ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: .~ t,.~O/O ~ Z.,,~' PID Number:
~'~° ~tr'.y ~',.T¢rr'; ~o?~,~' Wastewater System: [] New [] Upgrade
'~"" 30¥~ ZS~lcl4eo De"t,,'¢~ A'~-~' J'9,¢1"/ ABSORPTION FIELD
LEGAL DESCRIPTION ~. 8
O..P ~,. ¥~'
Well: [] New [] Upgrade ~ ~,.1
od ,..I ,.r ,, TANK
SEPARATION DISTANCES E]$e¢ic D.o~ding I~S.T.E.e. l--lOther:
Tank Field station Tank Se,~ver Line ~-/1 ~-1~O O
w,., II1' I1~'° Ill' - ~_5'~ _~t~&/
~V/ ~,~ LIFTorf.~coSTATION
,~.~,,~ ~ ~ "32 37. - '~ Z. ,, I
".'".". BENCH MARK
£ngineer'$ $~amp
Inspections pedormed by: F~R~p ~ ~c Dates: 1*= V/Ib{ol
Developme~~~Approval
Reviewed an~ approved by: ~ Y' I~ Date: //-~¢
/ · 'to:
~ ~ TR. C.O. "C" 49' 44.5'
/~ TR. M.T. "D" 86' 72.5'
~ TR. C.O. "E" 102' 89'
WELL ~ TANK C.O. "F" 52' 36'
j ~/ LIFT M.H. "G" 62' 44'
LOT 6, BLOCK 1
.... '--.....TUXEDNI.. PARK
"~ " 1500-G~LLON
", ", STEP TANK
", ~ TJ'L
FOUNDATION
rBM
-C#
48-FOOT LONG
ABS. TRENCH
W. 8.2' EFF. GRAVEL
EII
PERMIT NO: SW010225 PAGE 3 OF 3
PID NO: 041-022-08
~- GROUND ELEV @ T.H.#1 = 87.7'
, , 2' SOIL COVER
4'+ SOIL COVER: , , 2" RIGID INSULATION
95.1', 95.1'
' ' TRENCH
92.4 92 3' ,, 46-FOOT LONG SOIL ABS. ', ',.
.... ~ ' ' EFFECTIVE GRAVEL !
............................. , ,, WITH 8 2' ' '
1500-GALLON STEP TANK ,,
" __~
,' ,' soTroM EXCAVATION ELEV. 86 .9'
'
::
BOTTOM T.H.#1 ' ' ~ ":' '. : '~' '"'
ELEV, 7g.2' . . ,s .,, .. · · ~,~,' z~
LOT 6, BLOCK 1, TUXEDNI PARK S/D
SEPTIC SYSTEM INSTALLATION
AS-BUILT PROFILE
FLATTOP II,ClINICAL SEP. VICE$ NOT TO SCALE
14~30 £C110 STP. E£T DRAWN BY TFM
ANCl IOPJ~O£,.AI~SY.~ ggSI6 SEPTEMBER, 2001
CIVIL& EN~ONMENTAL ENGLNEER~G * ENERGY CONSERYA'I1ON & AN.4~LY$~
TItEODORE F. MOORE, P.E. 14530 ECHO ST.
PH: (907) ~45-1355 ANCHORAGE, ALASKA 99516
September 26, 2001
On-site Services
MOA DSD
P.O. Box 19-6650
Anchorage, AK 99519
Re: Lot 6, Block 1, Tuxedni Park - Septic System Installation construction notes - Permit # SW010225
Dear Sirs:
Prior to and during construction of the wastewater disposal system on the subject lot monitoring of
test hole # 1 demonstrated the absence of groundwater to a depth of 18.5 feet. Thus we were surprised
when the excavator encountered a pocket of saturated soils at a depth of 11 feet at .the southeast end of the
trench less than 30 feet from the test hole monitor tube. This moisture was apparently perched on a
concave lens of dense silt. We endeavored to stay away from this wet area by slightly raising the bottom
of the trench and shifting the end of the trench a little to the northwest. Nevertheless, one day after trench
was completed we observed a temporary buildup of 2-3 inches of water in the trench monitor tube, which
has since dissipated. The presence of this water was of sufficient concern that I called Jim Cross and
requested a site meeting, which took place on Suly 23. Jim concurred that the nearby much deeper and
dry test hole monitor tube demonstrated that the small amount of moisture encountered should not be
classified as groundwater, and said that the Department would approve the trench as installed.
