Municipality of Anchorage Page 1 of 3
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 Anchorage, Alaska 99519-6650 Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: SW980257 PID Number: 017-112-55
Name:
REED PACKER
Wastewater System: ■ New ❑ Upgrade
Y pg
Address:
15000 GOLDENVIEW DR, ANCHORAGE, AK 99516
ABSORPTION FIELD
Phone:
No. of Bedrooms:
(907) 762-1609
4
❑ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound ■ Other
LEGAL DESCRIPTION
Soil Rating:
2 0
Total Depth from original grade:
1.0' TO 1.2' *Ft.
GPD/sq. Ft
Lot: Block: Subdivision:
Depth to pipe bottom from original grade:
Gravel depth beneath pipe:
TRACT B — PARK HILLS
** Ft.
0.25 Ft.
Township:
Range:
Section:
Fill added above original grade:
Gravel length:
—
—
—
4 Ft.
36 Ft.
WELL:
Grovel width:
Number of lines:
Distance between lines:
❑ New ❑ Upgrade
10.5 Ft.
1
— FL
Classification (Private, A,B,C):
Total Depth:
Cased To:
Total absorption area:
Pipe material:
—
— Ft.
— Ft.
378 So. FL
3/4" SCH 40 PVC
Driller.
Date Drilled:
Static Water Level:
Installer.
OWNER
Date installed:
10/14/98-11/7/98
Ft.
Yeld:
-
Pump Set At
-
Casing Height Above Ground:
-
TANK
GPM
Ft
FL
SEPARATION DISTANCES
❑ Septic ❑ Holding ■ S.T.E.P.
To
Septic
Absorption
Lift
Holding
Public/Private
Manufacturer.
ANCHORAGE TANK
Capacity in gallons:
2000
From
Tank
Field
Station
Tank
Sewer Lines
Well
100'+
100'+
—
—
25'+
Material:
STEEL
Number of compartments:
2
Surface
Water
100'+
100'+
-
-
-
LIFT STATION
Line
10'+
—
—
—
Size in gallons:
Manufacturer.
5'+
2000
ANCHORAGE TANK
5'+
10'+
'Pump on' level at:
Pump- off' level at:
High water alarm at,
1
Foundation
—
—
—
TIMER
TIMER
45"
Curtain
Pump Make do Model:FJectrical
Inspections performed by:
Drain
NO KNOWN
#20—OSI-05-1-11-IFI
M.O.A.
Remarks: * TO THE BOTTOM OF EXCAVATION
BENCH MARK
Location and Description:
** 1.24' TO 2.84' ABOVE ORIGINAL GRADE.
MANHOLE LID
ALL SWING TIES WERE DONE WITH A TOPCON
GT -1003 TOTAL STATION.
Assumed Elevation:
103.14 FL
ENGINEER'S SEAL
oo60p0 �i
o F
v
AWWC, INC.
-
Inspections performed by: Dates: 1st 10/14/98
2nd 11/2/98
i
.........................0
1 1 /�/ss
3rd11/7/98
DO '• J #fr A. Garness:'
Department of Health and Human Services approval
n ,
�" '•• —7953
O 9/iP�• �c00
ooe, ' ••.1.......••' �Ao
Reviewed and approved by: lei tecc, � > C Date: 5 a �`�
�QOa�°rofessiondk
i
t--'�
OQ���pOd
Cv)�L S'-t'-V"ec, c! O-cd2<I �.�{�,
72-013 Rev. 9/91) MDA 25
1 e'Z.,j Cw rU \jcS
0
42 of 42 INSPEC77ON REPORT
MUNICIPALITY OF ANCHORAGE - BUILDING SAFETY DIVISION
3500 EAST TUDOR, ANCHORAGE, ALASKA
(907
INSPECHONS: Voim (907) 563-3464 Fu. (907) 343-8235 INFOXM4770N. )343-82
NAJM.* LEE PACKER PERWTNWBER: 98-082.
ADDRESS. 15000 GOILDENVIEW DR DAM 3/22/00 7:14 Al�
PHONE #1: 244-4623 PHONE #2.-
LOT- BLOCK. TR -13 SUBDIVISION: PARKMLLS
COMMEMS CALL 134 TO LET KNOW WIMN YOU CAN MAKE IT
TYPE OF #2: 03:
INSPEC770N.- Electrical Rough
No non-compliance observed. ❑ Corrections essential as explained below. n C.O. approved.
