thc properly ROBERT C. COWAN, RE, ROBERTA. SHAFER, RE. CIVIL ENGINEERS (907) 694-2979 FAX(gO?) 694-t2! I Municipality of Anchorage DEPARTMENT OF HEALTH~/~D UUMA_N SERVICES 825 L Street P.O. Box 196650 Anchorage, Alaska 99519-6650 4 REFERENCE: The septic in~pgctions for t~% referenced property were performed on ~/A/o0 and ~/$/00 . Prior to submitting the On-site Wastewater Disposal System and/or Well Inspection Report we are waiting for the ~w~r,,~ ~ to be completed. If we may be of further service please contact us. Sincerely, Robert C. Cowan, P.E. :7034 NORTH EAGLE RIVGR LOOP ',' SUITE 204 ', EAGLE f:~VER, N. ASKA 99577' MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON.SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: Feb 01,2000 Expiration Date: Jan 31, 2001 Permit Number: SW000010 Legal Description: MCMAHON BLK 3 LT 5 Design Engineer: 0003 S & S Engineering Owner Name: Jeff Schultz Owner Address: 12500 Fun'ow Creek Road Anchorage, AK 99516- Parcel ID: 017-042-05 Site Address: 012600 FURROW CREEK RD Lot Size: 36629 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All consthJction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: ~,~..- /- O ~ January 12, 2000 ROBERT C. COWAN, P.E.. CML ENGINEEr~ (907) 694-2979 FAX (907) 69,4.1211 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 Anchorage, AIC 99519 REFERENCE: Lot 5, Block 3, McMahon S/D It is requested that you Issue a permit to drill a well and install a septic system to serve the four bedroom dwelling on the referenced property. A test hole was excavated and a pemolation test was performed. The approximate location of the test hole is located on the attached site plan. At the time of excavation 9/20/99 water was not found. We do not anticipate any adverse effects on neighboring wells, septic systems, reserve areas or drainage patterns by the installation of the proposed septic system. The construction of this system will not prevent any future development on any of the adjacent properties. If you require additional information, please contact us. Sincerely, Robert C. Cowan, P.E. RCC/jhm Enclosure 7034 I'~tORTH EAGLE RIVER lOOP · SUITE 204 · EAGLE R1VER. AJ_A~KA 99577 LOT 5, BLOCK 3. MoMAItON S/ DEStC,N CRITERIA. /~ ~'--~oo.~,~ U,,L.T, ,L ., ( Srllllg 4 BDSM =~ 600 GPD ~ P~°~-.~'" ^v^n°, .,,.,.~/..'~'./.~..,.~ SOILS',= 1.2 GPD/SQ.FT. 600/J.: ~ 500 SO.FT. REO'¢ T ~m 6.o' EFFECTIVE ~ I~ ~1 . I ~ ,~ ~1 ~ AREA X ~ ~/~ ~l ' J ' i~-q[ ~ ~~ ~oo, J ~' j ~ / WELL ~ - -_~,____~ _ 10 UTIL. ~ DRAINAGE ESMT. [ Municipahty of Anchorage. DEPARTMENT OF H~L~H & HUMAN SERVICES · 825L Strut, Anchorage, Alaska 99~2~50 SOILS LOG -- PERCO~TION TEST PERFORMED FOR: ~r 5~U~ ~ DATE PERFORME LEGAL DESCRIPTION:Lo~ ~ ~L~C~ ~ ~ Township, Range. Section: 4- 5- 6- 7- 8- 9- 10- 12- 13- 14- 15- 16 17 18 19 20 WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? -- po E I)epa to Wat~' ~ter D~.y Idonitm'in~? A Reading Date Gross Nat De~th to Net Time Time Water Drop S o - . ' - ~ " ~O ~ IOvz'' ~" PERCOLATION RATE J~ ~ ~) (m~nutes~lnch) PERC HOLE DIAMETER TEST RUN BETWEEN ~'~ FT AND '7 FT COMMENTS S & $ ENGINEERING .~,./~/~-~ ,~ ...... ~ ........... r .......... ,~ .... J CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITI=HI~[e~.~t~,~I'E~[%~lt~IU~FAL GUIDELINES I" EFFECT ON THIS DATE. OAT~ ~ / ~ ~ / q ~ 72~ (R~. 4/~) ROBERT C. COWAN. P.E. CIVIL ENGINEEV~ (907) 694-2979 FAX (907) 694-121 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS REFERENCE: Lot 5, Block 3, McMahon S/I) January 1~, 2000 GENERAL: The scope of this project includes the installation of a new 1250 gallon septic tank and a new ~'eneh to serve the proposed four bedroom residence located on the referenced property. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The contractor shall be responsible for obtaining any necessary underground utility locates. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed fi-om soil settling. Contractors installing wastcwater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. SEPTIC TANK INSTALLATION: A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. t7034 NORTH EAGLE RIVER LOOP * SUITE 204 ,, EAGLE RIVER, AJ_A~KA 99577 Page 2 Lot 5, Block 3, McMahon $~D Janue~ 13, 2000 All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. Septic tanks installed with less than 4 ft. of cover shall be insulated. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCII/DRAINFIELD INSTALLATION: Excavate the proposed trench to the dimensions shown on the design. The bottom ofthe excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (roffed-up) before gravel (sewer rock) placement. Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. I~ag® 3 Lot 5, Block 3, McMahon $~D Janua~ 13, 2000 MINIMUM MATERIAL SPECIFICATIONS: 1. Any septic tank proposed for installation must be constructed by a Municipal approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe Perforated Solid Cast Iron Yes Yes ASTlVl D3034 (PVC) Yes Yes ASTIVl F810 (HDPE) Yes No ASTM D2~62 (ABS) Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. Insulation shall be at least 2" thick exlxuded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements, which ever requirement applies. Page 4 Lot 5, Block 3, McMahon $/D January t3, 2000 INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: 1. The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. 2. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. 3. The final inspection is to occur upon final grading ofthe property. Often there will be more than these 3 inspections required. Especially with the installation of .multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer ~s to be contacted at least 24 hours prior to the start of construction. If necessary, a pre- construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR/INSTALLER / i ]l ality of Anclior. ~Ir.~} Department of Health and Human Services ~ P.O. Box 196650 Anchorage, Alaska 99519-6650 PJck My~rorrl htr p:l/www.ci.a nchorage.a k.us ' Mayor Permit Number: #SW.O00010 ,-Date of issue: 2-1-~. Parcel Iden*ino~tlon .Number: D17-0~2-05 Date $tarte~.: ~ Date Completed: 4-26-00 Is well located at approved permit location? [] Yes [] No Legal DescrJptio~_. McMahon Big 3 lot 5 Property Owner ~me & AddreSS: ~ 12500 Furrow Creek Raad ~4ncho~Oe;, Ak 99616 Depth (ft) From To 18 31 3I 77 77 85' 85 10E' 105 117 117 125 125 182 182. 187 Borehole Data: Soil Type, Thickness & Water Strata st/ck-up sandy silt silty gm vel gravelly silt silt gravelly silt silty water sand and gravel silt gravelly silt water sand & gravel gECi ,. '3 MAY 24 2000 Dept. Health & Human Method of Drilling'l~ air rotary i'3 cable tool Casing type: steel ' Wall Thickness:,025' inches Diameter: _~ inches 'Depth: 187 feet Liner Type: Diameter: ~ inches Depth: ~ Casing stiekup above ground: -2 feet feet Static water level (fi.om.ground levcO: .69 feet Pumping level: 187 feet after _2 hours pumping 5_.._Ogpm Recovery Rate: 50 gpm Method of Testlng: ~irlift. Well Intake Opening 'Type:. [] Open End' [] Open Hole [] Screened Start · feet Stopped' [] Perforations Start~ feet Stopped Grout Type: bentonite # 8 ...Volu'me: 1 bgs Depth: Start_.O feet Stopped=feet Pump: Intake Depth ~ feet Pump size ~ hp Brand Name Well Disinfected .Upon Completion? [~]. Yes fT] Ne Method of,Disinfection: c/or/no tab/ors.. 'Comments: Well Driller: Alpine DnTling & Enterprises PO/~ox f 10496 Anchorage, .4g 005 ~ ~. Attention: The wall driller shall provide a well log to the property owner within 30 days of completion and the property