Also, part way through construction it became apparent that the homebuilder was not happy with
the floor elevation necessary to allow gravity flow into a conventional septic tank. Accordingly, I spoke
with Dan Roth and obtained verbal approval to switch out the original 1250-gallon septic tank for a 1500-
gallon STEP tank. The 1.25-inch diameter pressure discharge line was plumbed into the already installed
4-inch diameter gravity distribution pipe. The electrical inspection for the lift station was scheduled to be
accomplished in conjunction with the regular electrical inspections for the remainder of the house.
Please feel free to give me a call ifyou have any questions.
Sincerely,
Ted Moore, P.E.
Municipality of Anchorage
Department of Health and Human Services
825 'L' Street
P.O. Box 196650 Anchorage, ^laska 99519-6650
Rick Mystrom htr p:l/www.ct.anchocage.ak.us
Mayor
Permit Number:. #SW.010225 Date oflssue: 7-6-01
Date Started: 7-29-01 Date Completed: 7-29.01
Legal D~scdption:
Property Owner Name & Address:
Bo. rchole .D. ata:
Soft Type, Thickness & Watc~ S~ata
stick-up
organic 8, silt
silty gra vel
gravelly silt
silty gravel
water sand 8, gravel
Parcel Identification Number:. 041-022-08
ls well located at approved permit location? [] Yes [] No
.Tuxedni Park BIk 1 Lt 6
Gary & Je~{Soper
3048 Balcl~-bh Dtfve
Anchorage, Ak 99517
Depth (ft)
From To
0
2 4
4 23
23 54
54 80
80 88
Method of Drilling [] ah'rotary [] cable tool
Casing type: steel
WallThickncss: .025 inches -
Diameter: 6 inches Depth: ~ feet
Liner Type:
Diameter:. ~ inches Depth: ~
Casing stickup above ground: _2 feet
feet
Static water level (~om ground level): 33 feet
Pumping level: 86 feet after
_2 hours pumping 8 gpm
Recovery Rate: _.8 gpm
Method of Testing: air l~
Well Intake Opening Type:
[] Open End [] Open Hole
[] Screened Start__ feet Stopped -- feet
[] Perforations Start__ feet Stopped feet
Grout Type: Bentonite # 8 Volume: 1 bg
Depth: Start_0 feet Stopped_+ feet
-Pump: Intake Depth feet
Pump size hp Brand Name
Well Disinfected Upon Completion? [] Yes [] No
Method ofDisinfectlon: Clorfne Tablets
Comments:
Well Driller: Alpine Drflling & Enterptfses
P 0 Box 110496
Anchorage AK 99511
At~ention: The well driller shall provide a well log to the property owner within 30 days of completion and the property
MUNICIPALITY OF ANCHORAGE
Development Sen/ices Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
7~fl/z) ! I I
ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT
Initial
Date Issued: Jul 06, 2001
Expiration Date: Jul 06, 2002
Permit Number: SW010225
;Legal DescripUon: TUXEDNI PARK BLK I LT 6
Design Engineer: 0019 Flattop Technical Services
Owner Name: Gar~ & Jerri Soper
Owner Address: 3048 Balchen Dr.
Anchorage, AK 99517-
Parcel ID: 041-022-08
Site Address:
Lot Size: 90894 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit Is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
D, te:
Date:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P,O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWEPJVVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D.