❑ Will re-munme at next inspection. ❑ Do not conceal until re -inspected. ❑ C.C.O. approved (comments beloi
COMMS MS. -
DAM
WHEN CORAE C-1$ONS ARL AM DE, PLMSE C-4LL FOR IIVSPEMON
DO NOT REAfO VE THIS IVO 77CF-
Municipality of Anchorage Page 1 of 3
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 Anchorage, Alaska 99519-6650 Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: SW980257 PID Number: 017-112-55
Name:
REED PACKER
Wastewater System: ■ New ❑ Upgrade
Y P9
Address:
15000 GOLDENVIEW DR, ANCHORAGE, AK 99516
ABSORPTION FIELD
Phone:
No. of Bedrooms:
(907) 762-1609
4
❑ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound ■ Other
LEGAL DESCRIPTION
Soil Rating:
2.0
Total Depth from original grade:
1.0' TO 1.2' *
GPD/Sq. Ft.
FL
Lot: Block: Subdivision:
Depth to pipe bottom from original grade:
Gravel depth beneath pipe:
TRACT B — PARK HILLS
** FL
0.25 Ft.
Township:
Range:
Section:
Fill added above original grade:
Gravel length:
4 FL
36 Ft.
' . —� (moi--�,�j (� •
VEL
Gravel width:
Number of lines:
Distance between linea:
❑ New ❑ Upgrade
�
10.5 Ft.
1
— Ft.
Classification (Priv a B,C): Total Depth:
Cased To:
Total absorption area:
Pipe material:
— — Ft.
— Ft.
378 So. Ft.
3/4" SCH 40 PVC
Driller. Date Drilled:
Static Water Level:
Installer.
Date installed:
—
_
OWNER
10/14/98-11/7/98
Ft.
Yield:Pump
—
Set At:
—
Casing ' t Above Ground:
TANK
GPM
Ft
Ft.
SEPARATION DISTANCES
❑ Septic ❑ Holding ■ S.T.E.P.
To
Septic
Tank
Absorption
Field
Lift
Station
Holding
Tank
Public/Private
Sewer Lines
Manufacturer.
ANCHORAGE TANK
Capacity in gallons:
2000
From
Well
100'+
100'+
—
—
25'+
Material:
STEEL
Number of compartments:
2
Sur -face
Water
100'+
,00'+
-
-
-
LIFT STATION
LotSize
5'+
10'+
—
—
—
in gallons:
Manufacturer.
P
Line
5'+
10'+
'Pump on' level at: "Pump off"
High water alarm at:
Foundation
—
—
—
Curtain
I
NONE KNOWN
Pump Make e:
FJectrical Inspections performed by:
Drain
Remarks: * TO THE BOTTOM OF EXCAVATION
BENCH MARK
Location and Description:
** 1.24' TO 2.84' ABOVE ORIGINAL GRADE.
MANHOLE LID
ALL SWING TIES WERE DONE WITH A TOPCON
GT -1003 TOTAL STATION.
Assumed Elevation:
103.14 Ft.
ENGINEER'S SEAL
o Op0000O0
......... ... .,....... .,�*.oO�
Inspections performed by: AWWC, INC. Dates: 1st 10/14/98
x—%z c o� 2nd —11/2/98
D
D D
3rd 11/7/98
o. .............o
'.�j�.� r � A. G r SS:
Department of Health and Human Services approval
P PP
13
0 9,� +.•.E-7953 ..:'copy
4�
Reviewed and approved by: _ Date: ��3aProfessio�oo
72-013 Rev. 9/91) MOA 25
PERMIT NUMBER:
SW980257
i
AS -BUILT DRAWING
ST1
103.00
115.93
ST2
114.91
125.88
MHL
116.66
127.23
MT1
227.41
228.59
MT2
233.31
233.73
MT3
240.73
252.02
MT4
235.21
247.40
10' UTILITY EASMENT
PARCEL ID NUMBER:
017-112-55
MT4r-IMT3 NEW BOTTOMLESS I
TH 1 II 'INTERMITTENT SAND FILTER
I I�
I I
MT2L. J MT1 \
TH#24-
ALTERNATE SITE
AIR LINE \
NEW 2000 GALLON x
S.T.E.P. TANK na
cnZ
m$c�
AIR COMPRESSOR
B
DATE:
5/24/2000 OF ,q��j�
i
0
r 1G .. DRAWN BY: QOO
..
ALASKA WATER & WASTEWATER SCALE: J.w M o :' • i*ADD
CONSULTANTS, INC. SCALE: .•
6901 DEBARR ROAD, SUITE 2B • ANCHORAGE, AK 99504' PHONE (907)337-6179 • FAX (907)338-3246 1 = 50 0 ., .............
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
REED PACKER (907) 762-1609 2 OF 3 Q effjj eA.•Garness.:
LEGAL DESCRIPTION: QA 9�..'•• !,' C 7953 0 pO
PARK HILLS SUBDIVISION•' TRACT B V�4s YY,. . •• �cO
TYPE OF WORK: �4�edorofesslo�'O\�
AS—BUILT OF SEPTIC SYSTEM (BOTTOMLESS ISF) ��04poo�oo
PERMIT NUMBER: AS -BUILT DRAWING PARCEL INUMBER:
_
SW980257 017-11 12-55
TOP OF fANK —
Af INI,Ef - 98,60
INVERf OF I3m_
Af 1%1Ef - 96.02
SIDEWALLS OF PLYWOOD WERE
INSULATED WITH 2" BLUEBOARD
aZym
AIR UNE -
FINAL 6P.At7E -102,64 -103,62
5fl 5T2 MN
NSW 2000 GAI.I.ON
WANK
INVI; f OF PIPE -
FINAL 6m -
03 -104,32
2" IN51ATION —\
Mf
— fOP OF TANK
Af OLnrf - 98,59
MOM OF PEA 9AVI IL/
fop OF 5AN17 -101,01
cii i„ ••01
DATE:
5/24/2000
DRAWN BY:
ALASKA WATER & WASTEWATER SCALE: J.W.M.
CONSULTANTS, INC. 1 " = 30'
6901 DEBARR ROAD, SUITE 2B • ANCHORAGE, AK 99504' PHONE (907)337-6179 • FAX (907)358-3246
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
REED PACKER (907) 762-1609 3 OF 3
LEGAL DESCRIPTION:
PARK HILLS SUBDIVISION; TRACT B
TYPE OF WORK:
PROFILE AS—BUILT OF SEPTIC SYSTEM (BOTTOMLESS ISF)
.:.,.A . . ..... .........
• f r�A G ness:
fE —7953 • ticP�
��pro f e s sio�
V11N89'53 O"W 783.45'
r— 206.99' 201.86'
33.24'
WELL 0
0
0
SEPTIC FIELD
cD
co
0 0
178.4
S89*53'50"E 171.54'
783.45'
V) <n SUBJECT
0 PARCEL 0
Zcp
S89*46'29"E
300.44'
(n L4
C)
TRACT B HAS 652542.51 SQ.FT, OF AREA
482.94' X VERTICAL DATUM WAS ASSUMED
8 -
�:-43'39-W NGRAPMC SCAM I hwh - 50 Foot
0
Z
25 12.5 0 12.5 25 50
100
PLOTPLAN ON 5-5-97 W.0-197-270
FOR: Reed & Elizabeth Packer
Date -Sc—ale
5-27-99 1"=50'
Legal Description
FORBES
Lot
BLock
Grid AS -BUILT
Park Hills
PO BOX 112656, Anchorage, Alaska
3137 99-0342
99511-2656
(907) 349-1488
SUBDIVISION
Drawn by Field
Boo
R.J.B. 135
Tract B
I hereby certify that the property described hereon has been surveyed%
by
OF A4 14
me, or at may direction, and that the improvements situated thereon
are within the
property lines and do not overlap or encroach on•
the
property lying adjacent thereto unless otherwise shown. that no
improvements on the property lying adjacent therto encroach on the
in
AW
00
premises question and that there are no roadways, transmission
lines or other easements.an
* -* 49 -TB
said property except as shown.
. . .
.. ..... . ....
It is the resposibility of the owner or builder, prior to construction,
to verity proposed building grade relative to finish grade and utility
00
..... .. .... .... SO
;A 0
10 CHARLES E. FORBES : �'.- 0
connections and to determine the existence of any easements, covenants,
or restrictions which do not appear on the recorded subdivision
#'P . -�.' 00
%# LS -7326
A �' '.
V
plat.
Listed distances prevail over scaling.4W
Reproduction may cause distortion.
'9AW
C-14, 4W
Ofesslo(%
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On-Site Services Program
825 L Street, Room 502
PO. Box 196650, Anchorage, AK 99519-6650
(907) 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Date Issued: Jul 23, 1998
Expiration Date: Jul 23, 1999
Permit Number: SW980257
Legal Description: PARK HILLS TR B
Design Engineer: Alaska Water & Wastewater Services
Owner Name: REED A. PACKER
Owner Address: 10041 HANLEY CIRCLE
ANCHORAGE, AK 99516-0000
Parcel ID: 017-112-55
Site Address: ~GOLDEN VIEW DR
Lot Size: 660360 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] SepticTank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
THIS PERMIT ISSUED FOR THE CONSTRUCTION OF AN ALTERNATIVE WASTEWATER DISPOSAL SYSTEM.