Permit Number,SWO.~
Property owner(si
Mailing address (1)
Day phone
Mailing address (2) /~ ¢-.~'~'~'~. ~
Legal description (Lot, Block & Sub'd.) L~>'~ ~
Legal description (Section, Township & Range)
Lot Size 9,O~o~'~ Acres/Sq. Ft. Number of Bedrooms
Zip Code <~,.¢t '7
THIS APPLICATION IS FOR:
Sewer Only
Sewer and Well
Sewer Upgrade
THIS PROPERTY CONTAINS:
Hot Tub
Swimming Pool
Therapy Pool
[] Well Only []
[] Water Storage []
~[] Jacuzzi
Water Softening Unit
I certify that the above information is correct. I further cedify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit Fees:
Date of Payment:
Receipt Number:
(Rev. 12/00)
Waiver Fees:
Date of Payment:
Receipt Number:
CIVIL& ENVIRONMENTAL ENGLNEERLNG · ~GY CONSERVA~N · ~
~O~RE F. MOORE, P.E. 14530 ECHO ST.
PH: ~07) J45.135S ~CHO~GE. ~KA 99516
June 22, 2001
M.O.A. DSD
P.O. Box 19-6650
Anchorage, AK 99519
Dear Sirs:
The purpose of this letter is to provide the required design narrative in support &our application for
a permit to construct wastewater disposal facilities on Lot 6, Block 1, Tuxedni Park S/D, located at 9600
Chenega Drive Soils logs, pert test results, a site plan, design drawings and specifications are enclosed
for your review.
The proposed system will be constructed in the vicinity ofte~t hole # 1. As ca~ be seen from the soil
log, the native material between 1' and 18.5 feet is a mixture of sands and gravels, with occasional
lenses &silt. Although the measured pete rate in the pere test hole was << 1 minute per inch, I have
used 0.8 gpd/square foot as an overall soil application rate to compensate for the expected erratic silt
lenses that will be encountered in the trench. The presence of predominantly sand material below 11
feet will ensure adequate filtration without installation of imported filter material. Using a soil
application rate of 0.8 gpd/sq, ft., this 4-bedroom residence requires a total absorption area of(4 x
150)/0.8 = 750 square feet. The proposed 42-foot long trench design with an effective gravel depth of
9.0 feet has a total absorption area of 756 square feet.
The topography of the lot in the area &proposed construction slopes gently towards the southeast at
approximately 3%.
The proposed project will have no significant impact on present or future water supply and
wastewater disposal systems serving adjacent properties, nor will it have any significant impact on
reserved space-surface and subsurface, or on drainage.
Please give me a call at 345-1355 if you have any questions on, this submittal.
Sincerely,
Ted Moore, P.E.
SEPTIC
LOT 5
R 100'
PROPOSED
WELL
PROPOSE°
EXIST. ·
WELL'S., ', ',, ' T.H.
__~ ,, ~ #2
LOT 9
LOT 6, BLOCK 1
TUXEDNI PARK
INSTALL 1250-GALLON
SEPTIC TANK
CONSTRUCT 42' LONG
SOIL ABS. TRENCH
W. 9.0' GVL. BELOW
DISTRIBUTION PIPE
SEPTIC / ' '
/ LOT8 ',,~',,,, ~
AREA
OF
~;~ ....... ~ ;% ~ k ',
358?
#1
SffE FOR LOT 7
REPL. TR. ..o ........ ,
SEPTIC ~ X~ WELL
,; /
LOT 6, BLOCK 1, TUXEDNI PARK S/D
PROPOSED WELL AND SEPTIC SYSTEM
SITE PLAN
FLA'rI'OP T[CIINICA~ SER¥]CES J 1 INCH = 70 FEET
14530 ECIIO STI~ET J DRAWN BY TFM
ANCl lOP, AGE, ALASKA 99S I 6 JUNE, 2001
NOTE: THIS IS NOT A SURVEYED PLAT.
ALL LOCATIONS SHOWN ARE APPROXIMATE.