THE ATTACHED PROPERTY OWNER MAINTENANCE AGREEMENT SHALL BECOME A PART OF THIS
PERMIT PACKAGE.
Received By:
Issued By:
Date: 7'-'
Date: 7- ~4-~8
Alaska Water & Wastewater
7320 East Chester Heights Circle - Anchorage - Alaska 99504
(907) 337-6179 N Fax (907) 338-3246
Consulting Engineers
July 16, 1998
Municipality of Anchorage
Department of Health & Human Services
Division of Environmental Services
On-Site Services Sex, ion
P.O. Box 196650
Anchorage, Alaska 99519-6650
Ref: Well and Septic'Design for Tract B, Park Hills Subdivision
To whom it may concern:
The referenced property is currently undeveloped. The owner is planning to construct a 4
bedroom house on .'the site. Comments regarding the proposed well and septic design are
summarized as follows:
GENERAL: Sever, al test holes have been excavated on this property. Due to the presence of
groundwater, the location of surface water and drainage probelems, and the limited area where
suitable soils were found; a innovative bottomless intermittent sand filter (ISF) is proposed to be
installed.
WELL: The existing well is located in the northwest corner of the property.
SOILS: Two test holes were excavated in the proposed area for the septic system. Attached are
the soil logs and pemOlation test results. At the time ofexcavation, groundwater water was found
at 9 feet in both test holes. On 7/10/98, groundwater was found at 4.9 feet in test hole #1 and at
6.8 feet in test hole//2.
SEPTIC DESIGN: Due to the limited area, we are proposing to install a 10' x 36' bottomless
intermittent sand fil~er (ISF) in the Vicinity of TH#1 and TH #2. The following 'is the design
criteria for the primary system.
a. Percolation Rate: <1 minutes/inch
b. Allowable Application Rate for ISF: 4 gallons/day/ft2
c. Number of Bedrooms: 4 (design meets 5 bedroom requirements)
d. Design Flow: 600 gallons per day
e. Minimum Absorption Area: 300 ft2
f. Effective Depth below pressure pipes: 2.5+ inches
g. Width: 10.5 feet
h. Length: 36 feet.
i. Effective absorption area = 360 f~2 (>300 ft2 OK)
j. Air Supply: Thomas Industries, Model 5070, Anchorage Tank .
k. Air Supply Line: W~tasteflow emitterline, 1/2 inch I.D, "Anchorage Tank".
1. Sand Material: Central Paving Products 'W~/inter Road Sand"
m. Pea Gravel: 100% passing 3/8" Sieve, less than 20% passing the 114" Sieve, and
less than 1% passing the #8 sieve.
We are proposing to excavate down to a depth of lfoot (remove all organics), place a minimum
of 2 feet of sand, and-install the ~iir supply line 18 inches below the top of the sand. On top of the
sand, 6 inches of 3/8 inch pea gravel will be placed, with the pressure laterals midway in the
stratum. A conventional lif~ station (Anchorage Tank), equipped with a programmable timer, will
be utilized so that flOw can be intermittently dosed to the ISF.
SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic
system.
TOPOGRAPItY: The lot slopes from east to west at grade of less than 10% (see attached
topography site plan). 'In short, there are no concerns.
MATERIALS AND CONSTRUCTION PRACTICES: The materials used, and the
construction practices will comply with DHHS' "Intermittent Sand Filter Design, Installation &
Maintenance Manual". The contractor should read this document prior to construction. Copies
are available at the Muhicipal Onsite Services office (Sth floor, 9th & L St.).
CLOSING: Given the site restriction, I think the ISF is the most viable option for this lot, short
of install a Recirculating Upflow Filter, which would be more expensive. I am open to any
suggestions from your department, which would be an improvement to the proposed design. I am
unaware of any adv~rse' impacts thiSinstallati°n would'have on adjacent wells or septic systems.
If you have an !questions, please contact me at 337-6179, or 244-9612. Thank you for your
assistance.
Princt
HILLS SUB
WORK:
TE PLAN
FOR:
-_"ED
fAiR LIN£
TRACT
100' OF 3
LOT 11, BLOCK 2, !'c'~' NE 1/4, NE 1/4, NE 1/4, SE 1/4,
~.¢,,~ "~[. .... PARK HILLS S/D #2[ SECTION 34, ml2N, R3W ..~
~ ~ ~ WE LL
EXIST[~ D
NOTE: THERE ARE NO WELLS THAT ENCROACH
UPON THE PROPOSED SEPTIC SY~EM.
~AS~ WA~R & WASTEWA~R
REED PACKER 762-1609 7953
[ NOTE:
I 1. THE CONTRACTOR IS REQUIRED TO NOTIFY THE ENGINEER
I 24 HOURS PRIOR TO CONSTRUCTION,
I 2. THE CONTRACTOR IS RESPONSIBLE FOR HAVING THE NORTH
_j PROPERLY UNE AND THE UTILHY EASEMENT ADJACENT TO TH~I
........... 0 THE NORTH END OF THE PROPOSED SAND FILTER FLAGGEO
BY A REGISTEREO LAND SURVEYOR PRIOR TO CONSTRUCTION.
~_~_ 10' UTILITY EASMENT
LIFT STATION FOR DRAINAGE OF ONE, NO Ld 0
LOW SPOTS WHICH WILL ALLQW WATER TO
COtlECT. ALL CONNECTIONS SHALL BE
STAINLESS STEEL WffH STAJNLESS STEEL
ObJU
~WDS. NO HOSE C~VPS. ~OFOS~P 2000¢¢U. n-mT
NnTES~
THE AIR CDNPRESsnR SHALL lie LDCATEli '~/ITHiN THE
GARAGE/UTILITY RDDN OR CRAWLSPACE, THE CgNTRACTnR
SHALL PRDVInE A 0-10 PS! PRESSURE GAUGE AT A LFICATIDN
WHICH IS REA])ILY ACCESSInLE FRBH ~/ITHIN THE HOUSE,
NDTE~ A 30 PSI GAUGE WILL NOT
THE AIR CrlNPRES-~DR SHALL lie A THDHAS INI)U~'IRIES NDgEL
~070j AS SUPPLIE~I ]~Y ANCHORAGE TANK, THE AIR LINE
SHALL lie 1/~ '~NCH 9IA, 1-19PR (1 PIECE)~ INSULATE9 ~/ITH 1/~
INCH FRIAR PIPE ~*/EAP (R3 VALUE), IN.~[gE ,A B INCH SCH,40
PVC JACKET. THE LINE SHALL lie BtJRtE9 TD ~ HtN[HUH
9EPTH DF 3 FEET,
THE CDNTRrlL PANEL FOE THE STEP TANK SHALL ~E
INSTALLE'rl ~d[TH A AUgIliLE/VI'SUAL INliICATDR V~'THIN THE
GARAGE/UTTLITY
ALASKA WATER & WASTEWATER
PARK HILLS SUBDIVISION, TRACT B,
DESIGN OF PROPOSED SEPTIC SYSTEM
=REPARED FOR: PHONE NUMBER:
762-1609
/7; , , -r ,---
/
P~N VIEW
M~ ~/4" ~d ~A~5 (~,4)~ M~ /~R ~A~
/ N 2' MIN, ~ ~R / /
/
~.'~'~ ~ "' ' . .... ~5;~;
~'~ / PROFILE VIEW
A~S~ WATER ~ WASTEWA~R ~>.~.~~2~
~PE OF WO~:
BOTTOMLESS SAND FILTER (ISF) DETAIL
~.L.M. N.T.S. 3 OF ~ of."s~o~
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
LEGAL DESCRIPTION:
10
11
12
13
14
15
16
17
18
19
20
Co ~.
COMMENTS
DATE
Township, Range, Section:
SLOPE SITE PLAN
was GROUND WATER
ENCOUNTERED?