.~..~. _ 4" DIA~ ASTM D-3034 WASTE LINE FROM HOUSE
1250-GALLON SEPTIC TANK 42-FOOT LONG SOIL ABS. TRENCH
"A" ~ ~ WITH 9.0' GRAVEL BELOW DIST. PIPE
"A" L~. ' ' ~ 4" DIA~ F-810 PERF PIPE
PLAN VIEW
SCALE: 1" = 10'
MONITOR TUBE
CLEANOUT
MOUND BACKFILL
ORIGINAL GROUND
-- FILTER FABRIC
-- 4" DIA~ F~10 PERF. DIST. PIPE
! lfZ' SEWER GRAVEL
BOTTOM OF EXCAVATION
CROSS-SECTION "A - A"
SCALE: 1" = 5' - 0"
LOT 6, BLOCK 1, TUXEDNI PARK S/D
SEPTIC SYSTEM DESIGN
PLAN AND CROSS-SECTION
FLATroP TECI INICAL SERVICF_.S
14530 ECilO STREET
ANCI IORAGE, AK, 99516
SCALE: AS SI IOWN
DRAWN BY: TIM
JIJ~, 2001
q:fattop 'Tecllnicaf Serviees
14530 ~Ecilo Street, ~Incllorage, ~ 99516
~'fwne (907) $45-1555
Lot 6, Block 1, Tuxedni Park S/d
9600 Chenega Drive
Wastewater disposal system installation
Specifications
1.0 General:
1.1 The scope ofthe project consistsofinstallationofa 1250-gallon septic tank that discharges
effluent into a 42-foot long soil absorption trench with a total of 9.5 feet of sewer gravel.
1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor
deviations from these drawings may be allowed or required by the engineer conducting the inspections.
All construction procedures and material specifications shall conform to Municipal and State
requirements. All separation distances shall be in conformance with Municipal requirements, unless
specifically waived.
1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around
any buried utilities.
1.4 The contractor shall provide adequate cover material and rough grading over all system
components to ensure that proper drainage is achieved after settlement and that there are no residual
depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas.
1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading
after the soil is compacted, as well as placement of topsoil and reseeding all areas disturbed by the
construction.
2.0 Septic Tank:
2.1 The new 1250-gallon, 2 compartment septic tank shall be Municipally approved and shall be set
level on undisturbed soil. Each compartment shall be equipped with a watertight manhole cover and a
4" cleanout. Ifthe tank is buried less than 4 feet, it shall be insulated with 2 inches of approved burial
type, rigid insulation.
2.2 All pipe connections to the tank shall be equipped with waterproof mechanical couplings. The
waste line from the residence to the septic tank shall have a minimum slope of 1/4'" per foot, and the
waste line between the tank and the soil absorption system shall have a minimum slope of 1/8" per foot.
A cleanout shall be installed within 5 feet ofthe building foundation, and a double cleanout shall be
installed within 5 feet downstream of the septic tank.
3.0 Soil nbsorption system:
3.1 The soil absorption system shall be constructed by excavating a 42-foot long trench to a depth of
12.5 feet below ground elevation in the vicinity of test hole Itl.
3.2 The bottom ofthe excavation shall be level. Any compacted or smeared surfaces shall be raked
to allow proper infiltration.
3.3 A total of 9.5 feet of approved sewer gravel shall be placed in the bottom of the excavation with
the perforated distribution pipes laid level such that the pipe inverts are no less than 9.0 feet above the
bottom of the sewer gravel. Sewer gravel shall be 0.5" - 2.5" screened gravel, with less than 3% passing
the It200 sieve.
3.4 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations shown on
the design drawings. The portion of the monitor tube extending through the sewer gravel shall be
perforated.
3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel. A
minimum of 2 feet ofsoil cover is to be placed over the filter fabric. If the soil cover thickness is less
than 3 feet, two inches of rigid, burial type insulation is to be placed over the entire top surface of the
gravel, in addition to the filter fabric.
3.6 The top surface of the cover material shall be raised a minimum of 6 inches higher than the
surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contours. Fill
slopes shall be no steeper than 3:1.