S
IF YES, AT WHAT q
DEPTH? p
E
Depth to Water After/_ ~, /
Monitoring? "~ ' Date: 7- /
Gross Net Depth to Net
Reading Date Time Time Water Drop
I
PERCOLATION RATE ~ ! (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN '~ FT AND ~ FT
. THAT/THL~q'EST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES iN EFFECT ON THiS DATE. DATE:
72-008 (Rev. 4/85)
PERFORMED FOR:
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
LEGAL DESCRIPTION:
5
6
7
8
9
10
11
12
13'--
14
15
16
17
18
19
20
COMMENTS
~,.'. CJ~ -,9469
~.~/p. ~1~1~ ..'.~
DATE PERFORMED:
Township, ~an~e, Soction:
SLOPE SITE PLAN
WAS GROUND WATER ./
ENCOUNTERED? )~'¢-' '~
S
L
IF YES, AT WHAT I O
DEPTH? Ottl p
E
Depth to Water After Z.~
Monitoring? w, ~) /Dale:
Gross Net Depth to Net
Reading Date Time Time Water Drop
PERCOLATION RATE__ ~-~ / (minutes/inch) PERC HOLE DIAMETER ~ /I
TEST RUN BETWEEN '~ FT AND /~ FT
PERFORMED BY: .... / I CERTIFY THAT~tIS./T~_ST WAS PERFORMED IN
ACCORDA.OE, ,T.^.LSTATEA.DM .,C,PA'G 'DE""ES'"E EOTO"T"'SDA E. DA E:
72-008 (Rev. 4/85)
PROPERTY OWNER AGREE1VFENT
FOR THE MAINTENANCE OF AN
ON-SITE WASTEWATER DISPOSAL
SYiTF2Vl
ThLq agie~2m~nt, dated .~q~-y ~25// 199~'.., is ~e be~e~ ~e Mu~!cip~ of
~chorage D~ent of He~ ~d Hnm~ Se~iccs.~S) ~d ~e prop~
o~) oe
ThLs agreement Ls made for ~c purpose of m.lntalning all on-site w~stewater disposal
system On ~e subject property.
The property owners o~ee to fi]e, following:
Submit to ~e Municipality of A~chorage, on a~ annual basis, an inspection and
operation statement from a registered professionul engineer, TI~ impection a~d ..
operation statemem shall verify ~at ~e engLueer has in~pected all effluent and air
p-raps, timers, ~ud alarm~, and that ~uy deficiencies have been repaired ant[ that the
system Lq functioning a~ designed.
.... / ( (Signamr¢)
(Sig~=e)
/~o /52,
(Printed N,me)
......... No'~arlze Here
who is personally kno~ ~o me
1:6 be t:b.e
(Prated Name)
, , lqqg
whose identity I proved on the basis of
"-- whose identity I proved on the bath/affirmation of
, a credible witness
signer of the above doeumen=, and he/she acknowledged that he/sh9 signed f~.
October 9, 1998
Municipality of Anchorage
Department of Health and Human Services
On-Site Services Program
825 L Street, Room 502
P.O. Box 196650
Anchorage, Alaska 99519-6650
Re:
Permit Number SW980257
Tract B, Park Hills Subdivision
15000 Goldenview Drive
Gentlemen:
I would like to obtain your permission to do an owner installed wastewater disposal
system. I am the owner of the above referenced property. Scott's Trucking will be
assisting me with the excavation work.
I am acting as the general contractor for the construction of my new residence. I have
previously worked for five years as a general contractor in Southern California and
have direct experience with installing plumbing, sewer pipe and irrigation systems. 1
am currently installing the radiant heating system at 15000 Goldenview. For the
installation of the on-site wastewater disposal system, I will be working closely with Jeff
Garness and Jim Williams to obtain the necessary inspections and to insure that the
system is properly installed.
Please let me know if you approve this request.
Reed A. Packer
10041 Hanley Circle
Anchorage, Alaska 99516
cc: Alaska Water and Wastewater Services
05/22/01 FRI 09:33 FAX I 907 ?62 163! VECO ENGINEERING-PROJECT {~001
M-W DRILLING, Inc.
P.O. Box 11037~ · 10330 Old Seward H~ghway
(907) 349-8535
ANCHORAGE. ALASKA 99511
Well Owner
DEll. UNO LOG
Use of WellEXPLORATORY
Depth in feet from
ground surface
fl TO ?
? ~0 4
4 ~0 7
7 TO 32
32' TO 37
37 TO
59 TO 62
62 TO 7)
73 TO
BO TO 82
R? TO q5
95 TO 102
102TO 122
l~2TO 128
Location (address of: Township, Range, Section, if known; or distance main road
TRAt~T R: PARKHI!I SUBDIVISION
ROt DEN VIEW SCHOOL SITE: ANCHORAGE. ALASKA
Size of ca~ing 6" l~epth of Ho)~ 128 feet Cased t- 128.87 feet
Static water leve] 4 fL (~l{)?: ?elow) land surface. Finish of well (check one) open end ( );
Screen ( X ); Perforated ( , ~)~,
Describe screen or perfotaUon "" {{ER:ATTACHED AS BUILT SKETCH
Well pumping test at ?n gall~l~s~.....~.,Pel~,.~.. ) (minute) for 74 hours wit}, 36.5 ft.
of
drawdown
from
static
~el,~.{~ '~:- AS BUILT NOTES: 1) DRILLED 14 DECEMBER
· ~r.~ ..,u~ ' 2) COMPLETED AN0 TESTED 15 SEPTEMBER 198:
Date of completion IEE NOTES !,,Y '.,' -
G~ve d~tAlls of formations penetrated, size o! material, color and hardness
CASmG ST CZ UP
GRAV[[LY FILL
OR,RANTK.~OV~RBURD£N
,~ND~?AND GRAVEL: TAN, DAMP.. .
mm
GRAV El'. *.DAH P .... ~ , ....... ~- .....
GJ~AVEL HARDPAN :/~AH
SAND AND GRAVEI~?'NATERBEARING
~[LTY GRAVEL AND CLAy;
SAND AND GRAVEL: 14ATERBEARING
GRAVEL AND CLAY: GREY'? SILTY'
SAND AND GRAVEL: ~ATER BEARING
~RAyEL AND CLAY: TAN, SILTY
1 --CUSTOMER
Municipality of Anchorage
Development Services Department
Building Safety DMslon
On-Site Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.d.anchorage.atcus.
(907) 343-7904
CERTIFICATE OF HEALTH ,UTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 017-112-55
1. GENERAL INFORMATION
Expiration Date:
complete legal description
Location (site address or directions)
Current Property owner(s)
Mailing address
Lending agency '
Mailing address
Real Estate Agent
Mailing address
PARK HILLS SUBDIVISION; TRACT B
15000 GOLOENVIEW DR., ANCHORAGE, AK 99516
REED PACKER Dayphone (907) 762-1609
15000 COLDENVIEW DR, ANCHORAGE~ AK 99516
Day phone
Dayphone
Unless otherwise requested, HAA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 4 ·
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
TYPE OF WASTEWATER DISPOSAL:
Individual On-site E~
Individual Holding tank
Community On-site D
Public Sawer [-]
The Munlclpality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given In paragraph 5 by an Independent professional civil
engineer registered In the State of AJaska. Certificates of Health Authority Approval are required for the transfer
of title (except between spouses) for properties served by a single family on-sita wastewater disposal and/or
water supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a pedod of
up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B
wells or a public water system. The Municipality of Anchorage Is not responsible for errors or omissions In the
professional engineer's work.
Note: Alaska Water and Wastewater Consultants, Inc. shaft be paid $ 00.00 at, or prior
to closing for the engin~erlng servfcea provided.
4. STATEMENT OF INSPECTION BY ENGINEER
As ce~'fied by my seal affzxed hereto and as of the validation date shown below, I vedfy that my
investigation, based on procedures outlined in the Health Authorffy Approval Guidelines for this application,
shows that the on-site water supp~/ and/or wastawater disposal s~tem Is(are) safe, functiooal and adequate
for the number of bedrooms and ~ of structure Indicated herein. I further vedfy that based on the
information obtained from the Munidpali~y of Anchorage files and from my investigation and Inspection, the
on-site water supply and/or wastewater disposal system Is(are) in compliance ~th all applicable Municipal
and State codes, ordinances, and recjulations In effect at the time of installation.
Name of Firm ALASKA WATER &: WASTE'WATER CONSULTANTS. INC. Phone
Address 6901 DEBARR ROAD. SUITE 2B * ANCHORAGE, AK 9950~-
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
Date
337-6179
Engineer's Comments:
In conducting this evaluation, AWWC, Inc. attempted to provfde a thorough,
consdentious euglneedng ana~sis of the system in accordance wllh ADEC and MOA
DSD Guidelines & R~gulatioes. The reported results desctfbed the performance of the
system under the conditions encountered at the time of the test, and soparaEa3
d/stances measured to readi~ ldentifiable foateres. The operational life of a~l wells and
septic systems depend on the local enEs condition, groundwater levels that may
fluctuate during the year, and the tire tar usage of the fam/¥ being sen/ed by the system.
These conditions are outside the control of the evaluator of the system. ~atisfactory test
results do not guarantee future performance of the system, nor do they guarentoe that
there are no hidden defects or encroachments. AWWC, Inc. can therefore not provide
any v,.arranty or lucre estimate of how long the system will conb'nue to meet the
operational requlrements of the ADEC or MOA DSD. The content of this report Is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or perty Is not authorized, nor will it confer any lugal tfght whatscev~r.