3.7 Unless specifically agreed otherwise the homeowner shall be responsible for arranging to have
the site finish graded after the backfill material has stabilized, and for placement of adequate topsoil and
seed to promote rapid revegetation ofall areas disturbed by the construction.
4.0 Inspections:
4.1 A minimum of 4 engineering inspections will be required during the course ofthe project: (I)
initial stakeout with the contractor to establish the location ofthe system and to discuss the plans,
specifications and construction procedures, (2) after the native material has been excavated to expose the
infiltrative surface to ensure that it is level and at the right elevation, and conforms with the soil test
information, (3) after the sewer gravel is in place and the distribution pipes have been laid and connected
up to the septic tank, but prior to placement of insulation or filter fabric, and (4) after rough backfill and
grading is complete. The septic tank requires one inspection after it is set level and the piping
connected, but prior to backfill. This inspection may be incorporated with any of the above inspections.
4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in
advance to ensure the availability ofthe engineer.
ITESTHOLE#!
LEGALDESCRIPTION:
DATEPERFORMED:
PERFORMEDFOR:
(feet)
2-
3-
4-
I
Lot 6, Block 1, Tuxedni Park SE)
May 23, 2001
Gary and Jerri Soper
GW Cleansandygravel
FLATTOP TECHNICAL SERVICES
14530 ECHO ST.
ANCHORAGE, ALASKA 99516
SOILS LOG -- PERCOLATION TEST
SLOPE
SITE PLAN
SP Clean medium sand
ML Gravelly silt
GM Silty gravel
SW/GW Clean Sand
gravelly, with
pockets of ML
Depth to Groundwater Date
~___~o_groundwater 5/23101
Omtor~be dry 6/4/01
Monitor tube dry ~0/01
Clock Net Time Percomater Net Drop
Date Reading Time (minutes) Reading (inches)
{~/23 17' presoak 27--3_/8
Resoak 273/8
Add water & start 4:13Z55 23_3/8
#1 4:15~55 2 18_3/4 4 §/8
Add water 4:16Z20 23 3/8
#2 4:18:20 2 18~18 4 1/2
Add water 4:18:45 23-;172
#3 4:20~5 2 19T/8 4 3~
PERCOLATION RATE <<1 (minutesAnch) PERC HOLE DIAMETER 6"
TEST RUN BETVVEEN 6.5 FT AND 7.0 FT
COMMENTS: Soil strata encountered in test hole(s) were highly variable, but generally very good for on-sEe soil abs. systems.
Despite high perc rate, no need for sand filter due to u*ndedying sand. Recommend using 0.8 ~l:xJ/sq. ft. overall to comp. for sitfier strata.
PERFORMED BY FLATTOP TECHNICAL SERVICES. I ,~..~ ~ CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~/~ 2../~,f,
ITESTHOLE#2
FLATTOP TECHNICAL SERVICES
14530 ECHO ST.
ANCHORAGE, ALASKA 99516
SOILS LOG -- PERCOLATION TEST
LEGAL DESCRIPTION: Lot 6, Block 1~ Tuxedni Park S/D
DATE PERFORMED: May 23, 2001
PERFORMED FOR: Gary and Jerfi Sopef
DEPTH ~
(feet) PL
4-
5
6-
7-
8-
SM Silty loam
SP/GP Gravelly sand
ML./GM Gravel/y silt
GP Clean black sandy gravel
SLOPE
T.H.__
#1
T.H. ~O
#2
COMMENTS:
GM Silty gravel
Depth to Groundwater Date
__No_groundwater 5/23101
Monitor lube dry 6/~0/01
o.
OP Silty sandy gravel
Clock Net Time Pemometer Net Drop
Date Reading Time (minutes) Reading (inches)
PERCOLATION RATE
(minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN F-rAND FT
No percolation test conducted because the matedal in this test hole appeared sligh_tly less desirable than in test hole #1.
PERFORMED BY FLATTOP TECHNICAL SERVICES. I ,~*~.~ ~ CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ,~'/T.. ,?. / ~/