DSD SIGNATURE
/,,'""" Approved for ~ bedrooms.
Disapproved.
Conditional approval for __
Attachments:'
NM Checklist
Septic System Advlso~
Well Flow Adviso~
Manitenance Agreements
Supplemental Engineer's Reort
Other
Odglnal Certificate Date:
Municipality of Anchorage
Development Services Department
Or-,-Slte Water & Wa~ewater Pmgnlm
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519.6850
Legal Dascflpllo=
WELL DATA
Well ~ pRIVATE IIt A, B, er C provide PWSID# N/A
Oatacompleted 12/21/81 Sanltmyseal(Y/N)YES
Total depth 128 It. Cased to 128.87 ft.
Data of test
Static: water level
Well preductlon
WATER SAMPLE RESULTS:
HEALTH AUTHORITY ~,PPROVAL CHECKLIST
PARK HILLS SUBDMSION; TRACT B Pat'collD: 017-112-55
Date Installed ~l~,/~s 6o~ rating ~ ~redrm) 2.0
Length 56 It. Wldlh 10.5 lt.
Total depth 3 lt. Eft. absorp8on sma 578 It' Monitoring tube YES
Date of adequacy test. NEW~ I?d~sul~ (Pass/Fall) --
Fluid depth In abserpfion field before test DRY In.
E]apeed Time: - min. Final fluid depth - In.
Any reJuvanallon ~eatrnsnt (past 12 mo.) (Y/N & type) -
*HOUSE NOT OCCUPIED UNTIL 4./1/00
Wataradded - g~.
PBD. OW fiNN. GRADEI
Coliform ~ colonies/100 mi. Nitrate
Date of ~ample: 6/21/01 Collected by:.
B. 8EPTIC/tiOLDING TANK DATA
Tank Type/Matarlal S.T.E.P./STEEL
Tank elze 2000 gal. Number of Comparlmants
Foundation cleanout (Y/N) YES
Date of pumping 6/25/01
D. ABSORPTION FIELD DATA
2
Depression over tank (Y/N) NO
Pumper
Well Log (Y/N)
W~ms pmpe~y protected (Y/N).
Casing height (above gmur~)
AT INSPECTION
6/21/2001
29 lt.
12.1+ g.p.m.
18+ In.
Other bectada _~colonles/l(X) mi.
AWWC, INC.
Date Installed 11/7/98
Qeanouta (Y/N) YEs
High water alarm (Y/N). YES
A+ HOME SER~CES
System t~q)e ISF
Gravel below pipe 0.25 ft.
Depres..~on over field NO
For 4 bedrooms
Newdepth - In.
Absorption rate >- - g.p.d.
If yes, give data -
FROM WELL LOG
12/21/81
20 g.p.m.
D. UFT STATION
Datalnstailed lO/14/9~ 8izelngallons 2000
· Pump on' level et..]]~E~_ln. 'Pump off' level ~,! TIMER In.
Datum eo'rroM QF TANK Cy~tes ~ 3
E. $£PARATION OISTANCF.~
SEPARATION DISTANCES FROM V~.LL ON LOT TO'
Septic tanlallff etal]on on lot 100'+
Absoq~on field on lot. 100'+
Public sewer main N/A
Sewer ISel~O ~eMce line 25'+
Manhole/Access (Y/N) YES
High water alarm level at 45'
Meets alarm & circuit requirements? YES
On ao']acent lots 100'+
On adjacent lots 1 oo'+
Publlo ~wer manhole/cteanout
Holding tank N/A
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Abeeq~tlon field. 5%
Surface water, lOO'+
Building foundation 5'+ Property line 5'+
Water main N/A Water service line. 10'+
Wells on adjacent lots 100'+
SEPARATION DISTANCE FROM ABSORPTION fiELD ON LOT TO.'
Bul]dlng foundation 10'+
Surface watsr 100'+
Wells on adjacent lots, ~00'+
Property I~ne lO'+
Water aenace line 10'+
Curtain drain NONE KNOWN
F. COMMENTS
Water main N/A
Driveway, perldng/Vehlcle storage
50'+
G. ENGINEER'S CERTIFICATION
I certify that I have determined t~h field In~cectlons end
cor~rmance valh MOA HAA guidelines in effect on this date.
Englrleel'sPrln~lN~fne JEFFREY A. GARN~
HAA Fee $ ~DD. O0
Data of
Receipt Number
(aw, t2/oo)
Waiver Fee $,
Date of Payment,
Receipt Number